Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 76
Filtrar
1.
J Adv Periodontol Implant Dent ; 16(1): 64-71, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39027210

RESUMEN

Rehabilitating thin jaws without reconstructive surgery entails using narrow implants. The proposed treatment adopted an innovative implant system, allowing the mini-screws to be parallel and immediately loaded. A mandible, wearing an overdenture, was functionalized contextually to the residual dental extraction and the placement of six 2.4-mm thick one-piece implants. Low-profile intermediate abutments, the LEMs, able to rotate over the spherical heads of the fixtures, were connected after suturing, oriented, and blocked in a mutual parallel position. The copings, engaging with a tapered juncture of the LEMs, resulted in their alignment to be intraorally wedged together. The provisional superstructure enclosed the copings and was immediately connected to the implants, and the definitive prosthesis was delivered after three months. No clinical signs of peri-implantitis or radiographically evident bone loss were recorded after a two-year follow-up without any prosthetic complication. No cases have been published regarding mini-implants bearing fixed prosthesis rehabilitation.

2.
Quintessence Int ; 55(6): 442-458, 2024 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-38619260

RESUMEN

OBJECTIVES: This systematic review compares the impact of ball and locator attachments on marginal bone loss in implant-retained overdentures in completely edentulous patients. METHOD AND MATERIALS: Following PRISMA guidelines, health science librarians completed literature searches from inception to 17 March 2023 in seven databases. There were 15,686 items exported to EndNote from Embase.com, CINAHL (EBSCO), Cochrane Library, Ovid MEDLINE-ALL, PubMed, Scopus, and Web of Science. Hand-searching added four more articles. After deduplication, 6,756 items were screened for eligibility. Twenty-nine studies were assessed by full text, of which ten studies, involving 424 subjects, were included in the review. Risk of bias assessment was conducted using the Cochrane risk-of-bias tool and the Newcastle-Ottawa scale. A meta-analysis was performed to synthesize and analyze the collective data from the selected studies. RESULTS: The included studies used diverse methodologies, implant systems, and loading protocols. Most studies reported no significant difference in marginal bone loss between ball and locator attachments. The meta-analysis revealed high heterogeneity. CONCLUSION: The results of this systematic review suggest that ball and locator attachments exhibit similar performance in terms of marginal bone loss in implant-retained overdentures. However, the limited number, risk of bias, and heterogeneity of studies highlight the need for standardized research designs and larger sample sizes in future investigations to draw more definitive conclusions.


Asunto(s)
Pérdida de Hueso Alveolar , Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Humanos , Retención de Dentadura/instrumentación
3.
Heliyon ; 9(12): e23047, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38125455

RESUMEN

Purpose: Novel terms describing several designs of resin-bonded fixed partial dentures (RBFPDs) continue to appear. Indeed, a variety of terms are used in the English scientific literature The use of a standard terminology is important for a fair and efficient understanding. This study aimed to investigate if the terminology used to describe designs and retention methods for anterior RBFPDs is standard. Methods: An electronic search in the English literature was conducted in PubMed/Medline to identify all publications reporting RBFPDs in the anterior region until August 2022. This search was completed by hand searching. Terms indicating different designs of RBFPDs were listed and then classified. Percentages of their use were calculated to determine the commonly used terms. Analysis of the use of these terms was performed based on the standards determined by the latest edition of the Glossary of Prosthodontic Terms (GPT). The impacts of the MeSH Thesaurus and GPT on the nomenclature used for RBFPDs was assessed. Results: A total of 125 articles were eligible for this review. In the retained articles, 86 terms were found. Among them, thirty-nine terms were classified into three groups. Only six terms were defined in the latest edition of GPT (GPT-9). Several classified terms that are commonly used were not identified in the GPT-9. Conversely to the GPT-9 which impact was insignificant, the MeSH Thesaurus had an important impact on the nomenclature used for RBFPDs. Conclusion: The terminology used to describe designs and retention methods for anterior RBFPDs was non-standard. The GPT-9, constituting an important reference, defined a limited number of terms related to RBFPDs and had no significant impact on the standardization of the terminology used for RBFPDs. Efforts should therefore be continued to standardize the terminology. A specialized mini-glossary grouping and defining all the terms found in this study will helpful in clarifying the terminology used for the anterior RBFPDs.

4.
Beijing Da Xue Xue Bao Yi Xue Ban ; 55(3): 548-552, 2023 Jun 18.
Artículo en Chino | MEDLINE | ID: mdl-37291933

RESUMEN

OBJECTIVE: To analyze the cement flow in the abutment margin-crown platform switching structure by using the three-dimensional finite element analysis, in order to prove that whether the abutment margin-crown platform switching structure can reduce the inflow depth of cement in the implantation adhesive retention. METHODS: By using ANSYS 19.0 software, two models were created, including the one with regular margin and crown (Model one, the traditional group), and the other one with abutment margin-crown platform switching structure (Model two, the platform switching group). Both abutments of the two models were wrapped by gingiva, and the depth of the abutment margins was 1.5 mm submucosal. Two-way fluid structure coupling calculations were produced in two models by using ANSYS 19.0 software. In the two models, the same amount of cement were put between the inner side of the crowns and the abutments. The process of cementing the crown to the abutment was simulated when the crown was 0.6 mm above the abutment. The crown was falling at a constant speed in the whole process spending 0.1 s. Then we observed the cement flow outside the crowns at the time of 0.025 s, 0.05 s, 0.075 s, 0.1 s, and measured the depth of cement over the margins at the time of 0.1 s. RESULTS: At the time of 0 s, 0.025 s, 0.05 s, the cements in the two models were all above the abutment margins. At the time of 0.075 s, in Model one, the gingiva was squeezed by the cement and became deformed, and then a gap was formed between the gingiva and the abutment into which the cement started to flow. In Model two, because of the narrow neck of the crown, the cement flowed out from the gingival as it was pressed by the upward counterforce from the gingival and the abutment margin. At the time of 0.1 s, in Model one, the cement continued to flow deep inside with the gravity force and pressure, and the depth of the cement over the margin was 1 mm. In Model two, the cement continued to flow out from the gingival at the time of 0.075 s, and the depth of the cement over the margin was 0 mm. CONCLUSION: When the abutment was wrapped by the gingiva, the inflow depth of cement in the implantation adhesive retention can be reduced in the abutment margin-crown platform switching structure.


Asunto(s)
Cementación , Encía , Análisis de Elementos Finitos , Cementación/métodos , Coronas , Pilares Dentales , Cementos Dentales , Análisis del Estrés Dental
5.
Heliyon ; 9(5): e16219, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37215792

RESUMEN

Objectives: CAD/CAM hybrid materials have become increasingly utilized in restorative dentistry. However, their low tensile bond strength (TBS) may lead to the detachment of minimally invasive restorations. When prepared, an experimental enamel-based biopolymer prosthesis provided a honeycomb-like interfacial layer with luting adhesives leading to a higher TBS than Ni-Cr-Be based alloy, lithium disilicate-based ceramic, and cured-resin-composite. This study aimed to compare TBSs of dental veneers fabricated from experimental biopolymer and commercial hybrid materials bonded to enamel using two different luting adhesives. Methods: Laminate veneers (4 × 4 mm) 1 mm thick were prepared from commercial CAD/CAM blocks: VITA ENAMIC, SHOFU Block HC, KATANA AVENCIA, and an experimental biopolymer. The flat bonding surface of the veneers was ground to 600-grit, followed by 50-µm alumina air-abrading for standardization. Each veneer was fixed on flat ground bovine enamel using either Super-Bond C&B or RelyX™ U200 resin (n = 10). The surface treatment and bonding procedures were treated as recommended by the manufacturers. All bonded specimens were stored in water at 37 °C for 24 h before tensile testing with a universal testing machine at a cross-headed speed of 1.0 mm/min. The fractured surface was examined with a stereomicroscope and scanning electron microscope. TBS data were statistically analyzed using two-way ANOVA and Tukey's HSD test (α = 0.05). Results: Experimental biopolymer veneers demonstrated the highest mean TBS with cohesive failure in the luting agents. Adhesive failure at the veneer side interface was found in other groups. There was no significant difference between the two luting agents. Conclusion: The results indicate that the experimental biopolymer veneer bonded to enamel provided the best retention. The TBS at the enamel-resin interface is higher than at the veneer-resin interface for all commercial CAD/CAM hybrid materials. Clinical significance: An experimental enamel-based biopolymer veneer can provide better retention than CAD/CAM hybrid materials in clinical treatment.

6.
Prim Dent J ; 12(1): 51-56, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36916614

RESUMEN

Fibrous ridges on the edentulous maxillary arch are commonly found in combination syndrome or due to ill-fitting dentures. Often, these cases are managed conservatively using modified impression techniques to achieve better support and peripheral seal without displacing the movable tissue. Many impression techniques were proposed and justified with their respective ideologies, but some may complicate both the clinical and laboratory procedures. In this report, two simplified techniques are demonstrated to make an impression of the maxillary arch with fibrous ridges. Laboratory steps in custom tray fabrication are also emphasised for a successful and predictable impression.


Asunto(s)
Arcada Edéntula , Boca Edéntula , Humanos , Diseño de Dentadura , Materiales de Impresión Dental , Técnica de Impresión Dental , Maxilar
7.
J Prosthodont ; 32(2): 154-161, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35343624

RESUMEN

PURPOSE: To assess the retentive force of telescopic crowns using polyetherketoneketone (PEKK) high-performance polymer in relation to conventional materials over a long period of time in an in vitro setting. MATERIALS AND METHODS: Thirty-six sets of primary and secondary crowns were fabricated as per the double crown-retained prostheses approach. Six samples were included in each of the five test groups (1: zirconia/PEKK [Zr/PEKK]; 2: titanium/PEKK [Ti/PEKK]; 3: cobalt-chrome/PEKK [CoCr/PEKK]; 4: PEKK/PEKK; and 5: gold/PEKK [Au/PEKK]) and the single control group (gold/galvano-gold [Au/GA]). The insertion-removal test was performed for 20,000 cycles, and the surface condition was observed. Retentive forces were analyzed using two-way ANOVA (α<0.05). RESULTS: The retention forces in groups Zr/PEKK and Ti/PEKK significantly decreased over time (group 1: p = 0.035 and group 2: p = 0.001), whereas retentive force increased significantly in groups PEKK/PEKK, Au/PEKK, and control (group 4: p = 0.001, group 5: p = 0.008, and control: p = 0.042). Similar wear was observed on the primary crown in groups PEKK/PEKK, gold/PEKK, and control. CONCLUSIONS: Groups PEKK/PEKK and Au/PEKK showed a transition of retentive force similar to the control group. Groups PEKK/PEKK and Au/PEKK had similar wear on the surface compared to control. Therefore, PEKK has a promising clinical potential.


Asunto(s)
Retención de Dentadura , Retención de la Prótesis , Polímeros , Coronas , Análisis del Estrés Dental
8.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-986888

RESUMEN

OBJECTIVE@#To analyze the cement flow in the abutment margin-crown platform switching structure by using the three-dimensional finite element analysis, in order to prove that whether the abutment margin-crown platform switching structure can reduce the inflow depth of cement in the implantation adhesive retention.@*METHODS@#By using ANSYS 19.0 software, two models were created, including the one with regular margin and crown (Model one, the traditional group), and the other one with abutment margin-crown platform switching structure (Model two, the platform switching group). Both abutments of the two models were wrapped by gingiva, and the depth of the abutment margins was 1.5 mm submucosal. Two-way fluid structure coupling calculations were produced in two models by using ANSYS 19.0 software. In the two models, the same amount of cement were put between the inner side of the crowns and the abutments. The process of cementing the crown to the abutment was simulated when the crown was 0.6 mm above the abutment. The crown was falling at a constant speed in the whole process spending 0.1 s. Then we observed the cement flow outside the crowns at the time of 0.025 s, 0.05 s, 0.075 s, 0.1 s, and measured the depth of cement over the margins at the time of 0.1 s.@*RESULTS@#At the time of 0 s, 0.025 s, 0.05 s, the cements in the two models were all above the abutment margins. At the time of 0.075 s, in Model one, the gingiva was squeezed by the cement and became deformed, and then a gap was formed between the gingiva and the abutment into which the cement started to flow. In Model two, because of the narrow neck of the crown, the cement flowed out from the gingival as it was pressed by the upward counterforce from the gingival and the abutment margin. At the time of 0.1 s, in Model one, the cement continued to flow deep inside with the gravity force and pressure, and the depth of the cement over the margin was 1 mm. In Model two, the cement continued to flow out from the gingival at the time of 0.075 s, and the depth of the cement over the margin was 0 mm.@*CONCLUSION@#When the abutment was wrapped by the gingiva, the inflow depth of cement in the implantation adhesive retention can be reduced in the abutment margin-crown platform switching structure.


Asunto(s)
Análisis de Elementos Finitos , Cementación/métodos , Encía , Coronas , Pilares Dentales , Cementos Dentales , Análisis del Estrés Dental
9.
J Prosthodont ; 32(3): 214-220, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35964246

RESUMEN

PURPOSE: To determine the survival rate, incidence of prosthetic complications, and patient satisfaction of implant fixed complete dental prostheses (IFCDPs) after a mean observation period of 1.4 years. MATERIALS AND METHODS: Twenty-eight (28) eligible participants were recruited according to specific inclusion and exclusion criteria. The definitive metal-acrylic resin IFCDPs consisted of titanium bars veneered with acrylic resin and acrylic denture teeth. Prosthodontic complications, divided into major and minor, were monitored. Parameters such as gender, jaw location, bruxism, and occlusal scheme were evaluated. Moreover, a questionnaire was administered throughout the study to assess patient satisfaction. Poisson regression as well as repeated measures ANOVA were used for statistical analysis. RESULTS: Fourteen (14) males and 14 females were enrolled and followed-up at 3, 6, and 12 months. All IFCDPs survived (100% survival rate). The most frequent minor complication was the loss of material used to close the screw access hole (20% out of total complications). The most frequent major complication was chipping of the acrylic denture teeth (77.14% out of total complications). Gender (p = 0.008) and bruxism (p = 0.030) were significant predictors for the total major complications (major wear and major chipping) while occlusal scheme was a significant predictor for major chipping events (p = 0.030). CONCLUSIONS: While IFCDPs demonstrated high prosthetic survival rates, they also exhibited a high number of chipping events of the acrylic veneering material, especially in males, bruxers, and individuals with canine guidance occlusion. However, the occurrence of these prosthetic complications did not negatively affect patient satisfaction.


Asunto(s)
Bruxismo , Implantes Dentales , Masculino , Femenino , Humanos , Estudios Prospectivos , Tasa de Supervivencia , Satisfacción del Paciente , Fracaso de la Restauración Dental , Estudios Retrospectivos , Resinas Acrílicas
10.
Natl J Maxillofac Surg ; 14(3): 499-503, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38273915

RESUMEN

Surgical reconstruction of the missing external ear is difficult, and the results are often far from satisfactory. An implant-retained auricular prosthesis is a suitable alternative. Microtia, malformation, deformity, and partial or complete loss of the external ear may be due to various congenital or acquired factors. A case series of three patients treated with implant-retained auricular prostheses is presented in this article. For each missing pinna, two titanium implants were placed in the temporal bone. After 6 months of osseointegration, the implants were loaded. All three cases were rehabilitated with a bar and clip retained prosthesis. There were two male and one female patient with an average age of 16.6 years. One patient had unilateral absence of external ear and two had bilateral absence. A total of 10 implants were placed, 4 on the right side and 6 on the left. The average post rehabilitation follow-up was 18 months. Peri-implant tissue reactions were observed at two sites. The implant-retained auricular prosthesis is an alternative treatment approach with good retention and patient satisfaction. Long-term follow-up is required to assess delayed sequelae.

11.
Heliyon ; 8(12): e12411, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36582682

RESUMEN

Aim: The objective of this systematic review is to show the current state of the art on which type of attachment loses retention the most and has reduced durability and which factor causes these problems the most. Material and methods: This review followed the Preferred Reporting Items for Systematic Review and MetaAnalysis (PRISMA) guidelines and it was registered with the Open Science Framework (OSF) (osf.io/2e3q5). The databases used for the electronic search of articles were Pubmed, Science Direct, Embase, and Scopus. Articles were selected by 2 independent reviewers according to the inclusion criteria. The risk of bias was analyzed by using the Joanna Briggs Institute (JBI) adapted quasi-experimental study evaluation tool. Results: The studies included in this review indicate that the use of cleansing solutions, high temperatures, and a more acidic pH decrease the durability of the attachments, mainly due to the loss of retention that occurs in different models and materials of the attachments, which requires their replacement in a shorter period. Conclusion: Of all the factors studied, the cleansing solutions proved to be the factor that most altered attachment retention. Different saliva compositions did not influence retention values. Aging changes retention values for attachments, mostly with loss of values.

12.
Acta Ortop Bras ; 30(5): e251150, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36451786

RESUMEN

Brazil lacks registries on the prevalence of primary total hip arthroplasty (THA) fixation methods. Objective: (i) to describe the demographic profile of patients who underwent THA in the public health system of the municipality of São Paulo during the last 12 years and (ii) to compare fixation methods regarding costs, hospital stay length, and death rates. Methods: This is an ecological study conducted with data available on TabNet, a platform belonging to DATASUS. Public data (from the government health system) on THA procedures performed in São Paulo from 2008 to 2019 were extracted. Gender, age, city region, THA fixation method, number of surgeries, costs, hospital stay length, and death rates were analyzed. Results: We analyzed 7,673 THA, of which 6220 (81%) were performed via cementless/hybrid fixation and 1453 (19%), via the cemented technique. Cementless/hybrid fixation had a higher cost (US$ 495.27) than the cemented one (p < 0.001). Nevertheless, hospital stay length was 0.87 days longer for cemented fixation than the cementless/hybrid one. We found no significant difference in death rates between THA fixation methods. Conclusion: THA cementless/hybrid fixation is prevalent in the municipality of São Paulo, which had higher total costs and shorter hospitalizations than cemented fixation. We found no difference between THA fixation methods and death rates. Level of Evidence IV, Case Series.


No Brasil, não há registros da prevalência do tipo de fixação da artroplastia total de quadril (ATQ). Objetivo: (i) Descrever perfil demográfico de pacientes submetidos à ATQ no Sistema Único de Saúde de São Paulo durante os últimos doze anos; e (ii) comparar as técnicas de fixação de ATQ quanto aos custos, tempo de internação (TI) e taxa de óbito. Métodos: Estudo ecológico, com dados disponíveis na TabNet do DATASUS. Dados públicos de procedimentos de ATQ eletivos realizados em São Paulo de 2008 a 2019 foram extraídos. Foram analisados: sexo, idade, região municipal, método de fixação em ATQ, número de cirurgias, custo, tempo de internação e óbitos. Resultados: Foram analisadas 7.673 ATQs, sendo 6.220 (81%) não-cimentada/híbridas e 1.453 (19%) cimentadas. A fixação não-cimentada/híbrida teve custo maior em US$ 495,27 do que a cimentada (p < 0,001). Entretanto, TI foi 0,87 dia mais longo na fixação cimentada. Não houve diferença significativa nas taxas de óbito entre os métodos de fixação. Conclusão: A fixação não-cimentada/híbrida na ATQ é prevalente em São Paulo, e apresentou maior custo total, porém menor tempo de internação do que a fixação cimentada. Não houve diferença entre o método de fixação em ATQ e a taxa de óbito. Nível de Evidência IV, Série de Casos.

13.
Acta Neurochir (Wien) ; 164(12): 3101-3106, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36214913

RESUMEN

BACKGROUND: Titanium mesh exposure after cranioplasty is a possible complication and is usually managed by mesh removal and flap transfer, but the advantages of the rigid prosthesis are then lost. This study aimed to present our experience with negative pressure wound therapy combined with soft tissue dilation for retaining the titanium mesh in patients with mesh exposure after cranioplasty. METHODS: This retrospective study included patients treated between 01/2016 and 05/2019 at the Jiangyin Hospital Affiliated to Southeast University School of Medicine. The wound was cleaned, and a cystic space was created for the tissue dilator, which was used with a self-designed negative pressure dressing. After the target dilation was achieved, the repair was conducted while retaining the titanium mesh. RESULTS: Eight patients were included (seven males and one female; 53.6 ± 8.8 (range, 43-65) years of age). The exposed mesh area ranged from 1 × 1 to 4 × 5.5 cm. The thinning scalp area around the exposed mesh ranged from 3.6 × 3.8 to 4 × 5.5 cm. Five patients had positive wound cultures and received sensitive antibiotics. The dilator embedding time was 20-28 days. The time of negative pressure wound therapy was 25-33 days. The hospital stay was 30-41 days. Primary wound healing was achieved in all eight patients. There were no signs of recurrence after 6-18 months of follow-up. The cranial CT scans were unremarkable. CONCLUSIONS: Negative pressure wound therapy combined with soft tissue dilation for exposed titanium mesh after cranioplasty might help retain the titanium mesh.


Asunto(s)
Procedimientos de Cirugía Plástica , Complicaciones Posoperatorias , Cráneo , Mallas Quirúrgicas , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Procedimientos de Cirugía Plástica/efectos adversos , Estudios Retrospectivos , Cráneo/cirugía , Mallas Quirúrgicas/efectos adversos , Titanio
14.
Rev. Odontol. Araçatuba (Impr.) ; 43(2): 49-54, maio-ago. 2022.
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-1362035

RESUMEN

Overdenture é uma prótese total que se caracteriza por usar apoios retentivos para que aumente sua estabilidade e retenção na cavidade bucal, gerando assim menor desconforto ao paciente e melhor adaptação. A Prótese overdenture dentossuportada necessita de elementos dentais remanescentes com canais tratados endodonticamente e que possuam suporte periodontal adequado. O objetivo deste relato de caso clínico é expor a sequência de confecção de uma prótese overdenture dentossuportada maxilar associada a uma prótese total convencional mandibular, com os passos clínicos detalhados por meio de uma abordagem teórica e visual. Esse tipo de reabilitação favorece a adaptação do paciente à nova condição, visto que o uso de próteses totais convencionais pode causar certo desconforto ao paciente devido à falta de retenção e estabilidade. Essa manutenção dos dentes remanescentes favorece à manutenção óssea e a futura decisão do paciente em optar pela instalação de implantes dentários, podendo confeccionar próteses implantorretidas (overdentures) ou implantossuportadas (protocolo).O Paciente demonstrou-se satisfeito com o resultado estético e funcional após a instalação da prótese concretizando que o tratamento é viável(AU)


Overdenture is a denture that utilizing retentive supports for increase stability and retention in oral cavity. The tooth-supported overdenture require dental elements with root canal therapy and good periodontal support. The aim of this study is to report the confection of a maxillary tooth-supported overdenture associated with mandibular denture and your clinical steps. This rehabilitation promotes the patient's adaptation the new condition, since the use of conventional dentures may cause discomfort due to lack of retention and stability. The preservation of dental elements promotes bone maintenance and forthcoming decision of the patient in the installation of dental implants that can choose implantretained or implant-supported prosthesis. Patient was satisfied with aesthetic and functional result after installation of prosthesis(AU)


Asunto(s)
Humanos , Masculino , Retención de Dentadura , Dentadura Completa , Prótesis de Recubrimiento , Retención de Prótesis Dentales , Prótesis Dental
15.
Materials (Basel) ; 15(9)2022 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-35591322

RESUMEN

The rotational movement of mini dental implants (MDIs) overdenture disturbs the function of the prosthesis. Many dentists place more MDIs to improve the overdenture stability; however, the influence of the MDIs number and distribution on the overdenture resistance to para-axial dislodgment has not been investigated. Seven resin models simulating atrophic mandibles housed twenty MDIs placed according to seven arrangements. Acrylic overdentures were fabricated for each cast and were dislodged five times in lateral, anterior and posterior directions, and the peak load dislodgment was measured. Each overdenture underwent 540 axial removal/placement cycles. The para-axial dislodgments were measured again, and data were compared. Dislodgment force values were measured in all directions, and the data were analysed using analysis of variance ANOVA and post hoc (p < 0.05). After six months of simulated placement/removal, increasing the MDI number showed a difference in resistance to para-axial dislodgment. The distribution affected the resistance to dislodgment in some directions. The inter-implant distance of 27 mm provided better resistance to posterior dislodgment than placing two MDIs close together at 19 mm. The placement of three MDIs at any distribution showed no significant difference except for resistance to posterior dislodgment. FourMDIs placed at any distribution showed a significant difference in all groups in all tested directions. The resistance to the para-axial dislodgment of MDI overdenture could improve with the increasing MDIs number and careful planning of MDI distribution.

16.
Rev. Odontol. Araçatuba (Impr.) ; 43(1): 51-56, jan.-abr. 2022. ilus
Artículo en Portugués | LILACS, BBO - Odontología | ID: biblio-1361718

RESUMEN

Este trabalho teve como objetivo apresentar um relato de caso clínico de uma restauração do tipo coroa endocrown cerâmica em um dente molar tratado endodonticamente. Paciente com 45 anos de idade, sexo feminino, procurou a clínica do Centro Universitário da Serra Gaúcha (FSG) relatando a necessidade de reabilitação protética no primeiro molar inferior do lado esquerdo. Com base no exame radiográfico e exame clínico foi constatado um primeiro molar inferior do lado esquerdo com tratamento endodôntico satisfatório, mas uma extensa destruição coronária. Após a aprovação da paciente e indicações para a utilização da técnica, optou-se pela confecção de uma coroa endocrown em cerâmica reforçada por dissilicato de lítio. Foi realizado o preparo do remanescente dentário, envolvendo a câmara pulpar, com ângulos arredondados e expulsivos e, após a moldagem do mesmo com silicone de adição, utilizando a técnica simultânea e duplo fio. O provisório foi realizado com resina quimicamente ativada na cor 62 e, na sessão seguinte a coroa endocrown foi ajustada e polida. Após receber o protocolo de condicionamento adequado da peça, a mesma foi cimentada com cimento autopolimerizável Multilink N. Pode-se concluir que a alternativa restauradora Endocrown é um tratamento conservador e favorável para dentes com extensa destruição coronária, permitindo adequada estética e função(AU)


This study aimed to present a clinical case report of an endocrown ceramic crown restoration in na endodontically treated molar tooth. A 45-year-old female patient sought the clinic at the Centro Universitário da Serra Gaúcha (FSG), reporting the need for prosthetic rehabilitation on the lower left first molar. Based on the radiographic and clinical examination, the first molar presented satisfactory endodontic treatment, but extensive coronary destruction. After the approval of the patient and indications for the use of the technique, it was decided to make an endocrown with reinforced ceramic by lithium disilicate. The remaining tooth was prepared, involving the pulp chamber, with rounded and expulsive angles and, after the impression with silicone using the simultaneous and double wire technique was taken. The provisional was made with chemically activated resin in color 62 and, in the following session, the endocrown crown was adjusted and polished. After receiving the proper conditioning protocol, it was lutted with Multilink N self-curing cement. It can be concluded that the Endocrown restorative alternative is a conservative and favorable treatment for teeth with extensive coronary destruction, allowing adequate aesthetics and function(AU)


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Cerámica , Diente no Vital , Coronas , Diente Molar , Prótesis Dental , Cavidad Pulpar , Retención de la Prótesis
17.
Beijing Da Xue Xue Bao Yi Xue Ban ; 54(1): 187-192, 2022 Feb 18.
Artículo en Chino | MEDLINE | ID: mdl-35165489

RESUMEN

OBJECTIVE: To compare the operation complexity and accuracy of traditional splint impression technique and impression technique with prefabricated rigid connecting bar system for full-arch implants-supported fixed protheses in vitro. METHODS: Standard mandibular edentulous model with six implant analogs was prepared. The implants were placed at the bone level and multiunit abutments screwed into the implants. Two impression techniques were performed: the traditional splint impression technique was used in the control group, and the rigid connecting bar system was used in the test group. In the control group, impression copings were screwed into the multiunit abutments and connected with autopolymerizing acrylic resin. Open tray impression was fabricated with custom tray and polyether. In the test group, cylinders were screwed into the multiunit abutments. Prefabricated rigid bars with suitable length were selected and connected to the cylinders with small amount of autopolymerizing acrylic resin, and open tray impression was obtained. Impression procedures were repeated 6 times in each group. The working time of the two impression methods were recorded and compared. Analogs were screws into the impressions and gypsum casts were poured. The gypsum casts and the standard model were transferred to stereolithography (STL) files with model scanner. Comparative analysis of the STL files of the gypsum casts and the standard model was carried out and the root mean square (RMS) error value of the gypsum casts of the control and test groups compared with the standard model was recorded. The trueness of the two impression techniques was compared. RESULTS: The work time in the test group was significantly lower than that in the control group and the difference was statistically significant [(984.5±63.3) s vs. (1 478.3±156.2) s, P < 0.05]. Compared with the standard model, the RMS error value of the implant abutments in the test group was (16.9±5.5) µm. The RMS value in the control group was (20.2±8.0) µm. The difference between the two groups was not significant (P>0.05). CONCLUSION: The prefabricated rigid connecting bar can save the chair-side work time in implants immediate loading of edentulous jaw and simplify the impression process. The impression accuracy is not significantly different from the traditional impression technology. The impression technique with prefabricated rigid connecting bar system is worthy of clinical application.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Boca Edéntula , Resinas Acrílicas , Sulfato de Calcio , Materiales de Impresión Dental , Técnica de Impresión Dental , Humanos , Modelos Dentales
18.
BMC Oral Health ; 22(1): 41, 2022 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-35172792

RESUMEN

BACKGROUND: This study aimed to compare retention and fracture load in endocrowns made from translucent zirconia and zirconium lithium silicate. METHODS: Fifty-six intact human maxillary molars after being mounted in acrylic resin, were scanned to acquire biogeneric copies. Specimens underwent standard endodontic treatment and were prepared for endocrown up to 2 mm above the cementoenamel junction. The specimens were randomly divided into two groups of 28, and endocrowns were designed using biogeneric copies and milled from high-translucent zirconia disks (Zr) and zirconium lithium silicate blocks (ZLS). After cementation with dual-cure resin cement, all the specimens underwent thermomechanical aging, and pull-out retention test and compressive test were conducted (14 specimens were used for each test in each group, n = 14), and failure modes in both tests were evaluated. RESULTS: Independent samples t-test showed significant difference between the retention of Zr (271.5 N ± 114.31) and ZLS (654.67 N ± 223.17) groups (p value = 0.012). Compressive test results were also significantly different between Zr (7395.07 N ± 1947.42) and ZLS (1618.3 N ± 585) (p = 0.002). Failure mode of retention test was primarily adhesive failure at the cement-restoration interface in Zr group and cement-tooth interface in ZLS group. Failure modes of fracture test for Zr group were 7 non-restorable fractures and one restorable fracture while 6 specimens resisted compressive loads up to 8500 N without fracture. ZLS group showed 7 restorable and 7 non-restorable failures. CONCLUSIONS: Zr endocrowns showed significantly lower retention and higher fracture strength. Both materials seem to be suitable for fabrication of endocrown in clinical setup.


Asunto(s)
Litio , Circonio , Cerámica , Diseño Asistido por Computadora , Coronas , Porcelana Dental , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Humanos , Ensayo de Materiales , Silicatos
19.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-936133

RESUMEN

OBJECTIVE@#To compare the operation complexity and accuracy of traditional splint impression technique and impression technique with prefabricated rigid connecting bar system for full-arch implants-supported fixed protheses in vitro.@*METHODS@#Standard mandibular edentulous model with six implant analogs was prepared. The implants were placed at the bone level and multiunit abutments screwed into the implants. Two impression techniques were performed: the traditional splint impression technique was used in the control group, and the rigid connecting bar system was used in the test group. In the control group, impression copings were screwed into the multiunit abutments and connected with autopolymerizing acrylic resin. Open tray impression was fabricated with custom tray and polyether. In the test group, cylinders were screwed into the multiunit abutments. Prefabricated rigid bars with suitable length were selected and connected to the cylinders with small amount of autopolymerizing acrylic resin, and open tray impression was obtained. Impression procedures were repeated 6 times in each group. The working time of the two impression methods were recorded and compared. Analogs were screws into the impressions and gypsum casts were poured. The gypsum casts and the standard model were transferred to stereolithography (STL) files with model scanner. Comparative analysis of the STL files of the gypsum casts and the standard model was carried out and the root mean square (RMS) error value of the gypsum casts of the control and test groups compared with the standard model was recorded. The trueness of the two impression techniques was compared.@*RESULTS@#The work time in the test group was significantly lower than that in the control group and the difference was statistically significant [(984.5±63.3) s vs. (1 478.3±156.2) s, P < 0.05]. Compared with the standard model, the RMS error value of the implant abutments in the test group was (16.9±5.5) μm. The RMS value in the control group was (20.2±8.0) μm. The difference between the two groups was not significant (P>0.05).@*CONCLUSION@#The prefabricated rigid connecting bar can save the chair-side work time in implants immediate loading of edentulous jaw and simplify the impression process. The impression accuracy is not significantly different from the traditional impression technology. The impression technique with prefabricated rigid connecting bar system is worthy of clinical application.


Asunto(s)
Humanos , Resinas Acrílicas , Sulfato de Calcio , Implantes Dentales , Materiales de Impresión Dental , Técnica de Impresión Dental , Arcada Edéntula , Modelos Dentales , Boca Edéntula
20.
Spec Care Dentist ; 42(3): 209-215, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34791692

RESUMEN

AIMS: This study aimed to assess the longevity of a fixed prosthesis in patients with intellectual disability (ID) and to investigate the risk factors associated with the failure of a prosthesis due to abutment tooth extraction or prosthesis dislodgement or removal. METHODS: We studied past medical records to evaluate the longevity of 315 prostheses that were luted in 76 patients with ID. We calculated the survival rates and assessed 15 variables potentially associated with prosthetic failure using multivariate Cox regression analyses with shared frailty for patients. RESULTS: Three-quarters of our sample population had severe or profound ID. The maximum observation period was 31.0 years, and the corresponding survival ratio was 32.5%; the survival ratio at 10 years was 59.4%. The use of intravenous sedation significantly influenced the success of the prosthesis, with the hazard ratio (HR) being 0.49 times that of conventional treatment without behavior-altering drug therapy. The most significant risk factor for prosthetic failure was age at placement; the HR for patients aged ≥31 years was 2.82 times that for patients aged ≤ 20 years. CONCLUSIONS: In patients with severe ID, appropriate intravenous sedation was effective in prolonging the longevity of a fixed prosthesis.


Asunto(s)
Implantes Dentales , Discapacidad Intelectual , Adulto , Atención Odontológica , Prótesis Dental de Soporte Implantado/efectos adversos , Fracaso de la Restauración Dental , Estudios de Seguimiento , Humanos , Discapacidad Intelectual/complicaciones , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA