Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 891
Filtrar
1.
Front Med (Lausanne) ; 11: 1432780, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39224608

RESUMEN

Background: As one of several refractive surgeries, Implant Collamer Lens (ICL) surgery offers stable biocompatibility and consistent, high-quality visual outcomes. ICL has become an effective complement to corneal refractive surgery, gradually becoming one of the mainstream methods for correcting refractive errors. This study employs bibliometric methods to analyze research on ICL surgery to understand the progress, hotspots, and potential future trends in this field. Methods: This study performed a bibliometric analysis of all ICL-related articles collected from the Web of Science Core Collection database between January 1st, 1996, and December 31st, 2023. The CiteSpace 6.2.R4 tool, Excel and the Web of Science website were used to analyze data by country, institution, keywords, and clusters of keywords. Additionally, an in-depth interpretation and analysis were conducted on the field's high-impact articles. Results: Since the first clinical application report of ICL, there have been a total of 875 studies. The number of papers published annually has shown an overall increasing trend. Studies published from China are the most numerous, accounting for 29.14% (n = 255) of the total. Among the institutions, Fudan University and Kitasato University both have published more than 50 papers, with Kitasato University having the highest H-index of 26. The journals with the top 10 publication volumes are all specialized in ophthalmology. The burst keywords since the introduction of ICL surgery have been "intraocular lens," "refractive surgery," and "cataract surgery." The current burst keywords include "visual quality," "vector analysis," "axial length," etc. The results of keyword clustering included ICL, pIOL, high myopia, axial length, optical quality, refractive surgery, ICL implantation, and pupil size. In the High-impact Articles, it was found that the high-impact articles predominantly focus on the safety, efficacy, and predictability of ICL surgery. Conclusion: Research on ICL has grown since its clinical introduction, with the advent of the central hole ICL sparking a surge in recent hotspots, particularly in China. Current hotpots in the field of ICL surgery are "visual quality," "ICL implantation," "vector analysis," "axial length," "evo ICL," "ICL v4c," and "ICL." ICL surgery research trends have evolved from implantation techniques to biological parameters associated with ICL surgery and the benefits of new ICL designs.

2.
BMC Ophthalmol ; 24(1): 397, 2024 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-39243067

RESUMEN

BACKGROUND: To explore intraocular lens (IOL) preferences of United Kingdom-based (UK) refractive surgeons in cataract and refractive lens exchange (RLE) surgery. METHODS: An online survey on IOL preferences (and reasons for their choice) in cataract and RLE surgery was distributed. It also enquired about implementing mini-monovision with extended depth of field (EDoF) IOLs, about utilising IOL mix-and-match (different IOL types in each eye), and at what level of corneal astigmatism they prefer toric lenses. RESULTS: Following an 81.6% response rate, thirty responses were analysed; median years of refractive surgery experience was 12.5. The most popular IOL choices for cataract surgery were EDoF lenses (30%), monofocals (20%), and trifocals (20%). The most cited reason for each was better overall visual outcomes (88.9%), fewer unwanted symptoms (66.7%) and best spectacle independence (66.7%), respectively. For RLE, EDoF remained most popular (36.7%), followed by trifocals (30%), and multifocals (16.7%) with the same reasons for choice cited above. Mini-monovision with EDoF lenses was well-regarded (83% recommend for most/select patients), unlike utilising IOL mix-and-match (60% did not recommend). 40% prefer toric IOLs for astigmatism of 1 dioptre (D) or higher, whilst 30% opt for them at < 1D. CONCLUSIONS: Experienced UK refractive surgeons prefer newer IOLs with enhanced optics; ≥50% of respondents favoured either EDoF or trifocals for a 'typical' cataract or RLE patient. Notably, respondents have a low corneal astigmatism threshold for toric lenses. Mini-monovision with EDoF IOLs was well-regarded, whilst mix-and-match of different IOL types was less recommended.


Asunto(s)
Lentes Intraoculares , Humanos , Reino Unido , Encuestas y Cuestionarios , Implantación de Lentes Intraoculares , Extracción de Catarata , Agudeza Visual/fisiología , Femenino , Masculino , Persona de Mediana Edad
3.
Clin Ophthalmol ; 18: 2467-2472, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39246558

RESUMEN

Refractive surgery has experienced substantial advancements over the past few years, driven by innovative techniques and continuous technological progress aimed at enhancing visual outcomes and patient satisfaction. Refractive errors such as myopia, hyperopia, and astigmatism affect a significant portion of the global population, impacting quality of life and productivity. Recent advancements have been fueled by a deeper understanding of ocular biomechanics and visual optics, leading to more precise and effective treatments. Traditional methods such as LASIK and PRK have been refined, and new procedures like SMILE (Small Incision Lenticule Extraction) have been introduced, expanding the range of treatable refractive errors and improving safety and predictability. Customized treatments, such as wavefront-guided LASIK and topography-guided PRK, allow for individualized plans tailored to each patient's unique corneal characteristics, enhancing visual acuity and reducing higher-order aberrations. The use of femtosecond lasers in procedures like Femto-LASIK and femtosecond laser-assisted cataract surgery (FLACS) offers unparalleled precision, reducing surgical risks and improving outcomes. Implantable Collamer Lenses (ICLs) and corneal crosslinking (CXL) have emerged as effective options for specific patient groups. Advanced diagnostic tools like optical coherence tomography (OCT) and Scheimpflug imaging have improved surgical planning and complication management. As research and technology continue to evolve, these advancements promise even greater improvements in refractive surgery, addressing the visual needs of the global population.

4.
Artículo en Inglés | MEDLINE | ID: mdl-39103696

RESUMEN

PURPOSE: The current study aimed to describe the distribution of angle alpha and angle kappa offsets as well as their associated ocular biometric parameters in a large population of candidates for cataract surgery. METHODS: This cross-sectional retrospective study included 8,119 eyes of 4,781 candidates for cataract surgery (mean age 70.7 ± 12.9 years). There were 49.9% right eyes, and 53.0% patients were females. The angles offset and ocular biometric parameters were measured by the IOLMaster 700 (Carl Zeiss Meditec, AG, Germany). RESULTS: Patient's age and gender, and most of their ocular biometric measurements were similar for the right and left eyes except for pupil diameter (4.01 ± 1.18 vs. 3.92 ± 1.14 mm, respectively, P < 0.001). The angle alpha offset magnitude was similar for the right and left eyes (0.50 ± 0.20 and 0.51 ± 0.21 mm, P = 0.08), whereas the angle kappa offset magnitude was greater in the right eyes (0.37 ± 0.21 vs. 0.33 ± 0.20 mm, P < 0.001). The angle kappa offset magnitudes were greater in the right eyes compared to the left eyes for both males (0.36 ± 0.21 vs. 0.33 ± 0.21 mm, respectively, P < 0.001) and females (0.37 ± 0.20 vs. 0.34 ± 0.20 mm, respectively, P < 0.001). The offset magnitudes of both angles varied significantly according to gender, eye laterality, angle location, and biometric parameters (e.g., axial length). The offset magnitudes of both angles were positively correlated in both right and left eyes. CONCLUSIONS: The offset magnitudes of both the angle alpha and angle kappa present significant variations according to gender, eye laterality, angle location, and biometric parameters, such as AL. These values are also population-specific.

5.
J Clin Med ; 13(15)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39124559

RESUMEN

Background/Objectives: This retrospective case series analyzed visual outcomes in patients with a prior history of implantable collamer lens (ICL) implantation who underwent cataract extraction (CE). A secondary aim was to investigate the relationship between vault height and the rate of cataract development. Methods: Visual acuity and refraction measurements were collected after CE at one week, one month and six months. Vault height measurements were correlated to the time until symptomatic cataracts were removed. Results: A total of 44 eyes were analyzed at six months after CE with efficacy and safety indexes of 1.20 ± 1.11 and 1.50 ± 1.06, respectively. In addition, 70% of eyes had a post-operative uncorrected distance visual acuity (UDVA) within one line of pre-operative corrected distance visual acuity (CDVA). Refractive predictability at six months demonstrated that 43% and 69% of eyes were within ±0.25 D and ±0.50 D of SEQ target, respectively. Astigmatism measured by refractive cylinder was ≤0.25 D in 17% and ≤0.50 D in 34% of eyes pre-operatively compared to 40% and 60% of eyes, respectively, at six months post-operatively. Vault heights one week after ICL (p < 0.0081) and one week before CE (p < 0.0154) demonstrated a positive linear regression with the time until CE. Conclusions: This sample population achieved favorable visual outcomes six months after CE, similar to six months after ICL implantation. Patients with a history of ICL implantation will similarly have a good visual prognosis after CE.

6.
J Clin Med ; 13(15)2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39124578

RESUMEN

In this paper, we summarize the current knowledge on refractive surgery performed in the myopic pediatric population. We describe the main concerns about refractive surgery in myopic children and the indications for refractive surgery in this age group. We present a range of surgical procedures that are being used for the management of unilateral/bilateral myopia in children: corneal refractive surgery (PRK, LASEK, LASIK, FS-LASIK and SMILE) and intraocular refractive surgery (phakic intraocular lens implantation, refractive lens exchange or clear lens extraction), with both their advantages and drawbacks. We also describe the various complications and measures to prevent them.

7.
Sci Rep ; 14(1): 18364, 2024 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-39112522

RESUMEN

The objective of this study was to investigate the culture positivity and distribution of the conjunctival sac bacteria in the perioperative period of corneal refractive surgery. The selected time points of the perioperative period included before the use of antibiotic eye drops, before eye wash (after the use of antibiotic eye drops), after eye wash, and immediately after surgery. Conjunctival specimens obtained at the four time points were cultured to detect the positivity and distribution of bacteria. Before prophylactic antibiotic eye drops were administered, 49 eyes (50%) had positive bacterial culture results, with 45 isolates (91.8%) identified as Staphylococcus epidermidis. The culture positivity rates of the conjunctival sac specimens before eye wash, after eye wash, and immediately after surgery were 19.4%, 3.1%, and 4.1%, respectively. The difference was significant before and after the use of antibiotics and before and after eye wash (both P < 0.001). Staphylococcus epidermidis was the major pathogen in the conjunctival sac before corneal refractive surgery, and the culture positivity rate of the conjunctival bacteria was higher in males. Sixteen of 37 eyes (43.2%) with contact lenses had positive culture results, compared to 33 of 61 eyes (54.1%) without contact lenses (P > 0.05). The judicious preoperative use of antibiotic eye drops combined with the surgical sterile eye wash procedure maximised the removal of conjunctival sac bacteria. Skilled surgical manipulations generally did not increase the risk of infection.


Asunto(s)
Antibacterianos , Conjuntiva , Periodo Perioperatorio , Procedimientos Quirúrgicos Refractivos , Staphylococcus epidermidis , Humanos , Conjuntiva/microbiología , Masculino , Femenino , Procedimientos Quirúrgicos Refractivos/efectos adversos , Adulto , Staphylococcus epidermidis/aislamiento & purificación , Persona de Mediana Edad , Antibacterianos/uso terapéutico , Antibacterianos/administración & dosificación , Córnea/microbiología , Córnea/cirugía , Adulto Joven , Soluciones Oftálmicas , Profilaxis Antibiótica/métodos , Bacterias/aislamiento & purificación , Bacterias/clasificación
8.
BMC Ophthalmol ; 24(1): 362, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39174922

RESUMEN

PURPOSE: To investigate the three-year visual, refractive outcomes and adverse events of the Eyecryl toric phakic IOL (pIOL) for moderate-to-high myopic astigmatism. METHODS: This retrospective study included eligible patients who underwent refractive surgery in one or both eyes with Eyecryl toric pIOL for myopic astigmatism. The efficacy, safety, predictability, rotational stability, vector analysis, and adverse events were evaluated in patients with spherical refraction from - 4.50 to -17.00 diopters (D) and cylindrical refraction from - 0.75 to -5.50 D. RESULTS: Fifty-two eyes of 28 patients were included in the study. The mean efficacy and safety index were 1.12 ± 0.35 and 1.38 ± 0.42, respectively. The mean manifest refraction spherical equivalent was - 10.06 ± 2.69 D and - 0.64 ± 0.61 D preoperatively and postoperatively at 36 months, respectively. The mean manifest astigmatism was - 2.06 ± 1.16 D and - 0.44 ± 0.48 D preoperatively and 36 months postoperative, respectively. During the final examination, 70% of the eyes showed an increase in CDVA of one or more lines compared to their preoperative state. There was a cumulative endothelial cell loss of 3.1% at 36 months postoperatively. One eye developed visually significant anterior subcapsular opacity, whereas another eye experienced pIOL opacification. CONCLUSION: The Eyecryl toric pIOL demonstrated satisfactory visual acuity and refractive outcomes, as assessed by efficacy, safety and stability over a three-year period.


Asunto(s)
Astigmatismo , Implantación de Lentes Intraoculares , Lentes Intraoculares Fáquicas , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Agudeza Visual/fisiología , Adulto , Refracción Ocular/fisiología , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Diseño de Prótesis , Miopía/cirugía , Miopía/fisiopatología , Estudios de Seguimiento , Adulto Joven , Resultado del Tratamiento
9.
Cureus ; 16(7): e64768, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39156271

RESUMEN

Introduction Large language models such as OpenAI's (San Francisco, CA) ChatGPT-3.5 hold immense potential to augment self-directed learning in medicine, but concerns have risen regarding its accuracy in specialized fields. This study compares ChatGPT-3.5 with an internet search engine in their ability to define the Randleman criteria and its five parameters within a self-directed learning environment. Methods Twenty-three medical students gathered information on the Randleman criteria. Each student was allocated 10 minutes to interact with ChatGPT-3.5, followed by 10 minutes to search the internet independently. Each ChatGPT-3.5 conversation, student summary, and internet reference were subsequently analyzed for accuracy, efficiency, and reliability. Results ChatGPT-3.5 provided the correct definition for 26.1% of students (6/23, 95% CI: 12.3% to 46.8%), while an independent internet search resulted in sources containing the correct definition for 100% of students (23/23, 95% CI: 87.5% to 100%, p = 0.0001). ChatGPT-3.5 incorrectly identified the Randleman criteria as a corneal ectasia staging system for 17.4% of students (4/23), fabricated a "Randleman syndrome" for 4.3% of students (1/23), and gave no definition for 52.2% of students (12/23). When a definition was given (47.8%, 11/23), a median of two of the five correct parameters was provided along with a median of two additional falsified parameters. Conclusion Internet search engine outperformed ChatGPT-3.5 in providing accurate and reliable information on the Randleman criteria. ChatGPT-3.5 gave false information, required excessive prompting, and propagated misunderstandings. Learners should exercise discernment when using ChatGPT-3.5. Future initiatives should evaluate the implementation of prompt engineering and updated large-language models.

10.
Am J Transl Res ; 16(7): 3072-3080, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39114735

RESUMEN

AIMS: To investigate the impact of different corneal diameters on corneal morphology and biomechanical outcome during preoperative screening for corneal refractive surgery. METHODS: A retrospective analysis was conducted on 300 patients who underwent corneal refractive surgery at Eye and ENT Hospital, Fudan University between October 2023 and December 2023. All patients had no history of keratoconus or previous corneal surgery. Patients were categorized into two groups based on corneal topography measurements: (1) normal corneal diameter group (n=159), those with corneal diameter ranging from 11.5 mm to 12.0 mm; (2) abnormal corneal diameter group (n=141), those with corneal diameter smaller than 10.0 mm or larger than 12.5 mm. Corneal thickness, morphologic data, and biomechanical data were measured using Pentacam corneal topography. Correlation analysis was conducted to explore the relationship between corneal diameter and various corneal topography and biomechanical data. RESULTS: Significant differences were observed in corneal topography data including BFSf (F=43.21), BFSb (F=30.24), Df (F=15.32), Dp (F=32.36), Da (F=9.66), D (F=58.36), PPIavg (F=32.64), and ARTmax (F=12.06) between the groups (P<0.05). Additionally, BFSf, BFSb, Db, Dp, D, and PPIavg exhibited statistically significant differences between any two groups (P<0.05). Significant differences were also found in Df, Da, and ARTmax between small and large corneas, as well as between normal-sized and large corneas (P<0.05). Correlation analysis indicated negative correlations between corneal diameter and A1V (r=-0.12), HCdArcLength (r=-0.17), CBI (r=-0.27), bIOP (r=-0.13), Df (r=-0.025), PPIavg (r=-0.028), and TBI (r=-0.27). Conversely, BFSf (r=0.009), BFSb (r=0.001), PD (r=0.15), and ARTH (r=0.37) displayed positive correlations with corneal diameter. CONCLUSIONS: Corneal diameter significantly affects preoperative screening for corneal refractive surgery. Smaller corneal diameters exhibit a greater influence on the corneal topography BAD analysis system.

11.
Eur J Ophthalmol ; : 11206721241267277, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39119830

RESUMEN

PURPOSE: In Descemet Membrane Endothelial Keratoplasty (DMEK) a gas bubble is usually used to attach the graft to the host cornea. In this study, we observed the bubble size and bubble-graft coverage at different gaze angles following DMEK. METHODS: This observational prospective study analyzed 465 images of patients who underwent an uneventful DMEK. Intraoperatively, the anterior chamber was filled up to 90% of its volume with a 20% Sulfur Hexafluoride (SF6) gas-air mixture. Postoperatively, the bubble was photographed daily in different gaze angles ranging from a supine position (0°) to an upright position (90°) and a slightly inclined position (105°). The primary outcomes were bubble-graft coverage and bubble diameters depending on the gaze angle and time after DMEK. RESULTS: The highest bubble-graft coverage was achieved at a 0° gaze angle at all times of measurement. In the first 48 h after DMEK, the mean bubble-graft coverage was over 85% at a gaze angle between 0° and 45°. Starting 72 h after DMEK, the graft coverage declined at all gaze angles. The graft coverage at a 0° gaze angle was 88.61 ± 10.90% after 96 postoperative hours, while the graft coverage was below 85% at all other gaze angles. CONCLUSION: Our clinical results provide novel insight into variation in bubble-graft coverage as a function of gaze angle and may be used to aid in patient counselling for appropriate body positioning following DMEK to prevent early graft detachment. Maintaining supine positioning seems to be most advantageous starting 48 h after DMEK.

12.
Cureus ; 16(7): e65503, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39188422

RESUMEN

To assess the minimal change in visual acuity perceived by patients as important in different eye-related interventions. PubMed was utilized to search articles on each of the four major interventions: cataract surgery, keratoplasty, different glaucoma treatments, and refractive eye surgery, each combined with quality of life (QoL) and visual acuity keywords. The search was narrowed to articles between 2000 and 2023. Seventy-four major articles were thus reviewed. Of these, 27 studies reviewed the results of cataract surgery, 20 studies discussed the effect of keratoplasty interventions on the vision-related QoL (VRQoL), most showing that VRQoL improved significantly after keratoplasty, 11 studies investigated the effect of different glaucoma interventions on patients' visual acuity and the QoL, 16 studies reviewed refractive surgery, where they showed an improved QoL in most of the cases, although some of the studies showed a slight superiority of one intervention over the other in the short term. The minimally important difference (MID) perceived in visual acuity depends mainly on the type of surgical intervention (keratoplasty, glaucoma, or refractive surgery), and the impact on QoL on improved visual acuity differs depending on the intervention.

13.
Biosensors (Basel) ; 14(8)2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39194600

RESUMEN

Noninvasive in situ monitoring of viscoelastic characteristics of corneal tissue at elevated temperatures is pivotal for mechanical property-informed refractive surgery techniques, including thermokeratoplasty and photorefractive keratectomy, requiring precise thermal modifications of the corneal structure during these surgical procedures. This study harnesses Brillouin light scattering spectroscopy as a biosensing platform to noninvasively probe the viscoelastic properties of ovine corneas across a temperature range of 25-64 °C. By submerging the tissue samples in silicone oil, consistent hydration and immiscibility are maintained, allowing for their accurate sensing of temperature-dependent mechanical behaviors. We identify significant phase transitions in the corneal tissue, particularly beyond 40 °C, likely due to collagen unfolding, marking the beginning of thermal destabilization. A subsequent transition, observed beyond 60 °C, correlates with collagen denaturation. These phase transformations highlight the cornea's sensitivity to both physiologically reversible and irreversible viscoelastic changes induced by mild to high temperatures. Our findings underscore the potential of the Brillouin biosensing technique for real-time diagnostics of corneal biomechanics during refractive surgeries to attain optimized therapeutic outcomes.


Asunto(s)
Técnicas Biosensibles , Córnea , Elasticidad , Animales , Ovinos , Viscosidad , Transición de Fase , Temperatura
14.
Int Ophthalmol ; 44(1): 355, 2024 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-39182212

RESUMEN

PURPOSE: ReLEx (Refractive Lenticule Extraction) Small Incision Lenticule Extraction (SMILE), the second generation of ReLEx Femtosecond Lenticule Extraction (FLEx), is a minimally invasive, flapless procedure designed to treat refractive errors such as myopia, hyperopia, presbyopia, and astigmatism. This review aims to provide a comprehensive overview of the methods for preserving SMILE-derived lenticules and discusses their potential future applications. METHODS: A narrative literature review was conducted using PubMed, Scopus, and Web of Science databases, focusing on articles published up to January 2024 and available in English. The authors also evaluated the reference lists of the collected papers to identify any additional relevant research. RESULTS: No standardized protocols currently exist for the storage or clinical application of SMILE-derived lenticules. However, these lenticules present a promising resource for therapeutic uses, particularly in addressing the shortage of donor corneal tissues. Their potential applications include inlay and overlay additive keratoplasty, as well as other ocular surface applications. Further research is needed to establish reliable protocols for their preservation and clinical use. CONCLUSION: SMILE-derived lenticules offer significant potential as an alternative to donor corneal tissues. Standardizing their storage and application methods could enhance their use in clinical settings.


Asunto(s)
Sustancia Propia , Bancos de Ojos , Humanos , Sustancia Propia/cirugía , Sustancia Propia/patología , Bancos de Ojos/métodos , Trasplante de Córnea/métodos , Cirugía Laser de Córnea/métodos , Donantes de Tejidos , Láseres de Excímeros/uso terapéutico , Refracción Ocular/fisiología
15.
Am J Ophthalmol ; 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39168367

RESUMEN

PURPOSE: Children with autism spectrum disorder (ASD) and intellectual disability (ID) often cannot tolerate wearing spectacles or contact lenses, which are the standard of care for treating ametropia.1,2. We aimed to assess the impact of refractive surgery on social functioning and vision-specific quality of life in this population. DESIGN: Prospective, before-and-after case series. METHODS: SETTING: Single, academic tertiary care center. STUDY POPULATION: 18 children with ASD and/or ID, ametropia, and spectacle non-adherence were included in the analysis. PROCEDURE: Participants underwent refractive surgery with either intraocular lens implantation or keratectomy. Parents completed the Social Responsiveness Scale (SRS-2) and Pediatric Eye Questionnaire (PedEyeQ) at baseline and 1, 6, and 12 months post-surgery.3,4 MAIN OUTCOME MEASURES: Median change in SRS-2 T-scores and PedEyeQ scores 12 months after surgery, compared to baseline. The minimum clinically important difference (MCID) was set at 5 points for the SRS-2 and 10 points for the PedEyeQ. RESULTS: At 12 months after surgery, statistically significant improvements were observed in the SRS-2 domains of Social Awareness (8 points, 95% CI 2 to 13, p = .03) and Social Motivation (7 points, 95% CI 2 to 15, p = .03). Total SRS-2 T-score improved in a clinically important manner for 56% (10/18) of patients, but the median change was not statistically significant (5 points, 95% CI -1 to 9, p = .10). Vision-specific quality of life showed statistically significant improvements in the domains of Functional Vision (40 points, 95% CI 7 to 73, p = .02) and Bothered by Eyes/Vision (23 points, 95% CI 3 to 45, p = .02). CONCLUSIONS: Refractive surgery led to clinically and statistically significant improvements in domains of social functioning and vision-specific quality of life at 12 months after surgery. A narrow majority of patients demonstrated a clinically important improvement in overall social functioning, but these changes were not statistically significant. The results suggest that refractive surgery in children with neurodevelopmental disorders, ametropia, and spectacle non-adherence may provide developmental and quality of life benefits. Larger, controlled studies are required to validate these findings.

16.
Eur J Ophthalmol ; : 11206721241278395, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39169780

RESUMEN

PURPOSE: Compare refractive results between mechanical PRK (mPRK) and transepithelial PRK (tPRK) with WaveLight Allegretto EX500 excimer laser system (Alcon Laboratories, Fort Worth, TX, USA). SETTING: Department of Ophthalmology of the Federal University of Sao Paulo, Brazil. DESIGN: Prospective and randomized study. METHODS: In 151 eyes of 73 patients with astigmatism and myopia, both eyes had similar refraction before surgery, with a maximum of 15-µm difference in ablation who underwent mPRK in one eye and tPRK in the contralateral eye. The mean age of the patients in this study was 31.45 ± 6.97 years (range, 22 to 54 years). RESULTS: A comparison was made with all variables between the two groups, and we found that UDVA and SE were worse in the tPRK group at six months than in the mPRK group. In the mPRK group, there was a higher frequency in the +/- 0.50 range and a lower frequency in the +/- 1.50 range. In the tPRK group, however, there was a lower frequency in the +/- 0.50 range and a higher frequency in the +/- 1.50 range. Concerning gain or loss of lines of sight, there was no association between the two groups (chi-square test, p = 0.887). CONCLUSION: Both mPRK and tPRK appear to have similar safety. However, mPRK was associated with significantly better UDVA and SE six months post-operatively.

17.
Case Rep Ophthalmol ; 15(1): 565-571, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39144640

RESUMEN

Introduction: Amphetamine-based medications such as Adderall®, used for the treatment of attention deficit-hyperactivity disorder (ADHD), may theoretically elicit angle closure through their adrenergic mechanisms. The relationship between the use of implantable collamer lenses (ICLs) and angle closure has been extensively investigated based on appropriate vault and lens sizing and postoperative changes in the anterior chamber angle (ACA) and corneal morphology. This case reflects a synergistic impact from both Adderall® use and ICL implantation for the proposed mechanism of angle closure. Case Presentation: A 36-year-old myopic female with ADHD controlled with Adderall® underwent toric ICL implantation in the right eye after undergoing preoperative laser peripheral iridotomy. Shortly after, the patient developed episodic angle closure in the right eye, with episodes mainly occurring after taking an additional dose of Adderall® in a dimly lit environment. The patient later had an ICL exchange with a smaller sized EVO+ toric ICL in the right eye and remained asymptomatic after. Conclusion: Additive mechanisms from both the ICL and Adderall® were present in our patient. The ICL caused crowding of the ACA through a pseudophacomorphic mechanism, and the Adderall® caused increased iridotrabecular contact secondary to pharmacologic mydriasis. This resulted in episodic angle closure with subsequent spikes in the intraocular pressure. There are no current reports or studies in the current literature describing the combined mechanisms of ICL implantation and Adderall® use in the potential development of angle closure. Further studies may be done to assess interactions of such medications in patients after ICL implantation.

18.
BMC Ophthalmol ; 24(1): 351, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39155380

RESUMEN

PURPOSE: To investigate the repeatability and reproducibility of a new method for centration analysis after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK). METHODS: This study comprised 29 eyes treated with SMILE and 24 with FS-LASIK. Decentrations were analyzed using tangential and pachymetry difference maps respectively. Both difference maps were generated with a Scheimpflug tomographer (Pentacam) for each eye, using preoperative and 3-month postoperative scans. Repeatability and reproducibility were evaluated by calculating the intraclass correlation coefficient (ICC), within-subject standard deviation (Sw), and coefficient of repeatability (CR). RESULTS: ICC, Sw, and CR showed good to excellent repeatability in locating the coordinates of the optical zone (OZ) center on both maps, with values ranging from 0.84 to 0.96, 0.03 to 0.13, and 0.08 to 0.36 respectively. The repeatability of the total decentration from the preoperative corneal vertex on the tangential curvature difference maps( d TC ) and the pachymetry difference maps( d PC ) were moderate and good, respectively. The ICC, Sw, and CR of d TC were 0.63, 0.09, and 0.25, respectively. The ICC, Sw, and CR of d PC were 0.77, 0.10, and 0.28, respectively. The reproducibility of the OZ center measurements was excellent for the tangential difference maps (ICC ≥ 0.97 ) and good for the pachymetry difference maps (ICC ≥ 0.86). ICC, Sw, and CR showed excellent reproducibility of d TC , with values of 0.95, 0.03, and 0.08, respectively. ICC, Sw, and CR showed good reproducibility of d PC , with values of 0.89, 0.06, and 0.17, respectively. CONCLUSION: The centration analysis method used in this study showed good to excellent repeatability and reproducibility in locating the coordinates of the center of the OZ on the tangential and pachymetry difference maps.


Asunto(s)
Córnea , Topografía de la Córnea , Queratomileusis por Láser In Situ , Miopía , Refracción Ocular , Humanos , Reproducibilidad de los Resultados , Femenino , Adulto , Masculino , Queratomileusis por Láser In Situ/métodos , Miopía/cirugía , Adulto Joven , Córnea/cirugía , Córnea/diagnóstico por imagen , Córnea/patología , Refracción Ocular/fisiología , Topografía de la Córnea/métodos , Paquimetría Corneal/métodos , Láseres de Excímeros/uso terapéutico , Agudeza Visual , Cirugía Laser de Córnea/métodos , Persona de Mediana Edad , Periodo Posoperatorio
20.
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA