Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.715
Filtrar
1.
Aging Clin Exp Res ; 36(1): 108, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717552

RESUMEN

INTRODUCTION: Wrist-worn activity monitors have seen widespread adoption in recent times, particularly in young and sport-oriented cohorts, while their usage among older adults has remained relatively low. The main limitations are in regards to the lack of medical insights that current mainstream activity trackers can provide to older subjects. One of the most important research areas under investigation currently is the possibility of extrapolating clinical information from these wearable devices. METHODS: The research question of this study is understanding whether accelerometry data collected for 7-days in free-living environments using a consumer-based wristband device, in conjunction with data-driven machine learning algorithms, is able to predict hand grip strength and possible conditions categorized by hand grip strength in a general population consisting of middle-aged and older adults. RESULTS: The results of the regression analysis reveal that the performance of the developed models is notably superior to a simple mean-predicting dummy regressor. While the improvement in absolute terms may appear modest, the mean absolute error (6.32 kg for males and 4.53 kg for females) falls within the range considered sufficiently accurate for grip strength estimation. The classification models, instead, excel in categorizing individuals as frail/pre-frail, or healthy, depending on the T-score levels applied for frailty/pre-frailty definition. While cut-off values for frailty vary, the results suggest that the models can moderately detect characteristics associated with frailty (AUC-ROC: 0.70 for males, and 0.76 for females) and viably detect characteristics associated with frailty/pre-frailty (AUC-ROC: 0.86 for males, and 0.87 for females). CONCLUSIONS: The results of this study can enable the adoption of wearable devices as an efficient tool for clinical assessment in older adults with multimorbidities, improving and advancing integrated care, diagnosis and early screening of a number of widespread diseases.


Asunto(s)
Acelerometría , Fuerza de la Mano , Muñeca , Humanos , Fuerza de la Mano/fisiología , Masculino , Femenino , Anciano , Acelerometría/instrumentación , Acelerometría/métodos , Persona de Mediana Edad , Muñeca/fisiología , Dispositivos Electrónicos Vestibles , Anciano de 80 o más Años , Aprendizaje Automático
2.
Int J Health Geogr ; 23(1): 12, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745292

RESUMEN

BACKGROUND: Previous research indicates the start of primary school (4-5-year-old) as an essential period for the development of children's physical activity (PA) patterns, as from this point, the age-related decline of PA is most often observed. During this period, young children are exposed to a wider variety of environmental- and social contexts and therefore their PA is influenced by more diverse factors. However, in order to understand children's daily PA patterns and identify relevant opportunities for PA promotion, it is important to further unravel in which (social) contexts throughout the day, PA of young children takes place. METHODS: We included a cross-national sample of 21 primary schools from the Startvaardig study. In total, 248 children provided valid accelerometer and global positioning (GPS) data. Geospatial analyses were conducted to quantify PA in (social) environments based on their school and home. Transport-related PA was evaluated using GPS speed-algorithms. PA was analysed at different environments, time-periods and for week- and weekend days separately. RESULTS: Children accumulated an average of 60 min of moderate-to-vigorous PA (MVPA), both during week- and weekend days. Schools contributed to approximately half of daily MVPA during weekdays. During weekends, environments within 100 m from home were important, as well as locations outside the home-school neighbourhood. Pedestrian trips contributed to almost half of the daily MVPA. CONCLUSIONS: We identified several social contexts relevant for children's daily MVPA. Schools have the potential to significantly contribute to young children's PA patterns and are therefore encouraged to systematically evaluate and implement parts of the school-system that stimulate PA and potentially also learning processes. Pedestrian trips also have substantial contribution to daily MVPA of young children, which highlights the importance of daily active transport in school- and parental routines.


Asunto(s)
Ejercicio Físico , Instituciones Académicas , Humanos , Ejercicio Físico/fisiología , Preescolar , Masculino , Femenino , Acelerometría/métodos , Sistemas de Información Geográfica , Factores de Tiempo , Italia/epidemiología , Estudios Transversales
3.
PLoS One ; 19(5): e0299943, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38701085

RESUMEN

Spending time outdoors is associated with increased time spent in physical activity, lower chronic disease risk, and wellbeing. Many studies rely on self-reported measures, which are prone to recall bias. Other methods rely on features and functions only available in some GPS devices. Thus, a reliable and versatile method to objectively quantify time spent outdoors is needed. This study sought to develop a versatile method to classify indoor and outdoor (I/O) GPS data that can be widely applied using most types of GPS and accelerometer devices. To develop and test the method, five university students wore an accelerometer (ActiGraph wGT3X-BT) and a GPS device (Canmore GT-730FL-S) on an elastic belt at the right hip for two hours in June 2022 and logged their activity mode, setting, and start time via activity diaries. GPS trackers were set to collect data every 5 seconds. A rule-based point cluster-based method was developed to identify indoor, outdoor, and in-vehicle time. Point clusters were detected using an application called GPSAS_Destinations and classification were done in R using accelerometer lux, building footprint, and park location data. Classification results were compared with the submitted activity diaries for validation. A total of 7,006 points for all participants were used for I/O classification analyses. The overall I/O GPS classification accuracy rate was 89.58% (Kappa = 0.78), indicating good classification accuracy. This method provides reliable I/O clarification results and can be widely applied using most types of GPS and accelerometer devices.


Asunto(s)
Acelerometría , Ejercicio Físico , Sistemas de Información Geográfica , Humanos , Sistemas de Información Geográfica/instrumentación , Acelerometría/instrumentación , Acelerometría/métodos , Masculino , Femenino , Ejercicio Físico/fisiología , Adulto Joven , Adulto , Factores de Tiempo
4.
PLoS One ; 19(5): e0290912, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739600

RESUMEN

This cross-sectional study aimed to identify and validate cut-points for measuring physical activity using Axivity AX6 accelerometers positioned at the shank in older adults. Free-living physical activity was assessed in 35 adults aged 55 and older, where each participant wore a shank-mounted Axivity and a waist-mounted ActiGraph simultaneously for 72 hours. Optimized cut-points for each participant's Axivity data were determined using an optimization algorithm to align with ActiGraph results. To assess the validity between the physical activity assessments from the optimized Axivity cut-points, a leave-one-out cross-validation was conducted. Bland-Altman plots with 95% limits of agreement, intraclass correlation coefficients (ICC), and mean differences were used for comparing the systems. The results indicated good agreement between the two accelerometers when classifying sedentary behaviour (ICC = 0.85) and light physical activity (ICC = 0.80), and moderate agreement when classifying moderate physical activity (ICC = 0.67) and vigorous physical activity (ICC = 0.70). Upon removal of a significant outlier, the agreement was slightly improved for sedentary behaviour (ICC = 0.86) and light physical activity (ICC = 0.82), but substantially improved for moderate physical activity (ICC = 0.81) and vigorous physical activity (ICC = 0.96). Overall, the study successfully demonstrated the capability of the resultant cut-point model to accurately classify physical activity using Axivity AX6 sensors placed at the shank.


Asunto(s)
Acelerometría , Ejercicio Físico , Humanos , Anciano , Masculino , Femenino , Acelerometría/instrumentación , Acelerometría/métodos , Ejercicio Físico/fisiología , Persona de Mediana Edad , Estudios Transversales , Conducta Sedentaria
5.
Sensors (Basel) ; 24(8)2024 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-38676029

RESUMEN

The increasing use of inertial measurement units (IMU) in biomedical sciences brings new possibilities for clinical research. The aim of this paper is to demonstrate the accuracy of the IMU-based wearable Syde® device, which allows day-long and remote continuous gait recording in comparison to a reference motion capture system. Twelve healthy subjects (age: 23.17 ± 2.04, height: 174.17 ± 6.46 cm) participated in a controlled environment data collection and performed a series of gait tasks with both systems attached to each ankle. A total of 2820 strides were analyzed. The results show a median absolute stride length error of 1.86 cm between the IMU-based wearable device reconstruction and the motion capture ground truth, with the 75th percentile at 3.24 cm. The median absolute stride horizontal velocity error was 1.56 cm/s, with the 75th percentile at 2.63 cm/s. With a measurement error to the reference system of less than 3 cm, we conclude that there is a valid physical recovery of stride length and horizontal velocity from data collected with the IMU-based wearable Syde® device.


Asunto(s)
Tobillo , Marcha , Dispositivos Electrónicos Vestibles , Humanos , Marcha/fisiología , Masculino , Tobillo/fisiología , Femenino , Adulto , Adulto Joven , Fenómenos Biomecánicos/fisiología , Acelerometría/instrumentación , Acelerometría/métodos , Análisis de la Marcha/métodos , Análisis de la Marcha/instrumentación
6.
Sensors (Basel) ; 24(8)2024 Apr 14.
Artículo en Inglés | MEDLINE | ID: mdl-38676136

RESUMEN

The accurate estimation of energy expenditure from simple objective accelerometry measurements provides a valuable method for investigating the effect of physical activity (PA) interventions or population surveillance. Methods have been evaluated previously, but none utilize the temporal aspects of the accelerometry data. In this study, we investigated the energy expenditure prediction from acceleration measured at the subjects' hip, wrist, thigh, and back using recurrent neural networks utilizing temporal elements of the data. The acceleration was measured in children (N = 33) performing a standardized activity protocol in their natural environment. The energy expenditure was modelled using Multiple Linear Regression (MLR), stacked long short-term memory (LSTM) networks, and combined convolutional neural networks (CNN) and LSTM. The correlation and mean absolute percentage error (MAPE) were 0.76 and 19.9% for the MLR, 0.882 and 0.879 and 14.22% for the LSTM, and, with the combined LSTM-CNN, the best performance of 0.883 and 13.9% was achieved. The prediction error for vigorous intensities was significantly different (p < 0.01) from those of the other intensity domains: sedentary, light, and moderate. Utilizing the temporal elements of movement significantly improves energy expenditure prediction accuracy compared to other conventional approaches, but the prediction error for vigorous intensities requires further investigation.


Asunto(s)
Acelerometría , Metabolismo Energético , Redes Neurales de la Computación , Humanos , Acelerometría/métodos , Metabolismo Energético/fisiología , Masculino , Femenino , Niño , Ejercicio Físico/fisiología , Modelos Lineales , Memoria a Corto Plazo/fisiología
7.
Int J Behav Nutr Phys Act ; 21(1): 43, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38654342

RESUMEN

BACKGROUND: The development of validated "fit-for-purpose" rapid assessment tools to measure 24-hour movement behaviours in children aged 0-5 years is a research priority. This study evaluated the test-retest reliability and concurrent validity of the open-ended and closed-ended versions of the Movement Behaviour Questionnaire for baby (MBQ-B) and child (MBQ-C). METHODS: 300 parent-child dyads completed the 10-day study protocol (MBQ-B: N = 85; MBQ-C: N = 215). To assess validity, children wore an accelerometer on the non-dominant wrist (ActiGraph GT3X+) for 7 days and parents completed 2 × 24-hour time use diaries (TUDs) recording screen time and sleep on two separate days. For babies (i.e., not yet walking), parents completed 2 × 24-hour TUDs recording tummy time, active play, restrained time, screen time, and sleep on days 2 and 5 of the 7-day monitoring period. To assess test-retest reliability, parents were randomised to complete either the open- or closed-ended versions of the MBQ on day 7 and on day 10. Test-retest intraclass correlation coefficients (ICC's) were calculated using generalized linear mixed models and validity was assessed via Spearman correlations. RESULTS: Test-retest reliability for the MBQ-B was good to excellent with ICC's ranging from 0.80 to 0.94 and 0.71-0.93 for the open- and closed-ended versions, respectively. For both versions, significant positive correlations were observed between 24-hour diary and MBQ-B reported tummy time, active play, restrained time, screen time, and sleep (rho = 0.39-0.87). Test-retest reliability for the MBQ-C was moderate to excellent with ICC's ranging from 0.68 to 0.98 and 0.44-0.97 for the open- and closed-ended versions, respectively. For both the open- and closed-ended versions, significant positive correlations were observed between 24-hour diary and MBQ-C reported screen time and sleep (rho = 0.44-0.86); and between MBQ-C reported and device-measured time in total activity and energetic play (rho = 0.27-0.42). CONCLUSIONS: The MBQ-B and MBQ-C are valid and reliable rapid assessment tools for assessing 24-hour movement behaviours in infants, toddlers, and pre-schoolers. Both the open- and closed-ended versions of the MBQ are suitable for research conducted for policy and practice purposes, including the evaluation of scaled-up early obesity prevention programs.


Asunto(s)
Padres , Sueño , Humanos , Lactante , Femenino , Masculino , Reproducibilidad de los Resultados , Preescolar , Encuestas y Cuestionarios/normas , Sueño/fisiología , Acelerometría/métodos , Acelerometría/instrumentación , Conducta Infantil , Tiempo de Pantalla , Movimiento , Recién Nacido , Conducta Sedentaria , Ejercicio Físico
8.
Int J Behav Nutr Phys Act ; 21(1): 48, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671485

RESUMEN

BACKGROUND: Sedentary behavior (SB) is a recognized risk factor for many chronic diseases. ActiGraph and activPAL are two commonly used wearable accelerometers in SB research. The former measures body movement and the latter measures body posture. The goal of the current study is to quantify the pattern and variation of movement (by ActiGraph activity counts) during activPAL-identified sitting events, and examine associations between patterns and health-related outcomes, such as systolic and diastolic blood pressure (SBP and DBP). METHODS: The current study included 314 overweight postmenopausal women, who were instructed to wear an activPAL (at thigh) and ActiGraph (at waist) simultaneously for 24 hours a day for a week under free-living conditions. ActiGraph and activPAL data were processed to obtain minute-level time-series outputs. Multilevel functional principal component analysis (MFPCA) was applied to minute-level ActiGraph activity counts within activPAL-identified sitting bouts to investigate variation in movement while sitting across subjects and days. The multilevel approach accounted for the nesting of days within subjects. RESULTS: At least 90% of the overall variation of activity counts was explained by two subject-level principal components (PC) and six day-level PCs, hence dramatically reducing the dimensions from the original minute-level scale. The first subject-level PC captured patterns of fluctuation in movement during sitting, whereas the second subject-level PC delineated variation in movement during different lengths of sitting bouts: shorter (< 30 minutes), medium (30 -39 minutes) or longer (> 39 minute). The first subject-level PC scores showed positive association with DBP (standardized ß ^ : 2.041, standard error: 0.607, adjusted p = 0.007), which implied that lower activity counts (during sitting) were associated with higher DBP. CONCLUSION: In this work we implemented MFPCA to identify variation in movement patterns during sitting bouts, and showed that these patterns were associated with cardiovascular health. Unlike existing methods, MFPCA does not require pre-specified cut-points to define activity intensity, and thus offers a novel powerful statistical tool to elucidate variation in SB patterns and health. TRIAL REGISTRATION: ClinicalTrials.gov NCT03473145; Registered 22 March 2018; https://clinicaltrials.gov/ct2/show/NCT03473145 ; International Registered Report Identifier (IRRID): DERR1-10.2196/28684.


Asunto(s)
Análisis de Componente Principal , Conducta Sedentaria , Sedestación , Dispositivos Electrónicos Vestibles , Humanos , Femenino , Persona de Mediana Edad , Acelerometría/instrumentación , Acelerometría/métodos , Presión Sanguínea/fisiología , Actigrafía/instrumentación , Actigrafía/métodos , Anciano , Sobrepeso , Posmenopausia/fisiología , Ejercicio Físico/fisiología , Movimiento
9.
Front Public Health ; 12: 1288262, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38560447

RESUMEN

The 24-h movement behavior of preschoolers comprises a spectrum of activities, including moderate-to-vigorous intensity physical activity (MVPA), light-intensity physical activity (LPA), screen-based sedentary behavior (SCSB), non-screen-based sedentary behavior (NSCSB), and sleep. While previous research has shed light on the link between movement behaviors and children's mental health, the specific impacts on the unique demographic of Chinese preschoolers remain underexplored. This study significantly contributes to the literature by exploring how 24-h movement behavior affects the mental health of preschoolers in a Chinese context. The study involved205 Chinese preschool children (117 boys and 88 girls) between the ages of 3 and 6 years wore accelerometers to measure their LPA, MVPA, and sedentary behavior (SB), while their parents reported the time spent on sleep and SCSB. The parents also completed the Strength and Difficulties Questionnaire to assess their children's mental health. The study used compositional regression and isotemporal substitution models to examine the relationship between the various components of 24-h movement behavior and mental health. The results showed that greater NCSSB compared to MVPA, LPA, sleep, and SCSB was associated with good prosocial behavior and lower scores on externalizing problems. This highlights the potential of NSCSB as a beneficial component in the daily routine of preschoolers for fostering mental well-being. Replacing 15 min of sleep and SCSB with 15 min of NSCSB was associated with a decrease of 0.24 and 0.15 units, respectively, in externalizing problems. Reallocating 15 min of sleep to NSCSB was linked to an increase of 0.11 units in prosocial behavior. There were no significant substitution effects between LPA and MVPA time with any other movement behavior on prosocial behavior and externalizing problems. Given the positive associations observed, further longitudinal studies are necessary to explore the link between 24-h movement behavior and mental health in preschool children.


Asunto(s)
Acelerometría , Salud Mental , Masculino , Femenino , Humanos , Preescolar , Niño , Acelerometría/métodos , Ejercicio Físico , Conducta Sedentaria , Factores de Tiempo
10.
Sao Paulo Med J ; 142(4): e2023144, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38511771

RESUMEN

BACKGROUND: Compared to young individuals, older adults participate more in sedentary behavior (SB) and less in physical activity (PA). These behaviors are associated with numerous adverse health factors. OBJECTIVE: The purpose of the study was to examine the hypothetical effects of substituting time spent sleeping, performing SB, and performing moderate-to-vigorous physical activity (MVPA) on depressive symptomatology in older adults. DESIGN AND SETTING: An analytical cross-sectional study employing exploratory survey methods was conducted in the city of Alcobaça in the state of Bahia, Brazil. METHODS: The study included 473 older adults who answered a structured questionnaire during an interview. Exposure time to SB and PA level were assessed using the International Physical Activity Questionnaire, and depressive symptoms were analyzed using the short version of the Geriatric Depression Scale. An isotemporal replacement model was used to evaluate the effects of different SB sessions on depressive symptomatology. RESULTS: An increase in the risk of depressive symptoms was observed when MVPA and sleep time were substituted for the same SB time at all times tested, with maximum values of 40% and 20%, respectively. Opposite substitution of MVPA and sleep time increments reduced the risk of depressive symptomatology by 28% and 17%, respectively. CONCLUSIONS: The results of the present study indicate that replacing SB with the same amount of sleep or MVPA may reduce depressive symptoms. The longer the reallocation time, the greater are the benefits.


Asunto(s)
Depresión , Conducta Sedentaria , Humanos , Anciano , Estudios Transversales , Depresión/diagnóstico , Acelerometría/métodos , Ejercicio Físico , Sueño
11.
PeerJ ; 12: e16990, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38468640

RESUMEN

Background: Physical activity (PA) is associated with numerous health benefits. Vigorous PA (VPA) may have a greater impact on public health than lower-intensity PA. The incorporation of a specific recommendation on VPA could complement and improve existing recommendations for average daily moderate-vigorous PA (MVPA). Physical education classes could have a positive impact on children's adherence to average daily physical activity recommendations. The aim was to investigate the association between MVPA and VPA in children, as well as adherence to recommendations, and obesity and the presence of physical education classes. Methods: A cross-sectional study of physical activity was conducted in a sample of 8 and 9-year-old children in Andalusia (Spain). GENEActiv accelerometers were used, placed on the non-dominant wrist for at least eight consecutive days (24-h protocol). School days with and without physical education class, and weekend days were defined. ROC curves were used to calculate the threshold associated with obesity for average daily MVPA and VPA for recommendations. Results: A total of 360 schoolchildren were included in the analyses (184 girls). An average of 7.7 (SD 1.4) valid days per participant were evaluated, with 19.9 (SD 10.5) and 11.4 (SD 5.1) minutes of VPA performed by boys and girls respectively. 25.8% of the participants were classified with central obesity. The optimal threshold determined with ROC analysis was 12.5 and 9.5 minutes of average daily VPA for boys and girls, respectively (RecVPA), and 75 minutes of average daily MVPA for both sexes (RecMVPA). The RecVPA showed stronger association with obesity. On school days with physical education class, compared to days without this class, children showed increased VPA and MVPA engagement and better compliance with recommendations, with smaller differences in adherence according to sex or obesity. Conclusions: On days with physical education class, more physical activity was accumulated at all intensities and greater adherence to the recommendations than on days without this class. VPA had a stronger correlation with the absence of obesity than lower-intensity activity. It was also observed that boys were physically more active and had higher adherence to the recommendations than girls.


Asunto(s)
Actividad Motora , Educación y Entrenamiento Físico , Masculino , Niño , Femenino , Humanos , Estudios Transversales , Ejercicio Físico , Obesidad , Acelerometría/métodos
12.
J Sports Sci ; 42(1): 9-16, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38394032

RESUMEN

The influence of the ActiGraph® processing criteria on estimating step counts in chronic obstructive pulmonary disease (COPD) remains uncertain. This study aimed to assess the influence of filters, epoch lengths and non-wearing time (NWT) algorithms on steps/day in people with COPD. ActiGraph GT3X+ was worn on the waist for seven days. Steps were detected using different filters (normal and low-frequency extension [LFE]), epoch lengths (15s and 60s), and NWT algorithms (Choi and Troiano). Linear mixed-effects model was applied to assess the effects of filter, epoch length, NWT algorithm on steps/day. Lin's concordance correlation and Bland-Altman were used to measure agreement. A total of 136 people with COPD (107 male; 69 ± 8 years; FEV1 51 ± 17% predicted) were included. Significant differences were found between filters (p < 0.001), but not between epoch lengths or NWT algorithms. The LFE increased, on average, approximately 7500 steps/day compared to the normal filter (p < 0.001). Agreement was poor (<0.3) and proportional bias was significant when comparing steps/day computed with different filters, regardless of the epoch length and NWT algorithm. Filter choice but not epoch lengths or NWT algorithms seem to impact measurement of steps/day. Future studies are needed to recommend the most accurate technique for measuring steps/day in people with COPD.


Asunto(s)
Actigrafía , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Masculino , Actigrafía/métodos , Acelerometría/métodos , Tiempo , Algoritmos
13.
J Neuroeng Rehabil ; 21(1): 31, 2024 02 29.
Artículo en Inglés | MEDLINE | ID: mdl-38419099

RESUMEN

BACKGROUND: Children and adolescents with neuromotor disorders need regular physical activity to maintain optimal health and functional independence throughout their development. To this end, reliable measures of physical activity are integral to both assessing habitual physical activity and testing the efficacy of the many interventions designed to increase physical activity in these children. Wearable accelerometers have been used for children with neuromotor disorders for decades; however, studies most often use disorder-specific cut points to categorize physical activity intensity, which lack generalizability to a free-living environment. No reviews of accelerometer data processing methods have discussed the novel use of machine learning techniques for monitoring physical activity in children with neuromotor disorders. METHODS: In this narrative review, we discuss traditional measures of physical activity (including questionnaires and objective accelerometry measures), the limitations of standard analysis for accelerometry in this unique population, and the potential benefits of applying machine learning approaches. We also provide recommendations for using machine learning approaches to monitor physical activity. CONCLUSIONS: While wearable accelerometers provided a much-needed method to quantify physical activity, standard cut point analyses have limitations in children with neuromotor disorders. Machine learning models are a more robust method of analyzing accelerometer data in pediatric neuromotor disorders and using these methods over disorder-specific cut points is likely to improve accuracy of classifying both type and intensity of physical activity. Notably, there remains a critical need for further development of classifiers for children with more severe motor impairments, preschool aged children, and children in hospital settings.


Asunto(s)
Acelerometría , Ejercicio Físico , Niño , Preescolar , Humanos , Adolescente , Acelerometría/métodos , Aprendizaje Automático
14.
Sci Rep ; 14(1): 3039, 2024 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-38321039

RESUMEN

Real-world walking data offers rich insights into a person's mobility. Yet, daily life variations can alter these patterns, making the data challenging to interpret. As such, it is essential to integrate context for the extraction of meaningful information from real-world movement data. In this work, we leveraged the relationship between the characteristics of a walking bout and context to build a classification algorithm to distinguish between indoor and outdoor walks. We used data from 20 participants wearing an accelerometer on the thigh over a week. Their walking bouts were isolated and labeled using GPS and self-reporting data. We trained and validated two machine learning models, random forest and ensemble Support Vector Machine, using a leave-one-participant-out validation scheme on 15 subjects. The 5 remaining subjects were used as a testing set to choose a final model. The chosen model achieved an accuracy of 0.941, an F1-score of 0.963, and an AUROC of 0.931. This validated model was then used to label the walks from a different dataset with 15 participants wearing the same accelerometer. Finally, we characterized the differences between indoor and outdoor walks using the ensemble of the data. We found that participants walked significantly faster, longer, and more continuously when walking outdoors compared to indoors. These results demonstrate how movement data alone can be used to obtain accurate information on important contextual factors. These factors can then be leveraged to enhance our understanding and interpretation of real-world movement data, providing deeper insights into a person's health.


Asunto(s)
Aprendizaje Automático , Caminata , Humanos , Algoritmos , Acelerometría/métodos , Proyectos de Investigación
15.
Sensors (Basel) ; 24(4)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38400258

RESUMEN

Various accelerometry protocols have been used to quantify upper extremity (UE) activity, encompassing diverse epoch lengths and thresholding methods. However, there is no consensus on the most effective approach. The aim of this study was to delineate the optimal parameters for analyzing accelerometry data to quantify UE use in individuals with unilateral cerebral palsy (CP). METHODS: A group of adults with CP (n = 15) participated in six activities of daily living, while a group of children with CP (n = 14) underwent the Assisting Hand Assessment. Both groups performed the activities while wearing ActiGraph GT9X-BT devices on each wrist, with concurrent video recording. Use ratio (UR) derived from accelerometry and video analysis and accelerometer data were compared for different epoch lengths (1, 1.5, and 2 s) and activity count (AC) thresholds (between 2 and 150). RESULTS: In adults, results are comparable across epoch lengths, with the best AC thresholds being ≥ 100. In children, results are similar across epoch lengths of 1 and 1.5 (optimal AC threshold = 50), while the optimal threshold is higher with an epoch length of 2 (AC = 75). CONCLUSIONS: The combination of epoch length and AC thresholds should be chosen carefully as both influence the validity of the quantification of UE use.


Asunto(s)
Parálisis Cerebral , Niño , Adulto , Humanos , Actividades Cotidianas , Extremidad Superior , Acelerometría/métodos , Muñeca
16.
Sensors (Basel) ; 24(4)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38400313

RESUMEN

Estimation of temporospatial clinical features of gait (CFs), such as step count and length, step duration, step frequency, gait speed, and distance traveled, is an important component of community-based mobility evaluation using wearable accelerometers. However, accurate unsupervised computerized measurement of CFs of individuals with Duchenne muscular dystrophy (DMD) who have progressive loss of ambulatory mobility is difficult due to differences in patterns and magnitudes of acceleration across their range of attainable gait velocities. This paper proposes a novel calibration method. It aims to detect steps, estimate stride lengths, and determine travel distance. The approach involves a combination of clinical observation, machine-learning-based step detection, and regression-based stride length prediction. The method demonstrates high accuracy in children with DMD and typically developing controls (TDs) regardless of the participant's level of ability. Fifteen children with DMD and fifteen TDs underwent supervised clinical testing across a range of gait speeds using 10 m or 25 m run/walk (10 MRW, 25 MRW), 100 m run/walk (100 MRW), 6-min walk (6 MWT), and free-walk (FW) evaluations while wearing a mobile-phone-based accelerometer at the waist near the body's center of mass. Following calibration by a trained clinical evaluator, CFs were extracted from the accelerometer data using a multi-step machine-learning-based process and the results were compared to ground-truth observation data. Model predictions vs. observed values for step counts, distance traveled, and step length showed a strong correlation (Pearson's r = -0.9929 to 0.9986, p < 0.0001). The estimates demonstrated a mean (SD) percentage error of 1.49% (7.04%) for step counts, 1.18% (9.91%) for distance traveled, and 0.37% (7.52%) for step length compared to ground-truth observations for the combined 6 MWT, 100 MRW, and FW tasks. Our study findings indicate that a single waist-worn accelerometer calibrated to an individual's stride characteristics using our methods accurately measures CFs and estimates travel distances across a common range of gait speeds in both DMD and TD peers.


Asunto(s)
Teléfono Celular , Caminata , Niño , Humanos , Velocidad al Caminar , Aprendizaje Automático , Acelerometría/métodos , Marcha
17.
JAMA Cardiol ; 9(4): 336-345, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38381446

RESUMEN

Importance: Heart failure (HF) prevention is paramount to public health in the 21st century. Objective: To examine incident HF and its subtypes with preserved ejection fraction (HFpEF) and reduced EF (HFrEF) according to accelerometer-measured physical activity (PA) and sedentary time. Design, Setting, and Participants: This was a prospective cohort study, the Objective Physical Activity and Cardiovascular Health (OPACH) in Older Women study, conducted from March 2012 to April 2014. Included in the analysis were women aged 63 to 99 years without known HF, who completed hip-worn triaxial accelerometry for 7 consecutive days. Follow-up for incident HF occurred through February 2022. Data were analyzed from March to December 2023. Exposure: Daily PA (total, light, moderate to vigorous PA [MVPA], steps) and sedentary (total, mean bout duration) behavior. Main Outcomes and Measures: Adjudicated incident HF, HFpEF, and HFrEF. Results: A total of 5951 women (mean [SD] age, 78.6 [6.8] years) without known HF were included in this analysis. Women self-identified with the following race and ethnicity categories: 2004 non-Hispanic Black (33.7%), 1022 Hispanic (17.2%), and 2925 non-Hispanic White (49.2%). There were 407 HF cases (257 HFpEF; 110 HFrEF) identified through a mean (SD) of 7.5 (2.6) years (range, 0.01-9.9 years) of follow-up. Fully adjusted hazard ratios (HRs) for overall HF, HFpEF, and HFrEF associated with a 1-SD increment were 0.85 (95% CI, 0.75-0.95), 0.78 (95% CI, 0.67-0.91), and 1.02 (95% CI, 0.81-1.28) for minutes per day total PA; 0.74 (95% CI, 0.63-0.88), 0.71 (95% CI, 0.57-0.88), and 0.83 (95% CI, 0.62-1.12) for steps per day; and 1.17 (95% CI, 1.04-1.33), 1.29 (95% CI, 1.10-1.51), and 0.94 (95% CI, 0.75-1.18) for minutes per day total sedentary. Cubic spline curves for overall HF and HFpEF were significant inverse for total PA and steps per day and positive for total sedentary. Light PA and MVPA were inversely associated with overall HF (HR per 1 SD: 0.88; 95% CI, 0.78-0.98 and 0.84; 95% CI, 0.73-0.97) and HFpEF (0.80; 95% CI, 0.70-0.93 and 0.85; 95% CI, 0.72-1.01) but not HFrEF. Associations did not meaningfully differ when stratified by age, race and ethnicity, body mass index, physical function, or comorbidity score. Results for sedentary bout duration were inconsistent. Conclusions and Relevance: Higher accelerometer-measured PA (MVPA, light PA, steps per day) was associated with lower risk (and greater total sedentary time with higher risk) of overall HF and HFpEF in a racially and ethnically diverse cohort of older women. Increasing PA and reducing sedentary time for primary HFpEF prevention may have relevant implications for cardiovascular resilience and healthy aging in later life.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Femenino , Anciano , Masculino , Estudios Prospectivos , Volumen Sistólico , Conducta Sedentaria , Ejercicio Físico , Acelerometría/métodos
18.
Biomed Eng Online ; 23(1): 21, 2024 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-38368358

RESUMEN

BACKGROUND: Human activity Recognition (HAR) using smartphone sensors suffers from two major problems: sensor orientation and placement. Sensor orientation and sensor placement problems refer to the variation in sensor signal for a particular activity due to sensors' altering orientation and placement. Extracting orientation and position invariant features from raw sensor signals is a simple solution for tackling these problems. Using few heuristic features rather than numerous time-domain and frequency-domain features offers more simplicity in this approach. The heuristic features are features which have very minimal effects of sensor orientation and placement. In this study, we evaluated the effectiveness of four simple heuristic features in solving the sensor orientation and placement problems using a 1D-CNN-LSTM model for a data set consisting of over 12 million samples. METHODS: We accumulated data from 42 participants for six common daily activities: Lying, Sitting, Walking, and Running at 3-Metabolic Equivalent of Tasks (METs), 5-METs and 7-METs from a single accelerometer sensor of a smartphone. We conducted our study for three smartphone positions: Pocket, Backpack and Hand. We extracted simple heuristic features from the accelerometer data and used them to train and test a 1D-CNN-LSTM model to evaluate their effectiveness in solving sensor orientation and placement problems. RESULTS: We performed intra-position and inter-position evaluations. In intra-position evaluation, we trained and tested the model using data from the same smartphone position, whereas, in inter-position evaluation, the training and test data was from different smartphone positions. For intra-position evaluation, we acquired 70-73% accuracy; for inter-position cases, the accuracies ranged between 59 and 69%. Moreover, we performed participant-specific and activity-specific analyses. CONCLUSIONS: We found that the simple heuristic features are considerably effective in solving orientation problems. With further development, such as fusing the heuristic features with other methods that eliminate placement issues, we can also achieve a better result than the outcome we achieved using the heuristic features for the sensor placement problem. In addition, we found the heuristic features to be more effective in recognizing high-intensity activities.


Asunto(s)
Heurística , Teléfono Inteligente , Humanos , Actividades Humanas , Caminata , Acelerometría/métodos
19.
Sensors (Basel) ; 24(3)2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38339597

RESUMEN

BACKGROUND: Self-reported adherence to sling wear is unreliable due to recall bias. We aim to assess the feasibility and accuracy of quantifying sling wear and non-wear utilising slings pre-fitted with a GENEActiv accelerometer that houses triaxial acceleration and temperature sensors. METHODS: Ten participants were asked to wear slings for 480 min (8 h) incorporating 180 min of non-wear time in durations varying from 5-120 min. GENEActiv devices were fitted in sutured inner sling pockets and participants logged sling donning and doffing times. An algorithm based on variability in acceleration in three axes and temperature change was developed to identify sling wear and non-wear and compared to participants' logs. RESULTS: There was no significant difference between algorithm detected non-wear duration (mean ± standard deviation = 172.0 ± 6.8 min/participant) and actual non-wear (179.7 ± 1.0 min/participant). Minute-by-minute agreement of sensor-detected wear and non-wear with participant reported wear was 97.3 ± 1.5% (range = 93.9-99.0), with mean sensitivity 94.3 ± 3.5% (range = 86.1-98.3) and specificity 99.1 ± 0.8% (range = 93.7-100). CONCLUSION: An algorithm based on accelerometer-assessed acceleration and temperature can accurately identify shoulder sling wear/non-wear times. This method may have potential for assessing whether sling wear adherence after shoulder surgeries have any bearing on patient functional outcomes.


Asunto(s)
Acelerometría , Hombro , Humanos , Temperatura , Estudios de Factibilidad , Acelerometría/métodos , Aceleración
20.
Sensors (Basel) ; 24(3)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38339613

RESUMEN

Sedentary behaviour (SB) and physical activity (PA) have been shown to be independent modulators of healthy ageing. We thus investigated the impact of activity monitor placement on the accuracy of detecting SB and PA in older adults, as well as a novel random forest algorithm trained on data from older persons. Four monitor types (ActiGraph wGT3X-BT, ActivPAL3c VT, GENEActiv Original, and DynaPort MM+) were simultaneously worn on five anatomical sites during ten different activities by a sample of twenty older adults (70.0 (12.0) years; 10 women). The results indicated that collecting metabolic equivalent (MET) data for 60 s provided the most representative results, minimising variability. In addition, thigh-worn monitors, including ActivPAL, Random Forest, and Sedentary Sphere-Thigh, exhibited superior performance in classifying SB, with balanced accuracies ≥ 94.2%. Other monitors, such as ActiGraph, DynaPort MM+, and GENEActiv Sedentary Sphere-Wrist, demonstrated lower performance. ActivPAL and GENEActiv Random Forest outperformed other monitors in participant-specific balanced accuracies for SB classification. Only thigh-worn monitors achieved acceptable overall balanced accuracies (≥80.0%) for SB, standing, and medium-to-vigorous PA classifications. In conclusion, it is advisable to position accelerometers on the thigh, collect MET data for ≥60 s, and ideally utilise population-specific trained algorithms.


Asunto(s)
Acelerometría , Ejercicio Físico , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Acelerometría/métodos , Muslo , Muñeca , Algoritmos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...