RESUMEN
ABSTRACT Coloured compounds (anthocyanins) in açaí can stain resin-modified glass-ionomer cement (RMGIC) due to its low staining resistance. Aim The aim of this study was to assess whether açaí compromises the surface colour and roughness of RMGIC in vitro. Materials and Method Disc-shaped specimens (2 mm thick, 8 mm in diameter) of Vitremer™ (3M ESPE, St Paul, MN, USA) were prepared according to the manufacturer 's instructions. The mixture was inserted into a silicone mouldplaced between two mylar strips, and light cured. Specimens were randomly divided into three groups (n=25) according to the solutions to be used for chemical degradation: artificial saliva (control), açaí sorbet and açaí juice. A spectrophotometer CM-2600d/2500d (Konica Minolta, Tokyo, Japan) was used to analyse the colour (CIELa*b* scale). Surface roughness (Ra, mm) was measuredusing theprofilometer Surfcorder SE 1700 (Kosaka Corp, Tokyo, Japan). The specimens were subjected to three daily soaks (6 ml, 15 minutes) for 14 days at 37°C. They were washed in distilled water and placed in fresh saliva (30 minutes in the interval). After the third soak in a day, they were stored in fresh saliva overnight. Outcomes were analysed at baseline (L*, a*, b*, Ra) and after degradation (L'*, a'*, b'*, Ra'). Results The pH values of saliva, sorbet, and juice were 7.0, 3.8, and 4.9, respectively. ΔE* values were 6.6 for saliva, 6.9 for sorbet and 7.8 for juice. There was a significant ΔE* difference between saliva (p=0.005) and juice (p=0.002), and between juice and sorbet (p=0.019), but none between saliva and sorbet (p=0.401). There was no significant Δb* difference between the solutions. No difference between juice and sorbet was observed for Δa*, but they were significantly different from saliva (p<0.001). Brightness (L*) changed significantly. Juice showed the highest ΔE* (7.8) and ΔL* (7.7). No significant change was observed for roughness and there was no difference between the solutions for ARa. Conclusions Açaí and saliva led to unacceptable staining, but no significant roughness changes in the resin-modified glass-ionomer cement.
RESUMO As antocianinas presentes no açaí podem manchar o cimento de ionomero de vidro modificado por resina (CIVMR) devido a baixa resistencia ao manchamento do material. Objetivo O objetivo desse estudo foi avaliar se o açaí compromete a cor e a rugosidade de superficie de um CIVMR in vitro. Materials e Método Amostras (2 mm de espessura, 8 mm de diámetro) de Vitremer™ (3M ESPE, St Paul, MN, USA) foram preparadas de acordo com as instrugoes do fabricante. O materialfoi espatulado, inserido em um molde de silicone colocado entre duas tiras de poliestireno e fotopolimerizado. Após, as amostras foram randomizadas e alocadas em tres grupos (n=25) de acordo com as solugoes usadas para a degradagao química: saliva artificial (controle) e sorbet de açaí e suco de açaí. Utilizou-se o espectrofotometro CM-2600d/2500d (Konica Minolta, Tokyo, Japan) para a análise da cor (escala CIELa*b*) e o rugosímetro Surfcorder SE 1700 (Kosaka Corp, Tokyo, Japan) para a rugosidade de superficie (Ra, mm). As amostras foram submetidas a tres imersoes diárias (6 ml, 15 minutos) em cada solugao por 14 dias a 37°C, tendo sido lavadas em água destilada e mantidas em saliva fresca (30 minutos) nos intervalos. Após a terceira imersao no dia, as amostras foram mantidas em saliva renovada até o dia seguinte. As variáveis foram analisadas antes (L*, a*, b*, Ra) e depois da degradagao química (L'*, a'*, b'*, Ra'). Resultados Os valores de pH da saliva, sorbet e suco foram, respectivamente 7,0, 3,8 e 4,9. Houve diferenga significante para ΔE* entre saliva (p=0.005) e suco (p=0.002) e entre suco e sorbet (p=0.019), mas nao entre saliva e sorbet (p=0.401). Nao foi observada diferenga significante para Δb* entre as solugoes. Nao houve diferenga significante para Δa* entre suco e sorbet, mas eles foram significativamente diferentes da saliva (p<0.001). A luminosidade (L*) mostrou alteragao significante. O suco mostrou os maiores valores de ΔE* (7,8) e ΔL* (7,7)". Nao houve mudanga significante para a rugosidade e nao foi observada diferenga significante entre as solugoes para ARa (p>0.05). Conclusao O açaí e a saliva causaram manchamento inaceitável do glaze do CIVMR e insignificante alteragao da rugosidade.
RESUMEN
Este estudo investigou a eficácia biomecânica de infraestruturas de próteses feitas de cobalto-cromo (CoCr) e compósito de fibra de vidro (FVRC), implantadas em mandíbulas edêntulas. A distribuição de densidade foi investigada utilizando um modelo ósseo sintético, equipado com extensômetros, para simular condições anatômicas e biomecânicas humanas. Os implantes de conexão interna cone morse fabricados pela Conexão Sistemas de Próteses, Arujá, São Paulo, Brasil, têm diâmetro e comprimento de 4.0mm e 13mm, respectivamente, e os intermediários protéticos selecionados foram Micro Unit Sólidos da mesma marca para plataforma cone morse, com altura de transmucoso 2,5 mm, foram utilizados para suportar as infraestruturas de próteses híbridas. Por meio de extensometria, mediu-se a deformação óssea sob carga ao redor dos quatro implantes, comparando as performances das infraestruturas CoCr e FVRC. Os resultados revelaram informações importantes sobre a seleção de materiais para infraestruturas de próteses, com foco especiÌfico nas barras de FVRC e CoCr. Os testes "in vitro" e análises estatiÌsticas destacaram que as barras de FVRC produziram menores microdeformações em comparação com as de CoCr sob carga. Essa diferença foi estatisticamente significativa, indicando que a FVRC possui uma capacidade superior de absorver e distribuir carga de maneira mais eficiente. No entanto, ressalta-se a necessidade de estudos futuros, incluindo pesquisas clínicas, para explorar totalmente as implicações desses achados e aprimorar ainda mais as práticas de reabilitação oral com implantes (AU)
This study investigated the biomechanical effectiveness of prosthetic infrastructures made of cobalt-chromium (CoCr) and fiberglass composite (FGC), implanted in edentulous jaws. The density distribution was investigated using a synthetic bone model, equipped with strain gauges, to simulate human anatomical and biomechanical conditions. The morse cone internal connection implants manufactured by Conexão Sistemas de Próteses, Arujá, São Paulo, Brazil, have a length of 4.0mm and 13mm, respectively, and the prosthetic intermediates selected were Micro Unit Solids of the same brand for a morse cone platform, with a transmucosal height of 2.5 mm, were used to support hybrid prosthetic infrastructures. Using extensometry, bone deformation under load around the four implants was measured, comparing with the performance of the CoCr and FGC infrastructures. The results revealed important information about the selection of materials for prosthetic infrastructures, with a specific focus on FGC and CoCr bars. "In vitro" tests and statistical analyzes highlighted that FGC bars produced smaller microdeformations compared to CoCr bars under load. This difference was statistically significant, demonstrating that FGC has a superior capacity to absorb and distribute load more efficiently. However, the need for future studies, including clinical research, is highlighted to fully explore the implications of these findings and further improve oral rehabilitation practices with implants. (AU)
Asunto(s)
Moldes Quirúrgicos , Aleaciones de CromoRESUMEN
Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)
Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)
Asunto(s)
Materiales Dentales , Pins DentalesRESUMEN
Objective: This study aimed to evaluate the optical behavior of pressable lithia-silicate and lithia-zirconia-silicate glass ceramics toward additional heat treatment protocols. Material and Methods: 40 lithia-silicate discs (15mm x 1mm) were heat pressed following the manufacturers' instructions. Discs were divided into four groups (n=10) according to type as follows: two groups of lithia-silicate-glass ceramics; Gp(E) (IPS e.max Press; Ivoclar Vivadent AG), Gp(L) (GC Initial LiSi Press, GC), two lithia-zirconia-silicate pressable glass ceramics; Gp(C) (Celtra Press, Dentsply Sirona) and Gp(A) (VITA Ambria, VITA Zahnfabrik). Each group was subdivided into (n=5): Subgroup(T1): the thermal tempering temperature was set 9% below the pressing temperature, Subgroup(T2): the temperature was set 5% below the pressing temperature. Optical properties: color, translucency parameter (TP), and contrast ratio (CR) were evaluated by spectrophotometer (Aglient Cary 5000 UV-VisNIR) after pressing and after thermal tempering. Results: Thermal tempering regardless of temperature resulted in a color shift within the acceptability level as ΔE for Gp(E) (3.18±2) followed by ΔE for Gp(L) (2.47±0.19) by ΔE for Gp(C) (2.26±0.14) and the last ΔE for Gp(A) (1.62±0.13). Subgroup(T2) showed a significantly higher color shift with mean ΔE(2.55±0.63) compared to Subgroup(T1) ΔE(2.35±0.59). There was a statistically significant increase in TP after tempering for all tested groups parallelled with a decrease in CR values. Conclusion: Heat tempering of the tested lithia-silicate pressable ceramics had a significant effect on the optical outcome of these materials, being lithia-zirconia-silicate ceramics more stable and less affected optically than other lithia-silicate-glass ceramics.(AU)
Objetivo: Avaliar o comportamento óptico de cerâmicas pressionáveis de vidro de litia-silicato e litia-zircônia-silicato sob protocolos adicionais de tratamento térmico. Materiais e métodos: 40 discos de litia-silicato (15mm x 1mm) foram prensados a quente conforme instruções dos fabricantes. Material e Métodos: 40 discos de litia-silicato (15mm x 1mm) foram prensados e divididos em quatro grupos (n=10): dois de lithia-silicato-vidro, Gp(E) (IPS e.max Imprensa) e Gp(L) (GC inicial LiSi Press), e dois de vidro prensado de litia-zircônia-silicato, Gp(C) (Celtra Press) e Gp(A) (VITA Ambria). Cada grupo foi subdividido em (n=5): Subgrupo(T1): amostras temperadas a 9% abaixo da temperatura de prensagem, e Subgrupo(T2): a temperatura foi ajustada 5% abaixo da temperatura de prensagem. As propriedades ópticas, incluindo cor, translucidez (TP) e contraste (CR), foram avaliadas com um espectrofotômetro (Aglient Cary 5000 UV-Vis-NIR) após prensagem e temperagem térmica. Resultados: O tratamento térmico resultou em mudança de cor dentro do nível aceitável, com ΔE mais alto para Gp(E) (3,18±2), seguido por Gp(L) (2,47±0,19), Gp(C) (2,26±0,14), e Gp(A) (1,62±0,13). No subgrupo (T2), houve uma mudança de cor mais significativa, com ΔE médio de (2,55±0,63), comparado ao subgrupo (T1) com ΔE médio de (2,35±0,59). Houve aumento significativo na TP e redução nos valores de RC após o tratamento térmico em todos os grupos testados. Conclusão: O tratamento térmico das cerâmicas prensadas de litia-silicato teve um efeito significativo na sua qualidade ótica, com as cerâmicas de litia-zircônia-silicato mostrando-se mais estáveis e menos afetadas visualmente em comparação com outras cerâmicas de litia-silicato-vidro(AU)
Asunto(s)
Silicatos , Materiales Dentales , CalorRESUMEN
Este trabalho teve como objetivo demonstrar a importância do Tratamento Restaurador Atraumático (ART) na Odontologia, assim como compreender sua contextualização histórica, descrever suas vantagens e desvantagens, conhecer suas indicações e limitações e seu protocolo. Foram selecionados artigos científicos publicados em português e inglês, disponíveis nas bases de dados MEDLINE, SciELO e Google Acadêmico, tendo sido incluídos artigos dos últimos dez anos, utilizando os descritores: "Tratamento Dentário Restaurador sem Trauma", "Cárie dentária", "Cimento de Ionômero de Vidro" e "Avaliação da Promoção de Saúde". O tratamento restaurador Atraumático (ART), consiste na empregabilidade de uma técnica que tem como finalidade combater a doença cárie e promover saúde. Resume-se em uma abordagem de gerenciamento para lesões de cárie com mínimos preparos, sendo utilizados apenas instrumentos manuais para remoção da dentina infectada, a exemplo a colher de dentina, sendo finalizada posteriormente com cimento de ionômero de vidro para selar a cavidade. As principais vantagens estão relacionadas a sua aplicação, sendo pregada como uma técnica de fácil execução, procedimento rápido, apresenta baixo custo, devido à necessidade mínima de materiais que são utilizados, dispensa a utilização da energia elétrica, pode ser feita em diversos ambientes. Diante da literatura compreende-se que ART é uma técnica de grande importância para o gerenciamento e declínio da doença cárie em diversos âmbitos odontológico, capaz de proporcionar grandes vantagens positiva para abordagem odontológica, tornando o atendimento menos estressante, mais colaborativo e rápido.
This study aimed to demonstrate the importance of Atraumatic Restorative Treatment (ART) in Dentistry, as well as to understand its historical context, describe its advantages and disadvantages, know its indications and limitations and its protocol. Scientific articles published in Portuguese and English, available in the MEDLINE, SciELO and Google Scholar databases were selected, including articles from the last ten years, using the descriptors: "Restorative Dental Treatment without Trauma", "Dental Caries", "Glass Ionomer Cement" and "Evaluation of Health Promotion". The Atraumatic Restorative Treatment (ART) consists of the employability of a technique that aims to combat caries and promote health. It is summarized in a management approach for caries lesions with minimal preparations, using only manual instruments to remove the infected dentin, such as the dentin spoon, being finished later with glass ionomer cement to seal the cavity. The main advantages are related to its application, being preached as a technique of easy execution, quick procedure, low cost, due to the minimum need for materials that are used, it does not require the use of electricity, it can be performed in different environments. In view of the literature, it is understood that ART is a technique of great importance for the management and decline of caries in various dental areas, capable of providing great positive advantages for the dental approach, making care less stressful, more collaborative and faster.
Asunto(s)
Caries Dental , Tratamiento Restaurativo Atraumático Dental , Cementos de Ionómero VítreoRESUMEN
As lesões dentárias traumáticas são um problema de saúde pública mundial, dentre as quais a fratura dentária é a de maior ocorrência, envolvendo principalmente os dentes anteriores. A abordagem de grandes fraturas anteriores é um desafio para cirurgiões dentistas de qualquer nível pois, além da função, afetam diretamente a estética do paciente, fazendo-se necessário um planejamento que envolva diferentes especialidades na odontologia. Objetivo: Relatar um caso clínico de reabilitação funcional e estética de fratura dentária nos incisivos centrais superiores envolvendo tratamento endodôntico, instalação de pino de fibra de vidro e restauração direta em resina composta. Relato de Caso: O paciente de 17 anos sofreu fratura nos incisivos centrais superiores causada por uma queda de bicicleta. Devido à busca tardia por tratamento o elemento 21 foi diagnosticado com necrose pulpar e, portanto, foi submetido à tratamento endodôntico pela Técnica Crown Down e reabilitação com pino de fibra de vidro Splendor-SAP. Posteriormente, os elementos 11 e 21 foram restaurados com facetas diretas em resina composta pela técnica incremental. Conclusão: A reabilitação com instalação de pino de fibra de vidro associada à técnica de estratificação incremental em resina composta se mostra como uma boa opção para reabilitação estética pois permite dar forma anatômica ao dente com riqueza de detalhes na estratificação da dentina e esmalte, além de máxima preservação da estrutura dental. Os resultados obtidos reforçam o sucesso estético e funcional com significativo impacto na qualidade de vida do paciente(AU)
Traumatic dental injuries are a worldwide public health problem, among which dental fractures are the most frequent, mainly involving the anterior teeth. The approach of large anterior fractures is a challenge for dental surgeons of any level because, in addition to function, they directly affect the patient's esthetics, requiring a plan that involves different specialties in dentistry. Objective: Report a clinical case of functional and aesthetic rehabilitation of dental fractures in maxillary central incisors involving endodontic treatment, installation of a fiberglass post and direct restoration in composite resin. Case Report: The 17-year-old patient suffered a fracture in the upper central incisors caused by a fall from a bicycle. Due to the late search for treatment, element 21 was diagnosed with pulp necrosis and, therefore, underwent endodontic treatment using the Crown Down Technique and rehabilitation with a Splendor-SAP fiberglass pin. Later, elements 11 and 21 were restored with direct veneers in composite resin using the incremental technique. Conclusion: Rehabilitation with the installation of a fiberglass post associated with the incremental layering technique in composite resin is a good option for aesthetic rehabilitation as it allows the anatomical shape of the tooth with rich details in the layering of dentin and enamel, in addition to maximum preservation of the tooth structure. The results obtained reinforce the aesthetic and functional success with a significant impact on the patient's quality of life(AU)
Asunto(s)
Humanos , Masculino , Adolescente , Traumatismos de los Dientes , Resinas Compuestas , Restauración Dental Permanente , Estética Dental , Calidad de Vida , Tratamiento del Conducto Radicular , Necrosis de la Pulpa Dental , Coronas con Frente Estético , IncisivoRESUMEN
Introduction: Cerebral Palsy (CP) is characterized by a disorder of posture and movement, commonly leading to disabling orthopedic alterations, including muscle shortening, especially in the lower limbs. Stretching methods, performed gradually, are necessary to delay the impairment in function from muscle shortening. The use of serial casting aims to promote proper alignment, and an ideal and stable support base, in addition to better bone and joint health, leading to better posture, mobility, muscle function, and, subsequently, increased fitness and health.Objective: evaluate range of motion, postural control, and motor performance in children with CP, using serial casting, as well as to measure its effect on fitness through the autonomic nervous system (ANS).Methods: Sixty children and adolescents with CP, of both sexes, 3 to 12 years of age, will be divided into three groups: Groups A, B, and C, with 20 individuals each. Group A will use serial casting, Group B will use the orthosis continuously (with removal only allowed for bathing), and Group C will use the orthosis in their daily routine. Range of motion of the ankle of first and second resistance levels (R1 and R2), gross motor function measure (GMFM), and balance (measured by BERG scale) will be used in the initial and final assessments, and after 6 months and one year of follow-up. Timed-up-and-go (TUG), load distribution (baropodometry), motor performance measured through a real basketball game and the virtual MoveHero game, analysis of body angulation with "mydartfish", and cardiac autonomic modulation through heart rate variability will be assessed in three different situations: barefoot, with orthosis, and with casting.Conclusion: Serial casting demonstrates the potential to produce positive results in the treatment of individuals with CP regarding better alignment, with consequent motor and autonomic improvement.
RESUMEN
O objetivo deste trabalho foi avaliar, ex vivo, pelo teste de compressão e ciclagem, a resistência a fratura de dentes que tiveram suas raízes fragilizadas em laboratório que receberam reforço intrarradicular com um modelo de pino de fibra de vidro Splendor-SAP em comparação ao pino de fibra de vidro Exacto. Além disso, foi realizada análise por elementos finitos para identificar os pontos de maior estresse estrutural. Foram utilizadas 60 raízes de dentes bovinos, os espécimes foram seccionados e padronizados com 16 mm de comprimento. Os canais foram instrumentados em toda a sua extensão utilizando limas endodônticas manuais. As amostras foram aleatoriamente distribuídas em seis grupos acordo com a espessura do remanescente radicular medidos a partir do terço cervical (2 mm e 3 mm) e o reforço radicular a ser utilizado (n=10): G1 - Controle 1, com remanescente radicular de 2 mm e sem reforço intrarradicular; G2 - Controle 2, com remanescente radicular de 3 mm e sem reforço intrarradicular; G3 - Com remanescente de 2 mm e reforço intrarradicular utilizando pino Exacto; G4 - Com remanescente radicular de 3 mm e reforço intrarradicular utilizando Exacto; G5 - Com remanescente radicular de 2 mm e reforço intrarradicular utilizando Splendor-SAP; G6 - Com remanescente radicular de 3 mm e reforço intrarradicular utilizando Splendor-SAP. Para a fragilização simulada, o desgaste radicular foi de 12 mm no interior do canal. Em seguida, os canais foram obturados e o material obturador removido dos terços cervical e médio, restando apenas 4 mm de material no terço apical. A cimentação dos pinos foi realizada seguindo o protocolo do fabricante. O teste de fadiga foi realizado por ciclagem mecânica dos espécimes para o envelhecimento das mesmas (1200000 ciclos; 3.8 Hz; carga = 88 N). Foi realizado o teste de compressão pela máquina de Ensaios Universais, com célula de carga de 100 Kg à velocidade de 1 mm/min com incidência a 45°. Os valores médios de resistência à fratura encontrados para os grupos, em ordem crescente, foram: G1 - 9,045 kgf, G2 - 9,753 kgf, G3 - 68,411 kgf, G4 - 80,167 kgf, G5 - 70,551 e G6 - 80,027. Os espécimes foram analisados em estereomicroscópio para classificação do modo de falha. Os resultados obtidos foram submetidos à análise estatística (ANOVA e Tukey) que demonstrou diferença estatisticamente significativa (p<0,05) (AU)
The objective of this work was to evaluate, ex vivo, by compression and cycling test, the resistance to fracture of teeth that had their roots weakened in the laboratory and that received intraradicular reinforcement with a Splendor-SAP fiberglass post model in comparison to the Exact fiberglass pin. In addition, finite element analysis was performed to identify the points of greatest structural stress. Sixty roots of bovine teeth were used, the specimens were sectioned and standardized with 16mm in length. The canals were instrumented along their entire length using manual endodontic files. The samples were randomly distributed into six groups according to the thickness of the root remnant (2 mm and 3 mm) and the root reinforcement to be used (n=10): G1 - Control 1, with a 2 mm root remnant and without intraradicular reinforcement ; G2 - Control 2, with root remnant of 3 mm and without intraradicular reinforcement; G3 - With a 2 mm remnant and intraradicular reinforcement using an Exacto post; G4 - With root remnant of 3 mm and intraradicular reinforcement using Exacto; G5 - With root remnant of 2 mm and intraradicular reinforcement using Splendor-SAP; G6 - With root remnant of 3 mm and intraradicular reinforcement using Splendor-SAP. For simulated embrittlement, root wear was 12 mm inside the canal. Then, the specimens were obturated and had the obturator material removed from the cervical and middle thirds, leaving only 4 mm of material in the apical third. The cementation of the posts was performed following the manufacturer's protocol. The fatigue test was carried out by mechanical cycling of the specimens for their aging (1200000 cycles; 3.8 Hz; load = 88 N). The compression test was carried out using the Universal Testing machine, with a load of 100 kg at a speed of 1 mm/min with an incidence of 45°. The average fracture resistance values found for the groups, in ascending order, were: G1 - 9,045 kgf, G2 - 9,753 kgf, G3 - 68,411 kgf, G4 - 80,167 kgf, G5 - 70,551 e G6 - 80,027. The specimens were analyzed under a stereomicroscope to classify the failure mode. The results obtained were submitted to statistical analysis (ANOVA and Tukey) which showed a statistically significant difference (p <0.05). (AU)
Asunto(s)
Análisis de Varianza , Análisis de Elementos Finitos , Pins Dentales , Resistencia FlexionalRESUMEN
O objetivo deste estudo foi analisar a resistência de união de restaurações indiretas cimentadas em superfícies dentinárias desmineralizadas com simulação da remoção seletiva da dentina com e sem uso de material forrador. Foram utilizados 60 dentes bovinos com a superfície vestibular desgastada até dentina sadia e divididos em quatro grupos: dentina sadia (controle), dentina desmineralizada (des), dentina desmineralizada e selada com resina flow (des-flow) e dentina desmineralizada e coberta com cimento de inonômero de vidro (des-civ). Todos os espécimes receberam condicionamento com ácido fosfórico (37% Condac, FGM) previamente a hibridização com adesivo universal (Single Bond Universal; 3M). O grupo des-civ recebeu uma cobertura de cimento de ionômero de vidro previamente ao condicionamento e hibridização e o grupo des-flow recebeu um selamento com resina flow (Resina Filtek Z350 XT Supreme Flowable, 3M) após condicionamento e hibridização. Em sequência, foram cimentadas peças simulando restaurações indiretas em resina composta (Grandioso VOCO) na região condicionada de cada amostra. O conjunto recebeu fotoativação por 60 segundos em cada face da peça cimentada. Após 48 horas da cimentação, os espécimes dos três primeiros grupos foram submetidos aos testes mecânicos de tração, com velocidade de 1 mm/min. E após 29 dias, o quarto grupo foi submetido ao mesmo teste. A análise do tipo de fratura foi realizada por estereomicroscopia e os dados foram convertidos em MPa. Os resultados apresentaram diferença estatística de acordo com o teste ANOVA a 1 fator (p=0,011). Para as comparações múltiplas, o teste de Tukey apontou que o grupo des-flow apresentou valores menores do que o grupo controle. Todas as outras comparações foram similares. Concluiu-se que o grupo des-flow, quando comparado ao grupo controle, apresentou uma adesão inferior e que os materiais forradores não diferiram entre si (AU)
The aim of this study was to analyze the bond strength of cemented indirect restorations on demineralized dentin surfaces by simulating selective dentin removal with and without the use of a liner material. Sixty bovine teeth were used with the buccal surface worn down to healthy dentin and divided into four groups: healthy dentin (control), demineralized dentin (des), demineralized dentin sealed with flow resin (desflow) and demineralized dentin covered with glass ionomer cement (des-civ). All specimens were etched with phosphoric acid (37% Condac, FGM) prior to hybridization with universal adhesive (Single Bond Universal; 3M). The des-civ group received a glass ionomer cement cover prior to etching and hybridization, and the desflow group received a flowable resin seal (Filtek Z350 XT Supreme Flowable Resin, 3M) after etching and hybridization. Subsequently, specimens simulating indirect composite resin restorations (Grandioso - VOCO) were cemented in the etched region of each sample. The set was photoactivated for 60 seconds on each side. 48 hours after cementation, the specimens from the first three groups were subjected to mechanical tensile testing at a speed of 1 mm/min. After 29 days, the fourth group was subjected to the same test. The analysis of the fracture type was performed by stereomicroscopy and the data were converted into MPa. The results showed statistical difference according to the one-way ANOVA (p=0.011). For multiple comparisons, the Tukey's test showed that the des-flow group presented lower values than the control group. All other comparisons were similar. It was concluded that the des-flow group, when compared to the control group, presented lower adhesion and that the liner materials did not differ among themselves.(AU)
Asunto(s)
Animales , Bovinos , Resinas Compuestas , Cementos de Ionómero VítreoRESUMEN
O avanço no campo da engenharia tecidual e biomateriais conduz ao aprimoramento dos tratamentos e tecnologias já existentes, visando otimizar a resolução de injúrias e permitir tratamentos cada vez mais eficientes para a população. Desta maneira, o objetivo deste estudo foi produzir e caracterizar scaffolds de policaprolactona (PCL) incorporadas com três formulações diferentes de vidro bioativo, bem como avaliar a influência destas na osteogênese in vitro e na neoformação óssea in vivo. Para isso, foram obtidos quatro grupos experimentais: PCL (P), PCL incorporado com o vidro bioativo 45S5 (P45), PCL incorporado com o vidro bioativo S53P4 (P53) e PCL incorporado com o vidro bioativo 58S (P58). A síntese de todos os vidros foi realizada pela rota Sol-Gel, os quais foram incorporados à solução de PCL previamente à produção dos scaffolds por meio do processo de eletrofiação. Posteriormente à caracterização morfológica e físico-química, os scaffolds foram submetidas aos testes biológicos in vitro e in vivo. Na etapa in vitro, células da medula óssea obtidas de fêmures de ratos foram isoladas e plaqueadas com os scaffolds, visando avaliar a influência destas na atividade e diferenciação celular na osteogênese. Para o ensaio in vivo, 30 ratos Wistar foram submetidos ao procedimento cirúrgico para confecção de um defeito crítico de 3,0 mm nas tíbias direita e esquerda para avaliação dos scaffolds. A eutanásia dos animais foi realizada após 4 semanas do procedimento cirúrgico, e as peças foram submetidas à análise histológica, imuno-histoquímica (IHC), histomorfométrica e ao teste biomecânico de flexão de três pontos. Os dados obtidos foram estatisticamente analisados pelo teste ANOVA um fator, com nível de significância adotado de 5%. A caracterização morfológica e físico-química evidenciou o sucesso da referida metodologia em confeccionar o novo biomaterial. Na análise in vitro, observou-se que os scaffolds não foram citotóxicos, e permitiram atividade e diferenciação celular, sendo que o grupo P exibiu maior conteúdo de proteína total (p<0,05) em ambos os períodos analisados, e os grupos P53 e P58 exibiram maior atividade de fosfatase alcalina (ALP), não diferindo entre si (p>0,0001) enquanto P exibiu menor atividade, diferindo estatisticamente (p<0,05). Todos os grupos permitiram a formação de nódulos de mineralização, e foi observado maior quantificação de Alizarina nos grupos P45, P53 e P58 quando comparados ao grupo P (p<0,05). Na análise histológica foi observada a presença de neoformação óssea na região do defeito crítico em todos os grupos. A IHC evidenciou a imunomarcação por osteocalcina (OC) e TRAP. Na análise histomorfométrica foi observada maior formação nos grupos P45 e P53, os quais não diferiram entre si (p>0,0001). O teste biomecânico evidenciou que não houve diferença estatisticamente significante entre os grupos (p>0,05) ao avaliar a força de ruptura das tíbias. Os resultados evidenciaram o sucesso na produção do novo compósito, sendo que os grupos contendo vidro bioativo, em especial o grupo P53, se mostraram mais osteoativos e osteocondutores quando comparado ao grupo P, e evidenciam o potencial uso na engenharia tecidual.(AU)
Advancements in the field of tissue engineering and biomaterials lead to the enhancement of existing treatments and technologies, aiming to optimize injury resolution and enable increasingly efficient treatments for the population. Thus, the objective of this study was to produce and characterize polycaprolactone (PCL) scaffolds incorporated with three different formulations of bioactive glass, as well as to evaluate their influence on in vitro osteogenesis and in vivo bone neoformation. To achieve this, four experimental groups were established: PCL (P), PCL incorporated with 45S5 bioactive glass (P45), PCL incorporated with S53P4 bioactive glass (P53), and PCL incorporated with 58S bioactive glass (P58). The synthesis of all glasses was carried out via the Sol-Gel route, and they were subsequently integrated into the PCL solution prior to scaffold production through the electrospinning process. Following morphological and physicochemical characterization, the scaffolds underwent in vitro and in vivo biological testing. In the in vitro phase, bone marrow cells obtained from rat femurs were isolated and plated with the scaffolds to assess their influence on cellular activity and differentiation in osteogenesis. For the in vivo assay, 30 Wistar rats underwent a surgical procedure to create a 3.0 mm critical defect in the right and left tibias for the evaluation of the scaffolds. Euthanasia of the animals was performed after 4 weeks of the surgical procedure, and the specimens were subjected to histological analysis, immunohistochemistry (IHC), histomorphometric analysis, and a three-point bending biomechanical test. The data obtained were statistically analyzed using a one-way ANOVA with a significance level set at 5%. Morphological and physicochemical characterization confirmed the success of the aforementioned methodology in fabricating the new biomaterial. In the in vitro analysis, it was observed that the scaffolds were not cytotoxic and allowed for cellular activity and differentiation. Group P exhibited a higher total protein content (p<0.05) in both analyzed periods, and groups P53 and P58 displayed greater alkaline phosphatase (ALP) activity, with no significant difference between them (p>0.0001), while P exhibited lower activity, differing statistically (p<0.05). All groups supported the formation of mineralization nodules, with a higher quantification of Alizarin observed in the P45, P53, and P58 groups compared to the P group (p<0.05). Histological analysis revealed the presence of bone neoformation in the critical defect region in all groups. IHC showed immunolabeling for osteocalcin (OC) and TRAP. Histomorphometric analysis revealed greater formation in the P45 and P53 groups, which did not differ from each other (p>0.0001). The biomechanical test indicated no statistically significant difference between the groups (p>0.05) when evaluating tibial rupture strength. The results demonstrated the success in producing the new composite, with the bioactive glass-containing groups, especially the P53 group, showing greater osteoactivity and osteoconductivity compared to the P group, highlighting their potential for use in tissue engineering (AU)
Asunto(s)
Osteogénesis , Materiales Biocompatibles , Regeneración Ósea , Ingeniería de Tejidos , NanofibrasRESUMEN
Objetivos: Avaliar as propriedades mecânicas, atividade antimicrobiana e citocompatibilidade da zircônia translúcida 5Y-PSZ revestida por vidros experimentais contendo boro e prata. Métodos: Discos 5Y-PSZ (KATANA UTML™, Kuraray Noritake) foram processados e divididos em quatro grupos: polido, sem nenhum revestimento (Controle), aplicação de glaze comercial (Glaze) e vidros experimentais contendo prata (AgCoat) e boro (BCoat). As amostras foram submetidas aos testes de dureza Vickers, testes de flexão biaxial, análise fractográfica e rugosidade através de perfilometria óptica. O potencial antimicrobiano foi caracterizado usando biofilmes de espécie única de Streptococcus mutans e Candida albicans. Foi realizada a quantificação de unidades viáveis formadoras de colônias (UFC), atividade metabólica (CV), ensaios de matriz polissacarídica extracelular (EPS) e biovolume. Biofilmes foram visualizados por microscópio eletrônico de varredura (MEV) e microscopia confocal de varredura a laser (CLSM). A citocompatibilidade foi determinada usando os testes WST-1 e LIVE&DEAD usando células-tronco do ligamento periodontal (PDLSCs) por 24 h. Todas as caracterizações biológicas foram realizadas em triplicatas técnicas e biológicas usando amostras independentes. As análises estatísticas foram realizadas por ANOVA de uma via, teste de Tukey, análise de Weibull e análise de correlação de Pearson. Resultados: BCoat, AgCoat e Glaze alcançaram dureza semelhante, que foi menor que o Controle. BCoat teve a maior resistência à flexão e parâmetros de Weibull (m = 11,5, sF 625 MPa, s0 620) seguido por AgCoat (m = 5,3; sF 464 MPa, s0 478 MPa). BCoat diminuiu significativamente a formação de biofilmes, conforme mostrado pela menor UFC (5,94 log-UFC/mm2) e atividade metabólica (0,17 a.u.) em comparação com os outros grupos (AgCoat: 6,44 log-UFC/mm2, 0,89 a.u.; Glaze: 6,81 log UFC/mm2, 1,21 a.u.; Controle: 6,82 logUFC/mm2, 1,25 a.u.). BCoat e AgCoat apresentaram os menores valores de EPS (0,11 a.u.), seguidos por Glaze e Controle (0,13 a.u.; 0,14 a.u., respectivamente). MEV e CLSM revelaram que os biofilmes no BCoat eram finos, esparsos, com menor biovolume, enquanto os outros grupos produziram biofilmes robustos com maior biovolume. Os ensaios de viabilidade celular não mostraram toxicidade para PDLSCs para todos os grupos. Conclusão: 5Y-PSZ revestida por vidro experimental contendo boro surge como uma estratégia potencial para melhorar as propriedades mecânicas e antimicrobianas do material (AU).
Objectives: To evaluate the mechanical and antimicrobial properties of boroncontaining coating on translucent zirconia (5Y-PSZ). Methods: 5Y-PSZ discs (Control) were coated with a glaze (Glaze), silver- (AgCoat), or boron-containing (BCoat) glasses. The coatings' antimicrobial potential was characterized using S. mutans and C. albicans biofilms through viable colony-forming units (CFU), metabolic activity (CV), and the extracellular polysaccharide matrix (EPS). Biofilm architectures were imaged under scanning electron and confocal laser scanning microscopies (SEM and CLSM). Cytocompatibility was determined at 24 h via WST-1 and LIVE&DEAD assays using periodontal ligament stem cells (PDLSCs). The coatings' effects on mechanical properties were characterized by Vickers hardness, biaxial bending tests, and fractography analysis. Statistical analyses were performed via one-way ANOVA, Tukey's tests, Weibull analysis, and Pearson's correlation analysis. Results: BCoat significantly decreased biofilm formation, having the lowest CFU and metabolic activity compared with the other groups. BCoat and AgCoat presented the lowest EPS, followed by Glaze and Control. SEM and CLSM images revealed that the biofilms on BCoat were thin and sparse, with lower biovolume. In contrast, the other groups all yielded similarly robust biofilms with higher biovolume without compromising PDLSC viability. BCoat, AgCoat, and Glaze also presented similar hardness significantly lower than Control. BCoat had the highest flexural strength, characteristic strength and Weibull parameters (sF : 625 MPa; s0: 620 MPa; m = 11.5), followed by AgCoat (sF : 464 MPa; s0: 478 MPa; m = 5.3). Significance: BCoat is a cytocompatible glass with promising antimicrobial properties that can improve the mechanisms and reliability of 5Y-PSZ (AU).
Asunto(s)
Fracaso de la Restauración Dental , Placa Dental , Ciencia de los Materiales , Resistencia FlexionalRESUMEN
ABSTRACT The aim of this study was to report the clinical case of an 8-year-old male patient seen at the Pediatric Dentistry outpatient clinic at the Universidade Federal do Paraná, Brazil, diagnosed with molar-incisor hypomineralization (MIH) after presenting with pain in teeth 16, 36, and 46, which had extensive atypical cavities and opacities on the adjacent enamel. A diagnostic wax-up of affected teeth was performed for manufacture of silicone occlusal matrix. Encapsulated high-viscosity glass ionomer cement was handled and inserted into the occlusal matrix which was fitted onto the teeth by slight finger pressure. After setting time, excess of material was removed, and occlusion was checked. A flowable resin coating material was applied, and the restorations were finished. Six months later, the restorations performed for treatment of the severe MIH lesions proved to be efficient, lowering the sensitivity reported by the patient, reshaping the teeth, improving their function, and refining dental esthetics.
RESUMO O objetivo deste estudo foi relatar um caso clínico de um paciente com diagnóstico de Hipomineralização de Molares e Incisivos (HMI). Paciente do sexo masculino, de 8 anos de idade, compareceu à clínica de Odontopediatria da Universidade Federal do Paraná com queixa de dor nos dentes 16, 36 e 46 - os quais apresentavam extensas cavitações atípicas com opacidades no esmalte adjacente. O enceramento diagnóstico dos dentes afetados foi realizado para a confecção das matrizes oclusais de silicone. Cimento ionômero de vidro de alta viscosidade encapsulado foi manipulado e inserido na matriz oclusal, a qual foi encaixada sobre os dentes, exercendo-se leve pressão digital. Após a presa do material os excessos foram removidos e a oclusão foi checada. Aplicou-se uma camada de resina fluída de cobertura e as restaurações foram finalizadas. Após seis meses, as restaurações realizadas para tratar as lesões severas de HMI mostraram-se eficazes, reduzindo a sensibilidade relatada pelo paciente, além de reestabelecerem a anatomia, função e estética dentária.
RESUMEN
ABSTRACT Objective: Evaluating the clinical results of bioactive glass S53P4 putty for the treatment of cavitary chronic osteomyelitis. Methods: Retrospective observational study, including patients of any age with clinical and radiological diagnosis of chronic osteomyelitis, who underwent surgical debridement and implantation of bioactive glass S53P4 putty (BonAlive® Putty, Turku, Finland). Patients who underwent any plastic surgery on the soft tissues of the affected site or had segmental bone lesions or septic arthritis were excluded. Statistical analysis was performed using Excel®. Demographic data, as well as data on the lesion, treatment, and follow-up, were collected. Outcomes were classified as "disease-free survival," "failure," or "indefinite." Results: This study included 31 patients, of which 71% were men and had with a mean age of 53.6 years (SD ± 24.2). In total, 84% were followed-up for at least 12 months and 67.7% had comorbidities. We prescribed combination antibiotic therapy for 64.5% of patients. In 47.1%, Staphylococcus aureus was isolated. Finally, we classified 90.3% of cases as "disease-free survival" and 9.7% as "indefinite." Conclusion: Bioactive glass S53P4 putty is safe and effective to treat cavitary chronic osteomyelitis, including infections by resistant pathogens, such as methicillin-resistant S. aureus. Level of Evidence IV, Case Series.
RESUMO Objetivo: Avaliar a atividade do vidro bioativo S53P4 em pasta no tratamento de osteomielite crônica. Métodos: Estudo observacional retrospectivo, com inclusão de indivíduos de qualquer idade com diagnóstico clínico e radiológico de osteomielite que realizaram tratamento cirúrgico com limpeza e desbridamento, seguido do preenchimento da cavidade com biovidro S53P4 em pasta (BonAlive ® Putty, Turku, Finland). Foram excluídos pacientes submetidos a procedimentos de cirurgia plástica nos tecidos moles do local afetado, com lesões ósseas segmentares e com presença de artrite séptica. A análise estatística foi realizada em Excel ® . Foram coletados dados demográficos, sobre a lesão, o tratamento e o acompanhamento. O desfecho foi classificado em "sobrevida livre de doença", "falha" ou "indeterminado". Resultados: Dos 31 pacientes analisados, 71% eram homens, com idade média de 53,6 anos (DP ± 24,26). Do total, 84% foram acompanhados por no mínimo 12 meses, e 67,7% apresentaram comorbidades. A terapia antibiótica combinada foi realizada em 64,5% dos pacientes, sendo o patógeno mais frequente o Staphylococcus aureus (47,1%). Ao final, 90,3% dos pacientes obtiveram "sobrevida livre de doenças" e 9,7% foram considerados "indeterminados". Conclusão: O vidro bioativo S53P4 em pasta é seguro e eficaz no tratamento da osteomielite cavitária e de infecções por patógenos resistentes, incluindo o S. aureus multirresistente. Nível de Evidência IV, Série de Casos.
RESUMEN
Statement of problem: the bond strength between adhesive cement and root dentin can be affected by irrigation protocols. Purpose: therefore, the objective of this systematic review was to answer the following question: Do irrigation solutions used during root canal instrumentation influence the adhesion of glass fiber posts to root dentin? Material and Methods: this study followed the recommendations of PRISMA 2020 for writing. PubMed, Scopus, Web of Science, and LILACS databases were searched for articles published until 26 January, 2022. Grey literature and a manual search were also performed. The inclusion criteria were based on the PICO strategy: permanent human or animal teeth (P), which were irrigated during root canal instrumentation with endodontic substances (I) and compared to irrigation with sodium hypochlorite at various concentrations (C) to analyze the bond strength of glass fiber posts (O). Two authors independently performed data extraction and the risk of bias. Results: eight articles were included. Four articles were classified as having a high risk of bias, where the others as medium risk. Studies have reported conflicting results regarding the influence of irrigating solutions and the different concentrations of sodium hypochlorite on the adhesion of glass fiber posts to root dentin. Conclusion: the heterogeneity between studies did not allow the conclusion of a true estimate regarding this topic, and further well-designed studies are needed to clarify this issue. Register: CRD42020221835. (AU)
Definição do problema: a resistência de união entre o cimento adesivo e a dentina radicular pode ser afetada pelos protocolos de irrigação. Objetivo: portanto, o objetivo desta revisão sistemática foi responder à seguinte questão: As soluções de irrigação usadas durante a instrumentação do canal radicular influenciam a adesão de pinos de fibra de vidro à dentina radicular? Material e Métodos: este estudo seguiu as recomendações do PRISMA 2020 para sua redação. As bases de dados PubMed, Scopus, Web of Science e LILACS foram pesquisadas para artigos publicados até 26 de janeiro de 2022. A literatura cinza e uma pesquisa manual também foram realizadas. Os critérios de inclusão foram baseados na estratégia PICO: dentes humanos ou animais permanentes (P), que foram irrigados durante a instrumentação do canal radicular com substâncias endodônticas (I) e comparados à irrigação com hipoclorito de sódio em várias concentrações (C) para analisar a resistência de união de pinos de fibra de vidro (O). Dois autores realizaram independentemente a extração de dados e o risco de viés. Resultados:oito artigos foram incluídos. Quatro artigos foram classificados como de alto riscode viés, enquanto os demais como de médio risco. Estudos relataram resultados conflitantes sobre a influência de soluções irrigadoras e as diferentes concentrações de hipoclorito de sódio na adesão de pinos de fibra de vidro à dentina radicular. Conclusão: a heterogeneidade entre os estudos não permitiu a conclusão de uma estimativa verdadeira sobre este tópico, sendo necessários mais estudos bem delineados para esclarecer esta questão. Registo: CRD42020221835 (AU)
Asunto(s)
Irrigantes del Conducto Radicular , Moldes Quirúrgicos , Resistencia al Corte , DentinaRESUMEN
O objetivo deste estudo foi desenvolver e avaliar um adesivo resinoso modificado com a incorporação de partículas de vidro bioativas (SCHOTT Bioactive Glass) em diferentes concentrações. Foram avaliados a resistência ao cisalhamento (RU), o índice de remanescente dentário (IRA), o grau de conversão (GC) e a liberação de cálcio. Foram utilizados 50 incisivos bovinos que foram fixados, através de suas raízes, em um molde de PVC, com resina acrílica autopolimerizável. As amostras foram alocadas em 5 grupos (n=10): TXT - Adesivo Transbond XT (3M Unitek, Monrovia, CA, EUA) sem adição de partículas de vidro bioativas, TXT20, TXT30, TXT50 Adesivo Transbond XT acrescido respectivamente de 20%, 30% e 50% de partículas de vidro bioativas e SH - Adesivo resinoso FL BOND ll (SHOFU Inc.) com biomaterial SPRG. As amostras receberam uma profilaxia com pedra pomes e condicionamento com ácido fosfórico à 37%. Em seguida foi aplicada uma fina camada do sistema adesivo indicado na face vestibular dos incisivos bovinos, em todos os grupos e fotopolimerizado por 20 segundos, utilizando-se um fotopolimerizador RADII-Cal (SDI, Victoria, Austrália). Depois foi aplicada uma pequena quantidade de pasta resinosa fotopolimerizável Transbond XT (3M Unitek, Monrovia, CA, EUA) sobre a superfície dos bráquetes autoligados (MORELLI, Sorocaba, São Paulo, Brasil) e estes foram devidamente colados na face vestibular, no centro da coroa clínica do incisivo bovino e fotopolimerizado por 20 segundos, em cada face. Posteriormente as amostras foram submetidas ao teste de resistência ao cisalhamento. O índice de remanescente adesivo foi avaliado em estereomicroscópio DISCOVERY V20 (ZEISS). Os adesivos resinosos foram submetidos ao teste de grau de conversão e liberação de cálcio. Os dados foram inicialmente submetidos ao teste de normalidade e depois submetidos ao teste de ANOVA um fator, seguido do teste de Tukey para análise de comparações múltiplas, com nível de significância de 0,05. De acordo com os resultados obtidos na resistência de união ao cisalhamento (MPa±Dp) a maior média foi observada no grupo TXT 19,50±1,40A, seguida do grupo TXT20 18,22±1,04AB, seguida do grupo SH 17,62±1,45B, seguida do grupo TXT30 14,48±1,46C e a menor média TXT50 14,13±1,02C. No grau de conversão a maior média foi observada no grupo TXT20 73,02±3,33A que foi estatisticamente semelhante ao grupo SH 68,50±1,09A, seguida do grupo TXT 60,28±1,06B e TXT30 58,84±4,06B e a menor média foi do grupo TXT50 40,67±1,21C.Para a liberação de cálcio a maior média foi TXT50 2,23±0,11D, seguida por TXT30 0,74±0,00C, TXT20 0,55±0,00B, SH 0,47±0,04B e TXT 0,14±0,00A. Concluiu-se que a incorporação de partículas de vidro bioativas influenciou na resistência de união ao cisalhamento, no grau de conversão e na liberação de cálcio (AU).
The objective of this study was to develop and evaluate a resin adhesive modified with the incorporation of bioactive glass particles (SCHOTT Bioactive Glass) in different concentrations. Shear bond strength (SBS), adhesive remnant index (ARI), degree of conversion (DC) and calcium release were evaluated. Fifty bovine incisors were used, which were fixed through their roots in a PVC mold with self-curing acrylic resin. The samples were allocated into 5 groups (n=10): TXT Transbond XT Adhesive (3M Unitek, Monrovia, CA, USA) without addition of bioactive glass particles, TXT20, TXT30, TXT50 Transbond XT Adhesive rescpectively increased by 20%, 30% and 50% bioactive glass particles and SH FL BOND ll resin adhesive (SHOFU Inc.) with SPRG biomaterial. The samples received prophylaxis with pumice stoe and conditioning with 37% phosphoric acid. Then, a thin layer of the indicated adhesive system was applied to the buccal surface of the bovine incisors, in all groups, and light cured for 20 seconds, using a RADII-Call curing light (SDI, Victoria, Australia). Then, a small amount of Transbond XT light-curing resinous paste (3M Unitek, Monrovia, CA, USA) was applied on the surface of the self-ligating brackets (MORELLI, Sorocaba, São Paulo, Brazil) and these were duly bonded on the buccal surface, in the center of the clinical crown of the bovine incisor and light cured for 20 seconds, on each side. Subsequently, the samples were submitted to the shear bond test. The adhesive remnant index was evaluated using a DISCOVERY V20 stereomicroscope (ZEISS). The resin adhesives were submitted to the degree of conversion and calcium release test. The data were initially submitted to the normality test and then submitted to the one-way ANOVA test, followed by the Tukey test for analysis of multiple comparisons, with a significance level of 0.05. According to the results obtained in the shear bond strength (MPa±Dp), the highest average was observed in the TXT group 19.50±1.40A, followed by the TXT20 group 18.22±1.04AB, followed by the SH group 17.62±1.45B, followed by the TXT30 group 14.48±1.46C and the lowest mean TXT5014.13±1.02C. In the degree of conversion, the highest average was observed in the TXT20 73.02±3.33A group, wich was statiscally like the SH group 68.50±1.09A, followed by the TXT 60.28±1.06B and TXT30 group 58.84±4.06B and the lowest mean was for the TXT50 group 40.67±1.21C. For calcium release, the highest mean was TXT50 2.23±0.11D, followed by TXT30 0.74±0.00C, TXT20 0.55±0.00B, SH 0.47±0.04B and TXT 0.14±0.00A. It was concluded that the incorporation of bioactive glass particles influenced in the shear bond strength, in the degree of conversion and in the release of calcium (AU).
Asunto(s)
Animales , Bovinos , Ortodoncia , Resistencia al CorteRESUMEN
Atualmente, diversos materiais restauradores encontram-se disponíveis para aplicabilidade em Odontopediatria. Os avanços dos materiais restauradores conduzem à necessidade de novos estudos nessa temática. O presente estudo apresenta duas propostas de investigação: 1) Estudo transversal com objetivo de avaliar a preferência de pais/responsáveis e crianças quanto ao emprego do compômero colorido (Twinky Star®, Voco, Alemanha); 2) Estudo bibliométrico altimétrico com objetivo de analisar 50 artigos mais citados referente aos materiais restauradores utilizados em Odontopediatria e o alcance dessa informação científica nas mídias on-line. O estudo transversal envolveu 260 pares de pais/responsáveis e crianças de 5 a 11 anos de idade de dois serviços de saúde da região metropolitana de Belo Horizonte-MG. Exame quanto à cárie dentária foi realizado por examinadora calibrada para o critério da Organização Mundial da Saúde. Um manequim odontológico contendo restaurações com compômeros coloridos e materiais convencionais (resina composta, ionômero de vidro e amálgama) foi apresentado aos participantes do estudo e realizou-se inquérito sobre a preferência dos materiais dentários. O Questionário de Estilo e Dimensões dos Pais (PSDQ) e o Eysenck Personality Questionnaire Junior (EPQ-J) foram aplicados, este último apenas para pais/responsáveis de crianças de 5 e 6 anos de idade. Análises descritivas, bivariadas e regressão multivariada de Poisson foram realizadas. A maioria dos pais/responsáveis (74,2%) preferiu materiais convencionais. A idade da criança (p=0,006), a renda familiar (p= 0,001) e o nível de escolaridade (p< 0,001) associaram se a essa escolha. A análise multivariada demonstrou que crianças menores de 7 anos apresentaram 1,20 vezes maior probabilidade de escolher compômeros coloridos do que seus pares mais velhos (p< 0,001), assim como pais/responsáveis com menos de 11 anos de escolaridade e cujos filhos eram menores de 7 anos apresentaram 2,17 e 1,74 maior probabilidade para escolher compômeros coloridos, respectivamente. Concluiu-se que responsáveis com maior escolaridade apresentaram maior resistência às restaurações coloridas e crianças menores de 7 anos aceitaram melhor este material. O estudo bibliométrico-altimétrico adotou estratégia de busca em três bases (Web of Science, Scopus e Google Scholar), independente da data de publicação. Após seleção dos artigos por um grupo de cinco pesquisadores, em março de 2023, foram incluídos estudos que avaliassem qualquer material restaurador empregado em dentes decíduos e analisados dados referentes ao título, número de citações, país/continente, autoria, periódico, instituição, desenho do estudo, tipo de material restaurador, e escore altimétrico. Os artigos, publicados entre 1991 a 2002, apresentaram variação de citações de 19 a 113. Os autores com maior número de citações foram Qvist V e Teglers PT. O estudo experimental foi o principal delineamento de estudo observado e o cimento de ionomero de vidro foi o material mais reportado. A Europa foi o continente, e o Brasil, o país com maior número de citações. O escore altimétrico esteve presente em 23 artigos, com ênfase para dois artigos (43/6º e 73/7º). Concluiu-se que o cimento de ionômero de vidro foi o material mais estudado. Ficou evidente o distanciamento entre a posição dos trabalhos nas análises bibliométrica e altimétrica, apontando necessidade de disseminação da informação além dos círculos acadêmicos.
Currently, an arsenal of restorative materials is available for applicability in pediatric dentistry. The advances in restorative materials conducted to need for further studies in this thematic. The present study presents two investigation proposals: 1) Cross-sectional study aiming to evaluate the preference of parents and children regarding the use of colored compomer (Twinky Star®, Voco, Germany); 2) Bibliometric-altmetric study aiming to analyze the 50-most cited papers regarding to restorative materials used in pediatric dentistry and the dissemination of scientific information in online media. The cross-sectional study included 260 pairs of caregivers/children aged 5 to 11, in two public health services, in the metropolitan region of Belo Horizonte-MG. Examination for dental caries was performed by an examiner calibrated to the criteria of the World Health Organization. A dental mannequin containing colored compomers restorations and conventional materials (composite resin, glass ionomer cement and dental amalgam) was presented to the population and a survey was conducted about the preference of dental materials. Parents' Style and Dimensions Questionnaire (PSDQ) and Eysenck Personality Questionnaire Junior (EPQ-J) were applied, the last one only for parents/caregivers of children aged 5 to 6. Descriptive, bivariate and Poisson regression analyzes were performed. Most adults (74.2%) preferred conventional materials. Family income (p= 0.001) and education level (p< 0.001) were associated with its choice. Age up to 7 (p< 0.001) associated with children's choice for colored restorations (72.3%). Children younger than 7 had 1.20 higher probability to choose colored compomers than their older pairs, while adults with children younger than 7 and less than 11 years of schooling had 1.74 and 2.17 higher probability to choose colored compomers, respectively. It was concluded that caregivers with higher educational level showed greater resistance to use of colored restorations and children younger than 7 had better acceptance of colored material. The bibliometrics-altmetrics study adopted a search strategy in three databases (Web of Science, Scopus and Google Scholar), independent of the year of publication. After selection of papers by a panel of five researchers, in March 2023, any restorative material used in deciduous teeth was included and data about the title, number of citations, country/continent, authorship, journal, design of the study, type of restorative material, university and altmetrics score were analyzed. The papers, published between 1991 and 2002, ranged from 19 to 113 citations. The authors with the highest number of citations were Qvist V and Teglers PT. The experimental study was the main study design observed. Analyzing the continent and country with the highest number of citations, Europe highlighted and Brazil was predominant. The altmetric score was present in 23 papers, emphasizing two articles (43/6th and 73/7th). It was concluded that glass ionomer cement was the most studied material. A gap between the position of the papers correlating the bibliometrics and altmetrics analyzes was evident, demonstrating the need to disseminate the information beyond academic circles.
Asunto(s)
Bibliometría , Odontología Pediátrica , Compómeros , Amalgama Dental , Materiales DentalesRESUMEN
Objective: this in vitro study compared the adhesive strengths of the resin sealant with the Giomer technology sealant under salivary contamination. Materials and Methods: fifty-two bovine incisors were randomly divided into four groups (n=13): GI, a resin sealant (Fluroshield®) without salivary contamination (control of GII); GII, Fluroshield sealant + salivary contamination; GIII, a Giomer technology sealant (BeautiSealant®) without salivary contamination (control of GIV); and GIV, BeautiSealant® sealant + salivary contamination. In the salivary contamination groups, artificial saliva was used through a pipette, and after 20 s, it was air-dried and the sealant was applied. Shear strength tests were performed using a universal testing machine. One-way ANOVA variance and Tukey's test were used for multiple comparisons. The fracture types were analyzed using a stereomicroscope with 40X magnification. Results: the means and standard deviations (SD) of adhesion for Fluroshield® and BeautiSealant® in the group without salivary contamination were 15.27 (±0.96) and 11.90 (±0.94), and for the group with salivary contamination, 13.14 (±1.03) and 8.95 (±1.33), respectively, indicating a statistically significant difference between GI and GII p=0.020, GIII and GIV p=0.041. Mixed failures were detected in GI (38%), GII (44%), GIII (38%), and GIV (62%). Conclusion: there was a statistically significant decrease in the adhesive strength values in the groups with salivary contamination for both the sealants studied. However, no significant difference was observed between the two sealants when the materials used were compared.
Objetivo: este estudo in vitro comparou as forças adesivas do selante resinoso com o selante da tecnologia Giomer sob contaminação salivar. Materiais e Métodos: cinquenta e dois incisivos bovinos foram divididos aleatoriamente em quatro grupos (n=13): GI, um selante resinoso (Fluroshield®) sem contaminação salivar (controle do GII); GII, selante Fluroshield + contaminação salivar; GIII, um selante com tecnologia Giomer (BeautiSealant®) sem contaminação salivar (controle do GIV); e GIV, selante BeautiSealant® + contaminação salivar. Nos grupos de contaminação salivar, a saliva artificial foi utilizada por meio de uma pipeta e, após 20 s, foi seca ao ar e aplicado o selante. Os testes de resistência ao cisalhamento foram realizados usando uma máquina de teste universal. A variância ANOVA de uma via e o teste de Tukey foram usados para comparações múltiplas. Os tipos de fratura foram analisados em estereomicroscópio com aumento de 40X. Resultados: as médias e desvios padrão (DP) de adesão para Fluroshield® e BeautiSealant® no grupo sem contaminação salivar foram 15,27 (±0,96) e 11,90 (±0,94), e após contaminação salivar foram 13,14 (±1,03) e 8,95 (±1,33), respectivamente, indicando haver diferença estatisticamente significante entre GI e GII p=0.020, GIII e GIV p=0.041. Falhas mistas foram detectadas em GI (38%), GII (44%), GIII (38%) e GIV (62%). Conclusão: houve diminuição estatisticamente significativa dos valores de resistência adesiva nos grupos com contaminação salivar para ambos os selantes estudados. No entanto, não foi observada diferença significativa entre os dois selantes quando comparados os materiais utilizados.
Asunto(s)
Selladores de Fosas y Fisuras , Saliva Artificial , Resistencia al CorteRESUMEN
ABSTRACT Objective: To identify the diametral tensile strength of Brazilian brands of conventional glass ionomer cements (GIC) when modified powder ratio in their composition compared to each other, and with high viscosity glass ionomer cement for Atraumatic Restorative Treatment (ART). Methods: Experimental study with five groups (n=10 each) and specimens (2.5 mm in height and 5.0 mm in diameter), considering G1 (Maxxion R-MR), G2 (Vidrion R-VR) and G3 Vitro molar (VM-control) according to manufacturer recommending powder/liquid (1:1), G4 (MR) and G5 (VR) plus powder (2:1). The specimens were stored in an oven at 37 ± 1 ° C for 1 day. Diametral Tensile Test was performed by the Instron model 4444. Means differences were tested by Student´s T-Test (α = 5%). Results: There significant differences were in the means (standard deviation) of diametral tensile strength of MR (1:1) 4.24 (±1.47) and MR (2:1), 5.74 (±1.51) (p=0.039) and VR (1:1) 4.50 (±1.27) and VR (2:1) 6.20 (±1.89) (p=0.029). When comparing MR and VR (2:1) with MV (1:1) 4.82 (±1.17), VR 2: 1, 6.20 (±1.89) showed significant differences (p=0.0336). Conclusion: There was a significant increase in the means of diametral tensile strength of Brazilian brands conventional GICs when powder increment, approaching the performance observed by the high viscosity GIC.
RESUMO Objetivo: Identificar a resistência à tração diametral de marcas nacionais de cimentos de ionômero de vidro (CIV) convencionais quando acrescidos de pó em sua composição comparados entre si e com cimento de ionômero de vidro de alta viscosidade para Tratamento Restaurador Atraumático (TRA). Métodos: Pesquisa experimental com cinco grupos (n=10 cada) e confeccionados corpos de prova (2,5 mm de altura e 5,0 mm de diâmetro), considerando G1 (Maxxion R/FGM-MR), G2 (Vidrion R/SS White-VR) e G3 Vitro molar (DFL-VM-controle) manipulados segundo fabricante pó/líquido (1:1), G4 (MR) e G5 (VR) acrescidos de pó (2:1). Os espécimes foram armazenados em estufa a 37 ± 1° C por 1 dia. Teste de Tração Diametral foi realizado pelo equipamento Instron modelo 4444. As diferenças das médias foram testadas pelo Test T de Student (α=5%). Resultados: Foram encontradas diferenças significativas das médias (desvio-padrão) de resistência à tração diametral de MR (1:1) 4,24 (±1,47) e MR (2:1), 5,74(±1,51) (p=0,039) e VR (1:1) 4,50 (±1,27) e VR (2:1) 6,20(± 1,89) (p=0,029). Quando da comparação entre MR e VR (2:1) com VM (1:1) 4,82(±1,17), VR 2:1, 6,20 (±1,89) apresentou média superior e significante (p=0,0336). Conclusão: Observou-se aumento significativo nas médias de resistência mecânica à tração diametral dos CIVs convencionais nacionais a partir do incremento de pó, aproximando-se do desempenho observado pelo CIV de alta viscosidade.
RESUMEN
Introduction: Some experimental models have been used to evaluate the use of biomaterials in bone regeneration. Among them are the critical size defects (CSD) created in rat calvaria. An experimental model has been described in the literature, in which "L" markings are performed on the margins of the bone defects in order to assist in the precise identification of these defects during laboratory processing and analysis of the results. In the proposed model, the "L" markings are filled with amalgam. Objective: The purpose of the present study was to evaluate the amalgam replacement of an experimental bony defect model in rat calvaria by heated or unheated glass ionomer. Material and method: 24 rats were used. A 5 mm CSD was created at each animal calvaria. Two "L" shaped markings were made 2 mm from the margins of the bone defect, filled with amalgam (Group AM), heated glass ionomer cement (Group GIh) or not (Group GI). The animals were euthanized 15 days postoperatively. The areas of the surgical defect and the L-shaped marking were histomorphometrically analyzed and the data were analyzed statistically (p <0.05). Result: There were no significant clinical, histological or methodological differences among the experimental groups. Conclusion: It can be concluded that GI can replace AM in the proposed experimental model and GI heating did not promote additional benefits.
Introdução: Alguns modelos experimentais têm sido usados para avaliar o uso de biomateriais na regeneração óssea. Entre eles estão os defeitos de tamanho crítico (DTC) criados em calvárias de ratos. Um modelo experimental foi descrito na literatura onde marcações em L são realizadas nas margens do defeito ósseo para auxiliar na identificação precisa desses defeitos durante o processamento laboratorial e análise dos resultados. No modelo experimental proposto, as marcações em "L" são preenchidas com amálgama. Objetivo: Avaliar a substituição do amálgama por ionômero de vidro aquecido ou não em um modelo experimental para identificação de defeito ósseo criado em calvária de ratos. Material e método: Foram utilizados 24 ratos. Um DTC de 5 mm de diâmetro foi criado na calvária de cada animal. Duas marcações em "L" foram realizadas a 2 mm das margens do defeito ósseo, preenchidas com amálgama (Grupo AM), ionômero de vidro aquecido (Grupo CIVaq) ou não (Grupo CIV). Os animais foram eutanasiados aos 15 dias pós-operatórios. A área do defeito cirúrgico e das marcações em "L" foram histomorfometricamente avaliadas e os dados estatisticamente analisados (p<0,05). Resultado: Não houve diferença estatisticamente significativa entre os grupos experimentais para as análises metodológicas, clínicas ou histomorfométrica realizadas. Conclusão: Dentro dos limites deste estudo, pode-se concluir que CIV pode substituir o AM no modelo experimental proposto e o aquecimento do CIV não promoveu benefícios adicionais.
Asunto(s)
Ratas , Cráneo , Materiales Biocompatibles , Regeneración Ósea , Amalgama Dental , Cementos de Ionómero Vítreo , Cómputos Matemáticos , Análisis de VarianzaRESUMEN
The current review aimed to compare the mechanical properties and clinical behavior of fiberglass and cast metal posts. It included in-vitro studies, finite element analysis, clinical studies, and systematic reviews that evaluated fiberglass and metal posts with reliable methodologies. The reports in the literature diverge on tooth failure modes and stress distributions in the root according to different posts. Investigations suggest that fiberglass posts are preferable because their elastic modulus is similar to dentin. Other studies mention that the flexibility of fiber posts may damage the interface. The fracture load values of different studies could not be compared. The presence of a ferrule seems beneficial. Cast metal posts provide higher characteristic strength to the set but with more unfavorable failures. Intraradicular posts with a lower elastic modulus produce more stress between the cement layer and dentin. In conclusion, fiberglass and cast metal posts can be used with a ferrule. Cast metal posts seem more appropriate for weakened teeth. The presence of a ferrule benefits the system. Weakened teeth tolerate higher loads when restored with cast metal posts, but when these posts fail, the only solution is tooth extraction. Clinical follow-ups cannot yet detect differences between the survival rates of intraradicular fiberglass and cast metal posts (AU)
O objetivo da presente revisão foi comparar as propriedades mecânicas e o comportamento clínico de pinos de fibra de vidro e núcleos metálicos fundidos. Estudos laboratoriais, analise por elementos finitos, estudos clínicos e revisões sistemáticas que avaliaram pinos de fibra de vidro e metálicos, com metodologia confiável foram selecionados. A literatura mostra-se bastante controversa sobre os modos de falha do dente e a distribuição de tensões na raiz de acordo com diferentes tipos de pinos. Algumas investigações sugerem que pinos de fibra de vidro são preferíveis porque seu módulo de elasticidade é semelhante ao da dentina, enquanto outras mencionam que a flexibilidade do pino de fibra pode ser prejudicial à interface adesiva. Os valores de carga de fratura em diferentes estudos não podem ser comparados. A presença de férula é benéfica. O núcleo metálico fundido resulta em maior resistência característica do conjunto, mas falhas mais desfavoráveis. Também, pinos com menor módulo geram mais tensão entre a camada de cimento e a dentina. Em conclusão, verificou-se que tanto pino de fibra de vidro como núcleo metálico fundido podem ser utilizados quando a férula está presente. Os núcleos metálicos fundidos parecem ser mais indicados para dentes fragilizados. É evidente que a presença de férula é benéfica para o sistema. Dentes fragilizados toleram cargas maiores quando restaurados com núcleos metálicos fundidos; porém, quando falham, a única solução é a extração do dente. Os acompanhamentos clínicos ainda não são capazes de detectar diferença entre as taxas de sobrevivência dos pinos de fibra de vidro e núcleos metálicos (AU)