Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Anticancer Res ; 44(8): 3507-3514, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39060087

RESUMEN

BACKGROUND/AIM: Surgical resection with a minimally invasive approach is the standard for diagnosing and treating solitary pulmonary nodules. A computed tomography (CT)-guided technetium99m-macroaggregated albumin (99mTc-MAA) injection-based procedure has been employed for small and non-palpable lung nodule radio-guided preoperative localization (ROLL). This procedure is usually followed by video-assisted thoracoscopic surgery (VATS). This study retrospectively evaluated the feasibility, clinicopathologic outcomes, and complications of this localization radio-guided procedure followed by uniportal VATS. PATIENTS AND METHODS: This retrospective study included 63 patients with suspicious lung nodules who underwent 99mTc-MAA CT-guided localization before uniportal VATS. The analysis examined the imaging and procedure characteristics, procedural risks, successful intra-operative localization, wedge resection, conversion from VATS to open thoracotomy, the reason, and histological diagnosis for each nodule. Also, it was evaluated how nodule and procedure features affected successful intra-operative localization. RESULTS: All patients were diagnosed using a CT scan, and 90.4% had a PET scan at basal staging. A round-glass morphology was present in 9.6% of cases, whereas most had a solid appearance. The mean nodule size was 9.78 mm (maximal tumoral diameter) with a 1-23 mm range. The mean distance from the pleural surface was 15.6 mm (range=1-117 mm). The detection rate of the 99mTc-MAA CT-guided localization procedure was 100%. Surgical procedures were uniportal VATS and transpleural thoracoscopy in 52 (82.5%) and 11 (17.5%) patients, respectively. The intraoperative localization rate was 98.4%. Pneumothorax represented the most frequent complication (6.3%), with one case clinically significant and three only with minimal radiological evidence. Pathology confirmed radical excision in all cases. CONCLUSION: Lung nodule localization with CT-guided 99mTc-MAA followed by uniportal VATS is feasible with a high success rate and low complication rate.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Cirugía Torácica Asistida por Video , Tomografía Computarizada por Rayos X , Humanos , Cirugía Torácica Asistida por Video/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Neoplasias Pulmonares/cirugía , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Estudios Retrospectivos , Nódulo Pulmonar Solitario/cirugía , Nódulo Pulmonar Solitario/diagnóstico por imagen , Nódulo Pulmonar Solitario/patología , Tomografía Computarizada por Rayos X/métodos , Adulto , Radiofármacos/administración & dosificación , Anciano de 80 o más Años
2.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 43(2): 91-99, Mar-Abr. 2024. tab, graf, ilus
Artículo en Español | IBECS | ID: ibc-231818

RESUMEN

IntroducciónAnte el aumento constante de la demanda asistencial de exploraciones relacionadas con cirugía radioguiada (CRG), nuestro hospital adoptó incluir en el equipo de CRG nuevos perfiles profesionales con el fin de reducir parcialmente el tiempo de dedicación de los médicos nucleares a esta tarea.Objetivos: Analizar el proceso de incorporación de los perfiles de Técnico Superior en Imagen para el Diagnóstico (TSID) y Enfermera Referente de Ganglio Centinela (ERGC), evaluando su despliegue en los procedimientos ligados a la técnica. Material y métodos: Análisis de la actividad de CRG durante el periodo 2018-2022, centrándolo en los procedimientos prequirúrgicos y quirúrgicos relativos a cáncer de mama (CaM) y melanoma maligno (MM), por ser aquellas patologías en las que se concentró la transferencia de competencias asistenciales. Evolución cronológica de las competencias asumidas por los diferentes perfiles durante su integración en el equipo de CRG. Resultados: La actividad asistencial de CRG durante el periodo analizado experimentó un incremento del 109%. CaM y MM son las patologías que aglutinaron con diferencia una mayor demanda asistencial. La transferencia de competencias en estas dos patologías se ha producido de manera progresiva, asumiendo en 2022 el 74% (460/622) de la fase de administración el ERGC y el 64% (333/519) de las cirugías el TSID. Conclusiones: La creación de un equipo multidisciplinar de CRG, que incluye distintos perfiles profesionales (MN, ERGC y TSID), es una eficaz estrategia para dar respuesta al incremento de la complejidad y número de todos los procedimientos relacionados con la CRG.(AU)


Introduction: Given the constant increase in the healthcare demand for examinations related to radio-guided surgery (RGS), our hospital adopted new professional profiles in the RGS team, in order to partially reduce the time spent by nuclear medicine physicians on this task. Aim: To analyze the process of incorporating the profiles of Superior Diagnostic Imaging Technician (TSID) and Sentinel Node Referent Nurse (ERGC), evaluating their deployment in the procedures linked to the technique. Material and methods: Analysis of RGS activity during the period 2018-2022, focusing on pre-surgical and surgical procedures related to breast cancer (BC) and malignant melanoma (MM), as they are those pathologies on which the transfer of care competencies was concentrated. Chronological evolution of the competencies assumed by the different profiles during their integration into the RGS team. Results: RGS's healthcare activity during the analyzed period experienced an increase of 109%. BC and MM were the pathologies that accounted for by far the greatest demand for care. The transfer of competencies in these two pathologies occurred in a progressive and staggered manner, with 74% (460/622) of the administration phase being carried out by the ERGC and 64% (333/519) of the surgeries by the TSID in 2022. Conclusions: The creation of a multidisciplinary RGS team that includes different professional profiles (NM, ERGC and TSID) is an effective strategy to respond to the increase in the complexity and number of all procedures related to RGS.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Linfocintigrafia , Ganglio Linfático Centinela/diagnóstico por imagen , Biopsia del Ganglio Linfático Centinela , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Cirugía Asistida por Computador , Medicina Nuclear , Imagen Molecular , Estudios Retrospectivos
3.
Ann Surg Oncol ; 31(7): 4189-4196, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38652200

RESUMEN

BACKGROUND: Radio-guided surgery (RGS) holds promise for improving surgical outcomes in neuroendocrine tumors (NETs). Previous studies showed low specificity (SP) using γ-probes to detect radiation emitted by radio-labeled somatostatin analogs. OBJECTIVE: We aimed to assess the sensitivity (SE) and SP of the intraoperative RGS approach using a ß-probe with a per-lesion analysis, while assessing safety and feasibility as secondary objectives. METHODS: This prospective, single-arm, single-center, phase II trial (NCT05448157) enrolled 20 patients diagnosed with small intestine NETs (SI-NETs) with positive lesions detected at 68Ga-DOTA-TOC positron emission tomography/computed tomography (PET/CT). Patients received an intravenous injection of 1.1 MBq/Kg of 68Ga-DOTA-TOC 10 min prior to surgery. In vivo measurements were conducted using a ß-probe. Receiver operating characteristic (ROC) analysis was performed, with the tumor-to-background ratio (TBR) as the independent variable and pathology result (cancer vs. non-cancer) as the dependent variable. The area under the curve (AUC), optimal TBR, and absorbed dose for the surgery staff were reported. RESULTS: The intraoperative RGS approach was feasible in all cases without adverse effects. Of 134 specimens, the AUC was 0.928, with a TBR cut-off of 1.35 yielding 89.3% SE and 86.4% SP. The median absorbed dose for the surgery staff was 30 µSv (range 12-41 µSv). CONCLUSION: This study reports optimal accuracy in detecting lesions of SI-NETs using the intraoperative RGS approach with a novel ß-probe. The method was found to be safe, feasible, and easily reproducible in daily clinical practice, with minimal radiation exposure for the staff. RGS might potentially improve radical resection rates in SI-NETs. CLINICAL TRIALS REGISTRATION: 68Ga-DOTATOC Radio-Guided Surgery with ß-Probe in GEP-NET (RGS GEP-NET) [NCT0544815; https://classic. CLINICALTRIALS: gov/ct2/show/NCT05448157 ].


Asunto(s)
Neoplasias Intestinales , Intestino Delgado , Tumores Neuroendocrinos , Octreótido , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos , Cirugía Asistida por Computador , Humanos , Tumores Neuroendocrinos/cirugía , Tumores Neuroendocrinos/patología , Tumores Neuroendocrinos/diagnóstico por imagen , Femenino , Masculino , Estudios Prospectivos , Persona de Mediana Edad , Neoplasias Intestinales/cirugía , Neoplasias Intestinales/patología , Neoplasias Intestinales/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Anciano , Intestino Delgado/patología , Intestino Delgado/diagnóstico por imagen , Intestino Delgado/cirugía , Octreótido/análogos & derivados , Adulto , Cirugía Asistida por Computador/métodos , Compuestos Organometálicos , Somatostatina/análogos & derivados , Estudios de Seguimiento , Pronóstico , Partículas beta/uso terapéutico , Estudios de Factibilidad
4.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 43(1): 39-54, ene.- fev. 2024. ilus, tab
Artículo en Español | IBECS | ID: ibc-229453

RESUMEN

Desde sus inicios, la medicina nuclear se ha enfrentado a cambios tecnológicos que la han obligado a modificar sus modos operativos y a adecuar sus protocolos. En el campo de la cirugía radioguiada (CRG), la incorporación de la imagen gammagráfica preoperatoria y la detección intraoperatoria con la sonda gamma proporcionó un impulso definitivo a la biopsia del ganglio centinela (GC) para convertirse en el procedimiento estándar de aplicación en el melanoma y el cáncer de mama. Las diversas innovaciones tecnológicas y la adaptación consiguiente de protocolos confluyen en lo disruptivo y lo gradual. Como ejemplos evidentes tenemos la introducción de la tomografía por emisión de fotón único/tomografía computarizada (SPECT/TC) en el campo preoperatorio y las sondas Drop-in (Lightpoint Medical Ltd; Crystal photonics, Eurorad) en el intraoperatorio. Otros aspectos innovadores con posible aplicación en la CRG se basan en la utilización de la inteligencia artificial (IA), navegación y teleasistencia (AU)


Since its origins, nuclear medicine has faced technological changes that led to modifying operating modes and adapting protocols. In the field of radioguided surgery, the incorporation of preoperative scintigraphic imaging and intraoperative detection with the gamma probe provided a definitive boost to sentinel lymph node biopsy to become a standard procedure for melanoma and breast cancer. The various technological innovations and consequent adaptation of protocols come together in the coexistence of the disruptive and the gradual. As obvious examples we have the introduction of SPECT/CT in the preoperative field and Drop-in probes in the intraoperative field. Other innovative aspects with possible application in radio-guided surgery are based on the application of artificial intelligence, navigation and telecare (AU)


Asunto(s)
Humanos , Biopsia del Ganglio Linfático Centinela , Cirugía Asistida por Computador , Inteligencia Artificial , Hibridación Fluorescente in Situ
5.
Artículo en Inglés | MEDLINE | ID: mdl-38387785

RESUMEN

INTRODUCTION: Given the constant increase in the healthcare demand for examinations related to radio-guided surgery (RGS), our hospital adopted new professional profiles in the RGS team, in order to partially reduce the time spent by nuclear medicine physicians on this task. AIM: To analyze the process of incorporating the profiles of Diagnostic Imaging Technician (DIT) and Sentinel Node Referent Nurse (SNRN), evaluating their deployment in the procedures linked to the technique. MATERIAL AND METHODS: Analysis of RGS activity during the period 2018-2022, focusing on pre-surgical and surgical procedures related to breast cancer (BC) and malignant melanoma (MM), as they are those pathologies on which the transfer of care competencies was concentrated. Chronological evolution of the competencies assumed by the different profiles during their integration into the RGS team. RESULTS: RGS's healthcare activity during the analyzed period experienced an increase of 109%. BC and MM were the pathologies that accounted for by far the greatest demand for care. The transfer of competencies in these two pathologies occurred in a progressive and staggered manner, with 74% (460/622) of the administration phase being carried out by the SNRN and 64% (333/519) of the surgeries by the DIT in 2022. CONCLUSIONS: The creation of a multidisciplinary RGS team that includes different professional profiles (nuclear medicine physician [MN], ERGC and TSID) is an effective strategy to respond to the increase in the complexity and number of all procedures related to RGS.


Asunto(s)
Neoplasias de la Mama , Melanoma , Ganglio Linfático Centinela , Neoplasias Cutáneas , Cirugía Asistida por Computador , Humanos , Femenino , Biopsia del Ganglio Linfático Centinela/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/cirugía , Ganglio Linfático Centinela/patología , Melanoma/patología , Neoplasias Cutáneas/patología
6.
Artículo en Inglés | MEDLINE | ID: mdl-37963516

RESUMEN

Since its origins, nuclear medicine has faced technological changes that led to modifying operating modes and adapting protocols. In the field of radioguided surgery, the incorporation of preoperative scintigraphic imaging and intraoperative detection with the gamma probe provided a definitive boost to sentinel lymph node biopsy to become a standard procedure for melanoma and breast cancer. The various technological innovations and consequent adaptation of protocols come together in the coexistence of the disruptive and the gradual. As obvious examples we have the introduction of SPECT/CT in the preoperative field and Drop-in probes in the intraoperative field. Other innovative aspects with possible application in radio-guided surgery are based on the application of artificial intelligence, navigation and telecare.


Asunto(s)
Melanoma , Cirugía Asistida por Computador , Humanos , Inteligencia Artificial , Biopsia del Ganglio Linfático Centinela/métodos , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Cirugía Asistida por Computador/métodos
7.
Artículo en Inglés | MEDLINE | ID: mdl-37650931

RESUMEN

PURPOSE: The detection of small lung nodules in thoracoscopic procedure is difficult when the lesions are not located within the outer border of the lung. In the case of ground-glass opacities, it is often impossible to palpate the lesion. Marking lung nodules using a radiotracer is a known technique. We analysed the accuracy and safety of the technique and the potential benefits of operating in a hybrid operating room. METHODS: 57 patients, including 33 (58%) females with a median age of 67 years (range 21-82) were included. In 27 patients, we marked and resected the lesion in a hybrid room. In 30 patients, the lesion was marked at the department of radiology the day before resection. [99mTc]Tc-Macrosalb (Pulmocis®) was used at an activity of 1 MBq in the hybrid room and at an activity of 3 MBq the day before to get technical feasible results. Radioactivity was detected using the Neoprobe® detection system. RESULTS: Precise detection and resection of the nodules was possible in 95% of the lesions and in 93% of the patients. Complete thoracoscopic resection was possible in 90% of the patients. Total conversion rate was 10%, but conversion due to failure of the marking of the nodule was observed in only 5% of the patients. Histology revealed 28 (37%) primary lung cancers, 24 (32%) metastases and 21 (28%) benign lesions. In 13 (23%) patients, minor complications were observed. None of them required additional interventions. CONCLUSION: The radio-guided detection of small pulmonary nodules is very accurate and safe after CT-guided injection of [99mTc]Tc-Macrosalb. Performing the operation in a hybrid room has several logistic advantages and allows using lower technetium-99m activities. The technique allows minimally invasive lung sparing resection and prevents overtreatment of benign and metastatic lesions.

8.
Diagnostics (Basel) ; 13(16)2023 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-37627887

RESUMEN

BACKGROUND: Radio-guided surgery is a reliable approach used for localizing ground-glass opacities, lung nodules, and metastatic lymph nodes. Lung nodules, lymph node metastatic involvement, and ground-glass opacities often represent a challenge for surgical management and clinical work-up. METHODS: PubMed research was conducted from January 1997 to June 2023 using the keywords "radioguided surgery and lung cancer". RESULTS: Different studies were conducted with different tracers: technetium-99m-albumin macroaggregates, cyanoacrylate combined to technetium-99m-sulfur colloid, indium-111-pentetreotide, and fluorine-18-deoxyglucose. A study proposed naphthalocyanine radio-labeled with copper-64. Radio-guided surgery has been demonstrated to be a reliable approach in localizing a lesion, and has a low radiological burden for personnel exposure and low morbidity. The lack of necessity to conduct radio-guided surgery under fluoroscopy or echography makes this radio-guided surgery an easy way of performing precise surgical procedures. CONCLUSIONS: Radio-guided surgery is a feasible approach useful for the intraoperative localization of ground-glass opacities, lung nodules, and metastatic lymph nodes. It is a valid alternative to the existing approaches due to its low cost, associated low morbidity, the possibility to perform the procedure after several hours, the low radiation dose applied, and the small amount of time that is required to perform it.

9.
Diagnostics (Basel) ; 13(15)2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37568905

RESUMEN

Sentinel node biopsy (SNB) for prostate cancer (PCa) represents an innovative technique aimed at improving nodal staging accuracy. The routinary adoption of this procedure in patients undergoing radical prostatectomy (RP) might be crucial to identify candidates who could effectively benefit from extensive pelvic lymph nodal dissection (ePLND). Despite some promising results, SNB for PCa is still considered experimental due to the lack of solid evidence and procedural standardization. In this regard, our narrative review aimed to analyze the most recent literature in this field, providing an overview of both the diagnostic accuracy measures and the oncological outcomes of SNB.

10.
Cancers (Basel) ; 15(13)2023 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-37444438

RESUMEN

BACKGROUND: Intraoperative localisation of nodal disease in non-small cell lung cancer (NSCLC) can be challenging. Lymph node localisation via radiopharmaceuticals is used in many conditions; we tested the feasibility of this approach in NSCLC. METHODS: NSCLC patients were prospectively recruited. Intraoperative peri-tumoral injections of [99mTc]Tc-albumin nanocolloids were performed, followed by removing the tumour and locoregional lymph nodes. These were examined ex vivo with a gamma probe and labelled sentinel lymph nodes (SLNs) if they showed any activity or non-sentinel lymph nodes (nSLNs) if they did not. Thereafter, the surgical field was scanned with the probe; any further radioactive lymph node was removed and labelled as "extra" SLNs (eSLNs). All specimens were sent to histology, and metastatic status was recorded. RESULTS: 48 patients were enrolled, and 290 nodal stations were identified: 179 SLNs, 87 nSLNs, and 24 eSLNs. A total of 44 nodal metastases were identified in 22 patients, with 36 of them (82%) located within SLNs. Patients with nSLNs metastases had at least a co-existing positive SLN. No metastases were found in eSLNs. CONCLUSIONS: The technique shows high sensitivity for intraoperative nodal metastases identification. This information could allow selective lymphadenectomies in low-risk patients or more aggressive approaches in high-risk patients.

11.
J Nanobiotechnology ; 21(1): 155, 2023 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-37202750

RESUMEN

Surgical resection is the cornerstone of solid tumour treatment. Current techniques for evaluating margin statuses, such as frozen section, imprint cytology, and intraoperative ultrasound, are helpful. However, an intraoperative assessment of tumour margins that is accurate and safe is clinically necessary. Positive surgical margins (PSM) have a well-documented negative effect on treatment outcomes and survival. As a result, surgical tumour imaging methods are now a practical method for reducing PSM rates and improving the efficiency of debulking surgery. Because of their unique characteristics, nanoparticles can function as contrast agents in image-guided surgery. While most image-guided surgical applications utilizing nanotechnology are now in the preclinical stage, some are beginning to reach the clinical phase. Here, we list the various imaging techniques used in image-guided surgery, such as optical imaging, ultrasound, computed tomography, magnetic resonance imaging, nuclear medicine imaging, and the most current developments in the potential of nanotechnology to detect surgical malignancies. In the coming years, we will see the evolution of nanoparticles tailored to specific tumour types and the introduction of surgical equipment to improve resection accuracy. Although the promise of nanotechnology for producing exogenous molecular contrast agents has been clearly demonstrated, much work remains to be done to put it into practice.


Asunto(s)
Neoplasias , Cirugía Asistida por Computador , Humanos , Medios de Contraste , Neoplasias/diagnóstico por imagen , Neoplasias/cirugía , Cirugía Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen Óptica
12.
Phys Med ; 108: 102545, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37021607

RESUMEN

Radio-Guided Surgery (RGS) is a nuclear medicine technique to support the surgeon during surgery towards a complete tumor resection. It is based on intraoperative detection of radiation emitted by a radio-pharmaceutical that bounds selectively to tumoral cells. In the past years, an approach that exploits ß- emitting radiotracers has been pursued to overtake some limitations of the traditional RGS based on γ emission. A particle detector dedicated to this application, demonstrating very high efficiency to ß- particles and remarkable transparency to photons, has been thus developed. As a by-product, its characteristics suggested the possibility to utilize it with ß+ emitting sources, more commonly in use in nuclear medicine. In this paper, performances of such detector on 18F liquid sources are estimated by means of Monte Carlo simulations (MC) and laboratory measurements. The experimental setup with a 18F saline solution comprised a "positron signal" spot (a 7 × 10 mm cylinder representing the tumor residual), and a surrounding "far background" volume, that represented for the detector an almost isotropic source of annihilation photons. Experimental results show good agreement with MC predictions, thus confirming the expected performances of the detector with 18F, and the validity of the developed MC simulation as a tool to predict the gamma background determined by a diffuse source of annihilation photons.


Asunto(s)
Neoplasias , Cirugía Asistida por Computador , Humanos , Partículas beta , Simulación por Computador , Método de Montecarlo , Fotones , Tomografía de Emisión de Positrones/métodos
13.
Biomedicines ; 11(2)2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36831181

RESUMEN

OBJECTIVE: to evaluate the feasibility of the intra-operative application of a specimen PET/CT imager in a clinical setting. MATERIALS AND METHODS: this is a pilot analysis performed in three patients who received an intra-operative administration of 68Ga-PSMA-11 (n = 2) and 68Ga-DOTA-TOC (n = 1), respectively. Patients were administrated with PET radiopharmaceuticals to perform radio-guided surgery with a beta-probe detector during radical prostatectomy for prostate cancer (PCa) and salvage lymphadenectomy for recurrent neuroendocrine tumor (NET) of the ileum, respectively. All procedures have been performed within two ongoing clinical trials in our Institute (NCT05596851 and NCT05448157). Pathologic assessment with immunohistochemistry (PSMA-staining and SSA immunoreactivity) was considered as standard of truth. Specimen images were compared with baseline PET/CT images and histopathological analysis. RESULTS: Patients received 1 MBq/Kg of 68Ga-PSMA-11 (PCa) or 1.2 MBq/Kg of 68Ga-DOTA-TOC (NET) prior to surgery. Specimens were collected, positioned in the dedicated specimen container, and scanned to obtain high-resolution PET/CT images. In all cases, a perfect match was observed between the findings detected by the specimen imager and histopathology. Overall, the PET spatial resolution was sensibly higher for the specimen images compared to the baseline whole-body PET/CT images. Furthermore, the use of the PET/CT specimen imager did not significantly interfere with any procedures, and the overall length of the surgery was not affected using the PET/CT specimen imager. Finally, the radiation exposure of the operating theater staff was lower than 40 µSv per procedure (range 26-40 µSv). CONCLUSIONS: the image acquisition of specimens obtained by patients who received intra-surgery injections of 68Ga-PSMA-11 and 68Ga-DOTA-TOC was feasible and reliable also in a live-experience session and has been easily adapted to surgery daily practice. The high sensitivity, together with the evaluation of intra-lesion tumor heterogeneity, were the most relevant results since the data derived from specimen PET/CT imaging matched perfectly with the histopathological analysis.

14.
Front Med (Lausanne) ; 9: 931867, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36117970

RESUMEN

Objectives: To determine the accuracy of nodal staging in patients with prostate cancer (PCa) when 99 m Tc-nanocolloid radiotracer is injected into an index lesion (IL). Methods: This prospective study was conducted at our institution between June 2016 and October 2020. It included 64 patients with localized PCa with at least a 5% possibility for lymph node involvement in the Memorial Sloan Kettering Cancer Center nomogram, suitable for surgical treatment. All patients underwent magnetic resonance imaging (MRI) with IL and were pathologically confirmed. The day before surgery, transrectal ultrasound-guided injection (TRUS) of 99 m Tc-nanocolloid into the IL was performed. Surgical procedures included radical prostatectomy (RP), sentinel lymph node biopsy (SLNB), and extended pelvic lymphadenectomy (ePLND). Analysis was performed, including histopathological findings of RP, ePLND, and SLNB. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), false negative (FN), false positive (FP), diagnostic yield, and non-diagnostic rate were calculated. Results: A total of 1,316 lymph nodes were excised, including 1,102 from the ePLND (83.7%) and 214 (16.3%) sentinel lymph nodes (SLN). 26 SLN were dissected outside the ePLND template. The final pathology demonstrated 46 (3.5%) lymph node metastasis, 31 (67.4%) in the SLNB and 15 (32.6%) in the non-SLN ePLND. At the patient level, 18 (28.1%) patients had pN1. With a mean follow-up of 33.1 months, 4/19 (21.1%) pN1 patients had undetectable PSA, and 3/19 (15.8%) had a PSA < 0.1 ng/mL. Lymph node dissection included 20.6 lymph nodes per patient (IQR 15-24.2), with 3.3 SLNB nodes per patient (IQR 2-4.2). PPV and NPV were 100 and 97.8%, respectively. Sensitivity and specificity were 94.4 and 100%, respectively. FN was 5.5% and FP was 4.3%. Diagnostic yields were 95.3% and the non-diagnostic rate was 4.7%. Conclusion: Radiotracer injection into the prostate IL offers promising results for staging purposes in cases in which ePLND is considered. Negative SLNB is a predictor of negative ePLND. Patients with a limited burden of nodal metastasis have a significant chance of remaining free of biochemical recurrence at mid-term follow-up.

15.
Cancers (Basel) ; 14(9)2022 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-35565350

RESUMEN

18F-fluorodeoxyglucose (FDG) is a glucose analog that acts as a marker for glucose uptake and metabolism. FDG PET scans are used in monitoring pediatric cancers. The handheld PET probe localization of FDG-avid lesions is an emerging modality for radio-guided surgery (RGS). We sought to assess the utility of PET probe in localizing occult FDG-avid tumors in pediatric patients. PET probe functionality was evaluated by using a PET/CT scan calibration phantom. The PET probe was able to detect FDG photon emission from simulated tumors with an expected decay of the radioisotope over time. Specificity for simulated tumor detection was lower in a model that included background FDG. In a clinical model, eight pediatric patients with FDG-avid primary, recurrent or metastatic cancer underwent a tumor excision, utilizing IV FDG and PET probe survey. Adequate tissue for diagnosis was present in 16 of 17 resected specimens, and pathology was positive for malignancy in 12 of the 17 FDG-avid lesions. PET probe gamma counts per second were higher in tumors compared with adjacent benign tissue in all operations. The median ex vivo tumor-to-background ratio (TBR) was 4.0 (range 0.9-12). The PET probe confirmed the excision of occult FDG-avid tumors in eight pediatric patients.

16.
Curr Radiopharm ; 15(1): 32-39, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33397277

RESUMEN

BACKGROUND: Nimotuzumab is a humanized anti-epidermal growth factor receptor (EGFR) monoclonal antibody, nowadays used for tumour immunochemotherapy. This study aimed to label the conjugate DOTA-nimotuzumab with yttrium-90, in order to provide a ß- emitting radioimmunoconjugate (90Y-DOTA-nimotuzumab) potentially useful to assess the feasibility of a new radio-guided surgery approach. METHODS: The synthesis of 90Y-DOTA-nimotuzumab was performed in two days. Nimotuzumab was conjugated with a 50-fold excess of DOTA and then labelled with 90Y3+. The 90Y-DOTA-nimotuzumab preparation was optimized considering several parameters such as pH, temperature and reaction volume. Moreover, the 90Y-DOTA-nimotuzumab stability was evaluated in human plasma. RESULTS: The radioimmunoconjugate 90Y-DOTA-nimotuzumab was obtained with a radiochemical purity greater than 96%, and showed a good stability at 20°C as well as at 37°C in human plasma. CONCLUSIONS: The optimized conditions for a mild and easy preparation of 90Y-DOTA-nimotuzumab joined to a promising stability under physiological conditions suggest to propose this radioimmunoconjugate as a potential diagnostic radiopharmaceutical for ß- radio-guided surgery.


Asunto(s)
Antineoplásicos , Inmunoconjugados , Anticuerpos Monoclonales , Anticuerpos Monoclonales Humanizados , Compuestos Heterocíclicos , Humanos , Inmunoconjugados/farmacología , Compuestos Organometálicos , Radiofármacos/farmacología , Radioisótopos de Itrio/uso terapéutico
17.
Eur J Nucl Med Mol Imaging ; 49(5): 1743-1753, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34748059

RESUMEN

INTRODUCTION: Previous studies indicated that location and amount of detected sentinel lymph nodes (SLNs) in prostate cancer (PCa) are influenced where SLN-tracer is deposited within the prostate. To validate whether intratumoral (IT) tracer injection helps to increase identification of tumor-positive lymph nodes (LNs) better than intraprostatic (IP) tracer injection, a prospective randomized phase II trial was performed. METHODS: PCa patients with a > 5% risk of lymphatic involvement were randomized between ultrasound-guided transrectal injection of indocyanine green-[99mTc]Tc-nanocolloid in 2 depots of 1 mL in the tumor (n = 55, IT-group) or in 4 depots of 0.5 mL in the peripheral zone of the prostate (n = 58, IP-group). Preoperative lymphoscintigraphy and SPECT/CT were used to define the location of the SLNs. SLNs were dissected using combination of radio- and fluorescence-guidance, followed by extended pelvic LN dissection and robot-assisted radical prostatectomy. Outcome measurements were number of tumor-bearing SNs, tumor-bearing LNs, removed nodes, number of patients with nodal metastases, and metastasis-free survival (MFS) of 4-7-year follow-up data. RESULTS: IT-injection did not result in significant difference of removed SLNs (5.0 vs 6.0, p = 0.317) and histologically positive SLNs (28 vs 22, p = 0.571). However, in IT-group, the SLN-positive nodes were 73.7% of total positive nodes compared to 37.3% in IP-group (p = 0.015). Moreover, significantly more node-positive patients were found in IT-group (42% vs 24%, p = 0.045), which did not result in worse MFS. In two patients (3.6%) from whom the IT-tracer injection only partly covered intraprostatic tumor spread, nodal metastases in ePLND without tumor-positive SNs were yielded. CONCLUSIONS: The percentage-positive SLNs found after IT-injection were significantly higher compared to IP-injection. Significantly more node-positive patients were found using IT-injection, which did not affect MFS. IT-injection failed to detect nodal metastases from non-index satellite lesions. Therefore, we suggest to combine IT- and IP-tracer injections in men with visible tumor on imaging.


Asunto(s)
Neoplasias de la Próstata , Ganglio Linfático Centinela , Drenaje , Humanos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Masculino , Estudios Prospectivos , Neoplasias de la Próstata/patología , Ganglio Linfático Centinela/patología , Biopsia del Ganglio Linfático Centinela/métodos
18.
EJNMMI Res ; 11(1): 22, 2021 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-33661414

RESUMEN

PURPOSE: Intraoperative identification of prostate cancer (PCa) lymph node (LN) metastases (LNM) detected by preoperative PSMA PET/CT may be facilitated by PSMA radio-guided surgery (RGS) with use of a γ-probe. Earlier we demonstrated excellent performance of the 111In-labelled PSMA ligand DKFZ-617 ([111In]In-PSMA-617) in RGS for ex situ distinction of LN vs LNM at lymphadenectomy (LA) at a single LN level. In comparison with indium-111, technetium-99m has better physical properties for γ-probe measurements, better availability and lower radiation exposure for patients and medical personnel. Against this background, we evaluated the uptake of 99mTc-PSMA-I&S ligand at the level of single LN and its power to discriminate between unaffected LN and LNM. METHODS: Six patients with PCa with the suspicion of LNM on preoperative PSMA-PET/CT underwent [99mTc]Tc-PSMA-I&S RGS (4 salvage LA, 2 primary LA) with intravenous injection of [99mTc]Tc-PSMA-I&S 24 h prior to surgery. Resected samples were isolated manually aiming at the level of single LN. Uptake measurements were done ex situ with a high-purity germanium detector. Receiver operating characteristic (ROC) analysis was performed based on [99mTc]Tc-PSMA-I&S uptake expressed as lean body mass standard uptake value (SUL). RESULTS: Separation of the tissue samples from 73 subregions resulted in 498 single samples. After final histopathology 356 LN, 160 LNM und 11 non-nodal PCa samples were identified. Median SUL of tumor-free samples (0.26) and samples with cancer (3.5) was significantly different (p < 0.0001). ROC analysis revealed an area under the curve (AUC) of 0.917 (95% CI 0.89-0.95). Using a SUL cutoff of 1.1, sensitivity, specificity, positive predictive value, and negative predictive values were 76.6%, 94.4%, 89.4% and 86.9%. CONCLUSION: Ex situ analysis of [99mTc]Tc-PSMA-I&S uptake at single LN level showed good diagnostic performance for the ex situ distinction of tumor-bearing vs tumor-free LN during RGS.

19.
Curr Radiopharm ; 14(2): 161-169, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32693772

RESUMEN

BACKGROUND: Radioguided surgery represents a validated technique for the detection and the excision of abnormal parathyroid glands responsible for primary hyperparathyroidism (PHPT). To date little attention has been paid as to how the characteristics of gamma-probes can influence surgical procedure and time, thus having an impact on postoperative morbidity, hospitalization and costs. METHODS: We designed a new prototype of gamma-probe, the Gonioprobe, and tested its clinical utility in the operating room. Gonioprobe, thanks to its 5 scintillating independent crystals, performs the dual function of Navigator and Lock-on-target. These characteristics allow the immediate guidance of the surgeon's hand towards the source with very high precision, and with a much higher spatial resolution than commercial probes. Gonioprobe was used during intervention to detect abnormal parathyroid tissue, and to ensure no radioactivity in surgery bed after adenoma removal. RESULTS: We tested our gamma-probe on parathyroid adenomas particularly difficult to identify at a visual inspection due to anatomy modifications from previous neck surgery and/or characterized by uncommon localization. Moreover, parathyroid adenomas were hardly removable due to the proximity to the esophagus, neck vessels and/or recurrent laryngeal nerve (RLN). An intraoperative nerve monitoring system was used to protect the recurrent laryngeal nerve from injuries. Parathyroid hormone (PTH) assay and frozen biopsy confirmed the successful excision of the adenomas. CONCLUSION: The intraoperative use of the innovative Gonioprobe along with the nerve monitoring system allowed an accurate and safe removal of parathyroid adenomas and offered a significant advantage by reducing surgical time and postoperative complications, as well as hospitalization and costs.


Asunto(s)
Hiperparatiroidismo Primario/cirugía , Neoplasias de las Paratiroides/cirugía , Paratiroidectomía/métodos , Cirugía Asistida por Computador/métodos , Adulto , Anciano , Biopsia , Costos y Análisis de Costo , Femenino , Cámaras gamma , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias , Cintigrafía , Radiofármacos , Traumatismos del Nervio Laríngeo Recurrente/prevención & control , Tecnecio Tc 99m Sestamibi , Tomografía Computarizada de Emisión de Fotón Único
20.
EJNMMI Res ; 10(1): 17, 2020 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-32144598

RESUMEN

PURPOSE: Identification of suspicious PSMA-PET/CT-positive lymph node (LN) metastases (LNM) from prostate cancer (PCa) during lymphadenectomy (LA) is challenging. We evaluated an 111In-labelled PSMA ligand (DKFZ-617, referred to as [111In]PSMA-617) as a γ-emitting tracer for intraoperative γ-probe application for resected tissue samples in PCa patients. Forty-eight hours prior to LA, [111In]PSMA-617 was administered intravenously in 23 patients with suspected LNM on PSMA-PET/CT (n = 21 with biochemical relapse, n = 2 at primary therapy). Resected tissue samples (LN, LNM and fibrofatty tissue) were measured ex situ by a γ-probe expressed as counts per second (CPSnorm). [111In]PSMA-617 tissue sample uptake was measured by a germanium detector for verification and calculated as %IAlbm (percent injected activity per kilogram lean body mass at time of surgery). Based on a clinical requirement for a specificity > 95%, thresholds for both ex situ measurements were chosen accordingly. Correlation of the results from PET/CT, γ-probe and germanium detector with histopathology was done. RESULTS: Eight hundred sixty-four LNs (197 LNM) were removed from 275 subregions in 23 patients, on average 8.6 ± 14.9 LNM per patient. One hundred four of 275 tissue samples showed cancer. Median γ-probe and germanium detector results were significantly different between tumour-affected (33.5 CPSnorm, 0.71 %IAlbm) and tumour-free subregions (3.0 CPSnorm, 0.03 %IAlbm) (each p value < 0.0001). For the chosen γ-probe cut-off (CPSnorm > 23) and germanium detector cut-off (%IAlbm > 0.27), 64 and 74 true-positive and 158 true-negative samples for both measurements were identified. Thirty-nine and 30 false-negative and 6 and 5 false-positive tissue samples were identified by γ-probe and germanium detector measurements. CONCLUSION: [111In]PSMA-617 application for LA is feasible in terms of an intraoperative real-time measurement with a γ-probe for detection of tumour-affected tissue samples. γ-probe results can be confirmed by precise germanium detector measurements and were significantly different between tumour-affected and tumour-free samples.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA