Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
Talanta ; 277: 126417, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38901191

RESUMEN

Agronomic biofortification using selenium nanoparticles (SeNPs) shows potential for addressing selenium deficiency but further research on SeNPs-plants interaction is required before it can be effectively used to improve nutritional quality. In this work, single-particle inductively coupled plasma-mass spectrometry (SP-ICP-MS) was used for tracing isotopically labeled SeNPs (82SeNPs) in Oryza sativa L. tissues. For this purpose, SeNPs with natural isotopic abundance and 82SeNPs were synthesized by a chemical method. The NPs characterization by transmission electron microscopy (TEM) confirmed that enriched NPs maintained the basic properties of unlabeled NPs, showing spherical shape, monodispersity, and sizes in the nano-range (82.8 ± 6.6 nm and 73.2 ± 4.4 nm for SeNPs and 82SeNPs, respectively). The use of 82SeNPs resulted in an 11-fold enhancement in the detection power for ICP-MS analysis, accompanied by an improvement in the signal-to-background ratio and a reduction of the size limits of detection from 89.9 to 39.9 nm in SP-ICP-MS analysis. This enabled 82SeNPs to be tracked in O. sativa L. plants cultivated under foliar application of 82SeNPs. Tracing studies combining SP-ICP-MS and TEM-energy-dispersive X-ray spectroscopy data confirmed the uptake of intact 82SeNPs by rice leaves, with most NPs remaining in the leaves and very few particles translocated to shoots and roots. Translocation of Se from leaves to roots and shoots was found to be lower when applied as NPs compared to selenite application. From the size distributions, as obtained by SP-ICP-MS, it can be concluded that a fraction of the 82SeNPs remained within the same size range as that of the applied NP suspension, while other fraction underwent an agglomeration process in the leaves, as confirmed by TEM images. This illustrates the potential of SP-ICP-MS analysis of isotopically enriched 82SeNPs for tracing NPs in the presence of background elements within complex plant matrices, providing important information about the uptake, accumulation, and biotransformation of SeNPs in rice plants.


Asunto(s)
Espectrometría de Masas , Nanopartículas , Oryza , Selenio , Selenio/química , Selenio/análisis , Oryza/química , Oryza/metabolismo , Espectrometría de Masas/métodos , Nanopartículas/química , Marcaje Isotópico , Hojas de la Planta/química , Hojas de la Planta/metabolismo , Nanopartículas del Metal/química , Tamaño de la Partícula
2.
NanoImpact ; 35: 100518, 2024 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-38906249

RESUMEN

The development of engineered nanotechnology has necessitated a commensurate maturation of nanoanalysis capabilities. Building off a legacy established by electron microscopy and light-scattering, environmental nanoanalysis has now benefited from ongoing advancements in instrumentation and data analysis, which enable a deeper understanding of nanomaterial properties, behavior, and impacts. Where once environmental nanoparticles and colloids were grouped into broad 'dissolved or particulate' classes that are dependent on a filter size cut-off, now size distributions of submicron particles can be separated and characterized providing a more comprehensive examination of the nanoscale. Inductively coupled plasma-quadrupole mass spectrometry (ICP-QMS), directly coupled to field flow fractionation (FFF-ICP-QMS) or operated in single particle mode (spICP-MS) have spearheaded a revolution in nanoanalysis, enabling research into nanomaterial behavior in environmental and biological systems at expected release concentrations. However, the complexity of the nanoparticle population drives a need to characterize and quantify the multi-element composition of nanoparticles, which has begun to be realized through the application of time-of-flight MS (spICP-TOFMS). Despite its relative infancy, this technique has begun to make significant strides in more fully characterizing particulate systems and expanding our understanding of nanoparticle behavior. Though there is still more work to be done with regards to improving instrumentation and data processing, it is possible we are on the cusp of a new nanoanalysis revolution, capable of broadening our understanding of the size regime between dissolved and bulk particulate compartments of the environment.

3.
J Agric Food Chem ; 72(19): 11251-11258, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38699857

RESUMEN

Engineered nanoparticles (ENPs) have been increasingly used in agricultural operations, leading to an urgent need for robust methods to analyze co-occurring ENPs in plant tissues. In response, this study advanced the simultaneous extraction of coexisting silver, cerium oxide, and copper oxide ENPs in lettuce shoots and roots using macerozyme R-10 and analyzed them by single-particle inductively coupled plasma-mass spectrometry (ICP-MS). Additionally, the standard stock suspensions of the ENPs were stabilized with citrate, and the long-term stability (up to 5 months) was examined for the first time. The method performance results displayed satisfactory accuracies and precisions and achieved low particle concentration and particle size detection limits. Significantly, the oven drying process was proved not to impact the properties of the ENPs; therefore, oven-dried lettuce tissues were used in this study, which markedly expanded the applicability of this method. This robust methodology provides a timely approach to characterize and quantify multiple coexisting ENPs in plants.


Asunto(s)
Lactuca , Espectrometría de Masas , Nanopartículas del Metal , Raíces de Plantas , Nanopartículas del Metal/química , Lactuca/química , Espectrometría de Masas/métodos , Raíces de Plantas/química , Cobre/análisis , Brotes de la Planta/química , Plata/química , Cerio/química , Tamaño de la Partícula
4.
NanoImpact ; 34: 100503, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38514026

RESUMEN

TiO2 is the most widely used white pigment in plastics and food packaging industry, thus the question of its migration towards food and hence the impact on consumers is raised. Since recent research indicate its potential toxicity, it is necessary to study TiO2 contamination as a consequence of food storage. For this purpose, plastic containers from commercially-available dairy products and custom-made TiO2-spiked polypropylene materials were put in contact with 50% (v/v) ethanol and 3% (w/v) acetic acid, which were used here as food simulants. The migration assays were carried out under standard contact conditions of packaging use (as recommended by Commission Regulation (EU) N° 10/2011 for food contact migration testing), and under conditions of extreme mechanical degradation of the packaging. The TiO2 (nano)particles released in the food simulants were analysed by single particle inductively coupled plasma-tandem mass spectrometry in mass-shift mode and using a high efficiency sample introduction system (APEX™ Ω) to avoid matrix effects from food simulants. For the dairy product containers and for the spiked polypropylene, results showed release of TiO2 particles of rather large sizes (average size: 164 and 175 nm, respectively) under mechanical degradation conditions, i.e. when the polymeric structure is damaged. The highest amounts of TiO2 were observed in 50% ethanol after 10 days of storage at 50 °C (0.62 ng cm-2) for the dairy product containers and after 1 day of storage at 50 °C (0.68 ng cm-2) for the spiked polypropylene. However, the level of Ti released in particle form was very small compared to the total Ti content in the packaging and far below the acceptable migration limits set by European legislation. Release under standard contact conditions of use of the container was not measurable, thus the migration of TiO2 particles from this packaging to dairy products among storage is expected to be negligible.


Asunto(s)
Contaminación de Alimentos , Embalaje de Alimentos , Espectrometría de Masas en Tándem , Titanio , Titanio/análisis , Titanio/química , Contaminación de Alimentos/análisis , Polipropilenos/química , Polipropilenos/análisis , Tamaño de la Partícula , Nanopartículas/análisis , Nanopartículas/efectos adversos
5.
Molecules ; 29(5)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38474598

RESUMEN

Single-particle inductively coupled plasma mass spectrometry (spICP-MS) has been used for particle size measurement of diverse types of individual nanoparticles and micrometer-sized carbon-based particles such as microplastics. However, its applicability to the measurement of micrometer-sized non-carbon-based particles such as silica (SiO2) particles is unclear. In this study, the applicability of spICP-MS to particle size measurement of non-porous/mesoporous SiO2 microspheres with a nominal diameter of 5.0 µm or smaller was investigated. Particle sizes of these microspheres were measured using both spICP-MS based on a conventional calibration approach using an ion standard solution and scanning electron microscopy as a reference technique, and the results were compared. The particle size distributions obtained using both techniques were in agreement within analytical uncertainty. The applicability of this technique to the detection of metal-containing protein-binding mesoporous SiO2 microspheres was also investigated. Bound iron (Fe)-containing proteins (i.e., lactoferrin and transferrin) of mesoporous SiO2 microspheres were detected using Fe as a presence marker for the proteins. Thus, spICP-MS is applicable to the particle size measurement of large-sized and non-porous/mesoporous SiO2 microspheres. It has considerable potential for element-based detection and qualification of bound proteins of mesoporous SiO2 microspheres in a variety of applications.


Asunto(s)
Plásticos , Dióxido de Silicio , Dióxido de Silicio/química , Tamaño de la Partícula , Microesferas , Espectrometría de Masas/métodos
6.
Anal Chim Acta ; 1301: 342485, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38553115

RESUMEN

BACKGROUND: Ag-Au bimetallic nanoparticles (BNPs), synthesized by using citrate reduction of Ag and Au ions, were used as sensor for detection of Co2+. In order to optimize sensing performance, it is necessary to control the particle size and size distribution of the original Ag-Au BNPs. Therefore, analytical methods based on the use of single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) and flow-field flow fractionation (FlFFF)-ICP-MS were developed to track the signal of Ag and Au in bimetallic nanoparticles at each step of the procedure: BNP synthesis, aggregation and sensing in order to understand the sensing mechanism. To better understand colorimetric sensing of Co2+ using Ag-Au BNPs, various solution mixtures were analyzed by using SP-ICP-MS and FlFFF-ICP-MS. RESULTS: SP-ICP-MS provided the information on the core size, size distribution and particle number concentration, as well as the heterogeneity of the particles synthesized by using various citrate concentrations and metal ratios. FlFFF-ICP-MS offered the information on hydrodynamic size as well as the signal intensity ratio of Ag and Au in BNPs and for the understanding of the aggregation of BNPs arising from the [Co(II)(en)3]2+ complex surrounding the surface of the BNPs. Under optimum sensing condition, the use of SP-ICP-MS for BNPs assisted detection of Co2+ improved the sensitivity of Co2+ determination by 20-fold in comparison with the conventional spectrophotometric analysis. SIGNIFICANCE: The information obtained from SP-ICP-MS and FlFFF-ICP-MS can be combinedly used to understand sensing mechanism and to select the best condition for synthesis of BNPs used as sensor. This study illustrates the usefulness of SP-ICP-MS and FlFFF-ICP-MS in the nanoparticle-based sensor development research area.

7.
Anal Bioanal Chem ; 416(11): 2761-2772, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37987766

RESUMEN

Mushrooms are considered a valuable food source due to their high protein and fibre and low fat content, among the other health benefits of their consumption. Selenium is an essential nutrient and is renowned for its chemo-preventative properties. In this study, batches of selenium-enriched Lingzhi mushrooms were prepared by growing mycelium and fruit in substrates containing various concentrations of sodium selenite. The mushroom fruit accumulated low levels of selenium with selenomethionine being the most abundant form in all enriched samples. Conversely, the mycelium showed significant selenium accumulation but relatively low proportions of selenomethionine. The red colour of the selenium-enriched mycelia indicated the probable presence of selenium nanoparticles, which was confirmed by single-particle inductively coupled plasma-mass spectrometry. Mean particle diameters of 90-120 nm were observed, with size distributions of 60-250 nm. Additional analysis with transmission electron microscopy confirmed this size distribution and showed that the biogenic selenium nanoparticles were roughly spherical in shape and contained elemental selenium.


Asunto(s)
Agaricales , Nanopartículas , Reishi , Selenio , Selenio/análisis , Selenometionina/análisis , Agaricales/metabolismo , Reishi/metabolismo , Nanopartículas/química
8.
Nanomaterials (Basel) ; 13(23)2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38063714

RESUMEN

Commonly used sample introduction systems for inductively coupled plasma mass spectrometry (ICP-MS) are generally not well-suited for single particle ICP-MS (spICP-MS) applications due to their high sample requirements and low efficiency. In this study, the first completely 3D-printed, polymer SIS was developed to facilitate spICP-MS analysis. The system is based on a microconcentric pneumatic nebulizer and a single-pass spray chamber with an additional sheath gas flow to further facilitate the transport of larger droplets or particles. The geometry of the system was optimized using numerical simulations. Its aerosol characteristics and operational conditions were studied via optical particle counting and a course of spICP-MS measurements, involving nanodispersions and cell suspensions. In a comparison of the performance of the new and the standard (quartz microconcentric nebulizer plus a double-pass spray chamber) systems, it was found that the new sample introduction system has four times higher particle detection efficiency, significantly better signal-to-noise ratio, provides ca. 20% lower size detection limit, and allows an extension of the upper limit of transportable particle diameters to about 25 µm.

9.
Nanomaterials (Basel) ; 13(22)2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-37999311

RESUMEN

A method was developed for the determination of total titanium in food and food supplements by inductively coupled plasma mass spectrometry (ICP-MS) after microwave-assisted acid digestion of samples. Five food supplements, including one certified reference material, and 15 food products were used for method development. Key factors affecting the analytical results, such as the composition of the acid mixture for sample digestion and the bias from spectral interferences on the different titanium isotopes, were investigated. Resolution of interferences was achieved by ICP-MS/MS with ammonia adduct formation and viable conditions for control laboratories equipped with standard quadrupole instruments were identified. The method was successfully validated and enables rapid screening of samples subject to confirmatory analysis for the presence of TiO2 particles. For the latter, single-particle ICP-MS (spICP-MS) analysis after chemical extraction of the particles was used. The two methods establish a viable analytical strategy for assessing the absence of titania particles in food products on the EU market following the E 171 ban as a food additive.

10.
Nanomaterials (Basel) ; 13(18)2023 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-37764576

RESUMEN

Due to enhanced properties at the nanoscale, nanomaterials (NMs) have been incorporated into foods, food additives, and food packaging materials. Knowledge gaps related to (but not limited to) fate, transport, bioaccumulation, and toxicity of nanomaterials have led to an expedient need to expand research efforts in the food research field. While classical techniques can provide information on dilute suspensions, these techniques sample a low throughput of nanoparticles (NPs) in the suspension and are limited in the range of the measurement metrics so orthogonal techniques must be used in tandem to fill in measurement gaps. New and innovative characterization techniques have been developed and optimized for employment in food nano-characterization. Single particle inductively coupled plasma mass spectrometry, a high-throughput nanoparticle characterization technique capable of providing vital measurands of NP-containing samples such as size distribution, number concentration, and NP evolution has been employed as a characterization technique in food research since its inception. Here, we offer a short, critical review highlighting existing studies that employ spICP-MS in food research with a particular focus on method validation and trends in sample preparation and spICP-MS methodology. Importantly, we identify and address areas in research as well as offer insights into yet to be addressed knowledge gaps in methodology.

11.
Nanomaterials (Basel) ; 13(17)2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37686900

RESUMEN

This paper describes methodology based on the application of isotope dilution (ID) in single-particle inductively coupled plasma time-of-flight mass spectrometry (spICP-ToFMS) mode for the mass determination (and sizing) of silver nanoparticles (AgNPs). For this purpose, and considering that the analytical signal in spICP-MS shows a transient nature, an isotope dilution equation used for online work was adapted and used for the mass determination of individual NPs. The method proposed measures NP isotope ratios in a particle-to-particle approach, which allows for the characterization of NP mass (and size) distributions and not only the mean size of the distribution. For the best results to be obtained, our method development (undertaken through the analysis of the reference material NIST RM 8017) included the optimization of the working conditions for the best precision and accuracy in isotope ratios of individual NPs, which had been only reported to date with multicollector instruments. It is shown that the precision of the measurement of these ratios is limited by the magnitude of the signals obtained for each NP in the mass analyzer (counting statistics). However, the uncertainty obtained for the sizing of NPs in this approach can be improved by careful method optimization, where the most important parameters are shown to be the selection of the spike isotopic composition and concentration. Although only AgNPs were targeted in this study, the method presented, with the corresponding adaptations, could be applied to NPs of any other composition that include an element with different naturally available isotopes.

12.
Nanomaterials (Basel) ; 13(13)2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37446425

RESUMEN

In the present study, we addressed the knowledge gaps regarding the agglomeration behavior and fate of food-grade titanium dioxide (E 171) in human gastrointestinal digestion (GID). After thorough multi-technique physicochemical characterization including TEM, single-particle ICP-MS (spICP-MS), CLS, VSSA determination and ELS, the GI fate of E 171 was studied by applying the in vitro GID approach established for the regulatory risk assessment of nanomaterials in Europe, using a standardized international protocol. GI fate was investigated in fasted conditions, relevant to E 171 use in food supplements and medicines, and in fed conditions, with both a model food and E 171-containing food samples. TiO2 constituent particles were resistant to GI dissolution, and thus, their stability in lysosomal fluid was investigated. The biopersistence of the material in lysosomal fluid highlighted its potential for bioaccumulation. For characterizing the agglomeration degree in the small intestinal phase, spICP-MS represented an ideal analytical tool to overcome the limitations of earlier studies. We demonstrated that, after simulated GID, in the small intestine, E 171 (at concentrations reflecting human exposure) is present with a dispersion degree similar to that obtained when dispersing the material in water by means of high-energy sonication (i.e., ≥70% of particles <250 nm).

13.
Nanomaterials (Basel) ; 13(13)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37446474

RESUMEN

Single particle inductively coupled plasma mass spectrometry has been used for size measurements of individual nanoparticles (NPs). Here, uncertainties in size analysis based upon two calibration approaches were evaluated: (i) the use of particle size standard and (ii) the use of ion standard solution. For particle size standard approach, the source of uncertainty to determine the target NP diameter was related to the variation in the signal intensities of both target NPs and particle size standard, and the size distribution of the particle size standard. The relative uncertainties of the 50 nm silver NP as the target were 15.0%, 9.9%, and 10.8% when particle size standards of 30 nm, 60 nm, and 100 nm silver NPs were used, respectively. As for the ion standard solution approach, the sources of uncertainty were the concentration of working standard solution, sample flow rate, transport efficiency, slope of calibration curve, and variation in the signal intensity of the ion standard solution and of the target NPs. The relative uncertainties for the 50 nm silver NP were 18.5% for 1 ng/g, 7.6% for 10 ng/g, and 4.7% for 100 ng/g solutions. The lower uncertainty obtained with a high concentration working standard solution is recommended to improve precision on particle size determinations by spICP-MS.

14.
Nanomaterials (Basel) ; 13(12)2023 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-37368268

RESUMEN

This paper proposes a novel approach to implement an internal standard (IS) correction in single particle inductively coupled plasma mass spectrometry (SP ICP-MS), as exemplified for the characterization of Au nanoparticles (NPs) in complex matrices. This approach is based on the use of the mass spectrometer (quadrupole) in bandpass mode, enhancing the sensitivity for the monitoring of AuNPs while also allowing for the detection of PtNPs in the same measurement run, such that they can serve as an internal standard. The performance of the method developed was proved for three different matrices: pure water, a 5 g L-1 NaCl water solution, and another water solution containing 2.5% (m/v) tetramethylammonium hydroxide (TMAH)/0.1% Triton X-100. It was observed that matrix-effects impacted both the sensitivity of the NPs and their transport efficiencies. To circumvent this problem, two methods were used to determine the TE: the particle size method for sizing and the dynamic mass flow method for the determination of the particle number concentration (PNC). This fact, together with the use of the IS, enabled us to attain accurate results in all cases, both for sizing and for the PNC determination. Additionally, the use of the bandpass mode provides additional flexibility for this characterization, as it is possible to easily tune the sensitivity achieved for each NP type to ensure that their distributions are sufficiently resolved.

15.
Molecules ; 28(11)2023 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-37298916

RESUMEN

The regulation and characterization of nanomaterials in foods are of great interest due to the potential risks associated with their exposure and the increasing number of applications where they are used within the food industry. One factor limiting the scientifically rigorous regulation of nanoparticles in foods is the lack of standardized procedures for the extraction of nanoparticles (NPs) from complex matrices without alteration of their physico-chemical properties. To this end, we tested and optimized two sample preparation approaches (enzymatic- and alkaline-based hydrolyses) in order to extract 40 nm of Ag NP, following their equilibration with a fatty ground beef matrix. NPs were characterized using single particle inductively coupled plasma mass spectrometry (SP-ICP-MS). Fast sample processing times (<20 min) were achieved using ultrasonication to accelerate the matrix degradation. NP losses during the sample preparation were minimized by optimizing the choice of enzymes/chemicals, the use of surfactants, and the product concentration and sonication. The alkaline approach using TMAH (tetramethylammonium hydroxide) was found to have the highest recoveries (over 90%); however, processed samples were found to be less stable than the samples processed using an enzymatic digestion based upon pork pancreatin and lipase (≈60 % recovery). Low method detection limits (MDLs) of 4.8 × 106 particles g-1 with a size detection limit (SDL) of 10.9 nm were achieved for the enzymatic extraction whereas an MDL of 5.7 × 107 particles g-1 and an SDL of 10.5 nm were obtained for the alkaline hydrolysis.


Asunto(s)
Nanopartículas del Metal , Nanopartículas , Animales , Bovinos , Nanopartículas del Metal/química , Espectrometría de Masas/métodos , Plata/química , Análisis Espectral , Nanopartículas/química , Lipasa/química , Tamaño de la Partícula
16.
Mikrochim Acta ; 190(6): 204, 2023 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-37160774

RESUMEN

Extractions methods based on ultrapure water, tetramethylammonium hydroxide (TMAH), and tetrasodium pyrophosphate (TSPP) were applied to faeces collected from two in vivo experiments of pigs and chickens fed with a silver-based nanomaterial to study the fate and speciation of silver. For TMAH extraction, cysteine and CaCl2 were used to evaluate their stabilization effect on the silver forms. The analytical techniques single-particle inductively coupled plasma mass spectrometry (SP-ICP-MS), hydrodynamic chromatography hyphenated to ICP-MS (HDC-ICP-MS) and asymmetric flow field flow fractionation coupled to ICP-MS (AF4-ICP-MS) were applied to the simultaneous detection of particulate and dissolved silver. Results have shown that water extraction was a suitable option to assess the environmental release of silver, with percentages of 3 and 9% for faeces of pigs and chickens, respectively. The use of TMAH extraction combined with SP-ICP-MS analysis was useful to characterize Ag-containing particles (less than 1%). Both stabilizers, cysteine and CaCl2, have a similar effect on silver nanoparticle preservation for chicken faeces, whereas cysteine-Triton was better for pig samples. In any case, silver extraction efficiency with TMAH was low (39-42%) for both types of faeces due to a matrix effect. TSPP followed by ICP-MS enabled the fractionation of the silver in the faeces, with silver sulphide (41%) and ionic silver (62%) being the most abundant fractions.


Asunto(s)
Nanopartículas del Metal , Nanoestructuras , Animales , Porcinos , Cloruro de Calcio , Pollos , Cisteína , Plata , Heces
17.
Food Chem Toxicol ; 176: 113779, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37062331

RESUMEN

This study aims to provide information on the behaviour and biopersistence rate (BP) of metallic nanoparticles (Ag-NPs, TiO2-NPs, ZnO-NPs) naturally occurring in canned seafood and subjected to static in vitro digestion. Single particle ICP-MS analysis was performed to determine NPs distribution and concentrations in oral, gastric, and intestinal digests. Depending on the conditions of the digestive phase and the sample matrix, the phenomena of agglomeration and dispersion were highlighted and confirmed by Dynamic Light Scattering (DLS) technique. In standard suspensions, Ag-NPs had lower biopersistence (BP) than ZnO and TiO2-NPs (BP 34%, 89% and >100%, respectively). Among Ag-NPs and TiO2-NPs naturally present in the food matrix, those in canned tuna were more degradable than those in canned clam (BP Ag-NPs 36% vs. > 100%; BP TiO2-NPs 96% vs. > 100%), while BP ZnO-NPs showed high biopersistence in both seafood matrix (>100%). The biopersistence rates were higher than the recommended limit set by European Food Safety Authority (EFSA) (12%), referred to nanotechnologies to be applied in the food and feed chain, thus the investigated naturally occurring NPs cannot be considered readily degradable.


Asunto(s)
Nanopartículas del Metal , Nanopartículas , Óxido de Zinc , Humanos , Nanopartículas/análisis , Titanio , Alimentos Marinos/análisis , Tracto Gastrointestinal
18.
Environ Pollut ; 327: 121554, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37044251

RESUMEN

Long term exposure to particulate air pollution is known to increase respiratory morbidity and mortality. In urban areas with dense traffic most of these particles are generated by vehicles, via engine exhaust or wear processes. Non-exhaust particles come from wear processes such as those concerning brakes and their toxicity is little studied. To improve our understanding of the lung toxicity mechanisms of the nanometric fraction of brake wear nanoparticles (BWNPs), we studied whether these particles affect the barrier properties of the respiratory epithelium considering particle translocation, mucus production and repair efficiency. The Calu-3 cell line grown in two-compartment chambers was used to mimic the bronchial epithelial barrier. BWNPs detected by single-particle ICP-MS were shown to cross the epithelial tissue in small amounts without affecting the barrier integrity properties, because the permeability to Lucifer yellow was not increased and there was no cytotoxicity as assessed by the release of lactate-dehydrogenase. The interaction of BWNPs with the barrier did not induce a pro-inflammatory response, but increased the expression and production of MU5AC, a mucin, by a mechanism involving the epidermal growth factor receptor pathway. During a wound healing assay, BWNP-loaded cells exhibited the same ability to migrate, but those at the edge of the wound showed higher 5-ethynyl-2'-deoxyuridine incorporation, suggesting a higher proliferation rate. Altogether these results showed that BW. NPs do not exert overt cytotoxicity and inflammation but can translocate through the epithelial barrier in small amounts and increase mucus production, a key feature of acute inflammatory and chronic obstructive pulmonary diseases. Their loading in epithelial cells may impair the repair process through increased proliferation.


Asunto(s)
Contaminación del Aire , Nanopartículas , Células Epiteliales/metabolismo , Epitelio , Nanopartículas/toxicidad , Polvo
19.
Environ Sci Technol ; 57(18): 7263-7272, 2023 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-37104680

RESUMEN

Multiple analytical techniques to measure microplastics (MPs) in complex environmental matrices are currently under development, and which is most suited often depends on the aim(s) of the research question and the experimental design. Here, we further broaden the suite of possible techniques which can directly detect MPs in suspension while differentiating the carbon contained in MPs from other natural particles and dissolved organic carbon (DOC). Single particle inductively coupled plasma mass spectrometry (sp-ICP-MS) is well suited to measuring particles at trace concentrations, and the use of ICP time-of-flight-MS (ICP-TOFMS) allows one to simultaneously monitor the entire elemental spectrum to assess the full elemental composition of individual particles through developing elemental fingerprints. Because carbon is not detected in a standard operation mode with icp TOF, a dedicated optimization was necessary. Subsequently, to assess the feasibility of monitoring 12C particle pulses for the detection of MPs in more complex natural waters, two proof-of-principle studies were performed to measure MPs in waters with environmentally relevant DOC backgrounds (≤20 mg/L) and in the presence of other carbon containing particles, here, algae. Elevated DOC concentrations did not impact the enumeration of particles in suspension, and individual MPs, single algae, and aggregates of MPs and algae were clearly distinguished. The simultaneous identification of different analytes of interest allows for multiplexed sp-ICP-TOFMS experiments utilizing elemental fingerprinting of particles and is a step forward in quantifying MPs in aqueous environmental samples.


Asunto(s)
Microplásticos , Plásticos , Carbono , Análisis Espectral
20.
Anal Chim Acta ; 1240: 340756, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36641141

RESUMEN

To meet the demand for multi-element/isotope analysis at the single nanoparticle (NP) or cell level, different types of inductively coupled plasma mass spectroscopy (ICP-MS) have been used to simultaneously monitor multiple mass-to-charge ratios in single-particle/cell ICP-MS (SP/SC-ICP-MS) analysis. Systematic evaluation and comparison of the performance of these techniques are urgently required. Herein, three ICP-quadrupole (Q)-MS, two ICP-time of flight (TOF)-MS, and one multi-collector (MC)-ICP-MS instruments were employed to simultaneously detect 107Ag and 109Ag on single Ag NPs and Ag-exposed cyanobacteria cells. The evaluation was conducted by comparing the measured event-specific 109Ag:107Ag ratios with the natural ratio. Duration of NP or cell events and time resolution in the peak hopping mode were the main factors affecting the performance of ICP-Q-MS. Under the optimal condition (100 µs for both dwell time and settling time), less than 45% of the NP or cell events had a 109Ag:107Ag ratio deviating <30% from the natural ratio. Most events obtained via ICP-TOF-MS were paired events with both isotopes detected. For large-size NPs and cells with high exposure levels, nearly 80% of the events had a ratio deviation within ±30%. MC-ICP-MS performed particularly well in isotope determination with all the events having a ratio deviation within ±5%. For ICP-TOF-MS and MC-ICP-MS, the signal intensity of the events was the main factor affecting the accuracy of the measured 109Ag:107Ag ratios due to the counting statistics. The established methods and results provide insight on the analyses of two elements/isotopes or more on single NPs or cells. Based on the comparison of the advantages and limitations of these instruments, this study provides a critical reference for future multi-element/isotope SP/SC-ICP-MS analyses.


Asunto(s)
Nanopartículas , Espectrometría de Masas/métodos , Análisis Espectral , Isótopos
SELECCIÓN DE REFERENCIAS