Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 594
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39305349

RESUMEN

ApoE-/- mice are a widely used preclinical model of atherosclerosis, potentially accelerated by a Western diet (WD) or uremia. We aimed to compare hybrid 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography-magnetic resonance (PET-MR) and immunostaining in ApoE-/- models of accelerated atherosclerosis. Five groups were studied: standard diet-fed ApoE-/- (n = 7), standard diet-fed and uremic ApoE-/- (n = 7), WD ApoE-/- (n = 7), WD and uremic ApoE-/- (n = 6), and control C57BL/6J mice (n = 6). Uremia was induced by electrocoagulation of the right kidney at 8 weeks old, followed 2 weeks later by a contralateral nephrectomy. 18F-FDG PET-MR imaging and histological staining (anti-CD4, -CD8, -CD11c, -CD20, -CD31, -CD68, -CD163, -interferon-γ, interleukin-1α, -1ß, -6, -17 A antibodies) were performed in 18-week-old mice, i.e., 8 weeks after 5/6 nephrectomy and/or WD. 18F-FDG uptake was similar in all groups. In contrast, histological staining highlighted higher percentages of CD8-, CD68-, or CD11c-positive cells in ApoE-/- aortic samples than in wild-type aortic samples. In addition, immunostaining revealed some differences between ApoE-/- mouse groups. Only the WD seemed to contribute to these differences. Using immunostaining, WD appeared to be a stronger accelerator of atherosclerosis than uremia. However, 18F-FDG PET-MR imaging failed to demonstrate in vivo increased aortic glucose uptake in these models.

2.
EJNMMI Res ; 14(1): 79, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225971

RESUMEN

BACKGROUND: Neuromelanin is mostly located in dopaminergic neurons in the substantia nigra (SN) pars compacta, and can be detected by magnetic resonance imaging (MRI). It is a promising imaging-base biomarker for neurological diseases. We previously developed a melanin-specific probe N-(2-(diethylamino)-ethyl)-18F-5-fluoropicolinamide (18F-P3BZA), which was initially developed for the imaging of melanoma. 18F-P3BZA exhibited high levels of binding to the melanin in vitro and in vivo with high retention and favorable pharmacokinetics. In this study we further investigated whether 18F-P3BZA could be used to quantitatively detect neuromelanin in the SN in healthy rhesus macaques. RESULTS: 18F-P3BZA exhibited desired hydrophobicity with estimated log Know 5.08 and log D7.4 1.68. 18F-P3BZA readily crossed the blood-brain barrier with brain transport coefficients (Kin) of 40 ± 8 µL g-1s-1. 18F-P3BZA accumulated specifically in neuromelanotic PC12 cells, melanin-rich melanoma cells, and melanoma xenografts. Binding of 18F-P3BZA to B16F10 cells was much higher than to SKOV3 cells at 60 min (6.17 ± 0.53%IA and 0.24 ± 0.05%IA, respectively). In the biodistribution study, 18F-P3BZA had higher accumulation in B16F10 tumors (6.31 ± 0.99%IA/g) than in SKOV3 tumors (0.25 ± 0.09%IA/g). Meanwhile, 18F-P3BZA uptake in B16F10 tumors could be blocked by excess cold 19F-P3BZA (0.81 ± 0.02%IA/g, 88% inhibition, p < 0.05). PET/MRI 18F-P3BZA provided clear visualization of neuromelanin-rich SN at 30-60 min after injection in healthy macaques. The SN to cerebella ratios were 2.7 and 2.4 times higher at 30 and 60 min after injection. In in vitro autoradiography studies 18F-P3BZA exhibited high levels of binding to the SN, and almost no binding to surrounding midbrain tissues. CONCLUSION: 18F-P3BZA PET/MRI clearly images neuromelanin in the SN, and may assist in the early diagnosis of neurological diseases associated with abnormal neuromelanin expression.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39256216

RESUMEN

PURPOSE: For several years, oncological positron emission tomography (PET) has developed beyond 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG). This umbrella review of meta-analyses aims to provide up-to-date, comprehensive, high-level evidence to support appropriate referral for a specific radiopharmaceutical PET/computed tomography (CT) or PET/magnetic resonance (MR) in the diagnosis and staging of solid cancers other than brain malignancies. METHODS: We performed a systematic literature search on the PubMed/MEDLINE and EMBASE databases for meta-analyses assessing the accuracy of PET/CT and/or PET/MRI with [18F]FDG, somatostatin- receptor-targeting 68Ga-DOTA-peptides, 18F-labelled dihydroxyphenylalanine ([18F]DOPA), prostate-specific membrane antigen (PSMA)-targeted radioligands, and fibroblast activation protein inhibitors (FAPI) in the diagnosis/disease characterisation and staging of solid cancers other than brain tumours. RESULTS: The literature search yielded 449 scientific articles. After screening titles and abstracts and applying inclusion and exclusion criteria, we selected 173 meta-analyses to assess the strength of evidence. One article was selected from references. Sixty-four meta-analyses were finally considered. The current evidence corroborates the role of [18F]FDG as the main player in molecular imaging; PSMA tracers are useful in staging and re-staging prostate cancer; somatostatin-targeting peptides (e.g. [68Ga]Ga- DOTA-TOC and -TATE) or [18F]DOPA are valuable in neuroendocrine tumours (NETs). FAPI has emerged in gastric cancer assessment. According to search and selection criteria, no satisfactory meta-analysis was selected for the diagnosis/detection of oesophageal cancer, the diagnosis/detection and N staging of small cell lung cancer and hepatic cell carcinoma, the diagnosis/detection and M staging of melanoma and Merkel cell carcinoma, cervical, vulvar and penis cancers, the N and M staging of lung and gastroenteropancreatic NET, testicular cancer, and chondrosarcoma, and the M staging of differentiated thyroid, bladder and anal cancers. CONCLUSION: The comprehensive high-level evidence synthesised in the present umbrella review serves as a guiding compass for clinicians and imagers, aiding them in navigating the increasingly intricate seascape of PET examinations.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39269656

RESUMEN

PURPOSE: Quantification of PSMA expression via PSMA PET is well-established, however quantification of PSMA via immunohistochemistry (IHC) is not standardized. Our aim was to determine the most optimal PSMA IHC scoring system to quantify PSMA expression with PSMA PET as reference standard. METHODS: Primary intermediate- and high-risk prostate cancer patients received an [18F]PSMA-1007 PET/MRI followed by radical prostatectomy. SUVmax, SUVmean and Ki of the prostate tumor was determined. Prostate tumors were stained with anti-PSMA antibodies and scored by 2 readers via 10 IHC scoring systems: histochemical score (H-score), immunoreactivity scorepredominant intensity (IRSpredominant intensity), IRS classificationpredominant intensity, IRSmean intensity, IRS classificationmean intensity, Allred score, predominant expression pattern, Shannon diversity index (SDI), percentage negatively stained cells and total percentage positively stained cells. Spearman's rank correlation coefficients (ρ) were calculated between PET parameters and IHC scoring systems. Interreader agreement for the IHC scoring systems was measured by the intraclass correlation coefficient (ICC). RESULTS: Fifty tumors in 46 patients were analysed. H-score had the best correlation with SUVmax (ρ 0.615 p < 0.0001) and SUVmean (ρ 0.570, p < 0.0001) and the second best correlation with Ki (ρ 0.411, p = 0.0030). SDI had the best correlation with Ki (ρ -0.440, p = 0.0014) and the second best correlation with SUVmax (ρ -0.516, p = 0.0001) and SUVmean (ρ -0.490, p = 0.0003). A moderate interreader agreement was observed for H-score (ICC 0.663, 95% CI 0.495-0.797) and SDI (ICC 0.546, 95% CI 0.354-0.725). CONCLUSION: H-score had the best correlation with PSMA PET quantification and an acceptable interreader agreement. Therefore, we deem H-score the most optimal PSMA IHC scoring system.

5.
J Appl Clin Med Phys ; : e14507, 2024 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-39231184

RESUMEN

BACKGROUND: In modern positron emission tomography (PET) with multi-modality imaging (e.g., PET/CT and PET/MR), the attenuation correction (AC) is the single largest correction factor for image reconstruction. One way to assess AC methods and other reconstruction parameters is to utilize software-based simulation tools, such as a lesion insertion tool. Extensive validation of these simulation tools is required to ensure results of the study are clinically meaningful. PURPOSE: To evaluate different PET AC methods using a synthetic lesion insertion tool that simulates lesions in a patient cohort that has both PET/MR and PET/CT images. To further demonstrate how lesion insertion tool may be used to extend knowledge of PET reconstruction parameters, including but not limited to AC. METHODS: Lesion quantitation is compared using conventional Dixon-based MR-based AC (MRAC) to that of using CT-based AC (CTAC, a "ground truth"). First, the pre-existing lesions were simulated in a similar environment; a total of 71 lesions were identified in 18 pelvic PET/MR patient images acquired with a time-of-flight simultaneous PET/MR scanner, and matched lesions were inserted contralaterally on the same axial slice. Second, synthetic lesions were inserted into four anatomic target locations in a cohort of four patients who didn't have any observed clinical lesions in the pelvis. RESULTS: The matched lesion insertions resulted in unity between the lesion error ratios (mean SUVs), demonstrating that the inserted lesions successfully simulated the original lesions. In the second study, the inserted lesions had distinct characteristics by target locations and demonstrated negative max-SUV%diff trends for bone-dominant sites across the patient cohort. CONCLUSIONS: The current work demonstrates that the applied lesion insertion tool can simulate uptake in pelvic lesions and their expected SUV values, and that the lesion insertion tool can be extended to evaluate further PET reconstruction corrections and algorithms and their impact on quantitation accuracy and precision.

6.
Brain Commun ; 6(5): fcae222, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39229489

RESUMEN

The structural network damages in amyotrophic lateral sclerosis patients are evident but contradictory due to the high heterogeneity of the disease. We hypothesized that patterns of structural network impairments would be different in amyotrophic lateral sclerosis subtypes by a data-driven method using 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance hybrid imaging. The data of positron emission tomography, structural MRI and diffusion tensor imaging in fifty patients with amyotrophic lateral sclerosis and 23 healthy controls were collected by a 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance hybrid. Two amyotrophic lateral sclerosis subtypes were identified as the optimal cluster based on grey matter volume and standardized uptake value ratio. Network metrics at the global, local and connection levels were compared to explore the impaired patterns of structural networks in the identified subtypes. Compared with healthy controls, the two amyotrophic lateral sclerosis subtypes displayed a pattern of a locally impaired structural network centralized in the sensorimotor network and a pattern of an extensively impaired structural network in the whole brain. When comparing the two amyotrophic lateral sclerosis subgroups by a support vector machine classifier based on the decreases in nodal efficiency of structural network, the individualized network scores were obtained in every amyotrophic lateral sclerosis patient and demonstrated a positive correlation with disease severity. We clustered two amyotrophic lateral sclerosis subtypes by a data-driven method, which encompassed different patterns of structural network impairments. Our results imply that amyotrophic lateral sclerosis may possess the intrinsic damaged pattern of white matter network and thus provide a latent direction for stratification in clinical research.

7.
MAGMA ; 37(4): 749-763, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39167304

RESUMEN

We aim to provide an overview of technical and clinical unmet needs in deep learning (DL) applications for quantitative and qualitative PET in PET/MR, with a focus on attenuation correction, image enhancement, motion correction, kinetic modeling, and simulated data generation. (1) DL-based attenuation correction (DLAC) remains an area of limited exploration for pediatric whole-body PET/MR and lung-specific DLAC due to data shortages and technical limitations. (2) DL-based image enhancement approximating MR-guided regularized reconstruction with a high-resolution MR prior has shown promise in enhancing PET image quality. However, its clinical value has not been thoroughly evaluated across various radiotracers, and applications outside the head may pose challenges due to motion artifacts. (3) Robust training for DL-based motion correction requires pairs of motion-corrupted and motion-corrected PET/MR data. However, these pairs are rare. (4) DL-based approaches can address the limitations of dynamic PET, such as long scan durations that may cause patient discomfort and motion, providing new research opportunities. (5) Monte-Carlo simulations using anthropomorphic digital phantoms can provide extensive datasets to address the shortage of clinical data. This summary of technical/clinical challenges and potential solutions may provide research opportunities for the research community towards the clinical translation of DL solutions.


Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Fantasmas de Imagen , Tomografía de Emisión de Positrones , Humanos , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Método de Montecarlo , Artefactos , Aumento de la Imagen/métodos , Imagen Multimodal/métodos , Simulación por Computador , Imagen de Cuerpo Entero/métodos , Movimiento (Física)
8.
Int J Cardiol ; 414: 132425, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39098608

RESUMEN

PURPOSE: The fibroblast activation protein inhibitor-04 (FAPI-04) specifically binds to the FAP of activated myocardial fibroblasts, which makes 68Ga-labelled FAPI-04 (68Ga-FAPI-04) positron emission tomography (PET)/magnetic resonance (MR) a new potential imaging technique for the evaluation of myocardial fibrosis. This study aimed to evaluate the potential value of 68Ga-FAPI-04 PET/MR in assessing and predicting changes in renal function in patients with acute ST-elevation myocardial infarction (STEMI). METHODS: Thirty-three patients with STEMI were included in this study. 68Ga-FAPI-04 PET/MR and cardiac magnetic resonance were performed before discharge in all patients. Worsening renal function(WRF) was defined as ≥20% decrease in estimated glomerular filtration rate(eGFR) from baseline to 12 months. RESULTS: The WRF group demonstrated higher 68Ga-FAPI-04 uptake volume (UV) at baseline than the non-WRF group(P = 0.009). 68Ga-FAPI-04 UV at baseline was correlated with follow-up eGFR (r = -0.493, P = 0.004). 68Ga-FAPI-04 UV at baseline was a significant predictor of WRF (OR = 1.014, P = 0.029) at 12 months after STEMI. CONCLUSIONS: As an effective tool to non-invasively quantify myocardial fibroblast activation, 68Ga-FAPI-04 PET/MR has potential value for assessing and predicting worsening renal function in patients with STEMI.


Asunto(s)
Radioisótopos de Galio , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Infarto del Miocardio con Elevación del ST , Humanos , Masculino , Femenino , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/fisiopatología , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Anciano , Tasa de Filtración Glomerular/fisiología , Imagen por Resonancia Cinemagnética/métodos , Estudios de Seguimiento , Radiofármacos , Quinolinas
9.
Phys Med Biol ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39214124

RESUMEN

OBJECTIVE: Image quality in positron emission tomography (PET) is influenced by positron range. In this work, the effect of the magnetic field of a PET/MR Siemens Biograph mMR 3T on the quality of PET images was studied. APPROACH: Experimental measurements were conducted using18F and68Ga-filled phantoms to quantify image uniformity, recovery coefficients (RCs), spill-over ratios and percent contrast for spherical lesions. Tissue-equivalent phantoms (lung inhale and exhale, adipose, water, trabecular and cortical bone) were used together with a line source to quantify the impact of the magnetic field on the reconstructed PET images. A comparative analysis was made with images obtained with a PET/CT Biograph Vision 600, using the same radionuclides and phantoms. MAIN RESULTS: Higher RCs values were obtained when the image quality phantom was filled with68Ga and scanned with the PET/MR system compared to those obtained with the PET/CT scanner. Hot spheres in the lesion detectability phantom, appear contracted in the transverse direction in the PET/MR system, an effect more evident for68Ga compared to18F, but no elongation in the direction parallel to the magnetic field was observed. In the PET/CT scanner, radial profiles taken from axial slices of line sources, show longer distribution tails extending beyond 20 mm when filled with68Ga and placed inside lung-inhale tissue. In the PET/MR scanner the radial profiles of all materials collapsed into a single distribution with tails extending no more than 10 mm in the direction perpendicular to the magnetic field. SIGNIFICANCE: Positron range depends on positron energy and material density in which they traverse. The results show an evident improvement in image quality in the transaxial direction only, particularly in phantoms filled with68Ga when using a PET/MR system as opposed to images acquired in the PET/CT system due to the presence of the magnetic field.

10.
Artículo en Inglés | MEDLINE | ID: mdl-39009305

RESUMEN

OBJECTIVE: To analyse the efficacy of integrated assessment of [18F]F-PSMA-1007 PET/MRI on the early detection of local recurrence (LR) for prostate cancer patients with PSA levels <0.5ng/ml after radical prostatectomy. To assess the location of recurrence so that therapy may be tailored to patient. METHODS: Prospective study including 35 patients with prostate cancer (PCa), who were referred for a [18F]F-PSMA-1007 PET/MR after prostatectomy with a very initial PSA value increase (PSA<0,5ng/ml). Simultaneous acquisition in a PET/MRI hybrid equipment (SIGNA-GE), 1h after administration of 370%±10% MBq of [18F]F-PSMA-1007: Prostate selective imaging (20min): multiparametric PET+MRI (MRImp): DIXON, T1, T2, diffusion sequences post-gadolinium administration. Whole body image (30min): PET+MRI: DIXON, T1, T2, diffusion, STIR sequences. A nuclear physician and a radiologist jointly reviewed the studies: In order to assess LR, the "Prostate Imaging for Recurrence Reporting" system was used on MRI, as well as the Likert scale on the PET prostate imaging. The remaining lesions were classified as N1 and M1a. RESULTS: PET/MRI was positive in 25 patients (71,4%) and negative in 10 patients (28,6%). RL was detected in 15 patients (42.9%): in 2 (5.7%) MRI was superior; in 3 (8.6%) PET was superior; integrated PET/MRI showed improved results in 5 patients (14.3%) for the detection of LR. Location of recurrences: LR in 11 patients (44.0%); N1 in 10 (40.0%); LR+N1 (8.0%) in 2; LR+N1+M1a in 2 (8.0%). In 20 patients (80%) the PET/MRI findings allowed radioguided radiotherapy implementation (11 on LR, and 9 on N1), whereas hormonal treatment was decided in 5 patients (20%) due to multimetastases/spread disease. CONCLUSION: [18F]F-PSMA-1007 PET/MRI has a 71.4% recurrence detection rate after prostatectomy with PSA<0.5ng/ml. Its combined PET and MRI study increases the detection of LR by 14.3%, with a high N1+M1a detection rate (56%), allowing radioguided radiotherapy in 80% of patients.


Asunto(s)
Radioisótopos de Flúor , Imagen por Resonancia Magnética , Imagen Multimodal , Recurrencia Local de Neoplasia , Oligopéptidos , Tomografía de Emisión de Positrones , Antígeno Prostático Específico , Prostatectomía , Neoplasias de la Próstata , Radiofármacos , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Neoplasias de la Próstata/sangre , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/sangre , Estudios Prospectivos , Anciano , Tomografía de Emisión de Positrones/métodos , Persona de Mediana Edad , Imagen Multimodal/métodos , Radioisótopos de Flúor/farmacocinética , Antígeno Prostático Específico/sangre , Oligopéptidos/farmacocinética , Imagen por Resonancia Magnética/métodos , Niacinamida/análogos & derivados , Niacinamida/uso terapéutico , Niacinamida/farmacocinética , Imágenes de Resonancia Magnética Multiparamétrica/métodos
11.
EJNMMI Res ; 14(1): 69, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060564

RESUMEN

BACKGROUND: This study aims to evaluate the effect of various background reference regions on spinal 18F-FET PET imaging, with a focus on distinguishing between spinal tumors and myelitis. To enhance diagnostic accuracy, we investigated the pons and several other spinal cord area as potential references, given the challenges in interpreting spinal PET results. RESULTS: A retrospective analysis was conducted on 30 patients, 15 with cervical myelitis and 15 with cervical tumors, who underwent O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) PET/MR imaging. The stability of uptake across four regions, including the pons, C2, C2-C7, and T1-T3, was compared. The standardized uptake value ratio (SUVR) was then evaluated using various background regions, and their effectiveness in differentiating between spinal tumors and myelitis was compared. Additionally, we correlated the SUVR values derived from these regions with the Ki-67 proliferation index in tumor patients. The study found no significant difference in SUVmax (U = 110, p = 0.93) and SUVmean (U = 89, p = 0.35) values at lesion sites between myelitis and tumor patients. The pons had the highest average uptake (p < 0.001) compared to the other three regions. However, its coefficient of variation (CV) was significantly lower than that of the C2-C7 (p < 0.0001) and T1-T3 segments (p < 0.05). The SUVRmax values, calculated using the regions of pons, C2-C7 and T1-T3, were found to significantly differentiate between tumors and myelitis (p < 0.05). However, only the pons-based SUVRmean was able to significantly distinguish between the two groups (p < 0.05). Additionally, the pons-based SUVRmax (r = 0.63, p = 0.013) and SUVRmean (r = 0.67, p = 0.007) demonstrated a significant positive correlation with the Ki-67 index. CONCLUSIONS: This study suggests that the pons may be considered a suitable reference region for spinal 18F-FET PET imaging, which can improve the differentiation between spinal tumors and myelitis. The significant correlation between pons-based SUVR values and the Ki-67 index further highlights the potential of this approach in assessing tumor cell proliferation.

12.
J Magn Reson Imaging ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38886922

RESUMEN

BACKGROUND: Restriction spectrum imaging (RSI), as an advanced quantitative diffusion-weighted magnetic resonance imaging technique, has the potential to distinguish primary benign and malignant lung lesions. OBJECTIVE: To explore how well the tri-compartmental RSI performs in distinguishing primary benign from malignant lung lesions compared with diffusion-weighted imaging (DWI), and to further explore whether positron emission tomography/magnetic resonance imaging (PET/MRI) can improve diagnostic efficacy. STUDY TYPE: Prospective. POPULATION: 137 patients, including 108 malignant and 29 benign lesions (85 males, 52 females; average age = 60.0 ± 10.0 years). FIELD STRENGTH/SEQUENCE: T2WI, T1WI, multi-b value DWI, MR-based attenuation correction, and PET imaging on a 3.0 T whole-body PET/MR system. ASSESSMENT: The apparent diffusion coefficient (ADC), RSI-derived parameters (restricted diffusion f 1 $$ {f}_1 $$ , hindered diffusion f 2 $$ {f}_2 $$ , and free diffusion f 3 $$ {f}_3 $$ ) and the maximum standardized uptake value (SUVmax) were calculated and analyzed for diagnostic efficacy individually or in combination. STATISTICAL TESTS: Student's t-test, Mann-Whitney U test, receiver operating characteristic (ROC) curves, Delong test, Spearman's correlation analysis. P < 0.05 was considered statistically significant. RESULTS: The f 1 $$ {f}_1 $$ , SUVmax were significantly higher, and f 3 $$ {f}_3 $$ , ADC were significantly lower in the malignant group [0.717 ± 0.131, 9.125 (5.753, 13.058), 0.194 ± 0.099, 1.240 (0.972, 1.407)] compared to the benign group [0.504 ± 0.236, 3.390 (1.673, 6.030), 0.398 ± 0.195, 1.485 ± 0.382]. The area under the ROC curve (AUC) values ranked from highest to lowest as follows: AUC (SUVmax) > AUC ( f 3 $$ {f}_3 $$ ) > AUC ( f 1 $$ {f}_1 $$ ) > AUC (ADC) > AUC ( f 2 $$ {f}_2 $$ ) (AUC = 0.819, 0.811, 0.770, 0.745, 0549). The AUC (AUC = 0.900) of the combined model of RSI with PET was significantly higher than that of either single-modality imaging. CONCLUSION: RSI-derived parameters ( f 1 $$ {f}_1 $$ , f 3 $$ {f}_3 $$ ) might help to distinguish primary benign and malignant lung lesions and the discriminatory utility of f 2 $$ {f}_2 $$ was not observed. The RSI exhibits comparable or potentially enhanced performance compared with DWI, and the combined RSI and PET model might improve diagnostic efficacy. TECHNICAL EFFICACY: Stage 2.

13.
Sci Rep ; 14(1): 13950, 2024 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-38886395

RESUMEN

Tumor-to-normal ratio (T/N) measurement of 18F-FBPA is crucial for patient eligibility to receive boron neutron capture therapy. This study aims to compare the difference in standard uptake value ratios on brain tumors and normal brains using PET/MR ZTE and atlas-based attenuation correction with the current standard PET/CT attenuation correction. Regarding the normal brain uptake, the difference was not significant between PET/CT and PET/MR attenuation correction methods. The T/N ratio of PET/CT-AC, PET/MR ZTE-AC and PET/MR AB-AC were 2.34 ± 0.95, 2.29 ± 0.88, and 2.19 ± 0.80, respectively. The T/N ratio comparison showed no significance using PET/CT-AC and PET/MR ZTE-AC. As for the PET/MRI AB-AC, significantly lower T/N ratio was observed (- 5.18 ± 9.52%; p < 0.05). The T/N difference between ZTE-AC and AB-AC was also significant (4.71 ± 5.80%; p < 0.01). Our findings suggested PET/MRI imaging using ZTE-AC provided superior quantification on 18F-FBPA-PET compared to atlas-based AC. Using ZTE-AC on 18F-FBPA-PET /MRI might be crucial for BNCT pre-treatment planning.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Neoplasias Encefálicas , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Terapia por Captura de Neutrón de Boro/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/diagnóstico por imagen , Femenino , Masculino , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Encéfalo/diagnóstico por imagen , Radioisótopos de Flúor , Compuestos de Boro , Fenilalanina/análogos & derivados
14.
Phys Eng Sci Med ; 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38884672

RESUMEN

Positron Emission Tomography (PET) imaging after 90 Y liver radioembolization is used for both lesion identification and dosimetry. Bayesian penalized likelihood (BPL) reconstruction algorithms are an alternative to ordered subset expectation maximization (OSEM) with improved image quality and lesion detectability. The investigation of optimal parameters for 90 Y image reconstruction of Q.Clear, a commercial BPL algorithm developed by General Electric (GE), in PET/MR is a field of interest and the subject of this study. The NEMA phantom was filled at an 8:1 sphere-to-background ratio. Acquisitions were performed on a PET/MR scanner for clinically relevant activities between 0.7 and 3.3 MBq/ml. Reconstructions with Q.Clear were performed varying the ß penalty parameter between 20 and 6000, the acquisition time between 5 and 20 min and pixel size between 1.56 and 4.69 mm. OSEM reconstructions of 28 subsets with 2 and 4 iterations with and without Time-of-Flight (TOF) were compared to Q.Clear with ß = 4000. Recovery coefficients (RC), their coefficient of variation (COV), background variability (BV), contrast-to-noise ratio (CNR) and residual activity in the cold insert were evaluated. Increasing ß parameter lowered RC, COV and BV, while CNR was maximized at ß = 4000; further increase resulted in oversmoothing. For quantification purposes, ß = 1000-2000 could be more appropriate. Longer acquisition times resulted in larger CNR due to reduced image noise. Q.Clear reconstructions led to higher CNR than OSEM. A ß of 4000 was obtained for optimal image quality, although lower values could be considered for quantification purposes. An optimal acquisition time of 15 min was proposed considering its clinical use.

15.
Eur J Radiol ; 177: 111552, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38861905

RESUMEN

PURPOSE: The potential limitations of hepatic [18F]FDG-PET imaging for individuals with obesity and excessive liver fat (NAFLD) are being investigated. In this study, we aim to determine the reliability of standardized uptake values (SUVs) focusing on adjustment for liver fat content (LFC) derived from DIXON images and the effects of whole-body normalizations. METHODS: Lean and with obesity volunteers who underwent [18F]FDG-PET/MRI were reviewed retrospectively. DIXON fat images were used to determine LFC and for adjustment of SUVmean. The hepatic SUVs (mean, fat adjusted mean and max) were normalized to body weight, lean body mass and body surface area. Blood samples were analysed for glucose, serological liver enzymes and lipoproteins for further correlation of [18F]FDG uptake. RESULTS: Out of 11 volunteers with obesity (M:8, F:3, BMI:30-39 kg/m2), 9 confirmed the presence of NAFLD (>5.6 % fat). 22 age-matched lean volunteers (M:10, F:11, BMI:19-26 kg/m2) were used as control group. Both SUVmean, before and after adjustment to LFC, did not provide any difference between lean and with obesity groups under BW, LBM and BSA. SUVmax BW showed a difference between groups (p = 0.05). SUVs were independent of levels of GPT, GOT, gGT, insulin, HOMA-IR, triglycerides, cholesterol and LDL. Volunteers with low HDL were clustered with an increased hepatic [18F]FDG uptake. CONCLUSION: Our method for adjustment of hepatic [18F]FDG-PET with DIXON fat images allows to achieve accurate results for individuals with NAFLD and obesity. For homogenic results, raw SUVmean should be combined with adjustment for liver fat, appropriate normalization and consideration of HDL levels.


Asunto(s)
Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética , Imagen Multimodal , Enfermedad del Hígado Graso no Alcohólico , Obesidad , Tomografía de Emisión de Positrones , Radiofármacos , Humanos , Fluorodesoxiglucosa F18/farmacocinética , Masculino , Femenino , Obesidad/metabolismo , Obesidad/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Adulto , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Hígado/diagnóstico por imagen , Hígado/metabolismo
16.
Diagnostics (Basel) ; 14(9)2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38732316

RESUMEN

Oxygen-15 (ß+, t1/2 = 122 s) radiolabeled diatomic oxygen, in conjunction with positron emission tomography, is the gold standard to quantitatively measure the metabolic rate of oxygen consumption in the living human brain. We present herein a protocol for safe and effective delivery of [15O]O2 over 200 m to a human subject for inhalation. A frugal quality control testing procedure was devised and validated. This protocol can act as a blueprint for other sites seeking to implement similar imaging programs.

17.
Eur J Nucl Med Mol Imaging ; 51(11): 3440-3449, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38767660

RESUMEN

PURPOSE: To compare performance of whole-body [68Ga]Ga-FAPI-04 and [18F]FDG PET imaging in the detection of Krukenberg tumors (KTs), primary site and extra-ovarian metastases of gastric signet-ring-cell carcinoma (GSRCC), and evaluate the value of [68Ga]Ga-FAPI-04 PET/MR imaging strategy and its potential impact on the management of KTs from GSRCC. METHODS: Twelve patients with twenty-three KTs from GSRCC, who underwent both [68Ga]Ga-FAPI-04 pelvic PET/MR and whole-body [68Ga]Ga-FAPI-04 and [18F]FDG PET imaging were retrospectively analyzed. [68Ga]Ga-FAPI-04 and [18F]FDG uptakes were compared by using Wilcoxon signed-rank test or paired t test. McNemar's test was used to compare lesion detectability between two modalities. Two-tailed P<0.05 was considered statistically significant. Immunohistochemistry staining was utilized to analyze the fibroblast activation protein (FAP) expression in KTs. RESULTS: A total of 12 patients with 23 KTs from GSRCC (8 synchronous and 4 metachronous) were evaluated. [68Ga]Ga-FAPI-04 was superior to [18F]FDG PET in detecting primary sites of GSRCC (100% [11/11] vs. 18.2% [2/11], p = 0.002), involved lymph nodes (90.9% [10/11] vs. 54.5% [6/11], p = 0.046) and peritoneal metastases (100% [12/12] vs. 41.7% [5/12], p = 0.008), with higher SUVmax and TBR (all p < 0.005). Both tracers had limited value in identifying KTs, with 100% false negative rate on [68Ga]Ga-FAPI-04 PET and a low detection rate of 8.7% on [18F]FDG PET. Fap immunohistochemistry showed negative or slight FAP expression in neoplastic signet ring cells and ovarian stroma. [68Ga]Ga-FAPI-04 PET/MR imaging strategy greatly improved the detection rate of Krukenberg tumors (87%, 20/23). After adding diffusion-weighted imaging (DWI), the detection rate was further improved (87.5% vs. 100%, p = 0.083). [68Ga]Ga-FAPI-04 PET/MR imaging strategy either upgraded TNM staging or changed treatment management in twelve patients. CONCLUSIONS: [68Ga]Ga-FAPI-04 PET outperformed [18F]FDG PET in detecting primary site and most extra-ovarian metastases of GSRCC, but both tracers had limited value in identifying Krukenberg tumors. Pelvis MRI should be applied to compensate the limitation of [68Ga]Ga-FAPI-04 PET imaging to identify Krukenberg tumours. The [68Ga]Ga-FAPI-04 PET/MR imaging strategy has the potential to impact treatment decisions for GSRCC patients with KTs.


Asunto(s)
Carcinoma de Células en Anillo de Sello , Tumor de Krukenberg , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Neoplasias Gástricas , Humanos , Femenino , Persona de Mediana Edad , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/patología , Tumor de Krukenberg/diagnóstico por imagen , Carcinoma de Células en Anillo de Sello/diagnóstico por imagen , Adulto , Tomografía de Emisión de Positrones/métodos , Anciano , Imagen Multimodal/métodos , Estudios Retrospectivos , Fluorodesoxiglucosa F18 , Masculino , Quinolinas
18.
ACS Appl Mater Interfaces ; 16(21): 27139-27150, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38752591

RESUMEN

Diagnosing of lymph node metastasis is challenging sometimes, and multimodal imaging offers a promising method to improve the accuracy. This work developed porphyrin-based nanoparticles (68Ga-F127-TAPP/TCPP(Mn) NPs) as PET/MR dual-modal probes for lymph node metastasis imaging by a simple self-assembly method. Compared with F127-TCPP(Mn) NPs, F127-TAPP/TCPP(Mn) NPs synthesized by amino-porphyrins (TAPP) doping can not only construct PET/MR bimodal probes but also improve the T1 relaxivity (up to 456%). Moreover, T1 relaxivity can be adjusted by altering the molar ratio of TAPP/TCPP(Mn) and the concentration of F127. However, a similar increase in T1 relaxivity was not observed in the F127-TCPP/TCPP(Mn) NPs, which were synthesized using carboxy-porphyrins (TCPP) doping. In a breast cancer lymph node metastasis mice model, subcutaneous injection of 68Ga-F127-TAPP/TCPP(Mn) NPs through the hind foot pad, the normal lymph nodes and metastatic lymph nodes were successfully distinguished based on the difference of PET standard uptake values and MR signal intensities. Furthermore, the dark brown F127-TAPP/TCPP(Mn) NPs demonstrated the potential for staining and mapping lymph nodes. This study provides valuable insights into developing and applying PET/MR probes for lymph node metastasis imaging.


Asunto(s)
Metástasis Linfática , Imagen por Resonancia Magnética , Nanopartículas , Porfirinas , Tomografía de Emisión de Positrones , Ganglio Linfático Centinela , Animales , Porfirinas/química , Nanopartículas/química , Ratones , Metástasis Linfática/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Femenino , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/patología , Humanos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Ratones Endogámicos BALB C , Línea Celular Tumoral
19.
J Cancer Res Clin Oncol ; 150(5): 272, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38795250

RESUMEN

PURPOSE: Somatostatin receptor (SSTR)-targeted PET imaging has emerged as a common approach to evaluating those patients with well-differentiated neuroendocrine tumors (NETs). The SSTR reporting and data system (SSTR-RADS) version 1.0 provides a means of categorizing lesions from 1 to 5 according to the likelihood of NET involvement, with SSTR-RADS-3A (soft-tissue) and SSTR-RADS-3B (bone) lesions being those suggestive of but without definitive NET involvement. The goal of the present study was to assess the ability of 68Ga-DOTATATE PET/MR imaging data to predict outcomes for indeterminate SSTR-RADS-3A and 3B lesions. METHODS: NET patients with indeterminate SSTR-RADS-3A or SSTR-RADS-3B lesions who underwent 68Ga-DOTATATE PET/MR imaging from April 2020 through August 2023 were retrospectively evaluated. All patients underwent follow-up through December 2023 (median, 17 months; (3-31 months)), with imaging follow-up or biopsy findings ultimately being used to classify lesions as malignant or benign. Lesion maximum standardized uptake value (SUVmax) along with minimum and mean apparent diffusion coefficient (ADCmin and ADCmean) values were measured and assessed for correlations with outcomes on follow-up. RESULTS: In total, 33 indeterminate SSTR-RADS-3 lesions from 22 patients (19 SSTR-RADS-3A and 14 SSTR-RADS-3B) were identified based upon baseline 68Ga-DOTATATE PET/MR findings. Over the course of follow-up, 16 of these lesions (48.5%) were found to exhibit true NET positivity, including 9 SSTR-RADS-3A and 7 SSTR-RADS-3B lesions. For SSTR-RADS-3A lymph nodes, a diameter larger than 0.7 cm and an ADCmin of 779 × 10-6mm2/s or lower were identified as being more likely to be associated with metastatic lesions. Significant differences in ADCmin and ADCmean were identified when comparing metastatic and non-metastatic SSTR-RADS-3B bone lesions (P < 0.05), with these parameters offering a high predictive ability (AUC = 0.94, AUC = 0.86). CONCLUSION: Both diameter and ADCmin can aid in the accurate identification of the nature of lesions associated with SSTR-RADS-3A lymph nodes, whereas ADCmin and ADCmean values can inform the accurate interpretation of SSTR-RADS-3B bone lesions.


Asunto(s)
Tumores Neuroendocrinos , Compuestos Organometálicos , Receptores de Somatostatina , Humanos , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/patología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Receptores de Somatostatina/metabolismo , Adulto , Tomografía de Emisión de Positrones/métodos , Imagen por Resonancia Magnética/métodos , Radiofármacos , Anciano de 80 o más Años , Pronóstico
20.
Alzheimers Dement ; 20(6): 3876-3888, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38634334

RESUMEN

INTRODUCTION: Metabotropic glutamate receptor 5 (mGluR5) is involved in regulating integrative brain function and synaptic transmission. Aberrant mGluR5 signaling and relevant synaptic failure play a key role in the pathophysiological mechanism of Alzheimer's disease (AD). METHODS: Ten cognitively impaired (CI) individuals and 10 healthy controls (HCs) underwent [18F]SynVesT-1 and [18F]PSS232 positron emission tomography (PET)/magnetic resonance to assess synaptic density and mGluR5 availability. The associations between mGluR5 availability and synaptic density were examined. A mediation analysis was performed to investigate the possible mediating effects of mGluR5 availability and synaptic loss on the relationship between amyloid deposition and cognition. RESULTS: CI patients exhibited lower mGluR5 availability and synaptic density in the medial temporal lobe than HCs. Regional synaptic density was closely associated with regional mGluR5 availability. mGluR5 availability and synaptic loss partially mediated the relationship between amyloid deposition and cognition. CONCLUSIONS: Reductions in mGluR5 availability and synaptic density exhibit similar spatial patterns in AD and are closely linked. HIGHLIGHTS: Cognitively impaired patients exhibited lower mGluR5 availability and synaptic density in the medial temporal lobe than HCs. Reductions in mGluR5 availability and synaptic density exhibit similar spatial patterns in AD. Regional synaptic density was closely associated with regional mGluR5 availability. mGluR5 availability and synaptic loss partially mediated the relationship between amyloid deposition and global cognition. With further research, modulating mGluR5 availability might be a potential therapeutic strategy for improving synaptic function in AD.


Asunto(s)
Disfunción Cognitiva , Tomografía de Emisión de Positrones , Receptor del Glutamato Metabotropico 5 , Humanos , Receptor del Glutamato Metabotropico 5/metabolismo , Masculino , Disfunción Cognitiva/metabolismo , Disfunción Cognitiva/diagnóstico por imagen , Disfunción Cognitiva/patología , Femenino , Anciano , Enfermedad de Alzheimer/metabolismo , Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/patología , Imagen por Resonancia Magnética , Sinapsis/metabolismo , Sinapsis/patología , Persona de Mediana Edad , Encéfalo/metabolismo , Encéfalo/diagnóstico por imagen , Encéfalo/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA