Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Intervalo de año de publicación
1.
Clinics ; Clinics;73: e261, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-890756

RESUMEN

Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 studies were found in the search, among which 4 randomized studies were selected for inclusion in the analysis. A total of 462 patients were evaluated (233: 25G needle/229: 22G needle). The diagnostic sensitivity was 93% for the 25G needle and 91% for the 22G needle. The specificity of the 25G needle was 87%, and that of the 22G needle was 83%. The positive likelihood ratio was 4.57 for the 25G needle and 4.26 for the 22G needle. The area under the sROC curve for the 25G needle was 0.9705, and it was 0.9795 for the 22G needle, with no statistically significant difference between them (p=0.497). Based on randomized studies, this meta-analysis did not demonstrate a significant difference between the 22G and 25G needles used during EUS-FNA in the diagnosis of solid pancreatic lesions.


Asunto(s)
Humanos , Páncreas/patología , Neoplasias Pancreáticas/patología , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/instrumentación , Agujas/normas , Neoplasias Pancreáticas/diagnóstico por imagen , Funciones de Verosimilitud , Ensayos Clínicos Controlados Aleatorios como Asunto , Sensibilidad y Especificidad , Eficiencia , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/normas , Exactitud de los Datos
2.
Endocrine ; 56(3): 504-508, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28386723

RESUMEN

OBJECTIVE: To evaluate two variables affecting Thyroglobulin stability in the washout of fine needle aspiration biopsies of thyroid nodules and metastatic lymph nodes. MATERIALS AND METHODS: Thyroglobulin stability after storage at -20 °C up to 14 days was studied in washout performed with normal saline solution and further dilutions with normal saline solution from five metastatic thyroid nodes and six benign thyroid nodules. We also studied thyroglobulin stability in diluents compared with normal saline solution: 4% bovine serum albumin in normal saline solution and diluents free from thyroglobulin or Calcitonin or parathyroid hormone in paired and simultaneous thyroglobulin measurements of washout dilutions from 5/6 benign thyroid nodules and 2/5 metastatic lymph nodes. Thyroglobulin and Thyroglobulin antibodies were measured by a chemiluminescent assay. Positive samples with thyroglobulin antibodies in serum and/or washout were excluded. RESULTS: Thyroglobulin decreased with storage in washout or dilutions of washout performed in normal saline solution (p < 0.05). Lower thyroglobulin concentrations, close to the commonly used cut-off (1.1 ng/mL), showed the highest decrease as soon as after 1 day of storage. Diluents other than normal saline solution stabilized thyroglobulin in dilutions of all washout. CONCLUSIONS: The results suggest that the reliability of thyroglobulin measurements in washout of fine needle aspirates could be preserved by immediate measure of thyroglobulin or the use of stabilizing diluents to perform washout.


Asunto(s)
Manejo de Especímenes/métodos , Tiroglobulina/análisis , Neoplasias de la Tiroides/diagnóstico , Nódulo Tiroideo/diagnóstico , Biopsia con Aguja Fina , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Pruebas de Función de la Tiroides , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA