Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros











Intervalo de año de publicación
1.
Univ. psychol ; 16(1): 3-11, Jan.-Mar. 2017. graf
Artículo en Inglés | LILACS, COLNAL | ID: biblio-904611

RESUMEN

ABSTRACT The present study aimed to determine the optimum response time (RT) needed to identify images of everyday objects when filtered using different spatial frequency bands. Subjects were randomly presented with different images of familiar objects that were both serialized and progressive in their spatial frequencies. The time needed to recognize them was then measured. The results showed that the optimum RT for identifying an image filtered in different spatial frequency bands was approximately 2000 ms of exposure. Specifically, stimuli presented using spatial frequency bands with Gaussian filters of variance V26-V32, which were familiar and of medium size to the viewer, were recognized in a mean time of 2126 ms.


RESUMEN El presente estudio tiene como objetivo determinar el tiempo de respuesta óptimo (RT) necesario para identificar imágenes de objetos cotidianos cuando se filtran utilizando diferentes bandas de frecuencias espaciales. A los sujetos se les presentaba aleatoriamente diferentes imágenes de objetos familiares cuyas bandas de frecuencia eran progresivamente serializadas. Se midió el tiempo necesario para reconocerlos. Los resultados mostraron que la RT óptima para identificar una imagen filtrada en diferentes bandas de frecuencias espaciales fue de aproximadamente 2000 ms de exposición. En concreto, los estímulos presentados utilizando bandas de frecuencias espaciales con filtros gaussianos de varianza V26-V32, que eran familiares y de tamaño medio para el espectador, se reconocieron en un tiempo medio de 2126 ms.


Asunto(s)
Tiempo de Reacción , Percepción Visual
2.
Front Psychol ; 4: 213, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23637687

RESUMEN

Spatial frequency (SF) components encode a portion of the affective value expressed in face images. The aim of this study was to estimate the relative weight of specific frequency spectrum bandwidth on the discrimination of anger and fear facial expressions. The general paradigm was a classification of the expression of faces morphed at varying proportions between anger and fear images in which SF adaptation and SF subtraction are expected to shift classification of facial emotion. A series of three experiments was conducted. In Experiment 1 subjects classified morphed face images that were unfiltered or filtered to remove either low (<8 cycles/face), middle (12-28 cycles/face), or high (>32 cycles/face) SF components. In Experiment 2 subjects were adapted to unfiltered or filtered prototypical (non-morphed) fear face images and subsequently classified morphed face images. In Experiment 3 subjects were adapted to unfiltered or filtered prototypical fear face images with the phase component randomized before classifying morphed face images. Removing mid frequency components from the target images shifted classification toward fear. The same shift was observed under adaptation condition to unfiltered and low- and middle-range filtered fear images. However, when the phase spectrum of the same adaptation stimuli was randomized, no adaptation effect was observed. These results suggest that medium SF components support the perception of fear more than anger at both low and high level of processing. They also suggest that the effect at high-level processing stage is related more to high-level featural and/or configural information than to the low-level frequency spectrum.

3.
Front Hum Neurosci ; 7: 92, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23576967

RESUMEN

Hemispheric specialization for spatial frequency processing was investigated by measuring the contrast sensitivity curves of sine-wave gratings in 30 left or right brain-damaged patients using different spatial frequencies compared with healthy participants. The results showed that left brain-damaged patients were selectively impaired in processing high frequencies, whereas right brain-damaged patients were more impaired in the processing low frequencies, regardless of the presence of visuo-spatial neglect. These visual processing results can be interpreted in terms of spatial frequency discrimination, with both hemispheres participating in this process in different ways.

4.
Estud. psicol. (Natal) ; 17(1): 115-120, jan.-abr. 2012. ilus
Artículo en Portugués | Index Psicología - Revistas | ID: psi-52222

RESUMEN

O objetivo foi medir a sensibilidade ao contraste, SC, visual de grades senoidais circulares concêntricas com frequências espaciais de 0,25; 4 e 8 cpg, ciclos por grau de ângulo visual, em adultos saudáveis e com depressão maior. Foram estimadas a SC de 20 participantes, 10 saudáveis e 10 participantes com depressão maior, utilizando o método psicofísico da escolha forçada e luminância média de 0,7 cd/m². Todos os participantes apresentavam acuidade visual normal ou corrigida e estavam livres de doenças identificáveis. Os resultados mostraram que a SC visual máxima ocorreu na faixa de 0,25 cpg para os dois grupos. Os resultados demonstraram ainda que a SC visual dos participantes com depressão maior foi mais baixa do que a dos participantes saudáveis (p < 0,05), pois os participantes com transtorno precisaram de mais contraste para detectar as frequências espaciais testadas. Estes resultados sugerem alterações na percepção visual relacionadas à depressão maior.(AU)


The aim of this study was to measure visual contrast sensitivity, CS, for concentric circular sine-wave gratings with spatial frequencies of 0.25, 4 and 8 cpd, cycles per degree of visual angle, in adults without and with major depression disorder. We measured the visual CS for 20 participants, ten without and ten with major depression disorder medicated, using a temporal two-alternative forced-choice psychophysical method with mean luminance of 0.7 cd/m². All volunteers were free from identifiable ocular disease and had normal acuity. The results showed maximum contrast sensitivity to spatial frequency occurred in the range of 0.25 cpd for both groups. The results also showed that the visual CS for major depression was lower than those of adults without depression (p < 0.05). These results showed alterations in the visual perception related the major depression.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Percepción Visual , Sensibilidad de Contraste , Depresión/patología , Neurociencias
5.
Estud. psicol. (Natal) ; 17(1): 115-120, Jan.-Apr. 2012. ilus
Artículo en Portugués | LILACS | ID: lil-643700

RESUMEN

O objetivo foi medir a sensibilidade ao contraste, SC, visual de grades senoidais circulares concêntricas com frequências espaciais de 0,25; 4 e 8 cpg, ciclos por grau de ângulo visual, em adultos saudáveis e com depressão maior. Foram estimadas a SC de 20 participantes, 10 saudáveis e 10 participantes com depressão maior, utilizando o método psicofísico da escolha forçada e luminância média de 0,7 cd/m². Todos os participantes apresentavam acuidade visual normal ou corrigida e estavam livres de doenças identificáveis. Os resultados mostraram que a SC visual máxima ocorreu na faixa de 0,25 cpg para os dois grupos. Os resultados demonstraram ainda que a SC visual dos participantes com depressão maior foi mais baixa do que a dos participantes saudáveis (p < 0,05), pois os participantes com transtorno precisaram de mais contraste para detectar as frequências espaciais testadas. Estes resultados sugerem alterações na percepção visual relacionadas à depressão maior.


The aim of this study was to measure visual contrast sensitivity, CS, for concentric circular sine-wave gratings with spatial frequencies of 0.25, 4 and 8 cpd, cycles per degree of visual angle, in adults without and with major depression disorder. We measured the visual CS for 20 participants, ten without and ten with major depression disorder medicated, using a temporal two-alternative forced-choice psychophysical method with mean luminance of 0.7 cd/m². All volunteers were free from identifiable ocular disease and had normal acuity. The results showed maximum contrast sensitivity to spatial frequency occurred in the range of 0.25 cpd for both groups. The results also showed that the visual CS for major depression was lower than those of adults without depression (p < 0.05). These results showed alterations in the visual perception related the major depression.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Sensibilidad de Contraste , Depresión/patología , Neurociencias , Percepción Visual
6.
Psicol. teor. pesqui ; Psicol. (Univ. Brasília, Online);25(4): 581-587, out.-dez. 2009. ilus
Artículo en Portugués | Index Psicología - Revistas | ID: psi-54519

RESUMEN

O objetivo deste estudo foi comparar curvas de sensibilidade ao contraste para estímulos radiais (FSCr) e grades senoidais (FSC) de 0,25, 0,5, 1 e 2 cpg em crianças de 6 a 13 anos. Foram mensurados limiares de contraste para 40 crianças, utilizando o método psicofísico da escolha forçada e níveis baixos de luminância. Todas estavam livres de doenças oculares e tinham acuidade visual normal. Os resultados mostraram que a sensibilidade das crianças foi maior para grades senoidais (FSC) do que para estímulos radiais (FSCr). Esses resultados sugerem que esses estímulos podem ser processados por áreas visuais distintas.(AU)


The aim of this work was to compare contrast sensitivity curves for radial (rCSF) and sine-wave gratings (CSF) stimuli of 0.25, 0.5, 1 and 2 cpd in 6 to 13 year-old-children. It was measured the contrast thresholds of 40 children using the psychophysical forced-choice method and low luminance levels. All children were free of identifiable ocular diseases and had normal acuity. The results showed that contrast sensitivity of the children was higher for spatial frequencies (CSF) than radial frequencies (rCSF). The results suggest that these stimuli can be processed by different visual cortical areas.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Niño , Sensibilidad de Contraste , Percepción Visual
7.
Psychol. Neurosci. (impr.) ; 2(2): 163-177, Dec. 2009. graf
Artículo en Inglés | Index Psicología - Revistas | ID: psi-46722

RESUMEN

We introduce a new VEP paradigm - the Jitter Spatial Frequency (JSF) Sweep VEP - that permits efficient mapping of the spatiotemporal tuning of the developmental motion asymmetry (DMA). Vertical sinewave gratings undergoing 90º horizontal oscillatory displacements (6 or 10 Hz) were presented while their SF was swept over 2 to 5 octaves during each VEP trial. JSF sweep VEPs were recorded from 28 infants (8-43 weeks), and symmetric (second-harmonic, F2) and asymmetric (F1) components of the VEP were measured. JSF sweeps can provide four useful estimates: (1,2) the high-SF cutoff of F1 and F2 responses estimates the spatial resolution of direction-selective (DS) and non-DS mechanisms, respectively; (3) the low-SF cutoff for F1 estimate the SF-boundary between mature (F1 absent) and immature (F1 present) DS mechanisms; and (4) the F1 high-SF cutoff estimates the lower velocity limit of cortical DS cells. For 6 Hz, the low-SF F1 cutoffs increased two times faster than traditional (contrast-reversal) VEP grating acuity (0.5 vs ~0.25 octaves/month), and twice that of the high-SF F1 and F2 cutoffs. This implies that no single mechanism can account for the DMA at both low and high SFs. At 10 Hz, the DMA exhibited no significant development, consistent with slower maturation of DS mechanisms at higher ST frequencies. The F2 high-SF cutoffs were higher than F1 at both 6 and 10 Hz, suggesting higher spatial resolution for non-DS (pattern) vs DS (motion) mechanisms. Finally, the lower velocity limit of the DS mechanisms decreased from ~2 deg/sec at 8 weeks, to 0.75 deg/sec at 33 weeks, similar to analogous limits for direction-of-motion identification in adults (~0.5 - 1 deg/sec), and close to prior VEP estimates in infants (0.6 deg/sec).(AU)


Asunto(s)
Humanos , Lactante , Desarrollo Infantil , Potenciales Evocados Visuales/fisiología , Percepción Visual
8.
Psychol. neurosci. (Impr.) ; 2(2): 163-177, Dec. 2009. graf
Artículo en Inglés | LILACS | ID: lil-574094

RESUMEN

We introduce a new VEP paradigm - the Jitter Spatial Frequency (JSF) Sweep VEP - that permits efficient mapping of the spatiotemporal tuning of the developmental motion asymmetry (DMA). Vertical sinewave gratings undergoing 90º horizontal oscillatory displacements (6 or 10 Hz) were presented while their SF was swept over 2 to 5 octaves during each VEP trial. JSF sweep VEPs were recorded from 28 infants (8-43 weeks), and symmetric (second-harmonic, F2) and asymmetric (F1) components of the VEP were measured. JSF sweeps can provide four useful estimates: (1,2) the high-SF cutoff of F1 and F2 responses estimates the spatial resolution of direction-selective (DS) and non-DS mechanisms, respectively; (3) the low-SF cutoff for F1 estimate the SF-boundary between mature (F1 absent) and immature (F1 present) DS mechanisms; and (4) the F1 high-SF cutoff estimates the lower velocity limit of cortical DS cells. For 6 Hz, the low-SF F1 cutoffs increased two times faster than traditional (contrast-reversal) VEP grating acuity (0.5 vs ~0.25 octaves/month), and twice that of the high-SF F1 and F2 cutoffs. This implies that no single mechanism can account for the DMA at both low and high SFs. At 10 Hz, the DMA exhibited no significant development, consistent with slower maturation of DS mechanisms at higher ST frequencies. The F2 high-SF cutoffs were higher than F1 at both 6 and 10 Hz, suggesting higher spatial resolution for non-DS (pattern) vs DS (motion) mechanisms. Finally, the lower velocity limit of the DS mechanisms decreased from ~2 deg/sec at 8 weeks, to 0.75 deg/sec at 33 weeks, similar to analogous limits for direction-of-motion identification in adults (~0.5 - 1 deg/sec), and close to prior VEP estimates in infants (0.6 deg/sec).


Asunto(s)
Humanos , Lactante , Desarrollo Infantil , Potenciales Evocados Visuales/fisiología , Percepción Visual
9.
Psicol. teor. pesqui ; Psicol. (Univ. Brasília, Online);25(4): 581-587, out.-dez. 2009. ilus
Artículo en Portugués | LILACS | ID: lil-540959

RESUMEN

O objetivo deste estudo foi comparar curvas de sensibilidade ao contraste para estímulos radiais (FSCr) e grades senoidais (FSC) de 0,25, 0,5, 1 e 2 cpg em crianças de 6 a 13 anos. Foram mensurados limiares de contraste para 40 crianças, utilizando o método psicofísico da escolha forçada e níveis baixos de luminância. Todas estavam livres de doenças oculares e tinham acuidade visual normal. Os resultados mostraram que a sensibilidade das crianças foi maior para grades senoidais (FSC) do que para estímulos radiais (FSCr). Esses resultados sugerem que esses estímulos podem ser processados por áreas visuais distintas.


The aim of this work was to compare contrast sensitivity curves for radial (rCSF) and sine-wave gratings (CSF) stimuli of 0.25, 0.5, 1 and 2 cpd in 6 to 13 year-old-children. It was measured the contrast thresholds of 40 children using the psychophysical forced-choice method and low luminance levels. All children were free of identifiable ocular diseases and had normal acuity. The results showed that contrast sensitivity of the children was higher for spatial frequencies (CSF) than radial frequencies (rCSF). The results suggest that these stimuli can be processed by different visual cortical areas.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Percepción Visual , Sensibilidad de Contraste
10.
Psychol. neurosci. (Impr.) ; 2(1): 11-15, June 2009. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-567683

RESUMEN

The aim of this study was to determine the contrast sensitivity curves of sine-wave gratings with spatial frequencies of 0.25, 1.0, 2.0 and 8.0 cycles per degree (cpd) of visual angle in 16 female subjects aged 7 to 9 years old, eight well-nourished and eight with acute protein-energy malnutrition (PEM). All participants had normal visual acuity and were free of identifiable ocular illness. Contrast threshold was measured using a temporal two-alternative forced-choice psychophysical method, at a distance of 150 cm of the stimuli, binocularly, with mean luminance of 40.1 cd/m2. We detected a general decline in contrast sensitivity for children with acute malnutrition at all spatial frequencies compared to well-nourished children. The malnourished group needed in average 1.37 times more contrast to detect the stimulus in comparison with the well-nourished one. Differences between the groups were statistically significant at all spatial frequencies (p < .001). These results suggest that acute PEM changes the visual perception for sine-wave gratings.


Asunto(s)
Humanos , Femenino , Niño , Trastornos de la Nutrición del Niño , Sensibilidad de Contraste , Percepción Visual
11.
Psico (Porto Alegre) ; 40(2): 227-234, abr.-jun. 2009.
Artículo en Portugués | LILACS | ID: lil-539637

RESUMEN

O objetivo deste estudo foi medir e comparar as curvas de sensibilidade ao contraste mesópicas para estímulos radiais (FSCr) e grades senoidais (FSC) de 0,25; 0,5; 1 e 2 cpg em crianças surdas de 7 a 12 anos. Mensuramos limiares de contraste para 10 crianças, utilizando o método psicofísico da escolha forçada e luminância média de 0,7 cd/m2. Todos os participantes estavam livres de doenças oculares e apresentavam acuidade visual normal. Os resultados mostraram que a sensibilidade das crianças surdas foi maior para grades senoidais (FSC) do que para estímulos radiais (FSCr). Estes resultados sugerem que os dois estímulos podem ser processados por áreas visuais corticais distintas.


The aim of this work was to measure and compare mesopic contrast sensitivity curves for radial (rCSF) and sine-wave gratings (CSF) stimuli of 0.25, 0.5, 1 and 2 cpd in deaf children between the ages of 7 to 12 years. We measured the contrast thresholds of 10 children using the psychophysical forced-choice method and mean luminance of 0.7 cd/m2. All participants were free of ocular diseases and had normal acuity. The results showed that contrast sensitivity of the deaf children was higher for sine-wave gratings (CSF) than radial stimuli (rCSF). These results suggest that these two stimuli can be processed by different visual cortical areas.


El objetivo de este estudio fue medir y comparar las curvas de sensibilidad al contraste mesópicas para estímulos radiales (FSCr) y rejillas sinusoidales (FSC) de 0,25; 0,5; 1 y 2 cpg en niños sordos de 7 a 12 años. Medimos los umbrales de contraste en 10 niños, con el método psicofísico de la elección forzada y la luminancia media de 0,7 cd/m2. Todos los participantes estaban libres de enfermedades oculares y presentaban acuidad visual normal. Los resultados mostraron que la sensibilidad de los niños sordos fue mayor para frecuencias espaciales (FSC) que para los estímulos radiales (FSCr). Estos resultados sugieren que los estímulos pueden ser procesados en distintas areas corticales visuales.


Asunto(s)
Humanos , Masculino , Niño , Sordera , Percepción Visual
12.
Psicol. reflex. crit ; 22(2): 230-235, 2009. ilus
Artículo en Portugués | LILACS | ID: lil-527499

RESUMEN

O objetivo deste trabalho foi comparar a sensibilidade ao contraste (FSC) de crianças surdas e crianças ouvintes para freqüências espaciais de 0,25 a 2,0 cpg (ciclos por grau de ângulo visual) em nível de luminância mesópica (0,7 cd/m²), utilizando o método psicofísico da escolha forçada. Vinte crianças (7-12 anos) participaram desta pesquisa, dez com surdez pré-lingual e dez ouvintes. Todos os participantes apresentavam acuidade visual normal ou corrigida. A ANOVA mostrou diferença significante entre os grupos [F(1, 238) = 15,487; p < 0,001], porém a análise com o teste post-hoc Tukey HSD não revelou diferença significante na comparação freqüência a freqüência entre os dois grupos (p > 0,05). Os resultados sugerem alterações na FSC para estímulos de grade senoidal das crianças surdas em níveis de luminância mesópica.


The aim of this study was to compare the contrast sensitivity (CSF) of deaf children and hearing children to spatial frequency of 0.25 to 2.0 cpd (cycles per degree of visual angle) at mesopic luminance level (0.7 cd/m²), using the psychophysical forced-choice method. Twenty children (7-12 years old) participated in this research, ten with prelingual deafness and ten with normal hearing. All participants had normal or corrected visual acuity. The ANOVA showed significant difference between the two groups [F(1, 238) = 15.487; p < 0.001], but the post-hoc Tukey HSD test analysis did not reveal significant difference in frequency to frequency comparison between the two groups (p > 0.05). The results suggest alterations in CSF to sine-wave gratings stimuli of deaf children at mesopic luminance level.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Sensibilidad de Contraste , Personas con Deficiencia Auditiva/psicología , Percepción Visual
13.
Psicol. teor. pesqui ; Psicol. (Univ. Brasília, Online);24(4): 515-518, out.-dez. 2008. ilus, graf
Artículo en Portugués | LILACS | ID: lil-508897

RESUMEN

O objetivo deste trabalho foi caracterizar a função de sensibilidade ao contraste (FSC) para freqüências espaciais de 0,25, 1,0 e 4,0 cpg (ciclos por grau de ângulo visual) na ausência (Grupo Controle-GC) e após a ingestão moderada de álcool (Grupo Experimental-GE). Para tanto, foi utilizado o método psicofísico da escolha forçada. Participaram do estudo quatro mulheres, de 21 a 30 anos, com acuidade visual normal ou corrigida. Os resultados mostraram diferenças significativas entre os grupos na freqüência de 4,0 cpg (p = 0,039), sendo o GE mais sensível ao contraste do que o GC. Estes resultados sugerem alterações na FSC relacionadas à ingestão moderada de álcool.


The purpose of this paper was to characterize the contrast sensitivity function (CSF) for spatial frequencies equal to 0.25, 1.0 and 4.0 cpd (cycles per degree) in the absence (Control Group-CG) and after moderate alcohol ingestion (Experimental Group-EG). For such, the forced choice psychophysical method was used. The participants were four 21 to 30 year-old-women with normal or corrected visual acuity. The results showed a significant difference between groups at the spatial frequency of 4.0 cpd (p= 0.039), such that the EG was more sensitive to contrast than the CG. These results suggest alcohol-related alterations in the CSF.


Asunto(s)
Trastornos Relacionados con Alcohol/psicología
14.
Psicol. teor. pesqui ; Psicol. (Univ. Brasília, Online);23(3): 319-326, jul.-set. 2007. ilus, graf
Artículo en Portugués | LILACS | ID: lil-470988

RESUMEN

O objetivo deste estudo foi comparar curvas de sensibilidade ao contraste para estímulos radiais (FSCr) e grades senoidais (FSC) de 0,25, 0,5, 1 e 2 cpg em adultos e idosos. Mensuramos limiares de contraste para seis adultos jovens e seis idosos utilizando o método psicofísico da escolha forçada. Todos estavam livres de doenças oculares e tinham acuidade visual normal. Os idosos apresentaram prejuízos na FSC e FSCr se comparados aos adultos jovens. A sensibilidade dos adultos e idosos foi maior para grades senoidais (FSC) do que para estímulos radiais (FSCr). Esses resultados sugerem que esses estímulos podem ser processados por áreas visuais distintas.


Asunto(s)
Adulto , Persona de Mediana Edad , Sensibilidad de Contraste , Percepción Visual , Envejecimiento/psicología
15.
Paidéia (Ribeiräo Preto) ; 16(34): 225-228, maio-ago. 2006. ilus, graf
Artículo en Portugués | LILACS | ID: lil-466838

RESUMEN

Em termos gerais, a FSC tem sido usada para caracterizar o desenvolvimento da percepção visual da forma de crianças. O objetivo do presente estudo foi mensurar e comparar curvas de sensibilidade ao contraste para estímulos radiais (FSCr) e grades senoidais (FSC) em crianças pré-escolares com o método psicofísico da escolha forçada- senoidais de 0,25; 0,5; 1 e 2 cpg em crianças pré-escolares (4 e 5 anos) e adultos jovens com o método psicofísico da escolha forçada. Participaram 15 voluntários com a acuidade visual normal ou corrigida distribuídos igualmente nas três faixas etárias. Os resultados mostraram que a sensibilidade melhora com o desenvolvimento e que a sensibilidade de todos os participantes foi maior para as grades senoidais do que para as freqüências radiais. Estes resultados sugerem que os estímulos radiais e as grades senoidais são processados por áreas visuais diferentes.


In general the FSC is used to characterise the development of the visual perception of material by children. The aim of the present work was to mensure and compare contrast the sensitivity curves to differ then of the radical stimuly (FSCr) and sine-wave gratings (FSC) in pré-school children, usind the psychophysical method of choice-forced for radial and sine-wave gratings stimuli of 0.25; 0.5; 1 and 2 cpd in 4-5 yearold preschool children and young adults using the psychophysical forced-choice staircase method. Fifteen volunteers with corrected-to-normal visual acuity, five in each age range, participated in the experiments. The results showed that the sensitivity improves with the development and that in for all participants the sensitivity was higher for sine-wave gratings than the radial frequencies. These results suggest that the radial and the sine-wave gratings stimuli are processed by different visual areas.


Asunto(s)
Preescolar , Niño , Adulto , Sensibilidad de Contraste
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA