1.
J. oral res. (Impresa) ; 11(6): 1-10, nov. 3, 2022. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1437657

RESUMEN

Aim: To assess the effect of different mechanical surface treatments on flexural strength of repaired denture base. Material and Methods: Sixty bar-shaped specimens of heat-polymerized acrylic resin were fabricated, and divided into six groups (n=10). All specimens, except the positive control group (group PC), were sectioned into halves to create a 1-mm clearance. A negative control group with no surface treatment (group NC) was also considered. Other groups underwent different surface treatments: group Laser; treated with erbium: yttrium-aluminum-garnet (Er:YAG) laser, group APA; airborne-particle abrasion (APA), group APA plus Laser; a combination of laser and APA, and group Bur; bur grinding. After measuring surface roughness (Ra) with a profilometer, all sectioned specimens were repaired by auto-polymerizing acrylic resin, and thermocycled afterward. Three-point bending test was performed by a universal testing machine. Data were statistically analyzed (α=0.05). Results: The mean surface roughness of all experimental groups were significantly higher than that of group NC (p<0.05). The mean flexural strength of all groups was significantly lower than that of group PC (p<0.05). Group B had significantly higher flexural strength than the other surface-treated groups (p<0.05). Group Laser had significantly higher flexural strength than groups APA (p=0.043) and APA plus Laser (p=0.023). No significant difference was found between groups APA and APA plus Laser (p=0.684). Conclusion: All surface treatments increased the surface roughness and flexural strength compared with the untreated group. The highest flexural strength was observed in specimens treated by bur grinding and then laser, however, it was still significantly lower than intact specimens.


Objetivo: Evaluar el efecto de diferentes tratamientos superficiales mecánicos sobre la resistencia a la flexión de la base de la prótesis reparada. Material y Métodos: Se fabricaron sesenta especímenes en forma de barra de resina acrílica termo-polimerizada y se dividieron en seis grupos (n=10). Todas las muestras, excepto el grupo de control positivo (grupo PC), se seccionaron en mitades para crear un espacio libre de 1 mm. También se consideró un grupo de control negativo sin tratamiento superficial (grupo NC). Otros grupos se sometieron a diferentes tratamientos superficiales: grupo Láser; tratados con láser de erbio: itrio-aluminio-granate (Er:YAG), grupo APA; abrasión por partículas en el aire (APA), grupo APA más láser; una combinación de láser y APA, y grupo Bur; molienda de fresas. Después de medir la rugosidad de la superficie (Ra) con un perfilómetro, todas las muestras seccionadas se repararon con resina acrílica de autopolimerización y se sometieron a termociclado. La prueba de flexión de tres puntos se realizó con una máquina de prueba universal. Los datos se analizaron estadísticamente (α=0,05). Resultados: La rugosidad superficial media de todos los grupos experimentales fue significativamente mayor que la del grupo NC (p<0,05). La resistencia media a la flexión de todos los grupos fue significativamente menor que la del grupo PC (p<0,05). El grupo B tenía una resistencia a la flexión significativamente mayor que los otros grupos tratados en la superficie (p<0,05). El grupo Láser tuvo una resistencia a la flexión significativamente mayor que los grupos APA (p=0,043) y APA más Láser (p=0,023). No se encontró diferencia significativa entre los grupos APA y APA más Láser (p=0,684). Conclusión: Todos los tratamientos superficiales aumentan la rugosidad de la superficie y la resistencia a la flexión en comparación con el grupo sin tratar. La resistencia a la flexión más alta se observó en las muestras tratadas con fresado y luego con láser; sin embargo, aún era significativamente más baja que las muestras intactas.


Asunto(s)
Humanos , Resinas Acrílicas/química , Reparación de la Dentadura , Polimetil Metacrilato/química , Materiales Dentales/química , Bases para Dentadura , Láseres de Estado Sólido , Metacrilatos/química
2.
Rev. cuba. estomatol ; 57(3): e3142, jul.-set. 2020. graf
Artículo en Español | LILACS, CUMED | ID: biblio-1126529

RESUMEN

RESUMEN Introducción: Al realizar una intervención quirúrgica, el instrumento de corte utilizado cobra especial importancia, pues el mismo está vinculado a los signos y síntomas intra- y posoperatorios y al tiempo de reparación de los tejidos. En respuesta a esto, con el tiempo se han propuesto nuevos instrumentos, particularmente la tecnología láser ha venido sufriendo un avance rápido y significativo y en la actualidad se utiliza para un sinnúmero de tratamientos odontológicos. Al láser se le han atribuido diferentes ventajas en la cirugía estética periodontal: desde facilitar el proceso de hemostasia, hasta la estimulación del proceso de reparación tisular. Sin embargo, es pertinente realizar estudios que demuestren a nivel histológico los cambios que generan en la mucosa oral y obtener información que permita conocer de qué manera influye en el proceso de reparación del tejido. Objetivo: Describir los hallazgos histológicos asociados al corte con láser de Er, Cr: YSGG de 2780 nm en muestras de encía obtenidas mediante gingivectomía. Presentación del caso: Paciente femenina, de 21 años, sistémicamente sana. Asistió a la consulta por presentar por inconformidad estética al sonreír. Se diagnosticó con exposición de banda de encía queratinizada mayor que 4 mm. Como parte del plan de tratamiento se indicó gingivectomía con láser de Er, Cr: YSGG (2780 nm) (Waterlase®, BIOLASE®), el procedimiento se realizó solo bajo anestesia tópica. Se tomaron muestras histológicas de tejido gingival para análisis histológico. Conclusiones: El láser Er, Cr: YSGG (2780 nm) preservó la morfología de los fibroblastos después del corte, no hubo evidencia de carbonización, ni profundización de la lesión térmica en el tejido. Este instrumento fue una herramienta de gran utilidad para la ejecución del tratamiento en este caso. Tuvo ventajas importantes como la ausencia de dolor posoperatorio, buena hemostasia y la reparación epitelial casi completa en tan solo 4 días(AU)


ABSTRACT Introduction: When performing a surgical intervention, the cutting instrument used is especially important, since it is associated with intraoperative and postoperative signs and symptoms and to the time of tissue repair. In response to this, new instruments have been proposed over time, particularly laser technology has been undergoing rapid and significant advancement and is currently used for countless dental treatments. Laser has been attributed different advantages in periodontal cosmetic surgery: from facilitating the hemostasis process, to stimulating the tissue repair process. However, it is pertinent to carry out studies that prove, at histological level, the changes in the oral mucosa and obtain information that allows us to know how it influences the tissue repair process. Objective: To describe the histological findings associated with the Er, Cr: YSGG (2780 nm) laser cut in gum samples obtained by gingivectomy. Case presentation: Female patient, 21 years old, systemically healthy. She attended the consultation for presenting aesthetic dissatisfaction when smiling. She was diagnosed with exposure of keratinized gum band greater than 4 mm. As part of the treatment plan, Er, Cr: YSGG (Waterlase®, BIOLASE®, 2780 nm) laser gingivectomy was indicated. The procedure was performed only under topical anesthesia. Histological samples of gingival tissue were taken for histological analysis. Conclusions: The Er, Cr: YSGG (2780 nm) laser preserved the morphology of the fibroblasts after the cut. There was no evidence of carbonization or deepening of the thermal injury in the tissue. In this case, this instrument was a very useful tool for the performance of the treatment. It had important advantages, such as the absence of postoperative pain, good hemostasis, and almost complete epithelial repair in just four days(AU)


Asunto(s)
Humanos , Femenino , Adulto Joven , Gingivectomía/efectos adversos , Estética Dental , Láseres de Estado Sólido/uso terapéutico
3.
J. oral res. (Impresa) ; 8(2): 131-139, abr. 30, 2019. tab, ilus, graf
Artículo en Inglés | LILACS | ID: biblio-1145313

RESUMEN

Purpose: De-bonding strength of ceramic veneers by laser use needs to be evaluated in detail. The aim of this study, is to determine the contribution of ceramic thickness and cementing agents to the de-bonding strength of ceramic veneers using Er,Cr:YSGG laser. Methods: A total of 120 maxillary central incisors specimens were randomly divided into twelve groups on the basis of disc thickness, cementing agent, and Er,Cr:YSGG laser use. Under laboratory conditions, 120 IPS Empress II system discs 0.5mm, 1mm, and 2mm in thickness were applied to the tooth surfaces, for laser use. An Er,Cr:YSGG laser system was applied to the central surface of the IPS Empress II discs on specimens in all laser groups (Groups 1,3,5,7,9,11). Then the shear bond strength (SBS) for all specimens were tested with a testing machine at a speed of 0.5mm/min. The SBS values were considered as the de-bonding strength. Results: The mean de-bonding strength values for Groups 9 and 11 (0,5 mm disc thickness + laser application) have the lowest median load (0.000 N), while Group 4 (2mm disc thickness + no laser) has the highest median load (573.885 N). The de-bonding strengths of all the groups without laser application were higher than those of all groups with laser use. When laser is applied, the mean de-bonding strength decreases with decreasing disc thickness, and it reaches zero at 0.5mm thickness of discs cemented by self- or total-etch adhesives. Conclusions: The de-bonding strength decreases with laser use, and decreasing disc thickness. In the absence of laser, the mean de-bonding values of discs cemented by a total etch adhesive system are always higher than those of discs cemented with a self-etch adhesive system. Without any extra load, all 0.5mm thick discs were dislodged from teeth while applying or testing the laser.


Propósito: La resistencia de desunión de las carillas de cerámica mediante el uso del láser debe evaluarse en detalle. El objetivo de este estudio es determinar la contribución del espesor de la cerámica y los agentes de cementación a la resistencia de desunión de las carillas de cerámica utilizando el láser Er, Cr: YSGG. Métodos: Un total de 120 incisivos centrales maxilares se dividieron al azar en doce grupos según el grosor del disco, el agente de cementación y el uso del láser Er, Cr: YSGG. En condiciones de laboratorio, se aplicaron en las superficies de los dientes 120 discos del sistema IPS Empress II de 0,5mm, 1mm y 2mm de grosor, para uso con láser. Se aplicó un sistema láser Er, Cr: YSGG a la superficie central de los discos IPS Empress II en muestras de todos los grupos de láser (Grupos 1,3,5,7,9,11). Luego, la resistencia de la unión al cizallamiento (SBS) para todas las muestras se probó con una máquina de prueba a una velocidad de 0.5mm/min. Los valores de SBS se consideraron como la fuerza de desunión. Resultados: Los valores medios de resistencia de desunión para los Grupos 9 y 11 (espesor de disco de 0,5mm + aplicación de láser) demostró la carga media más baja (0,000 N), mientras que el Grupo 4 (espesor de disco de 2 mm + sin láser) tuvo la carga media más alta (573.885 N). Las fuerzas de desunión de todos los grupos sin aplicación de láser fueron superiores a las de todos los grupos con uso de láser. Cuando se aplica el láser, la fuerza media de desunión disminuye al disminuir el grosor del disco, y llega a cero con el grosor de 0,5mm de los discos cementados, para ambos adhesivos de grabado. Conclusiones: la fuerza de desunión disminuye con el uso del láser y disminuye con el grosor del disco. En ausencia de láser, los valores medios de desunión de los discos cementados con un sistema de adhesivo de grabado total son siempre más altos que los de los discos cementados con un sistema de adhesivo de autograbado. Sin ninguna carga adicional, todos los discos de 0,5mm de grosor se desprendieron de los dientes al aplicar el láser.


Asunto(s)
Humanos , Cerámica/uso terapéutico , Recubrimiento Dental Adhesivo , Resistencia al Corte , Láseres de Estado Sólido/uso terapéutico , Esmalte Dental/efectos de la radiación , Materiales Dentales/química , Coronas con Frente Estético
4.
Dent Med Probl ; 55(3): 255-259, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30328302

RESUMEN

BACKGROUND: It has been reported that lasers can increase resistance to enamel acids, and when it is associated with fluoride, both are reported to work in synergy, achieving a reduction of the solubility of enamel. Currently, other remineralizing agents have been shown to effectively inhibit enamel demineralization. OBJECTIVES: The aim of the study was to evaluate acid resistance in the occlusal surface of permanent teeth, treated with remineralizing agents, erbium-doped yttrium aluminum garnet (Er:YAG) laser and combined treatments. MATERIAL AND METHODS: Eighty samples of enamel were randomly assigned to 8 groups (n = 10): a control group, and groups treated with sodium fluoride (NaF), casein phosphopeptide-amorphous calcium phosphate with NaF (CPP-ACPF), hydroxyapatite-NaF-xylitol (HA-NaF-X), Er:YAG laser (L), L+NaF, L+CPP-ACPF, and L+HA-NaF-X. The samples were placed in an acid solution and the released calcium (Ca) was quantified by atomic absorption spectrometry. RESULTS: In the groups treated with NaF and L+NaF, a lower loss of Ca was observed - 15.27 ±5.17 mg/L and 15.20 ±3.85 mg/L, respectively - compared to the control group, which had the highest Ca loss: 21.93 ±13.24 mg/L. CONCLUSIONS: Although the combination of Er:YAG laser plus NaF and the single application of NaF showed values suggesting superior resistance to demineralization of dental enamel compared to all the other groups in the study, no statistically significant differences were found to support this assertion.


Asunto(s)
Ácidos/efectos adversos , Esmalte Dental/efectos de los fármacos , Esmalte Dental/efectos de la radiación , Láseres de Estado Sólido , Calcio/metabolismo , Cariostáticos/farmacología , Caseínas/farmacología , Esmalte Dental/metabolismo , Durapatita/farmacología , Humanos , Técnicas In Vitro , Distribución Aleatoria , Fluoruro de Sodio/farmacología , Espectrofotometría Atómica , Xilitol/farmacología
5.
Materials (Basel) ; 11(9)2018 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-30205464

RESUMEN

The effect of the substitution of Y3+ by Nd3+ on the structural and magnetic properties of neodymium-doped yttrium iron garnet, NdxY3-xFe5O12 with x in the range of 0⁻2.5, is presented. Oxide powders of Fe2O3, Nd2O3, and Y2O3 were mixed in a stoichiometric ratio and milled for 5 h using high-energy ball milling, before being uniaxially pressed at 900 MPa and annealed at 1373 K for 2 h to obtain NdxY3-xFe5O12 (0 ≤ x ≤ 2.5). It was found that the mechanical milling of oxides followed by annealing promotes the complete structural formation of the garnet structure. Additionally, the X-ray diffraction patterns confirm the complete introduction of Nd3+ into the garnet structure with a neodymium doping concentration (x) of 0⁻2.0, which causes a consistent increment in the lattice parameters with the Nd3+ content. When x is higher than 2.0, the yttrium orthoferrite is the predominant phase. Besides, the magnetic results reveal an increase in the Curie temperature (583 K) as the amount of Nd3+ increases, while there was enhanced saturation magnetization as well as modified remanence and coercivity with respect to non-doped YIG.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA