Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.572
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39005179

RESUMEN

Background: A high incidence of ulnar nerve-related complications has been reported in open reduction and internal fixation for distal humerus fractures (DHFs). To minimise ulnar nerve damage, we used a percutaneous medial screw combined with a posterolateral plate in the elderly. The aim of this study was to evaluate the postoperative complications and functional outcomes of this method. Methods: Data from patients aged over 65 who underwent this surgical procedure for DHFs at a single Level I trauma centre from 2013 to 2021 were extracted. Postoperative complications, reoperations, mean range of motion, Mayo Elbow Performance Index (MEPI) scores and Hand20 scores were retrospectively evaluated. All patients in this study received postoperative rehabilitation by hand therapists at our hospital. Results: We identified 28 patients treated with this method. The mean follow-up period was 8.6 ± 3.7 months. The median intraoperative time was 125 minutes (interquartile range: 105-157 minutes). None of the patients developed ulnar nerve neuropathy, but one patient (3.7%) experienced radial nerve dysfunction. Two patients (7.4%) had nonunion. Implant failure occurred in three patients (11.1%) due to migration of the medial screw. One patient (3.7%) amongst them underwent reoperation. The mean flexion to extension arc was 97 ± 18°, 116 ± 19°, and 116 ± 19° at 1-, 3- and 6-month follow-ups, respectively. According to the MEPI, 20 patients achieved excellent results, seven patients achieved good results and one patient achieved a fair result at the last follow-up. The median Hand20 score was 4.3 (interquartile range: 2.1-14.0) at the 6-month follow-up. Conclusions: The posterolateral plate and medial screw method showed good functional outcomes and few nerve-related complications. This modified method might be a better option for DHFs in elderly patients. Level of Evidence: Level IV (Therapeutic).

2.
J Clin Med ; 13(13)2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38999511

RESUMEN

Objectives: Patients with ankle fractures associated with diabetes experience more complications following standard open reduction-internal fixation (ORIF) than those without diabetes. Augmented fixation strategies, namely extended ORIF and hindfoot nails (HFNs), may offer better results and early weightbearing in this group. The aim of this study was to define the population of patients with diabetes undergoing primary fixation for ankle fractures. Secondarily, we aimed to assess the utilisation of standard and augmented strategies and the effect of these choices on surgical outcomes, including early post-operative weightbearing and surgical complications. Methods: A national multicentre retrospective cohort study was conducted between January and June 2019 in 56 centres (10 major trauma centres and 46 trauma units) in the United Kingdom; 1360 patients with specifically defined complex ankle fractures were enrolled. The patients' demographics, fixation choices and surgical and functional outcomes were recorded. Statistical analysis was performed to compare high-risk patients with and without diabetes. Results: There were 316 patients in the diabetes cohort with a mean age of 63.9 yrs (vs. 49.3 yrs. in the non-diabetes cohort), and a greater frailty score > 4 (24% vs. 14% (non-diabetes cohort) (p < 0.03)); 7.5% had documented neuropathy. In the diabetes cohort, 79.7% underwent standard ORIF, 7.1% extended ORIF and 10.2% an HFN, compared to 87.7%, 3.0% and 10.3% in the non-diabetes cohort. Surgical wound complications after standard-ORIF were higher in the diabetes cohort (15.1% vs. 8.7%) (p < 0.02), but patients with diabetes who underwent augmented techniques showed little difference in surgical outcomes/complications compared to non-diabetes patients, even though early-weightbearing rates were greater than for standard-ORIF. Conclusions: Ankle fractures in diabetes occur in older, frailer patients, whilst lower-than-expected neuropathy rates suggest a need for improved assessment. Augmented surgical techniques may allow earlier weightbearing without increasing complications, in keeping with modern guidelines in ankle fracture management.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38960137

RESUMEN

OBJECTIVES: To investigate the usefulness of the routinely planned six-week outpatient visit and x-ray in patients treated surgically for the most common upper extremity fractures including clavicle, proximal humerus, humeral shaft, olecranon, radial shaft and distal radius. METHOD: This was a retrospective cohort study of all patients treated surgically for the most common upper extremity fractures between 2019 and 2022 in a level 1 trauma center. The first outcome of interest was the incidence of abnormalities found on the x-ray made at the 6-week outpatient visit. Abnormalities were defined as all differences between the intra-operative (or direct postoperative) and 6-week x-ray. In case an abnormality was detected, the hospital records were screened to determine its clinical consequence. The clinical consequences were categorized into requiring either additional diagnostics, additional interventions, change of standard postoperative immobilization, weightbearing or allowed range of motion (ROM). The second outcome of interest was the incidence of deviations from the local standard post operative treatment and follow-up protocol based on the 6-week outpatient visit as a whole. Deviations were also categorized into either requiring additional diagnostics, additional interventions, change of standard postoperative immobilization, weightbearing or allowed range of motion. RESULTS: A total of 267 patients were included. Abnormalities on x-ray at 6 weeks postoperatively were found in only 10 (3.7%) patients of which only 4 (1.5%) had clinical implications (in three patients extra imaging was required and in one patient it was necessary to deviate from standard weightbearing/ROM limitation regime). The clinical/radiological findings during the 6-week outpatient visit led to a deviation from standard in only 8 (3.0%) patients. Notably, the majority of these patients experienced symptoms suggestive for complications. CONCLUSION: The routine 6-week outpatient visit and x-ray, after surgery for common upper extremity fractures, rarely has clinical consequences. It should be questioned whether these routine visits are necessary and whether a more selective approach should be considered. LEVEL OF EVIDENCE: Level IV; Case Series; Prognosis Study.

4.
J Orthop Traumatol ; 25(1): 32, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926180

RESUMEN

BACKGROUND: Lumbar-iliac fixation (LIF) is a common treatment for Tile C1.3 pelvic fractures, but different techniques, including L4-L5/L5 unilateral LIF (L4-L5/L5 ULIF), bilateral LIF (BLIF), and L4-L5/L5 triangular osteosynthesis (L4-L5/L5 TOS), still lack biomechanical evaluation. The sacral slope (SS) is key to the vertical shear of the sacrum but has not been investigated for its biomechanical role in lumbar-iliac fixation. The aim of this study is to evaluate the biomechanical effects of different LIF and SS on Tile C1.3 pelvic fracture under two-legged standing load in human cadavers. METHODS: Eight male fresh-frozen human lumbar-pelvic specimens were used in this study. Compressive force of 500 N was applied to the L4 vertebrae in the two-legged standing position of the pelvis. The Tile C1.3 pelvic fracture was prepared, and the posterior pelvic ring was fixed with L5 ULIF, L4-L5 ULIF, L5 TOS, L4-L5 TOS, and L4-L5 BLIF, respectively. Displacement and rotation of the anterior S1 foramen at 30° and 40° sacral slope (SS) were analyzed. RESULTS: The displacement of L4-L5/L5 TOS in the left-right and vertical direction, total displacement, and rotation in lateral bending decreased significantly, which is more pronounced at 40° SS. The difference in stability between L4-L5 and L5 ULIF was not significant. BLIF significantly limited left-right displacement. The ULIF vertical displacement at 40° SS was significantly higher than that at 30° SS. CONCLUSIONS: This study developed an in vitro two-legged standing pelvic model and demonstrated that TOS enhanced pelvic stability in the coronal plane and cephalad-caudal direction, and BLIF enhanced stability in the left-right direction. L4-L5 ULIF did not further improve the immediate stability, whereas TOS is required to increase the vertical stability at greater SS.


Asunto(s)
Cadáver , Fijación Interna de Fracturas , Fracturas Óseas , Vértebras Lumbares , Huesos Pélvicos , Sacro , Humanos , Masculino , Huesos Pélvicos/lesiones , Fenómenos Biomecánicos , Sacro/lesiones , Sacro/cirugía , Vértebras Lumbares/lesiones , Vértebras Lumbares/cirugía , Vértebras Lumbares/fisiopatología , Fracturas Óseas/cirugía , Fijación Interna de Fracturas/métodos , Ilion , Persona de Mediana Edad , Anciano
5.
Injury ; 55(8): 111692, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38945080

RESUMEN

INTRODUCTION: Humeral shaft fractures are a common injury of the upper limb, with the primary surgical treatment modality being the locking compression plate (LCP) technique. The advent of Anterior medial minimally invasive plate osteosynthesis (MIPO) technology has led to its gradual implementation in clinical practice. However, the efficacy and long-term outcomes of MIPO require further investigation. The objective of this study is to compare the therapeutic effects of LCP and MIPO in the management of humeral shaft fractures. METHODS: The present study conducted a retrospective review of patients diagnosed with humeral shaft fractures between June 2016 and December 2019. The patients were divided into MIPO and LCP groups based on the different surgical methods. The study analyzed the length of hospital stay, radiation exposure, operative time, and postoperative Disabilities of the Arm, Shoulder and Hand (DASH) scores using statistical methods. RESULTS: A total of 53 patients who met the inclusion criteria were included in the study. The MIPO group demonstrated a statistically significant reduction in length of hospital stay compared to the LCP group (length of hospital stay: 5.39 ± 2.23 days vs 12.00 ± 7.19 days, P < 0.001). All patients achieved callus formation after surgery. However, the MIPO group had significantly more radiation exposures than the LCP group (45.96 ± 19.49 vs 5.33 ± 2.20, P < 0.001). Additionally, there was no statistically significant difference observed in the time from admission to surgery, operative time,and healing time between the two groups (the time from admission to surgery: P = 0.593; operative time: P = 0.407; Healing time: P = 0.664). During the postoperative follow-up, the MIPO group exhibited significantly lower 6-week and 3-month DASH scores compared to the LCP group (6-week: 34.17 ± 12.16 vs 45.65 ± 22.94, P = 0.028; 3-month: 17.43 ± 11.70 vs 30.12 ± 9.80, P < 0.001). However, there was no statistically significant difference in the 6-month and 12-month DASH scores between the two groups (6-month: P = 0.787; 12-month: P = 0.058). CONCLUSION: The MIPO technique provides better short-term functional recovery of the shoulder and elbow compared to the LCP technique in the treatment of humeral shaft fractures, while ensuring equivalent surgical healing.

6.
Front Surg ; 11: 1357581, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38919977

RESUMEN

Introduction: Acetabular fractures are among the most challenging injuries in traumatology. The complex anatomy usually requires extensive surgical approaches baring the risk for iatrogenic damage to surrounding neurovascular structures. As a viable alternative, minimally invasive endoscopic techniques have emerged during the recent years. This paper reports on the feasibility of different coupling mechanisms for a novel suprapectineal plate especially designed for minimally invasive acetabular surgery. Methods: A total number of 34 participants contributed to the present study, who differed in their arthroscopic and surgical experience. A laparoscopic model was used to compare four different coupling mechanisms by the number of failed attempts, the time required for plate fixation, the influence of surgical experience as well as the learning success for each individual coupling mechanism. Moreover, the feasibility of each mechanism was evaluated by a questionnaire. Results: The results demonstrate that plates employing grooved and pressure-sliding coupling mechanisms exhibit fewer failed attempts and reduce trial times, especially in contrast to sole sliding mechanisms. Furthermore, our study revealed that proficiency in endoscopic procedures significantly influenced the outcome. Notably, the subjective evaluation of the participants show that the pressure base and pressure-slide base plate designs are the most supportive and feasible designs. Conclusions: In summary, the present study evaluates for the first-time different plate and coupling designs for minimal-invasive surgery, indicating a superior feasibility for plates with a grooved and pressure-sliding mechanism.

7.
J Orthop Case Rep ; 14(6): 186-190, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38910991

RESUMEN

Introduction: The aim of this study was to investigate whether surgery with a 10 mm approach for volar locking plate fixation provides equivalent early post-operative outcomes to conventional incision surgery for distal radius fractures. Materials and Methods: The subjects were divided into a conventional incision group (mean age: 59.1 years, 8 males and 23 females) and a 10 mm approach group (mean age: 59.9 years of age, 6 males and 20 females). The wrist range of motion; grip strength; visual analog scale (VAS); quick disabilities of the arm, shoulder, and hand (Q-DASH) score; and modified Mayo score were assessed at 3 months after surgery. In addition, radial inclination, ulnar variance, and volar tilt were evaluated on post-operative radiography. Results: There was no significant difference between the groups in the wrist range of motion, grip strength, VAS, Q-DASH score, modified Mayo wrist score, and three parameters of post-operative radiography. All patients in both groups had no complications during the perioperative period. Conclusion: We found that a 10 mm approach obtained early post-operative outcomes and alignment comparable to conventional incision surgery for patients with dorsal displaced distal radius fractures.

8.
EFORT Open Rev ; 9(6): 567-580, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38828969

RESUMEN

Purpose: Distal radius fractures (DRFs) represent up to 18% of all fractures in the elderly population, yet studies on the rate of complications following surgery are lacking in the literature. This systematic review aimed to quantify the rate of complications and reinterventions in patients treated with volar plate for distal radius fractures, and analyze if there was any predisposing factor. Methods: A comprehensive literature search was performed on three databases up to January 2023, following PRISMA guidelines. Studies describing volar plate complications and hardware removal were included. A systematic review was performed on complications and rate of reintervention. Assessment of risk of bias and quality of evidence was performed with the 'Down and Black's Checklist for measuring quality'. Results: About112 studies including 17 288 patients were included. The number of complications was 2434 in 2335 patients; the most frequent was carpal tunnel syndrome (CTS), representing 14.3% of all complications. About 104 studies reported the number of reinterventions, being 1880 with a reintervention rate of 8.5%. About 84 studies reported the reason of reintervention; the most common were patient's will (3.0%), pain (1.1%), CTS (1.2%), and device failure (1.1%). Conclusion: The complication rate after DRFs is 13.5%, with the main complication being CTS (14.3%), followed by pain and tendinopathy. The reintervention rate is 8.5%, mainly due to the patient's willingness, and all these patients had plate removal. Correct positioning of the plate and correct information to the patient before surgery can reduce the number of hardware removal, thereby reducing costs and the risk of complications associated with VLP for distal radius fractures.

9.
Cureus ; 16(5): e60479, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38882985

RESUMEN

BACKGROUND: We developed a 3D camera system to track motion in a surgical field. This system has the potential to introduce augmented reality (AR) systems non-invasively, eliminating the need for the invasive AR markers conventionally required. The present study was performed to verify the real-time tracking accuracy of this system, assess the feasibility of integrating this system into the surgical workflow, and establish its potential to enhance the accuracy and efficiency of orthopedic procedures. METHODS: To evaluate the accuracy of AR technology using a 3D camera, a forearm bone model was created. The forearm model was depicted using a 3D camera, and its accuracy was verified in terms of the positional relationship with a 3D bone model created from previously imaged CT data. Images of the surgical field (capturing the actual forearm) were taken and saved in nine poses by rotating the forearm from pronation to supination. The alignment of the reference points was computed at the three points of CT versus the three points of the 3D camera, yielding a 3D rotation matrix representing the positional relationship. In the original system, a stereo vision-based 3D camera, with a depth image resolution of 1280×720 pixels, 30 frames per second, and a lens field of view of 64 specifications, with a baseline of 3 cm, capable of optimally acquiring real-time 3D data at a distance of 40-60 cm from the subject was used. In the modified system, the following modifications were made to improve tracking performance: (1) color filter processing was changed from HSV to RGB, (2) positional detection accuracy was modified with supporting marker sizes of 8 mm in diameter, and (3) the detection of marker positions was stabilized by calculating the marker position for each frame. Tracking accuracy was examined with the original system and modified system for the following parameters: differences in the rotation matrix, maximum and minimum inter-reference point errors between CT-based and camera-based 3D data, and the average error for the three reference points. RESULTS: In the original system, the average difference in rotation matrices was 5.51±2.68 mm. Average minimum and maximum errors were 1.10±0.61 and 15.53±12.51 mm, respectively. The average error of reference points was 6.26±4.49 mm. In the modified system, the average difference in rotation matrices was 4.22±1.73 mm. Average minimum and maximum errors were 0.79±0.49 and 1.94±0.87 mm, respectively. The average error of reference points was 1.41±0.58 mm. In the original system, once tracking failed, it was difficult to recover tracking accuracy. This resulted in a large maximum error in supination positions. These issues were resolved by the modified system. Significant improvements were achieved in maximum errors and average errors using the modified system (P<0.05). CONCLUSION: AR technology using a 3D camera was developed. This system allows direct comparisons of 3D data from preoperative CT scans with 3D data acquired from the surgical field using a 3D camera. This method has the advantage of introducing AR into the surgical field without invasive markers.

10.
Stomatologiia (Mosk) ; 103(3): 16-20, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38904554

RESUMEN

PURPOSE: To study the effect of magnetic therapy on the formation of distraction regenerate of the lower jaw in patients with lower micrognathia. MATERIALS AND METHODS: The study comprised 159 patients with inferior micrognathia of congenital and acquired etiology. The patients were divided into 2 groups. The main group consisted of 112 patients who received magnetic therapy: 55 patients with congenital micrognathia and 57 patients with acquired micrognathia. The control group included 47 patients who did not undergo magnetic therapy: 20 patients with congenital micrognathia and 27 patients with acquired micrognathia. Magnetic therapy was performed daily starting from day 1 or 2 after surgery. Ultrasound monitoring began on the 7th day of distraction and was carried out every 3-4 days, which made it possible to assess the dynamics of the formation of the distraction regenerate. RESULTS: Ultrasound examination on the 7th day of distraction revealed that in the main group the number of distraction regenerates of the normotrophic type was 36.5%, hypotrophic type 18%, hypertrophic type 54.5%. In the control group, the corresponding rates were 53%, 31% and 22%. CONCLUSION: Magnetic therapy induces osteogenesis and accelerates the maturation of the distraction regenerate. This makes it possible to accelerate the pace of distraction without reducing the quality of the regenerate.


Asunto(s)
Magnetoterapia , Micrognatismo , Osteogénesis por Distracción , Humanos , Osteogénesis por Distracción/métodos , Masculino , Niño , Femenino , Micrognatismo/cirugía , Magnetoterapia/métodos , Preescolar , Mandíbula/cirugía , Resultado del Tratamiento
11.
J Clin Med ; 13(11)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38893045

RESUMEN

Background/Objectives: The use of miniplates for stabilizing bones post orthognathic surgery has surged in popularity due to their efficacy in ensuring stability and hastening recovery. However, controversy exists regarding what should be done with these miniplates after surgery. Some surgeons advocate for their removal, while others suggest leaving them in place. This study sought to assess the frequency, causes, and potential risk factors linked with miniplate removal in orthognathic procedures. Methods: A thorough meta-analysis was conducted by scrutinizing studies from various databases including PubMed, Google Scholar, Embase, and Scopus, focusing on publications spanning from 1989 to 2023. Results: Ten studies meeting the inclusion criteria, encompassing 1603 patients, were chosen for inclusion in the meta-analysis. The male-to-female ratio varied from 0.7:1 to 4:1. Overall, 5595 miniplates were inserted, with 294 (5.3%) being subsequently removed. Primary reasons for miniplate removal included infection (161 cases, 2.9%), exposure of miniplates (34 cases, 0.6%), and palpable plates (23 cases, 0.4%). Other indications comprised pain, patient preference, and temperature sensitivity. Less frequent causes for miniplate removal included sinusitis, secondary surgery, and dental pathology. The mean duration of miniplate removal was 5.5 months, with the majority (56.1%) being removed from the mandible rather than the maxilla. In conclusion, this meta-analysis underscores the importance of miniplate removal when hardware causes complications and physical discomfort. The primary reasons for removing miniplates were infection and plate exposure, with the mandible being the most common removal site. Conclusions: These findings emphasize the need for continued monitoring to assess the fate of miniplates in orthognathic surgery and provide valuable information for future clinical decision-making.

12.
J Biomed Mater Res A ; 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38899796

RESUMEN

Bioabsorbable Mg wire-reinforced poly-lactic acid (PLA) matrix composites are potential candidate for load-bearing orthopedic implants offering tailorable mechanical and degradation properties by stacking sequence, volume fraction and surface modification of Mg wires. In this study, we investigated the cytocompatibility, cell-material interaction, and bone differentiation behavior of MC3T3-E1 pre-osteoblast cells for medical-grade PLA, Mg/PLA, and PEO-Mg/PLA (having PEO surface modification on Mg wires) composites. MTT and live/dead assay showed excellent biocompatibility of both composites while cell-material interaction analysis revealed that cells were able to adhere and proliferate on the surface of composites. Cells on the longitudinal surface of composites showed a high and uniform cell density while those on transversal surfaces initially avoided Mg regions but later migrated back after the formation of the passivation layer. Bone differentiation tests showed that cells in extracts of PLA and composites were able to initiate the differentiation process as osteogenesis-related gene expressions, alkaline phosphatase protein quantity, and calcium mineralization increased after 7 and 14 days of culture. Interestingly, the bone differentiation response of PEO-Mg/PLA composite was found to be similar to medical-grade PLA, proving its superiority over Mg/PLA composite.

13.
Cureus ; 16(4): e58576, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38765412

RESUMEN

Background The advantage of pronator quadratus (PQ) repair following internal fixation via the volar approach in distal radius fracture (DRF) surgery remains unconfirmed in the literature. The aim of this study was to compare grip strength, patient-reported outcomes, and functional results between patients with an intact PQ and those with a ruptured PQ before undergoing surgery with a volar locking plate for dorsally displaced unstable extra-articular DRFs. Methods A total of 120 patients aged 55 years and older were included in a randomized controlled trial comparing a volar locking plate with a dorsal nail plate. Of the 60 patients randomized to the volar plate group, the integrity of the PQ muscle was recorded during surgery for 55 patients, who were included in this study. The outcomes measured were the Quick Disabilities of the Arm, Shoulder, and Hand Outcome Measure (QuickDASH) score, the Patient-Rated Wrist Evaluation (PRWE) score, the EQ-5D index, the visual analog scale (VAS) score, grip strength, and range of motion (ROM). Results The median age was 67 years (range 55 to 88), and the one-year follow-up rate was 98%. Patients with an identified intact PQ (28/55) before surgical release had better QuickDASH scores after one year (2.5 vs 8.0, mean difference 5.5, 95% CI: 1.3 to 9.8, p=0.028). Patients in the intact group also had better EQ-5D Index scores after one year (0.94 vs 0.85, mean difference 0.089, 95% CI: 0.004 to 0.174, p=0.031), and demonstrated better grip strength throughout the trial; after one year: 24 kg vs 20 kg (mean difference 3.9; 95% CI: 0.3 to 7.6, p=0.016). After one year, the intact group had regained 96% of their grip strength and the nonintact group had regained 93% of their grip strength compared to the uninjured side. The observed differences may be of questionable clinical importance, as they were lower than those of previously proposed minimal clinically important differences (MCIDs). Conclusions Patients with a DRF and a ruptured PQ prior to surgery exhibited higher QuickDASH scores and lower EQ-5D index scores after one year. The integrity of the PQ should be reported in future studies.

14.
Arch Orthop Trauma Surg ; 144(6): 2665-2671, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38801533

RESUMEN

INTRODUCTION: Open book injuries are challenging injuries that oftentimes require surgical treatment. Currently, treatment is performed with symphyseal plating requiring extensive surgery and entirely limiting physiological movement of the symphyseal joint, frequently resulting in implant failure. Therefore, we investigated the biomechanical properties of a minimally invasive tape suture construct (modified SpeedBridge™) as an alternative stabilization technique for the treatment of open book injuries in human cadaver pelvic rings. MATERIALS AND METHODS: The symphysis of 9 human cadaver pelvises was dissected and dilated to 3 cm creating an open book injury. Next, the two osteosynthesis methods (plating, modified SpeedBridge™) were applied. All specimens then underwent cyclic horizontal and vertical loading, simulating biomechanical forces while sitting, standing and walking. For statistical analysis, 3D dislocation (mm) was calculated. RESULTS: Total displacement (mm) of the pubic symphysis displayed the following means and standard deviations: native group 1.34 ± 0.62 mm, open book group 3.01 ± 1.26 mm, tape group 1.94 ± 0.59 mm and plate group 1.37 ± 0.41 mm. Comparison between native and open book (p = 0.029), open book and plate (p = 0.004), open book and tape (p = 0.031), as well as tape and plate group (p = 0.002) showed significant differences. No significant differences were found when comparing the native and tape (p = 0.059), as well as the native and plate (p = 0.999) group. CONCLUSION: While both osteosynthesis techniques sufficiently stabilized the injury, symphyseal plating displayed the highest rigidity. The modified SpeedBridge™ as a tape suture construct provided statistically sufficient biomechanical stability while maintaining symphyseal micro mobility, consequently allowing ligamental healing of the injured joint without iatrogenic arthrodesis.


Asunto(s)
Cadáver , Sínfisis Pubiana , Humanos , Sínfisis Pubiana/lesiones , Sínfisis Pubiana/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Masculino , Placas Óseas , Femenino , Fracturas Óseas/cirugía
15.
Schweiz Arch Tierheilkd ; 166(6): 309-320, 2024 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-38807434

RESUMEN

INTRODUCTION: The aim of this retrospective study is to describe and compare conservative and surgical treatment of navicular fractures in horses. An attempt is made to identify critical points that can favorably influence the prognosis of this orthopedic disease. All horses treated for a navicular fracture at the Equine Clinic, Vetsuisse Faculty, University of Zurich between 2005 and 2017 were included in this study. The severity of lameness at initial examination, radiographic assessment, hoof conformation, treatment (conservative or surgical), complications and outcome were determined from the medical records. Conservative and surgical treatment consisted of stable rest, a controlled exercise program and therapeutic orthopedic shoeing. During surgical treatment, fracture reduction was also carried out with a cortical screw. Computer assisted surgery were used in five horses and computer tomography in three horses. Follow-up examinations included clinical and radiographic examinations. The outcome was divided into three categories: 1 = very good; 2 = good; 3 = poor. Twelve horses met the inclusion criteria; Four horses were treated conservatively and eight were treated surgically. After conservative treatment, two horses (50 %) had a very good outcome and two (50 %) had a good outcome. After surgical treatment, four horses (50 %) had a very good outcome and four (50 %) had a poor outcome. Overall, 67 % of horses had a very good or good outcome, although radiographic signs of bone healing was not present in any of these cases. Various complications were identified, such as the fracture of a screw, the fragmentation of the small navicular bone fragment, the development of osteoarthrosis in the coffin joint and progressive podotrochosis. This study shows that the prognosis of navicular fractures is generally cautious and that degenerative changes to the navicular apparatus worsen the prognosis. In the present study, surgical treatment did not improve the prognosis of navicular fractures despite the intrasurgical use of three-dimensional imaging. However, technical advances could reduce the complication rate in the future.


INTRODUCTION: Le but de cette étude rétrospective était de décrire et de comparer le traitement conservateur et chirurgical des fractures de l'os naviculaires chez le cheval. Une tentative est faite pour identifier les points critiques qui peuvent influencer favorablement le pronostic de cette maladie orthopédique. Tous les chevaux traités pour une fracture de l'os naviculaire à la Clinique équine de la Faculté Vetsuisse de l'Université de Zurich entre 2005 et 2017 ont été inclus dans cette étude. La gravité de la boiterie lors de l'examen initial, l'évaluation radiographique, la conformation du sabot, le traitement (conservateur ou chirurgical), les complications et le résultat ont été déterminés à partir des dossiers médicaux. Le traitement conservateur et chirurgical consistait en un repos au box, un programme d'exercice contrôlé et un ferrage orthopédique thérapeutique. Au cours du traitement chirurgical, une réduction de la fracture a également été effectuée à l'aide d'une vis corticale. La chirurgie assistée par ordinateur a été utilisée sur cinq chevaux et la tomographie assistée par ordinateur sur trois chevaux. Les examens de suivi comprenaient des examens cliniques et radiographiques. Les résultats ont été divisés en trois catégories: 1 = très bon; 2 = bon; 3 = mauvais. Douze chevaux répondaient aux critères d'inclusion ; quatre chevaux ont été traités de manière conservatrice et huit ont été traités chirurgicalement. Après un traitement conservateur, deux chevaux (50 %) ont eu un très bon résultat et deux (50 %) un bon résultat. Après le traitement chirurgical, quatre chevaux (50 %) ont eu un très bon résultat et quatre (50 %) un mauvais résultat. Dans l'ensemble, 67 % des chevaux ont eu un très bon ou un bon résultat, bien que les signes radiographiques de guérison osseuse n'aient été présents dans aucun de ces cas. Diverses complications ont été identifiées, telles que la fracture d'une vis, la fragmentation du petit fragment de l'os naviculaire, le développement d'une arthrose dans l'articulation interphalangienne distale et une podotrochlose progressive. Cette étude montre que le pronostic des fractures de l'os naviculaire est généralement réservé et que les modifications dégénératives de l'appareil naviculaire aggravent le pronostic. Dans la présente étude, le traitement chirurgical n'a pas amélioré le pronostic des fractures du naviculaire malgré l'utilisation intra-chirurgicale de l'imagerie tridimensionnelle. Cependant, les progrès techniques pourraient réduire le taux de complications dans le futur.


Asunto(s)
Tratamiento Conservador , Fracturas Óseas , Animales , Caballos/lesiones , Fracturas Óseas/veterinaria , Fracturas Óseas/cirugía , Estudios Retrospectivos , Pronóstico , Tratamiento Conservador/veterinaria , Enfermedades de los Caballos/cirugía , Huesos Tarsianos/lesiones , Huesos Tarsianos/cirugía , Resultado del Tratamiento , Cojera Animal/etiología , Masculino , Femenino
16.
Br J Neurosurg ; : 1-9, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695277

RESUMEN

BACKGROUND: Sacropelvic fractures with multidirectional instability require complex reduction and stabilisation techniques. Triangular osteosynthesis reconstruction is an established technique but hardware failure rates remain high and screw trajectories unfamiliar to spine surgeons. Our technique allows de-rotation of the pelvis, fracture reduction in both vertical and transverse planes, immediate weight bearing and is more reproducible for complex spine surgeons. OBJECTIVE: To describe our case series of dual triangular osteosynthesis reduction and stabilisation for complex sacropelvic fractures. METHODS: Retrospective case series of patients treated for unstable multiplanar sacropelvic fractures, at a level one trauma centre in the United Kingdom. Chart review was conducted to assess clinical features, radiology (plain radiographs, CT and MRI), surgical techniques and clinical and radiological outcomes. RESULTS: A total of six patients with four male and two females were included. Mean age of the cohort was 37.5 years (range 19-61 years) and average length of follow-up was 34.5 months (range 13-75 months). Three patients had neurological injury and three were intact. Four patients had associated thoraco-abdominal or lower limb injuries requiring intervention. All patients underwent surgery with reduction and stabilisation using dual triangular osteosynthesis constructs. At final follow-up, one patient had persistent bladder dysfunction (present preoperatively), one remained ASIA A from concomitant cord injury in the thoracic spine, and one patient with L5 and S1 weakness completely recovered. There were no metalwork complications and all patients achieved radiological fusion. CONCLUSION: Our technique of reduction and stabilisation of complex multidirectional sacropelvic fractures leads to a biomechanically strong construct with immediate stability, and without risk of hardware failure.

17.
JSES Int ; 8(3): 446-450, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38707561

RESUMEN

Background: The number of malignant tumors is increasing as are bone metastases, such as those in the humerus. Arm function is important for an independent everyday life. In this study, compound osteosynthesis of metastatic fractures of the humerus is examined for its suitability in light of the competing risk of death. Methods: This retrospective monocentric study includes a cohort of tumor patients who underwent primary compound osteosynthesis for pathological humeral fractures. The main endpoint was the continued existence of compound osteosynthesis using competing risk analysis to contrast failure and death. Failure was defined as mechanical failure of the osteosynthesis construct like refracture or plate-and-screw dislocation or loosening, which provides an indication for reintervention. Other complications are also described. Results: We included 36 consecutive patients (64% male, mean age: 71.6 yr) from September 2007 to October 2020. In 58% of the cases, the left humerus was fractured. Lung carcinoma was the most common cause of bone metastases (27.8%). Compound osteosynthesis was performed with a median delay of 5 days after diagnosis of the pathologic fracture. Postoperative complications occurred in 7 of the 36 patients (19.4%): radial nerve palsy (n = 3), postoperative hematoma (n = 2), refracture (n = 2), and screw loosening (n = 1). Few mechanical failures (8.3%) occurred within the first year; only 1 patient needed revision of the osteosynthesis (2.8%). Median patient survival after compound osteosynthesis was 26.6 weeks. Competing risk analysis showed that for up to 2 years, the risk of death is clearly dominant over the risk of osteosynthesis failure from surgery. Conclusion: Our study shows that compound osteosynthesis of the humerus is a suitable option for patients with pathologic humerus fractures. Compound osteosynthesis of the humerus usually survives the duration of malignant tumor disease.

18.
Arch Bone Jt Surg ; 12(4): 256-263, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38716182

RESUMEN

Objectives: The surgical management of periprosthetic fractures (PPF) and periimplant fractures (PIF) can be challenging. The locking attachment plate (LAP) was proposed in recent years for the osteosynthesis of such fractures. The aim of this study was to assess the experience of a third-level hospital with LAP for the treatment of PPF and PIF, and analyse the clinical outcomes. Methods: Data were prospectively collected and analysed from all patients whose PPF/PIF was treated surgically with LAP in a third-level hospital from June 2018 to June 2022. All fractures were postoperative low-energy femur fractures. The minimum follow-up period was six months. Results: Thirty-eight patients (31 women) met the eligibility criteria. The mean age was 86.3 years. The median time until surgery was 4 days. A mean of 3.61 screws were used for each LAP. The mean femur plate length was 14 holes, and the mean working length 7.1 holes. The median hospital stay was nine days. The mean follow-up was 19.56 months. At one month, 12 patients tolerated partial weight-bearing. Five patients walked independently indoors. One patient had died and seven patients were readmitted. At six months, six more patients had died. Fifteen patients tolerated full weight-bearing (FWB). Nine patients walked independently indoors, six outdoors. Twenty-five patients reached fracture consolidation without malalignment. Nine patients were readmitted. At 12 months, another patient had died. Seventeen patients tolerated FWB. Eleven patients walked independently indoors, six outdoors. Twenty-five patients achieved fracture consolidation without malalignment. Five patients were readmitted. Fourteen patients crossed the two-year postoperative threshold. All achieved fracture consolidation. Two patients passed the 4-year postoperative milestone. Conclusion: The clinical results of patients whose PPF or PIF was treated with the LAP are promising. This fixation method is a viable option to be considered when planning surgery for such fractures.

19.
J Med Life ; 17(2): 188-194, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38813362

RESUMEN

This study aimed to share our experience of a self-developed plate for acetabular fracture fixation through the presentation of clinical cases. Eight patients with complex acetabular fractures (Letournel classification) underwent surgery using a modified Stoppa approach and the novel plate design between 2021 and 2023 at the National Scientific Center for Traumatology and Orthopedics. Criteria such as the mechanism of injury, type of fracture, surgical approach, intraoperative and postoperative complications, quality of reduction, and functional and radiological results were evaluated. All patients included in the study presented complex types of acetabular fractures according to the Letournel classification. In all cases, surgical interventions were performed using a modified Stoppa approach. The assessment of reduction quality was conducted based on the radiological standards established by Matta. The reduction in quality was excellent in two patients, good in four, and satisfactory in two. One patient developed a post-traumatic false joint requiring additional surgery. The remaining patients achieved fracture healing with satisfactory Harris Hip Score (HHS) scores, indicating good overall function. The results of the self-developed plate for acetabular fracture fixation in our series were satisfactory.


Asunto(s)
Acetábulo , Placas Óseas , Fijación Interna de Fracturas , Fracturas Óseas , Humanos , Acetábulo/cirugía , Acetábulo/lesiones , Masculino , Adulto , Femenino , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen , Fijación Interna de Fracturas/métodos , Persona de Mediana Edad , Adulto Joven
20.
Cureus ; 16(4): e58759, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38779225

RESUMEN

INTRODUCTION:  There are several operative modes to address hand fractures to gain better anatomical and functional results including external fixator, percutaneous K-wire fixation, lag screw fixation, tension band wiring, intra-medullary nails or wires, and plate-screw fixation. We evaluated the results of plate osteosynthesis in fractures of metacarpals and phalanges in a prospective manner. MATERIAL AND METHODS:  A total 50 adults (19-60 years) of either sex having 58 fractures managed by miniature plate osteosynthesis and followed for a minimum six months (6-19), including metacarpal and phalangeal fractures (unstable or serial fractures), intra-articular fractures, fracture-dislocation of proximal interphalangeal and distal interphalangeal joints with joint incongruity or subluxation were enrolled while contaminated compound fractures, pathological fractures and cases of reimplantation were excluded from study. Clinical assessment was done using the American Society for Surgery of the Hand (ASSH), total active flexion (TAF), total active range of motion (TAM) score, and the Disabilities of the Arm, Shoulder, and Hand (quick DASH) score while sequential radiographs were done at each follow-up. RESULT: All the fractures had perfect union clinically as well as radiologically with a mean duration of six weeks while functional outcomes in reference to clinical scores were observed excellent and fair in all cases. None of the cases had any loss of reduction, loosening of the implant, or other major complications. CONCLUSIONS: Miniature plate fixation provides enough stability in metacarpal and phalanges fractures, thereby allowing immediate active movements, which leads to excellent functional outcomes and early return to normal activities.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...