RESUMEN
PURPOSE: This study describes a prototype developed for aphakia without capsular support (AWCS) and its proof of concept. METHODS: This descriptive study used a 3D software to create and analyze virtual prototypes before manufacturing. A nylon-6/nylon-6.6 copolymer filament and a 3D printer were used for prototyping. A device implantation technique was developed using a 23-gauge hypodermic needle. Two opposing markings, 2 mm posterior to the limbus, were made to determine the location of the scleral punctures and the final position of the device. After adequate centralization and positioning of the device, its haptics were cut and cauterized to generate thermal modeling of the extremity and allow the thickening of the tips (flange), serving as an anchoring mechanism to the sclera. The efficacy and adequacy of the technique and device were then evaluated. RESULTS: Vitreous tissue extrusion was not observed during the sclerotomy. The device was well fixed to the sclera; however, adequate IOL stability and centralization still needed to be achieved. The surgeon evaluated the adequacy of all the other devices' characteristics. CONCLUSIONS: The development of a technology prototype for correcting AWCS was possible. Although the proposed prototype met most of the established concept guidelines, the stability of the IOL position remains challenging.
Asunto(s)
Afaquia Poscatarata , Humanos , Afaquia Poscatarata/cirugía , Afaquia Poscatarata/fisiopatología , Cápsula del Cristalino/cirugía , Lentes Intraoculares , Esclerostomía , Implantación de Lentes Intraoculares/métodos , Esclerótica/cirugía , Afaquia/cirugía , Impresión Tridimensional , Diseño de Prótesis , Agudeza Visual/fisiologíaRESUMEN
Objetivo: Caracterizar resultados visuales del implante de lente intraocular plegable de cámara posterior suturada al iris en la afaquia traumática de pacientes pediátricos. Métodos: Se realizó un estudio preexperimental, prospectivo, longitudinal con 17 niños, con seguimiento de un año. Se les realizó examen oftalmológico completo y se evaluaron variables como edad, sexo, lateralidad, mejor agudeza visual sin corrección, con corrección, resultados refractivos, presión intraocular, y complicaciones. Resultados: La edad promedio fue de 13,2 años, masculinos fueron el 64,7 por ciento. La mejor agudeza visual sin corrección en el preoperatorio fue del 47,1 por ciento <0,1 y con corrección de 0,7, al año del posoperatorio fue de 0,43/0,78, respectivamente. La presión intraocular preoperatoria fue de 14,1 mm Hg, y al año 14,71 mm Hg. La densidad celular en el preoperatorio fue de 2559.76 células/mm2 y al año de 2475,88 células/mm2. La hexagonalidad preoperatorio fue del 53,12 por ciento y al año del 56,94 por ciento. El cilindro preoperatorio -1,35 D y el 23,5 por ciento presentó astigmatismo inducido al año del posoperatorio. Conclusiones: La aplicación del implante de lente intraocular plegable de cámara posterior suturada al iris en la afaquia traumática de pacientes pediátricos logra mejorar su agudeza visual y la complicación más frecuente fue el edema corneal(AU)
Objective: To characterize visual outcomes of iris-sutured posterior chamber foldable intraocular lens implantation in traumatic aphakia in pediatric patients. Methods: A pre-experimental, prospective, longitudinal, pre-experimental study was performed with 17 children, with a one-year follow-up. A complete ophthalmologic examination was performed and variables such as age, sex, laterality, best visual acuity without correction, with correction, refractive results, intraocular pressure and complications were evaluated. Results: The average age was 13.2 years, 64.7 percent were male. The best visual acuity without correction preoperatively was 47.1 percent <0.1 and with correction 0.7, one year postoperative visual acuity was 0.43/0.78, respectively. Preoperative intraocular pressure was 14.1 mm Hg, and at one year 14.71 mm Hg. Cell density preoperatively was 2559.76 cells/mm2 and at one year 2475.88 cells/mm2. The preoperative hexagonality was 53.12 percent and at one year 56.94 percent. Preoperative cylinder -1.35 D and 23.5 percent presented induced astigmatism at one year postoperatively. Conclusions: The application of posterior chamber foldable intraocular lens implant sutured to the iris in traumatic aphakia in pediatric patients achieves improved visual acuity and the most frequent complication was corneal edema(AU)
Asunto(s)
Humanos , Masculino , Niño , Afaquia , Edema Corneal/complicaciones , Estudios Prospectivos , Estudios LongitudinalesRESUMEN
Objetivo: Caracterizar los resultados refractivos del implante de una lente intraocular plegable de cámara posterior suturada al iris en la afaquia sin o con inadecuado soporte capsular. Métodos: Se realizó un estudio descriptivo, prospectivo y longitudinal, en el que se incluyeron 30 pacientes (30 ojos) seguidos por un período de un año de septiembre de 2019 a septiembre de 2021, después del implante de una lente intraocular de cámara posterior suturada al iris en la afaquia. Se les realizó examen oftalmológico completo y se evaluaron variables como mejor agudeza visual sin corrección, con corrección, resultados refractivos, presión intraocular, astigmatismo inducido, densidad celular y complicaciones. Resultados: La mejor agudeza visual sin corrección en el preoperatorio fue del 93,3 por ciento (<0,1) y con corrección de 0,66, al año del posoperatorio fue de 0,493/0,890, respectivamente. La presión intraocular preoperatoria fue de 20,7 mmHg, y al año 19,7 mmHg. La densidad celular en el preoperatorio fue de 1755,7 cél/mm2 y al año fue de 1363,8 cél/mm2, y en los pacientes bien corregidos al mes del posoperatorio fue de 73,4 por ciento y al año de 70 por ciento. El astigmatismo inducido en el posoperatorio al año fue de -0,51 D. Conclusiones: La agudeza visual sin corrección y con corrección mejoran después del implante de una lente intraocular plegable de cámara posterior suturada al iris en la afaquia sin o con inadecuado soporte capsular. Predominan los pacientes bien corregidos, sin cambios en la presión intraocular y la complicación más frecuente fue el edema corneal(AU)
Objective: To characterize the refractive outcomes of implanting a posterior chamber foldable intraocular lens sutured to the iris in aphakia without or with inadequate capsular support. Methods: A descriptive, prospective and longitudinal study was carried out, including 30 patients (30 eyes) followed up for a period of one year, from September 2019 to September 2021, after being implanted a posterior chamber intraocular lens sutured to the iris in aphakia. Complete ophthalmologic examination was performed and variables were assessed, such as best visual acuity without correction, with correction, refractive results, intraocular pressure, induced astigmatism, cell density and complications. Results: The best visual acuity without correction in the preoperative period was 93.3 % (<0.1) and 0.66 with correction; while one-year postoperative visual acuity was 0.493 and 0.890, respectively. Preoperative intraocular pressure was 20.7 mmHg, while it was 19.7 mmHg at one year. Preoperatively cell density was 1755.7 cells/mm2, and it was 1363.8 cells/mm2 at one year it; while in well-corrected patients, it was 73.4 percent at one month postoperatively and 70 percent at one year. Postoperative induced astigmatism at one year was -0.51 D. Conclusions: Both uncorrected and corrected visual acuity improve after implantation of a posterior chamber foldable intraocular lens sutured to the iris in aphakia without or with inadequate capsular support. Well-corrected patients predominate, with no change in intraocular pressure, while the most frequent complication was corneal edema(AU)
Asunto(s)
Humanos , Afaquia , Epidemiología Descriptiva , Estudios ProspectivosRESUMEN
PURPOSE: The aim of this study was to define risks for corneal transplantation associated with fibrous ingrowth among first-time transplant recipients. METHODS: We performed a retrospective case-control study of patients with a histopathologic diagnosis of fibrous ingrowth between 2002 and 2019. Patients with fibrous ingrowth from a first corneal specimen were included. Those with incomplete records were excluded. A 1:2 case-control ratio was used. Controls were matched using surgical indication, surgery year, transplantation method, sex, and age. RESULTS: Seventy-eight eyes (76 patients) were included and matched with 160 control eyes. The incidence of fibrous ingrowth found on a first corneal transplant was 0.6% per year. The most common keratoplasty indications were pseudophakic corneal edema (n = 25, 32%) and aphakic corneal edema (n = 15, 19%). Cases were more likely to have a history of ocular trauma (odds ratio [OR], 2.94; 95% CI, 1.30-6.30; P = 0.007), uveitis (OR, 2.73; 95% CI, 1.12-6.63; P = 0.022), retinal detachment or previous retinal surgery (OR, 2.40; 95% CI, 1.34-4.30; P = 0.003), glaucoma tube-shunt surgery (OR, 2.70; 95% CI, 1.29-5.65; P = 0.007), aphakia (OR, 3.02; 95% CI, 1.61-5.67; P = 0.0004), or iris derangement (OR, 10.52; 95% CI, 5.45-20.30; P <0.0001). A multivariate logistic regression model using iris derangement, history of ocular trauma, history of uveitis, and history of cataract surgery demonstrated 81% sensitivity and 66% specificity in predicting presence of fibrous ingrowth. CONCLUSIONS: A history of ocular trauma, uveitis, retinal detachment or previous retinal surgery, glaucoma tube-shunt surgery, aphakia, and iris derangement are risks for detecting fibrous ingrowth among first-time keratoplasty recipients. Patients with these conditions should be monitored closely for corneal decompensation.
Asunto(s)
Afaquia , Edema Corneal , Trasplante de Córnea , Lesiones Oculares , Glaucoma , Desprendimiento de Retina , Uveítis , Humanos , Edema Corneal/cirugía , Estudios Retrospectivos , Desprendimiento de Retina/cirugía , Estudios de Casos y Controles , Trasplante de Córnea/efectos adversos , Lesiones Oculares/complicaciones , Factores de Riesgo , Glaucoma/cirugía , Afaquia/cirugía , Uveítis/complicacionesRESUMEN
PURPOSE: To evaluate primary intraocular lens implantation in the treatment of children's aphakia in the Brazilian public health system and compare the outcomes among different age groups. METHODS: Children aged 0-12 years old with unilateral or bilateral congenital/developmental cataracts and underwent primary intraocular lens implantation were included. RESULTS: A total of 108 eyes from 68 children were evaluated, and the children were divided into four age groups (<7 months [mo]; 7 mo-2 years old [y/o]; 2-5 y/o, and >5 y/o) were evaluated. Nineteen eyes (17.59%) presented visual axis opacification as a postoperative complication, which was more frequently observed in the <7 mo age group (37.93%). The difference was significant between the <7 mo and >5 y/o age groups (p=0.002). Visual axis opacification was divided into two categories: pupillary membrane and lens cell proliferation. Eight eyes presented pupillary membrane, whereas 14 showed lens cell proliferation. Out of eight eyes with pupillary membrane, seven occurred in the <7 mo age group. The difference between the <7 mo age group and the 2-5 y/o or >5 y/o age group was significant (p=0.01). Lens cell proliferation was more frequent in the <7 mo and 2-5 y/o age groups, but the difference was significant only between the < 7 mo age group and >5 y/o age group (p=0.040). Glaucoma and glaucoma suspect cases were not observed during the follow-up period. CONCLUSIONS: The main complication found in the study was visual axis opacification, which had a higher incidence in children operated on or before the age of 7 months.
Asunto(s)
Afaquia , Extracción de Catarata , Catarata , Glaucoma , Lentes Intraoculares , Niño , Humanos , Lactante , Preescolar , Recién Nacido , Extracción de Catarata/métodos , Implantación de Lentes Intraoculares/métodos , Brasil , Salud Pública , Resultado del Tratamiento , Agudeza Visual , Estudios de Seguimiento , Afaquia/cirugía , Glaucoma/cirugía , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugíaRESUMEN
ABSTRACT: We report herein a case of fitting with a photochromic silicone hydrogel contact lens under a rigid gas-permeable lens (piggyback system) for photophobia and low vision correction after traumatic aniridia and aphakia. A 40-year-old woman was referred to our practice for contact lens fitting in her right eye, which was left aphakic after an open globe injury. She also presented traumatic aniridia in the right eye, and her left eye had been previously eviscerated. A successful fitting was obtained with a photochromic silicone hydrogel (senofilcon A) contact lens, with a Dk/t of 121 × 10-9, under an aspheric design, +13.00 D rigid gas-permeable lens. The patient displayed visual acuity and contrast sensitivity improvement and reported decreased photophobia.
Asunto(s)
Afaquia , Lentes de Contacto , Lesiones Oculares , Baja Visión , Adulto , Femenino , Humanos , Fotofobia/etiología , Fotofobia/terapiaRESUMEN
La corrección quirúrgica de la afaquia se realiza mediante varias técnicas que permiten fijar los lentes intraoculares en la cámara posterior, suturados al sulcus ciliar o por fijación transescleral de las hápticas sin suturas. El cirujano determina cuándo, dónde y cómo, además del tipo de lente a implantar. Se presenta un paciente con una afaquia traumática del ojo izquierdo, con agudeza visual sin corrección de cuenta dedos a un metro y refracción dinámica de +8,00 dioptrías con agudeza visual mejor corregida de 0,8 por cartilla de Snellen. Tensión ocular de 16 mmHg. En el examen biomicroscópico con lámpara de hendidura del ojo izquierdo se observó midriasis traumática. Se le realizó examen con biomicroscopia indirecta y resultó sin alteraciones. Se implantó el lente intraocular de tres piezas (Tecnis ZA9003) de la cámara posterior y se fijaron las hápticas a la esclera sin utilizar suturas. Al mes de la cirugía la agudeza visual mejor corregida fue la unidad de visión(AU)
Surgical aphakia correction is based on several techniques allowing to fix intraocular lenses in the posterior chamber, sutured to the ciliary sulcus or by sutureless transcleral fixation of the haptics. The surgeon will decide when, where and how, as well as the lens type to implant. A case is presented of a male patient with traumatic aphakia of his left eye, finger counting uncorrected visual acuity at one meter and dynamic refraction of +8.00 diopters with best corrected visual acuity of 0.8 by the Snellen chart. Ocular tension was 16 mmHg. Biomicroscopic slit lamp examination of the left eye found traumatic mydriasis. Indirect biomicroscopy did not find any alteration. A three-piece intraocular lens (Tecnis ZA9003) was implanted in the posterior chamber, fixing the haptics to the sclera without the use of sutures. One month after surgery, best corrected visual acuity was the vision unit(AU)
Asunto(s)
Humanos , Masculino , Afaquia/etiología , Midriasis/diagnóstico , Microscopía con Lámpara de Hendidura/métodos , Lentes IntraocularesRESUMEN
Objetivo: Comparar los resultados refractivos del implante secundario de lentes intraoculares rígidos de la cámara anterior con apoyo angular y de lentes intraoculares plegables de la cámara posterior suturados a iris. Métodos: Se realizó un estudio casi experimental con control no equivalente (cohorte histórica). Se estudiaron 50 pacientes (50 ojos) con afaquia e inadecuado soporte capsular después de la cirugía de catarata, a quienes se les realizó implante secundario de lente intraocular con dos técnicas diferentes: lente intraocular en la cámara anterior con apoyo angular (25 ojos) y lente intraocular plegable de la cámara posterior suturado a iris (25 ojos). Resultados: Se observó que en el grupo de pacientes tratados con lente intraocular suturado a iris el porcentaje de pacientes con una visión de 20/40 o más fue significativamente superior (96,0 por ciento vs. 60,0 por ciento, p= 0,000) en los resultados refractivos obtenidos según el grupo de tratamiento. En el grupo A predominaron los pacientes que quedaron emétropes, seguidos de los pacientes miopes. En el grupo B predominaron los pacientes miopes y a diferencia del grupo anterior ningún paciente quedó hipermétrope. Conclusiones: La lente intraocular plegable de la cámara posterior suturada a iris mostró ser más eficaz, indujo menos astigmatismo y fue mejor en la predictibilidad de la esfera en un rango estricto de ± 1,00 dioptrías(AU)
Objective: Compare the refractive results of secondary implantation of rigid angle-supported intraocular lenses in the anterior chamber and foldable iris-suture-fixated intraocular lenses in the posterior chamber. Methods: A quasi-experimental non-equivalent control (historical cohort) study was conducted of 50 patients (50 eyes) with aphakia and inadequate capsular support after cataract surgery, who underwent secondary intraocular lens implantation with two different techniques: angle-supported intraocular lens in the anterior chamber (25 eyes) and foldable iris-suture-fixated intraocular lens in the posterior chamber (25 eyes). Results: In the group treated with iris-suture-fixated intraocular lens implantation the percentage of patients with 20/40 vision or more was significantly higher (96.0 percent vs. 60.0 percent, p= 0.000) in the refractive results obtained for each treatment group. In Group A a predominance was found of emmetropic, followed by myopic patients. In Group B myopic patients prevailed and unlike the other group no patient was hyperopic. Conclusions: Foldable iris-suture-fixated posterior chamber intraocular lenses proved more effective, induced less astigmatism and displayed better sphere predictability in a strict range of ± 1.00 diopters(AU)
Asunto(s)
Humanos , Afaquia/etiología , Astigmatismo/etiología , Implantación de Lentes Intraoculares/métodos , Cámara Anterior/cirugía , Estudios de CohortesRESUMEN
A 29-gauge model test fine needle is used to create a beveled intrascleral tunnel; with microforceps, a 6-0 polypropylene suture is placed in the bore of the needle, which is used as a guide to pass and externalize the monofilament through the sclera. This maneuver is repeated by passing the suture ends through the intraocular lens (IOL) eyelets. The folded IOL is inserted and centered, the sutures are cut, and the flanges are created by thermocautery and inserted into the scleral tunnel. This technique was performed on 7 patients and visual acuity was recorded. The 4-flanged technique for scleral fixation using a 4-eyelet IOL was an effective and a safe treatment in the setting of aphakia.
Asunto(s)
Afaquia , Lentes Intraoculares , Afaquia/cirugía , Humanos , Implantación de Lentes Intraoculares , Esclerótica/cirugía , Técnicas de Sutura , SuturasRESUMEN
AIMS: Intraoperative complications in cataract surgery are more common in diabetic patients. Solving aphakia in these circumstances remains a challenge, as the scleral structure has been shown to be different in diabetes. This study aims to analyze the role of a secondary sutureless scleral intraocular lens (IOL) flanged fixation in diabetic patients without capsular support and to compare the anatomical and functional outcomes using a 30 gauge (G) ultrathin wall needle vs. a 27G needle. METHODS: Retrospective, observational cohort study. 105 eyes (105 patients) who underwent PPV with secondary IOL fixation using a sutureless 27G (n = 51) or a 30G ultrathin wall (UTW) needle technique (n = 54) and had a 24 months postoperative follow up. Consecutive patients' records were reviewed for lens stability and centration parameters, intra- and postoperative complications at 7 days, 1, 3, 6, 12, and 24 months after surgery. Correlations between outcome measures and needle size (27G vs. 30G UTW) were analyzed. RESULTS: IOL displacement occurred in 30 patients (41.2%) in the 27G group and did not occur in the 30G UTW needle group (p < 0.001). Mean time until IOL displacement was 10.5 ± 7.0 months (range: 7 days-24 months). IOL centricity was significantly better in the 30G ultrathin wall needle group compared to 27 G (p = 0.001). Additional surgical interventions were necessary only in the 27G group (n = 14). CONCLUSIONS: Sutureless IOL flanged technique using a 30G UTW needle is more predictable and has less complications in aphakic diabetic patients, compared to a 27G needle technique.
Asunto(s)
Diabetes Mellitus/cirugía , Retinopatía Diabética/cirugía , Implantación de Lentes Intraoculares/instrumentación , Agujas , Procedimientos Quirúrgicos sin Sutura/instrumentación , Adulto , Anciano , Afaquia/epidemiología , Afaquia/cirugía , Argentina/epidemiología , Estudios de Cohortes , Diabetes Mellitus/epidemiología , Retinopatía Diabética/epidemiología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Implantación de Lentes Intraoculares/efectos adversos , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Masculino , Persona de Mediana Edad , Agujas/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Esclerótica/cirugía , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Procedimientos Quirúrgicos sin Sutura/métodos , Agudeza VisualRESUMEN
PURPOSE: To describe 2 sporadic Mexican patients having congenital bilateral, total sclerocornea, aphakia, and microphthalmia associated with novel mutations in the FOXE3 gene. METHODS: Two affected individuals with congenital bilateral, total sclerocornea, aphakia, and microphthalmia underwent detailed examinations including slit-lamp examination, visual acuity, and intraocular pressure measurements. Ocular ultrasonography and ultrasound biomicroscopy were performed. Genomic DNA was isolated from blood leukocytes in each subject, and molecular analysis of the FOXE3 gene was performed. For cosegregation analysis, presumable pathogenic variants were tested by Sanger sequencing in parental DNA. RESULTS: Molecular screening of FOXE3 was performed in 2 cases with congenital bilateral, total sclerocornea, aphakia, and microphthalmia. In patient 1, genetic analysis demonstrated a novel homozygous c.291C>G (p.Ile97Met) FOXE3 pathogenic variant. In patient 2, compound heterozygosity for the novel c.387C>G (p.Phe129Leu) transversion and for the previously reported c.244A>G (p.Met82Val) transition, was recognized. CONCLUSIONS: The sclerocornea-microphthalmia-aphakia complex is a severe malformative ocular phenotype resulting from mutations in the FOXE3 transcription factor. To date, patients from at least 14 families with this uncommon ocular disorder have been described. The identification of 2 novel pathogenic variants in our patients expands the mutational spectrum in FOXE3-related congenital eye disorders. In addition, we performed a review of the clinical and genotypic characteristics of all published patients carrying biallelic FOXE3 mutations.
Asunto(s)
Afaquia/genética , Córnea/anomalías , Enfermedades de la Córnea/genética , Factores de Transcripción Forkhead/genética , Microftalmía/genética , Mutación , Afaquia/diagnóstico , Niño , Consanguinidad , Enfermedades de la Córnea/diagnóstico , Análisis Mutacional de ADN , Femenino , Genotipo , Heterocigoto , Humanos , Recién Nacido , Masculino , Microftalmía/diagnóstico , Microscopía Acústica , Reacción en Cadena de la PolimerasaRESUMEN
Para la corrección quirúrgica de la afaquia existen en la actualidad varias técnicas quirúrgicas que permiten fijar los lentes intraoculares plegables o rígidos en cámara posterior suturados al iris o al sulcus ciliar. En estas circunstancias el cirujano determinará cuándo, dónde y el tipo de lente mejor a implantar. Se presenta un paciente con una afaquia traumática del ojo izquierdo, con agudeza visual sin corrección de movimiento de mano a 1 m. Se le realizó implante secundario de lente intraocular plegable de cámara posterior suturada al iris. En el examen biomicroscópico en lámpara de hendidura del ojo izquierdo se observó midriasis media paralítica, refracción dinámica de +11,00 (0,6) y tensión ocular normal. Se le realizó examen por bimicroscopía indirecta sin alteración. Al mes de operado la agudeza visual mejor corregida alcanzó la unidad de visión. Las complicaciones presentadas fueron ovalización de la pupila y depósitos de pigmentos de iris en el lente intraocular(AU)
There are several surgical techniques for the surgical correction of aphakia, which allow fixing foldable or rigid intraocular lenses in the posterior chamber by suturing them to iris or to ciliary sulcus. Under these circumstances, the surgeon will determine the time, the place and the type of lenses that is better to be implanted. This is a patient with traumatic aphakia in his left eye, with visual acuity without correction equals to hand movement at 1 m distance. He was performed a secondary implantation of a iris-sutured posterior chamber foldable intraocular lens. In the biomicroscopic exam of the left eye using the slit lamp, there was observed mean paralytic midriasis, dynamic refraction of +11,00 (0.6) and normal ocular pressure. He also underwent an indirect biomicroscopy with no alteration. After a month of his surgery, the best corrected visual acuity reached the vision unit. The complications found were ovalization of pupil and iris pigment depots in the intraocular lens(AU)
Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Afaquia/complicaciones , Lentes Intraoculares Fáquicas/efectos adversos , Microscopía con Lámpara de HendiduraRESUMEN
Para la corrección quirúrgica de la afaquia existen en la actualidad varias técnicas quirúrgicas que permiten fijar los lentes intraoculares plegables o rígidos en cámara posterior suturados al iris o al sulcus ciliar. En estas circunstancias el cirujano determinará cuándo, dónde y el tipo de lente mejor a implantar. Se presenta un paciente con una afaquia traumática del ojo izquierdo, con agudeza visual sin corrección de movimiento de mano a 1 m. Se le realizó implante secundario de lente intraocular plegable de cámara posterior suturada al iris. En el examen biomicroscópico en lámpara de hendidura del ojo izquierdo se observó midriasis media paralítica, refracción dinámica de +11,00 (0,6) y tensión ocular normal. Se le realizó examen por bimicroscopía indirecta sin alteración. Al mes de operado la agudeza visual mejor corregida alcanzó la unidad de visión. Las complicaciones presentadas fueron ovalización de la pupila y depósitos de pigmentos de iris en el lente intraocular(AU)
There are several surgical techniques for the surgical correction of aphakia, which allow fixing foldable or rigid intraocular lenses in the posterior chamber by suturing them to iris or to ciliary sulcus. Under these circumstances, the surgeon will determine the time, the place and the type of lenses that is better to be implanted. This is a patient with traumatic aphakia in his left eye, with visual acuity without correction equals to hand movement at 1 m distance. He was performed a secondary implantation of a iris-sutured posterior chamber foldable intraocular lens. In the biomicroscopic exam of the left eye using the slit lamp, there was observed mean paralytic midriasis, dynamic refraction of +11,00 (0.6) and normal ocular pressure. He also underwent an indirect biomicroscopy with no alteration. After a month of his surgery, the best corrected visual acuity reached the vision unit. The complications found were ovalization of pupil and iris pigment depots in the intraocular lens(AU)
Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Afaquia/complicaciones , Lentes Intraoculares Fáquicas/efectos adversos , Microscopía con Lámpara de Hendidura/estadística & datos numéricosRESUMEN
OBJETIVOS -Generar recomendaciones basadas en la mejor evidencia disponible acerca del manejo de personas con vicios de refracción. -Entregar recomendaciones acerca del diagnóstico y tratamiento de personas mayores de 65 años con vicios de refracción. TIPO DE PACIENTES Y ESCENARIO CLÍNICO -Diagnóstico y tratamiento de personas de 65 años y más con vicios de refracción que reciben atención en el nivel primario, secundario en el sector público y privado de salud USUARIOS DE LA GUÍA -Todos los profesionales de salud con responsabilidades en personas con vicios de refracción: Médicos de Atención Primaria de Salud y oftalmólogos del nivel secundario y terciario de atención y a tecnólogos médicos de oftalmología. METODOLOGÍA Las recomendaciones de esta Guía fueron elaboradas de acuerdo con el sistema "Grading of Recommendations Assessment, Development, and Evaluation" (GRADE). Luego de priorizadas las preguntas a responder, se realizó la búsqueda y la síntesis de evidencia, para finalmente generar las recomendaciones a través del juicio del Panel de Expertos. La búsqueda y selección de la evidencia de esta Guía se basó en un método sistemático, transparente y reproducible. Una vez seleccionada la evidencia, se resumió en un formato claro y conciso que permitiera al Grupo Elaborador realizar los juicios respecto a la calidad de dicha evidencia, el balance entre los riesgos y beneficios asociados a la intervención o calidad de una prueba, un tratamiento, los valores y preferencias de los pacientes, y los costos derivados de su implementación.
Asunto(s)
Anciano , Errores de Refracción , Astigmatismo , Pruebas de Visión , Anciano , Guía de Práctica Clínica , Lentes de Contacto , Oftalmólogos , Hiperopía , Lentes , Miopía , Afaquia , Anisometropía , Chile , QueratoconoRESUMEN
OBJETIVOS -Generar recomendaciones basadas en la mejor evidencia disponible acerca del manejo de desprendimiento de retina regmatógeno no traumático. -Entregar recomendaciones para el diagnóstico y tratamiento de personas con desprendimiento de retina regmatógeno no traumático. TIPO DE PACIENTES Y ESCENARIO CLÍNICO Personas con desprendimiento de retina regmatógeno no traumático que reciben atención en el nivel secundario y terciario de salud en el sector público y privado de salud. USUARIOS DE LA GUÍA Todos los profesionales de salud con responsabilidades en personas con desprendimiento de retina regmatógeno no traumático: Médicos de Atención Primaria de Salud y de Servicios de Urgencia, y Oftalmólogos del nivel secundario y terciario de atención. METODOLOGÍA Las recomendaciones de esta Guía fueron elaboradas de acuerdo con el sistema "Grading of Recommendations Assessment, Development, and Evaluation" (GRADE). Luego de priorizadas las preguntas a responder, se realizó la búsqueda y la síntesis de evidencia, para finalmente generar las recomendaciones a través del juicio del Panel de Expertos. La búsqueda y selección de la evidencia de esta Guía se basó en un método sistemático, transparente y reproducible. Una vez seleccionada la evidencia, se resumió en un formato claro y conciso que permitiera al Grupo Elaborador realizar los juicios respecto a la calidad de dicha evidencia, el balance entre los riesgos y beneficios asociados a la intervención o calidad de una prueba, un tratamiento, los valores y preferencias de los pacientes, y los costos derivados de su implementación.
Asunto(s)
Vitrectomía , Desprendimiento de Retina , Lesiones Oculares , Guía de Práctica Clínica , Facoemulsificación , Traumatismos del Nervio Óptico , Fondo de Ojo , Afaquia , Chile , Ultrasonografía , Seudofaquia , MiopíaRESUMEN
PURPOSE: To evaluate the outcomes of three different surgical techniques for foldable posterior chamber intraocular lens (PCIOL) implantation in vitrectomized eyes without capsular support. METHODS: A total of 60 patients with aphakic and vitrectomized eyes without capsular support were enrolled. All patients underwent three-piece foldable PCIOL implantation into the posterior chamber through a small corneal incision. Transscleral fixation (TSF), iris fixation (IF), and intrascleral tunnel fixation (ISF) surgical techniques were performed. RESULTS: Postoperative PCIOL subluxation or dislocation occurred in one case in the TSF group and two cases in the ISF group. Intraoperative PCIOL dislocation occurred in two patients in the IF group. The incidence of temporary postoperative complications, such as mild intraocular hemorrhage and cystoid macular edema, was higher in the ISF group. No statistically significant difference in PCIOL-related astigmatism was observed between groups. Visual acuity improved in all groups. CONCLUSIONS: Postoperative outcomes were comparable between TSF, IF, and ISF for PCIOL in vitrectomized eyes without capsular support.
Asunto(s)
Afaquia/cirugía , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Vitrectomía/métodos , Anciano , Astigmatismo/etiología , Córnea/cirugía , Femenino , Humanos , Iris/cirugía , Implantación de Lentes Intraoculares/efectos adversos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Esclerótica/cirugía , Estadísticas no Paramétricas , Técnicas de Sutura , Factores de Tiempo , Resultado del Tratamiento , Agudeza Visual , Vitrectomía/efectos adversosRESUMEN
ABSTRACT Purpose: To evaluate the outcomes of three different surgical techniques for foldable posterior chamber intraocular lens (PCIOL) implantation in vitrectomized eyes without capsular support. Methods: A total of 60 patients with aphakic and vitrectomized eyes without capsular support were enrolled. All patients underwent three-piece foldable PCIOL implantation into the posterior chamber through a small corneal incision. Transscleral fixation (TSF), iris fixation (IF), and intrascleral tunnel fixation (ISF) surgical techniques were performed. Results: Postoperative PCIOL subluxation or dislocation occurred in one case in the TSF group and two cases in the ISF group. Intraoperative PCIOL dislocation occurred in two patients in the IF group. The incidence of temporary postoperative complications, such as mild intraocular hemorrhage and cystoid macular edema, was higher in the ISF group. No statistically significant difference in PCIOL-related astigmatism was observed between groups. Visual acuity improved in all groups. Conclusions: Postoperative outcomes were comparable between TSF, IF, and ISF for PCIOL in vitrectomized eyes without capsular support.
RESUMO Objetivo: Avaliar os resultados de três diferentes técnicas cirúrgicas para implantação da lente intraocular de câmara posterior (PCIOL) dobrável em olhos vitrectomizados sem apoio capsular. Métodos: Um total de 60 olhos de 60 pacientes afácicos vitrectomizados, sem apoio capsular foram inscritos. Todos os pacientes foram submetidos ao implante de PCIOL dobrável de três peças na câmara posterior, através de uma pequena incisão na córnea. Foram utilizados as técnicas cirúrgicas de fixação transescleral (TSF), fixação iriana (IF) e túnel de fixação intraescleral (ISF). Resultados: Subluxação ou luxação da PCIOL ocorreu em um caso no grupo TSF e em dois casos no grupo ISF. Deslocamentos intraoperatórios da PCIOL ocorram em dois pacientes no grupo IF. Frequência de complicações pós-operatórias temporárias como hemorragia intraocular leve e edema macular cistóide foi maior no grupo ISF. Não houve diferença estatisticamente significativa do astigmatismo relacionado à PCIOL entre os grupos. A acuidade visual melhorou em todos os grupos. Conclusões: Nenhuma das três técnicas cirúrgicas teve destaque em termos de resultados cirúrgicos comparativos.
Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Afaquia/cirugía , Vitrectomía/métodos , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares , Complicaciones Posoperatorias , Astigmatismo/etiología , Esclerótica/cirugía , Factores de Tiempo , Vitrectomía/efectos adversos , Agudeza Visual , Iris/cirugía , Estudios Retrospectivos , Técnicas de Sutura , Resultado del Tratamiento , Estadísticas no Paramétricas , Córnea/cirugía , Implantación de Lentes Intraoculares/efectos adversosRESUMEN
Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a novel surgical technique for the management of an aphakic eye with traumatic aniridia for a patient who underwent transscleral fixation of a custom-tailored artificial iris prosthesis combined with a rigid intraocular lens (IOL). Tight suturing of the IOL haptic eyelets on the silicone iris prosthesis and fixation of such a complex to the scleral wall may provide excellent cosmetic and functional outcomes in aphakic eyes with aniridia.
Asunto(s)
Aniridia/cirugía , Afaquia/cirugía , Iris/cirugía , Lentes Intraoculares , Prótesis e Implantes , Esclerótica/cirugía , Aniridia/etiología , Afaquia/etiología , Lesiones Oculares/cirugía , Femenino , Humanos , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Diseño de Prótesis , Resultado del Tratamiento , Agudeza VisualRESUMEN
ABSTRACT Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a novel surgical technique for the management of an aphakic eye with traumatic aniridia for a patient who underwent transscleral fixation of a custom-tailored artificial iris prosthesis combined with a rigid intraocular lens (IOL). Tight suturing of the IOL haptic eyelets on the silicone iris prosthesis and fixation of such a complex to the scleral wall may provide excellent cosmetic and functional outcomes in aphakic eyes with aniridia.
RESUMO Aniridia pós-traumática combinada com afacia pode ser observada após lesões do globo ocular. Além do ponto de vista estético, a perda parcial ou total do tecido da íris também pode estar relacionada com vários graus de ofuscamento e fotofobia. Estes pacientes sofrem de deficiência visual grave secundária a afacia. Relata-se uma técnica cirúrgica inovadora para tratamento de um olho com afacia associada à aniridia traumática que foi submetido à fixação transescleral de uma prótese de íris artificial feita sob medida combinada com uma lente intraocular rígida (IOL). A sutura das alças da IOL sobre a prótese iriana de silicone, e a fixação desse complexo na parede escleral podem proporcionar excelente resultado estético e funcional em olhos afácicos com aniridia.