Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 777
Filtrar
1.
J Funct Biomater ; 15(8)2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39194666

RESUMEN

Multilayer monolithic zirconia, which incorporates polychromatic layers that mimic natural tooth gradients, offers enhanced aesthetics and functionality while reducing debonding risks and improving fabrication efficiency. However, uncertainties remain regarding the fracture characteristics of multilayer monolithic zirconia crowns under occlusal loading, whether composed of uniform or combined yttria levels. The current study investigated how variations in yttria levels and thicknesses affected the optical properties and fracture loads of multilayer monolithic zirconia. Samples of multilayer monolithic zirconia in the Vita A1 shade were used, while employing 3Y (SZ) and 4Y + 5Y (AZ) yttria levels. The optical properties, including the color difference (ΔEWS) and translucency parameters (TP00), were measured using a digital colorimeter. The fracture loads were analyzed using a universal testing machine, and fractured surfaces were examined under a stereomicroscope. Statistical analyses assessed the impacts of the yttria levels and sample thicknesses on the optical properties. The ΔEWS values of SZ ranged 3.6 to 4.0, while for AZ, ΔEWS at 0.5 mm was 3.9 and <2.6 for other thicknesses. The TP00 values decreased with an increased thickness, with AZ generally exhibiting greater translucency than SZ. In the fracture load investigations, SZ (>1600 N) generally exceeded AZ (>1260 N), with fracture loads notably increasing with thickness, particularly for premolars (SZ > 3270 N, AZ > 2257 N). SZ predominantly exhibited partial and complete fractures, whereas AZ showed fewer non-fracture categorizations. Complete fractures began with dense, irregular cracks that extended outward to reveal smooth surfaces, while premolars subjected to higher loads exhibited concentric ripple-like structures. Partial fractures revealed radial textures indicative of areas of stress concentration. In summary, higher yttria levels were correlated with increased translucency, while variations in the fracture loads primarily stemmed from differences in the tooth position or thickness. Overall, multilayer monolithic zirconia incorporating combined yttria levels of 4Y + 5Y (AZ) offered high translucency, precise color matching, and substantial fracture resistance, rendering it highly suitable for aesthetic and functional dental applications.

2.
Clin Oral Investig ; 28(9): 473, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110133

RESUMEN

PURPOSE: To investigate the effects of different surface treatments and thicknesses on the color, transparency, and surface roughness of ultra-transparent zirconia. METHODS: A total of 120 Katana ultra-translucent multi-layered zirconia specimens were divided into 12 groups according to the thickness (0.3, 0.5, and 0.7 mm) and surface treatment (control, airborne particle abrasion [APA], lithium disilicate coating, and glaze on). Color difference (ΔE00) and relative translucency parameter (RTP00) were calculated using a digital spectrophotometer. The surface roughness (Ra, Rq, Sa, and Sq) was measured using a non-contact profile scanner. The surface morphologies and microstructures of the samples were observed using a tungsten filament scanning electron microscope. Statistical analyses were performed by one-way and two-way analysis of variance (ANOVA) followed by post hoc multiple comparisons and Pearson's correlation (α = 0.05). RESULTS: The results showed that the surface treatment, ceramic thickness, and their interactions had significant effects on ΔE00 and RTP00 (p < 0.001). The surface treatment significantly altered the micromorphology and increased the surface roughness of the ceramic samples. APA exhibited the lowest transparency, largest color difference, and highest surface roughness. Zirconia with 0.3 mm and 0.7 mm thicknesses showed strong negative correlations between Sa and RTP00. CONCLUSIONS: The three internal surface treatments significantly altered the surface roughness, color difference, and transparency of ultra-transparent zirconia. As the thickness increased, the influence of the inner surface treatment on the color difference and transparency of zirconia decreased. CLINICAL IMPLICATIONS: For new zirconia internal surface treatment technologies, in addition to considering the enhancement effect on the bonding properties, the potential effects on the color and translucency of high-transparency zirconia should also be considered. Appropriately increasing the thickness of zirconia restorations helps minimize the effect of surface treatment on the optical properties.


Asunto(s)
Color , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Espectrofotometría , Propiedades de Superficie , Circonio , Circonio/química , Porcelana Dental/química , Materiales Dentales/química , Recubrimiento Dental Adhesivo/métodos
3.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 49(4): 603-610, 2024 Apr 28.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-39019789

RESUMEN

OBJECTIVES: In clinical ultrasound examinations, it is challenging to perform quality control on the images of each fetal nuchal translucency (NT) and crown-rump length (CRL). However, small measurement differences can increase the probability of false-positive or false-negative diagnosis. Therefore, it is necessary to establish a quality control system for fetal NT examination. This study aims to control the quality of fetal NT and CRL measurements, evaluate the accuracy of ultrasound physicians in early pregnancy NT measurements, and analyze the impact of increased fetal structure screening on the detection rate of chromosomal abnormalities. METHODS: Data were collected from cases before and after 12 months of NT examination quality control, with 2 214 before quality control and 2 538 cases after quality control. Three quality control data metrics were analyzed: NT multiple of median (NT-MoM), standard deviation (SD) of log10MoM [(SD) log10MoM], and the slope of NT on CRL (SNC). The performance of NT measurements was monitored through the individual CRL NT-MoM within the 0.9-1.1 MoM range of the normal median curve, while grouped based on different years of experience (<3 years, 3-6 years, >6 years), and NT-MoM values among these groups were compared. Data on NT thickening, structural anomalies, and chromosomal abnormalities were retrospectively analyzed during the quality control period. RESULTS: According to the curve equation of the American NTQR project group, the NT-MoM value before quality control was 0.921 7 MoM, the (SD) log10MoM value was 0.091 92, and the SNC value was 12.20%. After quality control, the NT-MoM value was 0.948 3 MoM, the (SD) log10MoM value was 0.094 81, and the SNC value was 11.43%. The comparison of NT-MoM values before and after quality control showed a statistically significant difference (P<0.000 1). The comparison of NT-MoM values measured by ultrasound physicians with different years of experience before and after quality control also showed statistically significant differences (P<0.000 1). The NT-MoM values for the 3-6 years and >6 years groups were higher after quality control (P<0.05), while the <3 years group showed no significant difference before and after quality control (P>0.05). After quality control, cases of NT thickening without significant structural abnormalities accounted for 19.05%, NT thickening with structural abnormalities accounted for 47.62%, and NT normal with structural abnormalities accounted for 33.33%. There were 36 cases of fetal heart abnormalities, accounting for 20.34% of the total abnormality rate, with a positive rate of 36% in chromosome tests. CONCLUSIONS: After quality control, ultrasound physicians measure NT more accurately, but differences among measurements remain. Measurements by experienced ultrasound physicians are closer to expected values, usually lower than expected. Monitoring fetal NT and CRL measurements helps improve measurement accuracy. Increasing structural screening during NT examinations, especially for the fetal heart, enhances the detection rate of chromosomal abnormalities.


Asunto(s)
Largo Cráneo-Cadera , Medida de Translucencia Nucal , Control de Calidad , Ultrasonografía Prenatal , Humanos , Medida de Translucencia Nucal/normas , Femenino , Embarazo , Ultrasonografía Prenatal/métodos , Ultrasonografía Prenatal/normas , Aberraciones Cromosómicas/embriología , Adulto
4.
Poult Sci ; 103(9): 103983, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38954901

RESUMEN

Eggshell quality is a significant characteristic that influences consumer preferences. Eggshell translucency is a common defect in the appearance of eggshells, which are characterized by gray spots that are visible to the naked eye under natural light. The presence of various defects resulting from eggshell translucency has caused a decrease in consumer willingness to purchase eggs, leading to considerable economic losses in the egg industry. Although the impact of eggshell translucency on food safety, egg quality, and hatchability has been extensively investigated, the classification and causes of eggshell translucency remain unclear and lack a systematic summary. In recent studies, new interpretations of evaluation methods and causes of eggshell translucency have been proposed, along with numerous innovative solutions. Therefore, this paper aims to provide a comprehensive review of the evaluation methods, classification, causes, effects, and influencing factors of eggshell translucency and to summarize the treatments for translucent eggs. We believe that this review will serve as a valuable reference for researchers involved in the study of translucent eggs.


Asunto(s)
Pollos , Cáscara de Huevo , Animales , Pollos/fisiología , Cáscara de Huevo/fisiología , Femenino , Huevos/análisis , Crianza de Animales Domésticos/métodos
5.
Poult Sci ; 103(9): 103963, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39013295

RESUMEN

Eggshell translucency is a widespread issue in the field of egg quality. Previous research has established that the heritability of eggshell translucency is relatively low or moderate. Scientists have also successfully identified SNP loci related to eggshell translucency on different chromosomes by using gene chips and single-variant GWAS. However, the specific impact of single or multiple genes on the trait of eggshell translucency remains unknown. In an effort to investigate this, we examined 170 SNPs associated with eggshell translucency obtained by our research group. We selected 966 half-sibling laying hens from 2 generations in 3 pure lines: Dwarf Layer-White, Rhode Island Red-White Strain, and Rhode Island Red. Eggs were collected from each hen over a period of 5 consecutive days, and eggshell translucency was measured using a grading method in which the hens were divided into 2 groups: an opaque group and a translucent group. We collected blood samples from the laying hens and extracted DNA. Time of flight mass spectrometry (TOF-MS) was used for genotyping to identify SNP loci that influence the trait of eggshell translucency. The results of our analysis revealed that using TOF-MS in 3 chicken strains, we were able to eliminate loci with low gene polymorphism, genetic effect contribution less than 1%, and deviation from Hardy-Weinberg equilibrium. Ultimately, 5 SNPs (Affx-50362599, rs15050262, rs312943734, rs316121113, and rs317389181) were identified on chromosomes 1, 5, and 19. Additionally, nine candidate genes (DCN, BTG1, ZFP92, POU2F1, NUCB2, FTL, GGNBP2, ACACA, and TADA2A) were found to be associated with these SNPs. No linkage disequilibrium relationship was observed between the 2 pairs of SNP loci on chromosomes 1 and 19. Based on previous studies on the formation mechanism of eggshell translucency, we hypothesize that NUCB2, FTL, and ACACA genes may be affecting the eggshell structure through different mechanisms, such as increase the water permeability or make thin of eggshell membrane, which promote moisture or part of other egg contents and ultimately lead to the formation of eggshell translucency. These findings validate and identify five SNP loci that regulate the translucency trait, and provide molecular markers for breeding non-translucent populations. Furthermore, this study serves as a reference for further investigation of the genetic regulatory mechanisms underlying eggshell translucency.


Asunto(s)
Pollos , Cáscara de Huevo , Polimorfismo de Nucleótido Simple , Animales , Pollos/genética , Femenino
6.
J Esthet Restor Dent ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39076148

RESUMEN

OBJECTIVES: To evaluate the color-match with extracted natural teeth of three single-shade universal composites, a group-shade universal composite, and a highly translucent-shade conventional composite. METHODS: Twenty extracted human teeth were divided into light- and dark-shade groups (n = 10, LSG and DSG). A preparation was restored with the 3 single-shade universal composites, OMNICHROMA (OMC), Admira Fusion x-tra U (AFU), and Essentia U (ESU); a highly translucent-shade conventional composite, Tetric EvoCeram T (TEC-T); and two shades of a group-shade universal composite-Filtek Universal Restorative (FUR A1 and A4). Composites were photopolymerized, polished, and stored in water for 24 h. The ΔE00 value between the unprepared and restored surfaces was obtained using a spectrophotometer. Composite placement and measurements were repeated three times per tooth. Color differences were statistically analyzed with the within-between-subjects t-test and repeated-measures analysis of variance (ANOVA), followed by post hoc pairwise comparisons with a Bonferroni adjustment (α = 0.05). RESULTS: There were no statistically significant differences between OMC and FUR (A1 and A4). AFU and ESU showed significantly higher ΔE00 values than OMC and TEC-T (p < 0.05). Single-shade composites exhibited significantly higher ΔE00 values in the DSG than in the LSG except ESU (p < 0.05). None of the composites satisfied the criteria for an acceptable match (ΔE00 >1.8). CONCLUSION: OMC showed the same color matching ability as a group-shade universal composite. A highly translucent-shade conventional composite and OMC exhibited better color matching ability than other single-shade composites. Overall, single-shade universal composites performed better in lighter-shaded teeth. CLINICAL SIGNIFICANCE: Single-shade universal composites have the potential to reduce chair time by eliminating shade selection in cavities with lighter-shade teeth. Highly translucent incisal conventional composites also may be used if the appropriate shade of composite is not available.

7.
J Esthet Restor Dent ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39076158

RESUMEN

OBJECTIVE: To evaluate the effect of polishing and bleaching on the recovery of lightness, color, whiteness, and relative translucency parameter (RTP) in CAD/CAM materials and changes in these properties when another staining in coffee was conducted after the treatments. MATERIALS AND METHODS: Disks of Lava Ultimate (LU), Vita Enamic (VE), IPS Empress CAD (EMP), IPS e.max CAD (EMAX), and Vita Suprinity (VS) were (1) not treated (control), (2) polished with Proxyt or (3) Ceramisté, (4) bleached with Opalescence PF or (5) Whiteness HP Blue, and (6) air polished with Clinpro Prophy Powder. CIE L*a*b* color coordinates were registered at baseline (R0), after staining with coffee for 30 min daily for 36.5 days and treatment (R1), and after another staining (R2). Differences (R1-R0 and R2-R0) in lightness (ΔL00), color (ΔE00), RTP (ΔRTP00), and whiteness (ΔWID) were evaluated by mixed repeated measures ANOVA and 95% confidence intervals (α = 0.05) and interpreted in function of their respective 50:50% PT and AT thresholds. Topography was evaluated by scanning electron microscopy (SEM). RESULTS: In LU, Opalescence PF and Proxyt decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {\mathrm{R}}_0\right)} $$ , and ΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ and showed lower Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ . In VE, all treatments decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , and ΔWI D R 1 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_1\hbox{--} {R}_0\right)} $$ , whereas Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ , and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ were lower in Opalescence PF than in the control group. In both moments, ΔE00 and ΔWID in EMP (also ΔL00) and EMAX were higher in Opalescence PF than in the control group, from which the other treatments did not differ in R1-R0. In EMP, Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ in Whiteness HP Blue (also Δ L 00 R 2 - R 0 $$ {\Delta L}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ ) and Proxyt were also higher in comparison to the control group and in VS, Ceramisté decreased Δ L 00 R 1 - R 0 $$ {\Delta L}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , Δ E 00 R 1 - R 0 $$ {\Delta E}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , and Δ R T P 00 R 1 - R 0 $$ \varDelta RT{P}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ , whereas Opalescence PF increased ΔRTP 00 R 1 - R 0 $$ {\Delta \mathrm{RTP}}_{00\left({R}_1\hbox{--} {R}_0\right)} $$ . Δ E 00 R 2 - R 0 $$ {\Delta E}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Ceramisté and ΔWI D R 2 - R 0 $$ {\Delta \mathrm{WI}}_{\mathrm{D}\left({R}_2\hbox{--} {R}_0\right)} $$ and Δ R T P 00 R 2 - R 0 $$ \varDelta RT{P}_{00\left({R}_2\hbox{--} {R}_0\right)} $$ of Proxyt were lower than those of the control group. CONCLUSIONS: The most suitable treatment to recover the lightness, color, whiteness, and RTP without changing these properties after another coffee exposure is material-dependent. CLINICAL SIGNIFICANCE: Although the effectiveness of the treatment was material-dependent, Proxyt was the only treatment that promoted clinically acceptable changes for both LU and VE, while for purely ceramic materials, this condition was observed with Ceramisté and Clinpro Prophy Powder.

8.
Sci Rep ; 14(1): 15206, 2024 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-38956329

RESUMEN

The study investigated the effects of temperature and centrifugation time on the efficacy of removing uncured resin from 3D-printed clear aligners. Using a photo-polymerizable polyurethane resin (Tera Harz TC-85, Graphy Inc., Seoul, Korea), aligners were printed and subjected to cleaning processes using isopropyl alcohol (IPA) or centrifugation (g-force 27.95g) at room temperature (RT, 23 °C) and high temperature (HT, 55 °C) for 2, 4, and 6 min. The control group received no treatment (NT). Cleaning efficiency was assessed through rheological analysis, weight measurement, transparency evaluation, SEM imaging, 3D geometry evaluation, stress relaxation, and cell viability tests. Results showed increased temperature and longer centrifugation times significantly reduced aligner viscosity, weight (P < 0.05), and transmittance. IPA-cleaned aligners exhibited significantly lower transparency and rougher surfaces in SEM images. All groups met ISO biocompatibility standards in cytotoxicity tests. The NT group had higher root mean square (RMS) values, indicating greater deviation from the original design. Stress relaxation tests revealed over 95% recovery in all groups after 60 min. The findings suggest that a 2-min HT centrifugation process effectively removes uncured resin without significantly impacting the aligners' physical and optical properties, making it a clinically viable option.


Asunto(s)
Centrifugación , Impresión Tridimensional , Temperatura , Resinas Sintéticas/química , Poliuretanos/química , Supervivencia Celular/efectos de los fármacos , Ensayo de Materiales , Humanos , Animales
9.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 42(3): 353-358, 2024 Jun 01.
Artículo en Inglés, Chino | MEDLINE | ID: mdl-39049656

RESUMEN

OBJECTIVES: This work aimed to evaluate the effect of artificial aging on the translucency and color difference (ΔE) of ultra-translucent zirconia and provide a reference for clinical application. METHODS: The discs of ultra-translucent zirconia from six brands (Wieland, 3M ESPE, Amann Girrbach, Kuraray Noritake, Upcera, and Besmile) were cut and sintered according to each manufacturer's product instructions; the experimental groups were named ZNT, LVP, AG, KAT, UPC, and BSM, respectively. IPS e.max Press was used as the control group (PLT). The specimens (n=6) were prepared with a diameter of 14 mm and a thickness of 1 mm. The specimens were subjected to artificial aging treatment according to the following conditions: in an autoclave at 134 ℃ at 0.2 MPa for 4, 8, and 12 h. According to the CIE1976Lab system, the CIE L*, a*, and b* values of the specimens before and after aging were measured by a co-lorimeter. The translucency parameter (TP) and ΔE were calculated. RESULTS: The mean TP values of each group before aging inorder were PLT>KAT>AG>ZNT>BSM>UPC>LVP. We found no significant difference in translucency in all experimental groups after aging for 4 and 8 h compared with those before aging. After 12 h of aging, the TP values of the KAT and ZNT groups were not significantly different from those before aging, but the TP values of the AG, BSM, LVP, and UPC groups were significantly lower than those before aging (P<0.05). The TP value of the control group was significantly higher than that of the other experimental groups at different stages (P<0.05). ΔE=3.3 was considered the visible color difference, and ΔE was less than 3.3 in all groups after 4 h of aging. After aging for 8 h, ΔE of the UPC group was slightly higher than 3.3. ΔE of the BSM and UPC groups was greater than 3.3 after 12 h of aging. CONCLUSIONS: The TP and ΔE of different brands of ultra-translucent zirconia may change after various aging times. The translucency of some zirconia showed a decreasing trend and the color difference showed an increasing trend with the aging time.


Asunto(s)
Cerámica , Ensayo de Materiales , Circonio , Color , Propiedades de Superficie
10.
BMC Oral Health ; 24(1): 821, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39033129

RESUMEN

OBJECTIVE: The aim of our study was to measure the color changes in one-shade composite resins when exposed to common drinks, such as tea, cola and coffee. MATERIALS/METHODS: In our study, Omnichroma, Vitrra APS Unique, GC A'chord and Charisma Diamond One composite resins were used. Composite resins were placed in stainless steel molds with depths of 2 mm and diameters of 5 mm. Ten specimens were immersed in tea, 10 specimens were immersed in coffee, 10 specimens were immersed in cola and 10 specimens were immersed in distilled water in an incubator at 37 °C for 14 days. Color measurements were performed at the beginning of the study and after 24 h and 14 days. Color values ​​were measured using a CIE L*a*b* system with a spectrophotometer device. Color and translucency changes were calculated and data analyzed using one-way ANOVA, two-way ANOVA, and post-hoc Tukey test (p < 0.05). RESULTS: The greatest color changes occurred in the tea and coffee groups; the smallest color change occurred in the control group. After 14 days, the greatest color change was observed in the Charisma + Coffee group; the smallest color change was observed in the Omnichroma + Water group. The transparency and contrast ratios changed in all groups, and the smallest change occurred in the Omnichroma control group. CONCLUSION: Significant differences were found in the composite color changes after immersion in beverages. The color variations significantly differed depending on the beverage in which the specimens were immersed. The initial contrast ratio was markedly different from the examined materials. CLINICAL SIGNIFICANCE: The study emphasizes the significance of common beverages on the color stability of one-shade composite resins, underlining the need of appropriate material selection for long-term aesthetic effects in one-shade composite resin restorations.


Asunto(s)
Café , Color , Resinas Compuestas , Ensayo de Materiales , , Resinas Compuestas/química , Espectrofotometría , Bebidas , Humanos , Bebidas Gaseosas , Factores de Tiempo , Cola/química , Agua/química , Propiedades de Superficie
11.
J Clin Ultrasound ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39082319

RESUMEN

OBJECTIVES: To evaluate the prevalence of chromosomal anomalies in fetuses affected by increased nuchal translucency(iNT >99Th centile), cystic hygroma (CH) and cases progressing to fetal hydrops (NIHF) in order to correlate this result to prognosis and perinatal fetal outcomes, improving patient's counseling. METHODS: From January 2020 to December 2023, first trimester screening according to FMF criteria were performed in "Maternal fetal medicine Unit" of Foggia's hospital. We studied and collected clinical data of fetuses affected by nuchal translucency >99th centile (iNT), CH and cases progressing to Fetal Hydrops (non-immune fetal hydrop, NIFH). In these selected cases, we evaluated fetal Karyotype to demonstrate the presence of chromosomal abnormalities, associated to fetal structural anomalies and different pregnancy outcome. RESULTS: We have evaluated 45 cases of iNT, CH, and NIFH, identified by ultrasound during first trimester screening. Of these 45 pregnant women, four were lost to follow-up. Of the 41 pregnancies, 20 cases (48.8%) delivered at our division with newborns discharged in good health. Of the 21 patients (51.2%) who miscarried, only two miscarried spontaneously; the other 19 decided on a medical termination of pregnancy (MTP). The 19 patients who decided for MTP showed genetic abnormalities and/or malformation. The 20 cases of fetuses discharged as healthy newborns were enrolled with the following diagnoses: 5 had a diagnosis of CH (20% of cases), 1 case of NIFH (5% of cases), and 14 of iNT (75% of cases). All these fetuses had a normal karyotype and no major malformations. CONCLUSIONS: Isolated CH diagnosis is more frequent than described in Literature (5 cases out of 12: 41.7%) and their prognosis are better than previously described, with the same outcomes of fetuses with iNT without associated anomalies. The possibility of early diagnosis of chromosomal anomalies, associated malformations or the evolution into hydrops is essential for a complete consultation.

12.
Dent Mater J ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085143

RESUMEN

This study evaluated fracture resistance of monolithic fixed dental prostheses (FDPs) fabricated using different placement strategies of various connector designs in multilayered zirconia disc. Monolithic FDPs were placed in translucent and dentin layers of multilayered zirconia disc and fabricated with V-shaped and U-shaped connector designs gained by sharp and blunt millings. The FDPs were cemented on abutment models made of polymer material, underwent thermal cycles, and loaded to fracture using the universal testing machine. Fracture loads and modes were analyzed using two-way ANOVA, Tukey's post hoc test, and Fisher exact test (p≤0.05). The chosen placement strategy and connector designs gained by different milling procedures in computer-aided design/computer-aided manufacturing technology affect fracture resistance of monolithic FDPs made of multilayered zirconia materials. Placing the connector in translucent layer rather than dentin layer of multilayered zirconia disc and using sharp milling significantly reduces fracture resistance of monolithic multilayered zirconia FDPs.

13.
J Dent ; 147: 105129, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38878814

RESUMEN

OBJECTIVES: To assess the translucency of machinable and printable ceramic-glass polymer materials with different thicknesses. METHODS: Five ceramic-glass polymer materials were tested: one 3D-printable material, Permanent Crown resin (3D), two machinable materials available at low translucency (LT) and high translucency (HT) levels, VITA Enamic (VE) HT/LT, and Cerasmart 270 (CS) HT/LT. A total of 100 specimens were produced across 10 subgroups (n = 10) with thicknesses of 1 mm and 1.5 mm. The colour coordinates of the specimens were measured against black and white backgrounds using a spectrophotometer. Translucency was quantified using the Relative Translucency Parameter (RTP), calculated via the CIEDE2000 formula. A two-way ANOVA followed by post-hoc tests with Bonferroni correction (α = 0.05) was used for statistical analysis. RESULTS: The RTP for both thicknesses were ranked as follows: CSHT > VEHT > CSLT > 3D > VELT. The RTP of the 3D was lower than that of the HT machinable materials (CSHT and VEHT) for both thicknesses (p < 0.05). No significant difference was observed between the RTP of 3D and CSLT at 1.5 mm (p = 1.000); however, at 1 mm, the RTP of the 3D was lower than that of the CSLT (p < 0.05). Notably, the 3D showed the least translucency difference with a 0.5 mm increase in thickness. CONCLUSIONS: Printable ceramic-glass polymer materials demonstrated lower translucency than HT machinable ceramic-glass polymer materials. Both the thickness and type significantly influenced the translucency of the LT machinable counterparts compared to the printable ceramic-glass polymer material. CLINICAL SIGNIFICANCE: Printable ceramic-glass polymer resins may be a suitable option for minimally invasive procedures, especially when attempting to mask undesirable-coloured abutments. When selecting HT machinable ceramic-glass polymers, clinicians should pay greater attention to the abutment colour and thickness of the restorative material.


Asunto(s)
Cerámica , Materiales Dentales , Vidrio , Ensayo de Materiales , Polímeros , Espectrofotometría , Cerámica/química , Polímeros/química , Materiales Dentales/química , Vidrio/química , Impresión Tridimensional , Color , Humanos , Propiedades de Superficie , Luz , Porcelana Dental/química
14.
J Clin Med ; 13(12)2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38930153

RESUMEN

Background: This study assesses the effects of the 'Radiant' image enhancement technique on fetal nuchal translucency (NT) measurements during first-trimester sonographic exams. Methods: A retrospective analysis of 263 ultrasound images of first-trimester midsagittal sections was conducted. NT measurements were obtained using a semi-automatic tool. Statistical methods were applied to compare NT measurements with and without 'Radiant' enhancement. An in vitro setup with predefined line distances provided additional data. Results: Incremental increases in NT measurements were observed with varying levels of 'Radiant' application: an average increase of 0.19 mm with 'Radiant min', 0.24 mm with 'Radiant mid', and 0.30 mm with 'Radiant max.' The in vitro results supported these findings, showing consistent effects on line thickness and measurement accuracy, with the smallest mean deviation occurring at the 'Radiant mid' setting. Conclusions: 'Radiant' image enhancement leads to significant increases in NT measurements. To avoid systematic biases in clinical assessments, it is advisable to disable 'Radiant' during NT measurement procedures. Further studies are necessary to corroborate these findings and to consider updates to the NT reference tables based on this technology.

15.
Cureus ; 16(5): e61246, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939276

RESUMEN

INTRODUCTION: Prenatal screening tests are essential for preventing common genetic disorders, yet their acceptability among pregnant women in India remains unexplored. This study aims to investigate the acceptability of prenatal screening tests and their correlation with demographic characteristics among pregnant women in India. METHODS: A cross-sectional study was conducted at a tertiary care, public hospital, involving 200 pregnant women. Data were collected through a self-administered questionnaire assessing demographic information and the acceptability of prenatal screening tests. Statistical analysis included chi-square tests and logistic regression. RESULTS: Most participants demonstrated adequate acceptability toward prenatal screening tests, with 73% scoring above the threshold. Factors associated with higher acceptability included younger maternal age, second-trimester gestational age, higher education, salaried employment, and urban residence. However, factors such as parity, consanguinity, mode of conception, and family history of genetic disease showed no significant associations. CONCLUSION: The study highlights positive attitudes toward prenatal screening tests among pregnant women in India, particularly among younger, more educated, and urban populations. These findings emphasize the need for targeted interventions to enhance awareness and accessibility of prenatal screening, ultimately contributing to the reduction of the genetic disorder burden in India.

16.
Dent Mater J ; 43(4): 525-530, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38825450

RESUMEN

This study aimed to propose the measurement methods for resin composite translucency using four shades of resin composite and four spectrophotometers. Four methods were used for measuring translucency: (A) color measurement using reflectance mode, (B) visible light spectrum measurement using reflectance mode, (C) color measurement using transmittance mode, (D) visible light spectrum measurement using transmittance mode. Although there was a significant difference among the results of the translucency measuring methods, the same tendency was observed for translucency parameters obtained using each spectrophotometer. Therefore, the four methods can potentially be used as translucency measuring methods for resin composite.


Asunto(s)
Color , Resinas Compuestas , Ensayo de Materiales , Espectrofotometría , Resinas Compuestas/química , Materiales Dentales/química
17.
BMC Oral Health ; 24(1): 660, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38840111

RESUMEN

BACKGROUND: Effects of ceramic translucency, layer thickness, and substrate colour on the shade of lithium disilicate glass-ceramic restorations proved to be significant in several studies, however, quantitative, numerical results on the relationship between the colour difference and these parameters are still lacking. The purpose of this in vitro study was to quantitatively determine how the colour reproduction ability of a lithium disilicate glass-ceramic is affected by its translucency, layer thickness, and substrate colour. METHODS: Ceramic samples were prepared from A2 shade IPS e.max CAD blocks with high and low translucencies (HT and LT) in a thickness range of 0.5-2.5 mm (+/- 0.05 mm). Layered samples were acquired utilizing composite substrates in 9 shades; transparent try-in paste was used. The spectral reflectance of the specimens was assessed under D65 standard illumination with a Konica Minolta CM-3720d spectrophotometer. The CIEDE2000 colour difference (ΔE00) between two samples was analysed using perceptibility and acceptability thresholds set at 50:50%. Statistical analysis involved linear regression analysis and the Kruskal-Wallis test. RESULTS: An increase in the thickness of 0.5 mm reduced the ΔE00 of the HT samples to 72.8%, and that of the T samples to 71.1% (p < 0.0001). 7 substrates with HT and LT specimens had significantly different results from the mean (p < 0.05). A thickness of 0.5 mm is not sufficient to achieve an acceptable result at any level of translucency, while the low translucency ceramic at a thickness of 1.5 mm gave acceptable results, except for severely discoloured substrates (ND8 and ND9). CONCLUSIONS: The colour reproduction ability of lithium disilicate glass-ceramics is significantly affected by their translucency, layer thickness, and 7 substrates out of 9 substrates examined.


Asunto(s)
Cerámica , Color , Porcelana Dental , Porcelana Dental/química , Cerámica/química , Coloración de Prótesis , Espectrofotometría , Ensayo de Materiales , Humanos , Propiedades de Superficie
18.
J Prosthodont ; 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38734933

RESUMEN

PURPOSE: To evaluate the effect of different printing orientations and post-polymerization time with thermal cycling on the translucency of 3D-printed denture base resins. METHODS: Heat-polymerized (HP) acrylic resin specimens were fabricated and 3D-printed denture base materials (NextDent, ASIGA, FormLabs) were printed with different printing orientations (0, 45, 90 degrees) and subjected to different post-polymerization times (15-, 30-, 60-, and 90-min). All specimens were polished and immersed in distilled water for 1 day at 37°C. CIEDE2000 was used to measure the translucency parameters (TP00) before and after thermal cycling (5000 cycles) recording the color parameters (L*, a*, b*) against a black and white background using a spectrophotometer. k-factors ANOVA followed by post hoc Tukey's test (α = .05) was performed for statistical analysis. RESULTS: The k-factors ANOVA test showed a significant effect of resin material, post-polymerization time, and printing orientation on translucency (p < 0.001). In comparison to HP, all 3D-printed resins showed lower translucency with all post-polymerization times and printing orientation (p < 0.001) except FormLabs resin (p > 0.05). For all 3D-printed resins, the translucency increased, with increasing the post-polymerization time (p < 0.001) and 60- and 90-min showed the highest translucency. For printing orientation, 90 and 45 degrees significantly showed high translucency in comparison to 0 degrees (p < 0.001). FormLabs showed significantly higher translucency when compared with NextDent and ASIGA per respective printing orientation and post-polymerization time. The translucency significantly decreased after thermal cycling for all tested resins (p < 0.001). CONCLUSION: The findings of this study demonstrated that the translucency of 3D-printed resins is influenced by the printing orientation, post-polymerization time, and resin type. As a result, choosing a resin type, and printing orientation, with a longer post-polymerization time should be considered since it may improve the esthetic appearance of the 3D-printed resins.

19.
Med Pharm Rep ; 97(2): 205-214, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38746037

RESUMEN

Background and aims: Dental veneers have become increasingly required among patients, but little is known about the optical properties of veneers obtained from the same ceramic material through different processing techniques. Methods: In this study we compared the translucency and the opalescence parameters of zirconia-reinforced lithium silicate (ZLS) veneers restorations fabricated through CAD/CAM milling and hot-pressing techniques on the upper central incisor. Eighty specimens divided into 8 groups (n=10) were sectioned (Celtra Duo) and heat pressed (Celtra Press) to obtain 0.8 mm thickness. The optical parameters were calculated from the color difference against different backgrounds. Analysis of variance, one way ANOVA and post-hoc multiple comparison tests were used to evaluate and compare the optical properties of the same material, with a significance level of p < 0.05. Results: The processing method had significant effect on optical parameters. Celtra Duo HT proved to be the material with the highest transparency degree. The hot-pressing technique led to higher opacity than CAD/CAM milling technique. Conclusions: For a bio-mimetic aesthetic prosthetic restoration, the ceramic materials must have the same translucency and opacity as the real tooth. The results of this study revealed that high translucency ZLS obtained through hot pressing technique was the material of choice, as it fulfilled these requirements.

20.
Fetal Diagn Ther ; : 1-10, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38815555

RESUMEN

INTRODUCTION: This study aimed to evaluate the occurrence of clinically relevant (sub)microscopic chromosomal aberrations in fetuses with the nuchal translucency (NT) range from 3.0 to 3.4 mm, which would be potentially missed by cfDNA testing. METHODS: A retrospective data analysis of 271 fetuses with NT between 3.0 and 3.4 mm and increased first trimester combined test (CT) risk in five cohorts of pregnant women referred for invasive testing and chromosomal microarray was performed. RESULTS: A chromosomal aberration was identified in 18.8% fetuses (1:5; 51/271). In 15% (41/271) of cases, trisomy 21, 18, or 13 were found. In 0.7% (2/271) of cases, sex chromosome aneuploidy was found. In 1.1% (3/271) of cases, CNV >10 Mb was detected, which would potentially also be detected by genome-wide cfDNA testing. The residual risk for missing a submicroscopic chromosome aberration in the presented cohorts is 1.8% (1:54; 5/271). CONCLUSION: Our results indicate that a significant number of fetuses with increased CT risk and presenting NT of 3.0-3.4 mm carry a clinically relevant chromosomal abnormality other than common trisomy. Invasive testing should be offered, and counseling on NIPT should include the test limitations that may result in NIPT false-negative results in a substantial percentage of fetuses.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA