1.
Eur Arch Otorhinolaryngol ; 281(1): 43-49, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37466660

RESUMEN

PURPOSE: In cochlear implantation with flexible lateral wall electrode arrays, a cochlear coverage (CC) range between 70% and 80% is considered ideal for optimal speech perception. To achieve this CC, the cochlear implant (CI) electrode array has to be chosen according to the individual cochlear duct length (CDL). Here, we mathematically analyzed the suitability of different flexible lateral wall electrode array lengths covering between 70% and 80% of the CDL. METHODS: In a retrospective cross-sectional study preoperative high-resolution computed tomography (HRCT) from patients undergoing cochlear implantation was investigated. The CDL was estimated using an otosurgical planning software and the CI electrode array lengths covering 70-80% of the CDL was calculated using (i) linear and (ii) non-linear models. RESULTS: The analysis of 120 HRCT data sets showed significantly different model-dependent CDL. Significant differences between the CC of 70% assessed from linear and non-linear models (mean difference: 2.5 mm, p < 0.001) and the CC of 80% assessed from linear and non-linear models (mean difference: 1.5 mm, p < 0.001) were found. In up to 25% of the patients none of the existing flexible lateral wall electrode arrays fit into this range. In 59 cases (49,2%) the models did not agree on the suitable electrode arrays. CONCLUSIONS: The CC varies depending on the underlying CDL approximation, which critically influences electrode array choice. Based on the literature, we hypothesize that the non-linear method systematically overestimates the CC and may lead to rather too short electrode array choices. Future studies need to assess the accuracy of the individual mathematical models.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Estudios Retrospectivos , Estudios Transversales , Dinámicas no Lineales , Cóclea/diagnóstico por imagen , Cóclea/cirugía
2.
Acta Otolaryngol ; 143(9): 748-752, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37737708

RESUMEN

BACKGROUND: To achieve better speech performance following cochlear implantation (CI), measuring the patient's cochlear duct length (CDL) and determining the appropriate length of the CI array are important. OBJECTIVE: To investigate the CDL in CI patients after using the OTOPLAN software preoperatively and compare the results of angular insertion depth (AID) estimation by OTOPLAN and postoperative radiography. MATERIALS AND METHODS: The study included 105 Japanese CI patients with normal cochleae. We measured the CDL using OTOPLAN and the position of the tip channel of the electrode for each selected electrode array, and estimated the AID using the software. RESULTS: The mean CDL was 35.1 ± 1.6 mm. Preoperatively, the mean estimated AID was 580.3 ± 57.8°. Postoperative radiography revealed a mean AID of 583.0 ± 56.7°, demonstrating a strong linear correlation between the two measurements (R2 = 0.635). CONCLUSION AND SIGNIFICANCE: Our findings revealed that CDL varies widely, which is consistent with previous studies. To achieve better speech perception, surgeons should select the appropriate length of CI electrode array based on the individual's CDL. Preoperative measurement of each CDL by OTOPLAN, which is clinically feasible and comparable to postoperative evaluation, can be used to ensure selection of the appropriate electrode array length.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Implantación Coclear/métodos , Cóclea/cirugía , Conducto Coclear , Tomografía Computarizada por Rayos X/métodos
3.
Cochlear Implants Int ; 24(5): 273-281, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37489512

RESUMEN

OBJECTIVE: To investigate whether revision surgery with the same device results in a change in three key indicators of electrode positioning: scalar location, mean modiolar distance (M¯), and angular insertion depth (AID). METHODS: Retrospective analysis of a cochlear implant database at a university-based tertiary medical center. Intra-operative CT scans were obtained after initial and revision implantation. Electrode array (EA) position was calculated using auto-segmentation techniques. Initial and revision scalar location, M¯, and AID were compared. RESULTS: Mean change in M¯ for all ears was -0.07 mm (SD 0.24 mm; P = 0.16). The mean change in AID for all ears was -5° (SD 67°; P = 0.72). Three initial implantations with pre-curved EAs resulted in a translocation from Scala Tympani (ST) to Scala Vestibuli (SV). Two remained translocated after revision, while one was corrected when revised with a straight EA. An additional five translocations occurred after revision. CONCLUSIONS: In this study examining revision cochlear implantation from a single manufacturer, we demonstrated no significant change in key indicators of EA positioning, even when revising with a different style of electrode. However, the revision EA is not necessarily confined by the initial trajectory and there may be an increased risk of translocation.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Estudios Retrospectivos , Cóclea , Reimplantación
4.
J Pers Med ; 13(4)2023 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-37109019

RESUMEN

BACKGROUND: Radiological high-resolution computed tomography-based evaluation of cochlear implant candidates' cochlear duct length (CDL) has become the method of choice for electrode array selection. The aim of the present study was to evaluate if MRI-based data match CT-based data and if this impacts on electrode array choice. METHODS: Participants were 39 children. CDL, length at two turns, diameters, and height of the cochlea were determined via CT and MRI by three raters using tablet-based otosurgical planning software. Personalized electrode array length, angular insertion depth (AID), intra- and interrater differences, and reliability were calculated. RESULTS: Mean intrarater difference of CT- versus MRI-based CDL was 0.528 ± 0.483 mm without significant differences. Individual length at two turns differed between 28.0 mm and 36.6 mm. Intrarater reliability between CT versus MRI measurements was high (intra-class correlation coefficient (ICC): 0.929-0.938). Selection of the optimal electrode array based on CT and MRI matched in 90.1% of cases. Mean AID was 629.5° based on the CT and 634.6° based on the MRI; this is not a significant difference. ICC of the mean interrater reliability was 0.887 for the CT-based evaluation and 0.82 for the MRI-based evaluation. CONCLUSION: MRI-based CDL measurement shows a low intrarater difference and a high interrater reliability and is therefore suitable for personalized electrode array selection.

5.
Eur Arch Otorhinolaryngol ; 280(6): 2707-2714, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36436080

RESUMEN

PURPOSE: The aims of this study were to compare speech recognition at different postoperative times for both ears in bilaterally implanted patients and to assess the influence of the time of deafness, frequency-to-place mismatch, angular insertion depth (AID) and angular separation between neighbouring electrode contacts on audiometric outcomes. METHODS: This study was performed at an academic tertiary referral centre. A total of 19 adult patients (6 men, 13 women), who received sequential bilateral implantation with lateral wall electrode arrays, were analysed in retrospective. Statistical analysis was performed using two-sided t test, Wilcoxon test, median test, and Spearman's correlation. RESULTS: Postlingually deafened patients (deafness after the age of 10) had a significantly better speech perception (WRS65[CI]) than the perilingually deafened subjects (deafness at the age of 1-10 years) (p < 0.001). Comparison of cochlear duct length between peri- and postlingually deafened subjects showed a slightly significantly smaller cochleae in perilingual patients (p = 0.045). No association between frequency-to-place mismatch as well as angular separation and speech perception could be detected. There was even no significant difference between the both ears in the intraindividual comparison, even if insertion parameters differed. CONCLUSION: The exact electrode position seems to have less influence on the speech comprehension of CI patients than already established parameters as preoperative speech recognition or duration of deafness.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Sordera , Percepción del Habla , Adulto , Masculino , Humanos , Femenino , Lactante , Preescolar , Niño , Sordera/cirugía , Estudios Retrospectivos , Electrodos Implantados
6.
Otol Neurotol Open ; 3(4): e045, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38516541

RESUMEN

Objective: The suitable electrode array choice is broadly discussed in cochlear implantation surgery. Whether to use a shorter electrode length under the aim of structure preservation versus choosing a longer array to achieve a greater cochlear coverage is a matter of debate. The aim of this review is to identify the impact of the insertion depth of a cochlear implant (CI) electrode array on CI users' speech perception outcomes. Databases Reviewed: PubMed was searched for English-language articles that were published in a peer-reviewed journal from 1997 to 2022. Methods: A systematic electronic search of the literature was carried out using PubMed to find relevant literature on the impact of insertion depth on speech perception. The review was conducted according to the preferred reporting items for systematic reviews and meta-analyses guidelines of reporting. Studies in both, children and adults with pre- or postlingual hearing loss, implanted with a CI were included in this study. Articles written in languages other than English, literature reviews, meta-analyses, animal studies, histopathological studies, or studies pertaining exclusively to imaging modalities without reporting correlations between insertion depth and speech outcomes were excluded. The risk of bias was determined using the "Risk of Bias in Nonrandomized Studies of Interventions" tool. Articles were extracted by 2 authors independently using predefined search terms. The titles and abstracts were screened manually to identify studies that potentially meet the inclusion criteria. The extracted information included: the study population, type of hearing loss, outcomes reported, devices used, speech perception outcomes, insertion depth (linear insertion depth and/or the angular insertion depth), and correlation between insertion depth and the speech perception outcomes. Results: A total of 215 relevant studies were assessed for eligibility. Twenty-three studies met the inclusion criteria and were analyzed further. Seven studies found no significant correlation between insertion depth and speech perception outcomes. Fifteen found either a significant positive correlation or a positive effect between insertion depth and speech perception. Only 1 study found a significant negative correlation between insertion depth and speech perception outcomes. Conclusion: Although most studies reported a positive effect of insertion depth on speech perception outcomes, one-third of the identified studies reported no correlation. Thus, the insertion depth must be considered as a contributing factor to speech perception rather than as a major decisive criterion. Registration: This review has been registered in PROSPERO, the international prospective register of systematic reviews (CRD42021257547), available at https://www.crd.york.ac.uk/PROSPERO/.

7.
Clin Neuroradiol ; 32(1): 175-183, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34142163

RESUMEN

PURPOSE: To assess the role of flat panel computed tomography (FPCT) in the evaluation of cochlear implant (CI) electrode position and its relation to speech perception. METHODS: From March 2015 to March 2019, we retrospectively enrolled deaf subjects ≥ 18 years who underwent unilateral CI by one surgeon, imaged with FPCT and assessed with disyllabic words score before CI and at 6 months of follow-up. We calculated the disyllabic score difference before CI and after CI (ΔSDS) and divided the subjects in favorable and unfavorable outcome groups using the median ΔSDS as a cutoff. We compared the demographic, clinical, electrode characteristics, and the CI positioning variables scalar position, surgical insertion depth (SID), linear insertion depth (LID), angular insertion depth (AID) and wrapping factor (WF). RESULTS: We studied 50 subjects (F/M = 27/23; median age = 60.5 years, IQR: 50-70 years). The median ΔSDS was 80% (interquartile range [IQR]: 60-100%) in quiet and 80% (IQR: 47.5-100%) in noise. Of the subjects 23 demonstrated a favorable outcome and had earlier age at CI (median 52 years; IQR 45-67 years versus median 62 years; IQR: 56-71 years p = 0.032) and a significantly higher SID (median: 4.02 mm IQR: 3.00-5.35 mm versus median: 2.94 mm IQR: 2.06-3.90 mm; p = 0.029). No difference was found for LID (p = 0.977), AID (p = 0.302), and WF (p = 0.224). A logistic regression model built with the age at CI, number of CI electrodes, and the SID was significant χ2 ((df = 3, N = 50) = 14.517, p = 0.002). The model explained 33.7% (Nagelkerke R2) of ΔSDS variance and correctly classified 76% of the cases. CONCLUSION: The SID measured by FPCT predicts the ΔSDS at 6 months follow-up, alongside with age at implantation and number of CI electrodes.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Cóclea/cirugía , Implantación Coclear/métodos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
8.
Otolaryngol Head Neck Surg ; 165(4): 571-577, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33588627

RESUMEN

OBJECTIVE: High rates of partial insertion have been reported for cochlear implant (CI) recipients of long lateral wall electrode arrays, presumably caused by resistance encountered during insertion due to cochlear morphology. With recent advances in long-electrode array design, we sought to investigate (1) the incidence of complete insertions among patients implanted with 31.5-mm flexible arrays and (2) whether complete insertion is limited by cochlear duct length (CDL). STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. METHODS: Fifty-one adult CI recipients implanted with 31.5-mm flexible lateral wall arrays underwent postoperative computed tomography to determine the rate of complete insertion, defined as all contacts being intracochlear. CDL and angular insertion depth (AID) were compared between complete and partial insertion cohorts. RESULTS: Most cases had a complete insertion (96.1%, n = 49). Among the complete insertion cohort, the median CDL was 33.6 mm (range, 30.3-37.9 mm), and median AID was 641° (range, 533-751°). Two cases of partial insertion had relatively short CDL (31.8 mm and 32.3 mm) and shallow AID (542° and 575°). Relatively shallow AID for the 2 cases of partial insertion fails to support the idea that CDL alone prevents a complete insertion. CONCLUSION: Complete insertion of a 31.5-mm flexible array is feasible in most cases and does not appear to be limited by the range of CDL observed in this cohort. Future studies are needed to estimate other variations in cochlear morphology that could predict resistance and failure to achieve complete insertion with long arrays.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Electrodos Implantados , Adulto , Anciano , Anciano de 80 o más Años , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , North Carolina , Estudios Retrospectivos , Hueso Temporal/diagnóstico por imagen , Tomografía Computarizada por Rayos X
9.
J Med Imaging (Bellingham) ; 7(3): 031504, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32509912

RESUMEN

Purpose: Cochlear implants (CIs) use an array of electrodes surgically threaded into the cochlea to restore hearing sensation. Techniques for predicting the insertion depth of the array into the cochlea could guide surgeons toward more optimal placement of the array to reduce trauma and preserve the residual hearing. In addition to the electrode array geometry, the base insertion depth (BID) and the cochlear size could impact the overall array insertion depth. Approach: We investigated using these measurements to develop a linear regression model that can make preoperative or intraoperative predictions of the insertion depth of lateral wall CI electrodes. Computed tomography (CT) images of 86 CI recipients were analyzed. Using previously developed automated algorithms, the relative electrode position inside the cochlea was measured from the CT images. Results: A linear regression model is proposed for insertion depth prediction based on cochlea size, array geometry, and BID. The model is able to accurately predict angular insertion depths with a standard deviation of 41 deg and absolute deviation error of 32 deg. Conclusions: Surgeons may use this model for patient-customized selection of electrode array and/or to plan a BID for a given array that minimizes the likelihood of causing trauma to regions of the cochlea where residual hearing exists.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA