Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 605
Filtrar
1.
Int J Surg Case Rep ; 123: 110292, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39303488

RESUMEN

INTRODUCTION: Aortic dissection, a serious medical condition characterized by a tear in the aorta's inner layer leading to the establishment of a false channel within the vessel wall, in this report, we present a very rare case of asymptomatic substantial aortic dissection spanning from the ascending aorta to the abdominal aorta. CASE PRESENTATION: A 36-year-old male with fever and cough was found to have clinical features suggestive of Marfan syndrome. Examination revealed bilateral fine crackles and a diastolic heart murmur. Imaging showed bilateral infiltrates, hyperinflation, and aortic dissection. Echocardiography confirmed severe aortic valve regurgitation and Stanford type A dissection. Despite recommended surgery, the patient opted for medical therapy due to financial constraints, showing stable cardiac anomalies after 6 months. DISCUSSION: Aortic dissection, a critical cardiovascular emergency, affects mainly the elderly, exacerbated by hypertension, atherosclerosis, and connective tissue disorders. Early detection via CT and biomarkers is crucial. Type A dissections typically require surgical repair, while endovascular repair is used for complex Type B cases, reducing long-term mortality. The TEM system aids in categorization, guiding treatment. Conditions like Marfan syndrome significantly contribute to aortic wall degeneration, requiring close monitoring and intervention. CONCLUSION: The coalescence of aortic dissections with Marfan syndrome underscores the need for tailored monitoring in high-risk populations and highlights the silent complexities of cardiovascular pathologies, urging refined diagnostics and therapeutic approaches.

2.
J Bone Metab ; 31(3): 236-245, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39307524

RESUMEN

BACKGROUND: Abdominal aortic calcification (AAC) on lateral lumbar radiographs increases the risk of cardiovascular events and mortality. However, data on the association between AAC detected in dual energy X-ray absorptiometry (DXA) and the risk of mortality in the general population are scarce. METHODS: The present study was based on data from participants aged ≥40 years in the National Health and Nutrition Examination Survey (NHANES) cycle of 2013 to 2014. Vertebral assessment of lateral spine DXA scans was used to provide AAC measurements at vertebrae L1-L4. The extent of AAC was defined according to the Kauppila AAC-24 scores (0-1, 2-5, ≥6), and the NHANES 2019 public-use linked mortality files were used to assess mortality status. RESULTS: Of the 2,962 participants who were included in this study, with a mean age of 57.4 years and a median follow-up of 69.9 months, 252 (8.5%) died. Of the deaths, 84 (33.3%) occurred due to cardiovascular disease. The Cox proportional hazards models revealed that participants with AAC-24 scores ≥6 were 1.7 times more likely to die than those with AAC-24 scores 0-1 (Hazard ratio, 1.75; 95% confidence interval, 1.13-2.71). Moreover, older adults and women with AAC-24 scores ≥6 were 2.8 and 2.4 times more likely to die than their counterparts with AAC-24 scores 0-1, respectively. Conversely, a non-significant risk of cardiovascular mortality was found among participants with AAC-24 scores ≥6. CONCLUSIONS: The extent of AAC detected on vertebral fracture assessment DXA was associated with an increased risk of all-cause mortality in adults, particularly older adults and women.

4.
Heliyon ; 10(16): e35994, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39220907

RESUMEN

Osteophytes grow on vertebral bodies and sometimes form a sharp edge, which can induce traumatic abdominal aortic injury (TAAI). However, these cases are extremely rare, although osteophytes grow in almost everyone with age. Herein, we report a rare case of TAAI due to a sharp osteophyte dislocation following a compression fracture, with a literature review. An 83-year-old man presented with back pain after a fall and subsequently developed shock. His lactate level was elevated on arrival, although we could not identify the cause of the shock. Enhanced computed tomography (CT) revealed a compression fracture of the lumbar spine, a sharp osteophyte penetrating the abdominal aorta, and contrast media spurting to the retroperitoneum. We immediately transfused, administered continuous noradrenaline to maintain his vital signs, and consulted a vascular surgeon and radiologist to arrange for an emergency operation. However, the operating room was not immediately available. We tried to evacuate a trauma center, which took time due to the COVID-19 outbreak. Thereafter, the patient's condition deteriorated, resulting in a pulseless electrical activity, and he passed away 3 h after arrival. Afterward, the previous CT image and a sharp osteophyte were observed in the lumbar vertebrae in contact with the abdominal aorta. There were only eight reports where the aorta was injured by osteophytes. From our review, unlike the proportion of common TAAI, injuries due to strong external forces were relatively small. There was no specific symptom, and the vertebral levels of osteophytes were concentrated in Th12-L3. The most common morphology of aorta injuries is pseudoaneurysm formation. Moreover, five of the patients developed hemorrhage. Considering these previous reports, we should pay attention to the aorta in front of the vertebral bodies regardless of the mechanism of injury when a CT image of patients shows osteophytes.

5.
J Clin Ultrasound ; 2024 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-39344280

RESUMEN

This meta-analysis evaluates the efficacy of point-of-care ultrasound (POCUS) in diagnosing abdominal aortic aneurysm (AAA) in the emergency department (ED). A systematic search of PubMed, Cochrane Library, Scopus, and Google Scholar identified studies published until July 2024. Nine studies were included, revealing that POCUS is highly accurate in diagnosing AAA, with a pooled sensitivity of 98.33% and specificity of 99.84%. Additionally, data from three studies indicated that 24.5% of patients with positive AAA scans were diagnosed with ruptured AAAs. The results suggest that emergency physicians can accurately detect and manage AAA using POCUS, even with limited training.

7.
J Clin Med ; 13(15)2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39124566

RESUMEN

Ruptured abdominal aortic aneurysms (rAAAs) are life-threatening and require emergent surgical therapy. Endovascular aortic repair for rupture (rEVAR) has become the leading strategy due to its minimal invasive approach with expected lower morbidity and mortality, especially in patients presenting with hemodynamic instability and relevant comorbidities. Following rEVAR, intraoperative angiography or early postinterventional computed tomography angiography have to exclude early type 1 or 3 endoleaks requiring immediate reintervention. Persistent type 2 endoleaks (T2ELs) after rEVAR, in contrast to elective cases, can cause possibly lethal situations due to continuing extravascular blood loss through the remaining aortic aneurysm rupture site. Therefore, early identification of relevant persistent T2ELs associated with continuous bleeding and hemodynamic instability and immediate management is mandatory in the acute postoperative setting following rEVAR. Different techniques and concepts for the occlusion of T2ELs after rEVAR are available, and most of them are also used for relevant T2ELs after elective EVAR. In addition to various interventional embolization procedures for persistent T2ELs, some patients require open surgical occlusion of T2EL-feeding arteries, abdominal compartment decompression or direct surgical patch occlusion of the aneurysm rupture site after rEVAR. So far, in the acute situation of rAAAs, indications for preemptive or intraoperative T2EL embolization during rEVAR have not been established. In the long term, persistent T2ELs after rEVAR can lead to continuous aneurysm expansion with the possible development of secondary proximal type I endoleaks and an increased risk of re-rupture requiring regular follow-up and early consideration for reintervention. To date, only very few studies have investigated T2ELs after rEVAR or compared outcomes with those from elective EVAR regarding the special aspects of persisting T2ELs. This narrative review is intended to present the current knowledge on the incidence, natural history, relevance and strategies for T2EL management after rEVAR.

8.
Abdom Radiol (NY) ; 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39212684

RESUMEN

PURPOSE: Luminal linear findings (LLF) of the abdominal aorta are often called aortic "flaps," triggering concern for acute aortic syndrome. However, these "flaps" are unlikely to represent intimomedial dissection given isolation to the abdominal aorta, short length, and incidental discovery. We aim to characterize the etiology and stability of LLF. METHODS: CT reports finalized January 2021-December 2022 were queried for terms "focal dissection," "dissection flap," "linear filling defect," and "linear flap." Patients were excluded for thoracoabdominal dissection, LLF in non-aortic vessel, no prior contrast-enhanced imaging, and less than 6 months between exams. Index exam reviewed for presence of LLF, atherosclerosis, and aortic caliber at LLF site. Prior exam assessed for aortic caliber and aortic findings at subsequent LLF site. Patients with unchanged LLF between exams were categorized "Stable" and patients with interval change "Dynamic." RESULTS: Seven hundred and two cases identified. After exclusions, imaging from 70 patients reviewed; 1 excluded for no LLF. Stable Cohort of 39 patients had median follow-up 31 months (range 6-284 months). 87% of aortas were moderately/severely atherosclerotic (n = 16 moderate, n = 18 severe), while 69% were ectatic/aneurysmal (n = 27). Dynamic Cohort of 20 patients had median follow-up of 70 months (range 14-244 months). All were atherosclerotic and 80% were ectatic/aneurysmal compared to 25% ectatic/aneurysmal at prior imaging. Mural thrombus was present at the site of the future LLF in 17 of 20, thrombosed PAU in 1, and no focal findings in 2. CONCLUSION: Short-segment LLFs within the abdominal aorta arise from prior mural thrombus and demonstrate long term stability. Clinically and radiographically indolent, LLFs should not be called dissection flaps.

9.
Heliyon ; 10(15): e35605, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39170537

RESUMEN

Atypical aortic coarctation is an exceedingly rare condition, and there are very few reported cases of anesthetic management for bypass surgery in patients with severe impaired cardiac function. We present the anesthetic management of a 68-year-old woman with atypical aortic coarctation due to Takayasu arteritis and severely impaired cardiac function, who underwent ascending-to-abdominal aorta bypass surgery under extracorporeal membrane oxygenation (ECMO). The patient's severe cardiac dysfunction was due to sustained afterload from the coarctation, leading to recurrent episodes of heart failure. Surgical intervention was deemed necessary, and a decision was made to perform a bypass operation. The patient experienced a transient state of shock following induction of anesthesia, but subsequent perioperative care was safely managed with the implementation of ECMO. For bypass surgery performed on patients with severe cardiac dysfunction due to atypical coarctation of the aorta, it is crucial to prepare for potential circulatory collapse during anesthesia induction and the surgical procedure. This preparation includes meticulous planning of the anesthesia induction method and ensuring that ECMO can be established promptly if needed.

11.
Rev Cardiovasc Med ; 25(5): 150, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-39076501

RESUMEN

Background: Thoracic aortic aneurysms are often an accidental finding and result from a degenerative process. Medical therapy includes pharmacological control of arterial hypertension and smoking cessation, that slows the growth of aneurysms. An association between the dilatation of the ascending and abdominal aorta has been already reported. The aim of the study was to identify possible demographic and clinical factors that may implicate further imaging diagnostics in patients with ascending aorta dilatation. Methods: There were 181 (93 (53%) males and 88 (47%) females) patients with a median age of 54 (41-62) years who underwent cardiac magnetic resonance due to non-vascular diseases, were enrolled into retrospective analysis. Results: Multivariable analysis revealed ascending aorta dilatation (odds ratios (OR) = 7.45, 95% confidence interval (CI): 1.98-28.0, p = 0.003) and co-existence of coronary artery disease (OR = 8.68, 95% CI: 2.15-35.1, p = 0.002) as significant predictors for thoracic descending aorta dilatation. In patients with abdominal aorta dilatation, the multivariable analysis showed a predictive value of ascending aortic dilatation (OR = 14.8, 95% CI: 2.36-92.8, p = 0.004) and age (OR = 1.04, 95% CI: 1.00-1.08, p = 0.027). In addition, cut-off values were established for age groups determining the risk of thoracic aorta dilatation over 49 years and abdominal aorta dilatation over 54 years. Conclusions: The results of our analysis showed predictive factors, including ascending aorta dilatation and co-existence of coronary artery disease, particularly over 49 years of age for thoracic, while ascending aorta dilatation and age, particularly over 54 years, for abdominal aorta dilatation. These features may be considered to increase clinical vigilance in patients with aortic diameter abnormalities.

12.
Front Immunol ; 15: 1411979, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38989288

RESUMEN

Background: Kawasaki disease (KD), an acute febrile illness and systemic vasculitis, is the leading cause of acquired heart disease in children in industrialized countries. KD leads to the development of coronary artery aneurysms (CAA) in affected children, which may persist for months and even years after the acute phase of the disease. There is an unmet need to characterize the immune and pathological mechanisms of the long-term complications of KD. Methods: We examined cardiovascular complications in the Lactobacillus casei cell wall extract (LCWE) mouse model of KD-like vasculitis over 4 months. The long-term immune, pathological, and functional changes occurring in cardiovascular lesions were characterized by histological examination, flow cytometric analysis, immunofluorescent staining of cardiovascular tissues, and transthoracic echocardiogram. Results: CAA and abdominal aorta dilations were detected up to 16 weeks following LCWE injection and initiation of acute vasculitis. We observed alterations in the composition of circulating immune cell profiles, such as increased monocyte frequencies in the acute phase of the disease and higher counts of neutrophils. We determined a positive correlation between circulating neutrophil and inflammatory monocyte counts and the severity of cardiovascular lesions early after LCWE injection. LCWE-induced KD-like vasculitis was associated with myocarditis and myocardial dysfunction, characterized by diminished ejection fraction and left ventricular remodeling, which worsened over time. We observed extensive fibrosis within the inflamed cardiac tissue early in the disease and myocardial fibrosis in later stages. Conclusion: Our findings indicate that increased circulating neutrophil counts in the acute phase are a reliable predictor of cardiovascular inflammation severity in LCWE-injected mice. Furthermore, long-term cardiac complications stemming from inflammatory cell infiltrations in the aortic root and coronary arteries, myocardial dysfunction, and myocardial fibrosis persist over long periods and are still detected up to 16 weeks after LCWE injection.


Asunto(s)
Pared Celular , Modelos Animales de Enfermedad , Fibrosis , Lacticaseibacillus casei , Síndrome Mucocutáneo Linfonodular , Vasculitis , Animales , Ratones , Pared Celular/inmunología , Vasculitis/inmunología , Vasculitis/etiología , Vasculitis/patología , Síndrome Mucocutáneo Linfonodular/inmunología , Síndrome Mucocutáneo Linfonodular/complicaciones , Masculino , Miocarditis/etiología , Miocarditis/patología , Miocarditis/inmunología , Inflamación/inmunología
13.
Eur Radiol ; 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39026062

RESUMEN

BACKGROUND: Increased diameters of the aorta are associated with increased mortality risk. In the present analyses, we assessed whether aortic diameters are associated with cardiovascular and all-cause mortality in community-dwelling individuals free of known cardiovascular disease (CVD). METHODS: MRI-derived vascular parameters of the thoracic and abdominal aorta from 2668 participants (median age = 53 years; 51.1% women) of the population-based SHIP-START-2 and SHIP-TREND-0 cohorts without CVD were analyzed. Age- and sex-adjusted, as well as multivariable-adjusted Cox-proportional hazard models, were used to estimate associations of diameters of six different aortic segments to mortality. RESULTS: Over a median follow-up time of 10.6 years (IQR: 8.7; 12.4), a total of 188 participants (126 men and 62 women) died, of which 38 deaths were due to CVD. In unadjusted models, mortality rates were higher in participants with aortic diameters above the median compared to below the median for all investigated aortic sections (all log-rank p < 0.001). In multivariable-adjusted models, the diameters of the ascending thoracic aorta (HR = 1.34 95% CI: 1.04; 1.72, p = 0.022) and of the infrarenal aorta (HR = 3.75 95% CI: 1.06; 13.3, p = 0.040), modeled continuously, were associated with greater cardiovascular mortality. The diameter of the subphrenic aorta was associated with higher cardiovascular mortality only in the age and sex-adjusted model (HR = 3.65 95% CI: 1.01; 13.3, p = 0.049). None of the investigated aortic segments were associated with all-cause mortality. CONCLUSION: Non-indexed diameters of the ascending thoracic and infrarenal aorta were associated with higher cardiovascular mortality but not with all-cause mortality in a population sample free of clinically overt CVD at baseline. CLINICAL RELEVANCE STATEMENT: Increased aortic diameter is associated with cardiovascular mortality and can help to identify high-risk patients. KEY POINTS: Increased aortic diameter is associated with mortality. Non-indexed diameters of the ascending and infrarenal aorta are associated with cardiovascular mortality but not all-cause mortality. Aortic diameter measurements support the estimate of cardiovascular mortality.

14.
Acta Med Indones ; 56(2): 206-209, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-39010778

RESUMEN

Pseudoaneurysms are false aneurysms that mostly occur at the site of arterial injury. Pseudoaneurysm is the most frequent complication after catheter-associated interventions and occurs because of an insufficient closure of the puncture site. However, there are several reported cases of patients with pseudoaneurysm without a prior history of vascular intervention. We described a case of ruptured giant abdominal aortic pseudoaneurysm in a patient with no prior history of vascular intervention, with an initial complaint of abdominal pain. The patient successfully received EVAR therapy using a kissing graft.


Asunto(s)
Aneurisma Falso , Aneurisma de la Aorta Abdominal , Humanos , Aneurisma Falso/etiología , Aneurisma Falso/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Masculino , Rotura de la Aorta/cirugía , Rotura de la Aorta/etiología , Rotura de la Aorta/diagnóstico por imagen , Dolor Abdominal/etiología , Rotura Espontánea , Procedimientos Endovasculares , Aorta Abdominal/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Implantación de Prótesis Vascular , Persona de Mediana Edad
15.
Cureus ; 16(6): e63135, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39055463

RESUMEN

Βlunt trauma is a common injury in children; however, blunt abdominal aortic trauma is extremely rare and is accompanied by high rates of morbidity and mortality. We report our initial experience with the endovascular management of an abdominal aortic rupture in a 12-year-old boy after he was involved in a motor vehicle accident. The patient was a backseat-restrained passenger. Upon admission, he had a Glasgow Coma Scale of 15, was hemodynamically stable, and complained of abdominal pain. The computed tomography revealed a rupture in the abdominal aorta along with a distally extending pseudoaneurysm, free fluid in the peritoneal cavity, and a large retroperitoneal hematoma. The rest associated injuries were a Grade III splenic injury, a retroclival epidural hematoma in the first cervical vertebra level, a right clavicle fracture, a bilateral minor pneumothorax, along with bilateral pulmonary lacerations and contusions in the thoracic vertebrae. Given the extent of the intraabdominal injuries and the risk for open laparotomy, the decision to proceed with endovascular stenting instead of open surgical repair was made. The patient tolerated the procedure well and an angiography confirmed the result. The postoperative period was uneventful and the associated injuries were treated conservatively without complications. Although blunt abdominal aortic trauma is extremely rare in children, endovascular management seems to be a new and feasible therapeutic approach.

16.
BMC Infect Dis ; 24(1): 669, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38965458

RESUMEN

BACKGROUND: Abdominal aorta-duodenal fistulas are rare abnormal communications between the abdominal aorta and duodenum. Secondary abdominal aorta-duodenal fistulas often result from endovascular surgery for aneurysms and can present as severe late complications. CASE PRESENTATION: A 50-year-old male patient underwent endovascular reconstruction for an infrarenal abdominal aortic pseudoaneurysm. Prior to the operation, he was diagnosed with Acquired Immune Deficiency Syndrome and Syphilis. Two years later, he was readmitted with lower extremity pain and fever. Blood cultures grew Enterococcus faecium, Salmonella, and Streptococcus anginosus. Sepsis was successfully treated with comprehensive anti-infective therapy. He was readmitted 6 months later, with blood cultures growing Enterococcus faecium and Escherichia coli. Although computed tomography did not show contrast agent leakage, we suspected an abdominal aorta-duodenal fistula. Esophagogastroduodenoscopy confirmed this suspicion. The patient underwent in situ abdominal aortic repair and received long-term antibiotic therapy. He remained symptom-free during a year and a half of follow-up. CONCLUSIONS: This case suggests that recurrent infections with non-typhoidal Salmonella and gut bacteria may be an initial clue to secondary abdominal aorta-duodenal fistula.


Asunto(s)
Sepsis , Humanos , Masculino , Persona de Mediana Edad , Sepsis/microbiología , Sepsis/complicaciones , Aorta Abdominal/cirugía , Aorta Abdominal/microbiología , Enterococcus faecium/aislamiento & purificación , Antibacterianos/uso terapéutico , Streptococcus anginosus/aislamiento & purificación , Fístula Intestinal/microbiología , Fístula Intestinal/cirugía , Fístula Intestinal/complicaciones , Salmonella/aislamiento & purificación , Escherichia coli/aislamiento & purificación , Recurrencia , Enfermedades Duodenales/microbiología , Enfermedades Duodenales/cirugía , Enfermedades Duodenales/complicaciones , Infecciones por Salmonella/microbiología , Infecciones por Salmonella/complicaciones , Infecciones por Salmonella/diagnóstico , Infecciones por Salmonella/tratamiento farmacológico
17.
Rev. colomb. cir ; 39(4): 585-594, Julio 5, 2024. fig
Artículo en Español | LILACS | ID: biblio-1566017

RESUMEN

Introducción. Las complicaciones posteriores a la reparación endovascular de aneurisma (EVAR) pueden resolverse con técnicas endovasculares. Sin embargo, cuando está indicada, la explantación de una endoprótesis es un procedimiento complejo, que se asocia a lesiones vasculares o viscerales, con alta morbimortalidad, en pacientes con edad avanzada y múltiples comorbilidades, y por lo tanto, alto riesgo quirúrgico. No existen dispositivos producidos por la industria para explantar las endoprótesis aórticas, por lo que el objetivo de este trabajo fue desarrollar un dispositivo para la explantación de endoprótesis aórticas. Métodos. Se llevó a cabo un estudio experimental, en fase preclínica, para desarrollar un dispositivo para la explantación de endoprótesis aórticas, con pruebas en modelos 3D y en un modelo animal porcino cadavérico. Resultados. Es factible desarrollar un modelo experimental de un nuevo dispositivo para explantar endoprótesis aórticas, denominado explantador de Cabrera, y comprobar su funcionamiento en un modelo animal cadavérico. El uso del explantador de Cabrera limitó el daño de la pared aórtica por parte de la endoprótesis en un 100 % al momento de su explantación en un modelo experimental ex vivo. Conclusión. Usando una jeringa septo, el explantador de Cabrera es superior a la técnica estándar de explantación de una endoprótesis al limitar la lesión de la pared aórtica, al colapsar y liberar los ganchos de fijación suprarrenal de forma controlada y segura al interior de la luz aórtica y, posteriormente, extraerla de forma rápida y efectiva, conservando la mayor cantidad de aorta sana para la posterior reconstrucción aorto-ilíaca.


Introduction. Complications after endovascular aneurysm repair (EVAR) can be resolved with endovascular techniques; however, when indicated, stent explantation is a complex procedure, which is associated with vascular or visceral injuries, with high morbidity and mortality in patients, with advanced age and multiple comorbidities, and therefore high surgical risk. There are no devices produced by the industry to explant aortic endoprostheses, so the objective of this work was to develop a device for the explantation of aortic endoprostheses. Methods. An experimental study was carried out, in the preclinical phase, to develop a device for the explantation of aortic endoprostheses, with tests in 3D models and in a cadaveric porcine animal model. Results. It is feasible to develop an experimental model of a new device for explanting aortic endoprostheses, called Cabrera explanter, and verify its operation in a cadaveric animal model. The use of the Cabrera explanter limited damage to the aortic wall by the endoprosthesis by 100% at the time of explantation in an ex vivo experimental model. Conclusions. Using a septum syringe, the Cabrera explanter is superior to the standard stent explantation technique by limiting injury to the aortic wall, collapsing and releasing the adrenal fixation hooks in a controlled and safe manner into the aortic lumen, and subsequently, extract it quickly and effectively, preserving the greatest amount of healthy aorta for the subsequent aorto-iliac reconstruction.


Asunto(s)
Humanos , Remoción de Dispositivos , Procedimientos Endovasculares , Reparación Endovascular de Aneurismas , Aorta Abdominal , Prótesis e Implantes , Aneurisma de la Aorta Abdominal
18.
Int J Gynaecol Obstet ; 167(1): 109-127, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38899567

RESUMEN

BACKGROUND: Placenta accreta spectrum (PAS) disorder is a critical and severe obstetric condition associated with high risk of intraoperative massive hemorrhage and cesarean hysterectomy. Severe obstetric hemorrhage is currently one of the leading causes of maternal death worldwide. Prophylactic balloon occlusions, including prophylactic balloon occlusion of the abdominal aorta (PBOAA) and prophylactic balloon occlusion of the internal iliac arteries (PBOIIA), are the most common means of controlling hemorrhage in patients with PAS disorder, but their effectiveness is still debated. OBJECTIVE: A systematic review and meta-analysis were conducted to evaluate the clinical effectiveness of prophylactic balloon occlusion during cesarean section (CS) in improving maternal outcomes for PAS patients. SEARCH STRATEGY: MEDLINE, EMBASE, OVID, PubMed and the Cochrane Library were systematically searched from the inception dates to June 2022, using the keywords "placenta accreta spectrum disorder/morbidly adherent placenta (placenta previa, placenta accreta, placenta increta, placenta percreta), balloon occlusion, internal iliac arteries, abdominal aorta, hemorrhage, hysterectomy, estimated blood loss (EBL), packed red blood cells (PRBCs)" to identify the systematic reviews or meta-analyses. SELECTION CRITERIA: All articles regarding PAS disorders and including the application of balloon occlusion were included in the screening. DATA COLLECTION AND ANALYSIS: Two independent researchers performed the data extraction and assessed study quality. EBL volume and PRBC transfusion volume was regarded as the primary endpoints. Random and fixed effects models were used for the meta-analysis (RRs and 95% CIs), and the Newcastle-Ottawa Scale was used for quality assessments. MAIN RESULTS: Of 429 studies identified, a total of 35 trials involving the application of balloon occlusion for patients with PAS disorder during CS were included. A total of 19 studies involving 935 patients who underwent PBOIIA were included in the PBOIIA group, and 851 patients were included in control 1 group. Ten studies including 428 patients with PAS who underwent PBOAA were allocated to the PBOAA group, and 324 patients without PBOAA were included in control 2 group. Simultaneously, we compared the effect on PBOAA and PBOIIA including seven studies, which referred to 267 cases in the PBOAA group and 313 cases in the PBOIIA group. The results showed that the PBOIIA group had a reduced EBL volume (MD: 342.06 mL, 95% CI: -509.90 to -174.23 mL, I2 = 77%, P < 0.0001) and PRBC volume (MD: -1.57 U, 95% CI: -2.49 to -0.66 U, I2 = 91%, P = 0.0008) than that in control 1 group. With regard to the EBL volume (MD: -926.42 mL, 95% CI: -1437.07 to -415.77 mL, I2 = 96%, P = 0.0004) and PRBC transfusion volume (MD: -2.42 U, 95% CI: -4.25 to -0.59 U, I2 = 99%, P = 0.009) we found significant differences between the PBOAA group and control 2 group. Prophylactic balloon occlusion (PBOAA and PBOIIA) had a significant effect on reducing intraoperative blood loss and blood transfusion volume in patients with PAS. Moreover, PBOAA was more effective than PBOIIA in reducing intraoperative blood loss (MD: -406.63 mL, 95% CI: -754.12 to -59.13 mL, I2 = 92%, P = 0.020), but no significant difference in controlling PRBCs (MD: -3.48 U, 95% CI: -8.90 to 1.95 U, I2 = 99%, P = 0.210) between the PBOIIA group and the PBOAA group. Hierarchical analysis was conducted by differentiating gestational weeks and maternal age to reduce the high heterogeneity of meta-analysis. Hierarchical analysis results demonstrated the heterogeneities of the study were reduced to some extent, and gestational weeks and maternal age might be the cause of increased heterogeneity. CONCLUSION: Prophylactic balloon occlusion is a safe and effective method to control hemorrhage and reduce PRBC transfusion volume for patients with PAS, and PBOAA could reduce more intraoperative blood loss than PBOIIA. However, we found no statistical difference in lessening packed red blood cell transfusion volume for PAS patients. Hence, preoperative prophylactic balloon occlusion is the recommended application for PAS patients in obstetric CSs. Furthermore, PBOAA is preferred for controlling intraoperative bleeding in patients with corresponding medical conditions.


Asunto(s)
Oclusión con Balón , Cesárea , Placenta Accreta , Hemorragia Posparto , Humanos , Femenino , Placenta Accreta/terapia , Placenta Accreta/cirugía , Embarazo , Oclusión con Balón/métodos , Cesárea/efectos adversos , Hemorragia Posparto/prevención & control , Hemorragia Posparto/etiología , Arteria Ilíaca , Pérdida de Sangre Quirúrgica/prevención & control , Histerectomía
19.
Vascular ; : 17085381241257742, 2024 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-38861481

RESUMEN

OBJECTIVES: Abdominal Aortic Aneurysms (AAA) in females are less prevalent, have higher expansion rates and experience rupture at smaller diameters than in males. Studies have compared outcomes of the retroperitoneal (RP) and transperitoneal (TP) approach in open aortic aneurysm repair (OAR) with conflicting results. No study to date has compared the two approaches solely in females. In this study we compare midterm outcomes of the RP and TP approach in females undergoing OAR. METHODS: Single-center, retrospective review of all females undergoing OAR from 2010 to 2021. Patients undergoing elective, symptomatic and ruptured OAR were included. The cohort was stratified by surgical approach RP versus TP and midterm outcomes were compared amongst the groups. Outcomes included mortality, graft related, and non-graft related complications. RESULTS: A total of 244 patients (RP n = 133; TP n = 111) were identified. Follow-up period was 28 ± 30.7 months. Baseline perioperative characteristics were similar except that more people in the RP group had ejection fraction ((EF) > 50% (82% vs 68%), p = .037). Patients who underwent RP repair had longer visceral/renal ischemia time (p = .01), larger graft diameter (18 vs 16 mm; p = <0.001), were more likely to have a suprarenal clamp placed(70.5 vs 48.2; p < .001), and had decreased autotransfusion volume (611 vs 861 mL; p < .01) compared to those who underwent TP repair. Number of deaths was higher in the TP group during study follow-up period (36.4 vs 23.8; p = .035), but the difference of the time to event analysis was not significant. There was no difference in all-cause survival at 36 months between RP and TP (77.8 vs 76.8; p = .045). Overall midterm complications were 9.5% in both groups. Any graft related complication was 1.8% in TP versus 3% RP (p = .69). In a multivariable model, after adjusting for age, urgency, smoking, prior aneurysm repair, and ASA level, the hazard ratio decreases with the RP approach, however this did not reach significance (p = .052). CONCLUSION: In a 12-year period of OAR in females, TP and RP results were comparable at midterm analysis. The RP approach appeared to be used more often for OAR requiring suprarenal clamping. Although the TP group had increased mortality, the difference of the time to event analysis was not significant. Midterm postoperative complications in both groups were low. This suggests that both approaches are safe in the female population and decision should be driven by anatomy and surgeon's preference.

20.
Heliyon ; 10(11): e32186, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38867988

RESUMEN

Anatomical cardiovascular etiologies are less frequently investigated and identified in cases of orthostatic intolerance, which can have a profound impact on a patient's functional status. Here, we present a 26-year-old female with a recent diagnosis of hyperadrenergic postural orthostatic tachycardia and hypertension who was found to have diminished pedal pulses. Workup revealed an underlying midaortic syndrome that was then surgically corrected with resolution of symptoms. We discuss the epidemiology, presentation, and management of this rare condition, as well as its role in our patient's symptomatology.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA