Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36.801
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39011510

RESUMEN

Objectives: Blister pack (BP) ingestion poses serious risks, such as gastrointestinal perforation, and accurate localization by computed tomography (CT) is a common practice. However, while it has been reported in vitro that CT visibility varies with the material type of BPs, there have been no reports on this variability in clinical settings. In this study, we investigated the CT detection rates of different BPs in clinical settings. Methods: This single-center retrospective study from 2010 to 2022 included patients who underwent endoscopic foreign body removal for BP ingestion. The patients were categorized into two groups for BP components, the polypropylene (PP) and the polyvinyl chloride (PVC)/polyvinylidene chloride (PVDC) groups. The primary outcome was the comparison of CT detection rates between the groups. We also evaluated whether the BPs contained tablets and analyzed their locations. Results: This study included 61 patients (15 in the PP group and 46 in the PVC/PVDC group). Detection rates were 97.8% for the PVC/PVDC group compared to 53.3% for the PP group, a significant difference (p < 0.01). No cases of BPs composed solely of PP were detected by CT. Blister packs were most commonly found in the upper thoracic esophagus. Conclusions: Even in a clinical setting, the detection rates of PVC and PVDC were higher than that of PP alone. Identifying PP without tablets has proven challenging in clinical. Considering the risk of perforation, these findings suggest that esophagogastroduodenoscopy may be necessary, even if CT detection is negative.

2.
Biomaterials ; 313: 122814, 2025 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39243672

RESUMEN

Radiotherapy as a mainstay of in-depth cervical cancer (CC) treatment suffers from its radioresistance. Radiodynamic therapy (RDT) effectively reverses radio-resistance by generating reactive oxygen species (ROS) with deep tissue penetration. However, the photosensitizers stimulated by X-ray have high toxicity and energy attenuation. Therefore, X-ray responsive diselenide-bridged mesoporous silica nanoparticles (DMSNs) are designed, loading X-ray-activated photosensitizer acridine orange (AO) for spot blasting RDT like Trojan-horse against radio-resistance cervical cancer (R-CC). DMSNs can encapsulate a large amount of AO, in the tumor microenvironment (TME), which has a high concentration of hydrogen peroxide, X-ray radiation triggers the cleavage of diselenide bonds, leading to the degradation of DMSNs and the consequent release of AO directly at the tumor site. On the one hand, it solves the problems of rapid drug clearance, adverse distribution, and side effects caused by simple AO treatment. On the other hand, it fully utilizes the advantages of highly penetrating X-ray responsive RDT to enhance radiotherapy sensitivity. This approach results in ROS-induced mitochondria damage, inhibition of DNA damage repair, cell cycle arrest and promotion of cancer cell apoptosis in R-CC. The X-ray responsive DMSNs@AO hold considerable potential in overcoming obstacles for advanced RDT in the treatment of R-CC.


Asunto(s)
Nanopartículas , Dióxido de Silicio , Humanos , Animales , Rayos X , Nanopartículas/química , Femenino , Dióxido de Silicio/química , Ratones , Neoplasias del Cuello Uterino/terapia , Neoplasias del Cuello Uterino/tratamiento farmacológico , Neoplasias del Cuello Uterino/patología , Especies Reactivas de Oxígeno/metabolismo , Fármacos Fotosensibilizantes/farmacología , Fármacos Fotosensibilizantes/uso terapéutico , Tolerancia a Radiación/efectos de los fármacos , Microambiente Tumoral/efectos de los fármacos , Ratones Desnudos , Células HeLa , Ratones Endogámicos BALB C , Apoptosis/efectos de los fármacos , Línea Celular Tumoral
3.
Arch Acad Emerg Med ; 13(1): e3, 2025.
Artículo en Inglés | MEDLINE | ID: mdl-39318866

RESUMEN

Introduction: Foreign body aspiration (FBA) is a common, life-threatening pediatric emergency and was shown to be associated with high risk of morbidity and mortality. This systematic review and meta-analysis aimed to investigate the diagnostic value of chest computed tomography (CT) scan for identification of FBA in children. Methods: From inception to May 2024, a systematic search was carried out across multiple databases including Medline, Scopus, and Web of Science, considering published papers in English language. Quality assessment of the included studies was performed using seven domains of Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Results: The systematic literature search yielded 7203 articles. The pooled sensitivity and specificity of chest CT scan for identification of FBA were 0.99 (95% CI: 0.98-0.99) and 0.97 (95% CI: 0.96-0.98), respectively. The pooled positive likelihood ratio was 10.12 (95% CI: 4.59-22.20), and pooled negative likelihood ratio was 0.05 (95% CI: 0.02-0.1). Furthermore, the area under the summarized receiver operating characteristic (SROC) curve was 0.98. Conclusion: Our meta-analysis revealed that despite high heterogeneity, in the diagnostic characteristics of chest CT scan among studies, it has high diagnostic value in identifying FBA in suspected pediatric cases.

4.
J Colloid Interface Sci ; 677(Pt A): 781-789, 2025 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39121662

RESUMEN

HYPOTHESIS: Multi-walled tubular aggregates formed by hierarchical self-assembly of beta-cyclodextrin (ß-CD) and sodium dodecylsulfate (SDS) hold a great potential as microcarriers. However, the underlying mechanism for this self-assembly is not well understood. To advance the application of these structures, it is essential to fine-tune the cavity size and comprehensively elucidate the energetic balance driving their formation: the bending modulus versus the microscopic line tension. EXPERIMENTS: We investigated temperature-induced changes in the hierarchical tubular aggregates using synchrotron small-angle X-ray scattering across a broad concentration range. Detailed analysis of the scattering patterns enabled us to determine the structural parameters of the microtubes and to construct a phase diagram of the system. FINDINGS: The microtubes grow from the outside in and melt from the inside out. We relate derived structural parameters to enthalpic changes driving the self-assembly process on the molecular level in terms of their bending modulus and microscopic line tension. We find that the conformation of the crystalline bilayer affects the saturation concentration, providing an example of a phenomenon we call conformational freezing point depression. Inspired by the colligative phenomenon of freezing point depression, well known from undergraduate physics, we model this system by including the membrane conformation, which can describe the energetics of this hierarchical system and give access to microscopic properties without free parameters.

5.
Sci Rep ; 14(1): 23210, 2024 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-39369128

RESUMEN

X-Ray micro-computed tomography (XCT) is used to reveal the micro-structural changes of banana pseudostem nanocellulose bioplastic due to a biodegradation process initiated in a formulated composting media that allowed the growth of aerobic microflora. The bioplastic itself was made of nanocellulose, which was isolated from banana pseudostem using the 2,2,6,6-Tetramethyl-1-piperidinyloxy (TEMPO) mediated oxidation method, and polyethylene glycol (PEG) as plasticiser. XCT provided insights into the 3D structural change of the bioplastic identifying the degradation process at two scales. The results showed that the local thickness and roughness of the bioplastic increased after degradation, while the density of the material decreased. Enlarged voids and tunnels were observed in the material after degradation. The formation of these tunnels is attributed to the popping of internal PEG-containing voids because of the generation of gases, which after forming may further accelerate biodegradation by microbial activity.


Asunto(s)
Biodegradación Ambiental , Celulosa , Musa , Musa/metabolismo , Celulosa/metabolismo , Celulosa/química , Microtomografía por Rayos X , Polietilenglicoles/química , Nanoestructuras/química , Óxidos N-Cíclicos
6.
Cureus ; 16(9): e68804, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39371791

RESUMEN

Tracheobronchial foreign body (TFB) aspiration in adults is uncommon but can be life-threatening, often due to differences in airway sizes and reflexes. Symptoms associated with TFB are typically choking episodes followed by cough and dyspnea, but sometimes it can lead to acute asphyxiation. Chest radiography and computed tomography can provide information about the foreign body, its characteristics, and its location, however, bronchoscopy remains the preferred method for diagnosis and removal. In this case report, we describe an instance of hijab pin aspiration where the patient expectorated the foreign body immediately following the administration of inhaled salbutamol.

7.
J Conserv Dent Endod ; 27(8): 817-821, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39372571

RESUMEN

Context: An acidic hydrogen potential (pH) in an inflammatory condition in the periapical tissues may affect the properties of repair bioceramic cement. Aims: The aim of this study was to evaluate the effect of pH on the volumetric change of the ready-to-use bioceramic NeoPUTTY (NP) compared to the powder/liquid MTA Repair HP (MTAHP) after immersion in butyric acid (BA, pH 4.1) or phosphate-buffered saline (PBS, pH 7.35). Subjects and Methods: Dentin tubes filled with NP or MTAHP were scanned in micro-computed tomography (micro-CT) after 24 h. Then, the specimens were immersed in 1.5 mL of BA: NP/BA, MTAHP/BA or PBS: NP/PBS, MTAHP/PBS. After 7 days, new micro-CT scans were performed. The percentage of volumetric change (extremities and internal part) of the materials was assessed. Statistical Analysis Used: ANOVA/Tukey and Kruskal-Wallis tests were performed (α =0.05). Results: All materials showed a volumetric decrease after immersion in BA or PBS at the extremities in contact with the solutions. MTAHP/BA showed the highest volumetric loss. There was no difference in the volumetric change when the internal part of the materials was evaluated. Conclusions: An acid pH negatively affects the volumetric stability of MTAHP. Low values of volumetric change were demonstrated for NP in both immersion environments.

8.
Sci Rep ; 14(1): 23311, 2024 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-39375399

RESUMEN

Cardiovascular disease (CVD) is a major chronic disease worldwide and its risk factors have long been investigating in epidemiological studies. Our study aims to develop a body composition-based risk score and integrate it into the Framingham Risk Score (FRS) to improve CVD prediction among well-functioning older adults. We included 1882 older adults from the Health, Aging and Body Composition (Health ABC) study to screen body composition variables obtained from the Dual-energy X-ray absorptiometry (DXA). Three models were developed and compared: the 4-DXA model, the refit FRS, and the refit FRS plus 4-DXA model. C-statistics were 0.62 (95% CI: 0.59, 0.65) for the refit FRS, 0.58 (95% CI: 0.55, 0.61) for the 4-DXA model, and 0.63 (95% CI: 0.60, 0.66) for the refit FRS plus 4-DXA model. Compared to the refit FRS, the refit FRS plus 4-DXA model slightly improved CVD outcome prediction as the discrimination slope, net reclassification index, and the integrated discrimination index were 0.053 (95% CI: 0.041, 0.066), 0.098 (95% CI = - 0.0033, 0.20) and 0.013 (95% CI: 0.0069-0.019). This study provides a model for more accurate risk stratification and draws more attention on DXA-based indices in the clinical setting. It also encourages further research in validating the developed risk score in more diverse population and in investigating a broader range of CVD risk factors.


Asunto(s)
Absorciometría de Fotón , Composición Corporal , Enfermedades Cardiovasculares , Humanos , Anciano , Masculino , Femenino , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/diagnóstico por imagen , Medición de Riesgo/métodos , Factores de Riesgo , Persona de Mediana Edad , Envejecimiento , Anciano de 80 o más Años
9.
Sci Rep ; 14(1): 23275, 2024 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-39375406

RESUMEN

Craniofacial structure and dental hard tissue used to be researched on by traditional imaging tools such as light microscope, electron microscope and micro-CT. Due to the limitations of imaging principle, resolution and 3D rendering reconstruction technique, traditional imaging tools are constrained for presenting fine structure and precise measurements. Here a brand-new imaging equipment-3D X-ray microscope is introduced to realize a more efficient scanning by demonstrating the comparison of the craniofacial structures and dental hard tissue of diabetes and normal DBA mouse. To explore a higher resolution, more efficient imaging measurement and 3D reconstruction method on craniofacial structure and dental hard tissue. The study included 12 DBA mice which were divided into two groups (control group and diabetes group). The heads were separated and scanned by 3D X-ray microscope, after which regions of interest were selected, followed by measurement and 3D reconstruction based on microscope attached software Dragonfly pro©. Hemi-mandibles were collected for enamel mineral density assessment supported by QRM-MicroCT-HA phantom. Data was submitted to paired t-tests at a 95% confidence level. The automatic assessed enamel thickness of diabetes mice decreased on average, whereas the rest of manual measurements and automatic assessed density showed no statistical difference. We constructed HA phantom assisted enamel density procedure in Dragonfly software. Craniofacial structure and dental hard tissue were well-presented both in 2D slide and 3D reconstruction viewport by 3D X-ray microscope which can be routinely used as craniofacial structure and dental hard tissue imaging tool.


Asunto(s)
Imagenología Tridimensional , Cráneo , Microtomografía por Rayos X , Animales , Imagenología Tridimensional/métodos , Ratones , Microtomografía por Rayos X/métodos , Cráneo/diagnóstico por imagen , Cráneo/patología , Microscopía/métodos , Esmalte Dental/diagnóstico por imagen , Fantasmas de Imagen
10.
Sci Rep ; 14(1): 23272, 2024 10 07.
Artículo en Inglés | MEDLINE | ID: mdl-39375440

RESUMEN

According to the World Health Organization (WHO), pneumonia kills about 2 million children under the age of 5 every year. Traditional machine learning methods can be used to diagnose chest X-rays of pneumonia in children, but there is a privacy and security issue in centralizing the data for training. Federated learning prevents data privacy leakage by sharing only the model and not the data, and it has a wide range of application in the medical field. We use federated learning method for classification, which effectively protects data security. And for the data heterogeneity phenomenon existing in the actual scenario, which will seriously affect the classification effect, we propose a method based on two-end control variables. Specifically, based on the classical federated learning FedAvg algorithm, we modify the loss function on the client side by adding a regular term or a penalty term, and add momentum after the average aggregation on the server side. The federated learning approach prevents the data privacy leakage problem compared to the traditional machine learning approach. In order to solve the problem of low classification accuracy due to data heterogeneity, our proposed method based on two-end control variables achieves an average improvement of 2% and an accuracy of 98% on average, and 99% individually, compared to the previous federated learning algorithms and the latest diffusion model-based method. The classification results and methodology of this study can be utilized by clinicians worldwide to improve the overall detection of pediatric pneumonia.


Asunto(s)
Algoritmos , Aprendizaje Automático , Neumonía , Humanos , Neumonía/diagnóstico por imagen , Neumonía/diagnóstico , Preescolar , Niño , Lactante , Radiografía Torácica/métodos
11.
Data Brief ; 57: 110905, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39376484

RESUMEN

The monomeric red fluorescent protein DsRed (mDsRed) is an optical probe widely used in multicolor applications in flow cytometry and fluorescence microscopy. Although the crystal structure of monomeric DsRed has been determined, its molecular dynamics have not been fully elucidated. To better understand its molecular flexibility, the crystal structure of mDsRed was recently determined, and its structure and temperature factors were analyzed. Solvent-accessible hole connected with the mDsRed chromophore was observed on the mDsRed surface structure. Electron density map analysis showed the tyrosine-ring group of the mDsRed chromophore in a cis-conformation, exhibiting flexibility with a nonplanar configuration between the tyrosine and imidazoline rings of the chromophore. Temperature factor analysis indicated that the top and bottom of the ß-barrel are relatively flexible. These structural findings extended our understanding of the molecular flexibility of mDsRed. The detailed data collection and structure determination reported in this study can be used for future structural analyses.

12.
J Surg Case Rep ; 2024(10): rjae615, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39376721

RESUMEN

We reported a case of pericardial agenesis discovered at the age of 60 during coronary artery bypass grafting surgery. However, this anomaly was not treated during the initial surgery. During the post-operatory period, the patient developed recurrent unilateral right pulmonary edema whenever assuming a semi-upright position. We hypothesized that the positional hemodynamic alterations in this patient were related to this rare congenital anomaly. The patient underwent reoperation, 48 hours later, with synthetic pericardial reconstruction and experienced an uneventful recovery during follow-up.

13.
J Ultrasound Med ; 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39377662

RESUMEN

OBJECTIVES: Adolescent idiopathic scoliosis (AIS) is a 3-dimensional spinal deformity involving lateral curvature, sagittal plane imbalance, and vertebral rotation. In China, AIS affects over 3 million individuals, with 300,000 new cases annually. AIS impacts physical and psychological well-being, necessitating tailored treatment plans based on growth risk factors. This study evaluates the consistency of ultrasound and X-ray assessments of the Risser sign in AIS patients and explores correlations between iliac crest distance and pelvic rotation degree. METHODS: This prospective study enrolled 80 patients diagnosed with AIS from June to September 2023 at Changzhou Sports Hospital. Eligible participants were aged 10-18 with a Cobb angle >10°. Ultrasonographic examinations were conducted by 3 experienced physicians using the VINNO V10 portable ultrasound system. The primary outcome was the Risser stage determined by X-ray and ultrasound, with secondary outcomes including thoracic and thoracic-lumbar segment rotation angles. Statistical analyses included kappa statistics, correlation analyses, and multiple regression. RESULTS: Among the 77 valid cases, 154 iliac wings were evaluated, with a high concordance rate of 77% between ultrasound and X-ray assessments. kappa values for left and right iliac crests were 0.723 and 0.808, respectively. Grouping Risser grades (0-1, 2-3, and 4-5) into 3 categories yielded kappa values of 0.93, 0.96, and 0.93, indicating high consistency. Significant correlations were found between iliac crest distances and rotation angles (left iliac crest distance and left thoracic rotation angle, r = 0.56, P < .001; right iliac crest distance and right thoracic-lumbar rotation angle, r = 0.69, P < .001; right iliac crest distance and right thoracic rotation angle, r = 0.39, P < .01). CONCLUSIONS: Ultrasound is a reliable, radiation-free alternative to X-ray for assessing the Risser sign in AIS patients. Despite observed inconsistencies in intermediate Risser grades, ultrasound's ability to reduce radiation exposure and provide consistent results makes it a valuable tool in clinical practice. Further research is needed to optimize ultrasound techniques and explore its potential for early detection and intervention in scoliosis management.

14.
Angew Chem Int Ed Engl ; : e202417234, 2024 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-39378024

RESUMEN

Molecules based on polyatomic bismuth substructures are currently attracting a lot of attention owing to this heavy and essentially non-toxic element's uncommon chemical and physical properties, which include unprecedented bonding properties. Hexaatomic {Bi6} substructures that underly more complex cluster structures were recently reported to adopt different structures or exhibit different structural details as a consequence of the charge of the {Bi6} unit. This leads to either crown-shaped cycles for a nominal Bi66- or differently distorted trigonal prisms for compositions close to Bi62-. It was predicted by quantum chemistry that Bi64- should adopt a distinctly distorted boat-like shape, yet a corresponding compound has remained elusive. Here, we report a proof of this assumption by the synthesis and isolation of [K(crypt-222)]2[Bi6{Zn(hmds)}2]∙1.5THF (1), comprising a bimetallic [Bi6{Zn(hmds)}2]2- cluster that fulfils the prediction for the geometric and electronic structure of the missing link (crypt-222 = 4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo-[8.8.8]hexa-cosane, hmds = hexamethyldisilazanid). A detailed quantum chemical study shows how the nature of Lewis-acidic transition metal complexes - in particular, 12-electron fragments - control and fine-tune the resulting {Bi6} architectures in accordance with the degree of electron-withdrawal from the polybismuthide core.

15.
J Biol Chem ; : 107853, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39362470

RESUMEN

YcjN is a putative substrate binding protein expressed from a cluster of genes involved in carbohydrate import and metabolism in Escherichia coli. Here, we determine the crystal structure of YcjN to a resolution of 1.95 Å, revealing that its three-dimensional structure is similar to substrate binding proteins in subcluster D-I, which includes the well-characterized maltose binding protein (MBP). Furthermore, we found that recombinant overexpression of YcjN results in the formation of a lipidated form of YcjN that is posttranslationally diacylated at cysteine 21. Comparisons of size-exclusion chromatography profiles and dynamic light scattering measurements of lipidated and non-lipidated YcjN proteins suggest that lipidated YcjN aggregates in solution via its lipid moiety. Additionally, bioinformatic analysis indicates that YcjN-like proteins may exist in both Bacteria and Archaea, potentially in both lipidated and non-lipidated forms. Together, our results provide a better understanding of the aggregation properties of recombinantly expressed bacterial lipoproteins in solution and establish a foundation for future studies that aim to elucidate the role of these proteins in bacterial physiology.

16.
Neurospine ; 21(3): 966-972, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39363491

RESUMEN

OBJECTIVE: To investigate the ability of radiological parameter canal bone ratio (CBR) to assess bone mineral density and to differentiate between patients with primary and multiple osteoporotic vertebral compression fracture (OVCF). METHODS: A retrospective analysis was conducted on OVCF patients treated at our hospital. CBR was measured through full-spine x-rays. Patients were categorized into primary and multiple fracture groups. Receiver operating characteristic curve analysis and area under the curve (AUC) calculation were used to assess the ability of parameters to predict osteoporosis and multiple fractures. Predictors of T values were analyzed by multiple linear regression, and independent risk factors for multiple fractures were determined by multiple logistic regression analysis. RESULTS: CBR showed a moderate negative correlation with dual-energy x-ray absorptiometry T values (r = -0.642, p < 0.01). Higher CBR (odds ratio [OR], -6.483; 95% confidence interval [CI], -8.234 to -4.732; p < 0.01) and lower body mass index (OR, 0.054; 95% CI, 0.023-0.086; p < 0.01) were independent risk factors for osteoporosis. Patients with multiple fractures had lower T values (mean ± standard deviation [SD]: -3.76 ± 0.73 vs. -2.83 ± 0.75, p < 0.01) and higher CBR (mean ± SD: 0.54 ± 0.07 vs. 0.46 ± 0.06, p < 0.01). CBR had an AUC of 0.819 in predicting multiple fractures with a threshold of 0.53. T values prediction had an AUC of 0.816 with a threshold of -3.45. CBR > 0.53 was an independent risk factor for multiple fractures (OR, 14.66; 95% CI, 4.97-43.22; p < 0.01). CONCLUSION: CBR is negatively correlated with bone mineral density (BMD) and can be a novel opportunistic BMD assessment method. It is a simple and effective measurement index for predicting multiple fractures, with predictive performance not inferior to T values.

17.
Artículo en Inglés | MEDLINE | ID: mdl-39354099

RESUMEN

BACKGROUND: Increased Posterior Tibial Slope (PTS) angle has been reported to be a risk factor for primary anterior cruciate ligament (ACL) tears. However, it is unknown whether increased PTS has an associated increased risk for non-contact versus contact ACL injury. PURPOSE: The purpose of this study is to determine whether patients with non-contact ACL injury have a higher PTS angle than those with contact ACL injury. METHODS: A total of 1700 patients who underwent primary ACL reconstruction between January 2011 and June 2023 at a single academic institution were initially included. Electronic medical records were reviewed for demographic information as well as evidence that the patient sustained a contact or non-contact ACL injury. Patients in the contact cohort were propensity score matched to patients in the non-contact cohort by age, sex and BMI. Additionally, patients in the contact cohort were then propensity score matched to a control group of patients with intact ACLs also by age, sex and BMI. RESULTS: One hundred and two patients with contact injury were initially identified and 1598 patients with non-contact injuries were identified. Of the 102, 67 had knee X-rays that were suitable for measurement. These 67 contact injury patients were propensity score matched to 67 noncontact patient and 67 patients with intact ACLs based on age, sex and BMI. There were no significant differences between contact and non-contact cohorts in age (28.7±6.3 vs. 27.1±6.5, p = 0.147), sex (Female: 36.0% vs. 34.3%, p = 0.858), or BMI (26.7±5.6 vs 26.1±3.4, p = 0.475). There was no significant difference in PTS angle between contact versus non-contact ACL injury patients (11.6±3.0 vs.11.6±2.8, p = 0.894). There was a significant difference in PTS between the contact ACL injury and the intact cohort (11.6±3.0 vs. 10.0±3.9, p = 0.010) and the non-contact ACL injury and the intact cohort (11.6±2.8 vs. 10.0±3.9, p = 0.010). CONCLUSION: There was no significant difference in the degree of PTS between patients who sustained contact versus non-contact ACL injuries. Additionally, there was a significantly increased PTS in both the contact and non-contact ACL injury cohorts compared to patients with intact ACLs.

18.
Neth Heart J ; 2024 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-39356451

RESUMEN

Photon-counting detector computed tomography (PCD-CT) has emerged as a revolutionary technology in CT imaging. PCD-CT offers significant advancements over conventional energy-integrating detector CT, including increased spatial resolution, artefact reduction and inherent spectral imaging capabilities. In cardiac imaging, PCD-CT can offer a more accurate assessment of coronary artery disease, plaque characterisation and the in-stent lumen. Additionally, it might improve the visualisation of myocardial fibrosis through qualitative late enhancement imaging and quantitative extracellular volume measurements. The use of PCD-CT in cardiac imaging holds significant potential, positioning itself as a valuable modality that could serve as a one-stop-shop by integrating both angiography and tissue characterisation into a single examination. Despite its potential, large-scale clinical trials, standardisation of protocols and cost-effectiveness considerations are required for its broader integration into clinical practice. This narrative review provides an overview of the current literature on PCD-CT regarding the possibilities and limitations of cardiac imaging.

19.
Environ Sci Technol ; 2024 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-39361056

RESUMEN

This study exposes U(VI)-sorbed schwertmannite and jarosite to biotic reductive incubations under field-relevant conditions and examines the changes in aqueous and solid-phase speciation of U, Fe, and S as well as associated microbial communities over 180 days. The chemical, X-ray absorption spectroscopy, X-ray diffraction, and microscopic data demonstrated that the U(VI)-sorbed schwertmannite underwent a rapid reductive dissolution and solid-phase transformation to goethite, during which the surface-sorbed U(VI) was partly reduced and mostly repartitioned to monomeric U(VI)/U(IV) complexes by carboxyl and phosphoryl ligands on biomass or organic substances. Furthermore, the microbial data suggest that these processes were likely driven by the consecutive developments of fermentative and sulfate- and iron- reducing microbial communities. In contrast, the U(VI)-sorbed jarosite only stimulated the growth of some fermentative communities and underwent very limited reductive dissolution and thus, remaining in its initial state with no detectable mineralogical transformation and solid-phase U reduction/repartitioning. Accordingly, these two biotic incubations did not induce increased risk of U reliberation to the aqueous phase. These findings have important implications for understanding the interactions of schwertmannite/jarosite with microbial communities and colinked behavior and fate of U following the establishment of reducing conditions in various acidic and U-rich settings.

20.
Front Artif Intell ; 7: 1410841, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39359646

RESUMEN

This paper investigates uncertainty quantification (UQ) techniques in multi-class classification of chest X-ray images (COVID-19, Pneumonia, and Normal). We evaluate Bayesian Neural Networks (BNN) and the Deep Neural Network with UQ (DNN with UQ) techniques, including Monte Carlo dropout, Ensemble Bayesian Neural Network (EBNN), Ensemble Monte Carlo (EMC) dropout, across different evaluation metrics. Our analysis reveals that DNN with UQ, especially EBNN and EMC dropout, consistently outperform BNNs. For example, in Class 0 vs. All, EBNN achieved a UAcc of 92.6%, UAUC-ROC of 95.0%, and a Brier Score of 0.157, significantly surpassing BNN's performance. Similarly, EMC Dropout excelled in Class 1 vs. All with a UAcc of 83.5%, UAUC-ROC of 95.8%, and a Brier Score of 0.165. These advanced models demonstrated higher accuracy, better discriaminative capability, and more accurate probabilistic predictions. Our findings highlight the efficacy of DNN with UQ in enhancing model reliability and interpretability, making them highly suitable for critical healthcare applications like chest X-ray imageQ6 classification.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA