1.
J Clin Med ; 13(14)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-39064059

RESUMEN

Patient self-inflicted lung injury (P-SILI) is a major challenge for the ICU physician: although spontaneous breathing is associated with physiological benefits, in patients with acute respiratory distress syndrome (ARDS), the risk of uncontrolled inspiratory effort leading to additional injury needs to be assessed to avoid delayed intubation and increased mortality. In the present review, we analyze the available clinical and experimental evidence supporting the existence of lung injury caused by uncontrolled high inspiratory effort, we discuss the pathophysiological mechanisms by which increased effort causes P-SILI, and, finally, we consider the measurements and interpretation of bedside physiological measures of increased drive that should alert the clinician. The data presented in this review could help to recognize injurious respiratory patterns that may trigger P-SILI and to prevent it.

2.
Respir Care ; 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38866417

RESUMEN

BACKGROUND: Patients with a tracheostomy and difficult weaning from invasive mechanical ventilation constitute a challenging problem in critical care. An increased duration of ventilation may lead to diaphragmatic dysfunction and a noninvasive assessment of the diaphragm, such as ultrasound, attracts interest in the clinical practice. We evaluated the relationship of ultrasound-derived indices with weaning outcome and with established indices of respiratory strength and load in subjects who are tracheostomized and undergoing weaning. METHODS: This prospective study was conducted at an academic ICU in Greece. Twenty subjects with tracheostomy and difficult weaning, during a spontaneous breathing trial, underwent time synchronous diaphragmatic sonography and esophageal manometry, to assess diaphragmatic excursion and thickening fraction, esophageal and transdiaphragmatic pressures, pressure-time product of the esophageal pressure, and maximum inspiratory pressure. The primary outcome was liberation from mechanical ventilation at 48 h. The relationship of diaphragmatic ultrasound with esophageal pressure-derived indices was also evaluated. RESULTS: Weaning from invasive ventilation failed in 10 subjects. Diaphragmatic excursion exhibited a significant difference between weaning success and failure (1.34 ± 0.56 versus 0.79 ± 0.44; P = .044), a strong correlation with transdiaphragmatic pressure (r = 0.7, P = .02), and a moderate correlation with the pressure-time product of the esophageal pressure (r = 0.65, P = .02) and the maximum inspiratory pressure (r = 0.66, P = .02). Transdiaphragmatic pressure presented the highest area under the curve (0.97). However, when transdiaphragmatic pressure was compared with diaphragmatic excursion (area under the curve, 0.84) for predictive accuracy, no significant difference was found. CONCLUSIONS: Diaphragmatic excursion is a valuable tool for the assessment of diaphragmatic strength, respiratory load, and weaning prediction.

3.
Front Pediatr ; 12: 1383689, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38832000

RESUMEN

Introduction: Although neonatal breathing patterns vary after perinatal asphyxia, whether they change during therapeutic hypothermia (TH) remains unclear. We characterized breathing patterns in infants during TH for hypoxic-ischemic encephalopathy (HIE) and normothermia after rewarming. Methods: In seventeen spontaneously breathing infants receiving TH for HIE and in three who did not receive TH, we analyzed respiratory flow and esophageal pressure tracings for respiratory timing variables, pulmonary mechanics and respiratory effort. Breaths were classified as braked (inspiratory:expiratory ratio ≥1.5) and unbraked (<1.5). Results: According to the expiratory flow shape braked breaths were chategorized into early peak expiratory flow, late peak expiratory flow, slow flow, and post-inspiratory hold flow (PiHF). The most braked breaths had lower rates, larger tidal volume but lower minute ventilation, inspiratory airway resistance and respiratory effort, except for the PiHF, which had higher resistance and respiratory effort. The braked pattern predominated during TH, but not during normothermia or in the uncooled infants. Conclusions: We speculate that during TH for HIE low respiratory rates favor neonatal braked breathing to preserve lung volume. Given the generally low respiratory effort, it seems reasonable to leave spontaneous breathing unassisted. However, if the PiHF pattern predominates, ventilatory support may be required.

4.
Front Bioeng Biotechnol ; 12: 1280679, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38784763

RESUMEN

Background: The incidence of blast lung injury (BLI) has been escalating annually due to military conflicts and industrial accidents. Currently, research into these injuries predominantly uses animal models. Despite the availability of various models, there remains a scarcity of studies focused on monitoring respiratory mechanics post-BLI. Consequently, our objective was to develop a model for monitoring esophageal pressure (Pes) following BLI using a biological shock tube (BST), aimed at providing immediate and precise monitoring of respiratory mechanics parameters post-injury. Methods: Six pigs were subjected to BLI using a BST, during which Pes was monitored. We assessed vital signs; conducted blood gas analysis, hemodynamics evaluations, and lung ultrasound; and measured respiratory mechanics before and after the inflicted injury. Furthermore, the gross anatomy of the lungs 3 h post-injury was examined, and hematoxylin and eosin staining was conducted on the injured lung tissues for further analysis. Results: The pressure in the experimental section of the BST reached 402.52 ± 17.95 KPa, with a peak pressure duration of 53.22 ± 1.69 ms. All six pigs exhibited an anatomical lung injury score ≥3, and pathology revealed classic signs of severe BLI. Post-injury vital signs showed an increase in HR and SI, along with a decrease in MAP (p < 0.05). Blood gas analyses indicated elevated levels of Lac, CO2-GAP, A-aDO2, HB, and HCT and reduced levels of DO2, OI, SaO2, and OER (p < 0.05). Hemodynamics and lung ultrasonography findings showed increased ELWI, PVPI, SVRI, and lung ultrasonography scores and decreased CI, SVI, GEDI, and ITBI (p < 0.05). Analysis of respiratory mechanics revealed increased Ppeak, Pplat, Driving P, MAP, PEF, Ri, lung elastance, MP, Ptp, Ppeak - Pplat, and ΔPes, while Cdyn, Cstat, and time constant were reduced (p < 0.05). Conclusion: We have successfully developed a novel respiratory mechanics monitoring model for severe BLI. This model is reliable, repeatable, stable, effective, and user-friendly. Pes monitoring offers a non-invasive and straightforward alternative to blood gas analysis, facilitating early clinical decision-making. Our animal study lays the groundwork for the early diagnosis and management of severe BLI in clinical settings.

5.
J Clin Med ; 13(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38731069

RESUMEN

Advanced respiratory monitoring encompasses a diverse range of mini- or noninvasive tools used to evaluate various aspects of respiratory function in patients experiencing acute respiratory failure, including those requiring extracorporeal membrane oxygenation (ECMO) support. Among these techniques, key modalities include esophageal pressure measurement (including derived pressures), lung and respiratory muscle ultrasounds, electrical impedance tomography, the monitoring of diaphragm electrical activity, and assessment of flow index. These tools play a critical role in assessing essential parameters such as lung recruitment and overdistention, lung aeration and morphology, ventilation/perfusion distribution, inspiratory effort, respiratory drive, respiratory muscle contraction, and patient-ventilator synchrony. In contrast to conventional methods, advanced respiratory monitoring offers a deeper understanding of pathological changes in lung aeration caused by underlying diseases. Moreover, it allows for meticulous tracking of responses to therapeutic interventions, aiding in the development of personalized respiratory support strategies aimed at preserving lung function and respiratory muscle integrity. The integration of advanced respiratory monitoring represents a significant advancement in the clinical management of acute respiratory failure. It serves as a cornerstone in scenarios where treatment strategies rely on tailored approaches, empowering clinicians to make informed decisions about intervention selection and adjustment. By enabling real-time assessment and modification of respiratory support, advanced monitoring not only optimizes care for patients with acute respiratory distress syndrome but also contributes to improved outcomes and enhanced patient safety.

6.
BMC Pulm Med ; 24(1): 212, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38693506

RESUMEN

BACKGROUND: Patient-ventilator asynchrony commonly occurs during pressure support ventilation (PSV). IntelliSync + software (Hamilton Medical AG, Bonaduz, Switzerland) is a new ventilation technology that continuously analyzes ventilator waveforms to detect the beginning and end of patient inspiration in real time. This study aimed to evaluate the physiological effect of IntelliSync + software on inspiratory trigger delay time, delta airway (Paw) and esophageal (Pes) pressure drop during the trigger phase, airway occlusion pressure at 0.1 s (P0.1), and hemodynamic variables. METHODS: A randomized crossover physiologic study was conducted in 14 mechanically ventilated patients under PSV. Patients were randomly assigned to receive conventional flow trigger and cycling, inspiratory trigger synchronization (I-sync), cycle synchronization (C-sync), and inspiratory trigger and cycle synchronization (I/C-sync) for 15 min at each step. Other ventilator settings were kept constant. Paw, Pes, airflow, P0.1, respiratory rate, SpO2, and hemodynamic variables were recorded. The primary outcome was inspiratory trigger and cycle delay time between each intervention. Secondary outcomes were delta Paw and Pes drop during the trigger phase, P0.1, SpO2, and hemodynamic variables. RESULTS: The time to initiate the trigger was significantly shorter with I-sync compared to baseline (208.9±91.7 vs. 301.4±131.7 msec; P = 0.002) and I/C-sync compared to baseline (222.8±94.0 vs. 301.4±131.7 msec; P = 0.005). The I/C-sync group had significantly lower delta Paw and Pes drop during the trigger phase compared to C-sync group (-0.7±0.4 vs. -1.2±0.8 cmH2O; P = 0.028 and - 1.8±2.2 vs. -2.8±3.2 cmH2O; P = 0.011, respectively). No statistically significant differences were found in cycle delay time, P0.1 and other physiological variables between the groups. CONCLUSIONS: IntelliSync + software reduced inspiratory trigger delay time compared to the conventional flow trigger system during PSV mode. However, no significant improvements in cycle delay time and other physiological variables were observed with IntelliSync + software. TRIAL REGISTRATION: This study was registered in the Thai Clinical Trial Registry (TCTR20200528003; date of registration 28/05/2020).


Asunto(s)
Estudios Cruzados , Programas Informáticos , Humanos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Respiración con Presión Positiva/métodos , Hemodinámica , Respiración Artificial/métodos , Frecuencia Respiratoria
7.
Pulmonology ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38760225

RESUMEN

INTRODUCTION AND OBJECTIVES: Quantifying breathing effort in non-intubated patients is important but difficult. We aimed to develop two models to estimate it in patients treated with high-flow oxygen therapy. PATIENTS AND METHODS: We analyzed the data of 260 patients from previous studies who received high-flow oxygen therapy. Their breathing effort was measured as the maximal deflection of esophageal pressure (ΔPes). We developed a multivariable linear regression model to estimate ΔPes (in cmH2O) and a multivariable logistic regression model to predict the risk of ΔPes being >10 cmH2O. Candidate predictors included age, sex, diagnosis of the coronavirus disease 2019 (COVID-19), respiratory rate, heart rate, mean arterial pressure, the results of arterial blood gas analysis, including base excess concentration (BEa) and the ratio of arterial tension to the inspiratory fraction of oxygen (PaO2:FiO2), and the product term between COVID-19 and PaO2:FiO2. RESULTS: We found that ΔPes can be estimated from the presence or absence of COVID-19, BEa, respiratory rate, PaO2:FiO2, and the product term between COVID-19 and PaO2:FiO2. The adjusted R2 was 0.39. The risk of ΔPes being >10 cmH2O can be predicted from BEa, respiratory rate, and PaO2:FiO2. The area under the receiver operating characteristic curve was 0.79 (0.73-0.85). We called these two models BREF, where BREF stands for BReathing EFfort and the three common predictors: BEa (B), respiratory rate (RE), and PaO2:FiO2 (F). CONCLUSIONS: We developed two models to estimate the breathing effort of patients on high-flow oxygen therapy. Our initial findings are promising and suggest that these models merit further evaluation.

8.
Crit Care ; 28(1): 177, 2024 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-38796447

RESUMEN

The use of transpulmonary pressure monitoring based on measurement of esophageal pressure has contributed importantly to the personalization of mechanical ventilation based on respiratory pathophysiology in critically ill patients. However, esophageal pressure monitoring is still underused in the clinical practice. This technique allows partitioning of the respiratory mechanics between the lungs and the chest wall, provides information on lung recruitment and risk of barotrauma, and helps titrating mechanical ventilation settings in patients with respiratory failure. In assisted ventilation modes and during non-invasive respiratory support, esophageal pressure monitoring provides important information on the inspiratory effort and work of breathing. Nonetheless, several controversies persist on technical aspects, interpretation and clinical decision-making based on values derived from this monitoring technique. The aim of this review is to summarize the physiological bases of esophageal pressure monitoring, discussing the pros and cons of its clinical applications and different interpretations in critically ill patients undergoing invasive and non-invasive respiratory support.


Asunto(s)
Enfermedad Crítica , Humanos , Enfermedad Crítica/terapia , Monitoreo Fisiológico/métodos , Respiración Artificial/métodos , Mecánica Respiratoria/fisiología
9.
Physiol Meas ; 45(5)2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38749433

RESUMEN

Objective.Intra-esophageal pressure (Pes) measurement is the recommended gold standard to quantify respiratory effort during sleep, but used to limited extent in clinical practice due to multiple practical drawbacks. Respiratory inductance plethysmography belts (RIP) in conjunction with oronasal airflow are the accepted substitute in polysomnographic systems (PSG) thanks to a better usability, although they are partial views on tidal volume and flow rather than true respiratory effort and are often used without calibration. In their place, the pressure variations measured non-invasively at the suprasternal notch (SSP) may provide a better measure of effort. However, this type of sensor has been validated only for respiratory events in the context of obstructive sleep apnea syndrome (OSA). We aim to provide an extensive verification of the suprasternal pressure signal against RIP belts and Pes, covering both normal breathing and respiratory events.Approach.We simultaneously acquired suprasternal (207) and esophageal pressure (20) signals along with RIP belts during a clinical PSG of 207 participants. In each signal, we detected breaths with a custom algorithm, and evaluated the SSP in terms of detection quality, breathing rate estimation, and similarity of breathing patterns against RIP and Pes. Additionally, we examined how the SSP signal may diverge from RIP and Pes in presence of respiratory events scored by a sleep technician.Main results.The SSP signal proved to be a reliable substitute for both esophageal pressure (Pes) and respiratory inductance plethysmography (RIP) in terms of breath detection, with sensitivity and positive predictive value exceeding 75%, and low error in breathing rate estimation. The SSP was also consistent with Pes (correlation of 0.72, similarity 80.8%) in patterns of increasing pressure amplitude that are common in OSA.Significance.This work provides a quantitative analysis of suprasternal pressure sensors for respiratory effort measurements.


Asunto(s)
Presión , Sueño , Humanos , Masculino , Sueño/fisiología , Femenino , Adulto , Pletismografía , Procesamiento de Señales Asistido por Computador , Respiración , Esternón/fisiología , Persona de Mediana Edad , Polisomnografía , Adulto Joven
10.
Sci Rep ; 14(1): 9771, 2024 04 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684823

RESUMEN

Transpulmonary pressure can be estimated using esophageal balloon (EB) catheters, which come in a variety of manufacturing configurations. We assessed the performance of novel polyurethane EB designs, Aspisafe NG and NG+, against existing alternatives. We created a biomechanical model of the chest cavity using a plastic chamber and an ex-vivo porcine esophagus. The chamber was pressurized (- 20 and + 20 cmH2O) to simulate pleural pressures. We conducted tests with various EB inflation volumes and measured transesophageal pressure (TEP). TEP measurement was defined as accurate when the difference between pressure within the EB and chamber was 0 ± 1 cmH2O. We computed the minimal (Vaccuracy-min) and maximal (Vaccuracy-max) EB inflation volumes of accuracy. Inflation volumes were further validated using a surrogate method derived by the clinically validated positive pressure occlusion test (PPOT). When the esophageal balloons were filled with inflation volumes within the range provided by the manufacturers, the accuracy of TEP measurements was marginal. Our tests found median Vaccuracy-min across EB of 0.00-0.50 mL (p = 0.130), whereas Vaccuracy-max ranged 0.50-2.25 mL (p = 0.002). Post PPOT validation, median TEP was - 0.4 cmH2O (- 1.5 to 0.3) (p < 0.001 among catheters). The Aspisafe NG and NG+ were accurate in 81.7% and 77.8% of the measurements, respectively. We characterized two new EBs, which demonstrated good benchtop accuracy in TEP measurements. However, accuracy was notably influenced by the precise selection of EB inflation volumes.


Asunto(s)
Catéteres , Esófago , Presión , Cavidad Torácica , Animales , Esófago/fisiología , Porcinos , Fenómenos Biomecánicos , Poliuretanos/química , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación
11.
J Appl Physiol (1985) ; 136(6): 1418-1428, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38602001

RESUMEN

Breathing effort is important to quantify to understand mechanisms underlying central and obstructive sleep apnea, respiratory-related arousals, and the timing and effectiveness of invasive or noninvasive mechanically assisted ventilation. Current quantitative methods to evaluate breathing effort rely on inspiratory esophageal or epiglottic pressure swings or changes in diaphragm electromyographic (EMG) activity, where units are problematic to interpret and compare between individuals and to measured ventilation. This paper derives a novel method to quantify breathing effort in units directly comparable with measured ventilation by applying respiratory mechanics first principles to convert continuous transpulmonary pressure measurements into "attempted" airflow expected to have arisen without upper airway obstruction. The method was evaluated using data from 11 subjects undergoing overnight polysomnography, including six patients with obesity with severe obstructive sleep apnea (OSA), including one who also had frequent central events, and five healthy-weight controls. Classic respiratory mechanics showed excellent fits of airflow and volume to transpulmonary pressures during wake periods of stable unobstructed breathing (means ± SD, r2 = 0.94 ± 0.03), with significantly higher respiratory system resistance in patients compared with healthy controls (11.2 ± 3.3 vs. 7.1 ± 1.9 cmH2O·L-1·s, P = 0.032). Subsequent estimates of attempted airflow from transpulmonary pressure changes clearly highlighted periods of acute and prolonged upper airway obstruction, including within the first few breaths following sleep onset in patients with OSA. This novel technique provides unique quantitative insights into the complex and dynamically changing interrelationships between breathing effort and achieved airflow during periods of obstructed breathing in sleep.NEW & NOTEWORTHY Ineffective breathing efforts with snoring and obstructive sleep apnea (OSA) are challenging to quantify. Measurements of esophageal or epiglottic pressure swings and diaphragm electromyography are useful, but units are problematic to interpret and compare between individuals and to measured ventilation. This paper derives a novel method that uses esophageal pressure and respiratory mechanics first principles to quantify breathing effort as "attempted" flow and volume in units directly comparable with measured airflow, volume, and ventilation.


Asunto(s)
Esófago , Polisomnografía , Mecánica Respiratoria , Apnea Obstructiva del Sueño , Humanos , Mecánica Respiratoria/fisiología , Masculino , Femenino , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/diagnóstico , Persona de Mediana Edad , Adulto , Polisomnografía/métodos , Esófago/fisiopatología , Esófago/fisiología , Presión , Respiración , Trabajo Respiratorio/fisiología
12.
Pulm Circ ; 14(1): e12348, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38449519

RESUMEN

We analyzed the effect of respiratory swings on interpreting intravascular pulmonary vascular pressures (PVPs) in chronic obstructive pulmonary disease (COPD) and interstitial lung disease (ILD) candidates for lung transplantation (LTx) and the role of the alterations in pulmonary function tests on the dynamic respiratory variations. Twenty-eight consecutive patients were included. All patients underwent a complete hemodynamic study (right atrial, mean pulmonary arterial, and pulmonary arterial occlusion pressures [RAP, mPAP, and PAOP]-) and pulmonary function testing (force vital capacity [FVC], forced expiratory volume in the first second [FEV1], and residual volume [RV]). A subgroup of 10 patients underwent simultaneous esophageal pressure (PES). All hemodynamic parameters and PES were collected during apnea after an unforced expiration (ee) and during spontaneous breathing averaging five respiratory cycles (mrc). The respiratory swing (osc) was estimated as the difference between maximum-minimum values of pressures during the respiratory cycle. Intravascular RAPee, mPAPee, and PAOPee were higher than mrc values (p < 0.05), leading to 11% of pulmonary hypertension (PH) misdiagnosis and 37% of postcapillary PH misclassification. PAOPosc of COPD was higher than ILD patients and RAPosc (p < 0.05). Only PAOPosc correlated with FVC, FEV1, and RV (p < 0.05). ILD PESmrc was lower than COPD (p < 0.05), and it was associated with a significantly higher transmural than intravascular RAPmrc, mPAPmrc, and PAOPmrc. PESmrc was significantly correlated with FVC. Transmural mPAPmrc and PAOPmrc readings determined around 20% of reclassification of the patients compared to ee measurements. Candidates for LTx showed large respiratory swings in PVP, which were correlated with pulmonary function alterations. mrc PVP would be more closely approximated to the true transmural PVP leading to PH reclassification. Adjusting PVP for PES should be considered in COPD and ILD candidates of LTx with severe alterations in pulmonary functional tests and suspicion of a PESmrc far from 0. PES respiratory swings could be different in ILD to COPD patients.

13.
J Emerg Med ; 66(4): e470-e476, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38461134

RESUMEN

BACKGROUND: Tracheal intubation is the gold standard for airway management in emergency medicine, but more difficult to apply for inexperienced individuals than laryngeal mask airway (LMA). OBJECTIVE: The aim of our study was to investigate if inexperienced individuals are able to secure the airway with the help of LMA after a short introduction. A second aim was to evaluate Thiel-fixed specimens against unfixed ones. METHODS: In a body donor model, LMA application was evaluated between medical students without previous airway experience and anesthesiologists by comparing the sealing of the larynx using a water column applied to the esophagus. RESULTS: LMAs were successfully applied in 46 out of 55 (83.6%) attempts by medical students and in 30 out of 39 (76.9%) attempts by anesthesiologists. Among medical students, 14.1% of all LMA applications were primarily leaky, compared with 18.8% in anesthesiologists. Esophageal sealing was better in Thiel-fixed specimens (leakage 10.9%) compared with unfixed specimens (leakage 22.9%). Our data showed no significant difference between anesthesiologists and medical students in terms of sealing of LMA. Therefore, we conclude that medical students without previous airway experience can quickly learn to apply LMA sufficiently and thus, achieve aspiration protection similar to anesthesiologists. CONCLUSION: Medical students without previous airway experience can successfully insert LMAs after a short introduction. Thiel-fixed specimens are suitable for studies as well as for training in LMA application.


Asunto(s)
Máscaras Laríngeas , Humanos , Anestesiólogos , Intubación Intratraqueal , Manejo de la Vía Aérea , Esófago
14.
J Thorac Dis ; 16(2): 979-988, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38505046

RESUMEN

Background: Esophageal pressure (Pes) has been used as a surrogate of pleural pressure (Ppl) to titrate positive end-expiratory pressure (PEEP) in acute respiratory distress syndrome (ARDS) patients. The relationship between Pes and PEEP remains undetermined. Methods: A gastric tube with a balloon catheter was inserted to monitor Pes in moderate to severe ARDS patients who underwent invasive mechanical ventilation. To assess the end-expiratory Pes response (ΔPes) to PEEP changes (ΔPEEP), the PEEP level was decreased and increased subsequently (with an average change of 3 cmH2O). The patients underwent the following two series of PEEP adjustment: (I) from PEEP-3 cmH2O to PEEPbaseline; and (II) from PEEPbaseline to PEEP+3 cmH2O. The patients were classified as "PEEP-dependent type" if they had ΔPes ≥30% ΔPEEP and were otherwise classified as "PEEP-independent type" (ΔPes <30% ΔPEEP in any series). Results: In total, 54 series of PEEP adjustments were performed in 18 ARDS patients. Of these patients, 12 were classified as PEEP-dependent type, and six were classified as PEEP-independent type. During the PEEP adjustment, end-expiratory Pes changed significantly in the PEEP-dependent patients, who had a Pes of 10.8 (7.9, 12.3), 12.5 (10.5, 14.9), and 14.5 (13.1, 18.3) cmH2O at PEEP-3 cmH2O, PEEPbaseline, and PEEP+3 cmH2O, respectively (median and quartiles; P<0.0001), while end-expiratory transpulmonary pressure (PL) was maintained at an optimal range [-0.1 (-0.7, 0.4), 0.1 (-0.6, 0.5), and 0.3 (-0.3, 0.7) cmH2O, respectively]. In the PEEP-independent patients, the Pes remained unchanged, with a Pes of 15.4 (11.4, 17.8), 15.5 (11.6, 17.8), and 15.4 (11.7, 18.30) cmH2O at each of the three PEEP levels, respectively. Meanwhile, end-expiratory PL significantly improved [from -5.5 (-8.5, -3.4) at PEEP-3 cmH2O to -2.5 (-5.0, -1.6) at PEEPbaseline to -0.5 (-1.8, 0.3) at PEEP+3 cmH2O; P<0.01]. Conclusions: Two types of Pes phenotypes were identified according to the ΔPes to ΔPEEP. The underlying mechanisms and implications for clinical practice require further exploration.

15.
J Clin Monit Comput ; 38(4): 847-858, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38512359

RESUMEN

Transpulmonary pressure (PL) calculation requires esophageal pressure (PES) as a surrogate of pleural pressure (Ppl), but its calibration is a cumbersome technique. Central venous pressure (CVP) swings may reflect tidal variations in Ppl and could be used instead of PES, but the interpretation of CVP waveforms could be difficult due to superposition of heartbeat-induced pressure changes. Thus, we developed a digital filter able to remove the cardiac noise to obtain a filtered CVP (f-CVP). The aim of the study was to evaluate the accuracy of CVP and filtered CVP swings (ΔCVP and Δf-CVP, respectively) in estimating esophageal respiratory swings (ΔPES) and compare PL calculated with CVP, f-CVP and PES; then we tested the diagnostic accuracy of the f-CVP method to identify unsafe high PL levels, defined as PL>10 cmH2O. Twenty patients with acute respiratory failure (defined as PaO2/FiO2 ratio below 200 mmHg) treated with invasive mechanical ventilation and monitored with an esophageal balloon and central venous catheter were enrolled prospectively. For each patient a recording session at baseline was performed, repeated if a modification in ventilatory settings occurred. PES, CVP and airway pressure during an end-inspiratory and -expiratory pause were simultaneously recorded; CVP, f-CVP and PES waveforms were analyzed off-line and used to calculate transpulmonary pressure (PLCVP, PLf-CVP, PLPES, respectively). Δf-CVP correlated better than ΔCVP with ΔPES (r = 0.8, p = 0.001 vs. r = 0.08, p = 0.73), with a lower bias in Bland Altman analysis in favor of PLf-CVP (mean bias - 0.16, Limits of Agreement (LoA) -1.31, 0.98 cmH2O vs. mean bias - 0.79, LoA - 3.14, 1.55 cmH2O). Both PLf-CVP and PLCVP correlated well with PLPES (r = 0.98, p < 0.001 vs. r = 0.94, p < 0.001), again with a lower bias in Bland Altman analysis in favor of PLf-CVP (0.15, LoA - 0.95, 1.26 cmH2O vs. 0.80, LoA - 1.51, 3.12, cmH2O). PLf-CVP discriminated high PL value with an area under the receiver operating characteristic curve 0.99 (standard deviation, SD, 0.02) (AUC difference = 0.01 [-0.024; 0.05], p = 0.48). In mechanically ventilated patients with acute respiratory failure, the digital filtered CVP estimated ΔPES and PL obtained from digital filtered CVP represented a reliable value of standard PL measured with the esophageal method and could identify patients with non-protective ventilation settings.


Asunto(s)
Presión Venosa Central , Esófago , Respiración Artificial , Humanos , Respiración Artificial/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Presión , Insuficiencia Respiratoria/terapia , Insuficiencia Respiratoria/fisiopatología , Reproducibilidad de los Resultados , Anciano de 80 o más Años , Pleura/fisiopatología , Algoritmos , Volumen de Ventilación Pulmonar
17.
Ann Intensive Care ; 14(1): 32, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38407643

RESUMEN

BACKGROUND: Characterizing patient-ventilator interaction in critically ill patients is time-consuming and requires trained staff to evaluate the behavior of the ventilated patient. METHODS: In this study, we recorded surface electromyography ([Formula: see text]) signals from the diaphragm and intercostal muscles and esophageal pressure ([Formula: see text]) in mechanically ventilated patients with ARDS. The sEMG recordings were preprocessed, and two different algorithms (triangle algorithm and adaptive thresholding algorithm) were used to automatically detect inspiratory patient effort. Based on the detected inspirations, major asynchronies (ineffective, auto-, and double triggers and double efforts), delayed and synchronous triggers were computationally classified. Reverse triggers were not considered in this study. Subsequently, asynchrony indices were calculated. For the validation of detected efforts, two experts manually annotated inspiratory patient activity in [Formula: see text], blinded toward each other, the [Formula: see text] signals, and the algorithmic results. We also classified patient-ventilator interaction and calculated asynchrony indices with manually detected inspirations in [Formula: see text] as a reference for automated asynchrony classification and asynchrony index calculation. RESULTS: Spontaneous breathing activity was recognized in 22 out of the 36 patients included in the study. Evaluation of the accuracy of the algorithms using 3057 inspiratory efforts in [Formula: see text] demonstrated reliable detection performance for both methods. Across all datasets, we found a high sensitivity (triangle algorithm/adaptive thresholding algorithm: 0.93/0.97) and a high positive predictive value (0.94/0.89) against expert annotations in [Formula: see text]. The average delay of automatically detected inspiratory onset to the [Formula: see text] reference was [Formula: see text]79 ms/29 ms for the two algorithms. Our findings also indicate that automatic asynchrony index prediction is reliable. For both algorithms, we found the same deviation of [Formula: see text] to the [Formula: see text]-based reference. CONCLUSIONS: Our study demonstrates the feasibility of automating the quantification of patient-ventilator asynchrony in critically ill patients using noninvasive sEMG. This may facilitate more frequent diagnosis of asynchrony and support improving patient-ventilator interaction.

18.
J Clin Monit Comput ; 38(3): 701-714, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38310590

RESUMEN

Esophageal pressure (Peso) is one of the most common and minimally invasive methods used to assess the respiratory and lung mechanics in patients receiving mechanical ventilation. However, the Peso measurement is contaminated by cardiogenic oscillations (CGOs), which cannot be easily eliminated in real-time. The field of study dealing with the elimination of CGO from Peso signals is still in the early stages of its development. In this study, we present an adaptive filtering-based method by constructing a reference signal based on the heart rate and sine function to remove CGOs in real-time. The proposed technique is tested using clinical data acquired from 20 patients admitted to the intensive care unit. Lung compliance ( QUOTE ) and esophageal pressure swings (△Pes) are used to evaluate the performance and efficiency of the proposed technique. The CGO can be efficiently suppressed when the constructional reference signal contains the fundamental, and second and third harmonic frequencies of the heart rate signal. The analysis of the data of 8 patients with controlled mechanical ventilation reveals that the standard deviation/mean of the QUOTE is reduced by 28.4-79.2% without changing the QUOTE and the △Pes measurement is more accurate, with the use of our proposed technique. The proposed technique can effectively eliminate the CGOs from the measured Peso signals in real-time without requiring additional equipment to collect the reference signal.


Asunto(s)
Algoritmos , Esófago , Frecuencia Cardíaca , Respiración Artificial , Procesamiento de Señales Asistido por Computador , Humanos , Frecuencia Cardíaca/fisiología , Esófago/fisiología , Respiración Artificial/métodos , Masculino , Presión , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Femenino , Persona de Mediana Edad , Unidades de Cuidados Intensivos , Rendimiento Pulmonar , Anciano , Mecánica Respiratoria , Relación Señal-Ruido , Reproducibilidad de los Resultados
19.
Respir Care ; 69(3): 325-332, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38195144

RESUMEN

BACKGROUND: Accuracy of esophageal pressure measured by an air-filled esophageal balloon catheter is dependent on balloon filling volume. However, this has been understudied in mechanically ventilated children. We sought to study the optimal filling volume in children receiving ventilation by using previously reported calibration methods. Secondary objectives included to examine the difference in pressure measurements at individualized optimal filling volume versus a standardized inflation volume and to study if a static hold during calibration is required to identify the optimal filling volume. METHODS: An incremental inflation calibration procedure was performed in children receiving ventilation, <18 y, instrumented with commercially available catheters (6 or 8 French) who were not breathing spontaneously. The balloon was manually inflated by 0.2 to 1.6 mL (6 French) or 2.6 mL (8 French). Esophageal pressure (Pes) and airway pressure tracings were recorded during the procedure. Data were analyzed offline by using 2 methods: visual determination of filling range with the calculation of the highest difference between expiratory and inspiratory Pes and determination of a correctly filled balloon by calculating the esophageal elastance. RESULTS: We enrolled 40 subjects with median (interquartile range [IQR]) age 6.8 (2-25) months. The optimal filling volume ranged from 0.2 to 1.2 mL (median [IQR] 0.6 [0.2-1.0] mL) in the subjects with a 6 French catheter and 0.2-2.0 mL (median [IQR] 0.7 [0.5-1.2] mL) for 8 French catheters. Inflating the balloon with 0.6 mL (median computed from the whole cohort) gave an absolute difference in transpulmonary pressure that ranged from -4 to 7 cm H2O compared with the personalized volume. Pes calculated over 5 consecutives breaths differed with a maximum of 1 cm H2O compared to Pes calculated during a single inspiratory hold. The esophageal elastance was correlated with weight, age, and sex. CONCLUSIONS: The optimal balloon inflation volume was highly variable, which indicated the need for an individual calibration procedure. Pes was not overestimated when an inspiratory hold was not applied.


Asunto(s)
Respiración Artificial , Mecánica Respiratoria , Niño , Humanos , Respiración Artificial/métodos , Presión , Catéteres , Pruebas de Función Respiratoria/métodos
20.
Ann Intensive Care ; 14(1): 1, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38180544

RESUMEN

BACKGROUND: Various Positive End-Expiratory Pressure (PEEP) titration strategies have been proposed to optimize ventilation in patients with acute respiratory distress syndrome (ARDS). We aimed to compare PEEP titration strategies based on electrical impedance tomography (EIT) to methods derived from respiratory system mechanics with or without esophageal pressure measurements, in terms of PEEP levels and association with recruitability. METHODS: Nineteen patients with ARDS were enrolled. Recruitability was assessed by the estimated Recruitment-to-Inflation ratio (R/Iest) between PEEP 15 and 5 cmH2O. Then, a decremental PEEP trial from PEEP 20 to 5 cmH2O was performed. PEEP levels determined by the following strategies were studied: (1) plateau pressure 28-30 cmH2O (Express), (2) minimal positive expiratory transpulmonary pressure (Positive PLe), (3) center of ventilation closest to 0.5 (CoV) and (4) intersection of the EIT-based overdistension and lung collapse curves (Crossing Point). In addition, the PEEP levels determined by the Crossing Point strategy were assessed using different PEEP ranges during the decremental PEEP trial. RESULTS: Express and CoV strategies led to higher PEEP levels than the Positive PLe and Crossing Point ones (17 [14-17], 20 [17-20], 8 [5-11], 10 [8-11] respectively, p < 0.001). For each strategy, there was no significant association between the optimal PEEP level and R/Iest (Crossing Point: r2 = 0.073, p = 0.263; CoV: r2 < 0.001, p = 0.941; Express: r2 < 0.001, p = 0.920; Positive PLe: r2 = 0.037, p = 0.461). The PEEP level obtained with the Crossing Point strategy was impacted by the PEEP range used during the decremental PEEP trial. CONCLUSIONS: CoV and Express strategies led to higher PEEP levels than the Crossing Point and Positive PLe strategies. Optimal PEEP levels proposed by these four methods were not associated with recruitability. Recruitability should be specifically assessed in ARDS patients to optimize PEEP titration.

SELECCIÓN DE REFERENCIAS