Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 290
Filtrar
1.
Comput Biol Med ; 179: 108824, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38981213

RESUMEN

Functional and esthetic results require accurate implant placement. We aimed to develop a predictive method for assessing guide layout and error on implant accuracy. A mathematical model for position error analysis was constructed based on triangular mesh data. This model examines the relationship between the spatial shifts of multiple surfaces and the spatial shifts of specific points. It involves encasing these surfaces in a cuboid bounding box and expressing them in a local coordinate system. The influence of positioning surface error and layout of surgical guide were researched with a simulation test. The result shows that error in the implant site position is directly related to the error in the guide locating surface under the same layout. When the guide locating surface layout varies, as the length, width, and height of the minimum cuboid envelope increase, the maximum deviation in the implant site position decreases.

3.
J Dent ; : 105226, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38971459

RESUMEN

OBJECTIVES: The aim of this study was to assess the accuracy of surgical guides printed using four different manufacturer workflows. METHODS: Forty-eight surgical guides (BlueSky Plan, BlueSky Bio) were produced using four different printers, with strict adherence to each manufacturer's instructions. The printers used were three DLP printers (SolFlex170 (VC), Nextdent5100 (ND), D30+Rapidshape (RS)) and one SLA printer (Formlabs3B+ (FL)). The study evaluated the trueness and precision of the overall surface, the region of interest (RoI) (occlusal and guide zone), the repeatability in several batches, and the guide hole's diameter and xyz axes. The printed guides were digitized and compared with the CAD design control specimen (Control X, Geomagic). Descriptive statistics and Kruskal-Wallis tests with post-hoc Mann-Whitney tests were performed (α=0.05). RESULTS: Statistical analysis revealed differences in trueness and precision were found between groups in the overall zone and RoI (p=0.00). The ND group demonstrated the highest repeatability. Only the RS group exhibited a comparable guide hole diameter to the master specimen (5.27±2.12 mm; p=0.104). No statistical differences were observed between groups in the x and z axes. However, in the y-axis, the VC group displayed statistically significant differences (p=0.01). CONCLUSIONS: The results showed that the DLP groups had better overall accuracy, while the SLA group had the best results in the RoI. The manufacturer's workflows demonstrated a high reproducibility between batches in the RoI. The RS group had values most similar values to the guide hole diameter of the master specimen, with minimal deviations in guide hole orientation. CLINICAL SIGNIFICANCE: Implant position is a crucial factor in the long-term success, and it can be affected by the accuracy of the 3D printed surgical guide. Therefore, it is critical to analyze the final dimensions and the direction of the guide hole using available printing technologies.

4.
Int J Implant Dent ; 10(1): 36, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39012381

RESUMEN

PURPOSE: This study aims to evaluate the amount of distortion using computer-guided implant surgery with 3D printed surgical guides in limited edentulous spaces. MATERIALS AND METHODS: 25 bone level self-tapping implants (Straumann® BL and BLT) were randomly inserted in either distal or intercalary posterior mandibular edentulism using a fully digital protocol and 3D printed surgical guides. Amount of inaccuracy was evaluated after superimposing the 3 coordinates of virtually planned and final implant images, which were obtained using intra-oral scans and scan bodies. Four evaluation parameters were considered: origo-displacement, error depth, apical displacement and angle between the planned and the placed implant. RESULTS: The average of distortion was 0.71 mm for the origo-displacement, 0.36 mm for the error depth, 0.52 mm for the horizontal displacement and 3.34º for the error angle. CONCLUSION: The major reason of exclusion was CBCT artifacts. Results of this study were aligned with the results of previous studies concerning partially edentulous spaces. CAD/CAM manufacturing process did not result in significant distortion whilst the biggest part of distortions originated from the surgical process. The learning curve in computer-guided implant surgery presented an important source of inaccuracy.


Asunto(s)
Arcada Parcialmente Edéntula , Cirugía Asistida por Computador , Humanos , Cirugía Asistida por Computador/métodos , Estudios Prospectivos , Arcada Parcialmente Edéntula/cirugía , Arcada Parcialmente Edéntula/diagnóstico por imagen , Implantación Dental Endoósea/métodos , Implantación Dental Endoósea/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Impresión Tridimensional , Implantes Dentales , Tomografía Computarizada de Haz Cónico
5.
Int J Implant Dent ; 10(1): 29, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38839621

RESUMEN

PURPOSE: This study evaluated the implant stability, volumetric changes, and patient-reported outcome measures (PROMs) of hydroxyapatite (HA) nano-coated sandblasted/acid-etched (SLA) implants compared to uncoated SLA implants. METHODS: Forty patients were recruited and randomly allocated to HA nano-coated SLA group (test, n = 20) and uncoated SLA group (control, n = 20) using single-blinded/block randomization. Implants were immediately placed in maxillary posterior region using a digital surgical guide. Insertion torque and implant stability quotient (ISQ) were measured at implant surgery and 1, 2, 3, and 4 months postoperatively. Intraoral scans, PROMs and soft tissue inflammation data were collected, and multivariable linear regression analysis of ISQ was performed. RESULTS: In total, 48 implants (test; n = 24, control; n = 24) in 37 patients (test; n = 19, control; n = 18) were analyzed. Despite no significant between-group difference at surgery, the test group showed higher ISQ values than the control group at 2 (76.53 ± 4.17 vs. 71.32 ± 4.79, p < 0.01), 3 (77.45 ± 4.41 vs. 73.85 ± 4.69, p < 0.05), and 4 months (79.08 ± 2.96 vs. 73.43 ± 3.52, p < 0.0001) postoperatively. There were no significant differences in linear and volumetric changes, PROMs, and soft tissue inflammation analysis between two groups. The ISQ at implant surgery was influenced by age and diabetes mellitus (DM) at the implant level and DM and predicted total bone-to-implant contact area at the patient level. CONCLUSION: HA nano-coated SLA implants promoted favorable immediate implants stability during early osseointegration phase compared to uncoated SLA implants, but displayed similar dimensional changes, PROMs, and soft tissue inflammation outcomes. TRIAL REGISTRATION: Clinical Research Information Service (CRIS), KCT0006364. Registered 21 July 2021, https://cris.nih.go.kr/cris/search/detailSearch.do?seq=24221&search_page=L .


Asunto(s)
Durapatita , Humanos , Masculino , Femenino , Persona de Mediana Edad , Método Simple Ciego , Implantes Dentales , Carga Inmediata del Implante Dental/métodos , Adulto , Materiales Biocompatibles Revestidos/química , Grabado Ácido Dental , Anciano , Medición de Resultados Informados por el Paciente , Oseointegración , Propiedades de Superficie
6.
BMC Oral Health ; 24(1): 738, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38937749

RESUMEN

BACKGROUND: The aim of this study was to evaluate the adhesion of Candida glabrata, Candida albicans, Candida krusei, Candida parapsilosis and Candida tropicalis yeasts to disk-shaped resin materials produced from resin which used in the production of surgical guide with 0, 45 and 90-degrees printing orientations by Liquid Crystal Display additive manufacturing technology. METHODS: Disk-shaped specimens were printed with surgical guide resin using the Liquid Crystal Display production technique in 3 printing orientations (0, 45 and 90-degrees). Surface roughness and contact angle values were evaluated. Real-Time PCR analysis was performed to evaluate Candida adhesion (C. glabrata, C. albicans, C. krusei, C. parapsilosis and C. tropicalis) Field emission scanning electron microscope (FESEM) images of the materials were obtained. RESULTS: Specimens oriented at 45-degrees demonstrated higher surface roughness (P < .05) and lower contact angle values than other groups. No significant difference was found in the adhesion of C. glabrata, C. albicans, and C. parapsilosis among specimens printed at 0, 45, and 90-degrees orientations (P > .05). A higher proportion of C. krusei and C. tropicalis was found in the specimens printed at orientation degrees of 45 = 90 < 0 with statistical significance. Analyzing the adhesion of all Candida species reveals no statistical disparity among the printing orientations. CONCLUSIONS: The surface roughness, contact angle, and adhesion of certain Candida species are affected by printing orientations. Hence, careful consideration of the printing orientation is crucial for fabricating products with desirable properties. In 45-degree production, roughness increases due to the layered production forming steps, whereas in 0-degree production, certain Candida species exhibit high adhesion due to the formation of porous structures. Consequently, considering these factors, it is advisable to opt for production at 90-degrees, while also considering other anticipated characteristics.


Asunto(s)
Candida , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Candida glabrata , Candida tropicalis , Candida parapsilosis , Humanos , Candida albicans , Ensayo de Materiales , Adhesión Celular , Reacción en Cadena en Tiempo Real de la Polimerasa , Impresión Tridimensional , Resinas Sintéticas , Humectabilidad
7.
Artículo en Inglés | MEDLINE | ID: mdl-38932561

RESUMEN

AIM: The aim of this study was to evaluate the accuracy of 3-dimensional (3D)-printed surgical guides for fully guided immediate implants from different manufacturers. METHODS: Eighteen 3D printed fully guided surgical guides (split into 3 groups [n = 6] according to their manufacturer: Company, Desktop, or Lab), were used to place 72 implants (n = 24) in identical maxillary models. After placement, the mean global, angular, mesiodistal, buccopalatal, and vertical deviation at the platform and apex of the placed implants, relative to their preoperatively planned positions, was calculated. RESULTS: Significant differences in global apex deviation, angular deviation, mesiodistal apex deviation, and vertical platform and apex deviation were found between the Lab and Desktop groups (p ≤ 0.007). Significant differences in mesiodistal platform and apex deviation and buccopalatal apex deviation were also found between the Company and Desktop groups (p ≤ 0.005). Finally, significant differences in buccopalatal apex deviation, and vertical platform and apex deviation were found between the Company and Lab groups (p ≤ 0.003). Mean differences between guide groups across all parameters never exceeded 0.5 mm or 1°. CONCLUSIONS: The choice of 3D printer has a significant effect on the accuracy of fully guided immediate implants. However, the clinical relevance of these differences may be considered limited.

8.
Cancers (Basel) ; 16(11)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38893279

RESUMEN

Radiologic reconstruction technology allows the wide use of three-dimensional (3D) computed tomography (CT) images in thoracic surgery. A minimally invasive surgery has become one of the standard therapies in thoracic surgery, and therefore, the need for preoperative and intraoperative simulations has increased. Three-dimensional CT images have been extensively used, and various types of software have been developed to reconstruct 3D-CT images for surgical simulation worldwide. Several software types have been commercialized and widely used by not only radiologists and technicians, but also thoracic surgeons. Three-dimensional CT images are helpful surgical guides; however, in almost all cases, they provide only static images, different from the intraoperative views. Lungs are soft and variable organs that can easily change shape by intraoperative inflation/deflation and surgical procedures. To address this issue, we have developed a novel software called the Resection Process Map (RPM), which creates variable virtual 3D images. Herein, we introduce the RPM and its development by tracking the history of 3D CT imaging in thoracic surgery. The RPM could help develop a real-time and accurate surgical navigation system for thoracic surgery.

9.
JSES Int ; 8(3): 646-653, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38707552

RESUMEN

Background: Various methods of two or three-dimensional (3D) corrective osteotomy for cubitus varus deformity have been reported. However, whether 3D correction of cubitus varus deformity is necessary is controversial because of technical difficulties and surgical complications. This study introduced 3D simulations and printing technology for corrective osteotomy against cubitus varus deformities. Moreover, recent studies on the application of these technologies were reviewed. Methods: The amount of 3D deformity was calculated based on the difference in 3D shape between the affected side and the contralateral normal side. Patient-matched instruments were created to perform the actual surgery as simulated. Further, a 3D corrective osteotomy was performed using patient-matched instruments for cubitus varus deformity in pediatric and adolescent patients. The humerus-elbow-wrist angle, tilting angle, and elbow ranges of motion were evaluated. Results: Humerus-elbow-wrist angle and tilting angle were corrected from -21° to 14° and from 30° to 43°, respectively, in the pediatric patient and from -18° to 10° and from 20° to 40°, respectively, in the adolescent patient. The elbow flexion and extension angles changed from 130° to 140° and from 20° to 10°, respectively, in the pediatric patient and from 120° to 130° and from 15° to 0°, respectively, in the adolescent patient. Conclusion: The 3D computer simulations and the use of patient-matched instruments for cubitus varus deformity are reliable and can facilitate an accurate and safe correction. These technologies can simplify the complexity of 3D surgical procedures and contribute to the standardization of treatment for cubitus varus deformity.

10.
Dent Traumatol ; 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38794910

RESUMEN

BACKGROUND/AIM: This study aims to evaluate the precision and efficacy of utilizing computer-aided design (CAD) in combination with three-dimensional printing technology for tooth transplantation. MATERIAL AND METHODS: This study analysed 50 transplanted teeth from 48 patients who underwent tooth transplantation surgery with the aid of CAD and positional guides. A consistent coordinate system was established using preoperative and postoperative cone-beam computed tomography images. Linear displacements and angular deviations were calculated by identifying key regions in both virtual designs and actual transplanted teeth. Additionally, an analysis was conducted to explore potential factors influencing these deviations. RESULTS: The mean cervical deviation, apical deviation, and angular deviation among the 50 transplanted teeth were 1.16 ± 0.57 mm, 1.80 ± 0.94 mm, and 6.82 ± 3.14°, respectively. Cervical deviation was significantly smaller than apical deviation. No significant difference in deviation was observed among different recipient socket locations, holding true for both single-root, and multi-root teeth. However, a significant difference was noted in apical deviation between single-root and multi-root teeth. Our analysis identified a correlation between apical deviation and root length, leading to the development of a prediction model: Apical deviation = 0.1390 × (root length) + 0.2791. CONCLUSIONS: The postoperative position of the donor teeth shows discrepancies compared to preoperative simulation when utilizing CAD and 3D printed templates during autotransplantation procedures. Continual refinement of preoperative design is a crucial endeavour.

11.
Int J Implant Dent ; 10(1): 27, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38819712

RESUMEN

OBJECTIVE: To address the instability in implant surgical guides, this technique proposes an alternative anchoring mechanism in the stackable metal surgical guides utilizing cone-wedge anchors for improved stability. METHODS: Postoperative implant position superimposed onto the preoperatively planned design using Mimics Medical 21.0 and Materialise Magics 24.0 to assess 3D coronal implant deviation, 3D apical implant deviation, and implant angular deviation. RESULTS: Postoperative cone-beam computed tomography (CBCT) revealed a high level of precision in the implant placement, with an average 0.97 mm deviation at implant coronal region, 1.56 mm at implant apexes, and 2.95° angular deviation. CONCLUSION: This technique introduces a novel cone-wedge anchoring mechanism to enhance the stability of stackable metal surgical guide templates, addressing inherent instability issues. The utilization of this approach significantly improves the accuracy of implant placement procedures.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Implantación Dental Endoósea/métodos , Implantación Dental Endoósea/instrumentación , Cirugía Asistida por Computador/métodos , Cirugía Asistida por Computador/instrumentación , Metales , Imagenología Tridimensional/métodos
12.
Orthop Surg ; 16(5): 1143-1152, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38561920

RESUMEN

OBJECTIVE: Medial opening-wedge high tibial osteotomy (MOWHTO) is a surgical procedure to treat medial compartment osteoarthritis in the knee with varus deformity. However, factors such as patellar height (PH) and the sagittal plane's posterior tibial slope angle (PTSA) are potentially overlooked. This study investigated the impact of alignment correction angle guided by computer-designed personalized surgical guide plate (PSGP) in MOWHTO on PH and PTSA, offering insights for enhancing surgical techniques. METHODS: This retrospective study included patients who underwent 3D-printed PSGP-assisted MOWHTO at our institution from March to September 2022. The paired t-tests assessed differences in all preoperative and postoperative measurement parameters. Multivariate linear regression analysis examined correlations between PTSA, CDI (Caton-Deschamps Index), and the alignment correction magnitude. Receiver operating characteristic (ROC) curve analysis determined the threshold of the correction angle, calculating sensitivity, specificity, and area under the curve. RESULTS: A total of 107 patients were included in our study. The CDI changed from a preoperative mean of 0.97 ± 0.13 (range 0.70-1.34) to a postoperative mean of 0.82 ± 0.13 (range 0.55-1.20). PTSA changed from a preoperative mean of 8.54 ± 2.67 (range 2.19-17.55) to a postoperative mean of 10.54 ± 3.05 (range 4.48-18.05). The t-test revealed statistically significant changes in both values (p < 0.05). A significant alteration in patellar height occurred when the correction angle exceeded 9.39°. Moreover, this paper illustrates a negative correlation between CDI change and the correction angle and preoperative PTSA. Holding other factors constant, each 1-degree increase in the correction angle led to a 0.017 decrease in postoperative CDI, and each 1-degree increase in preoperative PTSA resulted in a 0.008 decrease in postoperative CDI. PTSA change was positively correlated only with the correction angle; for each 1-degree increase in the opening angle, postoperative PTS increased by 0.188, with other factors constant. CONCLUSION: This study highlights the effectiveness and precision of PSGP-assisted MOWHTO, focusing on the impact of alignment correction on PH and PTSA. These findings support the optimization of PSGP technology, which offers simpler, faster, and safer surgeries with less radiation and bleeding than traditional methods. However, PSGP's one-time use design and the learning curve required for its application are limitations, suggesting areas for further research.


Asunto(s)
Osteoartritis de la Rodilla , Osteotomía , Rótula , Cirugía Asistida por Computador , Tibia , Humanos , Estudios Retrospectivos , Osteotomía/métodos , Femenino , Masculino , Persona de Mediana Edad , Tibia/cirugía , Rótula/cirugía , Adulto , Osteoartritis de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Impresión Tridimensional
13.
J Surg Case Rep ; 2024(4): rjae202, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38577268

RESUMEN

This report describes the bone reduction guide which was digitally obtained to improve diagnosis, treatment outcome and follow-up. Treatment of gingival smiles due to altered passive eruption should include interdisciplinary planning and smile design to facilitate the prediction of treatment outcome. Crown lengthening surgery can be supported by digital tools to improve surgical planning and follow-up. A 30-year-old female patient was referred to a private dental clinic seeking solutions for her gingival smile. Based on the anatomical crown length, a smile design was created, and the patient was presented with a simulated smile before treatment. In the surgical phase, a full-thickness flap was raised in the upper jaw to achieve the desired outcome. Using cone-beam computed tomography to determine cementoenamel junction for smile design and treatment planning brings many benefits. Patients and clinicians can foresee treatment results. From there, appropriate changes can be made. The bone reduction guide is designed to rest on the bone to help the clinician cut the bone accurately and thoroughly follow the established plan.

14.
Int J Med Robot ; 20(2): e2627, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38523327

RESUMEN

BACKGROUND: The aim of this scoping review was to understand the development of robotics and its accuracy in placing dental implants when compared to other forms of guided surgery. METHODS: An electronic search was conducted on the electronic databases of PubMed, Cochrane, and Science direct with the following queries: ((robotics) AND (dental implant)) AND (accuracy). The search timeline was between 2017 and 2022. RESULTS: A total of 54 articles were screened for title and abstract, of which 16 were deemed eligible for inclusion. Thirty-one articles were excluded mainly because they were out of topic (not relevant) or not in English. In total, 16 articles were included for analysis. CONCLUSIONS: This review thoroughly analyses 5 years of literature concerning the evolution of robotics in dental implant surgery, underscoring the necessity for additional research on nascent technologies reported and a comparative study with static and dynamic systems for clinical efficacy evaluation.


Asunto(s)
Implantes Dentales , Robótica , Cirugía Asistida por Computador , Humanos , Resultado del Tratamiento , Bases de Datos Factuales , Implantación Dental Endoósea , Diseño Asistido por Computadora , Imagenología Tridimensional , Tomografía Computarizada de Haz Cónico
15.
Cureus ; 16(2): e54771, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38523915

RESUMEN

In recent years, intraoperative surgical guides have been widely used in oral and maxillofacial surgery to navigate the resection sites. However, most of them are designed for segmental mandibulectomy and determine only the anterior-posterior cutting sites. In the case of marginal mandibulectomy, the depth and angle of the resection need to be considered in addition to the anterior-posterior cutting site. This report describes a method for creating a translucent mandible model with a colored tumor that enables visualization of the tumor depth and a surgical guide for marginal mandibulectomy with a planned resection angle. If accurate surgical planning and intraoperative navigation are established using this method, personalized surgery is realized according to tumor features and hence avoids over- or under-resection.

16.
Int J Comput Dent ; 27(1): 99-107, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38530272

RESUMEN

AIM: The purpose of this study was to present the use of computer-assisted periodontal surgery utilizing a novel surgical guide for cases with severe gingival enlargement through a clinical application in a patient with hereditary gingival fibromatosis. MATERIALS AND METHODS: The treatment plan included nonsurgical periodontal therapy, surgical periodontal treatment, and regular periodontal maintenance before the initiation of orthodontic treatment. Due to the increased soft tissue thickness, a surgical guide with a novel design was fabricated to facilitate the periodontal surgery since most of the patient's teeth were malpositioned and underexposed due to fibromatosis. For this purpose, the patient's intraoral scan was merged with a CBCT image in order to plan surgical excisions based on the anatomy of the teeth and the bone contour. RESULTS: The customized surgical guide facilitated the gingivectomy by controlling not only the shape of the initial incisions but also their orientation toward the level of the cementoenamel junction, improving the efficiency of the clinical time compared with freehand surgery and assisting in the verification of the final soft tissue shape, based on the treatment plan. CONCLUSION: Digital technology through the superimposition of multiple data sets can assist in the diagnosis and multidisciplinary management of cases with gingival fibromatosis. The proposed design of the surgical guide can facilitate soft tissue surgery based on the digital treatment plan, leading to more predictable management of the soft tissue, especially in patients with severe gingival enlargement, as in cases with hereditary gingival fibromatosis or drug-induced gingival overgrowth.


Asunto(s)
Fibromatosis Gingival , Hiperplasia Gingival , Hipertrofia Gingival , Sobrecrecimiento Gingival , Humanos , Fibromatosis Gingival/genética , Fibromatosis Gingival/cirugía
17.
Front Bioeng Biotechnol ; 12: 1350227, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38456007

RESUMEN

Fibula transplantation plays an irreplaceable role in restoring the function and morphology of the defected mandible. However, the complex load-bearing environment of the mandible makes it urgent to accurately reconstruct the mandible, ensure the position of the condyle after surgery, and restore the patient's occlusal function and contour. The intervention of digital design and three-dimensional (3D) printed titanium mesh provides a more efficient method and idea to solve this problem. Digital design guides the accurate positioning, osteotomy, and simultaneous implant placement during surgery, and 3D printed titanium mesh ensures stable condyle position after surgery, restoring good mandibular function. The double-layer folded fibula maintains the vertical height of the mandible and a good facial contour, and simultaneous implant placement can establish a good occlusal relationship. This study conducted a retrospective analysis of five patients with jaw defects who underwent digital fibula reconstruction over the past 3 years. It was found that the surgical protocol combining digital design, 3D printed intraoperative guides, 3D printed titanium mesh, free fibula flap, immediate implant, and occlusal reconstruction to repair jaw defects had more ideal facial appearance and biological function. It will provide a more reliable surgical protocol for clinical management of large mandibular defects.

18.
Sci Rep ; 14(1): 5722, 2024 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-38459159

RESUMEN

Accurate lesion diagnosis through computed tomography (CT) and advances in laparoscopic or robotic surgeries have increased partial nephrectomy survival rates. However, accurately marking the kidney resection area through the laparoscope is a prevalent challenge. Therefore, we fabricated and evaluated a 4D-printed kidney surgical guide (4DP-KSG) for laparoscopic partial nephrectomies based on CT images. The kidney phantom and 4DP-KSG were designed based on CT images from a renal cell carcinoma patient. 4DP-KSG were fabricated using shape-memory polymers. 4DP-KSG was compressed to a 10 mm thickness and restored to simulate laparoscopic port passage. The Bland-Altman evaluation assessed 4DP-KSG shape and marking accuracies before compression and after restoration with three operators. The kidney phantom's shape accuracy was 0.436 ± 0.333 mm, and the 4DP-KSG's shape accuracy was 0.818 ± 0.564 mm before compression and 0.389 ± 0.243 mm after restoration, with no significant differences. The 4DP-KSG marking accuracy was 0.952 ± 0.682 mm before compression and 0.793 ± 0.677 mm after restoration, with no statistical differences between operators (p = 0.899 and 0.992). In conclusion, our 4DP-KSG can be used for laparoscopic partial nephrectomies, providing precise and quantitative kidney tumor marking between operators before compression and after restoration.


Asunto(s)
Neoplasias Renales , Laparoscopía , Humanos , Nefrectomía/métodos , Riñón/diagnóstico por imagen , Riñón/cirugía , Riñón/patología , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/cirugía , Laparoscopía/métodos , Impresión Tridimensional
19.
J Stomatol Oral Maxillofac Surg ; : 101853, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38555078

RESUMEN

BACKGROUND: Tooth-supported surgical guides have demonstrated superior accuracy compared with bone-supported guides. This study aimed to modify the fabrication of tooth-supported guides for compatibility with tumor resection procedures and investigate their accuracy. METHODS: Patients with tumors who underwent osteotomy with the assistance of modified tooth- or bone-supported surgical guides were included. Virtual surgical planning (VSP) was employed to align three dimensional (3D) models extracted from intraoperative computed tomography (CT) images. The distances and angular deviations between the actual osteotomy plane and preoperative plane were recorded. A comparative analysis of osteotomy discrepancies between tooth-supported and bone-supported guides, as well as among tooth-supported guides based on CT, cone-beam CT (CBCT), or intraoral scanner (IOS) was conducted. The factors influencing the precision of the guides were analyzed. RESULTS: Sixty patients with 81 resection planes were included in this study. In the tooth-supported group, the mean deviations in the osteotomy plane and angle were 1.39 mm and 4.30°, respectively, whereas those of the bone-supported group were 2.16 mm and 4.95°. In the tooth-supported isotype guide groups, the mean deviations of the osteotomy plane were 1.39 mm, 1.47 mm, 1.23 mm across CT, CBCT, and IOS, respectively. The accuracy of the modified tooth-supported guides remained consistent regardless of number and position of the teeth supporting the guide and location of the osteotomy lines. CONCLUSIONS: The findings indicate that the modified tooth-supported surgical guides demonstrated high accuracy in the maxillofacial region, contributing to a reduction in the amount of surgically detached soft tissue.

20.
3D Print Med ; 10(1): 8, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38427154

RESUMEN

BACKGROUND: Accurate repositioning of the femoral head in patients with Slipped Capital Femoral Epiphysis (SCFE) undergoing Imhäuser osteotomy is very challenging. The objective of this study is to determine if preoperative 3D planning and a 3D-printed surgical guide improve the accuracy of the placement of the femoral head. METHODS: This retrospective study compared outcome parameters of patients who underwent a classic Imhäuser osteotomy from 2009 to 2013 with those who underwent an Imhäuser osteotomy using 3D preoperative planning and 3D-printed surgical guides from 2014 to 2021. The primary endpoint was improvement in Range of Motion (ROM) of the hip. Secondary outcomes were radiographic improvement (Southwick angle), patient-reported clinical outcomes regarding hip and psychosocial complaints assessed with two questionnaires and duration of surgery. RESULTS: In the 14 patients of the 3D group radiographic improvement was slightly greater and duration of surgery was slightly shorter than in the 7 patients of the classis Imhäuser group. No difference was found in the ROM, and patient reported clinical outcomes were slightly less favourable. CONCLUSIONS: Surprisingly we didn't find a significant difference between the two groups. Further research on the use of 3D planning an 3D-printed surgical guides is needed. TRIAL REGISTRATION: Approval for this study was obtained of the local ethics committees of both hospitals.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...