Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 169
Filtrar
1.
BMC Oral Health ; 24(1): 852, 2024 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-39068402

RESUMEN

BACKGROUND: Interim crowns are utilized for restoring implants during and after the process of osseointegration. However, studies on adaptation and fracture strength of implant-supported interim crowns are rare. AIM OF THE STUDY: The aim of this in vitro study is evaluating marginal fit and fracture resistance of conventional, subtractive, and additive methods of fabricating implant-supported interim crowns. MATERIALS AND METHODS: An implant was placed in an epoxy resin model with a missing first molar. A scan body was attached, and scanned with an intraoral scanner (IOS), the STL file was used to fabricate eighteen master models with standardized implant digital analogue spaces. The digital analogues and their corresponding abutments were attached to the master models and scanned with the IOS, the STL files were used to fabricate eighteen crowns using three different techniques (n = 6): conventional (CR); from Autopolymerizing composite resin, subtractive (SM); milled from PMMA resin blanks, and additive (AM); from 3D printed resin material. The crowns were fitted and cemented on their corresponding abutments and subjected to cyclic loading and thermocycling. The marginal fit was evaluated using a stereomicroscope. The crowns were then loaded until fractured in a universal testing machine. The Shapiro-Wilk and the Kolmogorov-Smirnov tests revealed that data of Marginal gap was non-parametric. Kruskal-Wallis test followed by the Dunn test was used (α = 0.05). While data of Fracture resistance test was parametric. ANOVA (F-test) was used followed by the Tukey test (α = 0.05). RESULTS: For marginal gap, a significant difference was shown between the study groups (P = .001) according to Kruskal-Wallis test. Groups SM and AM had significantly lower marginal gap values compared to group CR (P = .003). No significant difference was found between groups SM and AM (P = .994). For fracture resistance, One-way ANOVA revealed a significant difference in fracture resistance between study groups (P < .001). Group SM had significantly higher fracture strength followed by group AM and group CR (P = .001). CONCLUSIONS: Group SM and AM showed better marginal adaptation than group CR. Group SM showed superior fracture resistance compared to other groups. All study groups showed acceptable marginal gap and fracture resistance.


Asunto(s)
Coronas , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Humanos , Técnicas In Vitro , Adaptación Marginal Dental , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Diseño Asistido por Computadora , Ensayo de Materiales
2.
J Pharm Bioallied Sci ; 16(Suppl 2): S1404-S1408, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38882827

RESUMEN

Purpose: The aim of the in vitro study was to compare the internal merge and marginal perfection of polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) crowns under a stereomicroscope. Methods: All-ceramic preparation is done on the maxillary first premolar which is mounted on the wax block which was scanned using 3Shape scanner and duplicated into 30 acrylic CAD/CAM dies (n = 15) for the placement of PEEK and PEKK crowns. The YENADENT milling system was used to fabricate 15 samples from Group A PEEK crowns and to fabricate 15 samples from Group B PEKK crowns. According to the manufacturer's instructions, an equal amount of the dual-cure resin luting agent (Rely X U200 Self-Adhesive resin, 3M, Germany) was dispensed on the mixing pad before being mixed with cement and painted on the internal surfaces of the copings with the finger pressure crowns which were luted. The values were then analyzed using one-way ANOVA (post hoc) followed by Dunnett's t-test. Results: Among those two groups, PEEK group materials showed the lowest mean value of (28.73.3 ± 4.01) for marginal fit and (26.72 ± 2.53) for internal gap, whereas PEKK group showed a mean value of (32.85 ± 4.63) and (33.06 ± 4.14), respectively. Conclusion: Among these two groups, comparatively less marginal fit and internal adaptation is seen in PEKK when compared to the PEEK crowns. While the marginal fit and internal adaptation of both PEEK and PEKK copings were in acceptable clinical range.

3.
Saudi Dent J ; 36(6): 887-893, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38883896

RESUMEN

Purpose: This prospective study evaluated the effects of the metal-free crowns on the periodontal tissues of abutment teeth during a 12-month follow-up. Materials and Methods: A sample of 24 patients (N = 32 abutment teeth) who needed a single-tooth restoration were enrolled to receive either a metal-ceramic (n = 21) or lithium disilicate (n = 11). The single-unit crowns were evaluated at baseline, 3-and 12-month follow-up. The periodontal parameters were evaluated: plaque index (PI), gingival bleeding index (GBI), bleeding on probing (BOP), probing depth (PD), clinical attachment loss (CAL), radiographically and clinical crown fitting, bone resorption, and marginal finish lines. Statistical analyses were performed using the Exact Fisher and Mann-Whitney tests, and the Wilcoxon signed-rank test as a post hoc test for Friedman (95 % confidence interval). Results: The marginal finish line showed a statistical difference with a biomaterial type (p =.004). After a 12-months, a significant increase was observed in PI and mean PD for abutment teeth of metal-ceramic crowns. The metal-free crowns presented higher values for GBI and CAL (p2 < 0.05). Only distal cervical evaluation and dental biofilm formation in the abutment teeth showed a statistical difference between the groups at the 12-month follow-up. The supragingival margin metal-ceramic group revealed higher PI values (p2 = 0.005) between the period and the subgingival margin of both biomaterials showed greater GBI scores (p2 < 0.05). Conclusions: Metal-free crowns showed better periodontal outcomes compared to metal-ceramic crowns. Single-unit crown marginal location affects the periodontal tissue condition of the abutment teeth. The marginal fit was not changed regarding the biomaterial type.

4.
Materials (Basel) ; 17(9)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38730936

RESUMEN

The marginal accuracy of fit between prosthetic restorations and abutment teeth represents an essential aspect with regard to long-term clinical success. Since the final gap is also influenced by the luting techniques and materials applied, this study analyzed the accuracy of the fit of single-tooth zirconia copings before and after cementation using different luting materials. Forty plaster dies with a corresponding zirconia coping were manufactured based on a single tooth chamfer preparation. The copings were luted on the plaster dies (n = 10 per luting material) with a zinc phosphate (A), glass-ionomer (B), self-adhesive resin (C), or resin-modified glass-ionomer cement (D). The accuracy of fit for each coping was assessed using a non-destructive digital method. Intragroup statistical analysis was conducted using Wilcoxon signed rank tests and intergroup analysis by Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). Accuracy of fit was significantly different before/after cementation within A (0.033/0.110 µm) and B (0.035/0.118 µm; p = 0.002). A had a significantly increased marginal gap compared to C and D, and B compared to C and D (p ≤ 0.001). Significantly increased vertical discrepancies between A and B versus C and D (p < 0.001) were assessed. Of the materials under investigation, the zinc phosphate cement led to increased vertical marginal discrepancies, whereas the self-adhesive resin cement did not influence the restoration fit.

5.
J Funct Biomater ; 15(5)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38786641

RESUMEN

This study aimed to compare the impact of CAD/CAM closed systems and open systems on the marginal gap of monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns, as both systems are used in everyday dentistry, both chair-side and laboratory. For the closed system, 20 plastic teeth were scanned by a Primescan intra-oral scanner (IOS), and for the open system, the same number of plastic teeth were scanned by Trios 4 IOS. For the closed system, CEREC software was used, and for the open system, EXOCAD software was used. All 40 ZLS crowns were grinded by the same four-axis machine and cemented with Temp-bond, followed by self-adhesive resin cement. For each type of cement, an evaluation of the marginal gap was conducted by scanning electron microscopy (SEM). Before comparisons between the groups, a Kolmogorov-Smirnov test was performed on the study variables showing a normal distribution (p > 0.05). Independent T tests (α = 0.05) and paired-sample T tests (α = 0.05) were used. The independent T test found no significant mean marginal gap differences in the zirconia-reinforced lithium silicate crowns bonded with Temp-bond and scanned by Primescan (28.09 µm ± 3.06) compared to Trios 4 (28.94 µm ± 3.30) (p = 0.401), and there was no significant mean marginal gap differences in zirconia-reinforced lithium silicate crowns bonded with self-adhesive resin cement (Gcem ONE) and scanned by Primescan (46.70 µm ± 3.80) compared to Trios 4 (47.79 µm ± 2.59) (p = 0.295). Paired-sample T tests showed significantly higher mean marginal gaps with Gcem ONE compared to Temp-bond for the total mean marginal gap when scanning with Primescan (p = 0.0005) or Trios 4 (p = 0.0005). In everyday dentistry, both closed systems (Primescan with Cerec) and open systems (Trios 4 with Exocad) can be used to achieve an acceptable (<120 µm) marginal gap for ZLS CELTRA® DUO single crowns. There is a significant difference between cementation with Temp-bond and Gcem ONE self-adhesive resin cement (p < 0.05).

6.
J Conserv Dent Endod ; 27(2): 140-145, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38463477

RESUMEN

The accuracy of the digital impression method is responsible for fabricating crowns with adequate marginal fit which in turn determines the postendodontic prognosis. This systematic review was undertaken to identify the influence of the two digital impression techniques in producing full coverage crowns with better marginal fit. This systematic review was conducted according to the Preferred Reporting Items for Systematic Review and Meta-analysis statement. A detailed search was done in electronic databases (PubMed, EBSCOhost, LILACS, Cochrane) along with hand searches of reference articles. In vivo crossover studies comparing the marginal fit of the computer-aided design-computer-aided manufacturing (CAD-CAM) fabricated crowns from direct and indirect digital impressions published from inception till July 2023 were included in this review. The quality assessment of the included articles was done based on a modified Cochrane collaboration tool for crossover studies. A total of 280 articles were identified, after duplicate removal, title and abstract screening, and full-text evaluation, 7 articles were included in this systematic review. The overall quality of evidence is moderate. The CAD-CAM crowns fabricated from direct digital impressions exhibited a better marginal fit than those crowns fabricated by indirect digital impressions. The overall quality of evidence is moderate. Further clinical studies has to be conducted for evaluating the latest technologies towards achieving the misfit of zero.

7.
Dent J (Basel) ; 12(3)2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38534285

RESUMEN

BACKGROUND: This study compared the influence of crystallization on marginal gap adaptation by using computer-aided design and manufacturing (CAD-CAM) for producing monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns. METHODS: A total of 25 plastic teeth were scanned using a Primescan intra-oral scanner (IOS), and ZLS crowns were ground. For each unit (abutment and crown), the marginal gap was evaluated pre crystallization and post crystallization at four regions of interest through the use of a scanning electron microscope (SEM). To compare the marginal gap between the two groups, a Kolmogorov-Smirnov test performed on the study variables indicated a normal distribution (p > 0.05) followed by paired samples T-tests (α = 0.0005). RESULTS: After crystallization, there were significantly higher circumferential marginal gaps (CMGs) for all four surfaces (distal (p = 0.0005), mesial (p = 0.0005), palatal (p = 0.0005), and buccal (p = 0.0005)). The total mean marginal gap (MMG) revealed a significantly higher result for the post-crystallization group (79.82 ± 7.86 µm) compared to the pre-crystallization group (24.25 ± 5.49 µm). CONCLUSIONS: The post-crystallization group showed a significantly higher marginal gap compared to the pre-crystallization group in all parameters, but both groups were in the clinically accepted threshold (<120 microns). In terms of the marginal gap, it is arguable whether to carry out post-crystallization for CELTRA® DUO crowns and achieve better mechanical properties but significantly increase the marginal gap.

8.
Polymers (Basel) ; 16(5)2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38475296

RESUMEN

The aim of this study was to investigate the marginal fit and bond strength characteristics of onlay restorations manufactured by three-dimensional printing (Varseo XS, Bego GmbH, Bremen, Germany) and CAD/CAM (CAMcube, Montreal, QC, Canada) systems. Class II onlay cavities on sixty mandibular molars were prepared in cavities and restored in three separate groups using different fabrication methods. Digital and conventional impressions were taken to design the restorations in the CAD system (DWOS, Straumann GmbH, Freiburg, Germany). To evaluate the marginal fit and void volumes, all specimens were scanned with microcomputed tomography. A microshear test was performed to compare the bond strength of the restorations to the tooth surface. The marginal fit values measured for the 3D-printed and CAD/CAM onlay restorations were found to be at clinically acceptable levels (<120 µm), and no significant difference could be observed between the three different fabrication methods (p > 0.05). According to the microshear test results, the CAD/CAM group had the highest bond strength values before (34.82 MPa) and after (26.87 MPa) thermal cycling (p < 0.05), while the 3D-printed and conventionally produced onlays had similar results (p < 0.05). 3D printing technology is a promising option for indirect restorations; however, the post-production phase is as crucial as the printing and cementation phases.

9.
Heliyon ; 10(6): e26737, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38500976

RESUMEN

Aim: The aim of this study is to investigate the effect of the aging process on the marginal fit and fracture resistance of temporary crowns prepared using different materials. Materials and method: The steel die to represent the maxillary first premolar used in this study was produced on a CNC turning machine to include an anatomical occlusal surface. A total of 160 epoxy resin dies were obtained by taking impressions with conventional impression methods on the metal die. Epoxy resin dies were randomly divided into four groups. Temporary crowns were prepared for each group from poly acrylic resin (Vita CADTemp®), bis-acryl composite resin (Protemp 4), poly methyl methacrylate (PMMA; Imident) and poly ethyl methacrylate (PEMA; Dentalon Plus) restorative materials. Half of the specimens (n = 20) in each group (n = 40) were randomly separated and the aging process was applied 5000 times in the device. Marginal gap measurements on epoxy resin dies were made using a stereomicroscope. The fracture strength test of the specimens was performed by using the Instron Universal Test Device. Jamovi 2.2.5 statistical program was used for statistical analysis. Results: When compared to temporary crowns prepared from all other materials, poly acrylic resin (Vita CADTemp ®) temporary crowns observed significantly lower marginal gap values (59,05 µm) regardless of the aging process, and a significantly higher fracture resistance (478,44 N) in the presence of aging process (p < .05 for each). While the highest marginal gap value was detected in PMMA (Imident) (120.36 µm) temporary crowns with aging process, the lowest marginal gap value was observed in poly acrylic resin (Vita CADTemp®) (59.05 µm) crowns without non-aging process. The marginal fit and fracture resistance of all temporary crowns were negatively affected by the aging process. Conclusion: Our findings revealed the superiority of poly acrylic resin (Vita CADTemp®) crowns to the temporary crowns prepared from all other materials in terms of the significantly lower marginal gap in the absence of aging process, and the significantly higher fracture resistance in the presence of aging process. Marginal fit and fracture resistance values for all materials were found to be within clinically acceptable limits.

10.
Heliyon ; 10(2): e24205, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38293389

RESUMEN

Statement of the problem: Different CAD software programs used for designing crowns show variations in marginal and internal fit. Marginal and internal discrepancies may cause poorly fitting crowns. Purpose: The aim of this study was to compare the marginal and internal fit of single crown temporary restorations designed using three different CAD software programs. Materials and methods: Dentbird, Exocad and Inlab 20 were used to design temporary single crowns using the same cement gap. Three experimental groups (n = 10/group) were formed based on the CAD software used. Geomagic Control X three-dimensional analysis software was used to compare the marginal and internal fit among the groups. Measurements were obtained at nine different thickness points. IBM SPSS Statistics, version 22 was used for all statistical analyses. Results: Among the CAD software programs tested, Dentbird produced the best internal fit on the buccal surface and the best marginal fit on both buccal and mesial surfaces. Exocad achieved the best values on the distal surface for both internal and marginal fit, while Inlab showed the best values on the mesial surface for internal fit and on the palatal surface for marginal fit. Conclusions: The Dentbird CAD software program provided the most accurate fit values that closely matched the design. The marginal and internal fit oftemporary crowns may vary depending on the CAD software used.

11.
Odontology ; 112(1): 169-176, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37422770

RESUMEN

The aim of this study is to evaluate the effect of pre-ceramic soldering on the marginal and internal fit of 4-unit zirconia fixed dental prostheses (FPDs) that have two abutments and two pontics. 4-unit zirconia frameworks (Zirkonzahn ICE Translucent) (Z Group) and monolithic zirconia (Zirkonzahn Prettau) (M Group) FPDs were manufactured. Groups were divided into two groups (n = 10) control (ZC and MC) and soldering (ZS and MS). Samples of ZS and MS groups were cut into two pieces under cooling water and soldered with a bonding material (DCM Zircon HotBond). The marginal and internal fit of the restorations were measured from 36 points of each sample and cement space volume was calculated using reverse engineering software (Geomagic Design X). The mean and standard deviations were submitted to Generalized Linear Mixed Model (GLMM) analysis (α = 0.05). Statistical differences between groups before and after pre-ceramic soldering on point measurements were found. In total cement spacing measurements, a significant difference was found amongst all groups (P < 0.05). However, in premolars, a statistically significant difference was found between ZC and ZS groups and MC and MS groups (P < 0.05). All discrepancies after pre-ceramic soldering were found to be lower than before.


Asunto(s)
Porcelana Dental , Prótesis Dental , Porcelana Dental/química , Cerámica/química , Materiales Dentales/química , Circonio/química , Cementos Dentales , Cementos de Ionómero Vítreo , Adaptación Marginal Dental , Dentadura Parcial Fija , Diseño Asistido por Computadora
12.
BMC Oral Health ; 23(1): 965, 2023 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-38049754

RESUMEN

PURPOSE OF THE STUDY: The goal behind this study is to answer the question "In tooth-supported fixed partial dentures (FPDs), does the digital impression techniques compared to fabrications using conventional impression methods improve the marginal and internal fit? BACKGROUND: The incorporation of digital technology in the fabrication of fixed partial dentures (FPDs) has accelerated over the past decade. This study is directed at evaluating the marginal and internal fit of FPDs manufactured using digital approaches compared to conventional techniques. The need for updated data has encouraged this review. MATERIALS AND METHODS: An electronic search was conducted in PubMed, Scopus, Web of Science, and the Grey Database to identify relevant studies. The Modified Methodological Index for Non-Randomized Studies (MINORS) was used to assess the risk of bias in in vitro experiments. The key results of this meta-analysis were the standard mean differences (SMDs) and 95% confidence intervals (CI) of each main variance, marginal fit, and internal fit between the digital and conventional techniques. Additional analyses were performed to assess the significance of three subgroup parameters: method of digitalization, cement spacer thickness, and span length, and their influence on the fit of the FPDs. RESULTS: Based on predefined criteria, of the seven articles included in this systematic review, only five were selected for the quantitative data analysis. The marginal fit results were (P = 0.06; SMD: -1.88; 95% CI: - 3.88, 0.11) (P > 0.05) and the internal fit results were (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.10) (P < 0.05). Regarding the subgroup analyses, the method of digitalization subgroup results were (P = 0.35; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.80; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively. The span length results were (P = 0.10; SMD: -1.89; 95% CI: - 3.89, 0.11) for marginal fit and (P = 0.02; SMD: -0.80; 95% CI: - 1.49, - 0.11) for internal fit. The cement spacer thickness (P = 0.01; SMD: -1.89; 95% CI: - 3.89, 0.11) and (P = 0.04; SMD: -0.80; 95% CI: - 1.49, - 0.11) for marginal and internal fit, respectively. CONCLUSION: Tooth-retained fixed partial dentures FPDs produced by digital scanning and computer-aided design/computer-aided manufacturing (CAD/CAM) systems can significantly enhance the internal fit compared with those manufactured by traditional methods. Intraoral scanners can replace conventional impressions for the fabrication of FPDs because they minimize the operating time and reduce patient pain. Further clinical studies are required to obtain more conclusive results. SYSTEMATIC REVIEW REGISTRATION: This systematic review and meta-analysis was registered in the International Prospective Register of Systematic Reviews (PROSPERO), registration number CRD42021261397.


Asunto(s)
Adaptación Marginal Dental , Dentadura Parcial Fija , Humanos , Diseño Asistido por Computadora , Proyectos de Investigación , Diseño de Prótesis Dental
13.
BMC Oral Health ; 23(1): 967, 2023 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-38053146

RESUMEN

BACKGROUND: In-vitro data from a clinically well-known lithium disilicate ceramic reference was used to assess the expected performance of resin-based materials in implant dentistry. The purpose of the study was to compare the bond strength and marginal adaptation of nano-ceramic hybrid composite crowns cemented to stock cement-retained abutments to lithium disilicate crowns. METHODS: Twenty abutment analogs were embedded into auto-polymerizing acrylic resin blocks. The blocks were divided into 2 groups according to the restorative crown material. The 2 groups were divided as follows: Resin nano-ceramic group and lithium disilicate group. Abutment analogs in both groups were scanned using a laboratory scanner, and the restorations were designed, manufactured, and cemented with resin cement over the corresponding group. All samples were tested for marginal adaptation and bond strength after storage for 24 hours at 37 °C in 100% humidity. Data were collected, tabulated, and statistically analysed using the appropriate tests. Normality was checked using Shapiro Wilk test and Q-Q plots. Data were normally distributed. Variables were presented using mean, 95% Confidence Interval (CI) and standard deviation in addition to median and Inter Quartile Range (IQR). Differences between groups regarding debonding forces was assessed using independent t test. Two Way ANOVA was performed to assess the effect of material and bonding on marginal gap. All tests were two tailed and p value was set at < 0.05. RESULTS: Marginal gap and debonding force values were significantly different according to the type of material used (P < .05). Resin nano-ceramic crowns presented lower marginal gap values before (20.80 ± 8.87 µm) and after (52.11 ± 22.92 µm) bonding than lithium disilicate crowns. The debonding force value for resin nano-ceramic crowns (284.30 ± 26.44 N) was significantly higher than that for lithium disilicate crowns (253.30 ± 33.26 N). Adhesive failure mode was detected in all the specimens in both groups. CONCLUSIONS: The type of material used for implant-supported cement-retained crowns had a statistically significant effect on marginal adaptation and bond strength. Resin nano-ceramic implant-supported cement-retained crowns had better marginal adaptation and higher bond strength than those manufactured using lithium disilicate.


Asunto(s)
Coronas , Cementos Dentales , Humanos , Cementos de Ionómero Vítreo , Materiales Dentales , Cerámica , Cementos de Resina , Diseño Asistido por Computadora , Ensayo de Materiales
14.
Biomedicines ; 11(12)2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38137337

RESUMEN

Over the past two decades, dental ceramics have experienced rapid advances in science and technology, becoming the fastest-growing field of dental materials. This review emphasizes the significant impact of translucent zirconia in fixed prosthodontics, merging aesthetics with strength, and highlights its versatility from single crowns to complex bridgework facilitated by digital manufacturing advancements. The unique light-conducting properties of translucent zirconia offer a natural dental appearance, though with considerations regarding strength trade-offs compared to its traditional, opaque counterpart. The analysis extends to the mechanical attributes of the material, noting its commendable fracture resistance and durability, even under simulated physiological conditions. Various zirconia types (3Y-TZP, 4Y-TZP, 5Y-TZP) display a range of strengths influenced by factors like yttria content and manufacturing processes. The study also explores adhesive strategies, underlining the importance of surface treatments and modern adhesives in achieving long-lasting bonds. In the realm of implant-supported restorations, translucent zirconia stands out for its precision, reliability, and aesthetic adaptability, proving suitable for comprehensive dental restorations. Despite its established benefits, the review calls for ongoing research to further refine the material's properties and adhesive protocols and to solidify its applicability through long-term clinical evaluations, ensuring its sustainable future in dental restorative applications.

15.
BMC Oral Health ; 23(1): 880, 2023 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-37978507

RESUMEN

BACKGROUND: In clinical practice, control of the marginal fit of fixed dental prostheses is hindered by evaluation method, which needs to be further improved to increase its clinical applicability. This study aimed to quantitatively analyze the absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated by conventional and digital technologies using a digital measurement method based on the digital impression technology and open source software. METHODS: A digital workflow and the conventional impression combined with the lost-wax heat-pressed technique were adopted to separately fabricate 10 glass ceramic fixed dental prostheses. Three-dimensional data for the abutments, fixed dental prostheses, and fixed dental prostheses seated on the abutments, were obtained using a dental scanner. The two datasets were aligned using registration technology, specifically "multi-points registration" and "best fit alignment," by reverse engineering software. Subsequently, the three-dimensional seated fit between the fixed dental prostheses and abutments were reconstructed. The margin of the abutment and crown was extracted using edge-sharpening and other functional modules, and the absolute marginal discrepancy was measured by the distance between the margin of the abutment and crown. One-way analysis of variance was used to statistically analyze the measurement results. RESULTS: Using the digital measurement method, the mean value of absolute marginal discrepancy for fixed dental prostheses fabricated by the conventional method was 106.69 ± 6.46 µm, and that fabricated by the digital workflow was 102.55 ± 6.96 µm. The difference in the absolute marginal discrepancy of three-unit all-ceramic fixed dental prostheses fabricated using the two methods was not statistically significant (p > 0.05). CONCLUSIONS: The digital measurement method for absolute marginal discrepancy was preliminarily established based on open source software and applied in three-unit ceramic fixed dental prostheses. The absolute marginal discrepancy of three-unit ceramic fixed dental prostheses fabricated using digital technology was comparable to that of conventional technique.


Asunto(s)
Diseño de Prótesis Dental , Tecnología Digital , Humanos , Diseño de Prótesis Dental/métodos , Adaptación Marginal Dental , Diseño Asistido por Computadora , Cerámica , Coronas , Técnica de Impresión Dental
16.
J Indian Prosthodont Soc ; 23(4): 391-397, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37861617

RESUMEN

Aim: This study investigates the effectiveness of an innovative virtual tooth preparation workflow for the fabrication of dental crowns using cone-beam computed tomography (CBCT) and intraoral scanners (IOSs) with conventional workflow using extraoral/laboratory scanners. Settings and Design: This in vitro experimental study was conducted in the laboratory of a university in Chennai, India. The dental laboratory and research facilities at the institution were utilized for the fabrication of the temporary crowns and the data acquisition process. Materials and Methods: Institutional approval was obtained from the university. It was basically a comparison between the virtual prep technique using CBCT and IOS and the conventional digital technique using extra oral scanners (EOS) for temporary crown fabrication. The sample size was estimated using an effect size of 1.5004, assuming a normal distribution, a significance level of 0.05, and a power of 0.95 in G power software. Based on this calculation, an extracted second lower molar was used to fabricate 10 samples in each group. The samples were divided into three groups: the CBCT (Group 1), the IOS (Group 2), and laboratory scanner (Group 3 as control) groups. The vertical marginal gap of all the surfaces of the crown was evaluated using a scanning electron microscope. Statistical Analysis Used: Data were analyzed using one-way ANOVA using the SPSS software version 26.0, IBM, Armonk, NY, USA. Results: Acceptable marginal discrepancy values were obtained in all three groups. There was no significant difference in the marginal discrepancy recorded (P = 0.113). Conclusion: Virtual tooth preparation using CBCT and IOSs can be used as an alternative to the conventional workflow for provisional crown and bridge fabrication.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Humanos , Flujo de Trabajo , Diseño de Prótesis Dental/métodos , Adaptación Marginal Dental , India
17.
Cureus ; 15(9): e44638, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37799216

RESUMEN

This systematic review aimed to synthesize and analyze a collection of studies focused on comparing conventional veneers (CVs) and minimal or no-preparation veneers (MPVs) within the domain of prosthodontics. The review sought to explore various attributes, techniques, outcomes, and considerations associated with these two approaches. The key aspects investigated included esthetics, longevity, periodontal health, patient satisfaction, structural influences such as microleakage and marginal fit, cement thickness, and color stability. A systematic literature search was conducted to identify relevant studies published up to the present date. Studies meeting specific inclusion and exclusion criteria were selected for review. Studies pertaining to various methodologies were identified initially as part of the strategy and bias assessment was performed to determine the credibility of their assessments before inclusion in this review. Four comparative assessments gleaned from the selected studies provided a comprehensive overview of the strengths and limitations associated with CVs and MPVs. MPVs demonstrated advantages such as enhanced survival rates and extended mean success periods, implying their potential as viable long-term restorative options. Meticulous patient management and optimal preparation techniques emerged as crucial factors influencing successful outcomes. Structural attributes, including microleakage and marginal fit, varied depending on the preparation techniques employed. Moreover, considerations related to color changes in veneers underscored the intricate interplay between material properties and fabrication methods. The insights underscore the significance of patient-centric care, precision preparation methodologies, and material choices in guiding successful outcomes. However, the diverse methodologies and constraints of certain studies warrant careful interpretation. This study accentuates the potential for future research directions, interdisciplinary collaboration, and the advancement of evidence-based practices within veneer dentistry.

18.
Indian J Dent Res ; 34(2): 199-203, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37787213

RESUMEN

Introduction: The marginal fit of any dental restoration is vital to its long-term success. Lack of adequate fit is potentially detrimental to both the tooth and the supporting periodontal tissues. The purpose of this study was to evaluate the marginal fit of monolithic zirconia, monolithic lithium disilicate and monolithic metal crowns and compare the three groups. Methods: The study was conducted by fabricating ten samples for each group, total of 30 samples. A premolar stainless steel die was used to standardize the preparation. PVS putty material was used to make impressions of the model and was poured using type IV die stone. The samples were all fabricated using CAD-CAM. The marginal gap was measured by SEM, and the results were analysed using SPSS software. Results: The mean marginal gap of zirconia, metal and lithium disilicate crowns was 79.49 µm, 46.83 µm and 70.79 µm, respectively. Discussion: The metal group showed the lowest marginal gap among the groups. This difference in marginal fit is due to the sintering process where the organic binders in soft metal burn out and the metallic powder particles are being sintered (caked) without creating a fused phase. Clinical Significance: Marginal fit plays a very important role in the long-term success of a crown. Discrepancy in marginal fit results in food and plaque accumulation causing caries and periodontal breakdown, eventuating the failure of the restoration. A perfect marginal fit would enhance the longevity of any indirect restoration. Knowledge about which indirect restoration has the best marginal fit is critical.


Asunto(s)
Adaptación Marginal Dental , Diseño de Prótesis Dental , Diseño de Prótesis Dental/métodos , Porcelana Dental , Coronas , Diseño Asistido por Computadora , Cerámica
19.
J Clin Med ; 12(15)2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37568450

RESUMEN

BACKGROUND: Different methods are used for the analysis of marginal and internal fit of partial crowns, but not all of them are applicable for in vivo studies. The aim of this review is to search the available methods, described in the current literature, to assess marginal and internal fit in partial crowns. METHODS: an electronic search was performed on Pubmed and Web of Science databases to find studies published from 1 January 2017 up to 2 March 2023, following PRISMA guidelines and Cochrane handbook for systematic reviews. The search strategy applied was: "(marginal) AND (fit OR gap OR adaptation OR discrepancy) AND (inlay OR onlay OR partial crown)". In vitro studies which evaluated marginal and internal fit on CAD CAM or 3D printed partial crowns were included in this review. Quality of the studies was assessed by using Quality Assessment Tool For In Vitro Studies (QUIN tool). RESULTS: 22 studies were included. Among conventional methods, direct view with microscope, indirect view on resin replicas, and silicone replica technique (SRT) were used. Considering new digital methods, micro-CT, SRT 3D and triple scan technique (TST) were applied. CONCLUSIONS: Among 2D methods, direct view technique is the most used marginal fit analysis. For a more comprehensive evaluation, a 3D digital analysis is suggested. SRT and indirect view are the only 2D methods available for in vivo analysis. A protocol for the application of TST for assessment in vivo is now available, but no studies are reported in literature yet.

20.
Int J Comput Dent ; 0(0): 0, 2023 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-37477084

RESUMEN

AIM: The purpose of this systematic review and meta-analysis is to evaluate the marginal adaptation of single unit full coverage lithium disilicate fixed dental restorations fabricated with the conventional heat pressed technique and the digital CAD/CAM workflow. MATERIALS AND METHODS: This study is according to the Preferred Reporting Items for Systematic Reviews and Meta- Analyses (PRISMA) statement. study research was conducted in MEDLINE via PubMed and Cochrane Library databases together with a hand search of studies published until June 2022. The search terms were combining suitable Medical Subject Headings (MeSH terms) together with free text words in single or multiple conjunctions. A modified methodological index was used to assess the risk of bias of the included studies. A random effect model was applied to pool the effect estimates, and further assessment of the heterogeneity across studies using the Q test and the I2 metric was conducted. All statistical analyses were performed using Rstudio software, version 4.1.2, using the "meta" package. RESULTS: The electronic search and hand search identified 51 articles. Eighteen met the inclusion criteria and were included in the systematic review, 17 of which were in vitro and only one was an in vivo study. However, 17 of the initial 18 could be included in the meta-analysis, due to lack of statistical data in one of the in vitro studies. Statistical analyses were conducted by using the Rstudio software program. Meta-analysis was performed with the random effects model (α=.05). No statistical difference was found between the two fabrication methods (p-value=0.49). CONCLUSIONS: Although the mean marginal adaptation of lithium disilicate single crowns was found to be better with the heat-pressed technique, there was no statistical significance with the CAD/CAM fabricated restorations and both resulted in a clinically acceptable result. Nonetheless, more clinical studies are needed for safer conclusions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA