Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Intervalo de año de publicación
1.
Rev. colomb. cardiol ; 29(supl.4): 38-41, dic. 2022. graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1423810

RESUMEN

Abstract We present the first case in Colombia of tricuspid endovascular valve in valve for failed bioprosthesis in a 40 years old patient with very high operative risk with great results, proposing kissing balloon annulus cracking technique as a practical solution for the colombian specialists.


Resumen Se presenta el primer caso en Colombia de un reemplazo percutáneo tipo válvula en válvula por falla de bioprótesis tricúspide en un paciente de 40 años con un muy alto riesgo quirúrgico, con excelentes resultados, proponiendo la técnica kissing balloon de fractura anular como una solución práctica para los especialistas colombianos.

2.
Rev. colomb. cardiol ; 29(5): 593-596, jul.-set. 2022. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1423786

RESUMEN

Abstract We present the first case in Colombia of tricuspid endovascular valve in valve for failed bioprosthesis in a 40-year-old patient with very high operative risk with great results, proposing kissing balloon annulus cracking technique as a practical solution for the Colombian specialists.


Resumen Presentamos el primer caso en Colombia de valve in valve tricúspideo para una bioprótesis deteriorada en una paciente de 40 años con muy alto riesgo quirúrgico con muy buenos resultados, y se propone la técnica de kissing balloon para ruptura anular como una solución practica para los especialistas en Colombia.

3.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;36(5): 703-706, Sept.-Oct. 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1351649

RESUMEN

Abstract Multivalve redo procedures carry a high surgical risk. We describe an alternative surgical treatment for patients presenting with severely degenerated aortic and mitral valve prostheses who have to undergo open surgery due to endocarditis. Open transcatheter multivalve implantation is a feasible bailout strategy in high-risk patients to save cross-clamp and procedural times to reduce morbidity and mortality.


Asunto(s)
Humanos , Bioprótesis , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Endocarditis/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Resultado del Tratamiento , Válvula Mitral/cirugía
4.
Braz J Cardiovasc Surg ; 36(5): 703-706, 2021 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-33577266

RESUMEN

Multivalve redo procedures carry a high surgical risk. We describe an alternative surgical treatment for patients presenting with severely degenerated aortic and mitral valve prostheses who have to undergo open surgery due to endocarditis. Open transcatheter multivalve implantation is a feasible bailout strategy in high-risk patients to save cross-clamp and procedural times to reduce morbidity and mortality.


Asunto(s)
Bioprótesis , Endocarditis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Endocarditis/cirugía , Humanos , Válvula Mitral/cirugía , Resultado del Tratamiento
5.
JACC Cardiovasc Interv ; 9(13): 1361-71, 2016 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-27388824

RESUMEN

OBJECTIVES: This study sought to evaluate the outcomes of the early experience of transcatheter mitral valve replacement (TMVR) with balloon-expandable valves in patients with severe mitral annular calcification (MAC) and reports the first large series from a multicenter global registry. BACKGROUND: The risk of surgical mitral valve replacement in patients with severe MAC is high. There are isolated reports of successful TMVR with balloon-expandable valves in this patient population. METHODS: We performed a multicenter retrospective review of clinical outcomes of patients with severe MAC undergoing TMVR. RESULTS: From September 2012 to July of 2015, 64 patients in 32 centers underwent TMVR with compassionate use of balloon-expandable valves. Mean age was 73 ± 13 years, 66% were female, and mean Society of Thoracic Surgeons score was 14.4 ± 9.5%. The mean mitral gradient was 11.45 ± 4.4 mm Hg and the mean mitral area was 1.18 ± 0.5 cm(2). SAPIEN valves (Edwards Lifesciences, Irvine, California) were used in 7.8%, SAPIEN XT in 59.4%, SAPIEN 3 in 28.1%, and Inovare (Braile Biomedica, Brazil) in 4.7%. Access was transatrial in 15.6%, transapical in 43.8%, and transseptal in 40.6%. Technical success according to Mitral Valve Academic Research Consortium criteria was achieved in 46 (72%) patients, primarily limited by the need for a second valve in 11 (17.2%). Six (9.3%) had left ventricular tract obstruction with hemodynamic compromise. Mean mitral gradient post-procedure was 4 ± 2.2 mm Hg, paravalvular regurgitation was mild or absent in all. Thirty-day all-cause mortality was 29.7% (cardiovascular = 12.5% and noncardiac = 17.2%); 84% of the survivors with follow-up data available were in New York Heart Association functional class I or II at 30 days (n = 25). CONCLUSIONS: TMVR with balloon-expandable valves in patients with severe MAC is feasible but may be associated with significant adverse events. This strategy might be an alternative for selected high-risk patients with limited treatment options.


Asunto(s)
Calcinosis/cirugía , Cateterismo Cardíaco/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Valvuloplastia con Balón , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Europa (Continente) , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , América del Norte , Selección de Paciente , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , América del Sur , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 82(6): E826-30, 2013 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-23613357

RESUMEN

Although transcatheter aortic valve replacement (TAVR) has been accepted as an attractive alternative for high-risk patients with severe symptomatic aortic stenosis (AS), patients with congenital bicuspid AS has been typically disqualified for this indication due to an implied risk of device dislocation, distortion, or device malfunctioning. Nonetheless, bicuspid AS is not uncommon and frequently missed by transthoracic echocardiography. We reported an interesting case of a high-risk patient with severe symptomatic bicuspid AS who underwent successful TAVR and discussed the anatomic requirements for a safe implant in patients with bicuspid AS considered candidates for TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/anomalías , Cateterismo Cardíaco/métodos , Arteria Femoral , Enfermedades de las Válvulas Cardíacas/terapia , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Aortografía , Enfermedad de la Válvula Aórtica Bicúspide , Cateterismo Cardíaco/instrumentación , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Tomografía Computarizada Multidetector , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA