Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 555
Filtrar
1.
Clin Optom (Auckl) ; 16: 223-231, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39246672

RESUMEN

Purpose: Risk factors for presbyopia have not been fully determined although previous studies suggested presbyopia was associate with age, dry eye, and retinal ganglion cell complex thickness (GCC). We accessed these signs and common ocular symptoms in the middle-aged population focusing on sex differences when women have drastic hormonal change. Methods: This cohort study consecutively enrolled 2743 patients aged 36-45 years (n=1000), 46-55 years (n=1000), and 56-65 years (n=743). All underwent ocular surface tests and had near add power and GCC measured. Common ocular symptoms were asked using questionnaire. Results: Among female participants, visual symptoms (eye strain and photophobia) were more prevalent in the age group 46-55, whereas non-visual symptoms (dryness, irritation, and pain) were not. We identified symptomatic presbyopia (near add power ≥ 1.5D) in 14.4%, 73.8%, and 97.8%, positive corneal staining in 29.1%, 23.8%, and 23.9%, and a mean GCC of 98.2 µm, 105.3 µm, and 89.6 µm in the age groups 36-45, 46-55, and 56-65, respectively. Mean tear break-up time were 3.3, 3.5, and 3.3 seconds, respectively. Results indicated a large progression of presbyopia (P<0.01) from the period of 36-45 years onward and significantly increased GCC (P<0.01) in women of age group 46-55. No notable tendency was observed in symptoms and GCC for male participants. Conclusion: Visual symptoms in women were worse between 46 and 55 years than before or after these ages. The increase of symptomatic presbyopia and GCC may be contributing to visual symptoms in addition to menopausal transition symptoms in this age group.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39250191

RESUMEN

PURPOSE: Investigations into the correction of presbyopia have considered lens design, clinical implications and the development of objective metrics such as the visual Strehl ratio. This study investigated the Jacobi-Fourier phase mask as an ophthalmic element in the correction of presbyopia. The goal was to develop a contact or intraocular lens whose performance was largely insensitive to changes in pupil diameter. METHODS: Numerical simulations based on Fourier optics were performed to evaluate three different Jacobi-Fourier polynomials, with the aim of providing a range of clear vision (1 Dioptre (D)). Performance was evaluated for three pupil sizes (6, 4 and 2 mm), while polychromatic images were simulated using three different wavelengths (656.3, 587.6 and 486.1 nm). The Neural Transfer function was included in the simulation. To validate the method and results, we used the Visual Strehl combined objective metric (VSCombined) currently used in visual optics. This metric gives more weight to the phase transfer function and is more suitable for non-symmetrical phase functions. RESULTS: Numerical validation showed the suitability of the Jacobi-Fourier phase masks for extending the range of clear vision of presbyopic eyes, providing a visual acuity of at least 0.10 logMAR (6/7.5 Snellen) at all distances between 1 and 6 m. The results show a range of clear vision of 1D was not affected by changes in pupil size, an increase in retinal image contrast accompanied by image artefact reduction by increasing the radial order of the Jacobi-Fourier phase mask and a reduction of wavelength dependence of the retinal images. These results are supported by simulated images and the objective criterion VSCombined. CONCLUSIONS: The use of Jacobi-Fourier phase masks as ophthalmic elements for presbyopic correction show promising results, with a good range of clear vision and reduced dependence on pupil size and chromatic aberration.

3.
Artículo en Inglés | MEDLINE | ID: mdl-39243285

RESUMEN

OBJECTIVE: To evaluate changes in choroidal thickness in presbyopes, when reading with regular glasses versus choroidal control glasses, in patients with or without Age-Related Macular Degeneration (AMD). METHODS: This was a pilot study on short-term axial length (AL) in 33 eyes of 24 presbyopic patients aged 60 to 80 years, assigned to two age-matched groups, with or without AMD. About them, changes in choroidal thickness were evaluated with ocular biometry through indirect measurements of axial length at baseline, after 20' of reading with conventional lenses, and after another 20' of reading with peripheral hyperopic defocus glasses. The differences in axial length between the three different times were analyzed. RESULTS: In presbyopes without AMD there was a significant axial length shortening of -13.44 microns in the first conventional reading period, which was reversed by 90% with hyperopic defocus lenses, recovering + 12.11 microns by axial lengthening (choroidal thinning, p = 0.03). In patients with AMD, axial shortening was significantly greater than controls, -23.86 microns with conventional lenses (p < 0.001) and they, also increased their axial length with defocus, although this response was smaller in proportion (+ 15.52 microns). CONCLUSION: Reading with positive lenses produces myopic defocus and choroidal thickening in presbyopes with and without AMD but was significantly greater in the latter. Glasses with Choroidal Control Technology reduced thickening during reading. KEY MESSAGES: What is known • Presbyopia spectacles for near produce myopic defocus and choroidal thickening. What is new • There are differences in choroidal thickening during reading between normal subjects and those with age related macular degeneration. • Spectacles with Defocus Choroidal Control Technology reduce choroidal thickening during reading in presbyopes.

4.
Front Med (Lausanne) ; 11: 1462205, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39247637

RESUMEN

Background: Residual astigmatism is common after cataract surgery involving implantation of an intraocular lens, yet the tolerance of presbyopia-correcting intraocular lens to astigmatism of different magnitudes and axes is poorly understood. Here we compared visual acuity and quality in the presence of induced astigmatism after implantation of a trifocal or extended-depth-of-focus (EDOF) intraocular lens, the two widely used presbyopia-correcting intraocular lenses. Methods: At least 3 months after implantation of a TFNT00 or ZXR00 intraocular lens, patients were analyzed by slit-lamp examination, non-contact tonometry, subjective refraction, iTrace aberrometry, and corneal topography. After correction of residual astigmatism, astigmatism of different magnitudes on different axes was induced using cylindrical lenses, and overall visual acuity was measured, while objective visual quality was measured using the Optical Quality Analysis System II. Subjects were also asked about subjective visual quality using the Visual Function-14 questionnaire. Results: Comparison of 18 individuals who received a trifocal lens and 19 who received an EDOF lens showed that objective visual quality was better in the EDOF group regardless of the magnitude or axis of the induced astigmatism. In both groups, astigmatism of at least -1.00 DC influenced distant vision more severely when the axis was 45° than 0° or 90°, meanwhile astigmatism of at least -1.50 DC influenced near and intermediate vision more severely when the axis was 45° than 0° or 90°. Conclusion: Trifocal or EDOF intraocular lenses are less tolerant of oblique astigmatism than astigmatism with or against the rule. EDOF lenses may provide better objective visual quality than trifocal lenses in the presence of astigmatism, regardless of its magnitude or axis.

5.
Clin Optom (Auckl) ; 16: 191-199, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39100731

RESUMEN

Purpose: To assess public awareness and knowledge about presbyopia and their compliance to ocular examination in Jordan. Patients and Methods: A cross-sectional survey was designed to interview people in different provinces of Jordan. Socio-demographic data such as age, gender and level of education and region was reported. The first part of the questionnaire assessed awareness of presbyopia in terms of the need for spectacles with age, age of onset, possible causes of presbyopia and methods of presbyopia management. The second part of the questionnaire evaluated compliance of the participants with ocular examination in terms of frequency and motive to do general eye check, intraocular pressure (IOP), fundus exam and visual acuity. Results: A total of 802 participants (232 males, 570 females) with an average age of 28 (±11.6) completed the questionnaire. Most participants (84.2%) knew that glasses are needed for near vision as age increases, and 62.8% estimated the age at which spectacles are required (40 years or older). Over half understood that presbyopia is correctable and progressive. Age significantly influenced knowledge about the need for near vision spectacles, and whether presbyopia is preventable and progressive (both p < 0.05). Females were more knowledgeable about these aspects. The frequency of eye examinations, particularly fundus exams and IOP tests, was significantly influenced by age but not by education. Gender only significantly affected the frequency of vision checks (p = 0.01), with females being more likely to adhere to them. Conclusion: This study demonstrated a good level of awareness and knowledge about presbyopia among Jordanians, especially those over 40 and females. Regular eye check-ups were more common among young participants and females. Addressing misconceptions about presbyopia's preventability and promoting regular eye exams are crucial for early diagnosis and management of presbyopia and other serious eye conditions.

6.
Ophthalmol Ther ; 13(9): 2331-2341, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39095681

RESUMEN

Recent advancements in cataract surgery have broadened its scope from mere vision restoration to include correction of refractive errors and presbyopia. This evolution has introduced multifocal and extended depth-of-focus (EDOF) intraocular lenses (IOLs), allowing enhanced vision across multiple distances. However, the influence of these advanced IOLs on stereopsis remains controversial. Factors influencing stereopsis after surgery include visual acuity, interocular differences, residual astigmatism, and the type of IOL, etc. Binocular vision integration and neuroadaptation further affect stereopsis, especially in cases of presbyopia-correcting IOLs. It is widely acknowledged that bilateral implantation of presbyopia-correcting IOLs yield superior stereopsis compared to unilateral implantation. However, there remains no consensus on whether binocular implantation of multifocal or monofocal IOLs provides superior stereopsis. Most studies suggest no significant difference in stereopsis between these two types of implants. Among different types of multifocal IOLs, refractive multifocal IOLs may offer better stereopsis than diffractive multifocal IOLs when implanted bilaterally. Emerging EDOF and hybrid multifocal-EDOF IOLs also demonstrate promising postoperative stereopsis. Additionally, a mix-and-match strategy with different types of IOLs implanted in each eye may result in interocular differences in visual acuity at certain distances, potentially affecting stereopsis. Nevertheless, with appropriate selection, most patients can achieve satisfactory postoperative stereopsis. This review synthesizes current literature on the effects of presbyopia-correcting IOLs on postoperative stereopsis recovery following cataract surgery. Studies on stereopsis outcomes with different IOLs have yielded mixed results, urging further investigation for optimized surgical strategies and patient outcomes.

7.
Ophthalmol Ther ; 2024 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-39153117

RESUMEN

INTRODUCTION: Pinhole intraocular lenses (IOLs) were developed to improve reading by compensating for loss of accommodative function. The IC-8® Apthera™ is a small-aperture presbyopia-correcting IOL that combines the proven principle of small-aperture optics with an aspheric monofocal lens to deliver a continuous range of vision for patients with cataracts from distance to near vision. Posterior capsule opacification is the most common sequela after cataract surgery. It is effectively treated by laser capsulotomy. However, if the laser beam is incorrectly focused, the IOL can be permanently damaged (pits/shots). METHODS: In this experimental study, yttrium-aluminum-garnet (YAG) pits were purposefully created. Defects were analyzed and compared between the periphery of the ring in the clear area of the hydrophobic acrylic lens and at the carbon black (CB)-polyvinylidene fluoride (PVDF) filtering component (FilterRing™) of the pinhole lens. All defects were made using identical settings/energy levels (2.6 mJ). The damage induced to the IC-8® Apthera™ IOL was examined by low-magnification images, light microscopy, scanning electron microscopy, and micro-computed tomography (micro-CT). RESULTS: YAG defects in the carbon black filter ring were much more severe than those in the clear zone due to the high absorption of the carbon black. Massive defects and destruction of the lens with tearing out of fragments and particles were observed. The missing volume calculated from the micro-CT reconstruction was 0.266 mm3, which is 1.6% of the entire IOL volume, or more than 1000 times the volume damaged in the largest shot in the periphery. CONCLUSION: Based on the results, we highly recommend using the lowest possible energy levels, posterior offset setting, and circular pattern for maximum safety when performing laser capsulotomy with pinhole implants. Care should be taken to avoid creating irreversible iatrogenic defects that may affect overall quality. The safest area for performing capsulotomy seems to be the periphery of the ring segment. Video available for this article.

8.
Cont Lens Anterior Eye ; 47(4): 102191, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39098809

RESUMEN

The aging eye undergoes the same progressive crosslinking which occurs throughout the body, resulting in increased rigidity of ocular connective tissues including the lens and the sclera which impact ocular functions. This offers the potential for a scleral treatment that is based on restoring normal biomechanical movements. Laser Scleral Microporation is a laser therapy that evaporates fractional areas of crosslinked tissues in the sclera, reducing ocular rigidity over critical anatomical zones of the accommodation apparatus, restoring the natural dynamic range of focus of the eye. Although controversial and challenged, an alternative theory for presbyopia is Schachar's theory that suggests a reduction in the space between the ciliary processes and the crystalline lens. Widening of this space with expansion bands has been shown to aid near vision in people with presbyopia, a technique that has been used in the past but seems to be obsolete now. The use of drugs has been used in the treatment of presbyopia, either to cause pupil miosis to increase depth of focus, or an alteration in refractive error (to induce myopia in one eye to create monovision). Drugs and laser ablation of the crystalline lens have been used with the aim of softening the hardened lens. Poor nutrition and excess exposure to ultraviolet light have been implicated in the onset of presbyopia. Dietary nutritional supplements, lifestyle changes have also been shown to improve accommodation and the question arises whether these could be harnessed in a treatment for presbyopia as well.


Asunto(s)
Presbiopía , Esclerótica , Presbiopía/terapia , Presbiopía/fisiopatología , Humanos , Cristalino , Terapia por Láser/métodos , Acomodación Ocular/fisiología
9.
Turk J Ophthalmol ; 54(4): 190-197, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39205393

RESUMEN

Objectives: It was aimed to compare the clinical results of the mini-monovision technique (MMV) with enhanced monofocal intraocular lens (IOL) and trifocal IOL applications and to evaluate the intereye differences in the MMV group. Materials and Methods: This retrospective observational study evaluated the results of cataract surgeries performed on 48 eyes of 24 patients. Surgeries in Group I were performed for MMV using the RayOne EMV IOL targeting emmetropia in dominant eyes (Group IA) and -0.70 diopter (D) myopia in non-dominant eyes (Group IB), while those in Group II were performed with the AcrySof® IQ PanOptixTM TNFT00 IOL targeting emmetropia. After the surgeries, uncorrected and corrected distance, intermediate, and near distance visual acuities, contrast sensitivity measurements, and defocus curves were determined. Subjective evaluation was made with the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). The groups were compared statistically. Results: Postoperative refraction mean spherical equivalent was -0.25±0.22 D, -0.67±0.33 D, and -0.16±0.31 D in the three groups, respectively. A statistical difference was identified in favor of Group IA for uncorrected distance vision and in favor of Group IB for near vision (p<0.05). There was no difference in bilateral uncorrected visions in Groups I and II (p>0.05). While contrast sensitivity was better in Group I at all spatial frequencies (p<0.05), better vision was achieved in the defocus curve at distance in Group IA and at near in Group IB. In the binocular evaluation, it was seen that Groups I and II had similar results. In the subjective evaluation, NEI-VFQ-25 scores were 94.1±4.2/100 in Group I and 91.5±3.0/100 in Group II at 6 months (p>0.05). Photic complaints were significantly more common in Group II. Conclusion: With the MMV technique, it was observed that enhanced monofocal lenses provided better visual acuity at all distances and less dysphotopsia than trifocal lenses, whereas trifocal lenses were better at providing independence from glasses.


Asunto(s)
Lentes Intraoculares , Lentes Intraoculares Multifocales , Diseño de Prótesis , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Persona de Mediana Edad , Anciano , Facoemulsificación/métodos , Seudofaquia/fisiopatología , Resultado del Tratamiento , Implantación de Lentes Intraoculares/métodos , Estudios de Seguimiento , Sensibilidad de Contraste/fisiología , Visión Binocular/fisiología
10.
Jpn J Ophthalmol ; 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39215880

RESUMEN

PURPOSE: There is limited evidence to evaluate the numerical cutoff point for detecting early presbyopia. Thus, we aimed to establish a clinically relevant optimal cutoff value of near visual acuity for detecting early presbyopia. STUDY DESIGN: Prospective diagnostic accuracy study. METHODS: We included consecutive individuals aged ≥ 20 years with a binocular-corrected distance visual acuity of ≥ 20/25 who did not undergo ophthalmic surgery between December 17, 2020 and December 19, 2021, at two healthcare facilities in Japan. Binocular distance-corrected near visual acuity at 40 cm, accommodative amplitude, awareness of presbyopia, and Near Activity Visual Questionnaire scores were examined. The optimal cutoff values of distance-corrected near visual acuity for diagnosing early presbyopia were evaluated using receiver operating characteristic plots. RESULTS: Among 115 participants, 74 (64.3%) had presbyopia. The proportion of participants with no difficulty performing near-vision tasks decreased markedly when near visual acuity decreased to 20/20 (> 0.00 logMAR). A cutoff value of 0.00 logMAR for distance-corrected near visual acuity was optimal, showing high sensitivity of 56.76% and specificity of 92.68%, as opposed to the commonly used cutoff value of 0.40 logMAR (20/50; sensitivity, 9.46% and specificity, 100%) for diagnosing early presbyopia. CONCLUSION: Near visual acuity of 0.00 logMAR (20/20) could be the optimal cutoff value for diagnosing early presbyopia.

11.
BMC Ophthalmol ; 24(1): 320, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090592

RESUMEN

BACKGROUND: The visual performance and the optical quality of a segmental refractive extended depth-of-focus (EDoF) intraocular lens (IOL) were evaluated in a prospective, single-arm, single-center study. METHODS: A total of 20 patients (40 eyes) after bilateral implantation of the refractive segmental EDoF Acunex Vario AN6V were included. Assessment procedure: refraction outcome, monocular and binocular uncorrected (UCVA) and distance-corrected visual acuity (DCVA), defocus curve, contrast sensitivity (CS), higher-order aberrations (HOAs) and patient satisfaction were evaluated 1 and 3 months after surgery. RESULTS: At 3-month follow-up, mean spherical equivalent was - 0.23 ± 0.32 D. Binocular uncorrected distance visual acuity (VA) at distance, intermediate and near was - 0.08 ± 0.06 logMAR at 4 m, -0.03 ± 0.06 logMAR at 66 cm and 0.16 ± 0.06 logMAR at 40 cm, respectively. The binocular defocus curve showed a VA better than 0.20 logMAR over a range from + 1.50 to - 2.45 D. Contrast sensitivity aligned with monofocal lenses, highlighting the lens's clinical value. Aberrometry showed minimal changes in corneal aberrations. NEI-RQL-42-Questionnaire showed a high patient satisfaction for daily activities and revealed reduced dependence on glasses, particularly for near and intermediate vision. The Acunex Vario AN6V demonstrated minimal dysphotopsias, making it a promising option for those seeking spectacle independence. CONCLUSION: This segmental refractive EDoF IOL provides a high degree of spectacle independence for far and intermediate distances with functional near VA. Although inducing residual coma aberrations, it showed subjectively good results with little dysphotopsias. TRIAL REGISTRATION: This study protocol was reviewed and approved by ethics committee of Charité University, Berlin, Germany, with approval number EA4/126/20.


Asunto(s)
Sensibilidad de Contraste , Lentes Intraoculares , Satisfacción del Paciente , Seudofaquia , Refracción Ocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Femenino , Estudios Prospectivos , Masculino , Persona de Mediana Edad , Refracción Ocular/fisiología , Anciano , Sensibilidad de Contraste/fisiología , Seudofaquia/fisiopatología , Diseño de Prótesis , Facoemulsificación , Implantación de Lentes Intraoculares/métodos , Percepción de Profundidad/fisiología , Visión Binocular/fisiología , Estudios de Seguimiento
12.
Bioinformation ; 20(5): 532-536, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39132245

RESUMEN

Pharmacological treatment of presbyopia-spectacle free senescence Therefore, it is of interest to estimate improvement of near vision with 0.5%pilocarpine drops in presbyopic patients. It was a cross-sectional observational study done at tertiary care centre history, comprehensive eye examination, including distant visual acuity distant and near vision, IOP. 1 drop of 0.5%Pilocarpine eye-drops was instilled in both eyes in Patients with full distant vision and impaired near vision, near vision was checked after 2hours. Among 55 participants, 48% were males and 52% were females. Mean age of patients was 44.8 years. Out of 55 patients 58% patients showed improvement of 1 line after instilling drops, 41% patients showed no improvement. Topical 0.5%pilocarpine in treatment of near vision is attractive option for patients and would increase compliance with minimal side effects.

13.
BMC Public Health ; 24(1): 1950, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39033287

RESUMEN

BACKGROUND: This study investigated patients' awareness of presbyopia and its management approaches and their preferred methods for near vision correction. METHODS: In Saudi Arabia, 785 participants (aged between 35 and 60 years) completed a structured survey online, consisting of hard copies and direct interviews. The survey consisted of twenty-eight items divided into three parts. It was designed to record participants' awareness of and preferences for presbyopia and its refractive corrections. Nonparametric tests and descriptive analyses were conducted to analyse participants' responses. RESULT: Approximately half of the participants had difficulty with near vision activities, such as reading newspapers or using mobile phones. Among all the participants, 76% were not aware of presbyopia. The prevalence of uncorrected presbyopia was 48% of the 785. The majority (82%) felt that spectacles were acceptable for correction of presbyopia. Most reported that they did not experience social stigma when using reading spectacles (87% of participants). When asked if they were aware of management approaches other than spectacles, 72% responded with not at all. Most participants had no earlier knowledge of the use of multifocal contact lenses or eye drops for presbyopia correction (67% and 82%, respectively). In the present study, some tendencies to use corrective approaches to presbyopia other than spectacles were noted. Finally, participants' age, sex, region, education, and income had a statistically significant impact on essential parts of their responses (p < 0.05). CONCLUSION: Presbyopia is a highly prevalent age-related ocular disorder, and a significant percentage of cases are uncorrected due to a lack of awareness or reluctance to wear spectacles. More efficient health education about presbyopia and its corrective alternatives is urgently needed.


Asunto(s)
Conocimientos, Actitudes y Práctica en Salud , Presbiopía , Humanos , Presbiopía/terapia , Presbiopía/psicología , Presbiopía/epidemiología , Arabia Saudita , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anteojos/estadística & datos numéricos , Encuestas y Cuestionarios
14.
Vestn Oftalmol ; 140(3): 70-74, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38962981

RESUMEN

PURPOSE: This study evaluates the effectiveness of implantation of extended depth of focus (EDOF) intraocular lenses (IOL) in patients with cataract and glaucoma. MATERIAL AND METHODS: The study included 13 patients (16 eyes) who underwent implantation of the Lentis Comfort EDOF IOL (Teleon Surgical BV, Netherlands). Standard phacoemulsification cataract surgery with IOL implantation was performed in a planned manner after the hypotensive surgery stage in two eyes; a combined procedure was performed in 14 cases. Uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), near visual acuity, and intraocular pressure (IOP) measured with a Maklakov tonometer were assessed preoperatively, on the first day, and 3-6 months after surgery. Computer perimetry using the 30-2 program and spatial contrast sensitivity (SCS) assessment were also performed preoperatively and at the same follow-up time points. RESULTS: On the first day after surgery, UCVA was 0.53±0.65, BCVA was 0.85±0.45. Near UCVA (at 40 cm) was 0.5±0.14 on the first day after surgery and 0.56±0.18 at 3-6 months. According to computer perimetry data, retinal light sensitivity values increased in all patients in the long-term (-3.1±2.9 dB). SCS values increased for objects of all sizes compared to preoperative values. CONCLUSION: Implantation of EDOF IOL contributes to improved vision without reducing contrast sensitivity and retinal light sensitivity in patients with concomitant cataract and glaucoma.


Asunto(s)
Glaucoma , Implantación de Lentes Intraoculares , Lentes Intraoculares , Agudeza Visual , Humanos , Femenino , Masculino , Anciano , Implantación de Lentes Intraoculares/métodos , Glaucoma/cirugía , Glaucoma/fisiopatología , Persona de Mediana Edad , Facoemulsificación/métodos , Resultado del Tratamiento , Presión Intraocular/fisiología , Catarata/complicaciones , Catarata/fisiopatología , Sensibilidad de Contraste/fisiología , Diseño de Prótesis
15.
Med Mol Morphol ; 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38980406

RESUMEN

The prevalence of presbyopia and nuclear cataracts (NUC) is reported to be higher in tropical areas than that in other regions, suggesting a potential influence of high temperatures on lens health. Transient receptor potential vanilloid (TRPV) channels play a crucial role in detecting ambient temperatures across various species, with TRPV1 and TRPV4 expressed in lens epithelial cells. In this study, we investigated whether ambient temperatures affect TRPV1 and TRPV4 activity in the lens, potentially contributing to the development of presbyopia and NUC. We conducted experiments using cultured human lens epithelial cell lines under different temperature conditions. Our results revealed that the mitogen-activated protein kinase (MEK)/extracellular signal-regulated kinase (ERK) and p38 pathways, downstream molecules of TRPV1, were activated, while Src family kinase, a downstream molecule of TRPV4, was inhibited at 37.5 °C culture compared to 35.0 °C. Confocal microscope images demonstrated higher expression of TRPV1 in 3D-structured cells under high-temperature culture conditions. Additionally, in organ culture lenses, higher elasticity was observed at elevated temperatures compared to that at lower temperatures. These results suggest that high ambient temperatures may induce lens sclerosis via TRPV1 activation, potentially contributing to the development of presbyopia and NUC.

16.
Clin Ophthalmol ; 18: 2113-2123, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39055378

RESUMEN

Purpose: Employing "relative plus" (Add) power to extend the functional vision range is a primary method to correct presbyopia with contact lenses. Simultaneous vision contact lenses are typically associated with visual disturbances at higher Add powers, often resulting in compromised vision and necessitating specialized fitting methods. Among mature individuals suffering from presbyopia, we evaluated the visual performance of a catenary curve-based extended depth of focus (EDOF) optical profile contact lens with a simplified fitting process. Methods: Mature individuals suffering from presbyopia with Add requirements of +2.00 D or more were recruited. Monocular and binocular visual acuities were obtained across optical vergences ranging from -4.00 D to +2.00 D to generate defocus curves for best spectacle-corrected distance vision (baseline) and center-distance, catenary curve-based contact lenses (catenary). A subjective questionnaire evaluating the lenses was employed. Results: Twenty-four mature individuals suffering from presbyopia, average age 59.2 (range: 51-68 years) and average Add requirement of +2.24 D (range +2.00 D to +2.50 D) were enrolled. Under high-contrast conditions, the catenary lens provided functional binocular vision (0.30 logMAR or better) at all optical vergences from distance to -3.50 D (equivalent to 28 cm). Participants demonstrated a significant improvement (p < 0.05) in binocular visual acuity while wearing the catenary lens with an imposed defocus of -1.50 D to -4.00 D (equivalent to object distances from 66 cm to 25 cm). Subjective ratings with the catenary lens were equivalent to those documented at baseline. Conclusion: The catenary curve-based lenses provided a full range of functional vision while maintaining clear distance vision for individuals suffering from advanced presbyopia. Comparison with previous results involving this lens indicates that these findings are also generalizable to wearers with lower Add requirements. This EDOF design provides a universal Add which is sufficient for advanced presbyopia. Trial Registration: ClinicalTrials.gov. Identifier: NCT05495971.

17.
Int Ophthalmol ; 44(1): 334, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39046597

RESUMEN

PURPOSE: To evaluate the clinical outcomes following bilateral implantation of the AcrySof™ IQ Vivity™ toric extended depth of focus (EDOF) intraocular lens (IOL). DESIGN: Prospective interventional case series. METHODS: Patients with bilateral significant cataracts and pre-existing corneal astigmatism underwent cataract surgery and implantation with the AcrySof™ IQ Vivity™ toric IOL. Dominant eyes were targeted at emmetropia and non-dominant eyes at -0.50D. Primary endpoints were binocular uncorrected distance (UDVA), intermediate (UIVA at 66 cm) and near (UNVA at 40 cm) acuities at 3 months. Secondary outcomes were corrected distance (CDVA), distance corrected intermediate (DCIVA) and distance corrected near (DCNVA), refractive predictability, rotational stability, binocular defocus curve, contrast sensitivity, Questionnaire for Visual Disturbances (QUVID) and Visual Function Index (VF-14) questionnaire scores. All visual acuities were converted to logarithm of minimum angle of resolution (logMAR) for analysis. RESULTS: 30 patients underwent uneventful phacoemulsification. The mean binocular UDVA, UIVA and UNVA were 0.06 ± 0.12, 0.11 ± 0.10 and 0.26 ± 0.10 respectively. The mean refractive spherical equivalent (MRSE) for dominant and non-dominant eyes were - 0.07D ± 0.27 and - 0.12D ± 0.54 respectively. 92.4% of dominant eyes and 84.6% of non-dominant eyes within 0.50D of target. The mean IOL rotation was 3.85° ± 5.09 with 86.7% of eyes with less than 5° of rotation. 26.7%, 20% and 36.7% of patients reported starbursts, haloes and glare respectively. The mean VF-14 score was 91.77. CONCLUSION: Bilateral implantation of the AcrySof™ IQ Vivity™ Toric IOL resulted in very good unaided visual acuities for far and intermediate distance with functional near vision. Dysphotopsias were reported but despite this, a high level of visual function was achieved.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Visión Binocular , Agudeza Visual , Humanos , Estudios Prospectivos , Masculino , Femenino , Anciano , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Visión Binocular/fisiología , Facoemulsificación/métodos , Refracción Ocular/fisiología , Diseño de Prótesis , Percepción de Profundidad/fisiología , Anciano de 80 o más Años , Resultado del Tratamiento , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Catarata/complicaciones , Catarata/fisiopatología
18.
BMC Ophthalmol ; 24(1): 305, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39044126

RESUMEN

BACKGROUND: Addressing presbyopia in the aging population, particularly in non-cataractous patients, remains a challenge. This study evaluates the outcomes of refractive lens exchange (RLE) with AT LISA tri 839MP trifocal intraocular lens (IOL) implantation in a Chinese presbyopic population without cataracts. METHODS: The study included 164 eyes from 82 patients undergoing bilateral RLE at Peking Union Medical College Hospital. Comprehensive evaluations encompassed visual acuities, refraction, ocular aberrometry, and subjective outcomes via the VF-14 questionnaire. The focus was on postoperative visual performance, refractive outcomes, safety, objective optical quality, and patient satisfaction. RESULTS: 100%, 90.2%, and 89.0% of patients achieved binocular UDVA, UNVA, and UIVA of logMAR 0.1 or better at 6 months postoperatively. 97.6% of eyes were within ± 1.00 D of emmetropia postoperatively. Optical quality assessments showed increases in modulation transfer function and Strehl ratios (p < 0.05). High-order aberrations decreased significantly (p < 0.05). Despite the high incidence of posterior capsule opacification (83.2%), managed with early Nd: YAG capsulotomy, no other severe complications were reported. Patient-reported outcomes indicated high satisfaction, with an average VF-14 score of 94.3 ± 10.2 and 93.5% achieving complete spectacle independence. Halo (66.2%) was the most commonly reported optical phenomena, followed by glare (18.2%), and starburst (7.8%) after surgery. CONCLUSIONS: Bilateral RLE with trifocal IOLs in presbyopic patients without cataracts significantly improves visual acuity and reduces ocular aberrations in presbyopic patients. The procedure offers high patient satisfaction and spectacle independence, though it requires careful patient selection and management of expectations regarding potential photic phenomena.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares Multifocales , Satisfacción del Paciente , Presbiopía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , China/epidemiología , Pueblos del Este de Asia , Implantación de Lentes Intraoculares/métodos , Presbiopía/cirugía , Presbiopía/fisiopatología , Refracción Ocular , Encuestas y Cuestionarios , Visión Binocular , Agudeza Visual
19.
Clin Optom (Auckl) ; 16: 157-167, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39050806

RESUMEN

Purpose: To explore links between subjective comfort and vision in habitual multifocal soft contact lens (MFCL) wearers when refit with daily disposable MFCLs, to determine which factors are relevant for success with MFCLs and evaluate consistency between MFCLs of different designs. Patients and Methods: This work examined subjective measures in a randomised, participant masked, bilateral wear crossover study at five optometry practices. Fifty-eight habitual MFCL wearers wore stenfilcon A multifocal (stenA-MF; CooperVision Inc) and delefilcon A multifocal (delA-MF; Alcon) for two-weeks. Subjective ratings included satisfaction with comfort and vision and agreement questions. Results: Agreement with "I would like to wear this MFCL in the future" was taken to indicate success with each MFCL; agreement was significantly higher with stenA-MF. There was strong correlation between agreement responses for "I would like to wear this MFCL in the future" and "MFCL met my needs for vision" with both lenses (p<0.01). However, it was only with stenA-MF, which had higher agreement responses to both statements (p<0.05), that responses to these two statements correlated with satisfaction with end-of-day (EOD) comfort (p<0.01). These differences in correlations between the two lenses are seemingly driven by greater satisfaction with stenA-MF for near and intermediate vision (p<0.05). Conclusion: Subjective vision and comfort were only correlated when vision met the needs of most participants. Meeting participants' needs for vision correlated strongly with wanting to wear a MFCL. Results indicate that meeting vision needs is more important than meeting comfort needs when influencing whether presbyopic patients continue wearing MFCLs.

20.
JPhys Photonics ; 6(3): 035021, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38975030

RESUMEN

Lens biomechanical properties are critical for our eyes to accommodate. While it is well understood that lens mechanical properties change with age, different experimental techniques have been used over the years, with varying results on how the lens modulus changes. In this study, we developed a spatial-varying elasticity model to characterize the overall elastic modulus of the lens and establish its effect on accommodation. First, to validate the model, ex vivo porcine lenses underwent compression testing using biopsy punches of different diameters to change the percentage of nucleus within samples. Importantly, we found that, indeed, changing nucleus/cortex spatial ratio produces dramatic (∼7-fold) increase in overall sample modulus. Comparing the model with human lens spatial ratios, we demonstrate how changing spatial mechanics are more influential than peak modulus changes on overall elastic modulus. Next, in vivo clinical measurements of the spatial-varying lens modulus were used to generate a simplified mechanical-optical model of accommodation. We defined an ellipsoid lens with patient-derived modulus and geometry measurements, and a statics simulation and ray tracing analysis were performed through the deformed and undeformed lens. The resulting accommodation estimates agree with general accommodation expectations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA