Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Vet Ophthalmol ; 2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-37985376

RESUMEN

OBJECTIVE: To report the outcomes of sequential Ahmed valve implantation in two dogs with uncontrolled intraocular pressure (IOP) after primary Ahmed valve implantation. ANIMALS STUDIED: A 6-year-old castrated male American Cocker Spaniel (case 1) and a 12-year-old spayed female mixed-breed dog (case 2) presented with glaucoma management in the left eyes of both dogs. PROCEDURES: Primary Ahmed valve implantation was performed because of uncontrolled IOP despite antiglaucoma medications used in both dogs. The IOP was maintained within the normal range for 14 and 2 months after surgery in cases 1 and 2, respectively. In both cases, the IOP gradually increased, which was assumed to be caused by bleb fibrosis. In particular, in case 2, one bleb revision surgery was performed during that period, but it was unsuccessful. Therefore, we decided to perform sequential implantation surgery. RESULTS: In case 1, hyphema occurred the day after sequential surgery and resolved with anti-inflammatory treatment. In case 2, it occurred immediately after the surgery and resolved after surgical blood clot removal. IOP remained below 15 mmHg, and menace response was positive until 40 and 23 months after the sequential surgery in cases 1 and 2, respectively. As a long-term complication, cataracts occurred at 17 months in case 1 and 10 months in case 2. CONCLUSIONS AND CLINICAL RELEVANCE: Sequential implantation surgery in the same eye could be an effective alternative for long-term IOP management and vision maintenance. A better understanding of complications and appropriate postoperative management is essential for better outcomes.

2.
Vet Ophthalmol ; 24 Suppl 1: 109-115, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33609423

RESUMEN

OBJECTIVE: To report outcomes and follow-up of Baerveldt implant surgery in dogs with primary closed-angle glaucoma (PCAG). MATERIALS AND METHODS: Record review of client-owned dogs with PCAG that underwent Baerveldt implant surgery during a 6-year period. Postoperative intraocular pressure (IOP), vision and daily number of anti-glaucoma drops at fixed time points (3, 12, and 24 months) were compared with preoperative values; complications were recorded. Success was defined as IOP <20 mm Hg and a positive menace response and navigation/tracking ability. RESULTS: Twenty eyes (17 dogs) were included. Mean follow-up was 575 days (range 30-1767 days) from implant surgery to last examination. Three months postoperatively 15/20 (75%) eyes had IOP <20 mm Hg and 14/20 (70%) eyes had vision. Twelve months postoperatively 11/17 (65%) eyes had IOP <20 mm Hg and 12/19 (63%) eyes had vision. Twenty-four months postoperatively 8/14 (57%) eyes had IOP <20 mm Hg and 7/15 (47%) eyes had vision. Denominators differ between time points as eyes were included when duration after surgery reached the relevant postoperative time point or failure was documented earlier. Within 3 months postoperatively 16/20 (80%) eyes had ≥1 complication, including transient IOP >20 mm Hg (14/20; 70% eyes), fibrin (12/20; 60% eyes), and hypotony (4/20; 20% eyes). After 3 months, postoperatively 13/16 (81%) eyes had ≥1 complication, including cataracts (13/16; 81% eyes), bleb fibrosis (3/16; 19% eyes), and conjunctival wound breakdown (1/16; 6% eyes). One patient (1 eye) was euthanized for blindness and 5/20 (25%) eyes were enucleated. CONCLUSIONS: The technique was effective in controlling IOP and maintaining vision in most dogs in this study.


Asunto(s)
Enfermedades de los Perros/cirugía , Implantes de Drenaje de Glaucoma/veterinaria , Glaucoma de Ángulo Cerrado/veterinaria , Animales , Catarata/etiología , Catarata/veterinaria , Perros , Femenino , Estudios de Seguimiento , Implantes de Drenaje de Glaucoma/efectos adversos , Glaucoma de Ángulo Cerrado/cirugía , Masculino , Resultado del Tratamiento
3.
Vet Ophthalmol ; 24 Suppl 1: 34-38, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33332728

RESUMEN

Glaucoma is a disorder of all species due to a rise of intraocular pressure (IOP) beyond which is compatible with ganglion cell and axon function, often resulting in optic nerve degeneration and irreversible blindness. Glaucoma treatment with surgical intervention aimed at either reducing aqueous production, or increasing or altering aqueous outflow has evolved over preceding decades, but there remains no cure. The present article is intended to provide a concise review of glaucoma surgical therapies in veterinary ophthalmology.


Asunto(s)
Glaucoma/veterinaria , Animales , Glaucoma/cirugía , Humanos
4.
Vet Ophthalmol ; 21(5): 487-497, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29383822

RESUMEN

OBJECTIVE: To compare outcomes following trans-scleral cyclophotocoagulation (TSCP) and 350-mm2 Baerveldt implantation in the treatment of canine refractory glaucoma. DESIGN: Retrospective case study. CASE SELECTION: Client owned dogs undergoing surgical treatment of glaucoma within a veterinary referral hospital. PROCEDURES: Eighty-six glaucoma surgeries were performed on 83 eyes (69 dogs) diagnosed with primary or secondary glaucoma. Medical records were retrieved, and baseline data, surgery, medications, intraocular pressures (IOPs), vision, and complications were extracted. RESULTS: Fifty-four eyes (44 dogs) were treated with TSCP and placement of an anterior chamber suture shunt; 28 eyes (24 dogs) were implanted with a Baerveldt glaucoma drainage device (GDD); and four eyes (4 dogs) underwent GDD implantation after failure of TSCP to manage IOP. Following TSCP, IOP control (<20 mmHg) and vision retention occurred in 81.5% and 42.6%, respectively, for 16.1 ± 1.36 months. Following GDD implantation, 71.4% maintained IOP <20 mmHg and 69.6% maintained vision for 11.0 ± 0.94 months. IOP control without loss of vision was more likely following Baerveldt implantation (17/28; 60.7%) than TSCP (19/54; 35.2%) (P = 0.027). One eye had functional vision restored following GDD placement. IOP control without adjunctive medications was more likely following Baerveldt implantation (P = 0.02). CONCLUSIONS: In this study, eyes treated with Baerveldt GDD implantation were more likely to maintain IOP control and retain vision compared to eyes treated with TSCP and placement of an anterior chamber suture shunt. Lack of formal randomization, inconsistencies in surgical techniques and TSCP protocols, and potential unmeasured confounders must be considered when extrapolating from this retrospective study.


Asunto(s)
Enfermedades de los Perros/cirugía , Glaucoma/veterinaria , Animales , Perros , Femenino , Glaucoma/cirugía , Implantes de Drenaje de Glaucoma/veterinaria , Láseres de Semiconductores , Masculino , Complicaciones Posoperatorias , Implantación de Prótesis/veterinaria , Estudios Retrospectivos , Resultado del Tratamiento
5.
Vet Ophthalmol ; 21(1): 96-100, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27539152

RESUMEN

An Ahmed valve implantation with an Ologen® Collagen Matrix (Ologen® CM, Aeon Astron, Leiden, the Netherlands) was performed for the treatment of uncontrolled glaucoma in a cat. This cat was a 5-year-old castrated Russian Blue male with a 12-week history of conjunctival hyperemia and mydriasis of the left eye. During the ophthalmic examination, the intraocular pressure (IOP) oculus sinister (OS) was 52 mmHg, and a narrow iridocorneal angle (ICA) was detected by gonioscopy. Medical treatment with Cosopt® (2% dorzolamide and 0.5% timolol) failed to decrease the IOP. The left eye still had vision, and an Ahmed valve implantation was performed. During the gonioimplantation, Ologen® CM was used to inhibit scar formation around the valve. Following the operation, the IOP was stable at an approximate average of 15 mmHg during the 7-month follow-up period, and vision in the left eye was retained without medication. An adequate subconjunctival filtering bleb was formed after 140 days. This is the first case report in which an Ahmed valve gonioimplant with an Ologen® CM has been used for the surgical treatment of glaucoma in a cat.


Asunto(s)
Enfermedades de los Gatos/cirugía , Colágeno , Implantes de Drenaje de Glaucoma/veterinaria , Glaucoma/cirugía , Glicosaminoglicanos , Animales , Gatos , Presión Intraocular , Masculino , Linaje , Resultado del Tratamiento
6.
Vet Ophthalmol ; 20(5): 427-434, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27860168

RESUMEN

OBJECTIVE: To evaluate the 350-mm2 Baerveldt glaucoma drainage device (GDD) in dogs with refractory glaucoma when modifications to address postoperative hypotony (extraluminal ligature; intraluminal stent) and the fibroproliferative response (intraoperative Mitomycin-C; postoperative oral colchicine and prednisolone) are implemented as reported in human ophthalmology. DESIGN: Retrospective case series. ANIMALS: Twenty-eight client-owned dogs (32 eyes) including seven dogs (nine eyes) with primary glaucoma and 21 dogs (23 eyes) with secondary glaucoma. METHODS: The medical records of all dogs undergoing placement of a 350-mm2 Baerveldt GDD at a veterinary ophthalmology referral service between 2013 and 2016 were reviewed. Signalment, diagnosis, duration and previous treatment of glaucoma, previous intraocular surgery, IOP, visual, and surgical outcomes were recorded. RESULTS: IOP was maintained <20mmHg in 24 of 32 (75.0%) eyes. Fourteen eyes (43.8%) required no adjunctive treatments to maintain this IOP control. Fewer doses of glaucoma medication were required following surgery. Vision was retained in 18 of 27 (66.7%) eyes with vision at the time of surgery. No eyes that were blind at the time of surgery (n = 5) had restoration of functional vision. Complications following surgery included hypotony (26/32; 81.3%), intraocular hypertension (24/32; 75.0%), and fibrin formation within the anterior chamber (20/32; 62.5%). The average follow-up after placement of the GDD was 361.1 days (median 395.6 days). CONCLUSION: Efforts to minimize postoperative hypotony and address the fibroproliferative response following placement of a 350-mm2 Baerveldt GDD showed an increased success rate to other reports of this device in dogs and offers an alternative surgical treatment for controlling intraocular pressure in dogs with glaucoma.


Asunto(s)
Enfermedades de los Perros/terapia , Implantes de Drenaje de Glaucoma/veterinaria , Glaucoma/veterinaria , Presión Intraocular , Hipotensión Ocular/veterinaria , Complicaciones Posoperatorias/veterinaria , Animales , Perros , Glaucoma/terapia , Humanos , Hipotensión Ocular/prevención & control , Complicaciones Posoperatorias/prevención & control , Estudios Retrospectivos , Resultado del Tratamiento , Agudeza Visual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA