Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Methods Appl Fluoresc ; 12(3)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38670142

RESUMEN

In the past, there were limited efforts to use light-emitting diodes (LEDs) for pumping solid-state lasers. However, these attempts were overshadowed by the introduction of laser diodes, which offered more favourable pumping conditions. Nevertheless, recent advancements in high-power LEDs, coupled with the utilization of luminescent concentrators (LC), have paved the way for a novel approach to pump solid-state lasers. The combination of LEDs and LC in this LED-LC system presents several advantages, including enhanced ruggedness, stability, and cost-effectiveness compared to other laser pumping methods. This review explores the various techniques employed to pump solid-state lasers using LED-LC as a pump source, along with improvements made to enhance the brightness of LEDs in this context.

2.
Actas dermo-sifiliogr. (Ed. impr.) ; 115(3): 246-257, Mar. 2024. tab, ilus
Artículo en Inglés | IBECS | ID: ibc-231397

RESUMEN

Background: Hereditary haemorrhagic telangiectasia (HHT) is characterized by the presence of telangiectases and larger arteriovenous malformations in different organs. Mucocutaneous telangiectases can bleed and become an aesthetic concern, impairing quality of life (QoL). However, the best treatment approach has not been defined yet. Objective: To evaluate the efficacy and safety of dual wavelength sequential 595/1064nm laser (DWSL) compared to 1064nm laser (Nd:YAG) alone. Secondarily, to evaluate QoL impairment in HHT patients, and its improvement with laser therapy. Methods A comparative randomized split-body double-blinded prospective study (DWSL vs Nd:YAG). Demographic, clinical and treatment characteristics were recorded. The severity and degree of improvement were evaluated by three blinded examiners who scored pre-treatment and post-treatment pictures on a 5-point scale. Patients fulfilled Skindex-29 and FACE-Q® tests and assessed procedure-associated pain and patient satisfaction. Results: 111 treatment areas (55 treated with DWSL and 56 with Nd:YAG) from 26 patients were analyzed. The median number of laser sessions was 2 (interquartile range [IQR] 2–4; mean 2.90 vs 2.88, respectively). The median improvement score, irrespective of location, was significantly higher for Nd:YAG compared to DWSL: 3 (IQR 2–3; mean 2.61) vs 2 (IQR 2–3; mean 2.32), p=0.031. Both FACE-Q index and Skindex-29 test results improved significantly (p<0.001), and 92.4% patients reported a high degree of satisfaction (≥8). No severe adverse events were reported. Conclusions DWSL and Nd:YAG laser are convenient, safe and effective treatment options for mucocutaneous telangiectases in HHT patients. However, Nd:YAG delivered better results with better tolerability. QoL was significantly improved by both treatments. (AU)


Antecedentes: La telangiectasia hemorrágica hereditaria (THH) se caracteriza por la presencia de telangiectasias y malformaciones arteriovenosas de mayor tamaño en diferentes órganos. Las telangiectasias a nivel mucocutáneo pueden sangrar y convertirse en un problema estético, afectando la calidad de vida (CdV). Sin embargo, aún no se ha definido su mejor enfoque terapéutico. Objetivo: Evaluar la eficacia y la seguridad del láser dual secuencial de longitud de onda de 595/1064nm (DWSL) en comparación con el láser de 1064nm (Nd:YAG) solo. Por otro lado, evaluar el deterioro de la calidad de vida en los pacientes con THH y su mejora tras la terapia con láser. Métodos: Estudio prospectivo, doble ciego, aleatorizado, comparativo, de cuerpo dividido (DWSL vs. Nd:YAG). Se registraron las características demográficas, clínicas y del tratamiento. La gravedad y el grado de mejora fueron evaluados por tres examinadores ciegos que calificaron las imágenes previas al tratamiento y posteriores al tratamiento en una escala de 5 puntos. Los pacientes cumplimentaron las pruebas Skindex-29 y FACE-Q® y se evaluó el dolor asociado al procedimiento y la satisfacción del paciente. Resultados: Se analizaron 111 áreas de tratamiento (55 tratadas con DWSL y 56 con Nd:YAG) de 26 pacientes. La mediana del número de sesiones de láser fue de 2 (rango intercuartílico [RIC] 2-4; media 2,90 vs. 2,88, respectivamente). La mediana de la puntuación de mejora, independientemente de la ubicación, fue significativamente mayor para Nd:YAG en comparación con DWSL: 3 (IQR 2-3; media 2,61) frente a 2 (IQR 2-3; media 2,32), p=0,031. Tanto el índice FACE-Q como los resultados de la prueba Skindex-29 mejoraron significativamente (p<0,001), y el 92,4% de los pacientes informaron un alto grado de satisfacción (≥8). No se informaron eventos adversos graves... (AU)


Asunto(s)
Humanos , Telangiectasia Hemorrágica Hereditaria , Láseres de Estado Sólido , Calidad de Vida , Malformaciones Arteriovenosas , Terapia por Láser , Telangiectasia Retiniana , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto
3.
Actas dermo-sifiliogr. (Ed. impr.) ; 115(3): t246-t257, Mar. 2024. tab, ilus
Artículo en Español | IBECS | ID: ibc-231398

RESUMEN

Antecedentes: La telangiectasia hemorrágica hereditaria (THH) se caracteriza por la presencia de telangiectasias y malformaciones arteriovenosas de mayor tamaño en diferentes órganos. Las telangiectasias a nivel mucocutáneo pueden sangrar y convertirse en un problema estético, afectando la calidad de vida (CdV). Sin embargo, aún no se ha definido su mejor enfoque terapéutico. Objetivo: Evaluar la eficacia y la seguridad del láser dual secuencial de longitud de onda de 595/1064nm (DWSL) en comparación con el láser de 1064nm (Nd:YAG) solo. Por otro lado, evaluar el deterioro de la calidad de vida en los pacientes con THH y su mejora tras la terapia con láser. Métodos: Estudio prospectivo, doble ciego, aleatorizado, comparativo, de cuerpo dividido (DWSL vs. Nd:YAG). Se registraron las características demográficas, clínicas y del tratamiento. La gravedad y el grado de mejora fueron evaluados por tres examinadores ciegos que calificaron las imágenes previas al tratamiento y posteriores al tratamiento en una escala de 5 puntos. Los pacientes cumplimentaron las pruebas Skindex-29 y FACE-Q® y se evaluó el dolor asociado al procedimiento y la satisfacción del paciente. Resultados: Se analizaron 111 áreas de tratamiento (55 tratadas con DWSL y 56 con Nd:YAG) de 26 pacientes. La mediana del número de sesiones de láser fue de 2 (rango intercuartílico [RIC] 2-4; media 2,90 vs. 2,88, respectivamente). La mediana de la puntuación de mejora, independientemente de la ubicación, fue significativamente mayor para Nd:YAG en comparación con DWSL: 3 (IQR 2-3; media 2,61) frente a 2 (IQR 2-3; media 2,32), p=0,031. Tanto el índice FACE-Q como los resultados de la prueba Skindex-29 mejoraron significativamente (p<0,001), y el 92,4% de los pacientes informaron un alto grado de satisfacción (≥8). No se informaron eventos adversos graves... (AU)


Background: Hereditary haemorrhagic telangiectasia (HHT) is characterized by the presence of telangiectases and larger arteriovenous malformations in different organs. Mucocutaneous telangiectases can bleed and become an aesthetic concern, impairing quality of life (QoL). However, the best treatment approach has not been defined yet. Objective: To evaluate the efficacy and safety of dual wavelength sequential 595/1064nm laser (DWSL) compared to 1064nm laser (Nd:YAG) alone. Secondarily, to evaluate QoL impairment in HHT patients, and its improvement with laser therapy. Methods: A comparative randomized split-body double-blinded prospective study (DWSL vs Nd:YAG). Demographic, clinical and treatment characteristics were recorded. The severity and degree of improvement were evaluated by three blinded examiners who scored pre-treatment and post-treatment pictures on a 5-point scale. Patients fulfilled Skindex-29 and FACE-Q® tests and assessed procedure-associated pain and patient satisfaction. Results: 111 treatment areas (55 treated with DWSL and 56 with Nd:YAG) from 26 patients were analyzed. The median number of laser sessions was 2 (interquartile range [IQR] 2–4; mean 2.90 vs 2.88, respectively). The median improvement score, irrespective of location, was significantly higher for Nd:YAG compared to DWSL: 3 (IQR 2–3; mean 2.61) vs 2 (IQR 2–3; mean 2.32), p=0.031. Both FACE-Q index and Skindex-29 test results improved significantly (p<0.001), and 92.4% patients reported a high degree of satisfaction (≥8). No severe adverse events were reported. Conclusions: DWSL and Nd:YAG laser are convenient, safe and effective treatment options for mucocutaneous telangiectases in HHT patients. However, Nd:YAG delivered better results with better tolerability. QoL was significantly improved by both treatments. (AU)


Asunto(s)
Humanos , Telangiectasia Hemorrágica Hereditaria , Láseres de Estado Sólido , Calidad de Vida , Malformaciones Arteriovenosas , Terapia por Láser , Telangiectasia Retiniana , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto
4.
Methods Mol Biol ; 2779: 33-68, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38526781

RESUMEN

Lasers for light scattering measurement and fluorescence excitation are essential components of all flow cytometers. Flow cytometers now typically rely on multiple laser wavelengths allowing excitation of a constantly increasing variety of fluorescent probes. The expanding use of spectral flow cytometry to increase the magnitude of multiparametric analysis is also changing the significance of laser choice in cytometry. In this chapter, we review the lasers available for flow cytometry and provide guidance in choosing laser wavelengths and characteristics to best match the needs of modern cell analysis by both conventional and spectral cytometry. We also discuss the recent advances in laser technology as the push to expand the palette of laser wavelength for cytometry continues.


Asunto(s)
Rayos Láser , Luz , Citometría de Flujo , Colorantes Fluorescentes , Nefelometría y Turbidimetría
5.
Actas Dermosifiliogr ; 115(3): T246-T257, 2024 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38185205

RESUMEN

BACKGROUND: Hereditary haemorrhagic telangiectasia (HHT) is characterized by the presence of telangiectases and larger arteriovenous malformations in different organs. Mucocutaneous telangiectases can bleed and become an aesthetic concern, impairing quality of life (QoL). However, the best treatment approach has not been defined yet. OBJECTIVE: To evaluate the efficacy and safety of dual wavelength sequential 595/1064nm laser (DWSL) compared to 1064nm laser (Nd:YAG) alone. Secondarily, to evaluate QoL impairment in HHT patients, and its improvement with laser therapy. METHODS: A comparative randomized split-body double-blinded prospective study (DWSL vs Nd:YAG). Demographic, clinical and treatment characteristics were recorded. The severity and degree of improvement were evaluated by three blinded examiners who scored pre-treatment and post-treatment pictures on a 5-point scale. Patients fulfilled Skindex-29 and FACE-Q® tests and assessed procedure-associated pain and patient satisfaction. RESULTS: 111 treatment areas (55 treated with DWSL and 56 with Nd:YAG) from 26 patients were analyzed. The median number of laser sessions was 2 (interquartile range [IQR] 2-4; mean 2.90 vs 2.88, respectively). The median improvement score, irrespective of location, was significantly higher for Nd:YAG compared to DWSL: 3 (IQR 2-3; mean 2.61) vs 2 (IQR 2-3; mean 2.32), p=0.031. Both FACE-Q index and Skindex-29 test results improved significantly (p<0.001), and 92.4% patients reported a high degree of satisfaction (≥8). No severe adverse events were reported. CONCLUSIONS: DWSL and Nd:YAG laser are convenient, safe and effective treatment options for mucocutaneous telangiectases in HHT patients. However, Nd:YAG delivered better results with better tolerability. QoL was significantly improved by both treatments.


Asunto(s)
Aluminio , Láseres de Colorantes , Láseres de Estado Sólido , Telangiectasia Hemorrágica Hereditaria , Telangiectasia , Itrio , Humanos , Láseres de Colorantes/efectos adversos , Láseres de Estado Sólido/efectos adversos , Neodimio , Estudios Prospectivos , Calidad de Vida , Telangiectasia Hemorrágica Hereditaria/complicaciones , Telangiectasia/etiología , Telangiectasia/radioterapia , Resultado del Tratamiento
6.
Actas Dermosifiliogr ; 115(3): 246-257, 2024 Mar.
Artículo en Inglés, Español | MEDLINE | ID: mdl-37913989

RESUMEN

BACKGROUND: Hereditary haemorrhagic telangiectasia (HHT) is characterized by the presence of telangiectases and larger arteriovenous malformations in different organs. Mucocutaneous telangiectases can bleed and become an aesthetic concern, impairing quality of life (QoL). However, the best treatment approach has not been defined yet. OBJECTIVE: To evaluate the efficacy and safety of dual wavelength sequential 595/1064nm laser (DWSL) compared to 1064nm laser (Nd:YAG) alone. Secondarily, to evaluate QoL impairment in HHT patients, and its improvement with laser therapy. METHODS: A comparative randomized split-body double-blinded prospective study (DWSL vs Nd:YAG). Demographic, clinical and treatment characteristics were recorded. The severity and degree of improvement were evaluated by three blinded examiners who scored pre-treatment and post-treatment pictures on a 5-point scale. Patients fulfilled Skindex-29 and FACE-Q® tests and assessed procedure-associated pain and patient satisfaction. RESULTS: 111 treatment areas (55 treated with DWSL and 56 with Nd:YAG) from 26 patients were analyzed. The median number of laser sessions was 2 (interquartile range [IQR] 2-4; mean 2.90 vs 2.88, respectively). The median improvement score, irrespective of location, was significantly higher for Nd:YAG compared to DWSL: 3 (IQR 2-3; mean 2.61) vs 2 (IQR 2-3; mean 2.32), p=0.031. Both FACE-Q index and Skindex-29 test results improved significantly (p<0.001), and 92.4% patients reported a high degree of satisfaction (≥8). No severe adverse events were reported. CONCLUSIONS: DWSL and Nd:YAG laser are convenient, safe and effective treatment options for mucocutaneous telangiectases in HHT patients. However, Nd:YAG delivered better results with better tolerability. QoL was significantly improved by both treatments.


Asunto(s)
Aluminio , Láseres de Colorantes , Láseres de Estado Sólido , Telangiectasia Hemorrágica Hereditaria , Telangiectasia , Itrio , Humanos , Láseres de Colorantes/efectos adversos , Láseres de Estado Sólido/efectos adversos , Neodimio , Estudios Prospectivos , Calidad de Vida , Telangiectasia Hemorrágica Hereditaria/complicaciones , Telangiectasia/etiología , Telangiectasia/radioterapia , Resultado del Tratamiento
7.
Sensors (Basel) ; 23(16)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37631561

RESUMEN

The 2 µm wavelength belongs to the eye-safe band and has a wide range of applications in the fields of lidar, biomedicine, and materials processing. With the rapid development of military, wind power, sensing, and other industries, new requirements for 2 µm solid-state laser light sources have emerged, especially in the field of lidar. This paper focuses on the research progress of 2 µm solid-state lasers for lidar over the past decade. The technology and performance of 2 µm pulsed single longitudinal mode solid-state lasers, 2 µm seed solid-state lasers, and 2 µm high power solid-state lasers are, respectively, summarized and analyzed. This paper also introduces the properties of gain media commonly used in the 2 µm band, the construction method of new bonded crystals, and the fabrication method of saturable absorbers. Finally, the future prospects of 2 µm solid-state lasers for lidar are presented.

8.
Nanomaterials (Basel) ; 13(15)2023 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-37570488

RESUMEN

All-solid-state Tm lasers have a wider wavelength range and higher output power compared to other types of lasers. In this work, we demonstrate an all-solid-state, high repetition, Tm:YAP laser Q-switched by a graphdiyne (GDY) saturable absorber. The high-quality optical nonlinear material GDY, synthesized by a cross-coupling method, exhibits a strong nonlinear optical response. The application of GDY as a saturable absorber in the passively Q-switched (PQS) Tm:YAP of an all-solid-state laser has been realized with the shortest pulse duration of ~785 ns and repetition frequency of ~199.6 kHz at a central wavelength of 1985.8 nm. This represents the shortest pulse duration and the highest repetition frequency achieved from GDY in a solid-state Tm laser to date. Our work demonstrates the remarkable nonlinear optical properties of GDY, which holds promising potential in the field of optoelectronics.

9.
J Clin Med ; 12(13)2023 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-37445353

RESUMEN

BACKGROUND: To examine the 12-month clinical and refractive outcomes of PRK performed with a UV all-solid-state laser. METHODS: The study included healthy patients with myopia and/or compound myopic astigmatism enrolled for refractive surgery and treated with PRK using a 210 nm wavelength, 2 kHz repetition rate, UV all-solid-state laser (LaserSoft, Katana Technologies GmbH, Kleinmachnow, Germany). All subjects were examined at baseline and after 1, 3, 6, and 12 months after the treatment with a slit lamp, refraction, visual acuity assessment (logMAR chart), tonometry, ophthalmoscopy, and corneal tomography with a Scheimpflug camera. The outcome measures considered were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, central corneal thickness, and transparency. The efficacy, safety, predictability, and stability were determined. RESULTS: The study included 34 eyes of 19 patients. The mean UDVA changed from 1.20 ± 0.43 to -0.05 ± 0.10 logMAR at 12 months, and the mean CDVA changed from -0.03 ± 0.06 to -0.06 ± 0.09 logMAR, respectively. The mean spherical equivalent (SE) changed from -4.90 ± 2.12 D to -0.01 ± 0.40 D and was within ±0.50 D of the intended correction in 91% of eyes and within ±1.00 D in 97% of eyes at 12 months. No eyes lost lines of visual acuity, and 64% of eyes gained one or more lines. CONCLUSIONS: PRK with the 210 nm wavelength, 2 kHz repetition rate, all-solid-state laser LaserSoft system proved to have good visual, refractive, and clinical outcomes after the follow-up at 12 months. The emerging gas-free, solid-state technology might be considered a valid alternative for the gas operating lasers for corneal refractive surgery.

10.
ACS Appl Mater Interfaces ; 15(30): 36628-36635, 2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37481771

RESUMEN

The use of triplet excitons harvesting and short exciton lifetime organic emitters is important to improve the exciton utilization in organic semiconductor laser diodes. In this study, a hybridized local and charge-transfer (HLCT)-type molecule, 11-(3-(10-(4-(1-phenyl-1H-phenanthro[9,10-d]imidazol-2-yl)phenyl)anthracen-9-yl)phenyl)-11H-benzofuro[3,2-b]carbazole (PhAnMBf), is used as an emitter for blue-emitting organic solid-state lasers (OSSLs). The short exciton lifetime and high photoluminescence quantum yield of the PhAnMBf emitter allowed the fabrication of an organic laser with an emission wavelength of 453 nm, a small full width at half-maximum of 1.2 nm, and a threshold of 105 nJ/pulse, corresponding to 44 µJ/cm2, on the distributed feedback substrate. The anthracene-based PhAnMBf material showed the potential of the HLCT emitter as an OSSL.

11.
Sensors (Basel) ; 23(6)2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36991932

RESUMEN

Frequency-difference-stabilized dual-frequency solid-state lasers with tunable and large frequency difference have become an ideal light source for the high-accuracy absolute-distance interferometric system due to their stable multistage synthetic wavelengths. In this work, the advances in research on oscillation principles and key technologies of the different kinds of dual-frequency solid-state lasers are reviewed, including birefringent dual-frequency solid-state lasers, biaxial and two-cavity dual-frequency solid-state lasers. The system composition, operating principle, and some main experimental results are briefly introduced. Several typical frequency-difference stabilizing systems for dual-frequency solid-state lasers are introduced and analyzed. The main development trends of research on dual-frequency solid-state lasers are predicted.

12.
J Clin Med ; 12(2)2023 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-36675659

RESUMEN

In the early 2000s, solid-state lasers emerged as an alternative technology to excimer systems in refractive surgery. Despite some technological limits at the time, good clinical results could be achieved with solid-state laser systems. This prospective case series reports clinical outcomes of five eyes treated with a newly developed solid-state laser system (AquariuZ) in three patients. Patients underwent preoperative examination, including corneal topo-and tomography, aberrometry, and confocal microscopy. All patients received a femtosecond LASIK with the Ziemer LDV Z8, a refractive treatment with the AquariuZ solid-state ablation laser, and were then followed up for a period of up to 12 months. The applied aspheric optimized profiles did not induce higher-order aberrations nor spherical aberration in any of these operated subjects. No eye lost BCVA lines throughout the duration of the follow-up. Six months after surgery, the safety index of patient 1 was 5, and for patients 2 and 3, it equaled 1. Confocal laser microscopy imaging findings were comparable to those seen typically for excimer lasers. The obtained results are encouraging and confirm that the new solid-state laser system is safe.

13.
Angew Chem Int Ed Engl ; 61(48): e202210422, 2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36220783

RESUMEN

Organic molecules which can undergo excited-state intramolecular proton transfer (ESIPT) process have been considered as ideal gain materials for near-infrared organic lasers owing to their effective four-level systems. However, extending lasing wavelength beyond 800 nm with present ESIPT-active gain materials is still in challenge. Herein, we established a molecular design strategy that operates via extending the π-conjugated system of the ESIPT parent core to enhance the cascaded double ESIPT process and thus to achieve the red-shifted six-level system lasing. Concretely, a model molecule with 1,9-dihydroxyanthracene as the ESIPT parent core was designed and synthesized, which was proved to undergo twice cascaded ESIPT processes while the 1,8-dihydroxynaphthalene-based analogue can only undergo once ESIPT process based on DFT calculations and ultrafast dynamics analyses. Finally, a six-level system lasing toward 900 nm was achieved with a low threshold of 27.4 µJ cm-2 .

14.
J Dent ; 126: 104309, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36162639

RESUMEN

OBJECTIVE: To study the effects of a 445 nm diode laser (L) and silver diamine fluoride (F) on preventing enamel demineralisation and inhibiting cariogenic bacteria. METHODS: Thirty-three enamel slices were sectioned each into four blocks for four groups to receive L with F (LF), F, L and Water (W, control). Ten blocks from each group were used to evaluate demineralisation. Surface morphology, lesion depth and nanohardness of the blocks after pH-cycling were studied by scanning electron microscopy (SEM), nanohardness test, and micro-computed tomography, respectively. Twenty-three blocks per group were used for biofilm assessment. Morphology, viability, and growth kinetics of the Streptococcus mutans biofilm were assessed by SEM, confocal laser scanning microscopy, and the counting of colony-forming units (CFUs), respectively. RESULTS: SEM images of LF-treated enamel showed an intact surface compared with other groups. Nanohardness (GPa) for LF, F, L and W were 1.43±0.17, 1.01±0.11, 1.04±0.13 and 0.73±0.14, respectively (p < 0.001; LF>F, L>W). Their lesion depths (µm) were 46±8, 52±6, 88±13 and 111±9, respectively (p < 0.001; LF, F<L<W). SEM showed few bacteria for LF and F compared with other groups. Their dead-live ratio were 1.67±0.13, 1.60±0.15, 0.39±0.05 and 0.32±0.05, respectively (p < 0.001; LF, F>L>W). Log CFUs for LF, F, L and W were 4.2±0.3, 4.5±0.2, 7.9±0.3 and 9.4±0.2, respectively (p < 0.05; LF<F<L<W). Two-way ANOVA analysis revealed an interaction effect on nanohardness and Log CFUs between the laser irradiation and SDF treatment (p < 0.001). CONCLUSION: This study showed a superior caries preventive effect of a combined treatment of the diode laser and SDF. Because diode laser and SDF are affordable and readily available, clinicians can provide this treatment to their patients for caries prevention. CLINICAL SIGNIFICANCE STATEMENT: Diode lasers are handy, afforable and readily avaliable to clinicians. This study provides information of use of 445 nm diode laser for caries prevetion. The laser irradiation hopefully can be added before conventional topical SDF application.


Asunto(s)
Caries Dental , Láseres de Semiconductores , Humanos , Láseres de Semiconductores/uso terapéutico , Microtomografía por Rayos X , Esmalte Dental , Caries Dental/prevención & control , Caries Dental/tratamiento farmacológico , Streptococcus mutans , Agua
15.
Materials (Basel) ; 15(15)2022 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-35955211

RESUMEN

Two different mid-infrared (mid-IR) solid-state crystalline laser active media of Cr2+, Fe2+:Zn1-xMnxSe and Cr2+, Fe2+:Zn1-xMgxSe with similar amounts of manganese or magnesium ions of x ≈ 0.3 were investigated at cryogenic temperatures for three different excitation wavelengths: Q-switched Er:YLF laser at the wavelength of 1.73 µm, Q-switched Er:YAG laser at 2.94 µm, and the gain-switched Fe:ZnSe laser operated at a liquid nitrogen temperature of 78 K at ∼4.05 µm. The temperature dependence of spectral and laser characteristics was measured. Depending on the excitation wavelength and the selected output coupler, both laser systems were able to generate radiation by Cr2+ or by Fe2+ ions under direct excitation or indirectly by the Cr2+→ Fe2+ energy transfer mechanism. Laser generation of Fe2+ ions in Cr2+, Fe2+:Zn1-xMnxSe and Cr2+, Fe2+:Zn1-xMgxSe (x ≈ 0.3) crystals at the wavelengths of ∼4.4 and ∼4.8 µm at a temperature of 78 K was achieved, respectively. The excitation of Fe2+ ions in both samples by direct 2.94 µm as well as ∼4.05 µm radiation or indirectly via the Cr2+→ Fe2+ ions' energy transfer-based mechanism by 1.73 µm radiation was demonstrated. Based on the obtained results, the possibility of developing novel coherent laser systems in mid-IR regions (∼2.3-2.5 and ∼4.4-4.9 µm) based on AIIBVI matrices was presented.

16.
J Fluoresc ; 32(4): 1509-1516, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35522344

RESUMEN

Optical and photophysical properties of 6-substituted-1,2,4-Triazine fluorescent derivative dye doped in silicate based sol-gel, homopolymer of methyl methacrylate (PMMA), and copolymer (MMA/diethylene glycol dimethacrylate) (DEGDMA) were investigated. The pores of different hosts and caging of the dye were found to effect on the parameters such as molar absorptivity, cross sections of singlet-singlet electronic absorption and emission spectra, excited state lifetime, quantum yield of fluorescence. The dipole moment of electronic transition, the length of attenuation and oscillator strength of electronic transition from So → S1 have been calculated. The dye was pumped with different powers using 3rd harmonic Nd: YAG laser of 355 nm and pulse duration 8 ns, with repetition rate 10 Hz. Good photo stability for dye was attained. After 55,000 pumping pulses of (10 mJ/pulse), the photo-stabilities were decreased to 53%, 48%, and 45% of the initial ASE of dye in sol gel, PMMA, and Co-polymer respectively. The dye in sol-gel matrix showed improvement of photo stability compared with those in organic polymeric matrices.

17.
Adv Sci (Weinh) ; 9(16): e2200525, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35344285

RESUMEN

Thermally activated delayed fluorescent (TADF) materials have attracted increasing attention because of their ability to harvest triplet excitons via a reverse intersystem crossing process. TADF gain materials that can recycle triplet excitons for stimulated emission are considered for solving the triplet accumulation problem in electrically pumped organic solid-state lasers (OSSLs). In this mini review, recent progress in TADF gain materials is summarized, and design principles are extracted from existing reports. The construction methods of resonators based on TADF gain materials are also introduced, and the challenges and perspectives for the future development of TADF gain materials are presented. It is hoped that this review will aid the advances in TADF gain materials and thus promote the development of electrically pumped OSSLs.

18.
Molecules ; 27(3)2022 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-35164022

RESUMEN

We report the surface morphology and the nonlinear absorption characteristics of MXene VCrC nanosheets prepared by the liquid-phase exfoliation method. The self-made MXene VCrC was applied as a saturable absorber in the Tm:YAP laser experiments, performing excellent Q-switching optical modulation characteristics in infrared range. With this absorber, a stable passively Q-switched 2 µm laser was achieved. Under an incident pump power of 3.52 W, a maximum output power of 280 mW was obtained with a T = 3% output coupler at a repetition frequency of 49 kHz. The corresponding pulse energy and peak power were 5.7 µJ and 6.6 W, respectively. The shortest pulse duration was 658 ns at the repetition rate of 63 kHz with a T = 1% output coupler.

19.
Biosens Bioelectron ; 197: 113816, 2022 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-34814031

RESUMEN

Single-mode organic solid-state lasers with direct emission into an optical waveguide are attractive candidates for cost-efficient coherent light sources employed in photonic lab-on-a-chip biosensors. Here, we present a combination of a dye-doped organic solid-state distributed feedback laser with a highly sensitive optical waveguide Mach-Zehnder interferometer on a silicon nitride photonic platform. This organic-hybrid laser allows for optical pumping with a laser diode in an alignment tolerant manner, which facilitates applications in point-of-care diagnostics. The sensitivity to bulk refractive index changes and the concentration dependent binding of streptavidin on a polyethyleneimine-biotin functionalized surface was studied to demonstrate the practicability of this cost-efficient coherent light source for optical waveguide biosensors.


Asunto(s)
Técnicas Biosensibles , Láseres de Estado Sólido , Interferometría , Compuestos de Silicona
20.
Micromachines (Basel) ; 12(11)2021 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-34832837

RESUMEN

High-power all-solid-state single-frequency continuous-wave (CW) lasers have been applied in basic research such as atomic physics, precision measurement, radar and laser guidance, as well as defense and military fields owing to their intrinsic advantages of high beam quality, low noise, narrow linewidth, and high coherence. With the rapid developments of sciences and technologies, the traditional single-frequency lasers cannot meet the development needs of emerging science and technology such as quantum technology, quantum measurement and quantum optics. After long-term efforts and technical research, a novel theory and technology was proposed and developed for improving the whole performance of high-power all-solid-state single-frequency CW lasers, which was implemented by actively introducing a nonlinear optical loss and controlling the stimulated emission rate (SER) in the laser resonator. As a result, the output power, power and frequency stabilities, tuning range and intensity noise of the single-frequency lasers were effectively enhanced.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...