Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 560
Filtrar
1.
Neural Netw ; 179: 106497, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38986186

RESUMEN

The non-stationarity of EEG signals results in variability across sessions, impeding model building and data sharing. In this paper, we propose a domain adaptation method called GPL, which simultaneously considers global knowledge and prototype-based local class information to enhance the classification accuracy of motor imagery signals. Depending on the amount of labeled data available in the target domain, the method is implemented in both unsupervised and semi-supervised versions. Specifically, at the global level, we employ the maximum mean difference (MMD) loss to globally constrain the feature space, achieving comprehensive alignment. In the context of class-level operations, we propose two memory banks designed to accommodate class prototypes in each domain and constrain feature embeddings by applying two prototype-based contrastive losses. The source contrastive loss is used to organize source features spatially based on categories, thereby reconciling inter-class and intra-class relationships, while the interactive contrastive loss is employed to facilitate cross-domain information interaction. Simultaneously, in unsupervised scenarios, to mitigate the adverse effects of excessive pseudo-labels, we introduce an entropy-aware strategy that dynamically evaluates the confidence level of target data and personalized constraints on the participation of interactive contrastive loss. To validate our approach, extensive experiments were conducted on a highly regarded public EEG dataset, namely Dataset IIa of the BCI Competition IV, as well as a large-scale EEG dataset called GigaDB. The experiments yielded average classification accuracies of 86.03% and 84.22% respectively. These results demonstrate that our method is an effective EEG decoding model, conducive to advancing the development of motor imagery brain-computer interfaces. The architecture proposed in this study and the code for data partitioning can be found at https://github.com/zhangdx21/GPL.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38946233

RESUMEN

Motor imagery (MI) stands as a powerful paradigm within Brain-Computer Interface (BCI) research due to its ability to induce changes in brain rhythms detectable through common spatial patterns (CSP). However, the raw feature sets captured often contain redundant and invalid information, potentially hindering CSP performance. Methodology-wise, we propose the Information Fusion for Optimizing Temporal-Frequency Combination Pattern (IFTFCP) algorithm to enhance raw feature optimization. Initially, preprocessed data undergoes simultaneous processing in both time and frequency domains via sliding overlapping time windows and filter banks. Subsequently, we introduce the Pearson-Fisher combinational method along with Discriminant Correlation Analysis (DCA) for joint feature selection and fusion. These steps aim to refine raw electroencephalogram (EEG) features. For precise classification of binary MI problems, an Radial Basis Function (RBF)-kernel Support Vector Machine classifier is trained. To validate the efficacy of IFTFCP and evaluate it against other techniques, we conducted experimental investigations using two EEG datasets. Results indicate a notably superior classification performance, boasting an average accuracy of 78.14% and 85.98% on dataset 1 and dataset 2, which is better than other methods outlined in this article. The study's findings suggest potential benefits for the advancement of MI-based BCI strategies, particularly in the domain of feature fusion.

3.
BMC Bioinformatics ; 25(1): 227, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38956454

RESUMEN

BACKGROUND: Multivariate synchronization index (MSI) has been successfully applied for frequency detection in steady state visual evoked potential (SSVEP) based brain-computer interface (BCI) systems. However, the standard MSI algorithm and its variants cannot simultaneously take full advantage of the time-local structure and the harmonic components in SSVEP signals, which are both crucial for frequency detection performance. To overcome the limitation, we propose a novel filter bank temporally local MSI (FBTMSI) algorithm to further improve SSVEP frequency detection accuracy. The method explicitly utilizes the temporal information of signal for covariance matrix estimation and employs filter bank decomposition to exploits SSVEP-related harmonic components. RESULTS: We employed the cross-validation strategy on the public Benchmark dataset to optimize the parameters and evaluate the performance of the FBTMSI algorithm. Experimental results show that FBTMSI outperforms the standard MSI, temporally local MSI (TMSI) and filter bank driven MSI (FBMSI) algorithms across multiple experimental settings. In the case of data length of one second, the average accuracy of FBTMSI is 9.85% and 3.15% higher than that of the FBMSI and the TMSI, respectively. CONCLUSIONS: The promising results demonstrate the effectiveness of the FBTMSI algorithm for frequency recognition and show its potential in SSVEP-based BCI applications.


Asunto(s)
Algoritmos , Interfaces Cerebro-Computador , Electroencefalografía , Potenciales Evocados Visuales , Humanos , Potenciales Evocados Visuales/fisiología , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador
4.
Front Hum Neurosci ; 18: 1371631, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38957693

RESUMEN

Brain-computer interfaces (BCIs) are scientifically well established, but they rarely arrive in the daily lives of potential end-users. This could be in part because electroencephalography (EEG), a prevalent method to acquire brain activity for BCI operation, is considered too impractical to be applied in daily life of end-users with physical impairment as an assistive device. Hence, miniaturized EEG systems such as the cEEGrid have been developed. While they promise to be a step toward bridging the gap between BCI development, lab demonstrations, and home use, they still require further validation. Encouragingly, the cEEGrid has already demonstrated its ability to record visually and auditorily evoked event-related potentials (ERP), which are important as input signal for many BCIs. With this study, we aimed at evaluating the cEEGrid in the context of a BCI based on tactually evoked ERPs. To compare the cEEGrid with a conventional scalp EEG, we recorded brain activity with both systems simultaneously. Forty healthy participants were recruited to perform a P300 oddball task based on vibrotactile stimulation at four different positions. This tactile paradigm has been shown to be feasible for BCI repeatedly but has never been tested with the cEEGrid. We found distinct P300 deflections in the cEEGrid data, particularly at vertical bipolar channels. With an average of 63%, the cEEGrid classification accuracy was significantly above the chance level (25%) but significantly lower than the 81% reached with the EEG cap. Likewise, the P300 amplitude was significantly lower (cEEGrid R2-R7: 1.87 µV, Cap Cz: 3.53 µV). These results indicate that a tactile BCI using the cEEGrid could potentially be operated, albeit with lower efficiency. Additionally, participants' somatosensory sensitivity was assessed, but no correlation to the accuracy of either EEG system was shown. Our research contributes to the growing amount of literature comparing the cEEGrid to conventional EEG systems and provides first evidence that the tactile P300 can be recorded behind the ear. A BCI based on a thus simplified EEG system might be more readily accepted by potential end-users, provided the accuracy can be substantially increased, e.g., by training and improved classification.

5.
Bioengineering (Basel) ; 11(6)2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38927850

RESUMEN

The application of wearable electroencephalogram (EEG) devices is growing in brain-computer interfaces (BCI) owing to their good wearability and portability. Compared with conventional devices, wearable devices typically support fewer EEG channels. Devices with few-channel EEGs have been proven to be available for steady-state visual evoked potential (SSVEP)-based BCI. However, fewer-channel EEGs can cause the BCI performance to decrease. To address this issue, an attention-based complex spectrum-convolutional neural network (atten-CCNN) is proposed in this study, which combines a CNN with a squeeze-and-excitation block and uses the spectrum of the EEG signal as the input. The proposed model was assessed on a wearable 40-class dataset and a public 12-class dataset under subject-independent and subject-dependent conditions. The results show that whether using a three-channel EEG or single-channel EEG for SSVEP identification, atten-CCNN outperformed the baseline models, indicating that the new model can effectively enhance the performance of SSVEP-BCI with few-channel EEGs. Therefore, this SSVEP identification algorithm based on a few-channel EEG is particularly suitable for use with wearable EEG devices.

6.
Neural Netw ; 178: 106471, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38945115

RESUMEN

Brain-computer interfaces (BCIs), representing a transformative form of human-computer interaction, empower users to interact directly with external environments through brain signals. In response to the demands for high accuracy, robustness, and end-to-end capabilities within BCIs based on motor imagery (MI), this paper introduces STaRNet, a novel model that integrates multi-scale spatio-temporal convolutional neural networks (CNNs) with Riemannian geometry. Initially, STaRNet integrates a multi-scale spatio-temporal feature extraction module that captures both global and local features, facilitating the construction of Riemannian manifolds from these comprehensive spatio-temporal features. Subsequently, a matrix logarithm operation transforms the manifold-based features into the tangent space, followed by a dense layer for classification. Without preprocessing, STaRNet surpasses state-of-the-art (SOTA) models by achieving an average decoding accuracy of 83.29% and a kappa value of 0.777 on the BCI Competition IV 2a dataset, and 95.45% accuracy with a kappa value of 0.939 on the High Gamma Dataset. Additionally, a comparative analysis between STaRNet and several SOTA models, focusing on the most challenging subjects from both datasets, highlights exceptional robustness of STaRNet. Finally, the visualizations of learned frequency bands demonstrate that temporal convolutions have learned MI-related frequency bands, and the t-SNE analyses of features across multiple layers of STaRNet exhibit strong feature extraction capabilities. We believe that the accurate, robust, and end-to-end capabilities of the STaRNet will facilitate the advancement of BCIs.

7.
J Neural Eng ; 21(4)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38941986

RESUMEN

Objective.Brain-computer interfaces (BCI) have been extensively researched in controlled lab settings where the P300 event-related potential (ERP), elicited in the rapid serial visual presentation (RSVP) paradigm, has shown promising potential. However, deploying BCIs outside of laboratory settings is challenging due to the presence of contaminating artifacts that often occur as a result of activities such as talking, head movements, and body movements. These artifacts can severely contaminate the measured EEG signals and consequently impede detection of the P300 ERP. Our goal is to assess the impact of these real-world noise factors on the performance of a RSVP-BCI, specifically focusing on single-trial P300 detection.Approach.In this study, we examine the impact of movement activity on the performance of a P300-based RSVP-BCI application designed to allow users to search images at high speed. Using machine learning, we assessed P300 detection performance using both EEG data captured in optimal recording conditions (e.g. where participants were instructed to refrain from moving) and a variety of conditions where the participant intentionally produced movements to contaminate the EEG recording.Main results.The results, presented as area under the receiver operating characteristic curve (ROC-AUC) scores, provide insight into the significant impact of noise on single-trial P300 detection. Notably, there is a reduction in classifier detection accuracy when intentionally contaminated RSVP trials are used for training and testing, when compared to using non-intentionally contaminated RSVP trials.Significance.Our findings underscore the necessity of addressing and mitigating noise in EEG recordings to facilitate the use of BCIs in real-world settings, thus extending the reach of EEG technology beyond the confines of the laboratory.


Asunto(s)
Artefactos , Interfaces Cerebro-Computador , Electroencefalografía , Potenciales Relacionados con Evento P300 , Estimulación Luminosa , Humanos , Masculino , Femenino , Potenciales Relacionados con Evento P300/fisiología , Electroencefalografía/métodos , Adulto , Adulto Joven , Estimulación Luminosa/métodos , Percepción Visual/fisiología , Aprendizaje Automático , Movimiento/fisiología
8.
J Neural Eng ; 21(3)2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38885688

RESUMEN

Objective.Brain-computer interfaces (BCIs) are technologies that bypass damaged or disrupted neural pathways and directly decode brain signals to perform intended actions. BCIs for speech have the potential to restore communication by decoding the intended speech directly. Many studies have demonstrated promising results using invasive micro-electrode arrays and electrocorticography. However, the use of stereo-electroencephalography (sEEG) for speech decoding has not been fully recognized.Approach.In this research, recently released sEEG data were used to decode Dutch words spoken by epileptic participants. We decoded speech waveforms from sEEG data using advanced deep-learning methods. Three methods were implemented: a linear regression method, an recurrent neural network (RNN)-based sequence-to-sequence model (RNN), and a transformer model.Main results.Our RNN and transformer models outperformed the linear regression significantly, while no significant difference was found between the two deep-learning methods. Further investigation on individual electrodes showed that the same decoding result can be obtained using only a few of the electrodes.Significance.This study demonstrated that decoding speech from sEEG signals is possible, and the location of the electrodes is critical to the decoding performance.


Asunto(s)
Interfaces Cerebro-Computador , Aprendizaje Profundo , Electroencefalografía , Habla , Humanos , Electroencefalografía/métodos , Habla/fisiología , Masculino , Femenino , Epilepsia/fisiopatología , Epilepsia/diagnóstico , Técnicas Estereotáxicas , Adulto , Redes Neurales de la Computación
9.
Comput Methods Programs Biomed ; 254: 108294, 2024 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-38943984

RESUMEN

BACKGROUND AND OBJECTIVE: Recent advancements in brain-computer interface (BCI) technology have seen a significant shift towards incorporating complex decoding models such as deep neural networks (DNNs) to enhance performance. These models are particularly crucial for sophisticated tasks such as regression for decoding arbitrary movements. However, these BCI models trained and tested on individual data often face challenges with limited performance and generalizability across different subjects. This limitation is primarily due to a tremendous number of parameters of DNN models. Training complex models demands extensive datasets. Nevertheless, group data from many subjects may not produce sufficient decoding performance because of inherent variability in neural signals both across individuals and over time METHODS: To address these challenges, this study proposed a transfer learning approach that could effectively adapt to subject-specific variability in cortical regions. Our method involved training two separate movement decoding models: one on individual data and another on pooled group data. We then created a salience map for each cortical region from the individual model, which helped us identify the input's contribution variance across subjects. Based on the contribution variance, we combined individual and group models using a modified knowledge distillation framework. This approach allowed the group model to be universally applicable by assigning greater weights to input data, while the individual model was fine-tuned to focus on areas with significant individual variance RESULTS: Our combined model effectively encapsulated individual variability. We validated this approach with nine subjects performing arm-reaching tasks, with our method outperforming (mean correlation coefficient, r = 0.75) both individual (r = 0.70) and group models (r = 0.40) in decoding performance. In particular, there were notable improvements in cases where individual models showed low performances (e.g., r = 0.50 in the individual decoder to r = 0.61 in the proposed decoder) CONCLUSIONS: These results not only demonstrate the potential of our method for robust BCI, but also underscore its ability to generalize individual data for broader applicability.

10.
Front Hum Neurosci ; 18: 1400336, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38873652

RESUMEN

Introduction: This study aimed to evaluate the efficacy of visual P300 brain-computer interface use to support rehabilitation of chronic language production deficits commonly experienced by individuals with a left-sided stroke resulting in post-stroke aphasia. Methods: The study involved twelve participants, but five dropped out. Additionally, data points were missing for three participants in the remaining sample of seven participants. The participants underwent four assessments-a baseline, pre-assessment, post-assessment, and follow-up assessment. Between the pre-and post-assessment, the participants underwent at least 14 sessions of visual spelling using a brain-computer interface. The study aimed to investigate the impact of this intervention on attention, language production, and language comprehension and to determine whether there were any potential effects on quality of life and well-being. Results: None of the participants showed a consistent improvement in attention. All participants showed an improvement in spontaneous speech production, and three participants experienced a reduction in aphasia severity. We found an improvement in subjective quality of life and daily functioning. However, we cannot rule out the possibility of unspecific effects causing or at least contributing to these results. Conclusion: Due to challenges in assessing the patient population, resulting in a small sample size and missing data points, the results of using visual P300 brain-computer interfaces for chronic post-stroke aphasia rehabilitation are preliminary. Thus, we cannot decisively judge the potential of this approach.

11.
Sensors (Basel) ; 24(11)2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38894107

RESUMEN

Rapid serial visual presentation (RSVP) is currently a suitable gaze-independent paradigm for controlling visual brain-computer interfaces (BCIs) based on event-related potentials (ERPs), especially for users with limited eye movement control. However, unlike gaze-dependent paradigms, gaze-independent ones have received less attention concerning the specific choice of visual stimuli that are used. In gaze-dependent BCIs, images of faces-particularly those tinted red-have been shown to be effective stimuli. This study aims to evaluate whether the colour of faces used as visual stimuli influences ERP-BCI performance under RSVP. Fifteen participants tested four conditions that varied only in the visual stimulus used: grey letters (GL), red famous faces with letters (RFF), green famous faces with letters (GFF), and blue famous faces with letters (BFF). The results indicated significant accuracy differences only between the GL and GFF conditions, unlike prior gaze-dependent studies. Additionally, GL achieved higher comfort ratings compared with other face-related conditions. This study highlights that the choice of stimulus type impacts both performance and user comfort, suggesting implications for future ERP-BCI designs for users requiring gaze-independent systems.


Asunto(s)
Interfaces Cerebro-Computador , Electroencefalografía , Potenciales Evocados , Estimulación Luminosa , Humanos , Masculino , Femenino , Adulto , Electroencefalografía/métodos , Adulto Joven , Potenciales Evocados/fisiología , Movimientos Oculares/fisiología
12.
Comput Biol Med ; 178: 108727, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38897146

RESUMEN

Electroencephalograph (EEG) brain-computer interfaces (BCI) have potential to provide new paradigms for controlling computers and devices. The accuracy of brain pattern classification in EEG BCI is directly affected by the quality of features extracted from EEG signals. Currently, feature extraction heavily relies on prior knowledge to engineer features (for example from specific frequency bands); therefore, better extraction of EEG features is an important research direction. In this work, we propose an end-to-end deep neural network that automatically finds and combines features for motor imagery (MI) based EEG BCI with 4 or more imagery classes (multi-task). First, spectral domain features of EEG signals are learned by compact convolutional neural network (CCNN) layers. Then, gated recurrent unit (GRU) neural network layers automatically learn temporal patterns. Lastly, an attention mechanism dynamically combines (across EEG channels) the extracted spectral-temporal features, reducing redundancy. We test our method using BCI Competition IV-2a and a data set we collected. The average classification accuracy on 4-class BCI Competition IV-2a was 85.1 % ± 6.19 %, comparable to recent work in the field and showing low variability among participants; average classification accuracy on our 6-class data was 64.4 % ± 8.35 %. Our dynamic fusion of spectral-temporal features is end-to-end and has relatively few network parameters, and the experimental results show its effectiveness and potential.

13.
Brain Inform ; 11(1): 17, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38837089

RESUMEN

Neuromarketing is an emerging research field that aims to understand consumers' decision-making processes when choosing which product to buy. This information is highly sought after by businesses looking to improve their marketing strategies by understanding what leaves a positive or negative impression on consumers. It has the potential to revolutionize the marketing industry by enabling companies to offer engaging experiences, create more effective advertisements, avoid the wrong marketing strategies, and ultimately save millions of dollars for businesses. Therefore, good documentation is necessary to capture the current research situation in this vital sector. In this article, we present a systematic review of EEG-based Neuromarketing. We aim to shed light on the research trends, technical scopes, and potential opportunities in this field. We reviewed recent publications from valid databases and divided the popular research topics in Neuromarketing into five clusters to present the current research trend in this field. We also discuss the brain regions that are activated when making purchase decisions and their relevance to Neuromarketing applications. The article provides appropriate illustrations of marketing stimuli that can elicit authentic impressions from consumers' minds, the techniques used to process and analyze recorded brain data, and the current strategies employed to interpret the data. Finally, we offer recommendations to upcoming researchers to help them investigate the possibilities in this area more efficiently in the future.

14.
Ann Biomed Eng ; 52(8): 2269-2281, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38753110

RESUMEN

This study aims to estimate the maximum power consumption that guarantees a thermally safe operation for a titanium-enclosed chest wall unit (CWU) subcutaneously implanted in the pre-pectoral area. This unit is a central piece of an envisioned fully-implantable bi-directional brain-computer interface (BD-BCI). To this end, we created a thermal simulation model using the finite element method implemented in COMSOL. We also performed a sensitivity analysis to ensure that our predictions were robust against the natural variation of physiological and environmental parameters. Based on this analysis, we predict that the CWU can consume between 378 and 538 mW of power without raising the surrounding tissue's temperature above the thermal safety threshold of 2  ∘ C. This power budget should be sufficient to power all of the CWU's basic functionalities, which include training the decoder, online decoding, wireless data transmission, and cortical stimulation. This power budget assessment provides an important specification for the design of a CWU-an integral part of a fully-implantable BD-BCI system.


Asunto(s)
Interfaces Cerebro-Computador , Humanos , Simulación por Computador , Prótesis e Implantes , Suministros de Energía Eléctrica
15.
J Neurosci Methods ; 408: 110161, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38718901

RESUMEN

BACKGROUND: With the aid of a brain computer interface (BCI), users can communicate and receive signals wirelessly or over wired connections to operate smart devices. A BCI classifier's architecture is quite difficult since numerous elements should be combined. These elements are made up of brain signals, which also include high levels of weak sounds that could provide reliable participant recordings of daily activities. We must use computer vision techniques to create a model in order to control those information. The high dimension and volume of signals present the classification classifier with its primary obstacles. NEW METHOD: Due to this, we extracted and classified the brain activity in this study, and we also presented a novel hierarchical recursive feature elimination method that we refer to as HRFE embracing noisy additions. HRFE makes a variety of categorization suggestions to eliminate bias in classifying BCI systems of different types. We put the HRFE to the test on two BCI signal data sets-specifically, dataset I and BCI contests III-using shallow and deep convolution network classification techniques. Just a grid of assets is used to create electrocorticography (ECoG) signals on the contralateral (right) motor cortex, and these signals are recorded in the BCI contests III database. RESULTS: Using ECoG signals, we choose the top 20 features that have the biggest effects on distortion and classification selection. COMPARISON WITH EXISTING METHODS: The simulation findings show that HRFE has a significant computer vision enhancement when compared to comparable feature selection methods in the literature, particularly for ECoG signal, which achieves about 93% reliability.


Asunto(s)
Interfaces Cerebro-Computador , Encéfalo , Toma de Decisiones , Humanos , Toma de Decisiones/fisiología , Encéfalo/fisiología , Algoritmos , Electrocorticografía/métodos , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador
16.
Brain Res ; 1839: 149039, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38815645

RESUMEN

Musical emotions have received increasing attention over the years. To better recognize the emotions by brain-computer interface (BCI), the random music-playing and sequential music-playing experimental paradigms are proposed and compared in this paper. Two experimental paradigms consist of three positive pieces, three neutral pieces and three negative pieces of music. Ten subjects participate in two experimental paradigms. The features of electroencephalography (EEG) signals are firstly analyzed in the time, frequency and spatial domains. To improve the effect of emotion recognition, a recognition model is proposed with the optimal channels selecting by Pearson's correlation coefficient, and the feature fusion combining differential entropy and wavelet packet energy. According to the analysis results, the features of sequential music-playing experimental paradigm are more different among three emotions. The classification results of sequential music-playing experimental paradigm are also better, and its average results of positive, neutral and negative emotions are 78.53%, 72.81% and 77.35%, respectively. The more obvious the changes of EEG induced by the emotions, the higher the classification accuracy will be. After analyzing two experimental paradigms, a better way for music to induce the emotions can be explored. Therefore, our research offers a novel perspective on affective BCIs.


Asunto(s)
Interfaces Cerebro-Computador , Electroencefalografía , Emociones , Música , Humanos , Música/psicología , Emociones/fisiología , Electroencefalografía/métodos , Masculino , Femenino , Adulto Joven , Adulto , Encéfalo/fisiología , Percepción Auditiva/fisiología , Estimulación Acústica/métodos
17.
Front Robot AI ; 11: 1362735, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38694882

RESUMEN

We introduce a novel approach to training data augmentation in brain-computer interfaces (BCIs) using neural field theory (NFT) applied to EEG data from motor imagery tasks. BCIs often suffer from limited accuracy due to a limited amount of training data. To address this, we leveraged a corticothalamic NFT model to generate artificial EEG time series as supplemental training data. We employed the BCI competition IV '2a' dataset to evaluate this augmentation technique. For each individual, we fitted the model to common spatial patterns of each motor imagery class, jittered the fitted parameters, and generated time series for data augmentation. Our method led to significant accuracy improvements of over 2% in classifying the "total power" feature, but not in the case of the "Higuchi fractal dimension" feature. This suggests that the fit NFT model may more favorably represent one feature than the other. These findings pave the way for further exploration of NFT-based data augmentation, highlighting the benefits of biophysically accurate artificial data.

18.
J Neuroeng Rehabil ; 21(1): 91, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38812014

RESUMEN

BACKGROUND: The most challenging aspect of rehabilitation is the repurposing of residual functional plasticity in stroke patients. To achieve this, numerous plasticity-based clinical rehabilitation programs have been developed. This study aimed to investigate the effects of motor imagery (MI)-based brain-computer interface (BCI) rehabilitation programs on upper extremity hand function in patients with chronic hemiplegia. DESIGN: A 2010 Consolidated Standards for Test Reports (CONSORT)-compliant randomized controlled trial. METHODS: Forty-six eligible stroke patients with upper limb motor dysfunction participated in the study, six of whom dropped out. The patients were randomly divided into a BCI group and a control group. The BCI group received BCI therapy and conventional rehabilitation therapy, while the control group received conventional rehabilitation only. The Fugl-Meyer Assessment of the Upper Extremity (FMA-UE) score was used as the primary outcome to evaluate upper extremity motor function. Additionally, functional magnetic resonance imaging (fMRI) scans were performed on all patients before and after treatment, in both the resting and task states. We measured the amplitude of low-frequency fluctuation (ALFF), regional homogeneity (ReHo), z conversion of ALFF (zALFF), and z conversion of ReHo (ReHo) in the resting state. The task state was divided into four tasks: left-hand grasping, right-hand grasping, imagining left-hand grasping, and imagining right-hand grasping. Finally, meaningful differences were assessed using correlation analysis of the clinical assessments and functional measures. RESULTS: A total of 40 patients completed the study, 20 in the BCI group and 20 in the control group. Task-related blood-oxygen-level-dependent (BOLD) analysis showed that when performing the motor grasping task with the affected hand, the BCI group exhibited significant activation in the ipsilateral middle cingulate gyrus, precuneus, inferior parietal gyrus, postcentral gyrus, middle frontal gyrus, superior temporal gyrus, and contralateral middle cingulate gyrus. When imagining a grasping task with the affected hand, the BCI group exhibited greater activation in the ipsilateral superior frontal gyrus (medial) and middle frontal gyrus after treatment. However, the activation of the contralateral superior frontal gyrus decreased in the BCI group relative to the control group. Resting-state fMRI revealed increased zALFF in multiple cerebral regions, including the contralateral precentral gyrus and calcarine and the ipsilateral middle occipital gyrus and cuneus, and decreased zALFF in the ipsilateral superior temporal gyrus in the BCI group relative to the control group. Increased zReHo in the ipsilateral cuneus and contralateral calcarine and decreased zReHo in the contralateral middle temporal gyrus, temporal pole, and superior temporal gyrus were observed post-intervention. According to the subsequent correlation analysis, the increase in the FMA-UE score showed a positive correlation with the mean zALFF of the contralateral precentral gyrus (r = 0.425, P < 0.05), the mean zReHo of the right cuneus (r = 0.399, P < 0.05). CONCLUSION: In conclusion, BCI therapy is effective and safe for arm rehabilitation after severe poststroke hemiparesis. The correlation of the zALFF of the contralateral precentral gyrus and the zReHo of the ipsilateral cuneus with motor improvements suggested that these values can be used as prognostic measures for BCI-based stroke rehabilitation. We found that motor function was related to visual and spatial processing, suggesting potential avenues for refining treatment strategies for stroke patients. TRIAL REGISTRATION: The trial is registered in the Chinese Clinical Trial Registry (number ChiCTR2000034848, registered July 21, 2020).


Asunto(s)
Interfaces Cerebro-Computador , Imágenes en Psicoterapia , Imagen por Resonancia Magnética , Rehabilitación de Accidente Cerebrovascular , Accidente Cerebrovascular , Extremidad Superior , Humanos , Masculino , Rehabilitación de Accidente Cerebrovascular/métodos , Femenino , Persona de Mediana Edad , Extremidad Superior/fisiopatología , Imágenes en Psicoterapia/métodos , Accidente Cerebrovascular/fisiopatología , Accidente Cerebrovascular/complicaciones , Anciano , Adulto , Imaginación/fisiología , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/fisiopatología
19.
Sensors (Basel) ; 24(10)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38794022

RESUMEN

The widely adopted paradigm in brain-computer interfaces (BCIs) involves motor imagery (MI), enabling improved communication between humans and machines. EEG signals derived from MI present several challenges due to their inherent characteristics, which lead to a complex process of classifying and finding the potential tasks of a specific participant. Another issue is that BCI systems can result in noisy data and redundant channels, which in turn can lead to increased equipment and computational costs. To address these problems, the optimal channel selection of a multiclass MI classification based on a Fusion convolutional neural network with Attention blocks (FCNNA) is proposed. In this study, we developed a CNN model consisting of layers of convolutional blocks with multiple spatial and temporal filters. These filters are designed specifically to capture the distribution and relationships of signal features across different electrode locations, as well as to analyze the evolution of these features over time. Following these layers, a Convolutional Block Attention Module (CBAM) is used to, further, enhance EEG signal feature extraction. In the process of channel selection, the genetic algorithm is used to select the optimal set of channels using a new technique to deliver fixed as well as variable channels for all participants. The proposed methodology is validated showing 6.41% improvement in multiclass classification compared to most baseline models. Notably, we achieved the highest results of 93.09% for binary classes involving left-hand and right-hand movements. In addition, the cross-subject strategy for multiclass classification yielded an impressive accuracy of 68.87%. Following channel selection, multiclass classification accuracy was enhanced, reaching 84.53%. Overall, our experiments illustrated the efficiency of the proposed EEG MI model in both channel selection and classification, showing superior results with either a full channel set or a reduced number of channels.


Asunto(s)
Algoritmos , Interfaces Cerebro-Computador , Electroencefalografía , Redes Neurales de la Computación , Humanos , Electroencefalografía/métodos , Procesamiento de Señales Asistido por Computador , Imaginación/fisiología , Atención/fisiología
20.
J Neural Eng ; 21(3)2024 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-38812288

RESUMEN

Objective. Magnetoencephalography (MEG) shares a comparable time resolution with electroencephalography. However, MEG excels in spatial resolution, enabling it to capture even the subtlest and weakest brain signals for brain-computer interfaces (BCIs). Leveraging MEG's capabilities, specifically with optically pumped magnetometers (OPM-MEG), proves to be a promising avenue for advancing MEG-BCIs, owing to its exceptional sensitivity and portability. This study harnesses the power of high-frequency steady-state visual evoked fields (SSVEFs) to build an MEG-BCI system that is flickering-imperceptible, user-friendly, and highly accurate.Approach.We have constructed a nine-command BCI that operates on high-frequency SSVEF (58-62 Hz with a 0.5 Hz interval) stimulation. We achieved this by placing the light source inside and outside the magnetic shielding room, ensuring compliance with non-magnetic and visual stimulus presentation requirements. Five participants took part in offline experiments, during which we collected six-channel multi-dimensional MEG signals along both the vertical (Z-axis) and tangential (Y-axis) components. Our approach leveraged the ensemble task-related component analysis algorithm for SSVEF identification and system performance evaluation.Main Results.The offline average accuracy of our proposed system reached an impressive 92.98% when considering multi-dimensional conjoint analysis using data from both theZandYaxes. Our method achieved a theoretical average information transfer rate (ITR) of 58.36 bits min-1with a data length of 0.7 s, and the highest individual ITR reached an impressive 63.75 bits min-1.Significance.This study marks the first exploration of high-frequency SSVEF-BCI based on OPM-MEG. These results underscore the potential and feasibility of MEG in detecting subtle brain signals, offering both theoretical insights and practical value in advancing the development and application of MEG in BCI systems.


Asunto(s)
Interfaces Cerebro-Computador , Potenciales Evocados Visuales , Magnetoencefalografía , Estimulación Luminosa , Humanos , Magnetoencefalografía/métodos , Potenciales Evocados Visuales/fisiología , Adulto , Masculino , Femenino , Estimulación Luminosa/métodos , Adulto Joven , Corteza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...