Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
São Jose dos Campos; s.n; 2021. 89 p. il., graf., tab..
Tesis en Portugués | BBO - Odontología | ID: biblio-1254630

RESUMEN

Este trabalho teve como objetivo investigar a rugosidade, o desgaste e o brilho superficial de uma resina composta nanoparticulada (Filtek Z350 XT - 3M ESPE), com diferentes sistemas de polimento a seco e lubrificado antes e após envelhecimento artificial. Foram confeccionados 100 espécimes de resina composta em forma de disco, divididos em: grupo controle (sem polimento) e em três sistemas de polimento (pontas de diamante de etapa única Dimanto - VOCO, discos de lixa Sof-Lex Pop-On - 3M ESPE - e escova de polimento com carbeto de silício nas cerdas Astrobrush - IVOCLAR VIVADENT). Os sistemas polidores foram empregados sem lubrificação, com água e com vaselina. Após a fase de envelhecimento por escovação, foi realizado o repolimento das amostras, exceto no grupo controle. Ao final de cada tempo do estudo (inicial, polimento, envelhecimento e repolimento), os grupos foram submetidos as leituras de rugosidade, desgaste e brilho, verificando assim a efetividade de cada sistema de polimento. Os dados referentes a cada avaliação quantitativa foram submetidos à análise estatística de variância de medidas repetidas. As comparações múltiplas foram realizadas por teste Pos-hoc de Tukey. Diferenças significantes foram determinadas por p < 0,05. Para as análises de brilho e rugosidade póspolimento o Dimanto não foi influenciado pelo uso ou não de lubrificantes. O Sof-Lex Pop-On obteve melhor desempenho sem utilização de lubrificante, enquanto a escova Astrobrush apresentou maiores valores de brilho e menor rugosidade quando lubrificada por água ou vaselina. Em relação ao desgaste superficial, o Dimanto foi melhor, quando associado a vaselina. O Sof-Lex PopOn apresentou menor desgaste, quando utilizado com água. A escova Astrobrush obteve o pior resultado quando lubrificada com vaselina. Portanto, o brilho, a rugosidade e o desgaste superficial dependem do polidor e da combinação com ou sem lubrificação(AU)


The aim of this study was to investigate the roughness, wear and surface gloss of a nanoparticulated resin composite (Filtek Z350 XT - 3M ESPE), with dry and lubricated polishing systems before and after artificial aging. One hundred resin composite specimens were fabricated in cylindrical shape, which was further divided into: control group (no polishing) and three polishing systems (One step diamond tips Dimanto -VOCO, Sof-Lex Pop-On -3M ESPE, and a silicon carbide polishing brush - Astrobrush -IVOCLAR VIVADENT). Polishing systems was used dry, with water or petroleum jelly. After aging by simulated tooth brushing, the samples' repolishing was carried out, except in the control group. After each study period (initial, polishing, aging and repolishing), the groups were subjected to roughness, wear and gloss, thus verifying the effectiveness of each polishing system. The data for each quantitative evaluation was submitted to repeated-measures analysis of variance. Multiple comparisons were performed by Tukey post-hoc test. Significant differences were determined by p <0.05. For post-polishing gloss and roughness analyzes, Dimanto was not influenced by the use or not of lubricants. Sof-Lex Pop-On achieved better performance without using lubricant, while the Astrobrush brush showed higher values of gloss and less roughness when lubricated by water or petroleum jelly. Regarding surface wear, Dimanto was better when associated with petroleum jelly. Sof-Lex Pop-On showed less wear when used with water. The Astrobrush brush obtained the worst result when lubricated with petroleum jelly. The brightness, roughness and surface wear depend on the polisher and the combination with or without lubrication(AU).


Asunto(s)
Pulido Dental/efectos adversos , Envejecimiento/efectos de los fármacos , Resinas Compuestas/administración & dosificación , Alisadura de la Restauración Dental/efectos adversos , Fenómenos Ópticos
2.
São José dos Campos; s.n; 2020. 83 p. il., graf., tab..
Tesis en Portugués | BBO - Odontología, LILACS | ID: biblio-1248193

RESUMEN

O objetivo do estudo foi avaliar o comportamento mecânico de materiais restauradores utilizados na reabilitação da guia canino. O estudo foi dividido em uma etapa in sílico e outra in vitro. Dez modelos 3D de dentes caninos hígidos foram obtidos por engenharia reversa e utilizados como Grupo Controle (n = 10) para o teste in sílico por meio da análise por elementos finitos (FEA). Um desgaste incisal de 2 mm foi simulado em cada amostra 3D e reabilitado com restauração incisal direta de resina composta (Grupo IRC, n = 10) e indireta de cerâmica (Grupo IC, n = 10). Os mesmos modelos também receberam, além do desgaste incisal, um preparo vestibular para faceta laminada, restaurados com os mesmos materiais, compondo os Grupos FRC (faceta de resina composta, n = 10) e FC (faceta cerâmica, n = 10). Os modelos foram exportados para um software de engenharia assistida por computador (CAE) e as geometrias foram transformadas em malhas de elementos tetraédricos, consideradas sólidas, isotrópicas, homogêneas e lineares. Uma carga de 100 N foi aplicada simulando a desoclusão pelo canino para análise mecânica estrutural dinâmica. A deformação total foi mensurada e a tensão máxima principal foi usada como critério de falha. Com base nos resultados da avaliação in sílico, dois tipos de restauração foram selecionados para a fase in vitro, onde realizou-se um ensaio mecânico de fadiga para análise do desgaste. Trinta dentes caninos hígidos foram distribuídos em três grupos: Controle (n = 10), IRC (n = 10) e FC (n = 10). As amostras foram submetidas ao ensaio de fadiga em cicladora mecânica com deslizamento de 2 mm por 240.000 ciclos, carga de 49 N e 4 Hz de frequência, imersas em água em temperatura ambiente. A cada 60.000 ciclos as amostras foram moldadas e seus modelos escaneados para avaliação da quantidade de desgaste através da técnica de correlação por imagem digital, quantificando a perda de estrutura a cada intervalo. As técnicas restauradoras com resina composta sofreram maior deformação total, tendo a cerâmica um comportamento semelhante ao dente hígido. A probabilidade de falha no movimento de desoclusão foi menor na cerâmica. Para o desgaste, não houve diferença significante entre grupos experimentais até 180.000 ciclos. Aos 240.000 ciclos, a resina composta apresentou maior desgaste que a cerâmica (p = 0,02). Todos os grupos provocaram desgaste em seus antagonistas, mas não houve diferença significante entre eles (p < 0,05). Dentro das limitações deste estudo, pode-se concluir que os laminados cerâmicos apresentaram menor desgaste, deformação e probabilidade de falha na restauração da guia canino. Ainda, a anatomia do dente e o tipo de restauração influenciaram o comportamento dos materiais(AU)


The purpose of this study was to evaluate the mechanical behavior of materials restorative used in rehabilitation of canine guide. The study was divided in two parts in silico and in vitro test. Ten 3D models of sound canine teeth were obtained by reverse engineering technique and used as Control Group (n = 10) to in silico test by finite elements analysis (FEA). A 2 mm wear were simulated in each 3D sample and restored according to restorative material; Group IRC (Incisal Composite Resin, n=10) and Group IC (Incisal Ceramic, n = 10). Laminate preparations were modeled and restored with the same materials, Group FRC (Laminate Composite Resin, n=10) and Group FC (Laminate Ceramic, n = 10). All models were exported to Computer Aided Engineering (CAE) software, the geometries were meshed with tetrahydric elements and all contacts were considered perfectly bonded. The load simulated the canine guide (100 N) and the assembly was constrained at the bottom surface to run a structural mechanic dynamic analysis. The Total Deformation was measured and Maximum Principal Stress was used as failure criteria. Thirty sound canine tooth were divided in three groups to in vitro test; Control (n = 10), IRC (n = 10) and FC (n = 10). The samples were subjected to the fatigue test in a wear machine for 240.000 cycles, load of 49 N, frequency of 4 Hz, sliding distance of 2 mm in water at room temperature. The samples were molded every 60.000 cycles and their models scanned to evaluate wear by digital image correlation. Composite resin groups showed higher total deformation and ceramic groups had a more similar behavior to the control group. The probability of failure was lower for the ceramic in the canine guidance. For wear, there was no significant difference between groups up to 180.000 cycles. After 240.000 cycles, the wear was greater in the IRC group (p = 0,02). The wear of the antagonists was not statistically different between groups. Within the limitations of this study, it can be concluded that the ceramic laminates showed less wear, deformation and probability of failure in restoring of the canine guide. In addition, anatomy of the tooth and type of restoration influenced the behavior of the materials(AU)


Asunto(s)
Desgaste de los Dientes/complicaciones , Alisadura de la Restauración Dental/efectos adversos , Análisis de Elementos Finitos/estadística & datos numéricos , Restauración Dental Permanente/métodos
3.
São José dos Campos; s.n; 2020. 105 p. il., graf., tab..
Tesis en Portugués | BBO - Odontología | ID: biblio-1150839

RESUMEN

O presente estudo teve por objetivo avaliar o comportamento da camada de caracterização sobre zircônia de alta translucidez (YZHT, Vita YZ HT), cerâmica feldspática (FD/VMII, Vita Mark II) e silicato de lítio reforçado por zircônia (ZLS, Vita Suprinity) frente à simulação de desgaste fisiológico variando os antagonistas em YZHT, esteatita e cerâmica híbrida com polímero (Vita Enamic). Foram obtidos 120 discos (ø 12 mm, 1,2 mm de espessura) cerâmicos, sendo 30 de YZHT e FD, e 60 de ZLS, através de corte de blocos para CAD/CAM. As amostras de YZHT foram sinterizadas, e na sequência os grupos YZHT e FD receberam a camada de caracterização. A caracterização das amostras de ZLS foi realizada no mesmo ato da cristalização (ZLS1, etapa única) ou em queima posterior a cristalização (ZLS2, duas etapas). A caracterização foi realizada de acordo com as recomendações do fabricante e todas as amostras receberam aplicação de glaze e consequente queima. Os espécimes foram divididos em subgrupos (n=10) de acordo com os antagonistas: esteatita, cerâmica híbrida ou zircônia; em seguida, foram submetidos à simulação do desgaste fisiológico. Os parâmetros de rugosidade média (Ra) e largura média dos elementos do perfil de rugosidade (Rsm) foram analisados em diferentes momentos da simulação de desgaste fisiológico desde o início até o final da ciclagem. Após os 15.000 ciclos foram calculados a perda de massa dos discos cerâmicos e dos pistões antagonistas. Os resultados foram analisados estatisticamente por Anova 2 fatores e Tukey (p<0,05). Antes do desgaste, as cerâmicas não apresentaram diferenças para os parâmetros de rugosidade, Ra (p=0,3348), Rz (p=0,5590) e Rsm (p=0,5330). Os antagonistas não apresentaram diferenças para os parâmetros, Ra (p=0,0541) e Rsm (p=0,0613), enquanto que o parâmetro Rz (p=0,000) apresentou diferença, já que a esteatita (18,98 ± 2,98 µm) apresentou uma maior rugosidade média quando analisada a altura máxima do perfil quando comparado com os antagonistas em enamic (12,35 ± 0,91 µm) e zircônia (11,47 ± 0,89 µm). Após o desgaste, as cerâmicas continuaram sem apresentar diferenças estatísticas para os parâmetros de rugosidade, Ra (p=0,488), Rz (p=0,681) e Rsm (p=0,256). Os antagonistas não apresentaram diferença para o parâmetro Ra (p=0,124), porém, apresentaram diferença para o parâmetro Rz (p=0,000), já que a esteatita (57,98 ± 4,11 µm) apresentou uma maior média para tal parâmetro quando comparado com os antagonistas em enamic (44,86 ± 2,34 µm) e zircônia (37,81 ± 1,40 µm); e para o parâmetro Rsm (p=0,000), já que as médias da esteatita (502,72 ± 72,20 µm), enamic (385,67 ± 24,84 µm) e zircônia (268,94 ± 27,99 µm) apresentaram diferenças entre si. O tipo de cerâmica (p<0,0001) influenciou a perda de massa das amostras e a interação entre cerâmica e antagonista (p=0,0098), com isso influenciou a perda de massa dos pistões antagonistas. O grupo ZLS 2 apresentou a maior perda de massa entre os grupos testados. Todos os antagonistas testados apresentaram perda de massa semelhante contra o FD, enquanto a esteatita apresentou maior perda de massa quando testadas com amostras YHZT, ZLS 1 e ZLS 2. Todas as cerâmicas apresentaram rugosidade semelhante antes e após a simulação de desgaste. As amostras de cerâmicas apresentaram uma perda de massa semelhante. No entanto, a queima adicional da caracterização da cerâmica de silicato de lítio reforçado por zircônia favoreceu uma maior perda de massa, sem que houvesse alteração de sua resistência(AU)


The present study aimed to evaluate the behavior of the characterization layer on high translucency zirconia (YZHT, Vita YZ HT), feldspar ceramic (FD / VMII, Vita Mark II) and zirconia reinforced lithium silicate (ZLS, Vita Suprinity) compared to the simulation of physiological wear, varying the antagonists in YZHT, steatite and hybrid ceramic with polymer (Vita Enamic). 120 ceramic discs (ø 12 mm, 1.2 mm thick) were obtained, 30 from YZHT and FD, and 60 from ZLS, by cutting blocks for CAD / CAM. The YZHT samples were sintered, and in the sequence the groups YZHT and FD received the characterization layer. The characterization of the ZLS samples was carried out in the same act of crystallization (ZLS1, single step) or in burning after crystallization (ZLS2, two steps). The characterization was carried out according to the manufacturer's recommendations and all samples received application of glaze and consequent burning. The specimens were divided into subgroups (n = 10) according to the antagonists: steatite, hybrid ceramic or zirconia; then, they were submitted to the simulation of physiological wear. The parameters of average roughness (Ra) and average width of the elements of the roughness profile (Rsm) were analyzed at different moments of the simulation of physiological wear from the beginning to the end of the cycle. After 15,000 cycles, the mass loss of the ceramic discs and antagonistic pistons was calculated. The results were analyzed statistically by Anova 2 factors and Tukey (p <0.05). Before wear, the ceramics showed no differences for the roughness parameters, Ra (p = 0.3348), Rz (p = 0.5590) and Rsm (p = 0.5330). The antagonists showed no differences for the parameters, Ra (p = 0.0541) and Rsm (p = 0.0613), while the parameter Rz (p = 0.000) showed a difference, since steatite (18.98 ± 2) , 98 µm) presented a higher average roughness when the maximum profile height was analyzed when compared with the antagonists in enamic (12.35 ± 0.91 µm) and zirconia (11.47 ± 0.89 µm). After wear, the ceramics continued to show no statistical differences for the roughness parameters, Ra (p = 0.488), Rz (p = 0.681) and Rsm (p = 0.256). The antagonists showed no difference for the Ra parameter (p = 0.124), however, they showed a difference for the Rz parameter (p = 0.000), since steatite (57.98 ± 4.11 µm) showed a higher average for such parameter when compared with antagonists in enamic (44.86 ± 2.34 µm) and zirconia (37.81 ± 1.40 µm); and for the parameter Rsm (p = 0.000), since the averages of steatite (502.72 ± 72.20 µm), enamic (385.67 ± 24.84 µm) and zirconia (268.94 ± 27.99 µm ) showed differences between them. The type of ceramic (p <0.0001) influenced the loss of mass of the samples and the interaction between ceramic and antagonist (p = 0.0098), thereby influencing the loss of mass of the antagonist pistons. The ZLS 2 group showed the greatest loss of mass among the tested groups. All tested antagonists showed similar mass loss against FD, while steatite showed greater mass loss when tested with YHZT, ZLS 1 and ZLS 2 samples. All ceramics showed similar roughness before and after wear simulation. The ceramic samples showed a similar mass loss. However, the additional burning of the characterization of the zirconia-reinforced lithium silicate ceramic favored a greater loss of mass, without altering its strength(AU)


Asunto(s)
Cerámica/análisis , Alisadura de la Restauración Dental/efectos adversos , Materiales Dentales/síntesis química
4.
São José dos Campos; s.n; 2020. 51 p. il., graf., tab..
Tesis en Portugués | BBO - Odontología | ID: biblio-1151428

RESUMEN

Este estudo avaliou a resistência ao desgaste fisiológico da camada de caracterização aplicada sobre cerâmica híbrida com diferentes tratamentos de superfície, em função do antagonista. Foram confeccionados 160 discos (12 mm de diâmetro, 1,2 mm de espessura) de cerâmica híbrida com polímero (Vita Enamic, Vita Zhanfabrick, Bad Säckingen, Alemanha) e foram polidos com lixas de carbeto de silício até # 1200 e divididas aleatoriamente em grupos experimentais (n = 10), de acordo com o tratamento da superfície da cerâmica previamente à caracterização e a finalização da cerâmica com camada de glaze ou não (P: amostras polidas sem caracterização; PG: amostras polidas, finalização com glaze; C: pigmentação convencional; CG: pigmentação convencional, finalização com glaze; J: jateamento; JG: jateamento, finalização com glaze; S: uso de silano autocondicionante; SG: uso de silano autocondicionante, finalização com glaze). Metade dos espécimes foram submetidos à simulação do desgaste fisiológico com aplicadores de esteatita, enquanto para a outra metade com aplicadores de cerâmica híbrida. Com auxílio de perfilômetro de contato foram analisados parâmetros de rugosidade. A rugosidade média Ra e espaçamento RSm foram analisados pela estatística ANOVA 3 fatores (tratamento de superfície x presença de glaze x antagonista), seguido por teste de Tukey com a=5%. Houve influência da interação dos 3 fatores na rugosidade média (Ra) da cerâmica PIC (p=0,000) e na interação 2 fatores (tratamento de superfície x presença glaze) na rugosidade de espaçamento RSm da cerâmica PIC (p=0,011). A cerâmica híbrida necessita de um tratamento de superfície para que seja realizada a caracterização extrínseca. A aplicação do glaze após a caracterização reduz a rugosidade superficial e o potencial de desgaste do antagonista(AU)


This study evaluated the resistance to physiological wear of the characterization layer applied over hybrid ceramic with different surface treatments, with different antagonists. One hundred and sixty discs were confectioned (12 mm of diameter, 1.2 mm of thickness) of hybrid ceramic with polymer (Vita Enamic, Vita Zhanfabrick, Bad Säckingen, Germany) and were polished with silicon carbide paper # 1200 and randomly divided into experimental groups (n = 10), according to the surface treatment previously to the characterization and finishing of the ceramic either with a glaze layer or not (P: samples polished without characterization; PG: polished samples with glaze finishing; C: conventional pigmentation; CG: conventional pigmentation finishing with glaze; J: sandblasting; JG: sandblasting, finishing with glaze; S: use of self-etching silane; SG: use of self-etching silane, finishing with glaze). Half of the specimens were submitted to simulation of physiological wear with steatite applicators, meanwhile for the other half, applicators of hybrid ceramic were used. With the aid of a contact perfilometer, roughness parameters were analyzed. The mean roughness Ra and spacing roughness RSm were statistically analyzed by 3-way ANOVA (surface treatment x glaze presence x antagonist), followed by Tukey (a= 5%). There was influence of interaction of the three factors in mean roughness (Ra) of hybrid ceramic (p=0.000) and in the interaction of two factors (surface treatment x glaze presence) in the spacing roughness RSm of the hybrid ceramic (p=0.011). Hybrid ceramic require a surface treatment for extrinsic characterization. Glaze application after characterization decreases surface roughness and wear potential of the antagonist(AU)


Asunto(s)
Cerámica/síntesis química , Alisadura de la Restauración Dental/efectos adversos , Materiales Dentales/provisión & distribución
5.
Biomed Mater Eng ; 30(4): 365-374, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31476141

RESUMEN

BACKGROUND: Ceramic crown that fires the layering porcelain on zirconia corping is starting to be used due to aesthetic requirements. However, many ceramics are used, but wear characteristics are often unknown. OBJECTIVE: This study was performed to investigate the wear of human enamel by porcelains, and to determine the influence of porcelain hardness, surface roughness and crystal of porcelain on the enamel wear. METHODS: Enamel specimens were prepared from extracted human molar teeth. Porcelain specimens were prepared from Deguceram Gold, Vita Omega 900, and Cercon Ceram Kiss. Enamel wear volume was calculated and the porcelain wear depth, surface roughness and Vickers hardness was measured. Moreover, the observation of a crystal by scanning electron microscope and the crystal by X-ray diffraction were identified. RESULTS: Omega 900 showed the smallest enamel wear volume and porcelain wear depth. The Vickers hardnesses of Omega 900 and Cercon Ceram Kiss were almost identical. Leucite was detected from Deguceram Gold and Omega 900, and Silica and Silicon Nitride were detected from Cercon Ceram Kiss. CONCLUSIONS: The enamel wear is influenced not by the hardness of the porcelain but by the surface roughness, the size and shape of the crystal.


Asunto(s)
Coronas , Esmalte Dental/anatomía & histología , Porcelana Dental/química , Coronas/efectos adversos , Cristalización , Esmalte Dental/química , Porcelana Dental/efectos adversos , Alisadura de la Restauración Dental/efectos adversos , Dureza , Humanos , Ensayo de Materiales , Propiedades de Superficie , Difracción de Rayos X
6.
São José dos Campos; s.n; 2019. 88 p. il., tab., graf..
Tesis en Portugués | LILACS, BBO - Odontología | ID: biblio-1017252

RESUMEN

A recessão gengival está frequentemente associada à lesão cervical não-cariosa. Quando as duas lesões estão associadas, dão origem a uma lesão combinada (LC) que tem um prognóstico de tratamento diferente de quando as duas lesões se apresentam sozinhas. A literatura apresenta alguns estudos que avaliaram uma abordagem multidisciplinar para otimizar o tratamento dessa LC. No entanto, as abordagens propostas possuem limitações de técnicas e materiais, sem um protocolo clínico ideal estabelecido. Dessa forma, o objetivo do presente estudo foi avaliar um novo protocolo multidisciplinar, com duas resinas compostas e dois sistemas adesivos distintos através de estudo clínico randomizado. Foram selecionadas 80 lesões combinadas, alocadas aleatoriamente em um dos seguintes grupos: AC+NP (n=20) - restauração parcial da lesão cervical com resina nanoparticulada e sistema adesivo de condicionamento total em 2 passos e cirurgia para recobrimento radicular, AU+NP (n=20) - restauração parcial da lesão cervical com resina nanoparticulada e sistema adesivo autocondicionante e cirurgia para recobrimento radicular, AC+MH (n=20) - restauração parcial da lesão cervical com resina microhíbrida e sistema adesivo de condicionamento total em 2 passos e cirurgia para recobrimento radicular, AU+MH (n=20) - restauração parcial da lesão cervical com resina microhíbrida e sistema adesivo autocondicionante e cirurgia para recobrimento radicular. Foram realizadas avaliações das restaurações pelo método USPHS após 1 semana, 6 meses e 12 meses. A análise de sobrevivência das restaurações foi realizada através do teste de Kaplan-Meier. Os protocolos restauradores foram comparados para cada parâmetro pelo teste exato de Fisher, considerando tipo de adesivo e tipo de resina empregados. Teste de Qui-Quadrado foi utilizado para comparação das taxas após 6 e 12 meses entre os grupos testados. A avaliação da normalidade foi realizada pelo teste de Shapiro-Wilks. As medidas clínicas de RGR, PS, NIC, ETQ, ATQ, Hipersensibilidade Dentinária e Estética (VAS) foram comparadas tanto intra como intergrupo por teste de variância de medidas repetidas ANOVA de dois fatores e Tukey com teste post-hoc. IP, IS foram avaliados pelo teste de Qui-Quadrado. Os parâmetros de DC, Porcentagem de recobrimento e RecRed foram analisados pelo ANOVA 1 fator. Pôde-se observar uma taxa de sucesso geral cumulativo do tratamento de 98,7% aos 6 primeiros meses e 92,4% aos 12 meses de acompanhamento, sem diferença estatisticamente significativa entre os tempos e grupos avaliados. Todos os grupos apresentaram melhora estética e redução de hipersensibilidade significativa em relação ao baseline (p<0,001) após 6 meses. Houve redução significativa da recessão gengival relativa (p<0,05) após 12 meses de acompanhamento. Dentro dos limites do presente estudo, pode-se concluir que os materiais utilizados apresentaram desempenho clínico similares, sendo que as diferentes combinações de materiais restauradores adesivos estudados associados às técnicas cirúrgicas utilizadas podem ser empregadas no tratamento das lesões cervicais não-cariosas associadas a recessão gengival(AU)


Non-carious cervical lesion is frequently associated with gingival recession, resulting in a combined lesion (CL) that has a different treatment prognosis when the two lesions appear alone. The literature presents few studies that evaluate a multidisciplinary approach to optimize the treatment of this CL. The previously proposed approaches and materials have limitations and an optimal clinical protocol has not been established yet. Thus, the aim of this study was to evaluate a novel multidisciplinary protocol with two resin composites and two different adhesive systems by a randomized clinical. Eighty combined lesions were randomly assigned to one of the following groups: NP + TE (n = 20) - partial restoration of cervical lesions with nanofilled composite and total-etch adhesive system and periodontal surgery for root coverage, NP + UA (n =20) - partial restoration of cervical lesions with nanofilled composite and self-etching adhesive system and periodontal surgery for root coverage, MH + TE (n = 20) - partial restoration of cervical lesions with microhybrid composite and total-etch adhesive system and periodontal surgery for root coverage, MH + UA (n = 20) - partial restoration of cervical lesions with microhybrid composite and selfetching adhesive system and periodontal surgery for root coverage. Restorations were assessed using the USPHS criteria after one week, six months and twelve months. Survival rate was assessed by Kaplan-Meier test. Restorative protocols were compared for each parameter by Fisher's exact test, considering type of adhesive and type of composite used. Chi-square test was used to compare the rates at 6 and 12 months between the groups tested. Normality evaluation was assessed by Shapiro-Wilks test. Clinical measures of RGR, PS, NIC, KTW, KTH, Hipersensitivity and Esthetics (VAS) were compared both intra and inter-group by analysis of variance of repeated measures Two-Way ANOVA and Tukey posthoc test. IP, IS were evaluated by Chi-square test. CD parameter, Coverage percentage and RecRed were evaluated by One-Way ANOVA. It was observed a successful cumulative rate of 98.7 % at 6 months and 92.4 % at 12 months with no significant difference between groups. When compared to baseline, all groups presented significant improvement in esthetics and reduction of hipersensitivity at 6 months (p<0.001). Significant reduction of gingival recession was recorded after 12 months (p<0.05). It can be concluded that there is no difference between the tested materials, and different combinations of adhesive restorative materials associated with periodontal surgical techniques can be used to treat non-carious cervical lesions associated with gingival recession(AU)


Asunto(s)
Humanos , Recesión Gingival/diagnóstico , Resinas Compuestas/administración & dosificación , Alisadura de la Restauración Dental/efectos adversos , Desgaste de los Dientes/complicaciones
7.
Acta odontol. latinoam ; 29(1): 7-13, 2016. tab, graf, ilus
Artículo en Inglés | LILACS | ID: lil-790201

RESUMEN

The aim of this study was to evaluate the shear bond strengthof resin composite repairs with and without aging of thesurface to be repaired, using different adhesive systems andresin composites. Ninety specimens were prepared: 10 for theControl Group (GC - without repair); 40 for Group I (GI -repairs after 7 days) and 40 for Group II (GII - repairs after180 days). Groups I and II were divided into 4 subgroups of10 specimens each, according to the adhesive system andcomposite resin used: A) Adper Scotch Bond Multipurpose +Filtek Z350 XT; B) Adper Single Bond Plus + Filtek Z350 XT;C) Adper Scotch Bond Multipurpose + Esthet-X; D) AdperSingle Bond Plus + Esthet-X. The specimens were tested forshear strength in a universal testing machine. The resultswere analyzed by two-factor one-way ANOVA and Fisher’spost hoc tests (alpha=0.05). The control group had betterperformance than the other groups. There was no significantdifference when comparing different adhesive systems andcomposite resins. Repairs performed at 7 days were betterthan those performed at 180 days. The composite repairsdecreased the mechanical strength of the restoration. Agingof the resin substrate may decrease repair bond strength overtime, regardless of the type of adhesive systems and resin composites used.


Avaliar a resistência de união ao cisalhamento de reparos deresina composta com e sem envelhecimento da superfície a serreparada, utilizando diferentes sistemas adesivos. Noventacorpos de prova foram confeccionados sendo: 10 para o GrupoControle (GC - sem reparo); 40 para o Grupo I (GI - reparosapós 7 dias) e 40 para o Grupo II (GII – reparos após 180 dias).Para os reparos, os grupos GI e GII foram subdivididos em 4subgrupos com 10 corpos de prova, variando o sistema adesivoe a resina composta: A) Adper Scotch Bond Multipurpose+Filtek Z350XT; B)Adper Single Bond Plus+ Filtek Z350XT;C)Adper Scotch Bond Multipurpose+ Esthet-X; D) AdperSingle Bond Plus+ Esthet-X. Os corpos de prova foramsubmetidos a uma força de cisalhamento em uma máquina deensaio universal (EMIC). Os resultados foram analisados peloteste estatístico Anova dois fatores, seguido pelo teste deFisher ́s. Observou-se melhor comportamento do grupocontrole sobre os demais grupos, além disso, os reparosrealizados aos 7 dias foram superiores aos dos realizados em180 dias. Não houve diferença significativaquando secomparou diferentes sistemas adesivos e resinas compostas.Os reparos de resina composta diminuem a resistênciamecânica da restauração.O envelheci mento do substrato deresina pode diminuir a resistência ao reparo ao longo dotempo, independentemente do tipo de sistemas adesivos eresinas compostas utilizados.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Reparación de Restauración Dental/métodos , Resinas Compuestas/uso terapéutico , Alisadura de la Restauración Dental/efectos adversos , Ensayo de Materiales , Resinas Compuestas/clasificación , Resistencia al Corte
8.
J Prosthodont ; 24(3): 194-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25143068

RESUMEN

PURPOSE: The prevalence of Candida infections has been rising with an increasingly aging population and a larger population of immunocompromised individuals. The use of probiotics may be an alternative approach to antifungal agents in the prevention and treatment of oral candidiasis. This study aimed to evaluate the short-term effect of probiotics in reducing the infection level of oral Candida in candidiasis-asymptomatic elderly denture wearers. MATERIALS AND METHODS: In a double-blind randomized study, 59 denture wearers harboring Candida spp. in the oral cavity with no clinical symptoms were allocated into two groups: probiotic and placebo. All patients were instructed to clean the denture daily. The probiotic group poured a capsule containing lyophilized Lactobacillus rhamnosus HS111, Lactobacillus acidophillus HS101, and Bifidobacterium bifidum daily on the palatal surface of the maxillary denture, whereas the placebo group was submitted to the same regimen using placebo capsules. Candida spp. infection levels were evaluated in palate mucosa samples obtained before and after a 5-week experimental period. RESULTS: All patients harbored Candida in the palate mucosa at baseline. Fifty-five individuals completed the experimental period. The detection rate of Candida spp. was 92.0% in the placebo group after the experimental period, whereas it was reduced to 16.7% in the probiotic group. The reduction promoted by the probiotic regimen was independent of baseline characteristics such as Candida infection level and colonizing species, age of denture, and other variables. CONCLUSION: The probiotic product was effective in reducing the colonization of the oral cavity with Candida in candidiasis-asymptomatic elderly denture wearers, suggesting that this multispecies probiotic could be used to prevent oral candidiasis. CLINICAL IMPLICATIONS: Colonization of oral surfaces by Candida is considered a risk factor for invasive fungal infections. The use of a product with L. rhamnosus, L. acidophilus, and B. bifidum may represent an alternative treatment for reduction of Candida infections in elderly denture wearers.


Asunto(s)
Candida/efectos de los fármacos , Candidiasis Bucal/prevención & control , Candidiasis Bucal/terapia , Dentaduras/microbiología , Boca/microbiología , Probióticos/uso terapéutico , Anciano , Bifidobacterium bifidum , Brasil , Alisadura de la Restauración Dental/efectos adversos , Método Doble Ciego , Femenino , Humanos , Lactobacillus acidophilus , Lacticaseibacillus rhamnosus , Masculino , Persona de Mediana Edad , Hueso Paladar/microbiología
9.
BMC Complement Altern Med ; 11: 119, 2011 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-22118215

RESUMEN

BACKGROUND: Candida-associated denture stomatitis is a frequent infectious disease. Treatment of this oral condition is difficult because failures and recurrences are common. The aim of this study was to test the in vitro antifungal activity of pure constituents of essentials oils. METHODS: Eight terpenic derivatives (carvacrol, farnesol, geraniol, linalool, menthol, menthone, terpinen-4-ol, and α-terpineol), a phenylpropanoid (eugenol), a phenethyl alcohol (tyrosol) and fluconazole were evaluated against 38 Candida isolated from denture-wearers and 10 collection Candida strains by the CLSI M27-A3 broth microdilution method. RESULTS: Almost all the tested compounds showed antifungal activity with MIC ranges of 0.03-0.25% for eugenol and linalool, 0.03-0.12% for geraniol, 0.06-0.5% for menthol, α-terpineol and terpinen-4-ol, 0.03-0.5% for carvacrol, and 0.06-4% for menthone. These compounds, with the exception of farnesol, menthone and tyrosol, showed important in vitro activities against the fluconazole-resistant and susceptible-dose dependent Candida isolates. CONCLUSIONS: Carvacrol, eugenol, geraniol, linalool and terpinen-4-ol were very active in vitro against oral Candida isolates. Their fungistatic and fungicidal activities might convert them into promising alternatives for the topic treatment of oral candidiasis and denture stomatitis.


Asunto(s)
Antifúngicos/farmacología , Productos Biológicos/farmacología , Candida/efectos de los fármacos , Candidiasis Bucal/microbiología , Alisadura de la Restauración Dental/efectos adversos , Aceites Volátiles/farmacología , Estomatitis Subprotética/microbiología , Candida/aislamiento & purificación , Candidiasis Bucal/tratamiento farmacológico , Candidiasis Bucal/etiología , Humanos , Pruebas de Sensibilidad Microbiana , Estomatitis Subprotética/tratamiento farmacológico , Estomatitis Subprotética/etiología
15.
Rev. Fac. Odontol. Bauru ; 8(3/4): 37-42, jul.-dez. 2000. ilus, tab
Artículo en Portugués | LILACS, BBO - Odontología | ID: lil-303986

RESUMEN

As resinas compostas vêm sofrendo aperfeiçoamento objetivando seu uso em dentes posteriores para substituir o amálgama dental, com a funçäo de melhorar a estética. Entretanto, problemas clínicos associados à sua utilizaçäo säo comumente observados, dentre eles sua resistência ao desgaste e à abrasäo, a contraçäo de polimerizaçäo, a microinfiltraçäo marginal, e sua deformaçäo permanente, importante propriedade em situaçöes clínicas onde existem áreas sujeitas às forças oclusais e que, normalmente näo é considerada. Visando determinar o "creep", por meio da deformaçäo permanente, espécimes confeccionadas com resinas compostas fotopoativadas: ALERT [A] (Jeneric (R)/Pentron (R)), CHARISMA F [C] (Heraeus/Kulzer), HELIOMOLAR RADIOPAQUE [H] (Vivadent), SOLITAIRE [S] (Heraeus/Kulzer) e TETRIC CERAM [T] (Vivadent) após armazenamento em água, à temperatura de 37º + 1ºC, foram submetidos a uma carga compressiva constante de 36MPa, por períodos de: 15 minutos, 1 hora e 24 horas. Os resultados obtidos apresentam os valores quantitativos da diferença entre o comprimento original da amostra e o seu comprimento após o ensaio, em cada período estabelecido. A análise estatística dos dados apresentados pelas cinco resinas, demonstrou resultados de "creep estático" (em ordem decrescente), para o período de 15 minutos: [H] (X=1,0192 por cento), [T] (X=0,8787 por cento), [C] (X=0,7469 por cento), [S] (X=0,6738 por cento) e [A] (X=0,5095 por cento). Para o período de 1 hora: [H] (X=1,5546 por cento), [T] (X=1,2082 por cento), [C] (X=0,9744 por cento), [S] (X0,8245 por cento), [A] (X=0,6348 por cento) e, para o último período observado, 24 horas, obteve-se a seguinte sequência: [H] (X=2,3747 por cento), [T] (X=1,7993 por cento), [C] (X=1,2812 por cento), [S] (X=1,2645 por cento) e [A] (X=0,7600 por cento). Os valores médios do "creep estático" das resinas CHARISMA F e SOLITAIRE näo foram estatisticamente diferentes entre si em qualquer um dos períodos estudados, sendo que no período de 15 minutos, os resultados obtidos para a resina TETRIC CERAM também se assemelharam aos destas e, em 1 hora, os da resina composta ALERT foram similares aos das duas primeiras; porém, a resina HELIOMOLAR RADIOPAQUE, apresentou resultados divergentes das anteriores, demonstrando piores características de deformaçäo permanente, por possuir maiores valores de "creep estático" em qualquer dos períodos estudados


Asunto(s)
Resinas Compuestas , Alisadura de la Restauración Dental/efectos adversos , Materiales Dentales/clasificación , Materiales Dentales/química
17.
Sucre; s.n; 14 mayo 1998. 56 p. ilus, tab, graf.
Tesis en Español | LIBOCS, LIBOSP | ID: biblio-1335566

RESUMEN

Las restauraciones realizadas con inclusiones de cristal resultaron eficases y eficientes como consecuencia de la buena resistencia. Gracias a la utilización de inclusiones de cristal en restauraciones posteriores se logró mejorar muchas de las propiedades de las resinas, lo que reprresenta una alternativa para el uso cotidiano del profesional que realiza obturaciones estéticas posteriores, La técnica empleada es sencilla; pudiendo ser concluida en una sola sesión operatoria como se había previsto. Hemos realizado untrabajo estadístico con el objeto de demostrar (mediante encuestas orales y exámenes clínicos) que los resultados obtenidos fueron los esperados


Asunto(s)
Masculino , Femenino , Humanos , Niño , Adulto , Alisadura de la Restauración Dental/clasificación , Alisadura de la Restauración Dental/efectos adversos , Alisadura de la Restauración Dental/psicología
18.
In. Gonçalves, Elenice Aparecida Nogueira; Feller, Christa. Atualizaçäo na clínica odontológica: a prática da clínica geral. Säo Paulo, Artes Médicas, 1998. p.325-66, ilus.
Monografía en Portugués | LILACS, BBO - Odontología | ID: lil-211068
19.
Bauru; s.n; 1998. 87 p. ilus, tab.
Tesis en Portugués | LILACS, BBO - Odontología | ID: lil-246475

RESUMEN

Este estudo foi conduzido de maneira a comparar a magnetude de três categorias de cimentos ionoméricos, quando submetidos ao teste de escovaçäo simulado. Foram preparados sessenta corpos de prova, distribuídos em seis grupos, sendo dez amostras para cada grupo. O cimento convencional Vidrion R, o resino-modificado Vitremer e o compômero Variglass, foram manipulados em duas condiçöes: manual e mecanicamente. Para determinaçäo do desgaste, utilizou-se uma máquina apropriada, com escova macia, soluçäo do dentifrício em água destilada e velocidade de 374 ciclos por minutos até 100.000 movimentos, o que corresponde a 4 horas e 45 minutos. A quantidade de massa perdida, em cada espécime, foi obtida, pela diferença entre a pesagem da massa inicial e a massa final, usando uma balança analítica de precisäo. Os resultados mostraram que houve desgaste nos cimentos, porém foram de extensöes diferentes. O maior grau de resistência foi, em ordem decrescente, para o Variglass, seguido pelo Vitremer e Vidrion R. O desgaste maior sempre foi para os cimentos manipulados manualmente e na mesma ordem acima


Asunto(s)
Humanos , Masculino , Femenino , Cementos de Ionómero Vítreo/química , Técnicas In Vitro , Cementos Dentales/química , Alisadura de la Restauración Dental/efectos adversos , Materiales Dentales/química , Restauración Dental Permanente/efectos adversos , Restauración Dental Permanente/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA