Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Micromachines (Basel) ; 15(4)2024 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-38675362

RESUMEN

Using a stainless shadow mask combined with a magnetron-ion-assisted deposition (IAD) sputtering system, we investigate the surface morphologies and optical properties of microfilms. Optimal color-filter (CF) coating microfilms with niobium pent-oxide (Nb2O5)/silicon dioxide (SiO2) multilayers on a hard polycarbonate (HPC) substrate, grown at 85 °C and 50 SCCM oxygen flow, can obtain a fairly uniform thickness (with an average roughness of 0.083 and 0.106 nm respectively for Nb2O5 and SiO2 films) through all positions. On a flexible HPC substrate with the Nb2O5/SiO2 microfilms, meanwhile, the peak transmittances measured in the visible range are 95.70% and 91.47%, respectively, for coatings with and without a shadow mask for this new-tech system. For the optimal CF application with a shadow mask, transmittance on each 100 nm band-pass wavelength is enhanced by 4.04% absolute (blue), 2.96% absolute (green), and 2.12% absolute (red). Moreover, the developed new-tech system not only enhances the quality of the films by achieving smoother and uniform surfaces but also reduces deposition time, thereby improving overall process efficiency. For the with-shadow-mask condition, there is little shift at 50% transmittance (T50%), and high transmittance (~97%) is maintained after high-temperature (200 °C) baking for 12 h. These results are well above the commercial CF standard (larger than 90%) and demonstrate reliability and good durability for flexible optical applications.

2.
Ultrasonics ; 128: 106885, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36335828

RESUMEN

The article presents the results of numerical and experimental investigations of guided wave propagation in aluminum plates with variable thickness. The shapes of plate surfaces have been specially designed and manufactured using a CNC milling machine. The shapes of the plates were defined by sinusoidal functions varying in phase shift, which forced the changes in thickness variability alongside the propagation path. The main aim of the study is to analyze the wave propagation characteristics caused by non-uniform thickness. In the first step, the influence of thickness variability on the time course of propagating waves has been analyzed theoretically. The study proves that the wave propagation signals can be determined based on knowledge about the statistical description of the specimen geometry. The histograms of thickness distribution together with the a priori knowledge of the dispersion curves were used to develop an iterative procedure assuming that the signal from the previous step becomes the excitation in the next step. Such an approach allowed for taking into account the complex geometry of the plate and rejecting the assumption about the constant average thickness alongside the propagation path. In consequence, it was possible to predict correctly the signal time course, as well as the time of flight and number of propagating wave modes in specimens with variable thickness. It is demonstrated that theoretical signals predicted in this way coincide well with numerical and experimental results. Moreover, the novel procedure allowed for the correct prediction of the occurrence of higher-order modes.

3.
J Biomater Appl ; 37(3): 429-446, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35473434

RESUMEN

Conventional locking compression plate (LCP) made of non-biodegradable materials are well-known bone implants for internal fracture fixation because of their proven experimental success. LCP, however, is mechanically underpowered when made up of biodegradable materials (even with Mg-alloy). The biodegradable implant plate should not only exhibit adequate mechanical performance during implantation but also perform well after fracture, at least until complete healing of the fractured bone. With the aim of achieving enhanced mechanical performance, the design of the LCP has been modified to the design of Biodegradable Locking Compression Plate (BLCP) by adding a suitable thickness in the middle (only 4.6% of the total volume of the LCP), which may help retain some additional strength during implantation and after degradation. Both BLCP and LCP have been comparatively analyzed via FEM with the aid of axial compression and four-point bending tests. BLCP has a better mechanical capability of withstanding loads in its degraded form than in its non-degradable form. Furthermore, BLCP is up to 15.83% mechanically better in the non-degraded form as compared to LCP, which again becomes up to 100% more mechanically adequate in the degraded forms of BLCP than in LCP. BLCP is found safe for degradation up to 2 mm or 6 months with an estimated degradation rate of 4 mm/year, which may allow it to support fractured bone for at least the standard healing time. BLCP can be considered as a superior biodegradable bone implant plate after experimental assurance with the physiological environment and may replace LCP.


Asunto(s)
Implantes Absorbibles , Placas Óseas , Fenómenos Biomecánicos , Huesos , Fijación Interna de Fracturas , Presión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA