Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.083
Filtrar
1.
Nanotechnology ; 35(39)2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38955171

RESUMEN

The current work emphasizes the preparation of trimetallic core-shell Ag-TeO2@ZnO nanocomposites (NCs) by thermo-mechanical method for the efficient photocatalytic degradation of 2,4-Dichlorophenol and ß-naphthol pollutants. FE-SEM shows that Ag and TeO2nanoparticles are deposited on the surface of ZnO nanotubes. The band gap of pristine ZnO NPs and 5 wt% Ag-TeO2@ZnO nanocomposites are found to be 3.16 and 2.96 eV, respectively. The calculated specific surface area (SBET) of pristine ZnO NPs and 5 wt% Ag-TeO2@ZnO nanocomposites are 40.47 and 45.66 m2g-1respectively, confirming that Ag and TeO2nanoparticles contribute to increasing in surface area of pure ZnO. The synthesised nanocomposite showed excellent photocatalytic performance for the degradation of ß -naphthol (95.6%) in 40 min at the concentration of (0.6 mg ml-1) and 2,4-DCP (99.6%) in 180 min (0.4 mg ml-1) under natural sunlight. Cyclic Voltammetry and Electrochemical Impedance Spectroscopy were carried out to study the electrochemical properties. The determination of reactive oxygen species (ROS) confirmed that the degradation of the pollutants by 5 wt% Ag-TeO2@ZnO NCs was due to the formation of superoxide radicals. Electron paramagnetic resonance revealed the presence of sharp signals in pure ZnO nanoparticles at g ∼1.95 and oxygen vacancy peak at g ∼2.01 in 5 wt% Ag-TeO2@ZnO NCs. To study the mechanism behind the degradation of pollutants, Scavenger test using histidine and ascorbic acid (ROS scavengers) was performed. The synthesised nanocomposites are highly stable and showed enhanced efficiency up to three cycles, confirming their reusability as a photocatalyst.

2.
Chemistry ; : e202402377, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007521

RESUMEN

Mechanically interlocked molecules are a class of compounds used for controlling directional movement when barriers can be raised and lowered using external stimuli. Applied voltages can turn on redox states to alter electrostatic barriers but their use for directing motion requires knowledge of their impact on the kinetics. Herein, we make the first measurements on the movement of cyclobis(paraquat-p-phenylene) (CBPQT4+) across the radical-cation state of monopyrrolotetrathiafulvalene (MPTTF) in a [2]rotaxane using variable scan-rate electrochemistry. The [2]rotaxane is designed in a way that directs CBPQT4+ to a high-energy co-conformation upon oxidation of MPTTF to either the radical cation (MPTTF•+) or the dication (MPTTF2+). 1H NMR spectroscopic investigations carried out in acetonitrile at 298 K showed direct interconversion to the thermodynamically more stable ground-state co-conformation with CBPQT4+ moving across the oxidized MPTTF2+ electrostatic barrier. The electrochemical studies revealed that interconversion takes place by movement of CBPQT4+ across both the MPTTF•+ (19.3 kcal mol-1) and MPTTF2+ (18.7 kcal mol-1) barriers. The outcome of our studies shows that MPTTF has three accessible redox states that can be used to kinetically control the movement of the ring component in mechanically interlocked molecules.

3.
Mikrochim Acta ; 191(8): 459, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38985347

RESUMEN

A renewable electrochemical screen-printed electrode (SPE) is proposed based on magnetic bamboo-like nitrogen-carbon (N-C) nanotubes loaded with nickel-cobalt alloy (NiCo) nanoparticles (NiCo@N-CNTs) for the determination of ractopamine (RAC). During the preparation of NiCo@N-CNTs, Co-MOF-67 (ZIF-67) was firstly synthesized, and then blended with dicyandiamide and nickel acetate, followed by a one-step pyrolysis procedure to prepare NiCo@N-doped carbon nanotubes. The surface morphology, structure, and chemical composition of NiCo@N-CNTs were characterized by SEM, TEM, XRD, XPS, and EDS. The electrocatalytic and electrochemical behavior of NiCo@N-CNTs were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results demonstrated that NiCo@N-CNTs possessed remarkable conductivity and electrocatalysis to the oxidation of ractopamine (RAC). By using screen-printed electrode (SPE), NiCo@N-CNTs, and a designed base support, a magnetic RAC sensor (NiCo@N-CNTs/SPE) was successfully constructed. It presented a detection linear range of 0.05-80 µM with a detection limit of 12 nM (S/N = 3). It also exhibited good sensitivity, reproducibility, and practicability in spiked real pork samples. Since the adhesion of NiCo/N-CNTs on SPE was controlled by magnet, the NiCo@N-CNTs was easily detached from the SPE surface by magnetism and thus displayed excellent renewability. This work broadened insights into portable devices for on-site and real-time analysis.

4.
Materials (Basel) ; 17(13)2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38998132

RESUMEN

The aim of this paper was to investigate the effect of temperature on the removal efficiency of surfactant-induced interferences. Surfactants were removed as a result of mixing with XAD-7 resin. The study was carried out using the example of Cr(VI) determination by adsorption stripping voltammetry (AdSV). Measurements were carried out using a solution containing Cr(VI), acetate buffer (pH = 6.2), DTPA, KNO3, and different surfactants. Ten mL of the solution was mixed with 0.5 g of XAD-7 resin at different temperatures for 5 min prior to voltammetric measurement. The effect of the mixing temperature of the sample with the resin on the voltammetric Cr(VI) signal in the presence of different surfactants was studied in the range from 20 to 60 °C. The proposed method of removing interference from surfactants by mixing the sample with the XAD-7 resin at 60 °C was used for the determination of trace amounts of Cr(VI) in river water containing non-ionic, anionic, cationic surfactants, and biosurfactants.

5.
Molecules ; 29(13)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38999110

RESUMEN

Electrochemical biosensors have emerged as powerful tools for the ultrasensitive detection of lung cancer biomarkers like carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), and alpha fetoprotein (AFP). This review comprehensively discusses the progress and potential of nanocomposite-based electrochemical biosensors for early lung cancer diagnosis and prognosis. By integrating nanomaterials like graphene, metal nanoparticles, and conducting polymers, these sensors have achieved clinically relevant detection limits in the fg/mL to pg/mL range. We highlight the key role of nanomaterial functionalization in enhancing sensitivity, specificity, and antifouling properties. This review also examines challenges related to reproducibility and clinical translation, emphasizing the need for standardization of fabrication protocols and robust validation studies. With the rapid growth in understanding lung cancer biomarkers and innovations in sensor design, nanocomposite electrochemical biosensors hold immense potential for point-of-care lung cancer screening and personalized therapy guidance. Realizing this goal will require strategic collaboration among material scientists, engineers, and clinicians to address technical and practical hurdles. Overall, this work provides valuable insight for developing next-generation smart diagnostic devices to combat the high mortality of lung cancer.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Técnicas Electroquímicas , Neoplasias Pulmonares , Humanos , Biomarcadores de Tumor/análisis , Neoplasias Pulmonares/diagnóstico , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Antígeno Carcinoembrionario/análisis , Antígeno Carcinoembrionario/sangre , Nanocompuestos/química , Grafito/química
6.
Mikrochim Acta ; 191(8): 456, 2024 07 09.
Artículo en Inglés | MEDLINE | ID: mdl-38980419

RESUMEN

Polydopamine (PDA) has garnered significant interest for applications in biosensors, drug delivery, and tissue engineering. However, similar polycatecholamines like polynorepinephrine (PNE) with additional hydroxyl groups and poly-α-methylnorepinephrine (PAMN) with additional hydroxyl and methyl groups remain unexplored in the biosensing domain. This research introduces three innovative biosensing platforms composed of ternary nanocomposite based on reduced graphene oxide (RGO), gold nanoparticles (Au NPs), and three sister polycatecholamine compounds (PDA, PNE, and PAMN). The study compares and evaluates the performance of the three biosensing systems for the ultrasensitive detection of Mycobacterium tuberculosis (MTB). The formation of the nanocomposites was meticulously examined through UV-Visible, Raman, XRD, and FT-IR studies with FE-SEM and HR-TEM analysis. Cyclic voltammetry and differential pulse voltammetry measurements were also performed to determine the electrochemical characteristics of the modified electrodes. Electrochemical biosensing experiments reveal that the RGO-PDA-Au, RGO-PNE-Au, and RGO-PAMN-Au-based biosensors detected target DNA up to a broad detection range of 0.1 × 10-8 to 0.1 × 10-18 M, with a low detection limit (LOD) of 0.1 × 10-18, 0.1 × 10-16, and 0.1 × 10-17 M, respectively. The bioelectrodes were proved to be highly selective with excellent sensitivities of 3.62 × 10-4 mA M-1 (PDA), 7.08 × 10-4 mA M-1 (PNE), and 6.03 × 10-4 mA M-1 (PAMN). This study pioneers the exploration of two novel mussel-inspired polycatecholamines in biosensors, opening avenues for functional nanocoatings that could drive further advancements in this field.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Oro , Grafito , Indoles , Límite de Detección , Nanopartículas del Metal , Polímeros , Técnicas Biosensibles/métodos , Indoles/química , Polímeros/química , Técnicas Electroquímicas/métodos , Grafito/química , Oro/química , Animales , Nanopartículas del Metal/química , Mycobacterium tuberculosis , Bivalvos/química , Nanocompuestos/química , Electrodos , Norepinefrina/análisis
7.
Mikrochim Acta ; 191(8): 463, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38995455

RESUMEN

The intensifying global opioid crisis, majorly attributed to fentanyl (FT) and its analogs, has necessitated the development of rapid and ultrasensitive remote/on-site FT sensing modalities. However, current approaches for tracking FT exposure through wastewater-based epidemiology (WBE) are unadaptable, time-consuming, and require trained professionals. Toward developing an extended in situ wastewater opioid monitoring system, we have developed a screen-printed electrochemical FT sensor and integrated it with a customized submersible remote sensing probe. The sensor composition and design have been optimized to address the challenges for extended in situ FT monitoring. Specifically, ZIF-8 metal-organic framework (MOF)-derived mesoporous carbon (MPC) nanoparticles (NPs) are incorporated in the screen-printed carbon electrode (SPCE) transducer to improve FT accumulation and its electrocatalytic oxidation. A rapid (10 s) and sensitive square wave voltammetric (SWV) FT detection down to 9.9 µgL-1 is thus achieved in aqueous buffer solution. A protective mixed-matrix membrane (MMM) has been optimized as the anti-fouling sensor coating to mitigate electrode passivation by FT oxidation products and enable long-term, intermittent FT monitoring. The unique MMM, comprising an insulating polyvinyl chloride (PVC) matrix and carboxyl-functionalized multi-walled carbon nanotubes (CNT-COOH) as semiconductive fillers, yielded highly stable FT sensor operation (> 95% normalized response) up to 10 h in domestic wastewater, and up to 4 h in untreated river water. This sensing platform enables wireless data acquisition on a smartphone via Bluetooth. Such effective remote operation of submersible opioid sensing probes could enable stricter surveillance of community water systems toward timely alerts, countermeasures, and legal enforcement.


Asunto(s)
Analgésicos Opioides , Técnicas Electroquímicas , Fentanilo , Estructuras Metalorgánicas , Contaminantes Químicos del Agua , Contaminantes Químicos del Agua/análisis , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Fentanilo/análisis , Fentanilo/sangre , Analgésicos Opioides/análisis , Estructuras Metalorgánicas/química , Electrodos , Aguas Residuales/análisis , Monitoreo del Ambiente/métodos , Límite de Detección , Carbono/química , Nanopartículas/química , Tecnología de Sensores Remotos/métodos
8.
Artículo en Inglés | MEDLINE | ID: mdl-38954330

RESUMEN

Animal farming wastewater is one of the most important sources of ammonia nitrogen (NH4+-N) emissions. Electro-oxidation can be a viable solution for removing NH4+-N in wastewater. Compared with other treatment methods, electro-oxidation has the advantages of i) high removal efficiency, ii) smaller size of treatment facilities, and iii) complete removal of contaminant. In this study, a previously prepared DSA (W, Ti-doped IrO2) was used for electro-oxidation of synthetic mariculture and livestock wastewater. The DSA was tested for chlorine evolution reaction (CER) activity, and the reaction kinetics was investigated. CER current efficiency reaches 60-80% in mariculture wastewater and less than 20% in livestock wastewater. In the absence of NH4+-N, the generation of active chlorine follows zero-order kinetics and its consumption follows first-order kinetics, with cathodic reduction being its main consumption pathway, rather than escape or conversion to ClO3-. Cyclic voltammetry experiments show that NH4+-N in the form of NH3 can be oxidized directly on the anode surface. In addition, the generated active chlorine combines with NH4+-N at a fast rate near the anode, rather than in the bulk solution. In electrolysis experiments, the NH4+-N removal rate in synthetic mariculture wastewater (30-40 mg/L NH4+-N) and livestock wastewater (~ 450 mg/L NH4+-N) is 112.9 g NH4+-N/(m2·d) and 186.5 g NH4+-N/(m2·d), respectively, which is much more efficient than biological treatment. The specific energy consumption (SEC) in synthetic mariculture wastewater is 31.5 kWh/kg NH4+-N, comparable to other modified electro-catalysts reported in the literature. However, in synthetic livestock wastewater, the SEC is as high as 260 kWh/kg NH4+-N, mainly due to the suppression of active chlorine generation by HCO3- and the generation of NO3- as a by-product. Therefore, we conclude that electro-oxidation is suitable for mariculture wastewater treatment, but is not recommended for livestock wastewater. Electrolysis prior to urea hydrolysis may enhance the treatment efficiency in livestock wastewater.

9.
ACS Appl Bio Mater ; 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38978451

RESUMEN

Modulating molecular structure and function at the nanoscale drives innovation across wide-ranging technologies. Electrical control of the bonding of individual DNA base pairs endows DNA with precise nanoscale structural reconfigurability, benefiting efforts in DNA origami and actuation. Here, alloxazine DNA base surrogates were synthesized and incorporated into DNA duplexes to function as a redox-active switch of hydrogen bonding. Circular dichroism (CD) revealed that 24-mer DNA duplexes containing one or two alloxazines exhibited CD spectra and melting transitions similar to DNA with only canonical bases, indicating that the constructs adopt a B-form conformation. However, duplexes were not formed when four or more alloxazines were incorporated into a 24-mer strand. Thiolated duplexes incorporating alloxazines were self-assembled onto multiplexed gold electrodes and probed electrochemically. Square-wave voltammetry (SWV) revealed a substantial reduction peak centered at -0.272 V vs Ag/AgCl reference. Alternating between alloxazine oxidizing and reducing conditions modulated the SWV peak in a manner consistent with the formation and loss of hydrogen bonding, which disrupts the base pair stacking and redox efficiency of the DNA construct. These alternating signals support the assertion that alloxazine can function as a redox-active switch of hydrogen bonding, useful in controlling DNA and bioinspired assemblies.

10.
Environ Res ; 259: 119500, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38950814

RESUMEN

Monitoring fenitrothion (FNT) residues in food and the environment is crucial due to its high environmental toxicity. In this study, we developed a sensitive, reliable electrochemical method for detecting FNT by using screen-printed carbon electrodes (SPCE) modified with porous graphene oxide (PGO) nanosheets. PGO surface properties have been meticulously characterized using advanced spectroscopic techniques. Electrochemical impedance spectroscopy and cyclic voltammetry were used to test the electrochemical properties of the PGO-modified sensor. The PGO-modified sensor exhibited remarkable sensitivity, achieving a detection limit as low as 0.061 µM and a broad linear range of 0.02-250 µM. Enhanced performance is due to PGO's high surface area and excellent electrocatalytic properties, which greatly improved electron transfer. Square wave voltammetry was used to demonstrate the sensor's efficacy as a real-time, on-site monitoring tool for FNT residues in fruit and water. The outstanding performance of the PGO/SPCE sensor underscores its applicability in ensuring food safety and environmental protection.

11.
Sci Rep ; 14(1): 15461, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38965300

RESUMEN

This paper introduces a novel solid-state electrolyte-based enzymatic sensor designed for the detection of acetone, along with an examination of its performance under various surface modifications aimed at optimizing its sensing capabilities. To measure acetone concentrations in both liquid and vapor states, cyclic voltammetry and amperometry techniques were employed, utilizing disposable screen-printed electrodes consisting of a platinum working electrode, a platinum counter electrode, and a silver reference electrode. Four different surface modifications, involving different combinations of Nafion (N) and enzyme (E) layers (N + E; N + E + N; N + N + E; N + N + E + N), were tested to identify the most effective configuration for a sensor that can be used for breath acetone detection. The sensor's essential characteristics, including linearity, sensitivity, reproducibility, and limit of detection, were thoroughly evaluated through a range of experiments spanning concentrations from 1 µM to 25 mM. Changes in acetone concentration were monitored by comparing currents readings at different acetone concentrations. The sensor exhibited high sensitivity, and a linear response to acetone concentration in both liquid and gas phases within the specified concentration range, with correlation coefficients ranging from 0.92 to 0.98. Furthermore, the sensor achieved a rapid response time of 30-50 s and an impressive detection limit as low as 0.03 µM. The results indicated that the sensor exhibited the best linearity, sensitivity, and limit of detection when four layers were employed (N + N + E + N).

12.
Food Chem ; 458: 140296, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38959806

RESUMEN

An effective electrochemical sensor was developed to detect and determine of the As(III) by modifying the carbon paste electrode (CPE) with graphitic carbon nitride decorated with iron-based metal-organic frameworks (Fe-MOF/g-C3N5). The differential pulse anodic stripping voltammetry (DPASV) method was used to analyze As(III) ions in a phosphate buffer solution (0.10 M, pH = 5). Fe-MOF/g-C3N5/CPE showed high sensitivity (4.24 µA µg-1 L), satisfactory linear range (0.50 µg L-1-5.00 µg L-1 and 5.00 µg L-1-30.00 µg L-1), and low detection limit (LOD, 0.013 µg L-1). The prepared sensor was showed an excellent repeatability and selectivity, and successfully used for determination of the As(III) ion in ambient waters and apple juice samples.

13.
Talanta ; 277: 126365, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38964047

RESUMEN

Quantification of trace amounts of iron is of great importance in various fields. In the industrial sector, it is crucial to monitor the release of iron out of corrosion, pickling treatment, and steel manufacturing to address potential environmental and economic challenges. In biological systems, despite its indispensability, it is essential to maintain iron concentration below a specific threshold. Electrochemical (EC) methods provide significant analytical capabilities due to their simplicity, ease of use, and cost-effectiveness. This review focuses on the fundamental principles of EC methods for iron detection, including potentiometry, amperometry, coulometry, voltammetry, and electrochemical impedance spectroscopy (EIS). It further explains the process of obtaining calibration curves, and subsequently, determining the concentration of unknown ions. Additionally, technical notes are presented on selecting the initial signal value, reducing the duration of tests, excluding non-faradaic signals, and extending the linear region with the lowest detection limit. These notes are supported by key findings from relevant case studies.

14.
Mikrochim Acta ; 191(8): 452, 2024 Jul 06.
Artículo en Inglés | MEDLINE | ID: mdl-38970687

RESUMEN

Novel zeolitic imidazolate frameworks (ZIFs), classical subtypes of metal organic frameworks (MOFs), and nanostructures are electro-engineered onto carbon fiber (CF), leading to a unique freestanding electrochemical platform of budlike nano Zn-ZIFs decorated CF (BN-Zn-ZIFs/CF). The unique morphology, structure, and composition are characterized by electron microscopy and energy spectrum analysis. Notably, the BN-Zn-ZIFs/CF platform displays superb electrocatalysis towards the oxidation of isoeugenol with encouragingly low overpotential and high current response. The strong electrocatalytic oxidation capability of BN-Zn-ZIFs/CF makes it an excellent sensing platform for isoeugenol detection. BN-Zn-ZIFs/CF sensor exhibits high-performance isoeugenol sensing with an extremely low limit of detection (13 nM) and wide detection range (0.1-700 µM). Besides, the BN-Zn-ZIFs/CF sensor can greatly resist interference from common ions, major biomolecules, and some amino acids. Moreover, excellent reliability, stability, and practicality are obtained. Our work demonstrates that the as-prepared BN-Zn-ZIFs/CF can act as an high-performance electrochemical sensor for the isoeugenol detection, the well-developed ZIF nanocrystal-modified conductive substrates can be a unique platform for the efficient sensing of other molecules, and the electrochemical engineering strategy can be an effective method for the growing of fresh MOF nanocrystals at conductive substrates in various electrochemical applications.

15.
Biosens Bioelectron ; 262: 116545, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38971040

RESUMEN

Determination of plasma uracil was reported as a method for evaluation of Dihydropyrimidine dehydrogenase (DPD) activity that is highly demanded to ensure the safe administration of 5-fluorouracil (5-FU)-based therapies to cancer patients. This work reports the development of a simple electroanalytical method based on adsorptive stripping square wave voltammetry (AdSWV) at mercury film-coated glassy carbon electrode (MF/GCE) for the highly sensitive determination of uracil in biological fluids that can be used for diagnosis of decreased DPD activity. Due to the formation of the HgII-Uracil complex at the electrode surface, the accuracy of the measurement was not affected by the complicated matrices in biological fluids including human serum, plasma, and urine. The high sensitivity of the developed method results in a low limit of detection (≈1.3 nM) in human plasma samples, falling below the practical cut-off level of 15 ng mL-1 (≈0.14 µM). This threshold concentration is crucial for predicting 5-FU toxicity, as reported in buffer, and ≤1.15% in biological samples), and accuracy (recovery percentage close to 100%).

16.
Mikrochim Acta ; 191(8): 443, 2024 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-38955844

RESUMEN

CoFe@C was first prepared by calcining the precursor of CoFe-metal-organic framework-74 (CoFe-MOF-74), then an electrochemical sensor for the determination of neohesperidin dihydrochalcone (NHDC) was constructed, which was stemmed from the novel CoFe@C/Nafion composite film modified glassy carbon electrode (GCE). The CoFe@C/Nafion composite was verified by field-emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). Electrochemical impedance spectroscopy (EIS) was used to evaluate its electrical properties as a modified material for an electrochemical sensor. Compared with CoFe-MOF-74 precursor modified electrode, CoFe@C/Nafion electrode exhibited a great synergic catalytic effect and extremely increased the oxidation peak signal of NHDC. The effects of various experimental conditions on the oxidation of NHDC were investigated and the calibration plot was tested. The results bespoken that CoFe@C/Nafion GCE has good reproducibility and anti-interference under the optimal experimental conditions. In addition, the differential pulse current response of NHDC was linear with its concentration within the range 0.08 ~ 20 µmol/L, and the linear regression coefficient was 0.9957. The detection limit was as low as 14.2 nmol/L (S/N = 3). In order to further verify the feasibility of the method, it was successfully used to determine the content of NHDC in Chinese medicine, with a satisfactory result, good in accordance with that of high performance liquid chromatography (HPLC).


Asunto(s)
Chalconas , Cobalto , Técnicas Electroquímicas , Electrodos , Límite de Detección , Estructuras Metalorgánicas , Cobalto/química , Estructuras Metalorgánicas/química , Chalconas/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Medicamentos Herbarios Chinos/química , Medicamentos Herbarios Chinos/análisis , Hesperidina/análogos & derivados , Hesperidina/análisis , Hesperidina/química , Polímeros de Fluorocarbono/química , Oxidación-Reducción , Carbono/química , Reproducibilidad de los Resultados , Hierro/química
17.
ACS Chem Neurosci ; 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38958080

RESUMEN

Electrical brain stimulation has been used in vivo and in vitro to investigate neural circuitry. Historically, stimulation parameters such as amplitude, frequency, and pulse width were varied to investigate their effects on neurotransmitter release and behavior. These experiments have traditionally employed fixed-frequency stimulation patterns, but it has previously been found that neurons are more precisely tuned to variable input. Introducing variability into the interpulse interval of stimulation pulses will inform on how dopaminergic release can be modulated by variability in pulse timing. Here, dopaminergic release in rats is monitored in the nucleus accumbens (NAc), a key dopaminergic center which plays a role in learning and motivation, by fast-scan cyclic voltammetry. Dopaminergic release in the NAc could also be modulated by stimulation region due to differences in connectivity. We targeted two regions for stimulation─the medial forebrain bundle (MFB) and the medial prefrontal cortex (mPFC)─due to their involvement in reward processing and projections to the NAc. Our goal is to investigate how variable interpulse interval stimulation patterns delivered to these regions affect the time course of dopamine release in the NAc. We found that stimulating the MFB with these variable stimulation patterns saw a highly responsive, frequency-driven dopaminergic response. In contrast, variable stimulation patterns applied to the mPFC were not as sensitive to the variable frequency changes. This work will help inform on how stimulation patterns can be tuned specifically to the stimulation region to improve the efficiency of electrical stimulation and control dopamine release.

18.
Future Microbiol ; : 1-14, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38904296

RESUMEN

Microbial biofilms, complex assemblies enveloped in extracellular matrices, are significant contributors to various infections. Traditional in vitro biofilm characterization methods, though informative, often disrupt the biofilm structure. The need to address biofilm-related infections urgently emphasizes the importance of continuous monitoring and timely interventions. This review provides a focused examination of advancements in real-time biofilm detection techniques, specifically in electrochemical, optical and mechanical systems. The potential applications of real-time detection in managing and monitoring biofilm growth in industrial settings, preventing medical infections, comprehending biofilm dynamics and evaluating control strategies highlight the necessity for it. Crucially, the review emphasizes the importance of evaluating these methods for their accuracy and reliability in real-time biofilm detection, offering valuable insights for precise interventions across various applications.


[Box: see text].

19.
Nanomaterials (Basel) ; 14(11)2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38869542

RESUMEN

Fentanyl (FTN) and synthetic analogs of FTN continue to ravage populations across the globe, including in the United States where opioids are increasingly being used and abused and are causing a staggering and growing number of overdose deaths each year. This growing pandemic is worsened by the ease with which FTN can be derivatized into numerous derivatives. Understanding the chemical properties/behaviors of the FTN class of compounds is critical for developing effective chemical detection schemes using nanoparticles (NPs) to optimize important chemical interactions. Halogen bonding (XB) is an intermolecular interaction between a polarized halogen atom on a molecule and e--rich sites on another molecule, the latter of which is present at two or more sites on most fentanyl-type structures. Density functional theory (DFT) is used to identify these XB acceptor sites on different FTN derivatives. The high toxicity of these compounds necessitated a "fragmentation" strategy where smaller, non-toxic molecules resembling parts of the opioids acted as mimics of XB acceptor sites present on intact FTN and its derivatives. DFT of the fragments' interactions informed solution measurements of XB using 19F NMR titrations as well as electrochemical measurements of XB at self-assembled monolayer (SAM)-modified electrodes featuring XB donor ligands. Gold NPs, known as monolayer-protected clusters (MPCs), were also functionalized with strong XB donor ligands and assembled into films, and their interactions with FTN "fragments" were studied using voltammetry. Ultimately, spectroscopy and TEM analysis were combined to study whole-molecule FTN interactions with the functionalized MPCs in solution. The results suggested that the strongest XB interaction site on FTN, while common to most of the drug's derivatives, is not strong enough to induce NP-aggregation detection but may be better exploited in sensing schemes involving films.

20.
Electrochim Acta ; 4942024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38881690

RESUMEN

Laser-induced graphene (LIG) electrodes have become popular for electrochemical sensor fabrication due to their simplicity for batch production without the use of reagents. The high surface area and favorable electrocatalytic properties also enable the design of small electrochemical devices while retaining the desired electrochemical performance. In this work, we systematically investigated the effect of LIG working electrode size, from 0.8 mm to 4.0 mm diameter, on their electrochemical properties, since it has been widely assumed that the electrochemistry of LIG electrodes is independent of size above the microelectrode size regime. The background and faradaic current from cyclic voltammetry (CV) of an outer-sphere redox probe [Ru(NH3)6]3+ showed that smaller LIG electrodes had a higher electrode roughness factor and electroactive surface ratio than those of the larger electrodes. Moreover, CV of the surface-sensitive redox probes [Fe(CN)6]3- and dopamine revealed that smaller electrodes exhibited better electrocatalytic properties, with enhanced electron transfer kinetics. Scanning electron microscopy, Raman spectroscopy, and X-ray photoelectron spectroscopy showed that the physical and chemical surface structure were different at the electrode center versus the edges, so the electrochemical properties of the smaller electrodes were improved by having rougher surface and more density of the graphitic edge planes, and more oxide-containing groups, leading to better electrochemistry. The difference could be explained by the different photothermal reaction time from the laser scribing process that causes different stable carbon morphology to form on the polymer surface. Our results give a new insight on relationships between surface structure and electrochemistry of LIG electrodes and are useful for designing miniaturized electrochemical devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...