Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Braz. j. otorhinolaryngol. (Impr.) ; 88(2): 194-203, Mar.-Apr. 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1374721

RESUMEN

Abstract Introduction: Endolymphatic hydrops is the pathophysiological substrate of Ménière's disease. The changes in the inner ear, transmitted to the middle ear through changes in the ossicular chain mobility, can be quantified by wideband tympanometry, through the measurement of the acoustic absorbance at multiple frequencies, represented by the sound energy absorbed by the middle ear, even at its early stages. Studying the behavior of the middle ear through the absorbance in patients with endolymphatic hydrops under ambient pressure and under peak pressure can be useful for detecting Ménière's disease. Objective: To characterize acoustic absorbance behavior in subjects with symptomatic and asymptomatic Ménière's disease compared to controls, in order to verify the ability of wideband tympanometry to detect Ménière's disease. Methods: We carried out a cross-sectional study with a diagnostic approach comparing the findings of wideband tympanometry at ambient pressure and peak pressure between the ears of the control group (n = 30), the asymptomatic group (n = 21) and the symptomatic group (n = 9). Results: Different peak pressure values were found between the ears of the control group (0daPa), the asymptomatic group (−11 daPa) and the symptomatic group (−192 daPa), with p < 0.05 by the Kruskal-Wallis test, Mann Whitney test and Bonferroni correction. Different absorbance values were found between the ears of the symptomatic group and the asymptomatic group compared to the control group for low frequencies at ambient pressure and peak pressure, with p < 0.05 by the Kruskal-Wallis test, Mann Whitney test and Bonferroni correction. Conclusions: The Wideband Tympanometry test was capable of identifying the presence of Ménières disease, and to differentiate between asymptomatic and symptomatic patients, when comparing them with healthy individuals.


Resumo Introdução: A hidropsia endolinfática é o substrato fisiopatológico da doença de Ménière. As alterações desencadeadas na orelha interna, transmitidas à orelha média pelas modificações na mobilidade da cadeia ossicular, podem ser quantificadas pela timpanometria de banda larga, através da medida da absorvância acústica sob múltiplas frequências, representadas pela energia sonora absorvida pela orelha média, mesmo em estágios iniciais de sua instalação. Estudar o comportamento da orelha média através da absorvância em pacientes com hidropisia endolinfática sob pressão ambiente e sob o pico de pressão pode ser útil na detecção da doença de Ménière. Objetivo: Caracterizar o comportamento da absorvância em indivíduos com diagnóstico da doença de Ménière sintomáticos e assintomáticos, comparados com controles, a fim de verificar a capacidade da timpanometria de banda larga em detectar variações clínicas relacionadas a possível hidropisia endolinfática. Método: Foi realizado um estudo transversal, com enfoque diagnóstico, que comparou os achados da timpanometria de banda larga na pressão ambiente e no pico de pressão entre orelhas do grupo controle (n = 30), grupo assintomático (n = 21) e grupo sintomático (n = 9). Resultados: Foram encontrados valores do pico de pressão diferentes entre orelhas do grupo controle (0 daPa), do grupo assintomático (-11 daPa) e do grupo sintomático (-192 daPa), com p <0,05 pelos testes de Kruskal-Wallis, Mann Whitney e correção de Bonferroni. Foram encontrados valores de absorvância diferentes entre orelhas do grupo sintomático e do grupo assintomático em relação ao grupo controle para as frequências baixas na pressão ambiente e na pressão de pico, com p < 0,05 pelos testes de Kruskal-Wallis, Mann Whitney e correção de Bonferroni. Conclusão: A timpanometria de banda larga foi um teste capaz de identificar a presença da doença de Ménière e de diferenciar os pacientes assintomáticos e sintomáticos, comparando-os com indivíduos hígidos.


Asunto(s)
Humanos , Hidropesía Endolinfática , Oído Interno , Enfermedad de Meniere/diagnóstico , Pruebas de Impedancia Acústica , Estudios Transversales
2.
Audiol., Commun. res ; 25: e2261, 2020. tab
Artículo en Portugués | LILACS | ID: biblio-1131794

RESUMEN

RESUMO Objetivo Analisar as emissões otoacústicas evocadas produto de distorção (EOAPD) de indivíduos adultos entre 18 e 50 anos, com audição normal, e associar os resultados com os achados à timpanometria. Métodos Foram selecionados 27 prontuários de adultos com audição dentro dos padrões de normalidade, sem queixa auditiva, com curva timpanométrica do tipo A, Ad ou Ar, presença de reflexos acústicos, sem queixa de zumbido e de exposição frequente a níveis de pressão sonora elevados, com repouso auditivo mínimo de 14 horas no momento do exame e que realizaram o exame de emissões otoacústicas evocadas produto de distorção. Os resultados do exame de emissões otoacústicas foram analisados considerando os resultados das curvas timpanométricas apresentadas por estes indivíduos. Para análise dos dados foram aplicados testes não paramétricos e o nível de significância foi de 5%. Resultados foram analisados os resultados das emissões otoacústicas de 54 orelhas. Observou-se maior ocorrência da curva do tipo A em indivíduos sem queixas auditivas. Independente do lado, a maioria das orelhas que apresentou resposta presente ao exame de EOAPD, apresentou, também, curva timpanométrica normal. Observou-se correlação positiva entre a amplitude das EOAPD e o volume da orelha média para as frequências de 6000 Hz e uma tendência à significância em 4000 Hz Conclusão Foi possível concluir que há maior ocorrência de emissões otoacústicas presentes em indivíduos com audição normal e curva timpanométrica do tipo A e que a amplitude das EOAPD em 6000 Hz mostra-se menor nos indivíduos com audição normal e curva timpanométrica do tipo Ar ou Ad.


ABSTRACT Purpose To analyze distortion product evoked otoacoustic emissions in normal-hearing adults aged between 18 and 50 years old, and to associate the results with the findings of tympanometry. Methods 27 medical records were selected of adults with the following conditions: normal hearing; without auditory complaint; with type A, Ad or Ar tympanometric curve; with presence of acoustic reflexes; with no complaint of tinnitus or frequent exposure to high sound pressure levels; with minimal auditory rest of 14 hours at the time of the test, and who had undergone distortion product evoked otoacoustic emission (DPOAE) testing. The results of otoacoustic emissions were analyzed considering the results of the tympanometric curves presented by these individuals. For the data analysis, non-parametric tests were applied, and the level of significance was 5%. Results The results of otoacoustic emissions of 54 ears were analyzed. There was a greater occurrence of the type A curve in individuals without auditory complaints. Regardless of side, most ears whose response was present in the DPOAE test also presented normal tympanometric curve. There was a positive correlation between DPOAE amplitude and middle ear volume for the 6000Hz frequencies (p = 0.048) and a tendency to significance at 4000Hz (p = 0.054). Conclusion There was a higher occurrence of otoacoustic emissions present in normal-hearing individuals and type A tympanometric curve, and the amplitude of DPOAE at 6000Hz was smaller in normal-hearing individuals and type Ar or Ad tympanometric curve.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Reflejo Acústico/fisiología , Pruebas de Impedancia Acústica , Emisiones Otoacústicas Espontáneas/fisiología , Pruebas Auditivas , Audiometría , Umbral Auditivo
3.
Braz. j. otorhinolaryngol. (Impr.) ; 85(2): 193-198, Mar.-Apr. 2019. graf
Artículo en Inglés | LILACS | ID: biblio-1001557

RESUMEN

Abstract Introduction: Tympanometry is currently the most frequently used tool for assessing the status of the middle ear, commonly assessed using a single 226 Hz tone. However, the use of the Acoustic Immittance Measures with a wideband stimulus is a promising high-resolution evaluation, especially in individuals known to have middle ear alterations, such as Down syndrome patients. Objective: The aim of this study was to analyze the acoustic absorbance measurements in children with Down syndrome. Methods: Cross-sectional study, approved by the institution's ethics committee. Data were collected from 30 children, with a mean age of 8.4 years, 15 with Down syndrome (DS-study group) and 15 children with typical development and no hearing complaints (control group). Energy absorbance was measured at frequencies of 226-8000 Hz at ambient pressure and at peak pressure as a function of frequency using TITAN equipment. Statistical analysis was performed using the established level of statistical significance of 5%. Results: With the 226 Hz probe tone, 30 ears of the control group and 22 of the study group exhibited Type A tympanograms, whereas Type B was observed in eight children in the study group. The mean acoustic absorbance ratio of the study group was lower than that of the control group at frequencies centered at 2520 Hz (p = 0.008) for those with normal tympanometry results, and 226-4000 Hz (p < 0.03) for those with a Type B tympanometry curve. Conclusion: The low energy absorption in the presence of normal tympanograms in children with Down syndrome may suggest middle ear abnormalities.


Resumo Introdução: A timpanometria é a ferramenta mais usada para avaliar o status da orelha média, comumente avaliada por meio de uma única frequência com o tom de 226 Hz. No entanto, o uso da medida de imitância acústica com estímulo de banda larga é uma avaliação de alta resolução promissora, especialmente em pacientes conhecidos por frequentemente apresentar alterações da orelha média, como na síndrome de Down. Objetivo: Analisar as medidas de absorvância acústica em crianças com síndrome de Down. Método: Estudo transversal, aprovado pelo comitê de ética da instituição. Foram coletados dados de 30 crianças, com idade média de 8,4 anos, sendo 15 com síndrome de Down (SD-grupo de estudo) e 15 crianças desenvolvimento típico e sem queixas auditivas (grupo controle). A absorvância de energia foi medida nas frequências de 226-8.000 Hz à pressão ambiente e no pico de pressão em função da frequência, usou-se o equipamento Titan. A análise estatística foi feita com o nível de significância estatística adotado de 5%. Resultados: Com o tom de sonda de 226 Hz foram observadas 30 orelhas do grupo controle e 22 do grupo estudo com timpanometria Tipo A e o Tipo B foi observado apenas em oito crianças do grupo estudo. A razão média de absorvância acústica do grupo estudo foi menor do que a do controle nas frequências centradas em 2.520 Hz (p = 0,008) para aqueles com resultados timpanométricos normais e de 226-4.000 Hz (p < 0,03) para aqueles com curva timpanométrica Tipo B. Conclusão: A baixa absorção de energia na presença de timpanogramas normais nas crianças com síndrome de Down pode sugerir anormalidades na orelha média.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Pruebas de Impedancia Acústica/métodos , Síndrome de Down/fisiopatología , Oído Medio/fisiopatología , Valores de Referencia , Estudios de Casos y Controles , Estudios Transversales , Estadísticas no Paramétricas , Enfermedades del Oído/diagnóstico , Enfermedades del Oído/fisiopatología
4.
Braz J Otorhinolaryngol ; 85(2): 193-198, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29396164

RESUMEN

INTRODUCTION: Tympanometry is currently the most frequently used tool for assessing the status of the middle ear, commonly assessed using a single 226Hz tone. However, the use of the Acoustic Immittance Measures with a wideband stimulus is a promising high-resolution evaluation, especially in individuals known to have middle ear alterations, such as Down syndrome patients. OBJECTIVE: The aim of this study was to analyze the acoustic absorbance measurements in children with Down syndrome. METHODS: Cross-sectional study, approved by the institution's ethics committee. Data were collected from 30 children, with a mean age of 8.4 years, 15 with Down syndrome (DS-study group) and 15 children with typical development and no hearing complaints (control group). Energy absorbance was measured at frequencies of 226-8000Hz at ambient pressure and at peak pressure as a function of frequency using TITAN equipment. Statistical analysis was performed using the established level of statistical significance of 5%. RESULTS: With the 226Hz probe tone, 30 ears of the control group and 22 of the study group exhibited Type A tympanograms, whereas Type B was observed in eight children in the study group. The mean acoustic absorbance ratio of the study group was lower than that of the control group at frequencies centered at 2520Hz (p=0.008) for those with normal tympanometry results, and 226-4000Hz (p<0.03) for those with a Type B tympanometry curve. CONCLUSION: The low energy absorption in the presence of normal tympanograms in children with Down syndrome may suggest middle ear abnormalities.


Asunto(s)
Pruebas de Impedancia Acústica/métodos , Síndrome de Down/fisiopatología , Oído Medio/fisiopatología , Estudios de Casos y Controles , Niño , Estudios Transversales , Enfermedades del Oído/diagnóstico , Enfermedades del Oído/fisiopatología , Femenino , Humanos , Masculino , Valores de Referencia , Estadísticas no Paramétricas
5.
Bauru; s.n; 2017. 85 p. ilus, tab, graf.
Tesis en Portugués | LILACS | ID: biblio-880703

RESUMEN

Na prática clínica, nota-se uma dificuldade em identificar a rigidez do sistema tímpano-ossicular decorrente da Otosclerose por meio dos métodos de avaliação rotineiramente empregados. Assim, as medidas de imitância acústica de banda larga podem fornecer mais informações sobre a condição do sistema tímpano-ossicular por avaliarem uma ampla faixa de frequência. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em indivíduos com diagnóstico de Otosclerose submetidos à estapedectomia ou estapedotomia. Foram avaliados 40 indivíduos na faixa etária de 33 a 80 anos, totalizando 54 orelhas operadas e 22 orelhas não operadas. A avaliação audiológica foi realizada por meio da otoscopia, audiometria tonal liminar, logoaudiometria e imitanciometria. As medidas de imitância acústica de banda larga foram obtidas por meio do sistema de medidas Middle-Ear Power Analyzer MEPA3, versão 5.0 (Mimosa Acoustics), utilizando os estímulos tom puro e chirp. Os dados obtidos foram submetidos à análise estatística descritiva e inferencial, com nível de significância de 0,05. As orelhas com Otosclerose apresentaram maior absorvância em 750 Hz, uma tênue diminuição até 3000 Hz, acentuando-se a partir desta frequência. A magnitude da admitância foi maior na faixa de frequência de 1992 a 4008 Hz, assim como a magnitude da impedância foi maior nas frequências baixas com diminuição até 4008 Hz e aumento em 6000 Hz. Estas orelhas foram dominadas pela rigidez nos sons graves e médios, por resistência entre 3000 e 4008 Hz e a partir desta frequência pela massa. A fase da impedância foi maior em 258 Hz e o delay da reflectância (slope) apresentou uma variação de comportamento entre as frequências, não sendo possível caracterizar um padrão de resposta. Conclui-se que há diferenças nas medidas obtidas nas orelhas com Otosclerose submetidas à cirurgia, quando analisadas as frequências baixas e médias, o que demonstra o impacto positivo da intervenção cirúrgica na funcionalidade do sistema tímpano-ossicular.(AU)


In clinical practice, there is a difficulty in identifying the rigidity of the tympano-ossicular system resulting from Otosclerosis through the routinely employed evaluation methods. Thus, wideband acoustic immitance measurements can provide more information on the condition of the tympanic-ossicle system by evaluating a wide frequency range. This study aimed at characterizing the wideband acoustic immitance measurements with the pure tone and chirp stimuli in individuals diagnosed with Otosclerosis submitted to stapedectomy or stapedotomy. Forty individuals aged 33 to 80 years were evaluated, totaling 54 operated and 22 non-operated ears. Audiology assessment was performed through otoscopy, pure-tone audiometry, logoaudiometry and imitanciometry. Wideband acoustic immitance measurements were obtained using the Middle-Ear Power Analyzer (MEPA3), version 5.0 (Mimosa Acoustics), by means of pure tone and chirp stimuli. Data were submitted to descriptive and inferential statistical analysis, with a significance level of 0.05. The ears with Otosclerosis presented a greater absorbance in 750 Hz, a slight diminution until 3000 Hz, being accentuated from this frequency. The admittance magnitude was higher in the frequency range from 1992 to 4008 Hz, as well as the impedance magnitude was higher in the low frequencies with a decrease up to 4008 Hz and an increase in 6000 Hz. These ears were dominated by rigidity in the low and medium sounds, by resistance between 3000 and 4008 Hz, and from this frequency, by the mass. The impedance phase was higher at 258 Hz and the reflectance delay (slope) showed a behavioral variation between the frequencies, a response not being characterized. It can be concluded that there are differences in the measurements obtained in Otosclerosis ears submitted to surgery, when the low and medium frequencies were analyzed, which demonstrates the positive impact of the surgical intervention on the tympano-ossicle system.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Audiometría/métodos , Osículos del Oído/fisiopatología , Oído Medio/fisiopatología , Otosclerosis/fisiopatología , Pruebas de Impedancia Acústica/métodos , Análisis de Varianza , Valores de Referencia , Estadísticas no Paramétricas
6.
Audiol., Commun. res ; 20(4): 300-304, out.-dez. 2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-770546

RESUMEN

RESUMO Objetivo: Caracterizar os valores de reflectância e absorvância de banda larga em lactentes com integridade de orelha média. Métodos: Foram analisados os valores de reflectância e absorvância de banda larga, para os estímulos chirp e tom puro, de 31 orelhas de 18 lactentes, na faixa etária de 10 dias a cinco meses de idade. Considerou-se como critérios de inclusão: ausência de fator de risco para deficiência auditiva, timpanometria com sonda de 1000 Hz, sugerindo normalidade de orelha média e presença de emissões otoacústicas evocadas por estímulo transiente, na triagem auditiva neonatal. Resultados: Os valores de reflectância mostraram-se maiores para as baixas frequências, reduzindo para as médias e aumentando, novamente, para as frequências altas, enquanto para os valores de absorvância, o comportamento foi o oposto. Não existiu diferença significativa entre os estímulos chirp e tom puro. Conclusão: Observou-se um comportamento típico das medidas estudadas, caracterizado por maior reflectância nas frequências graves e maior absorvância para as frequências médias.


ABSTRACT Purpose: To characterize the wideband reflectance and absorbance values in infants with middle ear integrity. Methods: The wideband reflectance and absorbance values for chirp and pure tone stimuli of 31 ears of infants aged 10 days to five months were analyzed. Inclusion criteria considered: 1000 Hz tympanometry. suggesting normal middle ear and the presence of transient evoked otoacoustic emission. Results: The reflectance values were shown to be greater for low frequencies, reducing to medium ones and increasing once again to high frequencies, while the absorbance values displayed an opposite behavior. No significant difference was verified between chirp and pure tone stimuli. Conclusion: A typical behavior of the measures, characterized by a higher reflectance at low frequencies and higher absorbance at medium frequencies was observed in the population studied.


Asunto(s)
Humanos , Recién Nacido , Lactante , Pruebas de Impedancia Acústica , Oído Medio , Pérdida Auditiva Conductiva , Emisiones Otoacústicas Espontáneas , Audiometría de Respuesta Evocada , Estudios Transversales , Lactante , Tamizaje Neonatal , Otitis Media
7.
Rev. CEFAC ; 17(5): 1403-1414, sept.-out. 2015. tab, graf
Artículo en Portugués | LILACS | ID: lil-765104

RESUMEN

Resumo:OBJETIVO:caracterizar o perfil audiológico de escolares do primeiro ano do Ensino Fundamental da rede municipal da cidade de Caxias do Sul-RS, investigando e identificando a ocorrência de alterações auditivas nesta população, por meio de medidas eletroacústicas.MÉTODOS:estudo transversal, prospectivo, descritivo e quantitativo de 391 escolares do primeiro ano do Ensino Fundamental de escolas municipais da cidade de Caxias do Sul-RS. Os estudantes foram submetidos a quatro procedimentos audiológicos na Triagem Auditiva Escolar: Meatoscopia, Emissões Otoacústicas Evocadas por Estímulo Transiente, Emissões Otoacústicas - Produto de Distorção e Timpanometria. Além disso, os responsáveis pelas crianças responderam a um questionário com perguntas referentes ao desenvolvimento e aos antecedentes otológicos de cada criança. Os escolares que apresentaram alguma alteração auditiva na Triagem Auditiva foram encaminhados para avaliação otorrinolaringológica e/ou avaliação audiológica completa.RESULTADOS:das 782 orelhas avaliadas, 85,4% apresentaram normalidade nos exames realizados e 14,6% demonstraram algum tipo de alteração. Na Meatoscopia, verificou-se que 6,3% das orelhas apresentaram alterações. Passaram nas Emissões Otoacústicas Evocadas por Estímulo Transiente 94,8% das orelhas e nas Emissões Otoacústicas - Produto de Distorção 95,8%. Na Timpanometria, a curva predominante foi a tipo A, seguida pela tipo C. Foram realizados encaminhamentos para 14,6% dos escolares.CONCLUSÃO:a população desse estudo foi composta, em sua maioria, por escolares do gênero masculino, com seis anos de idade. Das 782 orelhas avaliadas, 85,4% apresentaram normalidade nos exames realizados e 14,6% demonstraram algum tipo de alteração.


Abstract:PURPOSE:to characterize the audiological profile of first grade students from municipal elementary schools in Caxias do Sul (RS), Brazil, using electroacoustic measures to investigate and identify the occurrence of hearing impairments in this population.METHODS:prospective descriptive quantitative cross-sectional study of 391 first grade students from municipal elementary schools in Caxias do Sul (RS), Brazil. Students were submitted to four audiological procedures for the hearing screening: meatoscopy, Transient Evoked Otoacustic Emissions, Distortion Product Otoacoustic Emissions, and tympanometry. Furthermore, caregivers answered a questionnaire regarding each child's development and otologic history. The students who presented hearing deficits on the hearing screening were referred for otorhinolaryngological and/or complete audiological evaluation.RESULTS:from the 782 ears evaluated, 85.4% presented normal results, and 14.6% showed alterations. In the meatoscopy, 6.3% of the ears showed alterations, while 94.8% passed the Transient Evoked Otoacustic Emissions and 95.8%, the Product-Distortion Otoacoustic Emissions. The tympanometry showed predominance of type A curves, followed by type C. Referrals were made for 14.6% of the students.CONCLUSION:the sample of this study was composed mostly by male school-age children with six years of age. From the 782 ears evaluated, 85.4% had normal results on the screening, and 14.6% showed alterations.

8.
CoDAS ; 27(3): 223-229, May-Jun/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-753091

RESUMEN

PURPOSE: To analyze the occurrence of acoustic reflex and its threshold on newborns using the 226 and 1,000 Hz probes. METHODS: Thirty-six newborns with "PASS" results in newborn hearing screening and tympanogram with one or two peaks for both probe tones were included. Group I comprised 20 full-term newborns without risk indicator for hearing loss, and Group II comprised 16 newborns with at least one risk indicator. The study about ipsilateral acoustic reflex thresholds was conducted in 500, 1,000, 2,000, and 4,000 Hz. RESULTS: The groups presented the acoustic reflex thresholds between 50 and 100 dB for both probe tones. In the comparison between the probes, there were differences in all frequencies evaluated in Group I, with the lowest threshold mean for the 1,000 Hz probe. In Group II, differences were detected at 2,000 Hz. The mean acoustic reflex thresholds were similar in both groups for the 226 Hz probe. There was a difference for the 1,000 Hz probe in all tested frequencies. The percentage of response was higher in both groups for the 1,000 Hz probe. The kappa test showed extremely poor agreement in the comparison of results between both probes. CONCLUSION: The occurrence of acoustic reflex was higher in newborns and its thresholds were lower with the 1,000 Hz probe both for healthy newborns and for newborns at risk. .


OBJETIVO: Verificar a ocorrência e o limiar do reflexo acústico em neonatos utilizando a sonda de 226 e 1.000 Hz. MÉTODOS: Trinta e seis neonatos com resultado "PASS" na triagem auditiva neonatal e timpanogramas com um ou dois picos para os dois tons de sonda. O Grupo I foi composto por 20 neonatos a termo sem indicador de risco para deficiência auditiva e o Grupo II, por 16 neonatos com pelo menos um indicador de risco. A pesquisa dos limiares do reflexo acústico ipsilateral foi realizada em 500, 1.000, 2.000 e 4.000 Hz. RESULTADOS: Os grupos apresentaram limiar do reflexo acústico entre 50 e 100 dB para ambos os tons de sonda. Na comparação entre as sondas, houve diferença em todas as frequências avaliadas no Grupo I, com a média de limiares menor com a sonda de 1.000 Hz. No Grupo II, foi detectada diferença em 2.000 Hz. Com a sonda de 226 Hz, os limiares médios do reflexo acústico foram semelhantes nos dois grupos. Com a sonda de 1.000 Hz, houve diferença em todas as frequências avaliadas. A porcentagem de presença de resposta foi maior para ambos os grupos para a sonda de 1.000 Hz. O teste kappa revelou concordância extremamente pobre na comparação dos resultados entre as duas sondas. CONCLUSÃO: A ocorrência de reflexo acústico em neonatos foi maior e os limiares menores com a utilização da sonda de 1.000 Hz, tanto para neonatos saudáveis como para os neonatos de risco. .


Asunto(s)
Femenino , Humanos , Recién Nacido , Masculino , Pruebas de Impedancia Acústica/instrumentación , Umbral Auditivo/fisiología , Reflejo Acústico/fisiología , Estudios de Casos y Controles , Factores de Riesgo
9.
Bauru; s.n; 2015. 115 p. ilus, tab, graf.
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-867259

RESUMEN

A avaliação da integridade do sistema tímpano-ossicular é um pré-requisito para que o processo de diagnóstico audiológico infantil possa ser concluído com precisão, assim, muito têm se discutido em relação aos procedimentos utilizados na prática clínica para definir a presença ou ausência de problema condutivo. Nesse sentido, as medidas de imitância acústica de banda larga mostram-se como uma opção para o avanço na área. Diante disso, surgiu o interesse em ampliar os conhecimentos e trazer as características das medidas de imitância acústica de banda larga nas diferentes condições de orelha média. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em crianças com perda auditiva sensorial de grau severo e profundo e diferentes padrões timpanométricos. Foram avaliadas 187 orelhas de 98 crianças na faixa etária de seis a 60 meses de idade, subdivididas em grupos de acordo com a pressão e compliância obtidas na timpanometria com sonda de 226 Hz. As medidas de imitância acústica de banda larga foram realizadas por meio do sistema de medidas do Acoustics' Middle-Ear Power Analyzer - MEPA, versão 5.0, utilizando os estímulos tom puro e chirp, com faixa de frequência de 211 a 6000 Hz. Os valores de compliância e pressão obtidos na timpanometria convencional foram correlacionados às medidas de imitância acústica de banda larga, adotando-se testes estatísticos apropriados, com nível de significância de 0,05. Os resultados obtidos evidenciaram o efeito das faixas de frequência (grave, média e aguda) em todas as medidas analisadas, com exceção do delay da reflectância. Foi constatada influência de pressões correspondentes a -100 daPa ou mais negativas e também para pressões positivas acima de 25 daPa, e compliâncias menores que 0,2 ml nas medidas de imitância acústica de banda larga. Além disso, houve diferença significante entre os estímulos tom puro e chirp para frequências baixas...


The evaluation of the integrity of the tympanic-ossicular system is a prerequisite for the child audiology diagnostic process to be completed accurately, thus, much has been discussed in relation to the procedures used in clinical practice to define the presence or absence of conductive problems. Hence, the wideband acoustic immittance measurements show to be an option to the advance in the field. As a result, the interest in expanding the knowledge and bringing the characteristics of wideband acoustic immittance measurements in the different conditions of middle ear, emerged. This study aimed at characterizing the wideband acoustic immittance measurements using pure and chirp stimuli in children presented with severe and profound sensorineural hearing loss and different tympanometric standards. 187 ears of 98 children in the age range six-sixty months, subdivided into groups according to pressure and compliance achieved through tympanometry with a 226 Hz probe, were assessed. Wideband acoustic immittance measurements were performed by the measuring system of the Acoustics' Middle-Ear Power Analyzer - MEPA, version 5.0, using pure and chirp tone stimuli, in a frequency ranging from 211 to 6000 Hz. The values of compliance and pressure obtained through conventional tympanometry were correlated with wideband acoustic immittance measures, by applying suitable statistical tests, with a 0.05 significance level. The results achieved evidenced the effect of frequency bands (low, medium and high) in all measures examined, with the exception of the reflectance delay. The Influence of pressures -100 daPa or more negative ones and also in positive pressures above 25 Pa, and compliance lower than 0.2 ml in the wideband acoustic immittance measurements, was verified. In addition, there was a significant difference between pure tone and chirp stimuli at low frequencies for impedance absorbance and magnitude, with a greater reflex of the variation of compliance...


Asunto(s)
Humanos , Masculino , Femenino , Lactante , Preescolar , Estimulación Acústica/métodos , Pérdida Auditiva Sensorineural/fisiopatología , Pruebas de Impedancia Acústica/métodos , Análisis de Varianza , Audiometría de Tonos Puros/métodos , Valores de Referencia , Índice de Severidad de la Enfermedad
10.
Bauru; s.n; 2015. 115 p. ilus, tab, graf.
Tesis en Portugués | LILACS | ID: lil-756764

RESUMEN

A avaliação da integridade do sistema tímpano-ossicular é um pré-requisito para que o processo de diagnóstico audiológico infantil possa ser concluído com precisão, assim, muito têm se discutido em relação aos procedimentos utilizados na prática clínica para definir a presença ou ausência de problema condutivo. Nesse sentido, as medidas de imitância acústica de banda larga mostram-se como uma opção para o avanço na área. Diante disso, surgiu o interesse em ampliar os conhecimentos e trazer as características das medidas de imitância acústica de banda larga nas diferentes condições de orelha média. O objetivo do estudo foi caracterizar as medidas de imitância acústica de banda larga com os estímulos tom puro e chirp em crianças com perda auditiva sensorial de grau severo e profundo e diferentes padrões timpanométricos. Foram avaliadas 187 orelhas de 98 crianças na faixa etária de seis a 60 meses de idade, subdivididas em grupos de acordo com a pressão e compliância obtidas na timpanometria com sonda de 226 Hz. As medidas de imitância acústica de banda larga foram realizadas por meio do sistema de medidas do Acoustics' Middle-Ear Power Analyzer - MEPA, versão 5.0, utilizando os estímulos tom puro e chirp, com faixa de frequência de 211 a 6000 Hz. Os valores de compliância e pressão obtidos na timpanometria convencional foram correlacionados às medidas de imitância acústica de banda larga, adotando-se testes estatísticos apropriados, com nível de significância de 0,05. Os resultados obtidos evidenciaram o efeito das faixas de frequência (grave, média e aguda) em todas as medidas analisadas, com exceção do delay da reflectância. Foi constatada influência de pressões correspondentes a -100 daPa ou mais negativas e também para pressões positivas acima de 25 daPa, e compliâncias menores que 0,2 ml nas medidas de imitância acústica de banda larga. Além disso, houve diferença significante entre os estímulos tom puro e chirp para frequências baixas...


The evaluation of the integrity of the tympanic-ossicular system is a prerequisite for the child audiology diagnostic process to be completed accurately, thus, much has been discussed in relation to the procedures used in clinical practice to define the presence or absence of conductive problems. Hence, the wideband acoustic immittance measurements show to be an option to the advance in the field. As a result, the interest in expanding the knowledge and bringing the characteristics of wideband acoustic immittance measurements in the different conditions of middle ear, emerged. This study aimed at characterizing the wideband acoustic immittance measurements using pure and chirp stimuli in children presented with severe and profound sensorineural hearing loss and different tympanometric standards. 187 ears of 98 children in the age range six-sixty months, subdivided into groups according to pressure and compliance achieved through tympanometry with a 226 Hz probe, were assessed. Wideband acoustic immittance measurements were performed by the measuring system of the Acoustics' Middle-Ear Power Analyzer - MEPA, version 5.0, using pure and chirp tone stimuli, in a frequency ranging from 211 to 6000 Hz. The values of compliance and pressure obtained through conventional tympanometry were correlated with wideband acoustic immittance measures, by applying suitable statistical tests, with a 0.05 significance level. The results achieved evidenced the effect of frequency bands (low, medium and high) in all measures examined, with the exception of the reflectance delay. The Influence of pressures -100 daPa or more negative ones and also in positive pressures above 25 Pa, and compliance lower than 0.2 ml in the wideband acoustic immittance measurements, was verified. In addition, there was a significant difference between pure tone and chirp stimuli at low frequencies for impedance absorbance and magnitude, with a greater reflex of the variation of compliance...


Asunto(s)
Humanos , Masculino , Femenino , Lactante , Preescolar , Estimulación Acústica/métodos , Pérdida Auditiva Sensorineural/fisiopatología , Pruebas de Impedancia Acústica/métodos , Análisis de Varianza , Audiometría de Tonos Puros/métodos , Valores de Referencia , Índice de Severidad de la Enfermedad
11.
Audiol., Commun. res ; 19(4): 421-425, Oct-Dec/2014. tab, graf
Artículo en Portugués | LILACS | ID: lil-732227

RESUMEN

O objetivo deste trabalho foi analisar as medidas de reflectância em uma paciente com otosclerose. A paciente, do gênero feminino, 51 anos, apresentava queixa de hipoacusia bilateral e a hipótese diagnóstica de otosclerose. Foram realizados os seguintes testes de avaliação audiológica: imitanciometria, audiometria tonal, vocal e medidas de reflectância acústica, em ambas as orelhas. Por meio da análise dos resultados da reflectância acústica de banda larga, foi possível observar aumento na reflectância, característico de otosclerose, entre as frequências de 500 e 1500 Hz, e diferenciar a orelha esquerda e a orelha direita. As medidas de reflectância permitiram a obtenção de resultados detalhados por frequência que, em conjunto, possibilitaram a diferenciação entre as duas orelhas. O uso da reflectância de banda larga é sugerido para complementar o diagnóstico da otosclerose.


This research aimed to analyze the reflectance measurements in a patient with otosclerosis. The patient, female, 51 years old; she complained of bilateral hearing loss and had a diagnosis hypothesis of otosclerosis. The following audiological tests were performed in both ears: tympanometry, pure-tone audiometry, and speech audiometry tests and acoustic reflectance measurements. Through acoustic wideband reflectance analysis, it was possible to observe an increase in reflectance, such as is seen in otosclerotic ears, between the frequencies of 500 Hz and 1500 Hz and to differentiate the left and right ear. Acoustic reflectance measurements have the potential to yield results that allow the differentiation between the two ears; thus, the use of the wideband acoustic reflectance is suggested as a part of the otosclerosis diagnostic procedure.


Asunto(s)
Humanos , Femenino , Pruebas de Impedancia Acústica/métodos , Audiometría , Pérdida Auditiva Bilateral/diagnóstico , Pérdida Auditiva/diagnóstico , Otosclerosis/diagnóstico , Pruebas Auditivas/métodos
12.
Rev. CEFAC ; 16(6): 1783-1790, Nov-Dec/2014. tab, graf
Artículo en Portugués | LILACS | ID: lil-736273

RESUMEN

OBJETIVO: verificar a ocorrência de simetria maior ou igual à 70%, entre as orelhas, comparando os resultados da timpanometria nas frequências de 226 e 1000Hz com as respostas das emissões otoacústicas em neonatos. MÉTODOS: foram avaliados 39 neonatos, em média com 60 horas de vida, sendo 20 do sexo feminino e 19 do sexo masculino. Cada recém-nascido foi submetido à avaliação timpanométrica com as sondas de 226 e 1000 Hz, e avaliação das emissões otoacústicas transientes em ambas as orelhas. Os resultados foram submetidos a testes estatísticos. RESULTADOS: na análise da amostra pode-se observar ocorrência de simetria <70% nas respostas das emissões otoacústicas em 74,4% do total de neonatos. Por outro lado, na timpanometria, houve uma maior ocorrência de simetria ≥ 70%, tanto para sonda de 226 quanto para 1000Hz (76,9% e 84,6%, respectivamente). No que diz respeito ao gênero e orelha, as diferenças encontradas em cada teste não foram significantes, embora tenha sido observada maior amplitude de respostas de emissões otoacústicas na orelha direita. CONCLUSÃO: os resultados sugerem haver simetria no sistema auditivo em sua porção mais periférica, e início de assimetrias a partir da cóclea. .


PURPOSE: to determine the occurrence of symmetry ≥ 70% between the ears, comparing the results of 226- and 1000-Hz tympanograms with otoacoustic emissions in neonates. METHODS: thirty-nine neonates (20 female and 19 male) were evaluated at an average age of 60 hours. Each newborn underwent 226- and 1000-Hz probe tone tympanometry and evaluation of the transient-evoked otoacoustic emissions in both ears. The results were subjected to statistical tests. RESULTS: occurrence of symmetry < 70% was observed in otoacoustic emissions for 74.4% of the neonates. Tympanometry produced a greater occurrence of symmetry ≥ 70% for both the 226- and 1000-Hz probe tones (76.9% and 84.6%, respectively). With regard to gender and ear, the differences in each test were not significant, although greater otoacoustic emission amplitude was observed for the right ear. CONCLUSION: the results suggest symmetry in the auditory system in its most peripheral portion, and asymmetries begin to occur from the cochlea. .

13.
Rev. CEFAC ; 16(5): 1406-1418, Sep-Oct/2014. tab
Artículo en Portugués | LILACS | ID: lil-729924

RESUMEN

OBJETIVO: realizar um estudo comparativo das medidas de imitância acústica em tabagistas e não tabagistas, visando identificar a ocorrência de um comportamento específico na população tabagista. MÉTODOS: em uma amostra 80 indivíduos, 40 tabagistas e 40 não tabagistas, foram obtidos o volume do meato acústico externo, a admitância, a pressão de pico e o gradiente. RESULTADOS: os resultados mostraram que pressão de pico apresentou diferença significante entre os grupos, revelando-se mais negativa no grupo dos tabagistas, tanto para a orelha direita (p=0,004) quanto para a esquerda (p=0,011). Nas demais medidas investigadas não foram verificadas diferenças estatísticas. CONCLUSÃO: Desta forma, o presente estudo conclui que a pressão do pico do timpanograma é uma medida imitanciométrica capaz de diferenciar tabagistas e não tabagistas, sendo que nos tabagistas a pressão mostra-se significantemente mais negativa. .


PURPOSE: to conduct a comparative study of the acoustic impedance measurements in smokers and nonsmokers, in order to identify the occurrence of specific behavior in the smoking population. METHODS: in a sample of 80 individuals, namely 40 smokers and 40 nonsmokers, we obtained the outer acoustic meatus volume, the admittance, the peak pressure and the gradient. RESULTS: the results showed that the peak pressure presented a significant difference between the groups, revealing itself more negative in the group of smokers, both for the right ear (p=0.004) and for the left ear (p=0.011). CONCLUSION This study concludes that the peak pressure of the tympanogram is an immittance measure able to differentiate smokers and nonsmokers, where smokers show significantly more negative pressures. .

14.
Rev. CEFAC ; 16(4): 1097-1108, Jul-Aug/2014. tab, graf
Artículo en Portugués | LILACS | ID: lil-724053

RESUMEN

Objetivos analisar a relação entre o uso de fones de ouvidos e os comprometimentos auditivos e extra-auditivos provocados pelos tocadores portáteis de música. Métodos a proposta foi coletar dados, por meio de um questionário respondido pelos participantes. Realização dos exames audiométricos: audiometria tonal e vocal; imitânciometria e pesquisa dos reflexos acústicos; emissões otoacústicas transientes e emissões otoacústicas produto de distorção, posteriormente os dados foram comparados entre os indivíduos de um mesmo grupo e os grupos foram comparados entre si (grupo experimental e grupo controle). Para a análise estatística foi utilizado o teste Qui-Quadrado e exato de Fisher. Resultados algumas das variáveis investigadas, tais como o uso de fones de ouvido de 1 a 2 horas diárias, a presença de queixas auditivas e extra-auditivas, exposição a níveis de pressão sonora elevados extra-ocupacional uma vez por semana, ser não fumante, não usar medicamentos controlados e não apresentar zumbido possuíram frequência estatisticamente significante para o grupo experimental. Em relação às queixas auditivas houve diferença estatisticamente significante entre os grupos experimental e controle para sensação de ouvido abafado e sensação de rebaixamento auditivo. Conclusão os sintomas temporários indicam os potenciais efeitos nocivos de ouvir tocadores portáteis de música por uma hora ao dia. Pesquisas ainda são necessárias para avaliar os prejuízos de longo prazo ao sistema auditivo. .


Purpose to examine the relationship between the use of headphones and hearing impairments and hearing caused by portable music players. Methods the purpose was to collect data through a questionnaire answered by the participants. Realization of audiometric tests: tonal and vocal audiometry, immittance, and acoustic reflexes, transient otoacoustic emissions and distortion product otoacoustic emissions, subsequently the data were compared between individuals of the same group and the groups were compared itself (the experimental group and control group). For statistical analysis we used the chi-square and Fisher exact test. Results some of the variables investigated, such as the use of headphones 1 to 2 hours a day, the presence of non auditory and auditory complaints, exposure to high sound pressure levels of extra-occupational once a week to be nonsmoker do not use drugs prescription and not ringing often possessed statistically significant for the experimental group. Regarding hearing complaints there was a statistically significant difference between the experimental and control groups concerning the feeling of muffled ear and sensation of decreased hearing. Conclusion the temporary symptoms indicate the potential harmful effects of listening to portable music players for an hour a day. Research is needed to assess long-term damage to the auditory system. .

15.
Rev. CEFAC ; 15(6): 1453-1460, nov.-dez. 2013. graf, tab
Artículo en Portugués | LILACS | ID: lil-700031

RESUMEN

OBJETIVO: caracterizar e comparar os achados timpanométricos de um grupo de escolares. MÉTODO: foram avaliados 112 escolares, de ambos os gêneros, na faixa etária de quatro anos a cinco anos e onze meses que frequentavam uma Escola Municipal de Educação Infantil, localizada em um bairro periférico da cidade de Marília. Como procedimento de triagem, utilizou-se a timpanometria. Considerou-se que a criança PASSOU na triagem quando apresentou curva timpanométrica do tipo A, bilateralmente, sendo reavaliada em caso de falha. RESULTADOS: observou-se um alto índice de falha (63,4%) na população estudada. Os escolares de maior faixa etária e do gênero feminino apresentaram um índice maior de timpanogramas do tipo A, em ambas as orelhas. Houve uma maior incidência de falha nas crianças de faixa etária entre 4 anos e 4 anos e 11 meses, e do gênero masculino. CONCLUSÃO: nesta amostra obteve-se um alto índice de alterações timpanométricas. Houve uma tendência de escolares do gênero masculino e de menor faixa etária apresentarem um índice maior de alterações timpanométricas quando comparados ao gênero feminino e de maior faixa etária, não sendo esta diferença estatisticamente significante.


PURPOSE: to characterize and compare the tympanometric findings in a group of preschoolers. METHOD: 112 preschoolers were evaluated, both genders, aged from four years old to five years and eleven months old who attended a Municipal School of Early Childhood Education in the suburbs of Marilia city- SP. Tympanometry was used as triage procedure. It was considered that the child PASSED in the triage when it presented an A type tympanometric curve, bilaterally, being reevaluated in case of failure. RESULTS: it was observed a high failure index (63.4%) in the studied population. The older female preschoolers presented a higher index of A type tympanograms, in both ears. There was a higher incidence of failure in male preschoolers aged from four years to four years and eleven months. CONCLUSION: in this sample, there was a high index of tympanometric alteration. There was a tendency among younger male students to present a higher index of tympanometric alteration when compared to older female preschoolers, this difference was not statistically significant.

16.
Audiol., Commun. res ; 18(2): 126-132, abr.-jun. 2013. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-684500

RESUMEN

OBJETIVO: Estudar as medidas de volume, pressão do pico e complacência obtidas nas curvas timpanométricas de neonatos, na comparação entre gêneros e orelhas, utilizando tom sonda de 226 e 1000 Hz, e analisar as respostas obtidas na pesquisa dos reflexos acústicos com os dois tons de sonda testados. MÉTODOS: Foram avaliados 73 neonatos, com integridade de células ciliadas externas verificadas pelas emissões otoacústicas evocadas transientes. Foi realizada a avaliação das medidas de imitância acústica nas crianças, tendo como desfecho clínico a observação das respostas obtidas nas timpanometrias e na pesquisa dos reflexos acústicos com tom sonda de 226 e 1000 Hz. RESULTADOS: Observamos diferença entre as curvas de pico único e pico duplo, com maior ocorrência de pico único com tom sonda de 1000 Hz. Verificamos diferença entre os gêneros, na medida complacência em 226 Hz e entre as orelhas, nas medidas complacência e pressão do pico em 226 e 1000 Hz, respectivamente. Encontramos, também, diferença nas médias dos reflexos acústicos ipsilaterais e contralaterais com tom sonda de 1000 Hz, em relação a variável gênero, e entre os reflexos ipsilaterais e contralaterais nas frequências de 1000 e 2000 Hz com tom sonda de 226 e 1000 Hz. CONCLUSÃO: Houve diferença entre as variáveis analisadas com tom sonda de 226 e 1000 Hz. Os valores de compliância e de reflexos foram mais elevados no gênero feminino. Todos os neonatos apresentaram reflexos acústicos, sendo os contralaterais mais elevados que os ipsilaterais.


PURPOSE: Study the measures of volume, peak pressure and complacency in tympanometric curves of neonates with gender, ears and tone probe of 226 and 1000 Hz and analyze the responses obtained in the survey of the acoustic reflections with the two tone probe tested. METHODS: transversal study, observational and contemporary. We evaluated 73 neonatal with integrity of outer hair cells observed by transient evoked otoacoustic emissions. The children performed the evaluation of measures of acoustic immittance clinical outcome, observation of the answers obtained in tympanometries and research of acoustic reflexes with tone probe 226 and 1000 Hz. RESULTS: We observed statistically significant difference between the curves of single and double peak, with a higher occurrence of single peak with tone probe of 1000 Hz. There was statistically significant difference between the genders as complacency in 226 Hz and between the ears in compliance measures and peak pressure in 226 and 1000 Hz, respectively. In addition, we found statistically significant difference in the average of the ipsilateral and contralateral acoustic reflexes with tone probe of 1000 Hz against the variable gender and ipsilateral and contralateral reflexes between the frequencies of 1000 and 2000 Hz with tone probe of 226 and 1000 Hz. CONCLUSION: The results obtained in this study showed statistically significant difference between analyzed variables with tone probe of 226 and 1000 Hz tone. The compliance values and reflexes were higher in females. All neonates had acoustic reflexes, and reflexes contralateral higher than the ipsilateral.


Asunto(s)
Humanos , Recién Nacido , Pruebas de Impedancia Acústica/estadística & datos numéricos , Pérdida Auditiva Conductiva/diagnóstico , Pérdida Auditiva Sensorineural/diagnóstico , Emisiones Otoacústicas Espontáneas , Reflejo Acústico , Adaptabilidad
17.
CoDAS ; 25(3): 202-208, 2013. graf, tab
Artículo en Portugués | LILACS | ID: lil-680031

RESUMEN

OBJETIVO: Investigar o comportamento auditivo de pacientes com insuficiência renal crônica submetidos ao transplante renal. MÉTODOS: Foram avaliados 30 pacientes, 10 do gênero feminino e 20 do gênero masculino, na faixa etária de 13 a 26 anos (média de idade 16,97 anos). Os sujeitos foram submetidos a anamnese, avaliação otorrinolaringológica, avaliação audiológica convencional e de altas frequências, medidas de imitância acústica e avaliação do processamento auditivo central. Para os resultados da audiometria de altas frequências foi utilizado um grupo controle. RESULTADOS: Os sujeitos não apresentaram queixas auditivas na anamnese. Os resultados da audiometria convencional demonstraram predomínio da normalidade; na audiometria de altas frequências, os pacientes apresentaram resultados piores do que os sujeitos do grupo controle. Na imitanciometria houve predomínio de curva tipo A bilateral. Na avaliação do processamento auditivo central, 14 sujeitos (46,67%) apresentaram resultados alterados no Staggered Spondaic Word Test (SSW). Houve diferença significativa entre a variável idade e o resultado da audiometria tonal limiar: quanto maior a idade, menor a sensibilidade auditiva nos limiares de 250 Hz a 8 kHz. Houve relação entre o tipo de doador (cadáver ou vivo) e o resultado do teste SSW: os índices de resultados alterados foram maiores quando o doador era cadáver, em comparação com casos de doador vivo. CONCLUSÃO: Houve alterações na avaliação audiológica convencional e de altas frequências e no processamento auditivo central de sujeitos com insuficiência renal crônica submetidos ao transplante renal, sugerindo a necessidade de orientação à equipe envolvida quanto aos cuidados, prevenção e identificação precoce de acometimentos audiológicos.


PURPOSE: To investigate the auditory behavior of patients with chronic renal failure (CRF) undergoing kidney transplantation. METHODS: Thirty patients were evaluated, 10 (33.33%) females and 20 (66.67%) males, aging from 13 to 26 years (average, 16.97 years; standard deviation, 3.60 years). Patients underwent the following procedures: anamnesis, otolaryngological examination, audiological evaluation (pure tone and high frequency), acoustic impedance measurements and central auditory processing evaluation. A control group was used to compare the high-frequency audiometry results. RESULTS: The following observations were made: absence of auditory complaints at the time of anamnesis; pure-tone audiometry was predominantly normal; patients presented lower hearing levels at the high-frequency audiometry, when compared to the control group, and as for the acoustic impedance measurements, curves of the type A were predominant; there was a change of the central auditory processing for 14 patients (46.67%) in the Staggered Spondaic Word Test (SSW); there was a significant difference between the age variable and the result of the pure-tone audiometry, that is, hearing sensitivity in thresholds from 250Hz to 8,000Hz decreased with advancing age; and the relation between the type of donor and the SSW test result was significant. Rates were higher when the patients had been transplanted from deceased donors compared to living donors. CONCLUSION: There were no changes in conventional audiological and high-frequency evaluation, or in the central auditory processing. Professionals involved in the care of kidney transplantation recipients must be better informed about the care, prevention, and early identification of auditory disorders.


Asunto(s)
Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Trastornos de la Audición/etiología , Trasplante de Riñón , Fallo Renal Crónico/complicaciones , Audiometría , Umbral Auditivo , Estudios de Casos y Controles , Pruebas Auditivas , Fallo Renal Crónico/fisiopatología
18.
CoDAS ; 25(1): 29-33, 2013. ilus, tab
Artículo en Portugués | LILACS | ID: lil-672154

RESUMEN

OBJETIVO: Caracterizar os valores normais de reflectância da energia acústica obtidos com estímulo de tom puro na população neonatal antes da alta hospitalar. MÉTODOS: Setenta e sete recém-nascidos (37 meninas e 40 meninos) foram avaliados por meio das medidas de reflectância acústica, utilizando estímulos de tom puro, emissões otoacústicas por transientes e timpanometria com sondas de frequências de 226 Hz e 1 kHz. RESULTADOS: Nas baixas frequências (258 a 750 Hz) foi observado um valor elevado de reflectância da energia, enquanto nas médias frequências (1 a 3 kHz) obteve-se uma maior absorção da energia. Não existiu diferença entre orelhas e entre gêneros. CONCLUSÃO: Foram caracterizados os valores normais de reflectância da energia para a população estudada. Tais dados revelaram uma curva de reflectância com configuração peculiar para a idade.


PURPOSE: To characterize the normal values of acoustic energy reflectance obtained with pure-tone stimulation in neonates prior to hospital discharge. METHODS: Seventy-seven infants (37 girls and 40 boys) were evaluated by measuring acoustic reflectance using pure-tone stimuli, transient-evoked otoacoustic emissions, and tympanometric probe frequencies of 226 Hz and 1 kHz. RESULTS: At low frequencies (258-750 Hz), greater energy reflectance was observed, while at medium frequencies (1-3 kHz), greater energy absorption was observed. There was no difference between ears or between genders. CONCLUSION: Normal energy reflectance values were obtained for the studied population. The data indicate a reflectance curve with a distinct configuration for the studied age.


Asunto(s)
Femenino , Humanos , Recién Nacido , Masculino , Audiometría de Tonos Puros , Estimulación Acústica/métodos , Oído Medio/fisiología , Emisiones Otoacústicas Espontáneas/fisiología , Pruebas de Impedancia Acústica , Tamizaje Neonatal/métodos , Valores de Referencia
19.
Int. arch. otorhinolaryngol. (Impr.) ; 16(3): 353-357, jul.-set. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-646371

RESUMEN

Introduction: The resonant frequency is the probe frequency in which susceptance is 0 due to the neutralization of the forces of mass and stiffness components that control the middle ear. This frequency can be evaluated by multifrequency tympanometry, and the normality value for adults ranges 800-1,200 Hz. Studies about resonant frequency in children are scarce. Aim: Identify the variation of the resonant frequency in infants between the first days after birth and the third month of life. Method: Prospective study. Thirty newborns were evaluated at 2 different times: at the neonatal phase up to 12 days of life, and between 72 and 84 days of life. In the first evaluation, we carried out otoacoustic emissions and identified the resonant frequency, and identified the resonant frequency again in the second evaluation. Results: In the first evaluation, we determined a mean resonance value of 250 Hz for both ears, while that in the second evaluation was 385 Hz. In both assessments, we found no significant differences between the ears. There was a significant difference between the first and second evaluation. Conclusion: The middle ear resonant frequency in infants is lower in the first days of life due to the influence of the mass component. The present study demonstrated that the resonance frequency increased in the first months of life...


Asunto(s)
Humanos , Masculino , Femenino , Recién Nacido , Niño , Adolescente , Oído Medio , Pruebas Auditivas , Emisiones Otoacústicas Espontáneas , Pérdida Auditiva/prevención & control , Factores de Riesgo , Pruebas de Impedancia Acústica/efectos adversos
20.
Int. arch. otorhinolaryngol. (Impr.) ; 16(3): 365-370, jul.-set. 2012. ilus, tab
Artículo en Portugués | LILACS | ID: lil-646373

RESUMEN

Introduction: Old age is associated with changes in the characteristics of the middle ear transmission system and in external ear resonance, and these carry implications for the hearing aid (HA) verification process for which targets and measures of the real ear insertion gain (REIG) are used. Aim: To compare the real ear unaided gain (REUG) and the equivalent volumes of the external ear (VeqEE) and the middle ear (VeqME) between elderly and adult patients. Methods: This is a retrospective study in which the medical records of 28 elderly patients (aged between 61 and 102 years, average hearing thresholds between 38.75 and 85 dB HL) and 23 adult patients (aged 20-59, mean hearing thresholds between 31.25 and 116.25 dB HL) with bilateral sensorineural hearing loss and no history of middle ear abnormalities were analyzed. Immittance measurements (VeqEE, VeqME, and pressure of the peak of maximum compliance) and the REUG (frequency and amplitude of the primary peak) were recovered for a total of 40 ears. These data were compared between elderly and adults as well as between men and women, using Student's t test. Correlations (Pearson) between immittance and REUG data were also verified. Results: No statistically significant differences (p < 0.01) were found for immittance and REUG data between elderly and adults, or between men and women. A negative and weak but significant correlation was observed between the REUG primary peak and VeqEE. Conclusion: Hearing aid verification can be performed with target and measures of the REIG in the elderly population...


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano de 80 o más Años , Pruebas de Impedancia Acústica , Envejecimiento , Audiometría , Grupos Control , Pabellón Auricular , Audífonos , Oído Medio/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...