Resultados 1 - 20 de 34
Filtrar
1.
Forensic Sci Int ; 361: 112153, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39029141

RESUMEN

This study aimed to identify if biological material could be detected on the opposite side to deposition on fabric by commonly used presumptive and/or secondary tests. Additionally, this study aimed to ascertain if there is a difference in the DNA quantity and quality from samples obtained from both sides of the same substrate: cotton, polyester, denim, or combined viscose and polyester swatches. Blood, semen, or saliva (25 µL) was deposited on one side of 5 replicates of each fabric type and left for 24 h. Blood swatches were tested using Hemastix® and the ABACard® HemaTrace® immunoassay, semen swatches were tested using acid phosphatase (AP) reagent, the ABACard® p30® immunoassay and hematoxylin and eosin staining, and saliva swatches were tested using Phadebas® paper and the RSID-Saliva™ immunoassay. Both sides of each swatch were separately wet/dry swabbed and subjected to DNA analysis. Blood was able to be detected on the underside of all fabrics using both tests. Semen was able to be detected on the underside of swatches using the presumptive AP test but not p30®, and sperm was rarely observed. Saliva was able to be detected by RSID-Saliva™ but not Phadebas® paper when the underside of swatches were tested. Across all biological materials, DNA was able to be recovered from the top side of all 60 swatches. For the underside, DNA was able to be recovered from 54 swatches. Of the 6 swatches that DNA was unable to be recovered from, one sample was from semen and the rest were from saliva. This study has demonstrated that DNA and components of interest in forensically relevant biological material can be recovered from the opposite side to where it was originally deposited, and that observing biological material and/or DNA on one side of fabric does not definitively indicate direct deposition on that side.


Asunto(s)
Dermatoglifia del ADN , ADN , Saliva , Semen , Textiles , Saliva/química , Semen/química , Humanos , Masculino , Proyectos Piloto , ADN/análisis , Inmunoensayo , Sangre , Manchas de Sangre , Fosfatasa Ácida/análisis , Vestuario
2.
Clin Infect Dis ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38742844

RESUMEN

In a large, multi-regional cohort of African infants with HIV exposure, 44% of those with a positive HIV PCR lacked a confirmatory positive test. Efforts are needed to ensure high-fidelity implementation of HIV testing algorithms, so that all positive results are confirmed thereby reducing the risk of potentially false-positive results.

3.
J Fungi (Basel) ; 10(2)2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38392821

RESUMEN

Onychomycosis is an under-recognized healthcare burden. Despite the risk of misdiagnosis, confirmatory laboratory testing is under-utilized. Histopathologic examination with polymerase chain reaction (PCR) is currently the most effective diagnostic method; it offers direct detection and identification of a fungal invasion. In this retrospective cohort study, we assessed confirmatory testing results, with matching clinical diagnoses, in 96,293 nail specimens submitted during a 9-month period from 2022 to 2023. Toenail specimens were examined using fungal culture, histopathology and/or PCR. Clinical diagnoses were identified using the International Classification of Diseases 10th Revision codes. For clinically diagnosed onychomycosis patients, the overall positivity rate was 59.4%; a similar positivity rate (59.5%) was found in patients with clinically diagnosed non-fungal nail dystrophy. Performing a histopathologic examination with PCR was more likely to provide pathogen identification results than using fungal culture. Male patients had a higher rate of onychomycosis overall; however, female patients had more non-dermatophyte mold onychomycosis caused by Aspergillus. Clinically diagnosed onychomycosis patients with a co-diagnosis of tinea pedis were more likely to test positive for onychomycosis by PCR (odds ratio [OR]: 4.2; 95% confidence interval [CI]: 2.7-6.4), histopathology (OR: 2.5; 95% CI: 2.0-3.1) and fungal culture (OR: 3.2; 95% CI: 1.5-6.6). Our results support the use of confirmatory laboratory testing when there is a clinical diagnosis of onychomycosis.

4.
Vox Sang ; 119(3): 257-264, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38223953

RESUMEN

BACKGROUND AND OBJECTIVES: Serological HTLV-1/2 screening is mandatory for blood donor candidates in Brazil. Our objective was to analyse HTLV test results in blood donors submitted for screening and confirmatory assays in a Brazilian blood bank. MATERIALS AND METHODS: Retrospective analysis (2017-2022) results of chemiluminescence immunoassays and confirmatory tests for HTLV-1/2 in reactive donors were performed. During the analysed period, three sets of assays were used: (1) Architect rHTLV-I/II + HTLV Blot 2.4 (Western blot [WB]); (2) Alinity s HTLV I/II Reagent Kit + INNO-line immunoassay (LIA) HTLV I/II Score (LIA); (3) Alinity + WB. RESULTS: The analysed period comprised a total of 1,557,333 donations. The mean percentage of HTLV reactive donors using the Architect assay was 0.14%. With the change to the Alinity assay, that percentage dropped 2.3-fold (0.06%). The reactivity rate in the confirmatory tests (1064 samples) ranged from 13.5% to 30.2%, whereas 58.3%-85.9% of samples were non-reactive. The highest rates of positive (30.2%) and indeterminate (11.5%) results were seen using LIA. Considering all analysed samples, those with signal/cut-off ratio (S/CO) >50 were positive in confirmatory tests (positive predictive value, PPV = 100%), whereas samples with S/CO ≤6 are very unlikely to be truly positive (PPV = 0). CONCLUSION: The use of the Alinity assay reduced the frequency of false-positive results. Confirmatory tests are important to identify true HTLV infection in blood donors, because more than 58% of initially reactive individuals are confirmed as seronegative. Categorizing S/CO values is useful for assessing the likelihood of true HTLV-1/2 infection.


Asunto(s)
Infecciones por HTLV-I , Virus Linfotrópico T Tipo 1 Humano , Humanos , Donantes de Sangre , Estudios Retrospectivos , Virus Linfotrópico T Tipo 2 Humano , Western Blotting , Linfocitos T
5.
J Clin Microbiol ; 62(1): e0103923, 2024 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-38084950

RESUMEN

Supplementary nucleic acid amplification testing for Neisseria gonorrhoeae (NG) is widely used to circumvent specificity problems associated with extragenital sites. Here, we compared different supplementary approaches for confirming NG-positive samples from the cobas 4800 CT/NG (c4800) and cobas 6800 CT/NG (c6800) assays using the ResistancePlusGC (RP-GC) assay, which in addition to detecting NG, also predicts ciprofloxacin susceptibility via NG gyrA characterization. Two different nucleic acid extraction techniques were investigated for RP-GC detection; extracts from c4800 (c4800-RP-GC) and MagNA Pure 96 (MP96-RP-GC). NG-positive (n = 300) and -negative (n = 150) samples in cobas PCR media from routine c4800 testing were retrospectively retested with c4800, c6800, c4800-RP-GC, and MP96-RP-GC. Selected samples were also tested with Xpert CT/NG (Xpert) for discrepant analysis. The gyrA status was compared to ETEST ciprofloxacin susceptibility or non-susceptibility for recovered isolates (n = 63). Extragenital confirmatory rates were higher for MP96-RP-GC (131/140; 93.6%) compared to c4800-RP-GC (126/146; 86.3%), albeit not significantly (P = 0.6677). Of 9 samples testing positive by c6800 and negative by MP96-RP-GC, 7/9 (77.8%) were also negative by Xpert. By contrast, the number of samples returning a valid gyrA status was significantly (P = 0.0003) higher for MP96-RP-GC (270/293; 92.2%) compared to c4800-RP-GC (245/298; 82.2%). The overall MP96-RP-GC gyrA status correlated 98.4% (61/62) with the reported ciprofloxacin sensitive (35/36; 97.2%) or non-susceptible (26/26; 100%) phenotype. Improved RP-GC confirmatory rates and reported gyrA status were observed using MP96 nucleic acids compared to c4800 extracts. The data further highlight the ongoing need for NG supplemental testing for oropharyngeal samples.


Asunto(s)
Gonorrea , Ácidos Nucleicos , Humanos , Neisseria gonorrhoeae/genética , Ciprofloxacina/farmacología , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Gonorrea/diagnóstico
6.
J Cyst Fibros ; 22(1): 66-72, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35577746

RESUMEN

Objectives Cystic fibrosis (CF) is a debilitating genetic disorder that benefits from early detection. CF diagnosis relies on measuring elevated sweat chloride that is difficult in neonates with low sweat rates. We introduce a new method for sweat chloride determination from volume-limited specimens, and explore the potential utility of sweat bicarbonate in neonatal CF screening. Methods A rapid assay (< 5 min) was developed to analyze chloride and bicarbonate using capillary electrophoresis with indirect UV detection (CE-iUV). Pilocarpine-stimulated sweat samples from screen-positive CF infants were collected at two hospital sites, including confirmed CF (n = 12), CF screen-positive inconclusive diagnosis (n = 4), and unaffected non-CF cases (n = 37). All sweat chloride samples were analyzed by a coulometric titrator and CE-iUV, and the viability to measure acid-labile bicarbonate was also evaluated. Results Stability studies revealed that bicarbonate can be reliably assessed in sweat if acidification and heating were avoided. Method validation demonstrated that sweat chloride and bicarbonate were quantified with acceptable accuracy (recovery of 102%), precision (CV = 3.7%) and detection limits (∼ 0.1 mM). An inter-laboratory comparison confirmed a mean bias of 6.5% (n = 53) for sweat chloride determination by CE-iUV relative to a commercial chloridometer. However, sweat bicarbonate did not discriminate between CF and non-CF infants (AUC = 0.623, p = 0.215) unlike chloride (AUC = 1.00, p = 3.00 × 10-7). Conclusions CE-iUV offers a robust method for sweat chloride testing from presumptive CF infants that may reduce testing failure rates. However, sweat bicarbonate does not have clinical value in newborn CF diagnosis.


Asunto(s)
Fibrosis Quística , Recién Nacido , Lactante , Humanos , Fibrosis Quística/diagnóstico , Fibrosis Quística/genética , Cloruros/análisis , Bicarbonatos , Sudor/química , Tamizaje Neonatal/métodos , Electroforesis Capilar/métodos
7.
BMC Pediatr ; 22(1): 736, 2022 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-36572846

RESUMEN

BACKGROUND: Successful linkage to HIV services and initiation of antiretroviral treatment (ART) for children living with HIV (CLHIV) is critical to improve pediatric ART coverage. We aimed to assess confirmatory testing, linkage, and rapid ART initiation among newly diagnosed CLHIV in Ethiopia from the perspectives of caregivers and healthcare workers (HCWs). METHODS: We conducted standardized surveys with HCWs and caregivers of children 2-14 years who were diagnosed with HIV but not yet on ART who had been identified during a cross-sectional study in Ethiopia from May 2017-March 2018. Eight health facilities based on their HIV caseload and testing volume and 21 extension sites were included. Forty-one children, 34 care givers and 40 healthcare workers were included in this study. Three months after study enrollment, caregivers were surveyed about timing and experiences with HIV service enrollment, confirmatory testing, and ART initiation. Data collected from HCWs included perceptions of confirmatory testing in CLHIV before ART initiation. SPSS was used to conduct descriptive statistics. RESULTS: The majority of the 41 CLHIV were enrolled to HIV services (n = 34, 83%) and initiated ART by three months (n = 32, 94%). Median time from diagnosis to ART initiation was 12 days (interquartile range 5-18). Five children died before the follow-up interview. Confirmatory HIV testing was conducted in 34 children and found no discordant results; the majority (n = 23, 68%) received it within one week of HIV diagnosis. Almost all HCWs (n = 39/40, 98%) and caregivers (n = 31/34, 91%) felt better/the same about test results after conducting confirmatory testing. CONCLUSION: Opportunities remain to strengthen linkage for newly diagnosed CLHIV in Ethiopia through intensifying early follow-up to ensure prompt confirmatory testing and rapid ART initiation. Additional services could help caregivers with decision-making around treatment initiation for their children.


Asunto(s)
Fármacos Anti-VIH , Infecciones por VIH , Niño , Humanos , Cuidadores , Etiopía , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , Estudios Transversales , Antirretrovirales/uso terapéutico , Personal de Salud , Prueba de VIH , Fármacos Anti-VIH/uso terapéutico
8.
Viruses ; 14(11)2022 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-36423154

RESUMEN

The hepatitis B virus (HBV) remains a high priority for Chinese blood banks due to the high prevalence of infection. HBV blood safety has been significantly improved by the implementation of highly sensitive and specific serological and molecular HBV screening assays. The multiplication of viral markers tested and the ever-increasing analytical sensitivity of the tests can make the interpretation of the results difficult. False-positive or indeterminate results may lead to permanent donor deferrals and conflicts between donors and blood banks. To avoid blood shortages, blood services aim to limit unnecessary donor losses by developing procedures for the re-entry of donors temporarily deferred due to an unconfirmed HBV reactivity. The development of such procedures based on donor follow-up and HBV confirmation remains limited. A review of the scarce data available revealed considerable heterogeneity in testing methods and re-entry algorithms, limited validation studies, and a lack of accurate assessment of the residual infectious risk potentially associated with donor re-entry. In conclusion, systematic and widely validated confirmatory testing and prolonged follow-up are essential for safe re-entry of temporary deferred donors. Standardization of HBV testing methods and the establishment of dedicated expert laboratories are needed because of the complexity of HBV infection in blood donors.


Asunto(s)
Donantes de Sangre , Hepatitis B , Humanos , Virus de la Hepatitis B , Hepatitis B/prevención & control , Anticuerpos contra la Hepatitis B , China/epidemiología
9.
Afr J Lab Med ; 11(1): 1485, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35811753

RESUMEN

Background: Early diagnosis and confirmation of HIV infection in newborns is crucial for expedited initiation of antiretroviral therapy. Confirmatory testing must be done for all children with a reactive HIV PCR result. There is no comprehensive data on confirmatory testing and HIV PCR test request rejections at National Health Laboratory Service laboratories in South Africa. Objective: This study assessed the metrics of routine infant HIV PCR testing at the Tygerberg Hospital Virology Laboratory, Cape Town, Western Cape, South Africa, including the proportion of rejected test requests, turn-around time (TAT), and rate of confirmatory testing. Methods: We retrospectively reviewed laboratory-based data on all HIV PCR tests performed on children ≤ 24 months old (n = 43 346) and data on rejected HIV PCR requests (n = 1479) at the Tygerberg virology laboratory over two years (2017-2019). Data from sample collection to release of results were analysed to assess the TAT and follow-up patterns. Results: The proportion of rejected HIV PCR requests was 3.3%; 83.9% of these were rejected for various pre-analytical reasons. Most of the test results (89.2%) met the required 96-h TAT. Of the reactive initial test results, 53.5% had a follow-up sample tested, of which 93.1% were positive. Of the initial indeterminate results, 74.7% were negative on follow-up testing. Conclusion: A high proportion of HIV PCR requests were rejected for pre-analytical reasons. The high number of initial reactive tests without evidence of follow-up suggests that a shorter TAT is required to allow confirmatory testing before children are discharged.

10.
Afr. j. lab. med. (Print) ; 11(1): 1-7, 2022. tables, figures
Artículo en Inglés | AIM (África) | ID: biblio-1378853

RESUMEN

Background: Early diagnosis and confirmation of HIV infection in newborns is crucial for expedited initiation of antiretroviral therapy. Confirmatory testing must be done for all children with a reactive HIV PCR result. There is no comprehensive data on confirmatory testing and HIV PCR test request rejections at National Health Laboratory Service laboratories in South Africa.Objective: This study assessed the metrics of routine infant HIV PCR testing at the Tygerberg Hospital Virology Laboratory, Cape Town, Western Cape, South Africa, including the proportion of rejected test requests, turn-around time (TAT), and rate of confirmatory testing.Methods: We retrospectively reviewed laboratory-based data on all HIV PCR tests performed on children ≤ 24 months old (n = 43346) and data on rejected HIV PCR requests (n = 1479) at the Tygerberg virology laboratory over two years (2017­2019). Data from sample collection to release of results were analysed to assess the TAT and follow-up patterns.Results: The proportion of rejected HIV PCR requests was 3.3%; 83.9% of these were rejected for various pre-analytical reasons. Most of the test results (89.2%) met the required 96-h TAT. Of the reactive initial test results, 53.5% had a follow-up sample tested, of which 93.1% were positive. Of the initial indeterminate results, 74.7% were negative on follow-up testing.Conclusion: A high proportion of HIV PCR requests were rejected for pre-analytical reasons. The high number of initial reactive tests without evidence of follow-up suggests that a shorter TAT is required to allow confirmatory testing before children are discharged.


Asunto(s)
Diagnóstico Precoz , Lactante , Reacción en Cadena de la Polimerasa , VIH , Cuidados Posteriores , Técnicas de Laboratorio Clínico , Técnicas y Procedimientos Diagnósticos , Terapia Antirretroviral Altamente Activa
11.
J Clin Virol ; 136: 104762, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33607351

RESUMEN

BACKGROUND: Confirmatory testing of SARS-CoV-2 results is essential to reduce false positives, but comes at a cost of significant extra workload for laboratories and increased turnaround time. A balance must be sought. We analysed our confirmatory testing pathway to produce a more refined approach in preparation for rising case numbers. METHODS: Over a 10-week low prevalence period we performed confirmatory testing on all newly positive results. Turnaround time was measured and results were analysed to identify a threshold that could be applied as a cut-off for future confirmatory testing and reduce overall workload for the laboratory. RESULTS: Between 22/06/20 and 31/08/20 confirmatory testing was performed on 108 newly positive samples, identifying 32 false positive results (30 %). Turnaround time doubled, increasing by an extra 17 h. There was a highly statistically significant difference between initial Relative Light Unit (RLU) of results that confirmed compared to those that did not, 1176 vs 721 (P < 0.00001). RLU = 1000 was identified as a suitable threshold for confirmatory testing in our laboratory: with RLU ≥ 1000, 55/56 (98 %) confirmed as positive, whereas with RLU < 1000 only 12/38 (32 %) confirmed. CONCLUSIONS: False positive SARS-CoV-2 tests can be identified by confirmatory testing, yet this may significantly delay results. Establishing a threshold for confirmatory testing streamlines this process to focus only on samples where it is most required. We advise all laboratories to follow a similar process to identify thresholds that trigger confirmatory testing for their own assays, increasing accuracy while maintaining efficiency for when case numbers are high.


Asunto(s)
Prueba de COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Reacciones Falso Negativas , Reacciones Falso Positivas , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Sensibilidad y Especificidad
12.
J Clin Endocrinol Metab ; 106(4): e1708-e1716, 2021 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-33377974

RESUMEN

CONTEXT: The diagnostic work-up of primary aldosteronism (PA) includes screening and confirmation steps. Case confirmation is time-consuming, expensive, and there is no consensus on tests and thresholds to be used. Diagnostic algorithms to avoid confirmatory testing may be useful for the management of patients with PA. OBJECTIVE: Development and validation of diagnostic models to confirm or exclude PA diagnosis in patients with a positive screening test. DESIGN, PATIENTS, AND SETTING: We evaluated 1024 patients who underwent confirmatory testing for PA. The diagnostic models were developed in a training cohort (n = 522), and then tested on an internal validation cohort (n = 174) and on an independent external prospective cohort (n = 328). MAIN OUTCOME MEASURE: Different diagnostic models and a 16-point score were developed by machine learning and regression analysis to discriminate patients with a confirmed diagnosis of PA. RESULTS: Male sex, antihypertensive medication, plasma renin activity, aldosterone, potassium levels, and the presence of organ damage were associated with a confirmed diagnosis of PA. Machine learning-based models displayed an accuracy of 72.9%-83.9%. The Primary Aldosteronism Confirmatory Testing (PACT) score correctly classified 84.1% at training and 83.9% or 81.1% at internal and external validation, respectively. A flow chart employing the PACT score to select patients for confirmatory testing correctly managed all patients and resulted in a 22.8% reduction in the number of confirmatory tests. CONCLUSIONS: The integration of diagnostic modeling algorithms in clinical practice may improve the management of patients with PA by circumventing unnecessary confirmatory testing.


Asunto(s)
Hiperaldosteronismo/diagnóstico , Femenino , Humanos , Aprendizaje Automático , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Sensibilidad y Especificidad
13.
Eur J Clin Microbiol Infect Dis ; 40(1): 67-75, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32767178

RESUMEN

Supplementary nucleic acid amplification tests for Neisseria gonorrhoeae (NG) are widely used to circumvent specificity problems often associated with extragenital sites. This study was prompted by our observations and concerns from local sexual health physicians over increased discrepancies between Roche cobas 4800 CT/NG (c4800) and our in-house supplementary NG-PCR (NG-duplex) for oropharyngeal samples, when compared with Abbott RealTime CT/NG (m2000) performed prior. Here, we investigated these differences. Three banks of NG-positive samples were used. Bank 1 (n = 344) were screened using m2000. Banks 2 (n = 344) and 3 (n = 400) were screened using c4800. Remnant nucleic acids from all banks were tested using NG-duplex as part of routine testing. Bank 2 samples were further tested using m2000, some selectively tested using Cepheid Xpert CT/NG. Bank 3 samples were further tested using cobas CT/NG (cobas 6800 system). Confirmatory rates were significantly (p < 0.0001) higher for m2000 compared with c4800, with oropharyngeal samples the key difference. However, we also showed that our NG-duplex failed to confirm some true-positive NG samples. Using an expanded gold standard, confirmatory rates for m2000 and c4800 exceeded 90% for all anatomical sites with the exception of c4800 for oropharyngeal specimens at 78%. The observed discrepancies were due to a combination of c4800 producing false-positive results for oropharyngeal samples as well as sensitivity issues related to the NG-duplex assay. The data highlight the ongoing need for NG supplemental nucleic acid testing for oropharyngeal samples but also emphasise the need for careful selection of supplementary methods.


Asunto(s)
Gonorrea/diagnóstico , Neisseria gonorrhoeae/genética , Gonorrea/microbiología , Humanos , Técnicas de Amplificación de Ácido Nucleico , Orofaringe/microbiología , Reacción en Cadena de la Polimerasa , Sensibilidad y Especificidad
14.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-1003999

RESUMEN

【Objective】 To confirm Hepatitis B virus (HBV) infections and identify infection status by excluding false positive in blood donors reactive to nucleic acid testing (NAT) but without serological markers (Seroneg-NAT). 【Methods】 Seroneg-NAT yields were selected among blood donors in Dalian Blood Center from November 1, 2010 to February 28, 2021, and their HBV DNA was further confirmed with TaqMan HBV DNA quantification or virions concentration by polyethylene glycol (PEG) precipitation combined with in-house nested PCR targeting the S, BCP, PreS/S and Precore/core regions of the viral genome, and follow-up test was carried out, including blood routine screening and HBsAg, anti-HBs and anti-HBc testing. HBV infection was confirmed by HBV DNA yielding and anti-HBs/anti-HBc seroconversion in follow-up testing, and HBV DNA was further sequenced if necessary. 【Results】 During the period of 10 years and 4 months, 0.03% (126/466 911) Seroneg-NAT yields were selected, of which 46.8% (59/126) were HBV DNA+ and 53.2% (67/126) were unconfirmed. Among 126 Seroneg-NAT yields, 40.5% (51/126) were involved in follow-up test, of which 28 were HBV DNA+ and 23 were unconfirmed. HBV infections were confirmed in 48% (60/126) of Seroneg-NAT yields. Of follow-up donors, 54.9% (28/51) were identified as early infection before seroconversion, 2.0% (1/51) seronegative occult HBV infection (OBI), and 37.3% (19/51) NAT false positive. There were still 5.9% (3/51) classified as the indetermination. 【Conclusion】 Nearly half Seroneg-NAT yields in Dalian blood donors were infected with HBV and more than 50% were early infections before seroconversion. The majority of HBV DNA unconfirmed without serological markers were false positives.

15.
Wiad Lek ; 73(6): 1211-1216, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32723955

RESUMEN

OBJECTIVE: The aim: To compose an applicable diagnostic checklist for neonatologists, pediatricians, and general practitioners who refer newborns with certain inherited metabolic diseases (IMDs) suspicion to confirmatory testing laboratories. PATIENTS AND METHODS: Materials and methods: Analyzed international and generally, known national clinical guides and recommendations devoted to IMDs diagnostics, treatment and follow up. RESULTS: Results: Considering integral character of the diagnostic work-up of inborn errors of metabolism, authors of this article composed an applicable checklist that comprises set of data necessary for interpretation the positive results of expanded newborn screening and making decision of appropriate biochemical and molecular tests are required for confirmatory follow-up testing to establish the diagnosis and prescribe pathogenetic therapy. CONCLUSION: Conclusions: Properly filled checklist allow metabolic professionals to select appropriate confirmatory tests and interpret results obtained. Early IMDs diagnosis and prompt treatment initiation are crucial for positive outcomes and proved to be an effective tool to decrease levels of child disability and infant mortality.


Asunto(s)
Enfermedades Metabólicas/diagnóstico , Errores Innatos del Metabolismo/diagnóstico , Niño , Diagnóstico Diferencial , Humanos , Lactante , Recién Nacido , Tamizaje Neonatal , Pediatras
17.
J Thromb Haemost ; 18(11): 2828-2839, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33462974

RESUMEN

This guidance focuses on methodological aspects of lupus anticoagulant (LA) testing, as well as interpretation of results for clinicians. The main changes in how to test for LA compared with the International Society on Thrombosis and Haemostasis Scientific and Standardization Committee 2009 guidelines, in the preanalytical phase are more detailed recommendations on how to handle testing in anticoagulated patients, and the timing of testing. Also, routine coagulation tests are advised to obtain more information on the coagulation background of the patient, and when necessary, anti-Xa activity measurement for heparins or specific assays for direct oral anticoagulants should be performed. The three-step procedure with two test systems (diluted Russell's viper venom time and activated partial thromboplastin time [aPTT]) is essentially not changed. Silica remains the preferable activator in the aPTT assays, but ellagic acid is not excluded. We advise simultaneous performance of the mixing and confirmatory step, in each sample with a prolonged screening test. The confirmatory step can also be performed on a mixture of patient plasma and normal pooled plasma. Cutoff values should be established in-house on at least 120 normals, with transference of the manufacturer's cutoffs as an alternative. Reporting of results has not been changed, although more attention is focused on what clinicians should know. Patient selection for LA testing has been expanded.


Asunto(s)
Síndrome Antifosfolípido , Trombosis , Síndrome Antifosfolípido/diagnóstico , Pruebas de Coagulación Sanguínea , Humanos , Inhibidor de Coagulación del Lupus , Tiempo de Tromboplastina Parcial , Tiempo de Protrombina , Estándares de Referencia , Trombosis/diagnóstico
18.
Kidney360 ; 1(10): 1148-1156, 2020 10 29.
Artículo en Inglés | MEDLINE | ID: mdl-35368778

RESUMEN

Nearly seven decades have elapsed since the clinical and biochemical features of primary hyperaldosteronism (PA) were described by Conn. PA is now widely recognized as the most common form of secondary hypertension. PA has a strong correlation with cardiovascular disease and failure to recognize and/or properly diagnose this condition has profound health consequences. With proper identification and management, PA has the potential to be surgically cured in a proportion of affected individuals. The diagnostic pursuit for PA is not a simplistic endeavor, particularly because an enhanced understanding of the disease process is continually redefining the diagnostic and treatment algorithm. These new concepts have emerged in all areas of this clinical condition, including identification, diagnosis, and treatment. Here, we review the recent advances in this field and summarize the effect these advances have on both diagnostic and therapeutic modalities.


Asunto(s)
Hiperaldosteronismo , Hipertensión , Adrenalectomía/efectos adversos , Aldosterona/uso terapéutico , Humanos , Hiperaldosteronismo/diagnóstico , Hipertensión/diagnóstico , Renina/uso terapéutico
19.
J Clin Endocrinol Metab ; 105(4)2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31665338

RESUMEN

CONTEXT: The current clinical guidelines suggest that confirmatory tests for primary aldosteronism (PA) may be excluded in some of patients who have elevated plasma aldosterone concentration (PAC) under plasma renin suppression. However, this has low-priority evidence and is under debate in use of serum potassium. OBJECTIVE: This study aimed to investigate an appropriate setting for sparing confirmatory tests in PA. DESIGN AND SETTING: A retrospective cross-sectional study in a single referral center. PARTICIPANTS: This study included 327 patients who had hypertension under plasma renin suppression and underwent the captopril challenge test (CCT) between January 2007 and April 2019. CCT results were used to diagnose PA. MAIN OUTCOME MEASURE: Diagnostic value of PAC and serum potassium in confirmation of PA. RESULTS: Of the studied patients, 252 of 327 (77%) were diagnosed with PA. All 61 patients with PAC > 30 ng/dL were diagnosed with PA. In patients with PAC between 20 and 30 ng/dL, 44 of 55 (80%) were diagnosed with PA, while all 26 with PAC between 20 to 30 ng/dL who had spontaneous hypokalemia were diagnosed with PA. The proportion of unilateral PA determined by adrenal vein sampling (AVS) was higher in patients who had PAC > 30 ng/dL or those with spontaneous hypokalemia who had PAC between 20 and 30 ng/dL than those who did not meet the criteria (76% vs. 17%, P < .001). CONCLUSION: Confirmatory tests in PA could be spared in patients who have typical features of PA and these patients had a high probability of unilateral PA on AVS.


Asunto(s)
Aldosterona/sangre , Biomarcadores/sangre , Hiperaldosteronismo/diagnóstico , Potasio/sangre , Guías de Práctica Clínica como Asunto/normas , Adulto , Anciano , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Hiperaldosteronismo/sangre , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos
20.
BMC Med Genomics ; 12(1): 138, 2019 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-31623605

RESUMEN

BACKGROUND: Healthcare providers increasingly use information about pathogenic variants in cancer predisposition genes, including sequence variants and large rearrangements (LRs), in medical management decisions. While sequence variant detection is typically robust, LRs can be difficult to detect and characterize and may be underreported as a cause for hereditary cancer risk. This report describes the outcomes of hereditary cancer genetic testing using a comprehensive strategy that employs next-generation sequencing (NGS) for LR detection, coupled with LR confirmation using repeat hybrid capture NGS, microarray comparative genomic hybridization (microarray-CGH), and/or multiplex ligation-dependent probe amplification (MLPA). METHODS: Sequencing and LR analysis were conducted in a consecutive series of 376,159 individuals who received clinical testing with a hereditary pan-cancer gene panel from September 2013 through May 2017. NGS dosage analysis was used to evaluate potential deletions or duplications, with controls in place to exclude pseudogene reads. Samples positive for a putative LR based on NGS were confirmed using a comprehensive approach that included targeted microarray-CGH and/or MLPA analysis, with further examination as needed to ascertain the nature of the LR. RESULTS: A total of 3461 LRs were identified and classified as a deleterious mutation (DM), suspected deleterious mutation (SDM) or variant of uncertain significance. Pathogenic LRs (DM/SDM) accounted for the majority of LRs (67.7%), the largest proportion of which were deletions (86.1%), followed by duplications (11.3%), insertions (1.8%), triplications (0.5%), and inversions (0.3%). Several cases presented illustrate that the laboratory approach employed here can ensure consistent identification and accurate characterization of LRs. In the absence of this comprehensive testing strategy, 9% of LRs identified in this testing population might have been missed, potentially leading to inappropriate medical management in as many as 210 individuals referred for hereditary cancer testing. CONCLUSIONS: These data show that copy number analysis using NGS coupled with confirmatory testing reliably detects and characterizes LRs. Further, LRs comprise a substantial proportion (7.2%) of pathogenic variants identified by the test. A robust and accurate LR identification strategy is an essential component of a high-quality genetic testing program, enabling clinicians to optimize patient medical management decisions.


Asunto(s)
Reordenamiento Génico , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Neoplasias/genética , Estudios de Casos y Controles , Hibridación Genómica Comparativa , Variaciones en el Número de Copia de ADN , Duplicación de Gen , Humanos , Mutagénesis Insercional , Neoplasias/diagnóstico , Análisis de Secuencia de ADN , Eliminación de Secuencia
SELECCIÓN DE REFERENCIAS