Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 449
Filtrar
1.
J Soc Cardiovasc Angiogr Interv ; 3(4): 101347, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39130173

RESUMEN

Transcatheter tricuspid valve replacement (TTVR) offers the potential for improved outcomes for the significant number of patients with severe tricuspid valve regurgitation relative to current treatment options. Imaging is a critical component of the success of this procedure. Here we describe strategies and techniques for the use of 3-dimensional intracardiac echocardiography as an adjunct to standard transesophageal echocardiography during TTVR procedure.

3.
J Clin Med ; 13(15)2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39124831

RESUMEN

Background: Atrioventricular node (AVN) ablation is an effective treatment for atrial fibrillation (AF) with uncontrolled ventricular rates despite maximal pharmacological treatment. Intracardiac echocardiography (ICE) can help with visualizing structures, positioning catheters, and guiding the ablation procedure. We compared only fluoroscopy-guided and ICE-guided AVN ablation regarding patients with permanent AF. Methods: Sixty-two consecutive patients underwent AVN ablation were enrolled in our retrospective single-center study (ICE group: 28 patients, Standard group: 34 patients). Procedural data, acute and long-term success rate, and complications were analyzed. Results: ICE guidance for AVN ablation significantly reduced fluoroscopy time (0.30 [0.06; 0.85] min vs. 7.95 [3.23; 6.59] min, p < 0.01), first-to-last ablation time (4 [2; 16.3] min vs. 26.5 [2.3; 72.5] min, p = 0.02), and in-procedure time (40 [34; 55] min vs. 60 [45; 110], p = 0.02). There was no difference in either the total ablation time (199 [91; 436] s vs. 294 [110; 659] s, p = 0.22) or in total ablation energy (8272 [4004; 14,651] J vs. 6065 [2708; 16,406] J, p = 0.28). The acute success rate was similar (ICE: 100% vs. Standard: 94%, p = 0.49) between the groups. Conclusions: In our retrospective trial, ICE-guided AVN ablation reduced fluoroscopy time, procedure time, and first-to-last ablation time. There was no difference in ablation time, total ablation energy, acute and long-term success, and complication rate.

4.
Heart Rhythm ; 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39053753

RESUMEN

BACKGROUND: Although the electrcardiographic and electrophysiological properties of ventricular arrhythmias (VA) from the vicinity of lateral tricuspid annulus (TA) have been reported in previous studies, their precise site of origin have not been addressed. OBJECTIVE: To describe the precise origin of lateral TA-VA and the relevant anatomy. METHODS: Consecutive patients with idiopathic lateral TA-VAs were reviewed and analyzed. Three-dimensional mapping system combined with intracardiac echocardiography (ICE) was used for anatomical reconstruction, mapping, and ablation. RESULTS: During the study period, 63 patients with lateral TA-VAs were included. Under ICE view, a prominent enfoldment structure was observed under the valve along lateral TA. The muscular bundle was documented in all patients (100%) within the sub-valvular enfoldment with an average number and diameter of 4±2 and 4.10±0.73mm, respectively. Initial ablation was attempted via the antegrade approach in 15 patients but succeeded in none. To reach the ventricular side of TA, the catheter needed to enter ventricular chamber and retroflexed toward the atrial side with a reverse curve. The earliest activation site was found at the valvular end of muscular bundles in 51 of the 63 (80.9%) patients with a local activation time of -26.78±4.63ms. The VAs were eliminated after an average of 4±2 seconds of ablations. CONCLUSION: The ventricular adjacent to the lateral TA exhibits a sub-valvular enfoldment-like structure, which is rich in muscular bundles and serves as the origin of TA-VAs in most patients. To reach the origins, a reverse technique is required.

5.
Rev Cardiovasc Med ; 25(6): 191, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39076314

RESUMEN

Researchers have investigated ways to develop optimal imaging techniques to increase the safety and effectiveness of electrophysiological (EP) procedures. Intracardiac echocardiography (ICE) is an advanced imaging tool that can directly visualize cardiac anatomical structures in high resolution, assess tissue heterogeneity and arrhythmogenic substrates, locate intracardiac catheters, monitor catheter-tissue contact and ablation injury in real-time, excluding intracardiac thrombi, and quickly detect procedural complications. Additionally, real-time imaging via ICE can be integrated with a three-dimensional (3D) electroanatomical mapping (EAM) system to reconstruct cardiac anatomy. This technique also promotes the development of zero-radiation EP procedures. Many EP studies and procedures have implemented ICE because it has several advantages over fluoroscopy and transesophageal echocardiography (TEE). ICE-guided EP procedures can be performed under conscious sedation; esophageal intubation and additional anesthesiologists are not required. Atrial fibrillation (AF) and supraventricular tachycardias (SVT) are the most common tachyarrhythmias in clinical settings. A comprehensive understanding of critical anatomical structures, such as the atrial septum, fossa ovalis (FO), and great heart vessels, is needed for the successful catheter ablation of these arrhythmias.

6.
Rev Cardiovasc Med ; 25(6): 192, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39076324

RESUMEN

Background: The goal of this study was to compare the procedural safety and long-term outcome associated with a combined catheter ablation and left atrial appendage occlusion (LAAO) procedure utilizing intracardiac echocardiography (ICE) guidance versus transesophageal echocardiography (TEE) guidance. The study focuses on implementing LAmbre and Watchman devices in patients diagnosed with nonvalvular atrial fibrillation (AF). Methods: A total of 363 patients diagnosed with nonvalvular AF and who underwent a combined procedure were prospectively enrolled between November 2017 and May 2022. Following 1:1 propensity score matching, the TEE group (n = 132) and ICE group (n = 132) were systematically compared in terms of the combined procedure, imaging parameters, events related to the procedure, and subsequent outcomes during follow-up, including mortality, stroke, bleeding, device-related thrombus (DRT), and peri-device leaks (PDLs). Results: The ICE group exhibited a significant reduction in total procedural duration (153.71 ± 31.71 vs. 174.74 ± 18.79 min), fluoroscopy radiation dosage (207.24 ± 108.39 vs. 268.61 ± 122.88 mGy), left atrial appendage occlusion procedure time (34.69 ± 10.91 vs. 51.46 ± 15.84 min), and contrast agent exposure (108.71 ± 37.59 vs. 158.41 ± 45.00 mL) compared to the TEE group. Angiography and ICE demonstrated a substantial correlation between the left atrial appendage (LAA) orifice and landing zone/LAA ostium (Pearson's correlation coefficient r = 0.808 and 0.536/0.697, two-tailed p < 0.001). No occurrences of device-related embolism, thromboembolism, significant bleeding, or unexpected fatalities were observed in either group. Comparable rates of all-cause death (0.76% vs. 0.76%), stroke or transient ischemic attack (2.27% vs. 1.52%), severe bleeding (1.52% vs. 0.76%), PDL (23.81% vs. 24.62%), and DRT (1.52% vs. 1.52%) were noted after an average follow-up of 18.46 ± 7.70 months in both groups, with no discernible differences. Multivariate logistic regression analysis identified a correlation between LAA velocity and the risk of PDL. Conclusions: The effectiveness and safety of ICE-guided combined treatment were demonstrated to be comparable to TEE guidance, accompanied by the additional advantages of decreased procedure time and fluoroscopy radiation exposure. Clinical Trial Registration: NCT04391504, https://register.clinicaltrials.gov.

7.
Rev Cardiovasc Med ; 25(2): 38, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39077341

RESUMEN

Background: Percutaneous radiofrequency catheter ablation (RFA) in hypertrophic obstructive cardiomyopathy (HOCM) with intracardiac echocardiography (ICE) guidance is a novel method that has been proven to be safe and effective in a small sample size study. RFA of the interventricular septum through a trans-atrial septal approach in HOCM patients with a longer follow-up has not been reported. Methods: 62 consecutive patients from March 2019 to February 2022 were included in this study. The area between the hypertrophied septum and anterior mitral valve (MV) leaflet was established using the three-dimensional system (CARTO 3 system), and all patients received atrial septal puncture under the guidance of intracardiac echocardiography (ICE). Point-by-point ablation was performed to cover the contact area. After ablation, the patients were followed up for 1, 3, 6, and 12 months. Transthoracic echocardiography was performed at 1, 3, 6, and 12 months, and resting and exercise-provoked left ventricular outflow tract (LVOT) gradients were obtained. Results: During the 1-year follow-up, most patients' symptoms improved. The NYHA grading of the patient decreased from 2 (2, 3) at baseline to 2 (1, 2) (p < 0.001). LVOT peak gradient at rest was decreased from 59 ( ± 27) mmHg to 30 ( ± 24) mmHg (p < 0.001), and the provoked peak gradient was decreased from 99 ( ± 33) mmHg to 59 ( ± 34) mmHg (p < 0.001). The average maximum septal thickness was reduced from 21 ( ± 4) mm to 19 ( ± 4) mm (p < 0.001). Conclusions: After a 1-year follow-up, ice-guided radiofrequency ablation for HOCM might be a safe, accurate, and effective method. The catheter might be reliably attached to the ablation target area via trans-atrial septal access.

8.
BMC Cardiovasc Disord ; 24(1): 386, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39061011

RESUMEN

BACKGROUND: The increasing use of intracardiac echocardiography (ICE) in the ablation of premature ventricular complexes (PVCs) has raised questions about its true efficacy and safety. METHODS: This retrospective study collected the periprocedural complications and PVC burden post ablation. The risk factors of PVC recurrence was further explored. RESULTS: The study included patients treated without ICE (control group, n = 451) and with ICE (ICE group, n = 155) from May 2019 to July 2022. The ICE group demonstrated significantly lower fluoroscopy times and X-ray doses. There were no major complications in the ICE group, and the difference in the occurrence of periprocedural complications between the groups was not statistically significant (p = 0.072). The long-term success rates were similar for the control and ICE groups (89.6% and 87.1%, respectively). The origin of PVCs was identified as the independent factor for ablation success. CONCLUSIONS: The use of ICE did not confer an advantage with regard to long-term success in PVCs ablation. To thoroughly evaluate the safety and effectiveness of ICE in PVCs ablation, a prospective, multicenter, randomized study is warranted.


Asunto(s)
Ablación por Catéter , Ecocardiografía , Recurrencia , Complejos Prematuros Ventriculares , Humanos , Ablación por Catéter/efectos adversos , Masculino , Estudios Retrospectivos , Femenino , Resultado del Tratamiento , Complejos Prematuros Ventriculares/cirugía , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/diagnóstico por imagen , Persona de Mediana Edad , Factores de Tiempo , Adulto , Factores de Riesgo , Valor Predictivo de las Pruebas , Potenciales de Acción , Anciano , Frecuencia Cardíaca , Medición de Riesgo
9.
Curr Cardiol Rep ; 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38995505

RESUMEN

PURPOSE OF THE REVIEW: Intracardiac echocardiography (ICE) provides real-time, fluoroless imaging of cardiac structures, allowing optimal catheter positioning and energy delivery during ablation procedures. This review summarizes the use of ICE in catheter ablation of atrial fibrillation (AF). RECENT FINDINGS: Growing evidence suggests that the use of ICE improves procedural safety and facilitates radiofrequency and cryoballoon AF ablation. ICE-guided catheter ablation is associated with reduced procedural duration and fluoroscopy use. Recent studies have examined the role of ICE in guiding novel ablation techniques, such as pulsed field ablation. Finally, the use of ICE allows for early detection and timely management of potentially serious procedural complications. Intracardiac echocardiography offers significant advantages during AF ablation procedures and its use should be encouraged to improve procedural safety and efficacy.

10.
Front Cardiovasc Med ; 11: 1408543, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38993520

RESUMEN

Aim: Periprocedural and postinterventional care of patients undergoing closure of patent foramen ovale (PFO) varies significantly across care providers. Same-day discharge (SDD) after transcatheter interventions is an evolving concept. This study aimed to assess the same-day discharge rate and incidence of complications in patients undergoing PFO closure with intracardiac echocardiography (ICE) using the Gore®Cardioform Septal Occluder (GSO) device. The secondary aim was to analyse the efficacy of femoral vein closure with Perclose ProGlide. Methods: Patients who underwent PFO closure with the GSO device at a university hospital in Stockholm, Sweden, were retrospectively included between March 1, 2017, and June 30, 2020, all with cryptogenic stroke as the indication for the procedure. All patients underwent PFO closure with conscious sedation and local anaesthesia. The indication for all patients was a cryptogenic stroke. Periprocedural imaging was performed using ICE and fluoroscopy in all patients. Patient characteristics and periprocedural data were collected from patient charts. Patients were kept on bed rest for 4-6 h post-intervention. Transthoracic echocardiography and clinical examination, including groin status, were performed before discharge. No clinical routine follow-up was performed the day following the intervention. Clinical follow-up was done by phone call two weeks after the procedure, and echocardiographic follow-up was done after 12 months. Data were analysed using linear and logistic regression models. Results: In total, 262 patients were included, of which 246 (94%) had SDD. 166 patients (63%) received the ProGlide™ system for femoral vein access closure. Post-procedural arrhythmias occurred in 17 (6%) patients, and vascular complications in 9 patients (3%). The overall closure rate at follow-up was 98.5%. 25 out of 264 patients (9.5%) had to be readmitted within the first eight weeks after PFO closure, 16 due to atrial fibrillation warranting electric cardioversion, one due to an arteriovenous fistula that was operated, four due to chest pain/pain at the access site, and four patients developed fever. There was no difference in SDD among patients who received ProGlide™ vs. patients who did not receive ProGlide™. Conclusion: SDD appears safe after transcatheter PFO closure with the GSO device with high procedural success rates. Low rates of complications and readmissions make the intervention suitable for this patient-friendly and cost-effective concept.

11.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

12.
Catheter Cardiovasc Interv ; 104(2): 416-418, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38984646

RESUMEN

A patient presenting with acute ischemic stroke associated with patent foramen ovale (PFO) had concurrent deep vein thrombosis, pulmonary embolism, and new-onset atrial fibrillation. Upon initiation of anticoagulation therapy, the patient developed hemorrhagic transformation of the stroke. The patient's multiple potential sources of embolic stroke were treated with concomitant left atrial appendage occlusion and PFO closure through the PFO, made possible by using the Steerable Amulet Sheath under 3D-intracardiac echocardiography guidance.


Asunto(s)
Apéndice Atrial , Cateterismo Cardíaco , Ecocardiografía Tridimensional , Foramen Oval Permeable , Humanos , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/terapia , Foramen Oval Permeable/complicaciones , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Accidente Cerebrovascular Isquémico/etiología , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Ultrasonografía Intervencional , Masculino , Dispositivo Oclusor Septal , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Anciano , Accidente Cerebrovascular Embólico/etiología , Accidente Cerebrovascular Embólico/prevención & control , Accidente Cerebrovascular Embólico/diagnóstico por imagen , Femenino , Ecocardiografía Transesofágica , Persona de Mediana Edad
14.
Semin Cardiothorac Vasc Anesth ; : 10892532241267351, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39038455

RESUMEN

Background. Intracardiac echocardiography (ICE) is routinely used in cardiac electrophysiology and catheterization labs. It plays a vital role in understanding cardiac anatomy, procedural planning, and early identification of complications. In this review, we describe the utility of ICE for procedures in the electrophysiology lab, including atrial fibrillation ablation, left atrial appendage occlusion device implantation, and cardiac implantable electronic device (CIED) extraction. Intracardiac echocardiography also helps in the identification of complications such as pericardial effusion, pulmonary vein stenosis, and left atrial appendage thrombus. Compared with traditional echocardiographic modalities such as transesophageal echocardiogram (TEE), ICE has equivalent image quality, requires less sedation, and possesses no risk of esophageal injury. The disadvantages of ICE include a learning curve and necessity for central vascular access.

16.
J Cardiothorac Surg ; 19(1): 355, 2024 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-38909226

RESUMEN

BACKGROUND: Cor triatriatum sinister (CTS) is an uncommon congenital cardiac anomaly. Atrial fibrillation (AF) is commonly the initial symptom in patients with CTS, occurring in approximately 32% of the cases. The complexity of performing AF catheter ablation, particularly in cases with persistent AF, increases in patients with CTS due to its unique structural challenges. CASE PRESENTATION: We report the treatment course of a 60-year-old male patient diagnosed with CTS, who underwent catheter ablation of drug-refractory, persistent AF. The complex anatomical structure of the condition made catheter ablation of AF challenging. To navigate these challenges, we performed comprehensive assessments using transthoracic echocardiography and transesophageal echocardiography, along with cardiac computed tomography angiography, prior to treatment initiation. The intricate anatomy of CTS was further clarified during the procedure via intracardiac echocardiography (ICE). Additionally, the complexity of catheter manipulation was further reduced with the aid of the VIZIGO sheath and the vein of Marshall ethanol infusion to achieve effective mitral isthmus blockage, thereby circumventing the impact of the CTS membrane. CONCLUSIONS: This case underscores the complexity and potential of advanced ablation techniques in managing cardiac arrhythmias associated with unusual cardiac anatomies. During the procedure, ICE facilitated detailed modeling of the left atrium, including the membranous structure and its openings, thus providing a clearer understanding of CTS. It is noteworthy that the membrane within the CTS may serve as a potential substrate for arrhythmias, which warrants further validation through larger sample studies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Corazón Triatrial , Humanos , Corazón Triatrial/cirugía , Corazón Triatrial/complicaciones , Corazón Triatrial/diagnóstico por imagen , Masculino , Fibrilación Atrial/cirugía , Persona de Mediana Edad , Ablación por Catéter/métodos , Ecocardiografía Transesofágica/métodos , Ecocardiografía
17.
Sci Rep ; 14(1): 11937, 2024 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-38789491

RESUMEN

Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Transesofágica , Humanos , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Masculino , Femenino , Anciano , Estudios Retrospectivos , Ecocardiografía Transesofágica/métodos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Anciano de 80 o más Años , Ecocardiografía Tridimensional/métodos , Persona de Mediana Edad , Ecocardiografía/métodos , Resultado del Tratamiento , Catéteres Cardíacos , Cierre del Apéndice Auricular Izquierdo
18.
Front Cardiovasc Med ; 11: 1392264, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38737710

RESUMEN

We present a case of a 32-year-old male with a history of palpitations and preexcitation on ECG who underwent altogether four failed catheter ablations using different approaches in the two other electrophysiology centers within two years. ECG showed overt preexcitation with a positive delta wave in lead I and negative in leads V1-V3, suggesting a right free wall accessory pathway. During the electrophysiological study, the accessory pathway was localized on the free lateral wall. However, the electrograms and mapping during atrial and ventricular pacing suggested the presence of true epicardial accessory pathway. Repeated radiofrequency energy delivery with the support of the steerable sheath and excellent contact (as assessed by intracardiac echocardiography) at the earliest ventricular activation was not successful. Therefore, the Farawave catheter (Boston Scientific, Inc) was used, and a flower configuration with the intention to cover the entire atrial attachment of the pathway during ventricular pacing was selected. Application of pulsed field resulted in interruption of accessory pathway conduction. An electrophysiological study one year later confirmed the persistent effect of ablation. This case illustrates the potential utility of pulsed field energy for the ablation of atrial insertion of the accessory pathway with an epicardial course. Such an approach can avoid epicardial mapping and access and may improve the safety of the procedure.

19.
Clin Case Rep ; 12(5): e8906, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38751959

RESUMEN

Key Clinical Message: Atrial fibrillation ablation, including pulmonary vein isolation immediately after left atrial appendage closure (LAAC), is a rare and challenging issue. Intracardiac echocardiography guidance can help identify the LAAC device position for safe atrial fibrillation ablation without LAAC device-related adverse events even immediately after LAAC device implantation. Abstract: Early phase atrial fibrillation (AF) ablation after left atrial appendage closure (LAAC) is a rare and challenging issue. Here, we present a case illustrating the feasibility of AF ablation under intracardiac echocardiography guidance immediately after LAAC device implantation without LAAC device-related adverse events.

20.
J Invasive Cardiol ; 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38718283

RESUMEN

A 79-year-old man with a failed 25-mm CE Magna Ease 3300 surgical prosthesis (Edwards Lifesciences) and of high re-operative surgical risk (STS 8%) presented with dyspnea, NYHA III. Cardiac computed tomography angiography revealed anatomy that was high risk for coronary occlusion with a short right coronary artery height of 6 mm and a valve-to-coronary distance of 2 mm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA