Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24.850
Filtrar
1.
BMC Med Inform Decis Mak ; 24(1): 131, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773484

RESUMEN

INTRODUCTION: Open globe injuries (OGI) represent a main preventable reason for blindness and visual impairment, particularly in developing countries. The goal of this study is evaluating key variables affecting the prognosis of open globe injuries and validating internally and comparing different machine learning models to estimate final visual acuity. MATERIALS AND METHODS: We reviewed three hundred patients with open globe injuries receiving treatment at Khatam-Al-Anbia Hospital in Iran from 2020 to 2022. Age, sex, type of trauma, initial VA grade, relative afferent pupillary defect (RAPD), zone of trauma, traumatic cataract, traumatic optic neuropathy (TON), intraocular foreign body (IOFB), retinal detachment (RD), endophthalmitis, and ocular trauma score (OTS) grade were the input features. We calculated univariate and multivariate regression models to assess the association of different features with visual acuity (VA) outcomes. We predicted visual acuity using ten supervised machine learning algorithms including multinomial logistic regression (MLR), support vector machines (SVM), K-nearest neighbors (KNN), naïve bayes (NB), decision tree (DT), random forest (RF), bagging (BG), adaptive boosting (ADA), artificial neural networks (ANN), and extreme gradient boosting (XGB). Accuracy, positive predictive value (PPV), recall, F-score, brier score (BS), Matthew correlation coefficient (MCC), receiver operating characteristic (AUC-ROC), and calibration plot were used to assess how well machine learning algorithms performed in predicting the final VA. RESULTS: The artificial neural network (ANN) model had the best accuracy to predict the final VA. The sensitivity, F1 score, PPV, accuracy, and MCC of the ANN model were 0.81, 0.85, 0.89, 0.93, and 0.81, respectively. In addition, the estimated AUC-ROC and AUR-PRC of the ANN model for OGI patients were 0.96 and 0.91, respectively. The brier score and calibration log-loss for the ANN model was 0.201 and 0.232, respectively. CONCLUSION: As classic and ensemble ML models were compared, results shows that the ANN model was the best. As a result, the framework that has been presented may be regarded as a good substitute for predicting the final VA in OGI patients. Excellent predictive accuracy was shown by the open globe injury model developed in this study, which should be helpful to provide clinical advice to patients and making clinical decisions concerning the management of open globe injuries.


Asunto(s)
Lesiones Oculares Penetrantes , Aprendizaje Automático , Agudeza Visual , Humanos , Masculino , Femenino , Adulto , Pronóstico , Persona de Mediana Edad , Agudeza Visual/fisiología , Irán , Adulto Joven , Adolescente , Redes Neurales de la Computación , Anciano
3.
Transl Vis Sci Technol ; 13(5): 17, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38776109

RESUMEN

Purpose: This study aimed to develop artificial intelligence models for predicting postoperative functional outcomes in patients with rhegmatogenous retinal detachment (RRD). Methods: A retrospective review and data extraction were conducted on 184 patients diagnosed with RRD who underwent pars plana vitrectomy (PPV) and gas tamponade. The primary outcome was the best-corrected visual acuity (BCVA) at three months after the surgery. Those with a BCVA of less than 6/18 Snellen acuity were classified into a vision impairment group. A deep learning model was developed using presurgical predictors, including ultra-widefield fundus images, structural optical coherence tomography (OCT) images of the macular region, age, gender, and preoperative BCVA. A fusion method was used to capture the interaction between different modalities during model construction. Results: Among the participants, 74 (40%) still had vision impairment after the treatment. There were significant differences in age, gender, presurgical BCVA, intraocular pressure, macular detachment, and extension of retinal detachment between the vision impairment and vision non-impairment groups. The multimodal fusion model achieved a mean area under the curve (AUC) of 0.91, with a mean accuracy of 0.86, sensitivity of 0.94, and specificity of 0.80. Heatmaps revealed that the macular involvement was the most active area, as observed in both the OCT and ultra-widefield images. Conclusions: This pilot study demonstrates that artificial intelligence techniques can achieve a high AUC for predicting functional outcomes after RRD surgery, even with a small sample size. Machine learning methods identified The macular region as the most active region. Translational Relevance: Multimodal fusion models have the potential to assist clinicians in predicting postoperative visual outcomes prior to undergoing PPV.


Asunto(s)
Inteligencia Artificial , Desprendimiento de Retina , Tomografía de Coherencia Óptica , Agudeza Visual , Vitrectomía , Humanos , Desprendimiento de Retina/cirugía , Femenino , Masculino , Estudios Retrospectivos , Persona de Mediana Edad , Agudeza Visual/fisiología , Vitrectomía/métodos , Tomografía de Coherencia Óptica/métodos , Anciano , Adulto , Endotaponamiento , Resultado del Tratamiento , Aprendizaje Profundo
4.
JAMA Ophthalmol ; 142(5): e234933, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38770960

RESUMEN

This case report discusses a diagnosis of X-linked Alport syndrome in a 54-year-old male patient who presented with a lamellar macular hole in his left eye.


Asunto(s)
Perforaciones de la Retina , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Perforaciones de la Retina/diagnóstico , Masculino , Persona de Mediana Edad , Agudeza Visual/fisiología , Vitrectomía
5.
BMC Ophthalmol ; 24(1): 205, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711013

RESUMEN

PURPOSE: To summarize the outcomes of corneal sight rehabilitating surgery in Stevens-Johnson syndrome (SJS). METHODS: This is a retrospective analysis of a consecutive case series. Twenty-four eyes of 18 SJS patients were included in this study. The ocular parameters, surgical procedures, postoperative complications, and additional treatments of the cases were reviewed. RESULTS: A total of 29 corneal sight rehabilitating surgeries, which consists of 9 keratoplasties, 8 Keratolimbal allograft (KLAL) and 12 combined surgeries (keratoplasty and KLAL simultaneously) were performed on the 24 eyes. All patients were treated with glucocorticoid eyedrops and tacrolimus eyedrops for anti-rejection treatment without combining systemic immunosuppression, except two patients who were prescribed prednisone tablets for the management of systemic conditions. The mean follow-up period was 50.6 ± 28.1 months. The optimal visual acuity (VA) (0.74 ± 0.60 logarithm of the minimum angle of resolution [logMAR]) and endpoint VA (1.06 ± 0.82 logMAR) were both significantly better than the preoperative VA (1.96 ± 0.43 logMAR) (95% CI, p = 0.000). 57.1% patients (8/14) were no longer in the low vision spectrum, and 88.9% patients (8/9) were no longer blind. The mean epithelialization time was 7.1 ± 7.6 weeks. The success rate was 86.7%. Additional treatments for improving epithelialization included administration of serum eyedrops (n = 10), contact lens (n = 15), amniotic membrane transplantation (n = 6), and tarsorrhaphy (n = 8). Complications included delayed epithelialization (n = 4, over 12 weeks), glaucoma (n = 11), and severe allograft opacity (n = 4). Only one graft rejection was observed. CONCLUSIONS: Keratoplasty and KLAL can remarkably enhance VA and improve low vision or even eliminate blindness for ocular complications of SJS. The outcome of the surgeries was correlated with the preoperative ocular situation and choice of operative methods.


Asunto(s)
Enfermedades de la Córnea , Síndrome de Stevens-Johnson , Agudeza Visual , Humanos , Síndrome de Stevens-Johnson/cirugía , Síndrome de Stevens-Johnson/fisiopatología , Estudios Retrospectivos , Femenino , Masculino , Adulto , Agudeza Visual/fisiología , Persona de Mediana Edad , Adulto Joven , Adolescente , Enfermedades de la Córnea/cirugía , Enfermedades de la Córnea/fisiopatología , Resultado del Tratamiento , Niño , Trasplante de Córnea/métodos , Estudios de Seguimiento , Queratoplastia Penetrante/métodos , Complicaciones Posoperatorias , Limbo de la Córnea/cirugía
6.
BMC Ophthalmol ; 24(1): 207, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711043

RESUMEN

PURPOSE: To understand the ocular biometric parameters characteristics and refractive errors in 3-to 6-year-old preschool children in Chengdu, China, and to investigate the prevalence of refractive errors. METHOD: A school-based cross-sectional study was conducted in Chengdu from 2020 to2022 with a total of 666 kindergartens. All children were measured by non-cycloplegic autorefraction and uncorrected visual acuity (UCVA) and ocular biometric parameters. Finally, univariate linear regression models were used to analyze the relationship between ocular biometric parameters and refraction. RESULTS: A total of 108,578 preschool children aged 3-6 underwent examinations, revealing a myopia prevalence of 6.1%. The mean axial length (AL), keratometry (K), corneal radius (CR), axial length/corneal radius (AL/CR) Ratio, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and vitreous chamber depth (VCD) were 22.35 ± 0.69 mm, 43.35 ± 1.58 D, 7.80 ± 0.28 mm, 2.87 ± 0.08, 533.31 ± 32.51 µm, 2.70 ± 0.28 mm, 3.91 ± 0.27 mm, and 15.20 ± 0.68 mm, respectively. With increasing age, AL, CR, AL/CR ratio, CCT, ACD, LT, and VCD also increased. Regardless of age, males consistently exhibited longer AL, flatter corneal curvature, shallower ACD, thicker CCT, thinner LT, and longer VCD compared to females. AL, K, CR, LT, and VCD all showed significant linear relationships with SE (all P < 0.001) in univariate linear regression analysis after adjusting for gender and age. CONCLUSION: The prevalence of myopia among preschool children aged 3-6 in Chengdu is relatively low. Ocular biometric parameters affecting refractive errors include AL, K, CR, LT, and VCD. The preschool period serves as a critical phase for myopia prevention and control.


Asunto(s)
Biometría , Refracción Ocular , Agudeza Visual , Humanos , Femenino , Masculino , Estudios Transversales , China/epidemiología , Refracción Ocular/fisiología , Preescolar , Niño , Agudeza Visual/fisiología , Prevalencia , Longitud Axial del Ojo , Córnea/patología , Córnea/anatomía & histología , Errores de Refracción/epidemiología , Errores de Refracción/fisiopatología , Cámara Anterior/diagnóstico por imagen , Cámara Anterior/patología , Miopía/epidemiología , Miopía/fisiopatología
7.
BMC Ophthalmol ; 24(1): 206, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711059

RESUMEN

PURPOSE: The main objective is to quantify the lens nuclear opacity using spectral-domain optical coherence tomography (SD-OCT) and to evaluate its association with Lens Opacities Classification System III (LOCS-III) system, lens thickness (LT), and surgical parameters. The secondary objective is to assess the diagnostic model performance for hard nuclear cataract. METHODS: This study included 70 eyes of 57 adults with cataract, with 49 (70%) and 21 (30%) in training and validation cohort, respectively. Correlations of the average nuclear density (AND) /maximum nuclear density (MND) with LOCS-III scores, LT, and surgical parameters were analyzed. Univariate and multivariate logistic regression analysis, receiver operating characteristic curves and calibration curves were performed for the diagnostic of hard nuclear cataract. RESULTS: The pre-operative uncorrected distance visual acuity (UDVA), intraocular pressure (IOP), mean axial length (AL), and LT were 1.20 ± 0.47 log MAR, 15.50 ± 2.87 mmHg, 27.34 ± 3.77 mm and 4.32 ± 0.45 mm, respectively. The average nuclear opalescence (NO) and nuclear colour (NC) scores were 3.61 ± 0.94 and 3.50 ± 0.91 (ranging from 1.00 to 6.90), respectively. The average AND and MND were 137.94 ± 17.01 and 230.01 ± 8.91, respectively. NC and NO scores both significantly correlated with the AND (rNC = 0.733, p = 0.000; rNO = 0.755, p = 0.000) and MND (rNC = 0.643, p = 0.000; rNO = 0.634, p = 0.000). In the training cohort, the area under the curve (AUC) of the model was 0.769 (P < 0.001, 95%CI 0.620-0.919), which had a good degree of differentiation (Fig. 2a). The calibration curve showed good agreement between predicted and actual probability. CONCLUSION: The nuclear density measurement on SD-OCT images can serve as an objective and reliable indicator for quantifying nuclear density.


Asunto(s)
Catarata , Núcleo del Cristalino , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Femenino , Masculino , Tomografía de Coherencia Óptica/métodos , Catarata/diagnóstico , Anciano , Persona de Mediana Edad , Núcleo del Cristalino/patología , Núcleo del Cristalino/diagnóstico por imagen , Agudeza Visual/fisiología , Curva ROC , Estudios Retrospectivos , Facoemulsificación , Anciano de 80 o más Años , Adulto , Cristalino/diagnóstico por imagen , Cristalino/patología
8.
Aerosp Med Hum Perform ; 95(5): 278-281, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38715272

RESUMEN

BACKGROUND: This article documents the stability of photorefractive keratectomy (PRK) and laser-assisted in situ keratomileusis (LASIK) in two astronauts during 6-mo missions to the International Space Station.CASE REPORTS: Ocular examinations including visual acuity, cycloplegic refraction, slit lamp examination, corneal topography, central corneal thickness, optical biometry (axial length/keratometry), applanation tonometry, and dilated fundus examination were performed on each astronaut before and after their missions, and in-flight visual acuity testing was done on flight day 30, 90, and R-30 (30 d before return). They were also questioned regarding visual changes during flight.DISCUSSION: We documented stable vision in both PRK and LASIK astronauts during liftoff, entry into microgravity, 6 mo on the International Space Station, descent, and landing. Our results suggest that both PRK and LASIK are stable and well tolerated during long-duration spaceflight.Gibson CR, Mader TH, Lipsky W, Schallhorn SC, Tarver WJ, Suresh R, Hauge TN, Brunstetter TJ. Photorefractive keratectomy and laser-assisted in situ keratomileusis on 6-month space missions. Aerosp Med Hum Perform. 2024; 95(5):278-281.


Asunto(s)
Astronautas , Queratomileusis por Láser In Situ , Queratectomía Fotorrefractiva , Vuelo Espacial , Agudeza Visual , Humanos , Queratectomía Fotorrefractiva/métodos , Queratomileusis por Láser In Situ/métodos , Masculino , Adulto , Agudeza Visual/fisiología , Medicina Aeroespacial , Persona de Mediana Edad , Miopía/cirugía , Miopía/fisiopatología
9.
Arq Bras Oftalmol ; 87(3): e20230257, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38716966

RESUMEN

PURPOSE: This review emphasizes the effect of light on visual efficiency, the impact of different lighting focuses, types of lighting, and their influence on vision and productivity. Light sources and standards are intriguing subjects for ophthalmologists. Guidelines regarding the level of lighting influence on visual activities can enhance visual performance.Methods: This article was developed based on literature reviews, with a bibliographic survey conducted in databases such as PubMed, MEDLINE, Web of Science, Embase, LILACS, and SciELO. RESULTS: Provides recommendations for understanding information regarding the influence of lighting on visual performance. CONCLUSION: Proper workplace lighting is crucial for improving visual efficiency, safety, productivity, and worker health. Efficient workplace lighting should avoid light sources directed towards the worker's face, prevent harmful glare, be more intense in the work area, and uniform in the rest of the room. Ophthalmologists should be knowledgeable about and provide guidance on correct lighting to ensure patient comfort and satisfaction with visual correction.


Asunto(s)
Iluminación , Humanos , Visión Ocular/fisiología , Agudeza Visual/fisiología , Lugar de Trabajo , Salud Laboral , Deslumbramiento , Luz
10.
J Refract Surg ; 40(5): e313-e320, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717079

RESUMEN

PURPOSE: To assess the clinical outcomes and safety profiles of patients who underwent immediate sequential bilateral phakic lens surgery. METHODS: This retrospective multicenter study included 254 consecutive patients (508 eyes) who underwent bilateral same-day Implantable Collamer Lens (ICL) (STAAR Surgical) surgery. The authors focused on 1-year postoperative clinical outcomes and adverse events. RESULTS: In the initial cohort, 176 patients (352 eyes) met inclusion criteria. Of these, 335 eyes underwent myopic ICL placement, and 17 eyes received a hyperopic ICL. Notably, 87% of eyes achieved ±0.50 diopters (D) and 95% achieved ±1.00 D of the intended refraction. One year postoperatively, 78% of eyes demonstrated optimal vaulting (250 to 750 µm), with a significant 19% reduction in vaulting observed over the 12 months (P < .001). Only minor adverse events, including early cataract formation (1 case), secondary toric ICL rotation (3 cases), and ICL exchange due to inappropriate vaulting (6 cases), were noted. CONCLUSIONS: The findings corroborate the safety and efficacy of immediate sequential bilateral phakic lens surgery and indicate its potential as a treatment option. The low incidence of minor adverse events further reinforces its favorable safety profile. [J Refract Surg. 2024;40(5):e313-e320.].


Asunto(s)
Hiperopía , Implantación de Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Agudeza Visual/fisiología , Femenino , Adulto , Miopía/cirugía , Miopía/fisiopatología , Refracción Ocular/fisiología , Hiperopía/cirugía , Hiperopía/fisiopatología , Adulto Joven , Resultado del Tratamiento , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios de Seguimiento , Adolescente
11.
J Refract Surg ; 40(5): e328-e335, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717080

RESUMEN

PURPOSE: To evaluate moderate to high astigmatism corrections on the outcomes of SmartSight lenticule extraction for myopic astigmatism with a new femtosecond laser system. METHODS: Two hundred ninety-two eyes consecutively treated for myopic astigmatism with astigmatism magnitude greater than 1.00 diopter (D) were evaluated at the 6-month follow-up visit. The mean age of the patients was 29 ± 6 years with a mean spherical equivalent of -5.06 ± 2.20 diopters (D) and a mean magnitude of refractive astigmatism of 1.74 ± 0.61 D. RESULTS: At 6 months, astigmatism was 0.10 ± 0.20 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively) were both 0.0 ± 0.1 logMAR. Differences between postoperative UDVA and preoperative CDVA and the change in CDVA were both +0.4 ± 0.7 lines better than preoperatively (P < .0003). CONCLUSIONS: Lenticule extraction treatment using Smart-Sight is safe and efficacious at 6 months. Findings suggest that moderate to high astigmatism improves after SmartSight lenticule extraction in the treatment of myopic astigmatism. [J Refract Surg. 2024;40(5):e328-e335.].


Asunto(s)
Astigmatismo , Sustancia Propia , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Agudeza Visual/fisiología , Estudios Retrospectivos , Adulto , Refracción Ocular/fisiología , Masculino , Femenino , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Sustancia Propia/cirugía , Láseres de Excímeros/uso terapéutico , Topografía de la Córnea , Estudios de Seguimiento , Resultado del Tratamiento , Cirugía Laser de Córnea/métodos
12.
J Refract Surg ; 40(5): e336-e343, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717081

RESUMEN

PURPOSE: To assess and compare the visual acuity and refractive outcomes of topography-guided laser in situ keratomileusis (LASIK) based on the fitting-shape-based refractive compensated and Phorcides software strategies. METHODS: Consecutive patients who underwent topography-guided LASIK were included in this study. Through double-masked simple randomization, patients were assigned to the Zhang & Zheng Auto-compensate Refraction (ZZ AR) group (the fitting-shape-based refractive compensated strategy using the ZZ AR calculator was used) or the Phorcides group (the topography analysis algorithm in Phorcides software [Phorcides LLC] was used). Only one eye per patient with binocular correction was randomly enrolled. The preoperative and postoperative visual acuities and refraction were analyzed at the 6-month follow-up visit. RESULTS: The ZZ AR and Phorcides groups comprised 156 and 147 eyes, respectively. At the 6-month postoperative follow-up visit, the median (range) absolute residual cylindrical refraction was 0.35 (1.01) and 0.47 (1.63) diopters (D) for the ZZ AR and Phorcides groups, respectively (P < .001). The percentages of patients with residual cylindrical power within 0.25 D were 29.49% and 13.61% for the ZZ AR and Phorcides groups, respectively (P = .001). Based on the percentages of patients with residual cylindrical powers within 0.50 and 1.00 D, the ZZ AR group showed better outcomes (P = .02 and .01). The percentage of patients with visual acuity better than 20/16 was significantly higher for the ZZ AR group than for the Phorcides group (P = .03). CONCLUSIONS: The fitting-shape-based refractive compensated strategy for topography-guided LASIK procedures can better optimize the visual acuity and astigmatic refraction than the Phorcides software strategy. [J Refract Surg. 2024;40(5):e336-e343.].


Asunto(s)
Topografía de la Córnea , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Cirugía Asistida por Computador , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Agudeza Visual/fisiología , Estudios Prospectivos , Refracción Ocular/fisiología , Adulto , Masculino , Femenino , Láseres de Excímeros/uso terapéutico , Método Doble Ciego , Miopía/cirugía , Miopía/fisiopatología , Adulto Joven , Cirugía Asistida por Computador/métodos , Persona de Mediana Edad , Córnea/cirugía , Córnea/fisiopatología , Estudios de Seguimiento
13.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717083

RESUMEN

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Asunto(s)
Aberrometría , Astigmatismo , Córnea , Sustancia Propia , Aberración de Frente de Onda Corneal , Densitometría , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Queratomileusis por Láser In Situ/métodos , Aberración de Frente de Onda Corneal/fisiopatología , Estudios Prospectivos , Miopía/cirugía , Miopía/fisiopatología , Adulto , Femenino , Masculino , Láseres de Excímeros/uso terapéutico , Agudeza Visual/fisiología , Sustancia Propia/cirugía , Córnea/cirugía , Córnea/fisiopatología , Adulto Joven , Refracción Ocular/fisiología , Astigmatismo/cirugía , Astigmatismo/fisiopatología , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
14.
J Refract Surg ; 40(5): e304-e312, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717085

RESUMEN

PURPOSE: To compare intraoperative performance and early postoperative outcomes following phacoemulsification with two systems using active fluidics and one using gravity-based fluidics. METHODS: In this prospective randomized trial, 200 eyes were randomized to the traditional and Active Sentry groups (n = 80 eyes each) where the Centurion Vision System was used with traditional or Active Sentry (Alcon Laboratories, Inc) hand-pieces, respectively, or the Infinit group (n = 40 eyes) where the Infiniti Vision System (Alcon Laboratories, Inc) was used. Within the traditional and Active Sentry groups, there were two subgroups with low (30 mm Hg) or high (55 mm Hg) intraocular pressure (IOP) used. Outcome measures compared were: cumulative dissipated energy (CDE), percentage change in central corneal thickness (CCT) at 1 day, 1 week, and 1 month, anterior chamber cells at 1 day and 1 week, rate of rise and fall of IOP following occlusion break, corneal endothelial cell density (ECD), and macular thickness 6 months postoperatively. RESULTS: CDE was significantly lower in group II compared to the traditional group (2.96 ± 1.4 vs 4.14 ± 2.2, P = .001). With 30 mm Hg IOP, the Active Sentry group had significantly less percentage change in CCT at 1 week postoperatively compared to the traditional handpiece group (0.01% vs 0.02%, P = .008). Incidence of anterior chamber cells less than grade 2 on day 1 was significantly higher in the Active Sentry group (82.9% vs 52%, P = .03). Percentage change in ECD was significantly lower in the Active Sentry group (-0.957 vs -0.98%, P = .005). Significantly faster rise of IOP to baseline following occlusion break was seen in the Active Sentry group. CONCLUSIONS: The use of Active Sentry handpiece was associated with lower CDE, less postoperative increase in CCT, fewer anterior chamber cells, and faster rise of IOP following occlusion break. [J Refract Surg. 2024;40(5):e304-e312.].


Asunto(s)
Presión Intraocular , Implantación de Lentes Intraoculares , Facoemulsificación , Agudeza Visual , Humanos , Estudios Prospectivos , Presión Intraocular/fisiología , Masculino , Femenino , Anciano , Agudeza Visual/fisiología , Persona de Mediana Edad , Endotelio Corneal/patología , Recuento de Células , Periodo Posoperatorio , Tomografía de Coherencia Óptica , Hidrodinámica , Cámara Anterior , Periodo Intraoperatorio
15.
J Refract Surg ; 40(5): e321-e327, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717082

RESUMEN

PURPOSE: To evaluate the characteristic of corrective epithelial thickness after femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) to correct moderate-to-high hyperopia. METHODS: The prospective case series study of the LIKE procedure was performed to correct moderate-to-high hyperopia. The epithelial thickness map was generated by anterior segment optical coherence tomography (AS-OCT) in the corneal central 9-mm zone. Keratometry and corneal higher order aberrations were analyzed by Pentacam (Oculus Optikgeräte GmbH) preoperatively and postoperatively. RESULTS: In the 26 eyes of 13 participants who underwent the LIKE procedure for moderate-to-high hyperopia, the attempted spherical equivalence (SEQ) was +6.50 ± 1.09 diopters (D). Compared to the preoperative epithelial thickness maps, the postoperative epithelial thickness had become significantly thinner in the central 5-mm zone; the difference was 6 to 7 µm. The paracentral epithelium performed nonuniform remodeling; the thinnest epithelial thickness was located in the inferotemporal section, which has the greatest difference from the superonasal; the difference between these two was approximately 3 µm. Through correlation analysis, it was found that the sections with thinner epithelium were significantly related to corneal curvature and corneal vertical coma. CONCLUSIONS: The LIKE procedure can be used to correct moderate-to-high hyperopia. This study further indicated the epithelial remodeling characteristic after the LIKE procedure: the central and paracentral corneal epithelial thickness becomes thinner, and the epithelial thickness distributes non-uniformly, which may be the important factor of the postoperative curvature asymmetric distribution and induction of corneal vertical coma. [J Refract Surg. 2024;40(5):e321-e327.].


Asunto(s)
Sustancia Propia , Topografía de la Córnea , Epitelio Corneal , Hiperopía , Refracción Ocular , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Hiperopía/cirugía , Hiperopía/fisiopatología , Estudios Prospectivos , Sustancia Propia/cirugía , Sustancia Propia/patología , Masculino , Femenino , Adulto , Agudeza Visual/fisiología , Epitelio Corneal/cirugía , Epitelio Corneal/patología , Refracción Ocular/fisiología , Persona de Mediana Edad , Láseres de Excímeros/uso terapéutico , Adulto Joven , Aberración de Frente de Onda Corneal/fisiopatología , Cirugía Laser de Córnea/métodos , Enfermedades Hereditarias del Ojo
16.
J Refract Surg ; 40(5): e344-e352, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717086

RESUMEN

PURPOSE: To compare the effects of three common refractive surgeries on corneal biomechanics. METHODS: Two hundred seven patients who had refractive surgery were included in this study, of whom 65 received transepithelial photorefractive keratectomy (tPRK), 73 received femtosecond laser-assisted laser in situ keratomileusis (FSLASIK), and 69 received small incision lenticule extraction (SMILE). Each patient had biomechanical measurements using the Corvis ST (Oculus Optikgeräte GmbH) preoperatively and at 3 and 6 months postoperatively. The measurements included five parameters expected to be associated with corneal biomechanics: deformation amplitude ratio at 2 mm (DAR2), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), highest concavity time (HCT), and the updated stress-strain index (SSIv2). The variations in these parameters postoperatively among the three surgeries, and their relationship with corneal thickness (CCT) and intraocular pressure measured by the Dynamic Contour Tonometer (DCT-IOP) were analyzed. RESULTS: SP-A1 decreased significantly from preoperatively to 3 months postoperatively in all three groups, whereas DAR2 and IIR increased significantly, all indicating stiffness losses. Between 3 and 6 months postoperatively, the results were inconsistent, with DAR2 decreasing (indicating stiffness increases) and IIR increasing (denoting stiffness decreases) in the FS-LASIK and SMILE groups. The decrease in SSIv2 (the only measure of corneal material stiffness) postoperatively was comparatively less pronounced at both 3 and 6 months postoperatively. On the other hand, HCT remained generally stable after all three surgeries. Unlike DAR2, IIR, and SP-A1, the changes postoperatively in stiffness parameters HCT and SSIv2 were independent of the corresponding changes in both DCT-IOP and CCT. CONCLUSIONS: Among the stiffness parameters considered, SSIv2 was not correlated with CCT or DCT-IOP, and holds promise for representing the corneal material stiffness and how it remains largely unaffected by refractive surgeries. Overall, FS-LASIK had the most significant impact on corneal stiffness, followed by SMILE, and finally tPRK. [J Refract Surg. 2024;40(5):e344-e352.].


Asunto(s)
Córnea , Elasticidad , Presión Intraocular , Queratomileusis por Láser In Situ , Láseres de Excímeros , Miopía , Humanos , Córnea/fisiopatología , Córnea/cirugía , Adulto , Femenino , Masculino , Fenómenos Biomecánicos , Láseres de Excímeros/uso terapéutico , Queratomileusis por Láser In Situ/métodos , Adulto Joven , Elasticidad/fisiología , Miopía/cirugía , Miopía/fisiopatología , Presión Intraocular/fisiología , Queratectomía Fotorrefractiva/métodos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Persona de Mediana Edad , Estudios Prospectivos , Cirugía Laser de Córnea/métodos , Topografía de la Córnea
17.
Eur J Ophthalmol ; 34(3): NP97-NP100, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38699790

RESUMEN

INTRODUCTION: We present a single-eyed case with a previous diagnosis of breast cancer who had intraretinal cystoid changes associated with the systemic administration of ixabepilone in her only seeing eye. To our best knowledge, this is the first reported case describing this phenomenon related to the ixabepilone administration. CASE DESCRIPTION: A 54-year-old woman with a history of breast cancer was examined due to visual deterioration in her only good left eye. The patient had undergone cataract surgery and lens implantation in her right eye following a childhood accident, but subsequently had developed a refractory glaucoma and lost her right vision. Six cycles of 40 mg/m2 systemic ixabepilone (3-hly intravenous infusion once every 3 weeks) had been administered within the past six months. Her visual decline started two weeks following the last treatment session. She was offered intravitreal anti-vascular endothelial growth factor injection elsewhere. Fluorescein angiogram showed no dye leakage whereas spectral-domain optical coherence tomography demonstrated parafoveal intraretinal cystoid changes. En-face optical coherence tomography revealed petaloid type roundish hyporeflective areas at the level of superficial and deep vascular plexus. Ixabepilone-associated cystoid maculopathy was suspected as she received only ixabepilone for the chemotherapy in the last six months. We thus recommended her not to continue ixabepilone therapy. Ten weeks after the ixabepilone cessation, intraretinal cystoid changes had resolved completely. CONCLUSION: Angiographically silent intraretinal cystoid changes may develop in association with the use of ixabepilone. Referral to an ophthalmologist should be considered for the patients experiencing visual complaints as ixabepilone cessation may lead to visual improvement and avoid unnecessary treatment.


Asunto(s)
Neoplasias de la Mama , Epotilonas , Angiografía con Fluoresceína , Edema Macular , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Femenino , Persona de Mediana Edad , Edema Macular/tratamiento farmacológico , Edema Macular/diagnóstico , Epotilonas/efectos adversos , Epotilonas/administración & dosificación , Agudeza Visual/fisiología , Neoplasias de la Mama/tratamiento farmacológico , Fondo de Ojo
18.
Invest Ophthalmol Vis Sci ; 65(5): 17, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38717424

RESUMEN

Purpose: We aimed to identify structural differences in normal eyes, early age-related macular degeneration (AMD), and intermediate AMD eyes using optical coherence tomography (OCT) in a well-characterized, large cross-sectional cohort. Methods: Subjects ≥ 60 years with healthy normal eyes, as well as early or intermediate AMD were enrolled in the Alabama Study on Age-related Macular Degeneration 2 (ALSTAR2; NCT04112667). Using Spectralis HRA + OCT2, we obtained macular volumes for each participant. An auto-segmentation software was used to segment six layers and sublayers: photoreceptor inner and outer segments, subretinal drusenoid deposits (SDDs), retinal pigment epithelium + basal lamina (RPE + BL), drusen, and choroid. After manually refining the segmentations of all B-scans, mean thicknesses in whole, central, inner and outer rings of the ETDRS grid were calculated and compared among groups. Results: This study involved 502 patients, 252 were healthy, 147 had early AMD, and 103 had intermediate AMD eyes (per Age-Related Eye Disease Study [AREDS] 9-step). Intermediate AMD eyes exhibited thicker SDD and drusen, thinner photoreceptor inner segments, and RPE compared to healthy and early AMD eyes. They also had thicker photoreceptor outer segments than early AMD eyes. Early AMD eyes had thinner photoreceptor outer segments than normal eyes but a thicker choroid than intermediate AMD eyes. Using the Beckman scale, 42% of the eyes initially classified as early AMD shifted to intermediate AMD, making thickness differences for photoreceptor outer segments and choroid insignificant. Conclusions: With AMD stages, the most consistent structural differences involve appearance of drusen and SDD, followed by RPE + BL thickness, and then thickness of photoreceptor inner and outer segments. Structural changes in the transition from aging to intermediate AMD include alterations in the outer retinal bands, including the appearance of deposits on either side of the RPE.


Asunto(s)
Coroides , Degeneración Macular , Drusas Retinianas , Epitelio Pigmentado de la Retina , Tomografía de Coherencia Óptica , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Coroides/patología , Coroides/diagnóstico por imagen , Estudios Transversales , Degeneración Macular/diagnóstico , Drusas Retinianas/diagnóstico , Segmento Externo de las Células Fotorreceptoras Retinianas/patología , Epitelio Pigmentado de la Retina/patología , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Agudeza Visual/fisiología
19.
PLoS One ; 19(5): e0303400, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739635

RESUMEN

Visual abilities tend to vary predictably across the visual field-for simple low-level stimuli, visibility is better along the horizontal vs. vertical meridian and in the lower vs. upper visual field. In contrast, face perception abilities have been reported to show either distinct or entirely idiosyncratic patterns of variation in peripheral vision, suggesting a dissociation between the spatial properties of low- and higher-level vision. To assess this link more clearly, we extended methods used in low-level vision to develop an acuity test for face perception, measuring the smallest size at which facial gender can be reliably judged in peripheral vision. In 3 experiments, we show the characteristic inversion effect, with better acuity for upright faces than inverted, demonstrating the engagement of high-level face-selective processes in peripheral vision. We also observe a clear advantage for gender acuity on the horizontal vs. vertical meridian and a smaller-but-consistent lower- vs. upper-field advantage. These visual field variations match those of low-level vision, indicating that higher-level face processing abilities either inherit or actively maintain the characteristic patterns of spatial selectivity found in early vision. The commonality of these spatial variations throughout the visual hierarchy means that the location of faces in our visual field systematically influences our perception of them.


Asunto(s)
Reconocimiento Facial , Campos Visuales , Humanos , Campos Visuales/fisiología , Femenino , Masculino , Adulto , Reconocimiento Facial/fisiología , Adulto Joven , Estimulación Luminosa , Percepción Visual/fisiología , Agudeza Visual/fisiología , Cara/fisiología
20.
Transl Vis Sci Technol ; 13(5): 12, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38758570

RESUMEN

Purpose: To evaluate the visual performance in adolescents undergoing orthokeratology (OrthoK) treatment with two different optical zone diameters (OZDs). Methods: This randomized, double-masked, self-controlled prospective study was conducted at Tianjin Eye Hospital (Tianjin, China) in June 2022. Thirty-six eligible schoolchildren were enrolled and fitted with corneal refractive therapy lenses with two sizes of OZDs (5 mm [5OZ] and 6 mm [6OZ]). Each participant was randomized to wear the 5OZ in one eye and the 6OZ in the contralateral eye. Subjective visual quality was assessed using visual acuity, refraction, contrast sensitivity function, and visual symptoms, and the objective optical quality was assessed using ocular higher order aberrations (HOAs) and modulation transfer function (MTF). Results: Thirty-five myopic children completed a 1-month follow-up visit. The 5OZ lens induced significantly smaller treatment zone diameters than the 6OZ lens (P < 0.001). Subjective visual quality did not differ significantly between the two groups. Compared to baseline, aberrations of Z40, coma-like, spherical-like, and total HOAs in both groups increased significantly (P < 0.05). For the 3-mm pupils, spherical aberration in the 5OZ group was significantly higher than that in the 6OZ group (P < 0.05). The MTF value of the 6OZ group was significantly higher than that of 5OZ group for 0.3 and 1.5 cycles per degree for the 3-mm pupils (P = 0.006 and P = 0.026, respectively). However, HOAs or MTF did not differ significantly between the two groups for the 5-mm pupils. Conclusions: The difference induced by varying OZD was significant only in the smaller pupil condition. The selection of OZD in OrthoK designs in real-world patient management should be done while considering individual pupil size. Translational Relevance: This study revealed that the objective visual quality of small OZD lenses was only slightly affected for the small pupil size.


Asunto(s)
Miopía , Procedimientos de Ortoqueratología , Refracción Ocular , Agudeza Visual , Humanos , Femenino , Procedimientos de Ortoqueratología/métodos , Masculino , Agudeza Visual/fisiología , Estudios Prospectivos , Adolescente , Miopía/terapia , Miopía/fisiopatología , Niño , Método Doble Ciego , Refracción Ocular/fisiología , Sensibilidad de Contraste , Lentes de Contacto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...