Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.436
Filtrar
1.
AME Case Rep ; 8: 70, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39091545

RESUMEN

Background: Type II endoleaks are common and embolization is often performed if treatment is necessary. Although transarterial embolization is common, other methods including trans-caval embolization are also utilized. Complications can occur and we report a case of infection that was challenging to diagnose and treat. There is no data regarding the risk of aortic stent graft infection after trans-caval embolization with n-butyl 2-cyanoacrylate (n-BCA) glue of a type II endoleak. Case Description: We report a rare case of infected, Gore Excluder infrarenal stent graft after transcaval embolization with coil and n-BCA glue to treat a type II endoleak in a 71-year-old male. The endoleak caused a rapid sac enlargement. The stent graft was placed 5 years earlier electively. Soon after the endoleak embolization, the patient experienced abdominal pain and malaise. There was an intense inflammatory reaction involving the aneurysm wall and the adjacent bowel mesentery. Our differential included normal inflammation after embolization vs. infection and this was difficult to distinguish. The infection was confirmed by positron emission tomography scan and tissue biopsy. The patient was deemed high-risk for surgery because of his extensive cardiac history, status post coronary bypass and tissue mitral valve replacement, congestive heart failure with residual left ventricular ejection fraction of 36%. He was optimized by correcting fluid status, administration of intravenous antibiotic, and nutrition consultation with dietary supplementation before surgery over the course of 2 weeks. The graft was explanted through a transabdominal approach, and the aorta was reconstructed with cryopreserved allograft. Interestingly, the small and large intestine with their mesentery were found to be plastered to the aneurysm sac. The post-operative course was unremarkable except for a transient acute kidney injury that resolved within 1 week. Follow-up computed tomography scan at 6 months showed widely patent bypass. Conclusions: Glue embolization induces inflammation promoting thrombus formation inside the aneurysm sac. With a transcaval approach to the sac, there is the risk of extravasation of glue outside the sac as well as contamination of the graft with instrumentation. Differentiating between inflammation and infection can be difficult, and tissue biopsy provided the most conclusive diagnosis. Risk minimization considerations include, pre-operative optimization, a transabdominal approach, ureteral stenting, and tissue buttressing of anastomosis.

2.
JPRAS Open ; 41: 166-172, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39040145

RESUMEN

Background: Abdominoplasty is a common surgical procedure in which excess abdominal skin and fat are reduced to improve body contouring. Fibrin sealant has been proposed to reduce postsurgical bleeding and exudation. In this study, we evaluated whether there was a significant statistical difference in surgical output between the use of fibrin glue and its nonuse in abdominoplasty surgery, specifically in reducing bleeding and exudation. Material and methods: A retrospective chart review of 68 postbariatric abdominoplasty patients (58 females, 10 males) was performed. We divided the patients into Group A (30 cases, 44%), in which we used fibrin sealant, and Group B (38 cases, 56%), in which we did not use fibrin glue. We calculated the total amount of liquid in suction drainages until the day of their removal. Statistical analysis included the independent t-test with a significance level of 0.05. Results: The average drainage output in Group A was 620.0 ± 375.0 mL, whereas in Group B, it was 500.0 ± 290.0 mL. Results indicate an insignificant correlation between the use of fibrin glue and the amount of liquid in the surgical drains (t = 1.52, p = 0.13). The result is not significant at p <.05 according to the independent t-test. Conclusion: The use of fibrin sealant surely has a high value in all surgical branches to reduce postoperative complications, but in our study, we did not find any advantages in its use for reducing surgical drain output in abdominoplasty patients.

3.
CVIR Endovasc ; 7(1): 58, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39066948

RESUMEN

Sinistral portal hypertension, also known as left-sided portal hypertension, is a rare cause of gastric variceal bleeding which occurs secondary to occlusion of the splenic vein. We present a case of venous occlusion and sinistral portal hypertension secondary to distal pancreatic cancer requiring treatment of gastric variceal bleeding. After failing conservative management, transvenous intervention was attempted, but a venous communication with the gastric varices was unable to be identified on multiple venograms. A percutaneous trans-splenic approach using a 21-G needle and ultrasound guidance was successful in directly accessing an intraparenchymal vein feeding the gastric varices, and glue embolization was performed directly through the access needle with excellent results.

4.
Front Cardiovasc Med ; 11: 1426961, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39027005

RESUMEN

Objective: This study aimed to evaluate the feasibility of a hybrid Glubran-supported single-Proglide technique for large bore femoral access closure during percutaneous access endovascular aneurysm repair (EVAR). Methods: A retrospective cohort study was performed for all percutaneous EVARs at our center from January 2023 to June 2023. All patients received the hybrid Glubran-supported single-Proglide technique involving a mixture of surgical glue and Lipiodol injection after single suture placement for femoral access closure. Technical success was defined as achieving complete hemostasis without a bailout strategy. Vascular complications and bleeding were defined by Valve Academic Research Consortium-3 (VARC-3) criteria. Vascular access changes and 30-day mortality were recorded. Results: The technique success rate for the entire study population was 100% (55 femoral access in 37 patients; median age: 72; 78% males). The mean sheath size was 20.4 ± 2.3F. The mean manual compression time was 3.5 ± 1.4 min, the mean hemostasis time was 9.0 ± 2.5 min, and the mean procedural time was 103.9 ± 34.7 min. One patient (1.6%) developed an access site infection and recovered conservatively. No VARC-3 vascular complications and access changes were observed. No 30-day mortality happened. Conclusions: The hybrid Glubran-supported single-Proglide technique is feasible for large bore access closure during EVAR and may be a viable alternative; however, larger prospective studies are required to confirm its efficacy.

5.
Endosc Ultrasound ; 13(1): 35-39, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38947113

RESUMEN

Background and Objectives: In portal hypertension, gastric varix-associated bleeding is known to have higher transfusion requirements, uncontrolled bleeding, rebleeding, intensive care unit requirements, and death. EUS-guided coil insertion is now an acceptable modality for endoscopic management in cases of gastric varices. With this study, we discuss our large single-center experience in the use of EUS for coil and glue injection in gastric varices. We also look into adverse events associated with and possibilities of using this modality as both primary prophylaxis and a rescue therapy. Methods: The study was conducted in a tertiary care center in India. A total of 86 patients were included in the study. The indication for EUS-guided coil and glue was divided into 3 clinical situations, namely, rebleed, rescue, and primary. The technical success and clinical success, that is, control of bleed in patients, were confirmed by absence of Doppler signal on EUS, endoscopic view, and stabilized hemoglobin with no need of blood product transfusion to maintain hemoglobin. Results: The mean Child-Turcotte-Pugh score and Model for End-Stage Liver Disease-Na score were 9.2 and 14.6, respectively. The mean size of the gastric varices was 18.9 mm. The mean number of coils used was 2.9, and the average quantity of glue required was 1.6 mL. The technical success was 100% across the patient group. Clinical success was seen in 90% of the patient group. Mean follow-up was seen for 175.2 days. Conclusions: EUS-guided coil and glue therapy has a role in different clinical settings, as primary therapy, rebleed, and rescue therapy. It has significant technical and clinical success. Its role in treatment algorithms needs to be further studied in prospective studies. It may offer a cost advantage in comparison to interventional radiology-led interventions.

6.
Int Ophthalmol ; 44(1): 297, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38951293

RESUMEN

BACKGROUND/OBJECTIVES: To evaluate the effect of topical cyclosporine A (CsA) 0.05% in patients with pterygium surgery using fibrin glue (FG). SUBJECTS/METHODS: Patients with primary nasal pterygium were retrospectically analyzed and categorized into two groups: Group 1 with 41 eyes from 38 patients as a control group and group 2 with 39 eyes from 36 patients who received topical CsA twice a day for 6 months. Patients were assessed for recurrence rate, tear film parameters, side effects, and complications at postoperative intervals of 1-7 days; 1st, 3rd, 6th and 12th months. The follow-up period was 1 year. RESULTS: The two groups were age (p = 0.934) and sex (p = 0.996) matched. CsA drop was discontinued in one patient due to burning sensation and conjunctival hyperemia after 1 week. There was no statistically significant difference between the mean preoperative and postoperative 1st year Schirmer I and tear break-up time (TBUT) values in group 1 (p = 0.136; p = 0.069). Although the difference between the mean preoperative and postoperative 1st year TBUT values in group 2 was not statistically different (p = 0.249), Schirmer I results were higher postoperatively (p = 0.003). There was no statistically significant difference between preoperative Schirmer (p = 0.496), postoperative Schirmer (p = 0.661), preoperative TBUT (p = 0.240) and postoperative TBUT (p = 0.238) results of the two groups. Recurrence was observed in only one patient from group 1. CONCLUSION: No recurrent pterygium cases were observed in group 2. Schirmer I values were higher postoperatively in group 2; thus,topical CsA treatment may improve lacrimal secretion and be effective after pterygium surgery with FG.


Asunto(s)
Ciclosporina , Adhesivo de Tejido de Fibrina , Inmunosupresores , Pterigion , Humanos , Pterigion/cirugía , Pterigion/diagnóstico , Ciclosporina/administración & dosificación , Masculino , Femenino , Persona de Mediana Edad , Adhesivo de Tejido de Fibrina/administración & dosificación , Inmunosupresores/administración & dosificación , Estudios Retrospectivos , Estudios de Seguimiento , Adulto , Adhesivos Tisulares/administración & dosificación , Adhesivos Tisulares/uso terapéutico , Resultado del Tratamiento , Anciano , Soluciones Oftálmicas/administración & dosificación , Procedimientos Quirúrgicos Oftalmológicos/métodos , Procedimientos Quirúrgicos Oftalmológicos/efectos adversos , Recurrencia , Conjuntiva , Lágrimas/metabolismo , Lágrimas/fisiología
7.
IJU Case Rep ; 7(4): 281-284, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38966775

RESUMEN

Introduction: Urinary fistula is a rare complication following robot-assisted partial nephrectomy. For cases refractory to conservative treatment, only ureteral stent placement and percutaneous drainage are the established treatment alternatives. Case presentation: A 44-year-old man presented with urinary fistula 3 weeks after robot-assisted partial nephrectomy for right renal cell carcinoma. Follow-up observations were conducted for 2 weeks; however, no improvements were observed. Additionally, the patient did not improve following percutaneous drainage and ureteral stent insertion. Subsequently, the patient received percutaneous injections of fibrin glue, with the urinary fistula showing significant improvements on the following day. Conclusion: Our findings indicated that percutaneous fibrin glue injection can effectively treat refractory urinary fistula following partial nephrectomy.

8.
Data Brief ; 55: 110623, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38993226

RESUMEN

The high volatility of the terpenes contained in flavour-containing terpene (FCT) products causes the loss of these contents during product storage; thus, measuring the loss of FCT content during storage is important to estimate the final content. This work provides data on the reduction in FCT content of infused pre-rolled paper cones after 1 to 7 days of storage. Determination of FCT content was based on the formation of a reddish-brown precipitate resulting from the reaction of terpene moiety in FCT with sulphuric acid. Then, the absorbance of the precipitate was analysed using the UV-Vis Spectrophotometric method at a visible wavelength of 538 nm. A calibration standard curve was prepared concerning the concentration of the original FCT sample and used to determine the FCT content in infused pre-rolled paper. The FCT content on the first day of storage decreased and increased again after seven days of storage due to condensation. The data on the FCT content reduction as the effect of additive added was also evaluated.

9.
Cureus ; 16(6): e62156, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38993446

RESUMEN

Uterine arteriovenous malformations (UAVMs) are rare and abnormal entanglements of uterine arteries and veins that are potentially fatal, requiring blood transfusions in about a third of cases. Although the optimal management of the condition is not well established in the literature, surgical hysterectomy is believed to be the only definitive treatment for arteriovenous malformations. We present three cases of UAVMs treated by a minimally invasive endovascular approach. Chief complaints were heavy menstrual bleeding and sudden onset heavy bleeding. The diagnosis was confirmed by computed tomography imaging and angiography of the pelvic vessels. Uterine artery embolization (UAE) was performed in all patients. The follow-up period was uneventful. In our experience, the UAE provides satisfactory results in terms of success rates, complications, and short hospital stays.

10.
Ther Deliv ; : 1-15, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39011599

RESUMEN

Aim: This study was conducted to investigate the effect of fibrin glue-CM11 antibacterial peptide mixture (FG-P) on the healing of infected wounds in vivo. Materials & methods: We formulated a mixture of FG-P and evaluated its antimicrobial activity in vitro against multidrug-resistant (MDR) bacteria involved in wound infection as well as its healing effect on wound infected by methicillin-resistant S. aureus (MRSA) in vivo. Results: The peptide had an MIC of 8 µg/ml against all bacteria isolates. Growth inhibition zones were evident for FG-P compared with FG. The in vivo study showed that the FG-P could be significantly effective in healing the MRSA-infected wound. Conclusion: The use of FG-P mixture is a very suitable option for treating infected wounds.


[Box: see text].

11.
Neurol Res ; : 1-10, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007696

RESUMEN

OBJECTIVES: For nerve injuries, not amendable to tensionless epineural coaptation of the nerve, autografts are the preferred treatment. Although absorbable sutures are not recommended for nerve repair, there is no evidence that non-absorbable sutures are superior to absorbable sutures. This study aims to assess the effectiveness of non-absorbable monofilament nylon sutures, absorbable monofilament vicryl sutures, and fibrin glue when used for nerve grafting. METHODS: Lewis rats (N = 32) were subjected to a sciatic nerve transection and randomly assigned to a group: graft with Nylon, graft with Vicryl, graft with Fibrin Glue, or no graft. Motor function, sensory function, and thermal pain were assessed during a 12-week recovery period, and immunohistochemistry was used to assess macrophage response. RESULTS: At 12 weeks, the Vicryl and Nylon groups had significantly larger ankle angles at to lift off, which is a measure of motor function, compared to injured controls (p < 0.05). Grafted rats displayed no difference in thermal response but hypersensitivity to mechanical stimuli compared to the uninjured hindlimb. The Nylon, Vicryl, and Fibrin Glue groups all had significantly less atrophy of the gastrocnemius muscle compared to injured controls (p < 0.0001). In the Fibrin Glue group, 3/9 grafts did not incorporate. The Nylon group had significantly less (p = 0.0004) axon growth surrounding the suture holes compared to the Vicryl group. There were no differences in the axon counts, motor neurons, or sensory neurons between all grafted rats. CONCLUSIONS: These results demonstrate that vicryl sutures work just as well as nylon for nerve recovery after injury and grafting.

12.
Front Oncol ; 14: 1392213, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39070140

RESUMEN

Background: Through preoperative localization, surgeons can easily locate ground glass nodules (GGNs) and effectively control the extent of resection. Therefore, it is necessary to choose an appropriate puncture positioning method. The purpose of this study was to evaluate the effectiveness and safety of medical glue and positioning hooks in the preoperative positioning of GGNs and to provide a reference for clinical selection. Methods: From March 30, 2020 to June 13, 2022, a total of 859 patients with a CT diagnosis of GGNs requiring surgical resection were included in our study at the hospital. Among them, 21 patients who either opted out or could not undergo preoperative localization for various reasons were excluded. Additionally, 475 patients who underwent preoperative localization using medical glue and 363 patients who underwent preoperative localization through positioning hooks were also excluded. We conducted statistical analyses on the baseline data, success rates, complications, and pathological results of the remaining patients. The success rates, complication rates, and pathological results were compared between the two groups-those who received medical glue localization and those who received positioning hook localization. Results: There was no statistically significant difference between the two groups of patients in terms of age, body mass index, smoking history, location of the nodule, distance of the nodule from the pleura, or postoperative pathological results (P > 0.05). The success rate of medical glue and positioning hooks was 100%. The complication rates of medical glue and positioning hooks during single nodule positioning were 39.18% and 23.18%, respectively, which were significantly different (p < 0.001); the complication rates during multiple nodule positioning were 49.15% and 49.18%, respectively, with no statistically significant differences (p > 0.05). In addition, the method of positioning and the clinical characteristics of the patients were not found to be independent risk factors for the occurrence of complications. The detection rate of pulmonary nodules also showed some positive correlation with the spread of COVID-19 during the 2020-2022 period when COVID-19 was prevalent. Conclusion: When positioning a single node, the safety of positioning hooks is greater than when positioning multiple nodes, the safety of medical glue and positioning hooks is comparable, and the appropriate positioning method should be chosen according to the individual situation of the patient.

13.
Angew Chem Int Ed Engl ; : e202409629, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39058372

RESUMEN

Carbon aerogels (CAs) are attracting great attention for their multifunctional applications. Additionally, a large amount of biomass bits waste generated from agriculture and industry is regarded as the main carbon resource. However, the development of a facile, sustainable, and efficient method to produce CAs from biomass waste remains challenging. Here, a one-step Zn2+ ions glue triggered carbonization technology was reported to construct large-scale and high-performance CAs. Multiple biomass bits (wood bits, peanut shells, bamboo bits, and straw waste) were treated in the molten salt system (ZnCl2/KCl) at 300 °C for 2h to obtain large-block biomass bits derived CAs. Zn2+ ions as the glue cleavage cellulose hydrogen bonds of natural biomass, then facilitate dehydration crosslinking reaction between cellulose, hemicellulose, and lignin for re-constructing the whole block structure. The obtained CAs show high porosity (95%) and low density (0.078 g/cm3). Meanwhile, numerous of hydroxyl and carbonyl groups were well maintained during low temperature treated process, which facilitate chemical modification for various applications. For instance, amidoxime functionalized CAs were utilized as a filter for selective and highly efficient extraction of U(VI) from wastewater. The adsorption capacity and extraction efficiency reached 801.2 mg/g and 95% with a flux rate of 6.1×103 L/m2·h, respectively.

14.
Lung Cancer ; 194: 107886, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-39047616

RESUMEN

The Kirsten rat sarcoma viral oncogene homolog (KRAS) is one of the first driver oncogenes identified in human cancer in the early 1980s. However, it has been deemed 'undruggable' for nearly four decades until the discovery of KRAS G12C covalent inhibitors, which marked a pivotal breakthrough. Currently, sotorasib and adagrasib have been approved by the US FDA to treat patients with non-small cell lung cancer (NSCLC) harboring KRAS G12C mutation. However, their efficacy is somewhat limited compared to that of other targeted therapies owing to intrinsic resistance or early acquisition of resistance. While G12C is the predominant subtype of KRAS mutations in NSCLC, G12D/V is prevalent in colorectal and pancreatic cancers. These facts have spurred active research to develop more potent KRAS G12C inhibitors as well as inhibitors targeting non-G12C KRAS mutations. Novel approaches, such as molecular shielding or targeted protein degradation, are also under development. Combining KRAS inhibitors with inhibitors of the receptor-tyrosine kinase-RAS-mitogen-activated protein kinase (MAPK) pathway is underway to counteract redundant feedback mechanisms. Additionally, immunological approaches utilizing T-cell receptor (TCR)-engineered T cell therapy or vaccines, and Hapimmune antibodies are ongoing. This review delineates the recent advancements in KRAS inhibitor development in the post-sotorasib/adagrasib era, with a focus on NSCLC.

15.
Int J Biol Macromol ; 277(Pt 1): 133653, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38992534

RESUMEN

Ecofriendly hydrogels were prepared using chitosan (CH, 285 kDa) and two fractions of low molecular weight microbial poly-γ-glutamic acid (γ-PGA) (R1 and R2 of 59 kDa and 20 kDa, respectively). The hydrogels were synthesized through sustainable physical blending, employing three CH/γ-PGA mass ratios (1/9, 2/8, and 3/7), resulting in the formation of physically crosslinked materials. The six resulting CH/R1 and CH/R2 hydrogels were physico-chemically characterized and the ones with the highest yields (CH/R1 and CH/R2 ratio of 3/7), analyzed for rheological and morphological properties, showed to act as bio-glues on wood and aluminum compared to commercial vinyl- (V1) and acetovinyl (V2) glues. Lap shear analyses of CH/R1 and CH/R2 blends exhibited adhesive strength on wood, as well as adhesive/cohesive failure like that of V1 and V2. Conversely, CH/R2 had higher adhesive strength and adhesive/cohesive failure on aluminum, while CH/R1 showed an adhesion strength with adhesive failure on the metal similar to that of V1 and V2. Scanning electron microscopy revealed the formation of strong physical bonds between the hydrogels and both substrates. Beyond their use as bio-adhesives, the unique properties of the resulting crosslinked materials make them potentially suitable for various applications in paint, coatings, heritage preservation, and medical sector.

16.
J Ethnopharmacol ; 335: 118575, 2024 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-39009326

RESUMEN

ETHNOPHARMACOLOGICAL RELEVANCE: Guilu Erxian Glue (GEG) and Danggui Buxue Tang (DBT) are traditional Chinese herbal formulas. According to the theory of traditional Chinese medicine, the combination of those two formulas (Modified Guilu Erxian Glue, MGEG) has the effects of tonifying the kidney and producing blood, was usually used to treat bone marrow failure diseases, including aplastic anemia (AA). AIM OF THE STUDY: T lymphocytes play a crucial role in the disease pathogenesis and progression of AA. Our preliminary results confirmed that GEG can improve the damage of hematopoietic stem cells in mice, while DBT can reduce the proliferation and differentiation of T lymphocytes and inhibit the production of IFN-γ. We hypothesized that the combination of those two herbal formulas could inhibit immune attack and restore hematopoietic function through multiple mechanisms. In this study, we aim to study the curative effect of MGEG on regulating the expression of Signal lymphocyte activating molecule (SLAM), an activation-related molecule in T lymphocytes, thereby suppressing the immune function of T cells and decelerating the damage to hematopoietic stem cells. MATERIALS AND METHODS: High-performance liquid chromatography-electrospray ionization/mass spectrometry system was used to identify the components of the MGEG formulation. Induction of aplastic anemia mouse model by injecting allogeneic lymphocyte suspension into BABL/c mice after ionizing radiation. Cyclosporine A (CsA) was used as a positive control drug. Flow cytometry was used to detect the number and apoptosis rate of hematopoietic stem cells in the bone marrow. Enzyme-linked immunosorbent assay was performed to measure the levels of IFN-γ and TNF-α. Immunofluorescence staining was used to assess the expression of T-bet and SLAM-SAP. Western Blot was conducted to examine the expression of activation-related molecules in T lymphocytes and proteins related to the Fas signal pathway. Hematoxylin-eosin staining was performed to observe pathological changes in the bone marrow tissue. Wright-Giemsa staining was utilized to evaluate alterations in the cellular composition and basic structure of the bone marrow cells (BMCs). Transmission electron microscopy was employed to observe changes in the structure and morphology of hematopoietic stem cells. The hematology analyzer was used to detect peripheral blood parameters. RESULTS: Twenty-three different components were identified in MGEG. After MGEG treatment, the expression levels of Fyn and SLAM-SAP binding were increased in AA mice, while the expression levels of T-bet were decreased and the secretion of IFN-γ was reduced significantly. Additionally, MGEG also could downregulate the protein levels of Fas, caspase-3, and cleaved caspase-3 in AA mice. CONCLUSION: MGEG could attenuate the production of IFN-γ by promoting the SLAM-SAP signal pathway to regulate the generation and distribution of T-bet in T cells. Additionally, it suppresses apoptosis of HSCs through intervention in the Fas-dependent pathway, thereby mitigating immune-mediated damage to HSCs.

17.
Cureus ; 16(6): e63111, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39055456

RESUMEN

BACKGROUND: Nerve injuries have traditionally been repaired with sutures, and this method is considered the gold standard technique in the management of nerve injuries. However, fibrin glue has recently become a promising tool for repairing nerve injuries and has advantages including ease of usability, atraumatic application technique, and decreased co-optation time of the nerves. This study aims to clinically evaluate the efficacy of nerve repair with fibrin glue compared with the usual suture technique in terms of sensory and motor outcomes. METHODS: A total of 80 patients were included in the study; 50 patients underwent primary nerve repair, and 30 patients underwent Oberlin's repair. These subsets were randomly divided into two groups in which the nerves were repaired with microsutures in one group and fibrin glue in the other group. RESULTS: In the comparison of fibrin glue with microsutures, there were no significant differences between the two groups in the 2-point discrimination (2PD) test, Semmes-Weinstein test, motor function, and Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire scores. However, the co-optation times were significantly shorter with fibrin glue than with microsutures. CONCLUSION: Based on our findings, nerve repair with fibrin glue is as effective as microsutures in terms of sensory and motor recovery and has added advantages of ease of usability and shorter repair times. Therefore, fibrin glue may be an effective alternative to sutures in nerve repair.

18.
J Surg Case Rep ; 2024(6): rjae385, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38835941

RESUMEN

We report a 3-year-old girl who presented to our clinic with a left-sided neck mass at the junction of the middle and lower thirds of the anterior border of the sternocleidomastoid with a slight tenderness. The patient was then diagnosed with a branchial cleft and was taken for surgical excision. Intraoperatively, we injected methylene blue with fibrin glue using an arterial catheter inside the tract, which facilitated the dissection of the tract.

19.
Innov Surg Sci ; 9(1): 47-54, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38826631

RESUMEN

Objectives: Various techniques of closure of surgical incisions have been described ranging from various suture materials, staples and tapes to adhesive compounds. Cyanoacrylate is an adhesive compound available for surgical incision closure. Although sutures have been the preferred universal choice for surgical incision closure, glue is gaining popularity in specific places like pediatric injuries, facial injuries, laparoscopic incision closure, etc. This study aimed to compare the results between the application of cyanoacrylate and conventional suturing. Methods: In this randomized control study, patients were divided into two groups of 100 each. The surgical incisions were closed using cyanoacrylate glue in Group A patients and polyamide (EthilonTM 2-0) in Group B patients. Post-operative pain was assessed using Visual Analogue Scale on the first, third, and seventh day. The wounds were evaluated for complications on post-op days 1, 3, 7, and 30 using the ASEPSIS score. Cosmetic outcome was assessed at the end of first month using the Modified Hollander Cosmesis Scale. Results: Post-operative pain was significantly less in the glue group on days 1, 3, and 7. Wound infection with dehiscence occurred in 4 cases (4 %) in Group A and one patient (1 %) in Group B, which was statistically insignificant. There was no significant difference in cosmetic outcomes in either Group. Conclusions: Cyanoacrylate is a good alternative to sutures in skin closure of clean and clean-contaminated surgical wounds.

20.
Chemistry ; : e202401399, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38867468

RESUMEN

Bacterial conjugation, a commonly used method to horizontally transfer functional genes from donor to recipient strains, plays an important role in the genetic manipulation of bacteria for basic research and industrial production. Successful conjugation depends on the donor-recipient cell recognition and a tight mating junction formation. However, the efficiency of conjugative transfer is usually very low. In this work, we developed a new technique that employed DNA molecule "glue" to increase the match frequency and the interaction stability between the donor and recipient cells. We used two E. coli strains, ETZ and BL21, as a model system, and modified them with the complementary ssDNA oligonucleotides by click chemistry. The conjugation efficiency of the modified bacteria was improved more than 4 times from 10% to 46%. This technique is simple and generalizable as it only relies on the active amino groups on the bacterial surface. It is expected to have broad applications in constructing engineered bacteria.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA