Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.067
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38817688

RESUMEN

Gossypiboma is an extremely rare adverse event occurring post-surgery, where surgical gauze is left within the body. If aseptically retained, it can lead to the formation of granulation tissue through chronic inflammation and adhesion with surrounding tissues, potentially persisting asymptomatically for many years. While diagnosis of this condition has been reported through various imaging modalities such as abdominal ultrasound and computed tomography, cases not presenting with typical findings are difficult for preoperative diagnosis, and instances where it is discovered postoperatively exist. Particularly when in contact with the gastrointestinal tract within the abdominal cavity, differentiation from submucosal tumors of the digestive tract becomes problematic. This report describes the imaging characteristics of endoscopic ultrasound and the usefulness of endoscopic ultrasound-fine-needle-aspiration for tissue diagnosis in the preoperative diagnosis of intra-abdominal gossypiboma.

2.
Cureus ; 16(7): e63582, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39087177

RESUMEN

Background The fabrication of titanium carbide (Ti3C2)-cobalt sulfide (Co3S4)-based biosensors with high sensitivity and selectivity can change the biosensor manufacturing industry completely. Molecular and clinical diagnostics, disease progression monitoring, and drug discovery could utilize these sensors for early biomarker detection. MXene (Ti3C2) is a two-dimensional material with exceptional electrical conductivity, hydrophilicity, great thermal stability, large interlayer spacing, and a high surface area. Ti3C2's remarkable characteristics make it well-suited for biomolecule immobilization and target analyte detection. Co3S4 is a transition metal chalcogenide that has shown great potential in biosensors. Co3S4 nanoparticles (NPs) can potentially enhance Ti3C2 electrocatalytic activity, particularly in amino acid detection. L-arginine is a semi-essential amino acid, and the body frequently uses it to support healthy circulation and plays a crucial role in protein synthesis. We fabricated the Ti3C2-Co3S4 biosensor for L-arginine detection. Aim  This study aims to synthesize and apply Ti3C2-Co3S4 nanocomposites in amino acid biosensing. Materials and methods The Ti3C2 nanosheets were synthesized by the selective removal of an aluminum (Al) layer from the precursor (Ti3AlC2) using hydrofluoric acid (HF). The resulting mixture serves as an etchant, especially targeting the Al layers on Ti3AlC2 while protecting the desired MXene layers at room temperature. Cobalt nitrate hexahydrate was dissolved in deionized water. Sodium hydroxide was added to the cobalt solution and stirred. Thioacetamide was added to the above solution and stirred (Solution B). A mixture of Solution A and Solution B was stirred for 30 minutes. The mixture is transferred to a hydrothermal reactor and maintained at a temperature of 180°C for 12 hours. Once the reaction completes, we cool the resultant mixture to room temperature and then filter it using the washing technique. The sample underwent a 12-hour drying process at 80°C.  Results  This study investigated the use of a biosensor that employed Ti3C2-Co3S4 NPs to detect the concentration of L-arginine. The X-ray diffraction (XRD) shows clear and distinct peaks, which means that the synthesized Ti3C2-Co3S4 nanostructures have a crystalline structure. Scanning electron microscopy (SEM) analysis revealed that the sheetlike structure of synthesized Ti3C2-Co3S4 nanostructures revealed the crystalline morphology. The results of this study show that the Ti3C2-Co3S4 NP-based biosensor can be used to detect L-arginine in a sensitive and selective way. Conclusion  This study investigated the synthesis of Ti3C2-Co3S4 NPs and their ability to detect L-arginine levels and show a distinct correlation between the L-arginine concentration and the fluorescence intensity, demonstrating the biosensor's effectiveness in detecting L-arginine levels.

3.
Aust Endod J ; 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-38946230

RESUMEN

The aim was to analyse the influence of an apical ledge on root canal disinfection. Forty-four single-rooted teeth were micro-CT scanned and inoculated with Enterococcus faecalis. In Group S shaping was performed with ProTaper Next (PTN) up to X3 at working length (WL). In Group L an apical ledge was created with K-Files #40 and shaping completed up to PTN X3. NaOCl 5% and EDTA 10% irrigant solutions were alternated. Confocal laser scanning microscope (CLSM) and viability staining were used to analyse the proportions of dead (red) and live (green) bacteria and penetration ability inside dentinal tubules. Data were analysed with the Mann-Whitney test with Bonferroni correction (p < 0.05). In Group L the amount of red fluorescence resulted significantly lower, and penetration ability was decreased in the apical and middle portion (p < 0.05). The presence of an apical ledge may negatively influence the disinfection both in the apical and middle third.

4.
FASEB Bioadv ; 6(7): 189-199, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38974114

RESUMEN

Autophagy, an intracellular self-degradation process, is governed by a complex interplay of signaling pathways and interactions between proteins and organelles. Its fundamental purpose is to efficiently clear and recycle cellular components that are damaged or redundant. Central to this process are autophagic vesicles, specialized structures that encapsulate targeted cellular elements, playing a pivotal role in autophagy. Despite growing interest in the molecular components of autophagic machinery and their regulatory mechanisms, capturing the detailed ultrastructural dynamics of autophagosome formation continues to present significant challenges. However, recent advancements in microscopy, particularly in electron microscopy, have begun to illuminate the dynamic regulatory processes underpinning autophagy. This review endeavors to provide an exhaustive overview of contemporary research on the ultrastructure of autophagic processes. By synthesizing observations from diverse technological methodologies, this review seeks to deepen our understanding of the genesis of autophagic vesicles, their membrane origins, and the dynamic alterations that transpire during the autophagy process. The aim is to bridge gaps in current knowledge and foster a more comprehensive comprehension of this crucial cellular mechanism.

5.
OTO Open ; 8(3): e162, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38974181

RESUMEN

Objective: Evaluate ergonomic differences of various modalities for performing middle ear surgery. Study Design: Observational study. Setting: Two academic tertiary care centers. Methods: Attending physicians and residents performing middle ear surgery were photographed intraoperatively. Intraoperative photographs were analyzed using the validated Rapid Upper Limb Assessment (RULA) tool to measure musculoskeletal disease (MSD) risk. Descriptive statistics and significance testing were used to characterize and compare ergonomic differences between surgical modalities. Multivariable ordinal regression was performed to assess factors associated with increased MSD risk, as determined by the final RULA score. Results: Most of our 110 intraoperative photos featured attendings (82.7%) performing combined middle ear surgery and mastoidectomy (60.0%). Body angles and the final RULA score varied significantly among modalities. On subset analysis, microscopic surgery exhibited significantly worse wrist, trunk, and neck angles compared to endoscopic and exoscopic surgery. Exoscopic surgery had significantly lower final RULA scores than both endoscopic and microscopic surgery, indicating significantly lower MSD risk. Microscopic and endoscopic surgery final scores did not vary significantly. In a multivariable ordinal regression of factors associated with increased RULA score, exoscopic surgery had statistically significantly less ergonomic risk relative to microscopic surgery (odds ratio = 0.12, 95% confidence interval = [0.03-0.43]). Conclusion: Exoscopic, endoscopic, and microscopic surgery all featured low ergonomic risk, although exoscopic middle ear surgery demonstrated the lowest risk profile among studied surgical modalities. This demonstrates the importance of using each modality in combination with other ergonomic interventions to provide meaningful musculoskeletal benefits.

6.
Sci Rep ; 14(1): 16566, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39019931

RESUMEN

Biologically mediated synthesis of nanomaterials has emerged as an ecologically benign and biocompatible approach. Our study explores enzymatic synthesis, utilizing α-amylase to synthesize ZnO nanoflowers (ZnO-NFs). X-ray diffraction and energy-dispersive X-ray spectroscopy revealed crystal structure and elemental composition. Dynamic light scattering analysis indicates that ZnO-NFs possess a size of 101 nm. Transmission electron microscopy showed a star-shaped morphology of ZnO-NFs with petal-like structures. ZnO-NFs exhibit potent photocatalytic properties, degrading 90% eosin, 87% methylene blue, and 81% reactive red dyes under UV light, with kinetics fitting the Langmuir-Hinshelwood pseudo-first-order rate law. The impact of pH and interfering substances on dye degradation was explored. ZnO-NFs display efficient bacteriocidal activity against different Gram-positive and negative strains, antibiofilm potential (especially with P. aeruginosa), and hemocompatibility up to 600 ppm, suggesting versatile potential in healthcare and environmental remediation applications.


Asunto(s)
Tecnología Química Verde , Óxido de Zinc , alfa-Amilasas , Óxido de Zinc/química , Óxido de Zinc/farmacología , alfa-Amilasas/metabolismo , alfa-Amilasas/antagonistas & inhibidores , Tecnología Química Verde/métodos , Nanoestructuras/química , Antibacterianos/farmacología , Antibacterianos/química , Biopelículas/efectos de los fármacos , Antiinfecciosos/farmacología , Antiinfecciosos/química , Pruebas de Sensibilidad Microbiana , Biomimética/métodos , Humanos
7.
PeerJ ; 12: e17717, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39026539

RESUMEN

Background: Different methods for removing dental carious lesions exist, including conventional rotary caries removal and new advanced technology like polymer-based burs, chemomechanical agents, air abrasion, and laser. Objectives: This study shows the differences in features of dentin (smear layer, patency of dentinal tubules, surface irregularities, intertubular micro porosities, and exposed dentinal tubules) among different types of caries removal techniques. Materials and Methods: An in vitro study was done on 60 primary molars with occlusal class I active caries. Teeth were divided into three groups according to a method of caries removal (G1: chemomechanical, G2: mechanical with a smart bur, and G3: air-abrasion). After complete caries excavation, the teeth were examined under a scanning electronic microscope (SEM) with the power of magnification 4,000x and 8,000x to show the morphological dentinal features with SEM microphotographs. Data obtained was analyzed using the SPSS program where Fisher exact, Kruskal-Wallis and multiple Wilcoxon sum rank tests were used. The level of significance is when the p-value is less than 0.05. Results: Generally, SEM showed the highest ratio of score 1 of smear layer presence, surface irregularities, and microporosity in all groups in both magnifications. The patency of tubules showed the highest ratio of score 1 in G1, scores 2 in both G2 and G3 in magnification 4,000x, while 8,000x there was the highest ratio of its score 1 in G1 and G2 while the G3 has score 2 as the highest score. The exposed dentinal tubules showed the highest ratio in G1 in score 3, in G2 in score 2, and in G3 in score 1 in magnification 4,000x, while 8,000x there was the highest ratio of its score 2 in both G1 and G3 while the G3 has highest score 1. The study with magnification 4,000x showed a significant difference (S) among three groups in exposed dentinal tubules with a p-value (0.012), and there was S between chemomechanical and smart, chemomechanical and air-abrasions groups with a p-value (0.041, 0.001 subsequentially). Other dentin features showed non-significant differences (NS) among or between groups in both magnifications (4,000x, 8,000x). Conclusions: All groups were effective in removing caries and can successfully treat young, scared or stressed patients. All methods of caries removal produce clinically parametric changes in the residual dentin.


Asunto(s)
Caries Dental , Dentina , Microscopía Electrónica de Rastreo , Diente Molar , Caries Dental/terapia , Caries Dental/patología , Humanos , Diente Molar/cirugía , Técnicas In Vitro , Abrasión Dental por Aire/métodos , Preparación de la Cavidad Dental/métodos , Preparación de la Cavidad Dental/instrumentación , Propiedades de Superficie
8.
Talanta ; 278: 126537, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38996561

RESUMEN

Imaging live cells under stable culture conditions is essential to investigate cell physiological activities and proliferation. To achieve this goal, typically, a specialized incubation chamber that creates desired culture conditions needs to be incorporated into a microscopy system to perform cell monitoring. However, such imaging systems are generally large and costly, hampering their wide applications. Recent advances in the field of miniaturized microscopy systems have enabled incubator cell monitoring, providing a hospitable environment for live cells. Although these systems are more cost-effective, they are usually limited in imaging modalities and spatial temporal resolution. Here, we present a dual-mode, image-enhanced, miniaturized microscopy system (termed MiniCube) for direct monitoring of live cells inside incubators. MiniCube enables both bright field imaging and fluorescence imaging with single-cell spatial resolution and sub-second temporal resolution. Moreover, this system can also perform cell monitoring inside the incubator with tunable time scales ranging from a few seconds to days. Meanwhile, automatic cell segmentation and image enhancement are realized by the proposed data analysis pipeline of this system, and the signal-to-noise ratio (SNR) of acquired data is significantly improved using a deep learning based image denoising algorithm. Image data can be acquired with 5 times lower light exposure while maintaining comparable SNR. The versatility of this miniaturized microscopy system lends itself to various applications in biology studies, providing a practical platform and method for studying live cell dynamics within the incubator.

9.
Chemosphere ; 363: 142882, 2024 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-39025315

RESUMEN

Efficient separation of actinide elements from molten salts employed in pyroprocessing can significantly diminish the radiological hazards and oversight duration associated with spent nuclear fuel storage. The lanthanum content of waste salts is very high compared to actinides, leading to the co-electrodeposition of both groups of elements for conventional electrochemical techniques. Due to the difficulty in separating the two groups of elements, the feasibility of the density-based separation using liquid bismuth and intermetallics was explored. Hafnium was used as a stand-in for actinide elements with physical properties mirroring those of actinide-laden Bi-Hf intermetallics. Conversely, cerium was chosen to represent lanthanides. This study delved into the formation and spatial distribution of bismuth intermetallics under varying concentration ratios and cooling durations. Comprehensive characterization was achieved using scanning electron microscopy and energy-dispersive spectrometry. The analysis showed that Bi-Ce particles were formed and distributed in the upper layer of the Bi ingot, and Bi-(Ce, Hf) particles containing both Ce and Hf in the lower layer. The findings underscore the viability of density-based separation while highlighting the intricacies related to intermetallic coprecipitation. Continued investigations are essential to fully harness the potential of density-based separation.

10.
Cureus ; 16(6): e63076, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39055446

RESUMEN

The morphological variations in roots and root canals vary greatly in multi-rooted teeth making it a challenge for accurate diagnosis and effective endodontic therapy. In addition to using technology appropriately, this article highlights how important it is to have a complete understanding of root canal morphology. With the assistance of cone-beam computed tomography (CBCT) images and a dental operating microscope (DOM), successful endodontic treatment was performed on a single-rooted maxillary first molar with Vertucci's type II canal configuration. CBCT and DOM proved to be valuable tools for the effective diagnosis and management of this atypical morphology.

11.
Sci Rep ; 14(1): 17027, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39043857

RESUMEN

This study aims to compare the roughness between the central and edge points on the porcelain sectional surface of porcelain fused to Co-Cr alloy endocrowns. Utilizing anatomical data from average molar dimensions, a simplified model for the endocrowns was created. Eight porcelain fused to Co-Cr alloy endocrowns were fabricated with an edge thickness of 0.3 mm. Following casting, firing, cutting, and polishing procedures, the roughness on porcelain sectional surface at both the central and edge points of the inner crown was assessed using an atomic force microscope (AFM). The roughness measurement (Sq value) for the central point on porcelain sectional surface was (10.46 ± 3.37 nm), and for the edge point, it was (10.50 ± 1.99 nm). There was no statistically significant distinction between the central and edge points in terms of roughness. Despite the uneven thickness of the inner crown in porcelain fused to Co-Cr alloy endocrowns, it was observed that this disparity had negligible impact on the internal microstructure of the porcelain. Therefore, its application in dental clinical settings could be deemed viable.

12.
Sci Rep ; 14(1): 17105, 2024 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-39048652

RESUMEN

To explore the effect and mechanism of coir fiber on the performance of foamed concrete, the flexural performance test, pore characteristics and microstructure test of coir fiber foamed concrete with different content were carried out. First, Image-Pro Plus (image processing software) was used to study the pore morphology, porosity, average pore diameter, and pore roundness of CFFC with various fibers dosage (0, 0.5%, 1.0%, 1.5%, 2.0%, 2.5%) by binarization processing method. Then, a total of eighteen specimens, divided into six groups, were used to investigate the effect of CF dosage on flexural strength, toughness, energy absorption, and failure patterns of FC through a three-point flexural test. Furthermore, the microscopic properties of coir fiber foamed concrete (CFFC) were observed by scanning electron microscope (SEM) and energy dispersive X-ray detector (XRD) to explain the influence mechanism of CF on FC flexural properties. According to the research, CF can affect the pore characteristics of CFFC and improve its flexural performance. When CF content is 1.5-2.0%, the porosity, diameter and roundness of CFFC have lower values of 68.6%, 1.96 mm and 1.29. After the fiber dosage reaches 1.5%, the CFFC failure mode changed to plastic damage, the flexural strength increased from 0.33 to 0.73 MPa, and the toughness energy absorption value was increased from 0.05 to 1.4 J. The optimum dosage of coir fiber is 2.0% for improving the flexural mechanical properties of FC. CF affects the process of hydration reaction of CFFC, but does not change the type of hydration product. However, the flexural performance of FC would decrease with excessive dosage of CF (> 2.0%) due to accelerating the formation of Ca(OH)2. CFFC can solve problems such as brittleness and easy cracking existing in traditional foamed concrete, and it can be used in the field of pavement engineering, foundation backfill and lightweight wall structure with CF dosage of 15-2.0%.

13.
Pharm Dev Technol ; : 1-12, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38965754

RESUMEN

Depression, the second biggest cause of disability worldwide, is widespread. Many antidepressant medications, including Desvenlafaxine Succinate (D.V.S.), function by elevating neurotransmitter levels at the synapse through the inhibition of reabsorption by neurons. However, the effectiveness of these treatments is often limited by their inability to reach the brain using conventional administration methods. Bilosome-stabilized nanovesicles containing bile salts have drawn much interest because of their adaptability and versatility in various applications. This study aimed to address this issue by formulating intranasal bilosomes incorporated into a mucoadhesive in situ gel to deliver D.V.S. directly to the brain for depression treatment. The desvenlafaxine-loaded bilosomes were developed using a thin film hydration method based on the l-optimal design. They were intended to provide a more convenient route of administration for antidepressants, enhancing bioavailability and brain targeting through intranasal delivery. The study assessed the optimized bilosomes for particle size (311.21 ± 0.42 nm), Zeta potential (-37.35 ± 0.43)and encapsulation efficiency (99.53 ± 0.41%) and further evaluated them in ex vivo and in vivo pharmacokinetics studies. Pharmacokinetic data reveal enhanced brain uptake compared to a free drug. A statistically optimized bilosome formulation was determined. The intranasal administration of mucoadhesive in situ gel containing desvenlafaxine succinate-loaded bilosomes facilitated direct nose-to-brain drug delivery, improving brain bioavailability.

14.
Front Surg ; 11: 1418679, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38983589

RESUMEN

Objective: The development of surgical microscope-associated cameras has given rise to a new operating style embodied by hybrid microsurgical and exoscopic operative systems. These platforms utilize specialized camera systems to visualize cranial neuroanatomy at various depths. Our study aims to understand how different camera settings in a novel hybrid exoscope system influence image quality in the context of neurosurgical procedures. Methods: We built an image database using captured cadaveric dissection images obtained with a prototype version of a hybrid (microsurgical/exoscopic) operative platform. We performed comprehensive 4K-resolution image capture using 76 camera settings across three magnification levels and two working distances. Computer algorithms such as structural similarity (SSIM) and mean squared error (MSE) were used to measure image distortion across different camera settings. We utilized a Laplacian filter to compute the overall sharpness of the acquired images. Additionally, a monocular depth estimation deep learning model was used to examine the image's capability to visualize the depth of deeper structures accurately. Results: A total of 1,368 high-resolution pictures were captured. The SSIM index ranged from 0.63 to 0.85. The MSE was nearly zero for all image batches. It was determined that the exoscope could accurately detect both the sharpness and depth based on the Laplacian filter and depth maps, respectively. Our findings demonstrate that users can utilize the full range of camera settings available on the exoscope, including adjustments to aperture, color saturation, contrast, sharpness, and brilliance, without introducing significant image distortions relative to the standard mode. Conclusion: The evolution of the camera incorporated into a surgical microscope enables exoscopic visualization during cranial base surgery. Our result should encourage surgeons to take full advantage of the exoscope's extensive range of camera settings to match their personal preferences or specific clinical requirements of the surgical scenario. This places the exoscope as an invaluable asset in contemporary surgical practice, merging high-definition imaging with ergonomic design and adaptable operability.

15.
Sci Rep ; 14(1): 16424, 2024 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-39013935

RESUMEN

Lately, children's daily consumption of some products, such as cereals and candies, has been rising, which provides a compelling rationale for determining any metallic substances that may be present. Monitoring the concentration of certain metals, like nickel, in these products is necessary due to medical issues in humans when consumed regularly. So, in this work, a novel and highly selective carbon paste as a Ni(II) ion-selective sensor was prepared and investigated using ceramic magnesium aluminum spinel nanoparticles as the ionophore and tritolyl phosphate (TOCP) as a plasticizer. A modified co-precipitation method was used to synthesize the spinel nanoparticles. X-ray diffraction, scanning electron microscope with EDAX, transmission electron microscope, and BET surface area were used to determine the phase composition, microstructure, pores size, particle size, and surface area of the synthesized nanoparticles. The spinel nanoparticle was found to have a nano crystallite size with a cubic crystal system, a particle size ranging from 17.2 to 51.52 nm, mesoporous nature (average pore size = 8.72 nm), and a large surface area (61.75 m2/g). The composition ratio of graphite carbon as a base: TOCP as binder: spinal as ionophore was 67.3:30.0:2.7 (wt%) based on potentiometric detections over concentrations from 5.0 × 10-8 to 1.0 × 10-2 mol L-1 with LOD of 5.0 × 10-8 mol L-1. A measurement of 29.22 ± 0.12 mV decade-1 over pH 2.0-7.0 was made for the Nernstian slope. This sensor demonstrated good repeatability over nine weeks and a rapid response of 8 s. A good selectivity was shown for Ni(II) ions across many interferents, tri-, di-, and monovalent cations. The Ni(II) content in spiked real samples, including cocaine, sweets, coca, chocolate, carbonated drinks, cereals, and packages, were measured. The results obtained indicated no significant difference between the proposed potentiometric method and the officially reported ICP method according to the F- and t-test data. In addition to utilizing ANOVA statistical analysis, validation procedures have been implemented, and the results exceed the ICP-MS methodology.


Asunto(s)
Níquel , Níquel/análisis , Níquel/química , Humanos , Niño , Óxido de Magnesio/química , Técnicas Electroquímicas/métodos , Óxido de Aluminio/química , Nanopartículas/química , Magnesio/química , Magnesio/análisis , Iones/análisis , Difracción de Rayos X , Ionóforos/química
16.
J Biomed Opt ; 29(9): 093505, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39050615

RESUMEN

Significance: Hyperspectral imaging (HSI) is an emerging imaging modality for oncological applications and can improve cancer detection with digital pathology. Aim: The study aims to highlight the increased accuracy and sensitivity of detecting the margin of thyroid carcinoma in hematoxylin and eosin (H&E)-stained histological slides using HSI and data augmentation methods. Approach: Using an automated microscopic imaging system, we captured 2599 hyperspectral images from 65 H&E-stained human thyroid slides. Images were then preprocessed into 153,906 image patches of dimension 250 × 250 × 84 pixels . We modified the TimeSformer network architecture, which used alternating spectral attention and spatial attention layers. We implemented several data augmentation methods for HSI based on the RandAugment algorithm. We compared the performances of TimeSformer on HSI against the performances of pretrained ConvNext and pretrained vision transformers (ViT) networks on red, green, and blue (RGB) images. Finally, we applied attention unrolling techniques on the trained TimeSformer network to identify the biological features to which the network paid attention. Results: In the testing dataset, TimeSformer achieved an accuracy of 90.87%, a weighted F 1 score of 89.79%, a sensitivity of 91.50%, and an area under the receiving operator characteristic curve (AU-ROC) score of 97.04%. Additionally, TimeSformer produced thyroid carcinoma tumor margins with an average Jaccard score of 0.76 mm. Without data augmentation, TimeSformer achieved an accuracy of 88.23%, a weighted F 1 score of 86.46%, a sensitivity of 85.53%, and an AU-ROC score of 94.94%. In comparison, the ViT network achieved an 89.98% accuracy, an 88.14% weighted F 1 score, an 84.77% sensitivity, and a 96.17% AU-ROC. Our visualization results showed that the network paid attention to biological features. Conclusions: The TimeSformer model trained with hyperspectral histological data consistently outperformed conventional RGB-based models, highlighting the superiority of HSI in this context. Our proposed augmentation methods improved the accuracy, the F 1 score, and the sensitivity score.


Asunto(s)
Imágenes Hiperespectrales , Neoplasias de la Tiroides , Humanos , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Imágenes Hiperespectrales/métodos , Algoritmos , Microscopía/métodos , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/patología , Procesamiento de Imagen Asistido por Computador/métodos , Redes Neurales de la Computación , Interpretación de Imagen Asistida por Computador/métodos
17.
Materials (Basel) ; 17(14)2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39063832

RESUMEN

In this study, we quantitatively investigate the impact of 1.4 wt.% chromium and 1.4 wt.% molybdenum additions on pearlitic microstructure characteristics in 1 wt.% carbon steels. The study was carried out using a combination of experimental methods and phase field simulations. We utilized MatCalc v5.51 and JMatPro v12 to predict transformation behaviors, and electron microscopy for microstructural examination, focusing on pearlite morphology under varying thermal conditions. Phase field simulations were carried out using MICRESS v7.2 software and, informed by thermodynamic data from MatCalc v5.51 and the literature, were conducted to replicate pearlite formation, demonstrating a good agreement with the experimental observations. In this work, we introduced a semi-automatic reliable microstructural analysis method, quantifying features like lamella dimensions and spacing through image processing by Fiji ImageJ v1.54f. The introduction of Cr resulted in longer, thinner, and more homogeneously distributed cementite lamellae, while Mo led to shorter, thicker lamellae. Phase field simulations accurately predicted these trends and showed that alloying with Cr or Mo increases the density and circularity of the lamellae. Our results demonstrate that Cr stabilizes pearlite formation, promoting a uniform microstructure, whereas Mo affects the morphology without enhancing homogeneity. The phase field model, validated by experimental data, provides insights into the morphological changes induced by these alloying elements, supporting the optimization of steel processing conditions.

18.
Micromachines (Basel) ; 15(7)2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39064439

RESUMEN

Fluorescence microscopic images of cells contain a large number of morphological features that are used as an unbiased source of quantitative information about cell status, through which researchers can extract quantitative information about cells and study the biological phenomena of cells through statistical and analytical analysis. As an important research object of phenotypic analysis, images have a great influence on the research results. Saturation artifacts present in the image result in a loss of grayscale information that does not reveal the true value of fluorescence intensity. From the perspective of data post-processing, we propose a two-stage cell image recovery model based on a generative adversarial network to solve the problem of phenotypic feature loss caused by saturation artifacts. The model is capable of restoring large areas of missing phenotypic features. In the experiment, we adopt the strategy of progressive restoration to improve the robustness of the training effect and add the contextual attention structure to enhance the stability of the restoration effect. We hope to use deep learning methods to mitigate the effects of saturation artifacts to reveal how chemical, genetic, and environmental factors affect cell state, providing an effective tool for studying the field of biological variability and improving image quality in analysis.

19.
Artículo en Inglés | MEDLINE | ID: mdl-39017782

RESUMEN

This chapter is intended to provide a brief overview of the optics of surgical microscopes and rigid endoscopes, with the aim of providing the reader with the principles dictating the nature of surgical visualization when either of the visual control systems is used. It is not by any means geared toward elaborating on the detailed optical physics of these systems, which is beyond the scope and objective of this chapter.


Asunto(s)
Microscopía , Humanos , Microscopía/instrumentación , Microscopía/métodos , Procedimientos Neuroquirúrgicos/instrumentación , Procedimientos Neuroquirúrgicos/métodos , Microcirugia/instrumentación , Microcirugia/métodos , Endoscopios , Neuroendoscopios
20.
HardwareX ; 19: e00545, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39006472

RESUMEN

The development of a compact and affordable fluorescence microscope can be a formidable challenge for growing needs in on-site testing and detection of fluorescent labeled biological systems, especially for those who specialize in biology rather than in engineering. In response to such a situation, we present an open-source miniature fluorescence microscope using Raspberry Pi. Our fluorescence microscope, with dimensions of 19.2 × 13.6 × 8.2 cm3 (including the display, computer, light-blocking case, and other operational requirements), not only offers cost-effectiveness (costing less than $500) but is also highly customizable to meet specific application needs. The 12.3-megapixel Raspberry Pi HQ Camera captures high-resolution imagery, while the equipped wide-angle lens provides a field of view measuring 21 × 15 mm2. The integrated wireless LAN in the Raspberry Pi, along with software-controllable high-powered fluorescence LEDs, holds potential for a wide range of applications. This open-source fluorescence microscope offers biohybrid sensor developers a versatile tool to streamline unfamiliar mechanical design tasks and open new opportunities for on-site fluorescence detections.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA