Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.559
Filtrar
1.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730404

RESUMEN

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Asunto(s)
Fibrilación Atrial , Bradicardia , Estimulación Cardíaca Artificial , Ablación por Catéter , Frecuencia Cardíaca , Marcapaso Artificial , Recurrencia , Humanos , Masculino , Femenino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Fibrilación Atrial/cirugía , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Factores de Tiempo , Factores de Riesgo , Síndrome , Taquicardia/fisiopatología , Taquicardia/diagnóstico , Taquicardia/terapia , Taquicardia/cirugía
3.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38647070

RESUMEN

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Técnicas de Sutura , Humanos , Fibrilación Atrial/cirugía , Femenino , Masculino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios Prospectivos , Venas Pulmonares/cirugía , Técnicas de Sutura/efectos adversos , Anciano , Resultado del Tratamiento , Alemania , Factores de Tiempo , Dispositivos de Cierre Vascular , Ambulación Precoz , Técnicas Hemostáticas/instrumentación
4.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584394

RESUMEN

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cardioversión Eléctrica/efectos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
5.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584395

RESUMEN

AIMS: A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS: A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION: The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Estudios Prospectivos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Catéteres , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fenómenos Magnéticos , Recurrencia
6.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38588039

RESUMEN

AIMS: Phrenic nerve injury (PNI) is the most common complication during cryoballoon ablation. Currently, two cryoballoon systems are available, yet the difference is unclear. We sought to compare the acute procedural efficacy and safety of the two cryoballoons. METHODS: This prospective observational study consisted of 2,555 consecutive atrial fibrillation (AF) patients undergoing pulmonary vein isolation (PVI) using either conventional (Arctic Front Advance) (AFA-CB) or novel cryoballoons (POLARx) (POLARx-CB) at 19 centers between January 2022 and October 2023. RESULTS: Among 2,555 patients (68.8 ± 10.9 years, 1,740 men, paroxysmal AF[PAF] 1,670 patients), PVIs were performed by the AFA-CB and POLARx-CB in 1,358 and 1,197 patients, respectively. Touch-up ablation was required in 299(11.7%) patients. The touch-up rate was significantly lower for POLARx-CB than AFA-CB (9.5% vs. 13.6%, p = 0.002), especially for right inferior PVs (RIPVs). The touch-up rate was significantly lower for PAF than non-PAF (8.8% vs. 17.2%, P < 0.001) and was similar between the two cryoballoons in non-PAF patients. Right PNI occurred in 64(2.5%) patients and 22(0.9%) were symptomatic. It occurred during the right superior PV (RSPV) ablation in 39(1.5%) patients. The incidence was significantly higher for POLARx-CB than AFA-CB (3.8% vs. 1.3%, P < 0.001) as was the incidence of symptomatic PNI (1.7% vs. 0.1%, P < 0.001). The difference was significant during RSPV (2.5% vs. 0.7%, P < 0.001) but not RIPV ablation. The PNI recovered more quickly for the AFA-CB than POLARx-CB. CONCLUSIONS: Our study demonstrated a significantly higher incidence of right PNI and lower touch-up rate for the POLARx-CB than AFA-CB in the real-world clinical practice.


Asunto(s)
Fibrilación Atrial , Criocirugía , Traumatismos de los Nervios Periféricos , Nervio Frénico , Venas Pulmonares , Sistema de Registros , Humanos , Nervio Frénico/lesiones , Masculino , Femenino , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Venas Pulmonares/cirugía , Anciano , Criocirugía/efectos adversos , Criocirugía/métodos , Estudios Prospectivos , Incidencia , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/prevención & control , Persona de Mediana Edad , Resultado del Tratamiento , Ablación por Catéter/efectos adversos
7.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38582974

RESUMEN

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Criocirugía , Taquicardia Ventricular , Anciano , Humanos , Persona de Mediana Edad , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/cirugía , Ablación por Catéter/efectos adversos , Cicatriz/complicaciones , Criocirugía/efectos adversos , Estudios Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía , Temperatura , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584521

RESUMEN

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Enfermedad Iatrogénica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Ablación por Catéter/efectos adversos , Falla de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Lesiones Cardíacas/etiología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/terapia , Agujas , Función Ventricular Izquierda , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/terapia , Oclusión Coronaria/fisiopatología , Angiografía Coronaria
9.
J Am Heart Assoc ; 13(8): e033740, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38597139

RESUMEN

BACKGROUND: Periodontitis has not been recognized as a modifiable risk factor for atrial fibrillation (AF). This prospective nonrandomized study investigated whether periodontal treatment improves the AF ablation outcome. METHODS AND RESULTS: We prospectively enrolled 288 AF patients scheduled to undergo initial radiofrequency catheter ablation. Each patient underwent periodontal inflamed surface area (PISA; a quantitative index of periodontal inflammation) measurement. All eligible patients were recommended to receive periodontal treatment within the blanking period, and 97 consented. During the mean follow-up period of 507±256 days, 70 (24%) AF recurrences were documented. Patients who exhibited AF recurrences had a higher PISA than those who did not (456.8±403.5 versus 277.7±259.0 mm2, P=0.001). These patients were categorized into high-PISA (>615 mm2) and low-PISA (<615 mm2) groups according to the receiver operating characteristic analysis for AF recurrence (area under the curve, 0.611; sensitivity, 39%; specificity, 89%). A high PISA, as well as female sex, AF duration, and left atrial volume, were the statistically significant predicter for AF recurrence (hazard ratio [HR], 2.308 [95% CI, 1.234-4.315]; P=0.009). In patients with a high PISA, those who underwent periodontal treatment showed significantly fewer AF recurrences (P=0.01, log-rank test). The adjusted HR of periodontal treatment for AF recurrence was 0.393 (95% CI, 0.215-0.719; P=0.002). CONCLUSIONS: Periodontitis may serve as a modifiable risk factor for AF. PISA is a hallmark of AF recurrence, and periodontal treatment improves the AF ablation outcome, especially for those with poor periodontal condition.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Periodontitis , Humanos , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Estudios Prospectivos , Atrios Cardíacos , Ablación por Catéter/efectos adversos , Recurrencia , Resultado del Tratamiento
10.
Skin Res Technol ; 30(4): e13652, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38572582

RESUMEN

OBJECTIVE: To investigate whether compression therapy after thermal ablation of varicose veins can improve the prognosis of patients. METHODS: Systematic research were applied for Chinese and English electronic databases(PubMed, Web of Science, Cochrane Library, CNKI, Wanfang, VIP Databases). Eligible prospective studies that comparing the efficacy of compression therapy and non-compression therapy on patients after thermal ablation of varicose veins were included. The interest outcome such as pain, quality of life (QOL), venous clinical severity score (VCSS), time to return to work and complications were analyzed. RESULTS: 10 studies were of high quality, and randomized controlled trials involving 1,545 patients met the inclusion criteria for this study. At the same time, the meta-analysis showed that the application of compression therapy improved pain (SMD: -0.51, 95% CI: -0.95, -0.07) but exhibited no statistically significant effect on QOL (SMD: 0.04, 95% CI: -0.08, 0.16), VCSS (MD: -0.05, 95% CI: -1.19, 1.09), time to return to work (MD: -0.43, 95% CI: -0.90, 0.03), total complications (RR: 0.54, 95% CI: 0.27, 1.09), and thrombosis (RR: 0.71, 95% CI: 0.31, 1.62). CONCLUSION: Compression therapy after thermal ablation of varicose veins can slightly relieve pain, but it has not been found to be associated with improvement in other outcomes.


Asunto(s)
Ablación por Catéter , Terapia por Láser , Várices , Humanos , Calidad de Vida , Estudios Prospectivos , Terapia por Láser/métodos , Várices/cirugía , Várices/etiología , Dolor/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto
11.
PLoS One ; 19(4): e0301753, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38578782

RESUMEN

BACKGROUND: Atrial arrhythmias (AA) commonly affect patients with cardiac amyloidosis (CA) and are a contributing risk factor for the development of heart failure (HF). This study sought to investigate the long-term efficacy and impact of catheter ablation on HF progression in patients with CA and AA. METHODS: Thirty-one patients with CA and AA undergoing catheter ablation were retrospectively included (transthyretin-ATTR CA 61% and light chain-AL CA 39%). AA subtypes included atrial fibrillation (AFib) in 22 (paroxysmal in 10 and persistent in 12), atrial flutter (AFl) in 17 and atrial tachycardia (AT) in 11 patients. Long-term AA recurrence rates were evaluated along with the impact of sinus rhythm (SR) maintenance on HF and mortality. RESULTS: AA recurrence was observed in 14 patients (45%) at a median of 3.5 months (AFib n = 8, AT n = 6, AFl = 0). Post-cardioversion, medical therapy or catheter ablation, 10 patients (32%) remained in permanent AA. Over a median follow-up of 19 months, all-cause mortality was 39% (n = 12): 3 with end-stage HF, 5 due to late complications of CA, 1 sudden cardiac death, 1 stroke, 1 COVID 19 (and one unknown). With maintenance of SR following catheter ablation, significant reductions in serum creatinine and natriuretic peptide levels were observed with improvements in NYHA class. Two patients required hospitalization for HF in the SR maintenance cohort compared to 5 patients in the AA recurrence cohort (p = 0.1). All 3 patients with deaths secondary to HF had AA recurrence compared to 11 out of the 28 patients whom were long-term survivors or deaths not related to HF (p = 0.04). All-cause mortality was not associated with AA recurrence. CONCLUSION: This study demonstrates moderate long-term efficacy of SR maintenance with catheter ablation for AA in patients with CA. Improvements in clinical and biological status with positive trends in HF mortality are observed if SR can be maintained.


Asunto(s)
Amiloidosis , Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Supraventricular , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Recurrencia Local de Neoplasia/cirugía , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Amiloidosis/complicaciones , Amiloidosis/cirugía , Ablación por Catéter/efectos adversos
12.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38597211

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Femenino , Humanos , Persona de Mediana Edad , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Venas Pulmonares/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Fenotipo , Recurrencia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
13.
Cardiovasc Diabetol ; 23(1): 121, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38581024

RESUMEN

BACKGROUND: This study investigates the relationship between triglyceride-glucose (TyG) index trajectories and the results of ablation in patients with stage 3D atrial fibrillation (AF). METHODS: A retrospective cohort study was carried out on patients who underwent AF Radiofrequency Catheter Ablation (RFCA) at the Cardiology Department of the Fourth Affiliated Hospital of Zhejiang University and Taizhou Hospital of Zhejiang Province from January 2016 to December 2022. The main clinical endpoint was determined as the occurrence of atrial arrhythmia for at least 30 s following a 3-month period after ablation. Using a latent class trajectory model, different trajectory groups were identified based on TyG levels. The relationship between TyG trajectory and the outcome of AF recurrence in patients was assessed through Kaplan-Meier survival curve analysis and multivariable Cox proportional hazards regression model. RESULTS: The study included 997 participants, with an average age of 63.21 ± 9.84 years, of whom 630 were males (63.19%). The mean follow-up period for the participants was 30.43 ± 17.75 months, during which 200 individuals experienced AF recurrence. Utilizing the minimum Bayesian Information Criterion (BIC) and the maximum Entropy principle, TyG levels post-AF RFCA were divided into three groups: Locus 1 low-low group (n = 791), Locus 2 low-high-low group (n = 14), and Locus 3 high-high group (n = 192). Significant differences in survival rates among the different trajectories were observed through the Kaplan-Meier curve (P < 0.001). Multivariate Cox regression analysis showed a significant association between baseline TyG level and AF recurrence outcomes (HR = 1.255, 95% CI: 1.087-1.448). Patients with TyG levels above 9.37 had a higher risk of adverse outcomes compared to those with levels below 8.67 (HR = 2.056, 95% CI: 1.335-3.166). Furthermore, individuals in Locus 3 had a higher incidence of outcomes compared to those in Locus 1 (HR = 1.580, 95% CI: 1.146-2). CONCLUSION: The TyG trajectories in patients with stage 3D AF are significantly linked to the outcomes of AF recurrence. Continuous monitoring of TyG levels during follow-up may help in identifying patients at high risk of AF recurrence, enabling the early application of effective interventions.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Estudios Retrospectivos , Teorema de Bayes , Resultado del Tratamiento , Factores de Riesgo , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
15.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38587017

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , América Latina , Resultado del Tratamiento , Catéteres , Asia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
17.
Medicine (Baltimore) ; 103(14): e37723, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38579029

RESUMEN

INTRODUCTION: Transseptal punctures (TSPs) are widely used in left atrium and left ventricle surgery. Accidental puncture of the puncture needle into the aorta is a rare complication that is rarely reported but has serious consequences. The appropriate management of this complication remains unclear. PATIENT CONCERNS: This report describes a case of a male with the chief complaint: paroxysmal palpitation for 1 year, aggravated for 1 month. DIAGNOSIS: The electrophysiological diagnosis was atrioventricular reentrant tachycardia caused by left-side bypass. INTERVENTIONS: Radiofrequency ablation of the heart was a necessary treatment and a TSP operation was needed, in which a puncture was mistakenly believed to have entered the aorta, a series of measures were taken urgently. Although the surgical procedure in this case was a false alarm, we still initiated a series of emergency plans. Emergency measures to address the complications were effectively implemented, and the emergency measures were promptly terminated after it was clear that complications had been misjudged. OUTCOMES: At last, it was confirmed that the angiogram was a pulmonary artery image, not an aorta image. Then the atrial septal puncture operation was successfully completed, and under the guidance of the Carto system, the ablation was successfully completed. Postoperative fluoroscopy showed no complications, such as pericardial effusion. After 2 years of follow-up, there was no reoccurrence of tachycardia, and there were no complications. It is crucial that emergency procedures are terminated in a timely manner after a clear miscarriage of performance. Although accidental puncture into the aorta is urgent and serious, performing a blockage or even thoracotomy in an emergency if complications are not clearly confirmed can cause further damage to the patient and would be a definitively wrong strategy. CONCLUSION: Strict and standardized TSP operations can avoid complications. Correct judgment of the authenticity of complications is crucial, and remedial measures that may cause further damage should not be blindly adopted. The retention of the aortic guide wire can provide convenient access for further differential diagnosis and remedial treatment.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Defectos del Tabique Interatrial , Ablación por Radiofrecuencia , Humanos , Masculino , Aorta/cirugía , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Defectos del Tabique Interatrial/cirugía , Punciones/efectos adversos , Punciones/métodos , Resultado del Tratamiento
18.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38607938

RESUMEN

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Recurrencia , Sistema de Registros , Reoperación , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Anciano , Factores de Tiempo , Suiza/epidemiología , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos
19.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38646922

RESUMEN

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Esófago , Traumatismos del Nervio Vago , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Masculino , Femenino , Esófago/lesiones , Esófago/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Estudios Prospectivos , Persona de Mediana Edad , Traumatismos del Nervio Vago/etiología , Traumatismos del Nervio Vago/epidemiología , Incidencia , Anciano , Aprendizaje Automático , Factores de Riesgo , Alemania/epidemiología , Quemaduras/epidemiología , Quemaduras/etiología , Factores de Tiempo , Resultado del Tratamiento , Venas Pulmonares/cirugía , Nervio Vago
20.
J Am Heart Assoc ; 13(9): e031795, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38664237

RESUMEN

BACKGROUND: Transcatheter renal denervation (RDN) has had inconsistent efficacy and concerns for durability of denervation. We aimed to investigate long-term safety and efficacy of transcatheter microwave RDN in vivo in normotensive sheep in comparison to conventional radiofrequency ablation. METHODS AND RESULTS: Sheep underwent bilateral RDN, receiving 1 to 2 microwave ablations (maximum power of 80-120 W for 240 s-480 s) and 12 to 16 radiofrequency ablations (180 s-240 s) in the main renal artery in a paired fashion, alternating the side of treatment, euthanized at 2 weeks (acute N=15) or 5.5 months (chronic N=15), and compared with undenervated controls (N=4). Microwave RDN produced substantial circumferential perivascular injury compared with radiofrequency at both 2 weeks [area 239.8 (interquartile range [IQR] 152.0-343.4) mm2 versus 50.1 (IQR, 32.0-74.6) mm2, P <0.001; depth 16.4 (IQR, 13.9-18.9) mm versus 7.5 (IQR, 6.0-8.9) mm P <0.001] and 5.5 months [area 20.0 (IQR, 3.4-31.8) mm2 versus 5.0 (IQR, 1.4-7.3) mm2, P=0.025; depth 5.9 (IQR, 1.9-8.8) mm versus 3.1 (IQR, 1.2-4.1) mm, P=0.005] using mixed models. Renal denervation resulted in significant long-term reductions in viability of renal sympathetic nerves [58.9% reduction with microwave (P=0.01) and 45% reduction with radiofrequency (P=0.017)] and median cortical norepinephrine levels [71% reduction with microwave (P <0.001) and 72.9% reduction with radiofrequency (P <0.001)] at 5.5 months compared with undenervated controls. CONCLUSIONS: Transcatheter microwave RDN produces deep circumferential perivascular ablations without significant arterial injury to provide effective and durable RDN at 5.5 months compared with radiofrequency RDN.


Asunto(s)
Riñón , Microondas , Arteria Renal , Simpatectomía , Animales , Microondas/uso terapéutico , Microondas/efectos adversos , Simpatectomía/métodos , Simpatectomía/efectos adversos , Arteria Renal/inervación , Riñón/inervación , Riñón/irrigación sanguínea , Ovinos , Ablación por Catéter/métodos , Ablación por Catéter/efectos adversos , Factores de Tiempo , Modelos Animales de Enfermedad , Presión Sanguínea/fisiología , Femenino , Ablación por Radiofrecuencia/métodos , Ablación por Radiofrecuencia/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...