Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36.370
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39011510

RESUMEN

Objectives: Blister pack (BP) ingestion poses serious risks, such as gastrointestinal perforation, and accurate localization by computed tomography (CT) is a common practice. However, while it has been reported in vitro that CT visibility varies with the material type of BPs, there have been no reports on this variability in clinical settings. In this study, we investigated the CT detection rates of different BPs in clinical settings. Methods: This single-center retrospective study from 2010 to 2022 included patients who underwent endoscopic foreign body removal for BP ingestion. The patients were categorized into two groups for BP components, the polypropylene (PP) and the polyvinyl chloride (PVC)/polyvinylidene chloride (PVDC) groups. The primary outcome was the comparison of CT detection rates between the groups. We also evaluated whether the BPs contained tablets and analyzed their locations. Results: This study included 61 patients (15 in the PP group and 46 in the PVC/PVDC group). Detection rates were 97.8% for the PVC/PVDC group compared to 53.3% for the PP group, a significant difference (p < 0.01). No cases of BPs composed solely of PP were detected by CT. Blister packs were most commonly found in the upper thoracic esophagus. Conclusions: Even in a clinical setting, the detection rates of PVC and PVDC were higher than that of PP alone. Identifying PP without tablets has proven challenging in clinical. Considering the risk of perforation, these findings suggest that esophagogastroduodenoscopy may be necessary, even if CT detection is negative.

2.
Cureus ; 16(7): e63582, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39087177

RESUMEN

Background The fabrication of titanium carbide (Ti3C2)-cobalt sulfide (Co3S4)-based biosensors with high sensitivity and selectivity can change the biosensor manufacturing industry completely. Molecular and clinical diagnostics, disease progression monitoring, and drug discovery could utilize these sensors for early biomarker detection. MXene (Ti3C2) is a two-dimensional material with exceptional electrical conductivity, hydrophilicity, great thermal stability, large interlayer spacing, and a high surface area. Ti3C2's remarkable characteristics make it well-suited for biomolecule immobilization and target analyte detection. Co3S4 is a transition metal chalcogenide that has shown great potential in biosensors. Co3S4 nanoparticles (NPs) can potentially enhance Ti3C2 electrocatalytic activity, particularly in amino acid detection. L-arginine is a semi-essential amino acid, and the body frequently uses it to support healthy circulation and plays a crucial role in protein synthesis. We fabricated the Ti3C2-Co3S4 biosensor for L-arginine detection. Aim  This study aims to synthesize and apply Ti3C2-Co3S4 nanocomposites in amino acid biosensing. Materials and methods The Ti3C2 nanosheets were synthesized by the selective removal of an aluminum (Al) layer from the precursor (Ti3AlC2) using hydrofluoric acid (HF). The resulting mixture serves as an etchant, especially targeting the Al layers on Ti3AlC2 while protecting the desired MXene layers at room temperature. Cobalt nitrate hexahydrate was dissolved in deionized water. Sodium hydroxide was added to the cobalt solution and stirred. Thioacetamide was added to the above solution and stirred (Solution B). A mixture of Solution A and Solution B was stirred for 30 minutes. The mixture is transferred to a hydrothermal reactor and maintained at a temperature of 180°C for 12 hours. Once the reaction completes, we cool the resultant mixture to room temperature and then filter it using the washing technique. The sample underwent a 12-hour drying process at 80°C.  Results  This study investigated the use of a biosensor that employed Ti3C2-Co3S4 NPs to detect the concentration of L-arginine. The X-ray diffraction (XRD) shows clear and distinct peaks, which means that the synthesized Ti3C2-Co3S4 nanostructures have a crystalline structure. Scanning electron microscopy (SEM) analysis revealed that the sheetlike structure of synthesized Ti3C2-Co3S4 nanostructures revealed the crystalline morphology. The results of this study show that the Ti3C2-Co3S4 NP-based biosensor can be used to detect L-arginine in a sensitive and selective way. Conclusion  This study investigated the synthesis of Ti3C2-Co3S4 NPs and their ability to detect L-arginine levels and show a distinct correlation between the L-arginine concentration and the fluorescence intensity, demonstrating the biosensor's effectiveness in detecting L-arginine levels.

3.
J Synchrotron Radiat ; 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39088400

RESUMEN

Accurate analysis of the rich information contained within X-ray spectra usually calls for detailed electronic structure theory simulations. However, density functional theory (DFT), time-dependent DFT and many-body perturbation theory calculations increasingly require the use of advanced codes running on high-performance computing (HPC) facilities. Consequently, many researchers who would like to augment their experimental work with such simulations are hampered by the compounding of nontrivial knowledge requirements, specialist training and significant time investment. To this end, we present Web-CONEXS, an intuitive graphical web application for democratizing electronic structure theory simulations. Web-CONEXS generates and submits simulation workflows for theoretical X-ray absorption and X-ray emission spectroscopy to a remote computing cluster. In the present form, Web-CONEXS interfaces with three software packages: ORCA, FDMNES and Quantum ESPRESSO, and an extensive materials database courtesy of the Materials Project API. These software packages have been selected to model diverse materials and properties. Web-CONEXS has been conceived with the novice user in mind; job submission is limited to a subset of simulation parameters. This ensures that much of the simulation complexity is lifted and preliminary theoretical results are generated faster. Web-CONEXS can be leveraged to support beam time proposals and serve as a platform for preliminary analysis of experimental data.

4.
Spectrochim Acta A Mol Biomol Spectrosc ; 323: 124862, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39089067

RESUMEN

A series of promising luminescent materials, nonlinear optical crystals, and physiologically active compounds - aryl(oxy)(sulfanyl)(sulfonyl)acetates of guanidine (A) of unknown type was synthesized. Various functional groups present in (A) were identified using FTIR spectroscopy. 1H and 13C NMR spectral studies further confirm the molecular structure (A). Crystals of guanidinium 4-chlorophenyl(sulfanyl)acetate (1) and guanidinium 4-chlorophenyl(sulfonyl)acetate (2) were successfully grown. They belong to the same lowest symmetry category, but to different crystal systems: monoclinic (1) and orthorhombic (2). It has been established that intrinsic optical absorption begins at a wavelength of âˆ¼ 290 nm for crystalline compound (1) and âˆ¼ 335 nm for crystal (2). The intrinsic luminescence spectrum of crystal (1) includes two bands with maxima at 300 and 515 nm. In the intrinsic luminescence spectrum of crystal (2), only one band is observed with a maximum at 350 nm. Such luminescence in both crystals is excited in the intrinsic absorption bands, as well as by X-ray radiation. In addition, in the near ultraviolet and throughout the visible region, where optical absorption is not detected (it is very weak), low-inertia (less than 10 ns) rather intense luminescence of uncontrolled impurity-defect centers is excited. The spectral bands of optical absorption, photo- and X-ray luminescence discovered in experiments were systematized using a diagram of energy levels and quantum transitions in crystals and defect centers of the compounds under study.

5.
Comput Biol Med ; 180: 108922, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39089108

RESUMEN

BACKGROUND: Chest X-ray (CXR) is one of the most commonly performed imaging tests worldwide. Due to its wide usage, there is a growing need for automated and generalizable methods to accurately diagnose these images. Traditional methods for chest X-ray analysis often struggle with generalization across diverse datasets due to variations in imaging protocols, patient demographics, and the presence of overlapping anatomical structures. Therefore, there is a significant demand for advanced diagnostic tools that can consistently identify abnormalities across different patient populations and imaging settings. We propose a method that can provide a generalizable diagnosis of chest X-ray. METHOD: Our method utilizes an attention-guided decomposer network (ADSC) to extract disease maps from chest X-ray images. The ADSC employs one encoder and multiple decoders, incorporating a novel self-consistency loss to ensure consistent functionality across its modules. The attention-guided encoder captures salient features of abnormalities, while three distinct decoders generate a normal synthesized image, a disease map, and a reconstructed input image, respectively. A discriminator differentiates the real and the synthesized normal chest X-rays, enhancing the quality of generated images. The disease map along with the original chest X-ray image are fed to a DenseNet-121 classifier modified for multi-class classification of the input X-ray. RESULTS: Experimental results on multiple publicly available datasets demonstrate the effectiveness of our approach. For multi-class classification, we achieve up to a 3% improvement in AUROC score for certain abnormalities compared to the existing methods. For binary classification (normal versus abnormal), our method surpasses existing approaches across various datasets. In terms of generalizability, we train our model on one dataset and tested it on multiple datasets. The standard deviation of AUROC scores for different test datasets is calculated to measure the variability of performance across datasets. Our model exhibits superior generalization across datasets from diverse sources. CONCLUSIONS: Our model shows promising results for the generalizable diagnosis of chest X-rays. The impacts of using the attention mechanism and the self-consistency loss in our method are evident from the results. In the future, we plan to incorporate Explainable AI techniques to provide explanations for model decisions. Additionally, we aim to design data augmentation techniques to reduce class imbalance in our model.

6.
Radiologia (Engl Ed) ; 66(4): 326-339, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39089793

RESUMEN

INTRODUCTION: In recent years, systems that use artificial intelligence (AI) in medical imaging have been developed, such as the interpretation of chest X-ray to rule out pathology. This has produced an increase in systematic reviews (SR) published on this topic. This article aims to evaluate the methodological quality of SRs that use AI for the diagnosis of thoracic pathology by simple chest X-ray. MATERIAL AND METHODS: SRs evaluating the use of AI systems for the automatic reading of chest X-ray were selected. Searches were conducted (from inception to May 2022): PubMed, EMBASE, and the Cochrane Database of Systematic Reviews. Two investigators selected the reviews. From each SR, general, methodological and transparency characteristics were extracted. The PRISMA statement for diagnostic tests (PRISMA-DTA) and AMSTAR-2 were used. A narrative synthesis of the evidence was performed. Protocol registry: Open Science Framework: https://osf.io/4b6u2/. RESULTS: After applying the inclusion and exclusion criteria, 7 SRs were selected (mean of 36 included studies per review). All the included SRs evaluated "deep learning" systems in which chest X-ray was used for the diagnosis of infectious diseases. Only 2 (29%) SRs indicated the existence of a review protocol. None of the SRs specified the design of the included studies or provided a list of excluded studies with their justification. Six (86%) SRs mentioned the use of PRISMA or one of its extensions. The risk of bias assessment was performed in 4 (57%) SRs. One (14%) SR included studies with some validation of AI techniques. Five (71%) SRs presented results in favour of the diagnostic capacity of the intervention. All SRs were rated "critically low" following AMSTAR-2 criteria. CONCLUSIONS: The methodological quality of SRs that use AI systems in chest radiography can be improved. The lack of compliance in some items of the tools used means that the SRs published in this field must be interpreted with caution.


Asunto(s)
Inteligencia Artificial , Radiografía Torácica , Revisiones Sistemáticas como Asunto , Radiografía Torácica/métodos , Humanos
7.
Radiologia (Engl Ed) ; 66(4): 353-365, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39089795

RESUMEN

Thoracic surgical procedures are increasing in recent years, and there are different types of lung resections. Postsurgical complications vary depending on the type of resection and the time elapsed, with imaging techniques being key in the postoperative follow-up. Multidisciplinary management of these patients throughout the perioperative period is essential to ensure an optimal surgical outcome. This pictorial review will review the different thoracic surgical techniques, normal postoperative findings and postsurgical complications.


Asunto(s)
Complicaciones Posoperatorias , Humanos , Complicaciones Posoperatorias/diagnóstico por imagen , Procedimientos Quirúrgicos Torácicos/métodos , Radiografía Torácica
8.
Adv Sci (Weinh) ; : e2401236, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090836

RESUMEN

Anionic redox allows the direct formation of O─O bonds from lattice oxygens and provides higher catalytic in the oxygen evolution reaction (OER) than does the conventional metal ion mechanism. While previous theories have predicted and experiments have suggested the possible O─O bond, it has not yet been directly observed in the OER process. In this study, operando soft X-ray absorption spectroscopy (sXAS) at the O K-edge and the operando Raman spectra is performed on layered double CoFe hydroxides (LDHs) after intercalation with [Cr(C2O4)3]3-, and revealed a three-step oxidation process, staring from Co2+ to Co3+, further to Co4+ (3d6L), and ultimately leading to the formation of O─O bonds and O2 evolution above a threshold voltage (1.4 V). In contrast, a gradual oxidation of Fe is observed in CoFe LDHs. The OER activity exhibits a significant enhancement, with the overpotential decreasing from 300 to 248 mV at 10 mA cm-2, following the intercalation of [Cr(C2O4)3]3- into CoFe LDHs, underscoring a crucial role of anionic redox in facilitating water splitting.

9.
Angew Chem Int Ed Engl ; : e202407305, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090857

RESUMEN

Metal halide perovskite ferroelectrics combining spontaneous polarization and excellent semiconducting properties is an ideal platform for enabling self-driven X-ray detection, however, achievements to date have been only based on uniaxiality, which increases the complexity of device fabrication. Multi-axial ferroelectric materials have multiple equivalent polarization directions, making them potentially amenable to multi-axial self-driven X-ray detection, but the report on these types of materials is still a huge blank. Herein, a high-quality (BA)2(EA)2Pb3I10 (1) biaxial ferroelectric single crystal was successfully grown, which exhibited significant spontaneous polarization along the c-axis and b-axis. Under X-ray irradiation, bulk photovoltaic effect (BPVE) was exhibited along both the c-axis and b-axis, with open circuit voltages (Voc) of 0.23 V and 0.22 V, respectively. Then, the BPVE revealed along the inversion of polarized direction with the polarized electric fields. Intriguingly, due to the BPVE of 1, 1 achieved multi-axial self-driven X-ray detection for the first time (c-axis and b-axis) with relatively high sensitivities and ultralow detection limits (17.2 nGyair s-1 and 19.4 nGyair s-1, respectively). This work provides a reference for the subsequent use of multi-axial ferroelectricity for multi-axial self-driven optoelectronic detection.

10.
Artículo en Inglés | MEDLINE | ID: mdl-39098379

RESUMEN

BACKGROUND AND AIMS: DXA-measured visceral adipose tissue (VATDXA) is associated with adverse cardiometabolic risk profiles in cross-sectional studies, but longitudinal associations have not been investigated. We examined the longitudinal associations of baseline and change in VATDXA with future cardiometabolic risk in Australian participants of the Busselton Healthy Ageing study. METHODS AND RESULTS: We studied 3569 participants (54.7% female, aged 46-70 years) with data on VATDXA (GE Lunar Prodigy) and cardiometabolic risk factors at baseline and 6 years follow-up. The associations were examined using logistic and linear regression models, adjusting for baseline age and lifestyle factors. Mean baseline VATDXA mass was 1653 ± 880 g and 855 ± 580 g, and mean change in VATDXA +99 ± 500 g and +58 ± 312 g in males and females, respectively. Among all participants, 182 males (11.3%) and 197 females (10.1%) developed incident metabolic syndrome (MetS). Baseline VATDXA was associated with incident MetS with an adjusted odds ratio of 2.53 (95% CI: 2.03, 3.15) in males and 2.78 (2.30, 3.36) in females per SD increment. There was a graded positive association between longitudinal change in VATDXA and MetS severity z score in both sexes adjusted for baseline VAT (P < 0.001). All the above associations remained significant after further adjustment for baseline or change in BMI, waist circumference or waist-to-hip ratio in respective models (all P < 0.001). CONCLUSIONS: Higher baseline and greater longitudinal increase in VATDXA are independently associated with raised cardiometabolic risk over time, and may serve as useful markers for identifying middle-aged individuals at increased cardiometabolic risk.

11.
Ultrasound Med Biol ; 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39098471

RESUMEN

OBJECTIVE: Hip migration percentage (MP) measured on anteroposterior pelvis radiographs is the gold standard to assess the severity of hip displacement in children with cerebral palsy (CP). Repeated exposure of these children to ionizing radiation under a hip surveillance program is undesirable. Recently, a semi-automatic approach to measure MPUS on ultrasound (US) images was validated in a phantom study. This pilot in vivo study applied the previous phantom method and aimed to determine the reliability and accuracy of the MPUS. METHODS: Thirty-four children (23 boys and 11 girls) aged 8.9 ± 3.1 y old and diagnosed with CP were recruited. A total of 59 hips were scanned once, while 43 of these were scanned twice to evaluate the test-retest reliability. Two raters (R1 and R2) manually measured MPUS; procedures included selecting images of interest, cropping a region of interest and removing soft tissues on hip US images. Custom software was developed to measure MP automatically after the manual pre-image processing. RESULTS: The intra-class correlation coefficients (ICC2,1) for the test-retest (R1), intra-rater (R1) and inter-rater (R1 vs R2) reliabilities were 0.90, 0.94 and 0.82, respectively. The standard error of measurement of MPUS for all three evaluations was ≤3.0%. The mean absolute difference between MPUS and MPX-ray and the percentage of MPUS within clinical acceptance error of 10% for R1 and R2 were (R1: 6.2% ± 4.9%, 84.7%) and (R2: 7.6% ± 6.1%, 73.7%), respectively. CONCLUSION: This study demonstrated that US scans were repeatable and MPUS could be measured reliably and accurately.

12.
J Biol Chem ; : 107624, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39098532

RESUMEN

Human complement factor H (CFH) plays a central role in regulating activated C3b to protect host cells. CFH contain 20 short complement regulator (SCR) domains and eight N-glycosylation sites. The N-terminal SCR domains mediate C3b degradation while the C-terminal CFH domains bind to host cell surfaces to protect these. Our earlier study of Pichia-generated CFH fragments indicated a self-association site at SCR-17/18 that comprises a dimerization site for human factor H. Two N-linked glycans are located on SCR-17 and SCR-18. Here, when we expressed SCR-17/18 without glycans in an E. coli system, analytical ultracentrifugation showed that no dimers were now formed. To investigate this novel finding, full-length CFH and its C-terminal fragments were purified from human plasma and Pichia pastoris respectively, and their glycans were enzymatically removed using PNGase F. Using size-exclusion chromatography, mass spectrometry, and analytical ultracentrifugation, SCR-17/18 from Pichia showed notably less dimer formation without its glycans, confirming that the glycans are necessary for the formation of SCR-17/18 dimers. By surface plasmon resonance, affinity analyses interaction showed decreased binding of deglycosylated full-length CFH to immobilised C3b, showing that CFH glycosylation enhances the key CFH regulation of C3b. We conclude that our study revealed a significant new aspect of CFH regulation based on its glycosylation and its resulting dimerisation.

13.
Adv Sci (Weinh) ; : e2404348, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39099343

RESUMEN

Effective photoinduced charge transfer makes molecular bimetallic assemblies attractive for applications as active light-induced proton reduction systems. Developing competitive base metal dyads is mandatory for a more sustainable future. However, the electron transfer mechanisms from the photosensitizer to the proton reduction catalyst in base metal dyads remain so far unexplored. A Fe─Co dyad that exhibits photocatalytic H2 production activity is studied using femtosecond X-ray emission spectroscopy, complemented by ultrafast optical spectroscopy and theoretical time-dependent DFT calculations, to understand the electronic and structural dynamics after photoexcitation and during the subsequent charge transfer process from the FeII photosensitizer to the cobaloxime catalyst. This novel approach enables the simultaneous measurement of the transient X-ray emission at the iron and cobalt K-edges in a two-color experiment. With this methodology, the excited state dynamics are correlated to the electron transfer processes, and evidence of the Fe→Co electron transfer as an initial step of proton reduction activity is unraveled.

14.
Adv Mater ; : e2408777, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39101296

RESUMEN

Organic-inorganic hybrid manganese(II) halides (OIMnHs) have garnered tremendous interest across a wide array of research fields owing to their outstanding optical properties, abundant structural diversity, low-cost solution processibility, and low toxicity, which make them extremely suitable for use as a new class of luminescent materials for various optoelectronic applications. Over the past years, a plethora of OIMnHs with different structural dimensionalities and multifunctionalities such as efficient photoluminescence (PL), radioluminescence, circularly polarized luminescence, and mechanoluminescence have been newly created by judicious screening of the organic cations and inorganic Mn(II) polyhedra. Specifically, through precise molecular and structural engineering, a series of OIMnHs with near-unity PL quantum yields, high anti-thermal quenching properties, and excellent stability in harsh conditions have been devised and explored for applications in light-emitting diodes (LEDs), X-ray scintillators, multimodal anti-counterfeiting, and fluorescent sensing. In this review, the latest advancements in the development of OIMnHs as efficient light-emitting materials are summarized, which covers from their fundamental physicochemical properties to advanced optoelectronic applications, with an emphasis on the structural and functionality design especially for LEDs and X-ray detection and imaging. Current challenges and future efforts to unlock the potentials of these promising materials are also envisioned.

15.
Eur J Pediatr ; 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39096386

RESUMEN

Lung imaging techniques are crucial for managing ventilated patients in pediatric intensive care units (PICUs). Bedside chest x-ray has limitations such as low sensitivity and radiation exposure risks. Recently, lung ultrasound has emerged as a promising technology offering advantages such as real-time monitoring and radiation-free imaging. However, the integration of lung ultrasound into clinical practice raises questions about its impact on chest x-ray prescriptions. This study aims to assess whether implementing lung ultrasound reduces reliance on chest x-rays for ventilated pediatric patients in the PICU. This before-and-after uncontrolled quality improvement project was conducted from January 2022 to December 2023 in a referral PICU. The study included three phases: retrospective evaluation, learning phase, and prospective evaluation. Patients aged under 14 years, intubated, and ventilated for ≤ 30 days were included. Lung ultrasound was performed using a standardized protocol, and chest x-rays were conducted as per clinical indications. During the study period, 430 patients were admitted to the PICU, with 142 requiring mechanical ventilation. Implementation of routine bedside lung ultrasound led to a 39% reduction in chest x-ray requests (p < 0.001). Additionally, there was a significant decrease in irradiation exposure and a 27% reduction in costs associated with chest x-rays.Conclusion: Routine bedside lung ultrasound is a valuable tool in the modern PICU, it reduces the number of chest x-rays, with reduced radiation exposure and a potential cost savings. What is known: • Bedside chest x-ray is the main imaging study in ventilated pediatric patients • Chest x-ray is a valuable tool in pediatric critical care but it is associated with irradiation exposure What is new: • Implementation of bedside lung ultrasound in pediatric critical care unites reduces the chest x-rays requests and therefore patient-irradiation.

16.
Animal ; 18(8): 101241, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-39096597

RESUMEN

Skeleton bones, distinguished by trabecular and cortical bone tissue content, exhibit varied growth and composition, in response to modified dietary calcium and phosphorus levels. The study investigated how gilts adapt their individual bone and bone region mineralisation kinetics in response to changing intake of Ca and P. A total of 24 gilts were fed according to a two-phase (Depletion (D) 60-95 and Repletion (R) 95-140 kg BW, respectively). During the D phase, gilts were fed either 60% (D60) or 100% (D100) of the estimated P requirement. Subsequently, during the R phase, half of the gilts from each D diet were fed either 100% (R100) or 160% (R160) of the estimated P requirement according to a 2 × 2 factorial arrangement. Bone mineral content (BMC) was assessed in the whole body, individual bones (femur and lumbar spine L2-L4), and bone regions (head, front legs, trunk, pelvis, femur, and hind legs) every 2 weeks using dual-energy X-ray absorptiometry (DXA). At 95 kg BW, gilts fed D60 showed reduced BMC and BMC/BW ratio in all studied sites compared to those fed D100 (P < 0.001). During the depletion phase, the allometric BW-dependent regressions slopes for BMC of D100 gilts remained close to 1 for all sites and did not differ from each other. In contrast, the slopes were lower in D60 gilts (P < 0.05), with an 18% reduction in the whole body, except for the front and hind legs, femur, and pelvis, which exhibited higher reductions (P < 0.05). At 140 kg BW, BMC and BMC/BW ratio of all studied sites were similar in gilts previously fed D60 and D100, but higher in R160 than in R100 gilts (P < 0.05), except for front and hind legs. During the repletion phase, the allometric BW dependent regressions slopes for BMC were lower (P < 0.05) in R100 than in R160 gilts (for whole body -10%; P < 0.01) except for front and hind legs, femur, and pelvis. In conclusion, bone demineralisation and recovery followed similar trends for all measured body sites. However, the lumbar spine region was most sensitive whereas the hind legs were least sensitive. These data suggest that using bone regions such as the head and forelegs that can be collected easily at the slaughterhouse may be a viable alternative to whole body DXA measurement.

17.
J Econ Entomol ; 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39093635

RESUMEN

Radioisotope irradiators (using cesium-137 or cobalt-60) are used as sources of ionizing radiation to control quarantine or phytosanitary insect pests in internationally traded fresh commodities and to sterilize insects used in sterile insect release programs. There are institutional initiatives to replace isotopic irradiators (producing γ-rays) with lower-energy X-ray machines due to concerns about radiological terrorism and increasingly stringent regulations on the movement of radioisotopes. Questions remain about whether the biological effects of low-energy X-rays are comparable to those of γ-rays since differences in energy levels and dose rates of X-rays may have different efficacies. We compared adult emergence, flight ability, and adult survival in the Oriental fruit fly, Bactrocera dorsalis (Hendel) (Diptera: Tephritdae), after irradiation of third instar larvae with 100 kV or 5 MeV (5,000 kV) X-rays at 20 and 40 Gy in replicated studies. At 20 Gy, the adult emergence rate was significantly lower after irradiation with 100 kV compared to 5 MeV X-rays, suggesting higher efficacy at the lower energy level. In a follow-up study using 100 kV X-rays, applying 20 Gy using a slow dose rate (0.24 Gy min-1) resulted in significantly higher adult emergence than did a fast dose rate (3.3 Gy min-1), suggesting lower efficacy. Although our study suggests higher efficacy of low energy 100 kV X-rays, there is uncertainty in measuring the dose from an X-ray tube operating at 100 kV using an ionization chamber; we discuss how this uncertainty may change the interpretation of the results. Using a 100 kV X-ray irradiator to develop a phytosanitary treatment may underestimate the dose required for insect control using commercial high-energy γ-ray or X-ray systems.

18.
Appl Spectrosc ; : 37028241272257, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39094006

RESUMEN

In this study, a new system was developed to carry out simultaneous near-infrared (NIR) and small-angle X-ray scattering (SAXS) measurements. Aged PP was examined with the NIR-SAXS system to demonstrate how it can be utilized to derive pertinent information about polymer structure. Pairs of SAXS profiles and NIR spectra of PP in its initial state and after aging were measured to derive an in-depth understanding of the aging phenomenon. The SAXS profiles of the PP samples showed a clear shift of the SAXS peak to the lower q direction induced by the thermal aging, indicating an increase in the length of the long-period structure. Two-trace two-dimensional (2T2D) asynchronous correlation spectra derived from NIR spectra clearly revealed that the aging treatment leads to the substantial increase in the spectral intensity of the regularity bands representing the longer helix present in a folded lamellar structure. In other words, it suggest that the long helix structure is more abundantly present than the short helix structure in the aged PP than in the initial PP. By combining the information derived from the SAXS profiles and NIR spectra, the details of the aging-induced variation were clearly determined. Namely, aging causes additional crystallization of the PP by developing more helix structures, which involves an increase in lamellar thickness as well as a decrease in the amorphous region. The growth of the rigid crystalline phase restricts the elastic deformation in the amorphous structure, which eventually induces the deterioration of PP by making the polymer hard but brittle. Such observation, in turn, implies that the retarding or accelerating the crystallized structure of PP substantially works to control the progress of the aging.

19.
Eur Radiol Exp ; 8(1): 87, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090324

RESUMEN

BACKGROUND: Severe chronic obstructive pulmonary disease (COPD) often results in hyperinflation and flattening of the diaphragm. An automated computed tomography (CT)-based tool for quantifying diaphragm configuration, a biomarker for COPD, was developed in-house and tested in a large cohort of COPD patients. METHODS: We used the LungQ platform to extract the lung-diaphragm intersection, as direct diaphragm segmentation is challenging. The tool computed the diaphragm index (surface area/projected surface area) as a measure of diaphragm configuration on inspiratory scans in a COPDGene subcohort. Visual inspection of 250 randomly selected segmentations served as a quality check. Associations between the diaphragm index, Global Initiative for Chronic Obstructive Lung Disease (GOLD) stages, forced expiratory volume in 1 s (FEV1) % predicted, and CT-derived emphysema scores were explored using analysis of variance and Pearson correlation. RESULTS: The tool yielded incomplete segmentation in 9.2% (2.4% major defect, 6.8% minor defect) of 250 randomly selected cases. In 8431 COPDGene subjects (4240 healthy; 4191 COPD), the diaphragm index was increasingly lower with higher GOLD stages (never-smoked 1.83 ± 0.16; GOLD-0 1.79 ± 0.18; GOLD-1 1.71 ± 0.15; GOLD-2: 1.67 ± 0.16; GOLD-3 1.58 ± 0.14; GOLD-4 1.54 ± 0.11) (p < 0.001). Associations were found between the diaphragm index and both FEV1% predicted (r = 0.44, p < 0.001) and emphysema score (r = -0.36, p < 0.001). CONCLUSION: We developed an automated tool to quantify the diaphragm configuration in chest CT. The diaphragm index was associated with COPD severity, FEV1%predicted, and emphysema score. RELEVANCE STATEMENT: Due to the hypothesized relationship between diaphragm dysfunction and diaphragm configuration in COPD patients, automatic quantification of diaphragm configuration may prove useful in evaluating treatment efficacy in terms of lung volume reduction. KEY POINTS: Severe COPD changes diaphragm configuration to a flattened state, impeding function. An automated tool quantified diaphragm configuration on chest-CT providing a diaphragm index. The diaphragm index was correlated to COPD severity and may aid treatment assessment.


Asunto(s)
Diafragma , Enfermedad Pulmonar Obstructiva Crónica , Tomografía Computarizada por Rayos X , Humanos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Diafragma/diagnóstico por imagen , Diafragma/fisiopatología , Tomografía Computarizada por Rayos X/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Volumen Espiratorio Forzado
20.
Sci Rep ; 14(1): 17807, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39090344

RESUMEN

In recent years, a novel x-ray imaging modality has emerged that reveals unresolved sample microstructure via a "dark-field image", which provides complementary information to conventional "bright-field" images, such as attenuation and phase-contrast modalities. This x-ray dark-field signal is produced by unresolved microstructures scattering the x-ray beam resulting in localised image blur. Dark-field retrieval techniques extract this blur to reconstruct a dark-field image. Unfortunately, the presence of non-dark-field blur such as source-size blur or the detector point-spread-function can affect the dark-field retrieval as they also blur the experimental image. In addition, dark-field images can be degraded by the artefacts induced by large intensity gradients from attenuation and propagation-based phase contrast, particularly around sample edges. By measuring any non-dark-field blurring across the image plane and removing it from experimental images, as well as removing attenuation and propagation-based phase contrast, we show that a directional dark-field image can be retrieved with fewer artefacts and more consistent quantitative measures. We present the details of these corrections and provide "before and after" directional dark-field images of samples imaged at a synchrotron source. This paper utilises single-grid directional dark-field imaging, but these corrections have the potential to be broadly applied to other x-ray imaging techniques.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA