Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Virol Methods ; 300: 114354, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34774617

RESUMEN

BACKGROUND: The cross-contamination of cell lines in culture is a persistent problem. Genetically modified L20B (Mouse) and RD (Human Rhabdomyosarcoma) cell lines are commonly used in poliovirus research, surveillance, and diagnostics. Cross-contamination between these cell lines leads to unreproducible results and unreliable surveillance data, negatively affecting public health. The gold standard method for cell authentication is Short Tandem Repeats analysis, which is time-consuming and expensive. The disadvantage of STR is limited detection of interspecies contamination. METHODS: This assay targets the mitochondrial cytochrome c oxidase subunit I (MTCO1) gene, a highly conserved and emergent DNA barcode region for detection of cross-contamination in RD and L20B cell lines. The MagNA Pure Compact instrument and ABI 7500 Fast Dx Real-time PCR systems were used for DNA extraction and to perform real-time PCR respectively. RESULTS: The newly developed assay is very sensitive with a limit of detection of 100 RD cells/1 million L20B/mL. The amplification efficiency and R2-value were 102.26% and 0.9969 respectively. We evaluated specificity of the assay with five human and four mouse cell lines, as well as monkey and rat cell lines. The assay showed no cross-reactivity with genomic DNA from human, mouse, rat, or monkey cell lines. The analytical sensitivity was also evaluated by spiking varying amounts of RD cells (0.001% - 10%) into L20B cells. There was no difference in CT values when running single-plex or duplex PCR reactions with similar experimental conditions. CONCLUSIONS: We have developed and validated a TaqMan real-time PCR assay, a sensitive method for the detection of cross-contamination of RD and L20B cell lines.


Asunto(s)
Poliovirus , Animales , Línea Celular , Haplorrinos/genética , Humanos , Ratones , Técnicas de Amplificación de Ácido Nucleico , Poliovirus/genética , Ratas , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad
2.
Microscopy (Oxf) ; 62(4): 485-6, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23325931

RESUMEN

L20B cells are a cell line commonly used for the isolation of poliovirus. The current study indicates that L20B cells are chronically infected with a retrovirus-like particle that replicates in the cytoplasm and buds through the plasma membrane. The findings indicate that care is needed in the use of L20B cells for certain virus isolation studies and emphasize the importance of electron microscope studies as an adjunct to the development of diagnostic virology protocols.


Asunto(s)
Microscopía Electrónica/métodos , Retroelementos , Retroviridae/aislamiento & purificación , Liberación del Virus , Animales , Línea Celular , Ratones , Infecciones por Retroviridae
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA