Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 689
Filtrar
1.
Adv Healthc Mater ; : e2401704, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39011795

RESUMEN

A bio-hydrogel is prepared via a low-cost and time-saving strategy and is studied as a self-powered wound dressing for precision medicine and health monitoring. Promoted by a dual self-catalytic pair composed of Fe3+ and catechol, gelation time is dramatically accelerated to 15 s and the hydrogel can be freely modeled at -18 °C without losing flexibility. As smart wound dressing, the required properties such as self-healing, self-adhesion, antibacterial, and sensing stability, are integrated into one hydrogel. TA@CNC offers abundant hydrogen bond and metal-ligand coordination which facilitate the hydrogel with a self-healing efficiency of 91.6%. Owing to the catechol in TA@CNC, hydrogel can adhere to multiple substrates including skin, and show good antibacterial activity. Inspired by a fruit battery, a self-powered wound dressing is fabricated, which exhibits excellent correlation and efficiency in real-time monitoring of body activity and drug release. In vivo experiments prove that efficient drug release of hydrogel dressing significantly accelerate wound healing. Additionally, the dressing exhibits excellent biocompatibility and has no negative impacts on organs. Herein, a smart wound dressing that is different from the traditional way is proposed. As a self-powered device, it can be integrated with wireless devices and is expected to participate in promising applications.

2.
Polymers (Basel) ; 16(13)2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-39000697

RESUMEN

The latest progress (the year 2021-2024) on multifunctional sensors based on silicone rubber is reported. These multifunctional sensors are useful for real-time monitoring through relative resistance, relative current change, and relative capacitance types. The present review contains a brief overview and literature survey on the sensors and their multifunctionalities. This contains an introduction to the different functionalities of these sensors. Following the introduction, the survey on the types of filler or rubber and their fabrication are briefly described. The coming section deals with the fabrication methodology of these composites where the sensors are integrated. The special focus on mechanical and electro-mechanical properties is discussed. Electro-mechanical properties with a special focus on response time, linearity, and gauge factor are reported. The next section of this review reports the filler dispersion and its role in influencing the properties and applications of these sensors. Finally, various types of sensors are briefly reported. These sensors are useful for monitoring human body motions, breathing activity, environment or breathing humidity, organic gas sensing, and, finally, smart textiles. Ultimately, the study summarizes the key takeaway from this review article. These conclusions are focused on the merits and demerits of the sensors and are followed by their future prospects.

3.
Methods Mol Biol ; 2833: 109-119, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38949705

RESUMEN

Tuberculosis (TB) is the most common cause of death from an infectious disease. Although treatment has been available for more than 70 years, it still takes too long and many patients default risking relapse and the emergence of resistance. It is known that lipid-rich, phenotypically antibiotic-tolerant, bacteria are more resistant to antibiotics and may be responsible for relapse necessitating extended therapy. Using a microfluidic system that acoustically traps live mycobacteria, M. smegmatis, a model organism for M. tuberculosis we can perform optical analysis in the form of wavelength-modulated Raman spectroscopy (WMRS) on the trapped organisms. This system can allow observations of the mycobacteria for up to 8 h. By adding antibiotics, it is possible to study the effect of antibiotics in real-time by comparing the Raman fingerprints in comparison to the unstressed condition. This microfluidic platform may be used to study any microorganism and to dynamically monitor its response to many conditions including antibiotic stress, and changes in the growth media. This opens the possibility of understanding better the stimuli that trigger the lipid-rich downregulated and phenotypically antibiotic-resistant cell state.


Asunto(s)
Mycobacterium smegmatis , Espectrometría Raman , Espectrometría Raman/métodos , Mycobacterium smegmatis/efectos de los fármacos , Mycobacterium smegmatis/crecimiento & desarrollo , Microfluídica/métodos , Microfluídica/instrumentación , Antibacterianos/farmacología , Acústica/instrumentación , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Humanos
4.
Fundam Res ; 4(3): 442-454, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38933213

RESUMEN

The aerosol transmission of coronavirus disease in 2019, along with the spread of other respiratory diseases, caused significant loss of life and property; it impressed upon us the importance of real-time bioaerosol detection. The complexity, diversity, and large spatiotemporal variability of bioaerosols and their external/internal mixing with abiotic components pose challenges for effective online bioaerosol monitoring. Traditional methods focus on directly capturing bioaerosols before subsequent time-consuming laboratory analysis such as culture-based methods, preventing the high-resolution time-based characteristics necessary for an online approach. Through a comprehensive literature assessment, this review highlights and discusses the most commonly used real-time bioaerosol monitoring techniques and the associated commercially available monitors. Methods applied in online bioaerosol monitoring, including adenosine triphosphate bioluminescence, laser/light-induced fluorescence spectroscopy, Raman spectroscopy, and bioaerosol mass spectrometry are summarized. The working principles, characteristics, sensitivities, and efficiencies of these real-time detection methods are compared to understand their responses to known particle types and to contrast their differences. Approaches developed to analyze the substantial data sets obtained by these instruments and to overcome the limitations of current real-time bioaerosol monitoring technologies are also introduced. Finally, an outlook is proposed for future instrumentation indicating a need for highly revolutionized bioaerosol detection technologies.

5.
J Nanobiotechnology ; 22(1): 374, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926723

RESUMEN

BACKGROUND: Hypoxia-activated prodrugs present new opportunities for safe and effective tumor drug resistance therapy due to their high selectivity for hypoxic cells. However, the uneven distribution of oxygen in solid tumor and insufficient hypoxia in the tumor microenvironment greatly limit its therapeutic efficacy. RESULTS: In this paper, a novel AQ4N-Mn(II)@PDA coordination nanoplatform was designed and functionalized with GMBP1 to target drug-resistant tumor cells. Its excellent photothermal conversion efficiency could achieve local high-temperature photothermal therapy in tumors, which could not only effectively exacerbate tumor hypoxia and thus improve the efficacy of hypoxia-activated chemotherapy of AQ4N but also significantly accelerate Mn2+-mediated Fenton-like activity to enhance chemodynamic therapy. Moreover, real-time monitoring of blood oxygen saturation through photoacoustic imaging could reflect the hypoxic status of tumors during treatment. Furthermore, synergistic treatment effectively inhibited tumor growth and improved the survival rate of mice bearing orthotopic drug-resistant tumors. CONCLUSIONS: This study not only provided a new idea for PTT combined with hypoxia-activated chemotherapy and CDT for drug-resistant tumors but also explored a vital theory for real-time monitoring of hypoxia during treatment.


Asunto(s)
Resistencia a Antineoplásicos , Terapia Fototérmica , Animales , Ratones , Resistencia a Antineoplásicos/efectos de los fármacos , Línea Celular Tumoral , Humanos , Terapia Fototérmica/métodos , Ratones Endogámicos BALB C , Nanopartículas/química , Antineoplásicos/farmacología , Antineoplásicos/química , Microambiente Tumoral/efectos de los fármacos , Ratones Desnudos , Profármacos/farmacología , Profármacos/química , Hipoxia Tumoral/efectos de los fármacos , Manganeso/química , Femenino , Neoplasias/tratamiento farmacológico , Antraquinonas
6.
Photoacoustics ; 38: 100622, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38911132

RESUMEN

Microwave ablation (MWA) is a potent cancer treatment tool, but its effectiveness can be hindered by the lack of visual feedback. This paper validates the feasibility of using microwave-induced thermoacoustic imaging (TAI) technique to monitor the MWA process. A feasibility analysis was conducted at the principle level and a high-performance real-time TAI system was introduced. To address the interference caused by MWA, a robust principal component analysis (RPCA)-based method for TAI was proposed. This method leverages the correlation between multiple signal frames to eliminate interference. RPCA's effectiveness in TAI was demonstrated through three sets of different experiments. Experiments demonstrated that TAI can effectively monitors the MWA process. This work represents the first application of RPCA-related matrix decomposition methods in TAI, paving the way for the application of TAI in more complex clinical scenarios. By providing rapid and accurate visual feedback, this research advances MWA technology.

7.
Sci Total Environ ; 943: 173649, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38852865

RESUMEN

This research builds upon a previous study that explored the potential of the modified WIBS-4+ to selectively differentiate and detect different bioaerosol classes. The current work evaluates the influence of meteorological and air quality parameters on bioaerosol concentrations, specifically pollen and fungal spore dynamics. Temperature was found to be the most influential parameter in terms of pollen production and release, showing a strong positive correlation. Wind data analysis provided insights into the potential geographic origins of pollen and fungal spore concentrations. Fungal spores were primarily shown to originate from a westerly direction, corresponding to agricultural land use, whereas pollen largely originated from a North-easterly direction, corresponding to several forests. The influence of air quality was also analysed to understand its potential impact on the WIBS fluorescent parameters investigated. Most parameters had a negative association with fungal spore concentrations, whereas several anthropogenic influences showed notable positive correlations with daily pollen concentrations. This is attributed to similar driving forces (meteorological parameters) and geographical origins. In addition, the WIBS showed a significant correlation with anthropogenic pollutants originating from combustion sources, suggesting the potential for such modified spectroscopic instruments to be utilized as air quality monitors. By combining all meteorological and pollution data along with WIBS-4+ channel data, a set of Multiple Linear Regression (MLR) analyses were completed. Successful results with R2 values ranging from 0.6 to 0.8 were recorded. The inclusion of meteorological parameters was dependent on the spore or pollen type being examined.


Asunto(s)
Aerosoles , Contaminantes Atmosféricos , Monitoreo del Ambiente , Polen , Esporas Fúngicas , Monitoreo del Ambiente/métodos , Aerosoles/análisis , Contaminantes Atmosféricos/análisis , Contaminación del Aire/estadística & datos numéricos , Microbiología del Aire , Viento , Análisis Espectral/métodos
8.
J Chromatogr A ; 1729: 465013, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-38824753

RESUMEN

The application of Process Analytical Technology (PAT) principles for manufacturing of biotherapeutics proffers the prospect of ensuring consistent product quality along with increased productivity as well as substantial cost and time savings. Although this paradigm shift from a traditional, rather rigid manufacturing model to a more scientific, risk-based approach has been advocated by health authorities for almost two decades, the practical implementation of PAT in the biopharmaceutical industry is still limited by the lack of fit-for-purpose analytical methods. In this regard, most of the proposed spectroscopic techniques are sufficiently fast but exhibit deficiencies in terms of selectivity and sensitivity, while well-established offline methods, such as (ultra-)high-performance liquid chromatography, are generally considered as too slow for this task. To address these reservations, we introduce here a novel online Liquid Chromatography (LC) setup that was specifically designed to enable real-time monitoring of critical product quality attributes during time-sensitive purification operations in downstream processing. Using this online LC solution in combination with fast, purpose-built analytical methods, sampling cycle times between 1.30 and 2.35 min were achieved, without compromising on the ability to resolve and quantify the product variants of interest. The capabilities of our approach are ultimately assessed in three case studies, involving various biotherapeutic modalities, downstream processes and analytical chromatographic separation modes. Altogether, our results highlight the expansive opportunities of online LC based applications to serve as a PAT tool for biopharmaceutical manufacturing.


Asunto(s)
Productos Biológicos , Productos Biológicos/análisis , Productos Biológicos/química , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/química
9.
Talanta ; 277: 126399, 2024 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-38876030

RESUMEN

The misregulation of protein phosphatases is a key factor in the development of many human diseases, notably cancers. Here, based on a 100 MHz quartz crystal microbalance (QCM) biosensing platform, the dephosphorylation process of phosphopeptide (P-peptide) caused by protein tyrosine phosphatase 1B (PTP1B) was monitored in real time for the first time and PTP1B activity was assayed rapidly and sensitively. The QCM chip, coated with a gold (Au) film, was used to immobilized thiol-labeled single-stranded 5'-phosphate-DNAs (P-DNA) through Au-S bond. The P-peptide, specific to PTP1B, was then connected to the P-DNA via chelation between Zr4+ and phosphate groups. When PTP1B was injected into the QCM flow cell where the P-peptide/Zr4+/MCH/P-DNA/Au chip was placed, the P-peptide was dephosphorylated and released from the Au chip surface, resulting in an increase in the frequency of the QCM Au chip. This allowed the real-time monitoring of the P-peptide dephosphorylation process and sensitive detection of PTP1B activity within 6 min with a linear detection range of 0.01-100 pM and a detection limit of 0.008 pM. In addition, the maximum inhibitory ratios of inhibitors were evaluated using this proposed 100 MHz QCM biosensor. The developed 100 MHz QCM biosensing platform shows immense potential for early diagnosis of diseases related to protein phosphatases and the development of drugs targeting protein phosphatases.

10.
Water Sci Technol ; 89(11): 2894-2906, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38877620

RESUMEN

With the impact of global climate change and the urbanization process, the risk of urban flooding has increased rapidly, especially in developing countries. Real-time monitoring and prediction of flooding extent and drainage system are the foundation of effective urban flood emergency management. Therefore, this paper presents a rapid nowcasting prediction method of urban flooding based on data-driven and real-time monitoring. The proposed method firstly adopts a small number of monitoring points to deduce the urban global real-time water level based on a machine learning algorithm. Then, a data-driven method is developed to achieve dynamic urban flooding nowcasting prediction with real-time monitoring data and high-accuracy precipitation prediction. The results show that the average MAE and RMSE of the urban flooding and conduit system in the deduction method for water level are 0.101 and 0.144, 0.124 and 0.162, respectively, while the flooding depth deduction is more stable compared to the conduit system by probabilistic statistical analysis. Moreover, the urban flooding nowcasting method can accurately predict the flooding depth, and the R2 are as high as 0.973 and 0.962 of testing. The urban flooding nowcasting prediction method provides technical support for emergency flood risk management.


Asunto(s)
Inundaciones , Monitoreo del Ambiente/métodos , Ciudades , Modelos Teóricos , Cambio Climático
11.
Sensors (Basel) ; 24(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38894109

RESUMEN

The adoption of the Internet of Things (IoT) in the mining industry can dramatically enhance the safety of workers while simultaneously decreasing monitoring costs. By implementing an IoT solution consisting of a number of interconnected smart devices and sensors, mining industries can improve response times during emergencies and also reduce the number of accidents, resulting in an overall improvement of the social image of mines. Thus, in this paper, a robust end-to-end IoT system for supporting workers in harsh environments such as in mining industries is presented. The full IoT solution includes both edge devices worn by the workers in the field and a remote cloud IoT platform, which is responsible for storing and efficiently sharing the gathered data in accordance with regulations, ethics, and GDPR rules. Extended experiments conducted to validate the IoT components both in the laboratory and in the field proved the effectiveness of the proposed solution in monitoring the real-time status of workers in mines.

12.
Sensors (Basel) ; 24(11)2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38894265

RESUMEN

This paper introduces SEISMONOISY, an application designed for monitoring the spatiotemporal characteristic and variability of the seismic noise of an entire seismic network with a quasi-real-time monitoring approach. Actually, we have applied the developed system to monitor 12 seismic networks distributed throughout the Italian territory. These networks include the Rete Sismica Nazionale (RSN) as well as other regional networks with smaller coverage areas. Our noise monitoring system uses the methods of Spectral Power Density (PSD) and Probability Density Function (PDF) applied to 12 h long seismic traces in a 24 h cycle for each station, enabling the extrapolation of noise characteristics at seismic stations after a Seismic Noise Level Index (SNLI), which takes into account the global seismic noise model, is derived. The SNLI value can be used for different applications, including network performance evaluation, the identification of operational problems, site selection for new installations, and for scientific research applications (e.g., volcano monitoring, identification of active seismic sequences, etc.). Additionally, it aids in studying the main noise sources across different frequency bands and changes in the characteristics of background seismic noise over time.

13.
Anim Cells Syst (Seoul) ; 28(1): 315-325, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38895161

RESUMEN

Exposure to toxic molecules from food or oral medications induces toxicity in colon cells that cause various human diseases; however, in vitro monitoring systems for colon cell toxicity are not well established. Stress granules are nonmembranous foci that form in cells exposed to cellular stress. When cells sense toxic environments, they acutely and systemically promote stress granule formation, with Ras GTPase-activating protein-binding protein 1 (G3BP1) acting as a core component to protect their mRNA from abnormal degradation. Here, we knocked in green fluorescent protein (GFP)-coding sequences into the C-terminal region of the G3BP1 gene in a human colon cell line through CRISPR-Cas9-mediated homologous recombination and confirmed the formation of stress granules with the G3BP1-GFP protein in these cells under cellular stress exposure. We demonstrated the formation and dissociation of stress granules in G3BP1-GFP expressing colon cells through real-time monitoring using a fluorescence microscope. Furthermore, we validated the toxicity monitoring system in the established colon cell line by observing stress granule formation following exposure to dihydrocapsaicin, bisphenol A, and sorbitol. Taken together, we established a stress granule reporter system in a colon cell line, providing a novel assessment for the real-time monitoring of colon toxicity in response to various chemicals.

14.
Food Chem ; 452: 139549, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38762939

RESUMEN

The prevention of pollution requires real-time monitoring of cadmium (Cd2+) concentration in the food, as it has a dramatic impact on poultry and can pose a threat to human health. Here, we fabricate a portable workstation integrating a microfluidic chip that facilitates real-time monitoring of Cd2+ levels in real samples by utilizing the Luminol-KMnO4 chemiluminescence (CL) system. Interestingly, Cd2+ can significantly enhance the CL signal, resulting in sensitive detection of Cd2+ in the range of 0-0.18 mg/L with the limit of detection (LOD) of 0.207 µg/L. Furthermore, a remote-controlled unit is integrated into the portable workstation to form a remote-controlled portable workstation (RCPW) performing automated point-of-care testing (POCT) of Cd2+. The as-prepared strategy allows remote control of RCPW to avoid long-distance transportation of samples to achieve real-time target monitoring. Consequently, this system furnishes RCPW for monitoring Cd2+ levels in real samples, thereby holding potential for applications in preventing food pollution.


Asunto(s)
Cadmio , Contaminación de Alimentos , Límite de Detección , Mediciones Luminiscentes , Cadmio/análisis , Contaminación de Alimentos/análisis , Mediciones Luminiscentes/instrumentación , Mediciones Luminiscentes/métodos , Animales , Luminiscencia , Pruebas en el Punto de Atención
15.
ACS Sens ; 9(6): 3262-3271, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38809959

RESUMEN

As trimethylamine (TMA) is widely used in agriculture and industry, inhalation of TMA can cause very serious negative effects on human health. However, most of the current gas sensors for detecting TMA are commonly performed at high temperatures and cannot meet market needs. Inspired by this, we prepared imine covalent organic frameworks (TB-COF) synthesized from two monomers, 1,3,5-tris(4-aminophenyl)benzene (TAPB) and 1,3,5-benzotricarboxaldehyde (BTCA), using acetic acid as a catalyst at room temperature. Based on this, three sensors were prepared for gas sensitivity testing, namely, TA, BT, and TB-COF sensors. The three sensors were tested for 15 different gases at room temperature. From the whole gas sensitivity data, the TB-COF sensor made by compositing TA and BT has a higher sensitivity (6845.9%) to TMA at 500 ppm, which is 6.1 and 5.4 times higher than the response of TA and BT sensors, respectively. The TB-COF sensor adsorbs and desorbs TMA in a controlled 23 s cycle with a low detection limit of 28.6 ppb. This result indicates that TB-COF prepared at room temperature can be used as a gas-sensitive sensing material for real-time monitoring of TMA. The gas sensing results demonstrate the great potential of COFs for sensor development and application and provide ideas for further development of COFs-based gas sensors.


Asunto(s)
Iminas , Estructuras Metalorgánicas , Metilaminas , Metilaminas/análisis , Metilaminas/química , Iminas/química , Estructuras Metalorgánicas/química , Límite de Detección , Gases/química , Gases/análisis
16.
ACS Nano ; 18(20): 12808-12819, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38717026

RESUMEN

Considerable progress has already been made in sweat sensors based on electrochemical methods to realize real-time monitoring of biomarkers. However, realizing long-term monitoring of multiple targets at the atomic level remains extremely challenging, in terms of designing stable solid contact (SC) interfaces and fully integrating multiple modules for large-scale applications of sweat sensors. Herein, a fully integrated wristwatch was designed using mass-manufactured sensor arrays based on hierarchical multilayer-pore cross-linked N-doped porous carbon coated by reduced graphene oxide (NPCs@rGO-950) microspheres with high hydrophobicity as core SC, and highly selective monitoring simultaneously for K+, Na+, and Ca2+ ions in human sweat was achieved, exhibiting near-Nernst responses almost without forming an interfacial water layer. Combined with computed tomography, solid-solid interface potential diffusion simulation results reveal extremely low interface diffusion potential and high interface capacitance (598 µF), ensuring the excellent potential stability, reversibility, repeatability, and selectivity of sensor arrays. The developed highly integrated-multiplexed wristwatch with multiple modules, including SC, sensor array, microfluidic chip, signal transduction, signal processing, and data visualization, achieved reliable real-time monitoring for K+, Na+, and Ca2+ ion concentrations in sweat. Ingenious material design, scalable sensor fabrication, and electrical integration of multimodule wearables lay the foundation for developing reliable sweat-sensing systems for health monitoring.


Asunto(s)
Sudor , Dispositivos Electrónicos Vestibles , Muñeca , Sudor/química , Factores de Tiempo , Electrólitos/análisis , Grafito/química , Porosidad , Carbono/química , Cationes/química , Humanos , Monitoreo Biológico/instrumentación
17.
JMIR Hum Factors ; 11: e47996, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38819905

RESUMEN

BACKGROUND: Complementing digital adherence technologies (DATs) with mobile money incentives may improve their utility in supporting tuberculosis medication adherence, yet the feasibility and acceptability of this integrated approach remain unclear. OBJECTIVE: This study aims to describe the feasibility and acceptability of a novel DAT intervention called My Mobile Wallet composed of real-time adherence monitoring, SMS text message reminders, and mobile money incentives for tuberculosis medication adherence in a low-income setting. METHODS: We purposively recruited people living with tuberculosis from the Mbarara Regional Referral Hospital in Mbarara, Uganda, who (1) were starting tuberculosis treatment at enrollment or within the past 4 weeks, (2) owned a mobile phone, (3) were able to use SMS test messaging, (4) were aged ≥18 years, and (5) were living in Mbarara district. At study exit (month 6), we used interviews and questionnaires informed by the unified theory of acceptance and use of technology (UTAUT) to collect feasibility and acceptability data, reflecting patients' experiences of using each component of My Mobile Wallet. Feasibility also included tracking the functionality of the adherence monitor (ie, an electronic pillbox) as well as SMS text message and mobile money delivery. We used a content analytical approach to inductively analyze qualitative data and Stata (version 13; StataCorp LLC) to analyze quantitative data. RESULTS: All 39 participants reported that the intervention was feasible because it was easy for them to use (eg, access and read SMS text messages) and worked as expected. Almost all SMS text messages (6880/7064, 97.4%) were sent as planned. The transmission of adherence data from the monitor worked well, with 98.37% (5682/5776) of the data transmitted as planned. All participants additionally reported that the intervention was acceptable because it helped them take their tuberculosis medication as prescribed; the mobile money incentives relieved them of tuberculosis-related financial burdens; SMS text message reminders and electronic pillbox-based alarms reminded them to take their medication on time; and participants perceived real-time adherence monitoring as "being watched" while taking their medication, which encouraged them to take their medication on time to demonstrate their commitment. The intervention was perceived as a sign of care, which eventually created emotional support and a sense of connectedness to health care. Participants preferred daily SMS text message reminders (32/39, 82%) to reminders linked to missed doses (7/39, 18%), citing the fact that tuberculosis medication is taken daily. CONCLUSIONS: The use of real-time adherence monitoring linked to SMS text message reminders and mobile money incentives for tuberculosis medication adherence was feasible and acceptable in a low-resource setting where poverty-based structural barriers heavily constrain tuberculosis treatment and care.


Asunto(s)
Estudios de Factibilidad , Cumplimiento de la Medicación , Motivación , Sistemas Recordatorios , Envío de Mensajes de Texto , Tuberculosis , Humanos , Cumplimiento de la Medicación/estadística & datos numéricos , Masculino , Femenino , Adulto , Tuberculosis/tratamiento farmacológico , Tuberculosis/psicología , Uganda , Sistemas Recordatorios/instrumentación , Persona de Mediana Edad , Encuestas y Cuestionarios , Teléfono Celular , Investigación Cualitativa , Antituberculosos/uso terapéutico , Antituberculosos/administración & dosificación
18.
Photodiagnosis Photodyn Ther ; 47: 104225, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38821240

RESUMEN

The global health issue of prostate cancer (PCa) requires better diagnosis and treatment. Photoacoustic imaging (PAI) may change PCa management. This review examines PAI's principles, diagnostic role, and therapeutic guidance. PAI uses optical light excitation and ultrasonic detection for high-resolution functional and molecular imaging. PAI uses endogenous and exogenous contrast agents to distinguish cancerous and benign prostate tissues with greater sensitivity and specificity than PSA testing and TRUS-guided biopsy. In addition to diagnosing, PAI can guide and monitor PCa therapy. Its real-time imaging allows precise biopsies and brachytherapy seed placement. Photoacoustic temperature imaging allows non-invasive monitoring of thermal therapies like cryotherapy, improving treatment precision and success. Transurethral illumination probes, innovative contrast agents, integration with other imaging modalities, and machine learning analysis are being developed to overcome depth and data complexity restrictions. PAI could become an essential tool for PCa diagnosis and therapeutic guidance as the field advances.


Asunto(s)
Técnicas Fotoacústicas , Neoplasias de la Próstata , Humanos , Técnicas Fotoacústicas/métodos , Masculino , Neoplasias de la Próstata/terapia , Neoplasias de la Próstata/diagnóstico por imagen
19.
Biosensors (Basel) ; 14(5)2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38785710

RESUMEN

The rise of DNA nanotechnology has driven the development of DNA-based molecular machines, which are capable of performing specific operations and tasks at the nanoscale. Benefitting from the programmability of DNA molecules and the predictability of DNA hybridization and strand displacement, DNA-based molecular machines can be designed with various structures and dynamic behaviors and have been implemented for wide applications in the field of biosensing due to their unique advantages. This review summarizes the reported controlling mechanisms of DNA-based molecular machines and introduces biosensing applications of DNA-based molecular machines in amplified detection, multiplex detection, real-time monitoring, spatial recognition detection, and single-molecule detection of biomarkers. The challenges and future directions of DNA-based molecular machines in biosensing are also discussed.


Asunto(s)
Técnicas Biosensibles , ADN , Nanotecnología , Hibridación de Ácido Nucleico , Humanos
20.
Front Neurol ; 15: 1400455, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38711559

RESUMEN

Purpose: The significance of atraumatic electrode array (EA) insertion in cochlear implant (CI) surgery is widely acknowledged, with consensus that forces due to EA insertion are directly correlated with insertion trauma. Unfortunately, the manual perception of these forces through haptic feedback is inherently limited, and techniques for in vivo force measurements to monitor the insertion are not yet available. Addressing this gap, we developed of a force-sensitive insertion tool capable of capturing real-time insertion forces during standard CI surgery. Methods: This paper describes the tool and its pioneering application in a clinical setting and reports initial findings from an ongoing clinical study. Data and experiences from five patients have been evaluated so far, including force profiles of four patients. Results: The initial intraoperative experiences are promising, with successful integration into the conventional workflow. Feasibility of in vivo insertion force measurement and practicability of the tool's intraoperative use could be demonstrated. The recorded in vivo insertion forces show the expected rise with increasing insertion depth. Forces at the end of insertion range from 17.2 mN to 43.6 mN, while maximal peak forces were observed in the range from 44.8 mN to 102.4 mN. Conclusion: We hypothesize that this novel method holds the potential to assist surgeons in monitoring the insertion forces and, thus, minimizing insertion trauma and ensuring better preservation of residual hearing. Future data recording with this tool can form the basis of ongoing research into the causes of insertion trauma, paving the way for new and improved prevention strategies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...