Artículo en Inglés | MEDLINE | ID: mdl-38568230

RESUMEN

PURPOSE: The study aims to investigate the influence of patient- and fracture-specific factors on the occurrence of complications after osteosynthesis of patella fractures and to compare knee joint function, activity, and subjective pain levels after a regular postoperative course and after complications in the medium term. METHODS: This retrospective, multicenter cohort study examined patients who received surgery for patella fracture at level 1 trauma centers between 2013 and 2018. Patient demographics and fracture-specific variables were evaluated. Final follow-up assessments included patient-reported pain scores (NRS), subjective activity and knee function scores (Tegner Activity Scale, Lysholm score, IKDC score), complications, and revisions. RESULTS: A total of 243 patients with a mean follow-up of 63.4 ± 21.3 months were included. Among them, 66.9% of patients underwent tension band wiring (TBW), 19.0% received locking plate osteosynthesis (LPO), and 14.1% underwent screw osteosynthesis (SO). A total of 38 patients (15.6%) experienced complications (TBW: 16.7%; LPO: 15.2%; SO: 11.8%). Implant-related complications of atraumatic fragment dislocation and material insufficiency/dislocation, accounted for 50% of all complications, were significantly more common after TBW than LPO (p = 0.015). No patient-specific factor was identified as a general cause for increased complications. Overall, particularly following complications such as limited range of motion or traumatic refracture, functional knee scores were significantly lower and pain levels were significantly higher at the final follow-up when a complication occurred. Implant-related complications, however, achieved functional scores comparable to a regular postoperative course without complications after revision surgery. CONCLUSION: The present study demonstrated that implant-related complications occurred significantly more often after TBW compared to LPO. The complication rates were similar in all groups.

2.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-770705

RESUMEN

BACKGROUND: The purpose of our study was to evaluate the functional and radiologic outcomes of additive augmentation sutures through rotator cuff for proximal humeral fractures stabilized locking plate in elderly patients. METHODS: We enrolled 74 patients over the age of 60 years who received internal fixation using locking plates for proximal humeral fractures. Of these, 50 patients had additive augmentation sutures through rotator cuff. The mean age at the time of surgery was 72.1 years (range, 60-89 years), and the mean follow-up period was 17.5 months (range, 12-62 months). The humeral neck-shaft angle and humeral head height were used as radiological markers to assess the effect of additive augmentation sutures through rotator cuff. We allocated the patients who received additive augmentation sutures into group A and those who did not into group B. RESULTS: At the final follow-up, the mean Korean Showlder Society score and Constant scores were 88.96 +/- 12.1 and 86.6 +/- 11.9, respectively, in group A and 86.21 +/- 11.8 and 85.3 +/- 11.7, respectively, in group B (p=0.368, 0.271). At the final follow-up, the mean loss in humeral neck-shaft angle from the time of immediate postoperative measurement was 1.6degrees in group A and 4.8degrees in group B, whereas the mean loss in humeral head height was 0.82 mm in group A and 0.52 mm in group B (p=0.029, 0.178). CONCLUSIONS: The surgical outcomes of internal fixation using locking plates for proximal humeral fractures were clinically and radiologically good in elderly patients over the age of 60 years without any observable complications. Further, the loss of humeral head shaft angle at the final follow-up from its initial postoperative measurement was significantly smaller in patients who received an additive augmentation suture than in those who did not. Thus, we conclude that augmentation sutures are a beneficial option for elderly patients that clinicians can consider at the time of surgical decision making.


Asunto(s)
Anciano , Humanos , Toma de Decisiones , Estudios de Seguimiento , Cabeza Humeral , Manguito de los Rotadores , Fracturas del Hombro , Suturas
3.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-76319

RESUMEN

BACKGROUND: The purpose of our study was to evaluate the functional and radiologic outcomes of additive augmentation sutures through rotator cuff for proximal humeral fractures stabilized locking plate in elderly patients. METHODS: We enrolled 74 patients over the age of 60 years who received internal fixation using locking plates for proximal humeral fractures. Of these, 50 patients had additive augmentation sutures through rotator cuff. The mean age at the time of surgery was 72.1 years (range, 60-89 years), and the mean follow-up period was 17.5 months (range, 12-62 months). The humeral neck-shaft angle and humeral head height were used as radiological markers to assess the effect of additive augmentation sutures through rotator cuff. We allocated the patients who received additive augmentation sutures into group A and those who did not into group B. RESULTS: At the final follow-up, the mean Korean Showlder Society score and Constant scores were 88.96 +/- 12.1 and 86.6 +/- 11.9, respectively, in group A and 86.21 +/- 11.8 and 85.3 +/- 11.7, respectively, in group B (p=0.368, 0.271). At the final follow-up, the mean loss in humeral neck-shaft angle from the time of immediate postoperative measurement was 1.6degrees in group A and 4.8degrees in group B, whereas the mean loss in humeral head height was 0.82 mm in group A and 0.52 mm in group B (p=0.029, 0.178). CONCLUSIONS: The surgical outcomes of internal fixation using locking plates for proximal humeral fractures were clinically and radiologically good in elderly patients over the age of 60 years without any observable complications. Further, the loss of humeral head shaft angle at the final follow-up from its initial postoperative measurement was significantly smaller in patients who received an additive augmentation suture than in those who did not. Thus, we conclude that augmentation sutures are a beneficial option for elderly patients that clinicians can consider at the time of surgical decision making.