Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Am J Sports Med ; 48(9): 2129-2136, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32551868

RESUMEN

BACKGROUND: Some studies reporting clinical outcomes after transosseous-equivalent (TOE) repair have attributed type II rotator cuff failure to excessive bridging suture tension, as it can cause overloading on the medial row. In a previous biomechanical cadaveric study, increasing bridging suture tension over 90 N did not improve the contact area and ultimate failure load of the TOE construct, despite increasing the contact force and contact pressure. PURPOSE: To compare the clinical outcomes of different bridging suture tensions after TOE rotator cuff repair based on the results of a previous biomechanical study. STUDY DESIGN: Randomized controlled trial; Level of evidence, 2. METHODS: A total of 78 patients who underwent arthroscopic rotator cuff repair for medium- to large-sized tears were prospectively enrolled and randomly divided into 2 groups according to the applied bridging suture tension: optimum tension group (96.3 ± 4.9 N) and maximum tension group (199.0 ± 20.3 N). Bridging suture tension was measured with a customized tensiometer, as used in the previous biomechanical study. The functional outcome was measured at the final follow-up (27.4 ± 5.9 months [range, 24-45 months]) using the visual analog scale for pain, American Shoulder and Elbow Surgeons score, Simple Shoulder Test, and Constant score, and the anatomic outcome was evaluated using magnetic resonance imaging or ultrasonography at least 12 months after surgery. RESULTS: Overall, 64 patients (32 in each group) were analyzed. The functional outcomes improved significantly compared with preoperative values (all P < .05) but did not show significant differences between the 2 groups (all P > .05). Regarding the anatomic outcomes, the maximum tension group (n = 1; 3.1%) had a significantly lower healing failure rate than the optimum tension group (n = 9; 28.1%) (P = .013). One patient in the maximum tension group had a type II failure. CONCLUSION: Maximum bridging suture tension in TOE repair for medium- to large-sized rotator cuff tears provided better anatomic healing with less risk of medial rotator cuff failure, which differs from the results of a previous time-zero biomechanical study.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Técnicas de Sutura , Artroscopía , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos , Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Anclas para Sutura , Suturas , Resultado del Tratamiento
2.
Neural Regen Res ; 12(12): 2077-2083, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29323049

RESUMEN

Peripheral nerve injury is a serious disease and its repair is challenging. A cable-style autologous graft is the gold standard for repairing long peripheral nerve defects; however, ensuring that the minimum number of transplanted nerve attains maximum therapeutic effect remains poorly understood. In this study, a rat model of common peroneal nerve defect was established by resecting a 10-mm long right common peroneal nerve. Rats receiving transplantation of the common peroneal nerve in situ were designated as the in situ graft group. Ipsilateral sural nerves (10-30 mm long) were resected to establish the one sural nerve graft group, two sural nerves cable-style nerve graft group and three sural nerves cable-style nerve graft group. Each bundle of the peroneal nerve was 10 mm long. To reduce the barrier effect due to invasion by surrounding tissue and connective-tissue overgrowth between neural stumps, small gap sleeve suture was used in both proximal and distal terminals to allow repair of the injured common peroneal nerve. At three months postoperatively, recovery of nerve function and morphology was observed using osmium tetroxide staining and functional detection. The results showed that the number of regenerated nerve fibers, common peroneal nerve function index, motor nerve conduction velocity, recovery of myodynamia, and wet weight ratios of tibialis anterior muscle were not significantly different among the one sural nerve graft group, two sural nerves cable-style nerve graft group, and three sural nerves cable-style nerve graft group. These data suggest that the repair effect achieved using one sural nerve graft with a lower number of nerve fibers is the same as that achieved using the two sural nerves cable-style nerve graft and three sural nerves cable-style nerve graft. This indicates that according to the 'multiple amplification' phenomenon, one small nerve graft can provide a good therapeutic effect for a large peripheral nerve defect.

3.
Am J Sports Med ; 43(9): 2118-25, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26150589

RESUMEN

BACKGROUND: Transosseous-equivalent (TOE) rotator cuff repair can increase contact area and contact pressure between the repaired cuff tendon and bony footprint and can show higher ultimate loads to failure and smaller gap formation compared with other repair techniques. However, it has been suggested that medial rotator cuff failure after TOE repair may result from increased bridging suture tension. PURPOSE: To determine optimum bridging suture tension in TOE repair by evaluating footprint contact and construct failure characteristics at different tensions. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 18 fresh-frozen cadaveric shoulders, randomly divided into 3 groups, were constructed with a TOE configuration using the same medial suture anchor and placing a Tekscan sensing pad between the repaired rotator cuff tendon and footprint. Nine of the 18 shoulders were used to measure footprint contact characteristics. With use of the Tekscan measurement system, the contact pressure and area between the rotator cuff tendon and greater tuberosity were quantified for bridging suture tensions of 60, 90, and 120 N with glenohumeral abduction angles of 0° and 30° and humeral rotation angles of 30° (internal), 0°, and 30° (external). TOE constructs of all 18 shoulders then underwent construct failure testing (cyclic loading and load to failure) to determine the yield load, ultimate load, stiffness, hysteresis, strain, and failure mode at 60 and 120 N of tension. RESULTS: As bridging suture tension increased, contact force, contact pressure, and peak pressure increased significantly at all positions (P < .05 for all). Regarding contact area, no significant differences were found between 90 and 120 N at all positions, although there were significant differences between 60 and 90 N. The construct failure test demonstrated no significant differences in any parameters according to various tensions (P > .05 for all). CONCLUSION: Increasing bridging suture tension to over 90 N did not improve contact area but did increase contact force and pressure. Bridging suture tension did not significantly affect ultimate failure loads. CLINICAL RELEVANCE: Considering the risks of overtensioning bridging sutures, it may be clinically more beneficial to keep bridging suture tension below 90 N.


Asunto(s)
Manguito de los Rotadores/cirugía , Técnicas de Sutura/normas , Suturas/normas , Adulto , Anciano , Artroplastia/métodos , Fenómenos Biomecánicos/fisiología , Bursitis/fisiopatología , Bursitis/cirugía , Cadáver , Estudios de Casos y Controles , Femenino , Humanos , Húmero/cirugía , Masculino , Persona de Mediana Edad , Presión , Proyectos de Investigación , Rotación , Manguito de los Rotadores/fisiología , Lesiones del Manguito de los Rotadores , Hombro/cirugía , Esguinces y Distensiones/fisiopatología , Esguinces y Distensiones/cirugía , Anclas para Sutura , Tendones/cirugía , Cicatrización de Heridas/fisiología
5.
Neural Regen Res ; 10(1): 84-9, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25788925

RESUMEN

Our previous study showed that systemic administration of the traditional Chinese medicine Epimedium extract promotes peripheral nerve regeneration. Here, we sought to explore the therapeutic effects of local administration of icariin, a major component of Epimedium extract, on peripheral nerve regeneration. A poly(lactic-co-glycolic acid) biological conduit sleeve was used to bridge a 5 mm right sciatic nerve defect in rats, and physiological saline, nerve growth factor, icariin suspension, or nerve growth factor-releasing microsphere suspension was injected into the defect. Twelve weeks later, sciatic nerve conduction velocity and the number of myelinated fibers were notably greater in the rats treated with icariin suspension or nerve growth factor-releasing microspheres than those that had received nerve growth factor or physiological saline. The effects of icariin suspension were similar to those of nerve growth factor-releasing microspheres. These data suggest that icariin acts as a nerve growth factor-releasing agent, and indicate that local application of icariin after spinal injury can promote peripheral nerve regeneration.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA