Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Front Immunol ; 12: 645632, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34012435

RESUMEN

Dysregulated autoantibodies and cytokines were deemed to provide important cues for potential illnesses, such as various carcinomas and autoimmune diseases. Increasing biotechnological approaches have been applied to screen and identify the specific alterations of these biomolecules as distinctive biomarkers in diseases, especially autoimmune diseases. As a versatile and robust platform, protein microarray technology allows researchers to easily profile dysregulated autoantibodies and cytokines associated with autoimmune diseases using various biological specimens, mainly serum samples. Here, we summarize the applications of protein microarrays in biomarker discovery for autoimmune diseases. In addition, the key issues in the process of using this approach are presented for improving future studies.


Asunto(s)
Enfermedades Autoinmunes/diagnóstico , Análisis por Matrices de Proteínas/métodos , Anticuerpos/análisis , Biomarcadores , Análisis Costo-Beneficio , Análisis de Datos , Humanos , Lectinas/análisis , Péptidos/análisis , Análisis por Matrices de Proteínas/economía , Proteoma
2.
Anal Bioanal Chem ; 408(22): 6009-17, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27007732

RESUMEN

Multiarray on a test strip (MATS) was developed for the detection of eight important potato pathogens. The proposed assay combines the rapidity of immunochromatography with the high throughput of array techniques. The test zone of the immunochromatographic strip comprises ordered rows of spots containing antibodies specific for different potato pathogens. The assay benefits from the simplicity of immunochromatography; colored immune complexes form at the corresponding spots within the test zone. The presence and intensity of the coloration are used for identification of the target pathogens. The MATS was applied to the simultaneous detection of eight priority potato pathogens, characterized by the following limits of detection: 1 ng/mL for potato virus X and the ordinary type of potato virus Y, 10 ng/mL for potato virus M, 20 ng/mL for potato leaf roll virus, 40 ng/mL for necrotic-type potato virus Y, 100 ng/mL for potato virus S, 300 ng/mL for potato virus A, and 10(4) cells/mL for Clavibacter michiganensis subsp. sepedonicus. Analysis time was 15 min. The observed sensitivity of the MATS was comparable to the traditional enzyme-linked immunosorbent assay. The developed technique was tested on potato leaf extracts, and its efficiency for on-site control of the pathogens was confirmed in 100 % by commercial LFIA test strips. Graphical abstract Location of binding zones in the developed multiarray on a test strip (MATS) for simultaneous detection of eight pathogens.


Asunto(s)
Cromatografía de Afinidad/métodos , Enfermedades de las Plantas/virología , Virus de Plantas/aislamiento & purificación , Tiras Reactivas/análisis , Solanum tuberosum/virología , Anticuerpos Inmovilizados/química , Cromatografía de Afinidad/economía , Cromatografía de Afinidad/instrumentación , Diseño de Equipo , Oro/química , Límite de Detección , Nanopartículas del Metal/química , Análisis por Matrices de Proteínas/economía , Análisis por Matrices de Proteínas/instrumentación , Análisis por Matrices de Proteínas/métodos
3.
Methods Mol Biol ; 1352: 67-83, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26490468

RESUMEN

With the increasing need for understanding antibody specificity in antibody and vaccine research, pepscan assays provide a rapid method for mapping and profiling antibody responses to continuous epitopes. We have developed a relatively low-cost method to generate peptide microarray slides for studying antibody binding. Using a setup of an IntavisAG MultiPep RS peptide synthesizer, a Digilab MicroGrid II 600 microarray printer robot, and an InnoScan 1100 AL scanner, the method allows the interrogation of up to 1536 overlapping, alanine-scanning, and mutant peptides derived from the target antigens. Each peptide is tagged with a polyethylene glycol aminooxy terminus to improve peptide solubility, orientation, and conjugation efficiency to the slide surface.


Asunto(s)
Anticuerpos/inmunología , Mapeo Epitopo/economía , Péptidos/inmunología , Análisis por Matrices de Proteínas/economía , Alanina/química , Secuencia de Aminoácidos , Celulosa/química , Fluorenos/química , Humanos , Proteínas Inmovilizadas/síntesis química , Proteínas Inmovilizadas/química , Proteínas Inmovilizadas/inmunología , Membranas Artificiales , Datos de Secuencia Molecular , Péptidos/síntesis química , Péptidos/química , Impresión
4.
Cell Commun Signal ; 13: 38, 2015 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-26297553

RESUMEN

Interactions between modular domains and short linear motifs (3-10 amino acids peptide stretches) are crucial for cell signaling. The motifs typically reside in the disordered regions of the proteome and the interactions are often transient, allowing for rapid changes in response to changing stimuli. The properties that make domain-motif interactions suitable for cell signaling also make them difficult to capture experimentally and they are therefore largely underrepresented in the known protein-protein interaction networks. Most of the knowledge on domain-motif interactions is derived from low-throughput studies, although there exist dedicated high-throughput methods for the identification of domain-motif interactions. The methods include arrays of peptides or proteins, display of peptides on phage or yeast, and yeast-two-hybrid experiments. We here provide a survey of scalable methods for domain-motif interaction profiling. These methods have frequently been applied to a limited number of ubiquitous domain families. It is now time to apply them to a broader set of peptide binding proteins, to provide a comprehensive picture of the linear motifs in the human proteome and to link them to their potential binding partners. Despite the plethora of methods, it is still a challenge for most approaches to identify interactions that rely on post-translational modification or context dependent or conditional interactions, suggesting directions for further method development.


Asunto(s)
Mapeo de Interacción de Proteínas/métodos , Mapas de Interacción de Proteínas , Proteínas/metabolismo , Secuencias de Aminoácidos , Ensayos Analíticos de Alto Rendimiento/economía , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Biblioteca de Péptidos , Péptidos/química , Péptidos/metabolismo , Análisis por Matrices de Proteínas/economía , Análisis por Matrices de Proteínas/métodos , Unión Proteica , Dominios y Motivos de Interacción de Proteínas , Mapeo de Interacción de Proteínas/economía , Proteínas/química , Proteómica/economía , Proteómica/métodos , Técnicas del Sistema de Dos Híbridos
5.
Clin Chem ; 61(10): 1283-91, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26283690

RESUMEN

BACKGROUND: The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report development and preliminary validation of an investigational assay meeting these requirements and demonstrate its applicability to cohorts of healthy individuals and patients with heart failure. METHODS: On the basis of single molecule array technology, we developed a 45-min immunoassay for cardiac troponin I (cTnI) for use on a novel, fully automated digital analyzer. We characterized its analytical performance and measured cTnI in healthy individuals and heart failure patients in a preliminary study of assay analytical efficacy. RESULTS: The assay exhibited a limit of detection of 0.01 ng/L, a limit of quantification of 0.08 ng/L, and a total CV of 10% at 2.0 ng/L. cTnI concentrations were well above the assay limit of detection for all samples tested, including samples from healthy individuals. cTnI was significantly higher in heart failure patients, and exhibited increasing median and interquartile concentrations with increasing New York Heart Association classification of heart failure severity. CONCLUSIONS: The robust 2-log increase in sensitivity relative to contemporary high-sensitivity cardiac troponin immunoassays, combined with full automation, make this assay suitable for exploring cTnI concentrations in cohorts of healthy individuals and for the potential prognostic application of serial cardiac troponin measurements in both apparently healthy and diseased individuals.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Inmunoensayo/métodos , Troponina I/sangre , Adulto , Femenino , Insuficiencia Cardíaca/sangre , Humanos , Inmunoensayo/economía , Límite de Detección , Masculino , Persona de Mediana Edad , Análisis por Matrices de Proteínas/economía , Análisis por Matrices de Proteínas/métodos , Troponina I/análisis , Adulto Joven
6.
Fetal Diagn Ther ; 36(1): 49-58, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24943865

RESUMEN

INTRODUCTION: To determine the cost-effectiveness of prenatal chromosomal microarray (CMA) when performed for structural anomalies on fetal ultrasound scan over conventional techniques. METHOD: A decision tree was populated using data from a prospective cohort of women undergoing testing when a fetal ultrasound scan showed a structural abnormality. Nine strategies of testing were modeled including combinations of the tests: QFPCR, G-band karyotyping, CMA and FISH for DiGeorge (22q) microdeletion. RESULTS: When CMA costs GBP 405 and using a 1-Mb BAC array it would cost GBP 24,600 for every additional case detected by CMA over a combination of QFPCR, followed by G-band karyotype, followed lastly by FISH (for DiGeorge syndrome). If CMA is performed instead of conventional karyotyping alone it costs GBP 33,000 for every additional case detected. However, if the cost of CMA is reduced to GBP 360 than when CMA is performed instead of conventional karyotyping alone it would cost GBP 9,768 for every additional case detected. DISCUSSION: The use of a prenatal BAC CMA is not currently cost-effective when compared to other testing strategies. However, as CMA costs decrease and resolution (and detection rates) increase it is likely to become the cost-effective option of the future.


Asunto(s)
Trastornos de los Cromosomas/economía , Trastornos de los Cromosomas/genética , Cromosomas Artificiales Bacterianos/genética , Análisis Costo-Beneficio/métodos , Análisis por Matrices de Proteínas/economía , Ultrasonografía Prenatal/economía , Aberraciones Cromosómicas/embriología , Trastornos de los Cromosomas/diagnóstico , Árboles de Decisión , Femenino , Humanos , Cariotipificación/economía , Cariotipificación/métodos , Embarazo , Diagnóstico Prenatal/economía , Diagnóstico Prenatal/métodos , Estudios Prospectivos , Análisis por Matrices de Proteínas/métodos , Ultrasonografía Prenatal/métodos
7.
Talanta ; 100: 405-9, 2012 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-23141356

RESUMEN

The use of antibody-based diagnostic testing has increased significantly over the past decade, giving rise to a wide range of diagnostic devices. At one end of the cost-range are rapid inexpensive point-of-care tests based on immunochromatographic strips which provide a qualitative positive or negative test outcome. On the other hand, quantitative tests generally require the use of dedicated and expensive laboratory instruments. There remains a need for diagnostic instruments and tests that can provide quantitative assessment of disease markers at low cost. This paper describes the development of a novel low cost optical device for reading colorimetric and fluorescent immunodiagnostic test results. This portable instrument uses a webcam to capture test results from a specially designed 16-well slide containing a miniaturized array of test spots. Arrays are illuminated with either LEDs or lasers, while transmitted or emitted light is captured through a long-pass filter, allowing two different types of optical measurement to be performed within the same device. This device was used to read results from an array of antibodies conjugated with either an enzymatic or fluorescent tag resulting in a colored or fluorescent readout.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/economía , Ensayo de Inmunoadsorción Enzimática/instrumentación , Dispositivos Ópticos/economía , Análisis por Matrices de Proteínas/economía , Análisis por Matrices de Proteínas/instrumentación , Colorimetría , Espectrometría de Fluorescencia
9.
Anal Biochem ; 424(1): 45-53, 2012 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-22342946

RESUMEN

Low-affinity extracellular protein interactions are critical for cellular recognition processes, but existing methods to detect them are limited in scale, making genome-wide interaction screens technically challenging. To address this, we report here the miniaturization of the AVEXIS (avidity-based extracellular interaction screen) assay by using protein microarray technology. To achieve this, we have developed protein tags and sample preparation methods that enable the parallel purification of hundreds of recombinant proteins expressed in mammalian cells. We benchmarked the protein microarray-based assay against a set of known quantified receptor-ligand pairs and show that it is sensitive enough to detect even very weak interactions that are typical of this class of interactions. The increase in scale enables interaction screening against a dilution series of immobilized proteins on the microarray enabling the observation of saturation binding behaviors to show interaction specificity and also the estimation of interaction affinities directly from the primary screen. These methodological improvements now permit screening for novel extracellular receptor-ligand interactions on a genome-wide scale.


Asunto(s)
Espacio Extracelular/metabolismo , Análisis por Matrices de Proteínas/métodos , Mapeo de Interacción de Proteínas/métodos , Proteínas Recombinantes/metabolismo , Secuencia de Aminoácidos , Animales , Biotinilación , Análisis Costo-Beneficio , Células HEK293 , Humanos , Proteínas Inmovilizadas , Datos de Secuencia Molecular , Análisis por Matrices de Proteínas/economía , Unión Proteica , Mapeo de Interacción de Proteínas/economía , Proteínas Recombinantes/química , Proteínas Recombinantes/aislamiento & purificación , Estreptavidina/metabolismo , Técnicas de Cultivo de Tejidos , Pez Cebra , Proteínas de Pez Cebra/metabolismo
10.
Anal Bioanal Chem ; 401(8): 2549-59, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21881881

RESUMEN

Hepatitis C virus (HCV) is a major cause of chronic liver disease and liver cancer, and remains a large health care burden to the world. In this study we developed a DNA microarray test to detect HCV RNA and a protein microarray to detect human anti-HCV antibodies on a single platform. A main focus of this study was to evaluate possibilities to reduce the assay time, as a short time-to-result (TTR) is a prerequisite for a point-of-care test. Significantly reducing hybridisation and washing times did not impair the assay performance. This was confirmed first using artificial targets and subsequently using clinical samples from an HCV seroconversion panel derived from a HCV-infected patient. We were able to reduce the time required for the detection of human anti-HCV antibodies to only 14 min, achieving nanomolar sensitivity. The protein microarray exhibited an analytical sensitivity comparable to that of commercial systems. Similar results were obtained with the DNA microarray using a universal probe which covered all different HCV genotypes. It was possible to reduce the assay time after PCR from 150 min to 16 min without any loss of sensitivity. Taken together, these results constitute a significant step forward in the design of rapid, microarray-based diagnostics for human infectious disease, and show that the protein microarray is currently the most favourable candidate to fill this role.


Asunto(s)
Hepacivirus/aislamiento & purificación , Hepatitis C/diagnóstico , Análisis de Secuencia por Matrices de Oligonucleótidos/economía , Análisis por Matrices de Proteínas/economía , ADN Viral/aislamiento & purificación , Anticuerpos contra la Hepatitis C/análisis , Humanos , Análisis de Secuencia por Matrices de Oligonucleótidos/métodos , Análisis por Matrices de Proteínas/métodos , ARN Viral/aislamiento & purificación , Sensibilidad y Especificidad , Factores de Tiempo
11.
Anal Biochem ; 414(1): 99-102, 2011 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-21371419

RESUMEN

We have developed a fibrinogen-specific sandwich enzyme-linked immunosorbent assay (ELISA) microarray assay for use in qualitatively distinguishing between blood plasma and serum samples. Three capture antibodies (49D2, HPA001900, and F8512) were evaluated in conjunction with 1D6 as the detection antibody. The data show that 49D2 and (to a lesser extent) F8512 successfully identify previously unknown plasma and serum samples based on approximately a 28-fold difference in signal intensity between the sample types. This assay has utility in rapidly identifying previously archived clinical samples with incomplete annotation in a high-throughput manner prior to proteomic analyses.


Asunto(s)
Ensayo de Inmunoadsorción Enzimática/métodos , Fibrinógeno/análisis , Plasma/química , Análisis por Matrices de Proteínas/métodos , Suero/química , Animales , Anticuerpos/análisis , Anticuerpos/inmunología , Anticuerpos Monoclonales , Ensayo de Inmunoadsorción Enzimática/economía , Ensayo de Inmunoadsorción Enzimática/instrumentación , Diseño de Equipo , Fibrinógeno/inmunología , Humanos , Análisis por Matrices de Proteínas/economía , Análisis por Matrices de Proteínas/instrumentación , Proteómica/economía , Proteómica/instrumentación , Proteómica/métodos , Sensibilidad y Especificidad
12.
Methods Mol Biol ; 723: 185-200, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21370066

RESUMEN

In this chapter, we present a novel, cost-effective microarray strategy that utilizes expression-ready plasmid DNAs to generate protein arrays on-demand and its use to validate protein-protein interactions. These expression plasmids were constructed in such a way so as to serve a dual purpose of synthesizing the protein of interest as well as capturing the synthesized protein. The microarray system is based on the high affinity binding of Escherichia coli "Tus" protein to "Ter," a 20 bp DNA sequence involved in the regulation of DNA replication. The protein expression is carried out in a cell-free protein synthesis system, with rabbit reticulocyte lysates, and the target proteins are detected either by labeled incorporated tag specific or by gene-specific antibodies. This microarray system has been successfully used for the detection of protein-protein interaction because both the target protein and the query protein can be transcribed and translated simultaneously in the microarray slides. The utility of this system for detecting protein-protein interaction is demonstrated by a few well-known examples: Jun/Fos, FRB/FKBP12, p53/MDM2, and CDK4/p16. In all these cases, the presence of protein complexes resulted in the localization of fluorophores at the specific sites of the immobilized target plasmids. Interestingly, during our interactions studies we also detected a previously unknown interaction between CDK2 and p16. Thus, this Tus-Ter based system of protein microarray can be used for the validation of known protein interactions as well as for identifying new protein-protein interactions. In addition, it can be used to examine and identify targets of nucleic acid-protein, ligand-receptor, enzyme-substrate, and drug-protein interactions.


Asunto(s)
Proteínas de Unión al ADN/metabolismo , Proteínas de Escherichia coli/metabolismo , Análisis por Matrices de Proteínas/métodos , Animales , Anticuerpos/inmunología , Anticuerpos/metabolismo , Carbocianinas/aislamiento & purificación , Carbocianinas/metabolismo , Clonación Molecular , Proteínas de Unión al ADN/genética , Proteínas de Unión al ADN/inmunología , Escherichia coli , Proteínas de Escherichia coli/genética , Proteínas de Escherichia coli/inmunología , Hibridación de Ácido Nucleico , Plásmidos/genética , Impresión , Análisis por Matrices de Proteínas/economía , Unión Proteica , Control de Calidad
13.
Mol Biosyst ; 6(11): 2241-8, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20859568

RESUMEN

Antibody microarrays are among the novel class of rapidly emerging proteomic technologies that will allow us to efficiently perform specific diagnoses and proteomic analysis. Recombinant antibody fragments are especially suited for this approach but their stability is often a limiting factor. Camelids produce functional antibodies devoid of light chains (HCAbs) of which the single N-terminal domain is fully capable of antigen binding. When produced as an independent domain, these so-called single domain antibody fragments (sdAbs) have several advantages for biotechnological applications thanks to their unique properties of size (15 kDa), stability, solubility, and expression yield. These features should allow sdAbs to outperform other antibody formats in a number of applications, notably as capture molecules for antibody arrays. In this study, we have produced antibody microarrays using direct and oriented immobilization of sdAbs, produced in crude bacterial lysates, to generate a proof-of-principle of a high-throughput compatible array design. Several sdAb immobilization strategies have been explored. Immobilization of in vivo biotinylated sdAbs by direct spotting of bacterial lysate on streptavidin and sandwich detection was developed to achieve high sensitivity and specificity, whereas immobilization of "multi-tagged" sdAbs via anti-tag antibodies and a direct labeled sample detection strategy was optimized for the design of high-density antibody arrays for high-throughput proteomics and identification of potential biomarkers.


Asunto(s)
Anticuerpos/metabolismo , Bacterias/metabolismo , Mezclas Complejas/metabolismo , Ensayos Analíticos de Alto Rendimiento/economía , Ensayos Analíticos de Alto Rendimiento/métodos , Proteínas Inmovilizadas/metabolismo , Análisis por Matrices de Proteínas/economía , Antígenos/inmunología , Biomarcadores de Tumor/inmunología , Biotinilación , Antígeno Carcinoembrionario/inmunología , Extractos Celulares , Línea Celular , Análisis Costo-Beneficio , Citoplasma/metabolismo , Escherichia coli/metabolismo , Humanos , Inmunoensayo
14.
J Microbiol Methods ; 80(3): 274-80, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20093147

RESUMEN

The use of antibody-based miniaturized devices for microbiological applications is a field poorly investigated in the era of more developed molecular amplification techniques. A novel antibody microarray for Streptococcus pneumoniae serotyping was developed, by printing nanolitre volumes of pneumococcal serotype-specific antibodies on multi-well slides. This microarray, which showed high specificity when tested against reference and clinical S. pneumoniae isolates, can be applicable as a faster, cost-effective and accurate serotyping technique for pneumococcal epidemiological studies.


Asunto(s)
Infecciones Neumocócicas/microbiología , Análisis por Matrices de Proteínas/métodos , Streptococcus pneumoniae/clasificación , Adulto , Anticuerpos Antibacterianos/inmunología , Niño , Humanos , Análisis por Matrices de Proteínas/economía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Serotipificación/economía , Serotipificación/métodos , Streptococcus pneumoniae/inmunología , Streptococcus pneumoniae/aislamiento & purificación , Factores de Tiempo
15.
Ann Intern Med ; 151(4): 270-3, W95, 2009 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-19687493

RESUMEN

The U.S. Food and Drug Administration modified warfarin labeling in 2007 to suggest, but not mandate, pharmacogenetic testing. Genetic analysis is now commercially available. However, results predict only one third of all dosing variation, the value of testing in reducing bleeding and thrombosis rates remains unproved, and cost-effectiveness is not established. Careful consideration of clinical factors that influence dosing, conscientious prothrombin time monitoring, and sage dosage adjustment remain paramount in warfarin management. Further study is required before routine warfarin pharmacogenetic testing can be recommended.


Asunto(s)
Anticoagulantes/administración & dosificación , Hidrocarburo de Aril Hidroxilasas/genética , Oxigenasas de Función Mixta/genética , Análisis por Matrices de Proteínas/economía , Warfarina/administración & dosificación , Anticoagulantes/efectos adversos , Anticoagulantes/metabolismo , Análisis Costo-Beneficio , Citocromo P-450 CYP2C9 , Hemorragia/genética , Hemorragia/prevención & control , Humanos , Polimorfismo de Nucleótido Simple , Etiquetado de Productos , Trombosis/genética , Trombosis/prevención & control , Estados Unidos , United States Food and Drug Administration , Vitamina K Epóxido Reductasas , Warfarina/efectos adversos , Warfarina/metabolismo
16.
Proteomics ; 9(15): 3945-8, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19637236

RESUMEN

The technique of UV-light-assisted immobilization of disulfide containing proteins has been combined with the Fourier-transforming properties of lenses as well as with a simple millimeter scale feature size spatial mask. The result is a new simple and inexpensive way of creating high-density protein arrays with feature sizes down to a few hundred nanometers, which represents an improvement of tenfold over existing commercially available high-density protein arraying methods.


Asunto(s)
Disulfuros/química , Proteínas Inmovilizadas/análisis , Análisis por Matrices de Proteínas/métodos , Rayos Ultravioleta , Análisis de Fourier , Proteínas Inmovilizadas/química , Óptica y Fotónica , Análisis por Matrices de Proteínas/economía
17.
Anal Chem ; 81(11): 4296-301, 2009 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-19408947

RESUMEN

Surface Plasmon Resonance Microscopy (SPRM) is a promising label-free analytical tool for the real-time study of biomolecule interactions in a microarray format. However, flow cell design and microarray fabrication have hindered throughput and limited applications of SPRM. Here we report the integration of a microfluidic flow cell array (MFCA) with SPRM enabling in situ microarray fabrication and multichannel analysis of biomolecule probe-target interactions. We demonstrate the use of the MFCA for delivery of sample solutions with continuous flow in 24 channels in parallel for rapid microarray creation and binding analysis while using SPRM for real-time monitoring of these processes. Label-free measurement of antibody-antibody interactions demonstrates the capabilities of the integrated MFCA-SPRM system and establishes the first steps of the development of a high-throughput, label-free immunogenicity assay. After in situ probe antibody immobilization, target antibody binding was monitored in real time in 24 channels simultaneously. The limit of detection for this particular antibody pair is 80 ng/mL which is approximately 6 times lower than the industry recommended immunogenicity assay detection limit. The integrated MFCA-SPRM system is a powerful and versatile combination for a range of array-based analyses, including biomarker screening and drug discovery.


Asunto(s)
Anticuerpos/análisis , Anticuerpos/inmunología , Técnicas Analíticas Microfluídicas/instrumentación , Análisis por Matrices de Proteínas/instrumentación , Resonancia por Plasmón de Superficie/métodos , Animales , Anticuerpos Inmovilizados , Biotinilación , Calibración , Diseño de Equipo , Cabras , Humanos , Inmunoglobulina G/análisis , Inmunoglobulina G/inmunología , Técnicas Analíticas Microfluídicas/economía , Técnicas Analíticas Microfluídicas/métodos , Análisis por Matrices de Proteínas/economía , Análisis por Matrices de Proteínas/métodos , Sensibilidad y Especificidad , Estreptavidina , Resonancia por Plasmón de Superficie/instrumentación
18.
Nat Protoc ; 2(6): 1333-49, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17545971

RESUMEN

Peptide synthesis on cellulose using SPOT technology allows the parallel synthesis of large numbers of addressable peptides in small amounts. In addition, the cost per peptide is less than 1% of peptides synthesized conventionally on resin. The SPOT method follows standard fluorenyl-methoxy-carbonyl chemistry on conventional cellulose sheets, and can utilize more than 600 different building blocks. The procedure involves three phases: preparation of the cellulose membrane, stepwise coupling of the amino acids and cleavage of the side-chain protection groups. If necessary, peptides can be cleaved from the membrane for assays performed using soluble peptides. These features make this method an excellent tool for screening large numbers of peptides for many different purposes. Potential applications range from simple binding assays, to more sophisticated enzyme assays and studies with living microbes or cells. The time required to complete the protocol depends on the number and length of the peptides. For example, 400 9-mer peptides can be synthesized within 6 days.


Asunto(s)
Celulosa/química , Péptidos/síntesis química , Análisis por Matrices de Proteínas/economía , Análisis por Matrices de Proteínas/métodos , Secuencia de Aminoácidos , Técnicas Químicas Combinatorias , Mapeo Epitopo/métodos , Biblioteca de Péptidos , Péptidos/química , Factores de Tiempo
19.
Anal Biochem ; 365(2): 266-73, 2007 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-17459319

RESUMEN

Multiplexing of G protein-coupled receptors (GPCRs) in microarrays promises to increase the efficiency, reduce the costs, and improve the quality of high-throughput assays. However, this technology is still nascent and has not yet achieved the status of "high throughput" or laid claim to handling a large set of receptors. In addition, the technology has been demonstrated only when using fluorescent ligands to detect binding, limiting its application to a subset of GPCRs. To expand the impact of multiplexing on this receptor class, we have developed a radiometric approach to the microarray assay. In these studies, we considered two receptors in the alpha-adrenergic receptor family, alpha2A and alpha2C, and the 125I-labeled agonist clonidine. We demonstrate that microarrays of these receptors can be readily detected (signal/noise ratio approximately 160) using a Typhoon 9210 PhosphorImager. In addition, biochemical characterization shows that ligand-binding profiles and selectivity are preserved with the selective antagonists BRL44408 and ARC239. Importantly, these microarrays use approximately 200- to 400-fold less membrane preparation required by conventional assay methods and allow two or more receptors to be assayed in an area equivalent to a standard well of a microtiter plate. The impact of this approach on screening in drug discovery is discussed.


Asunto(s)
Análisis por Matrices de Proteínas/métodos , Ensayo de Unión Radioligante/instrumentación , Ensayo de Unión Radioligante/métodos , Receptores Acoplados a Proteínas G/química , Antagonistas Adrenérgicos alfa/química , Animales , Línea Celular , Clonidina/análisis , Cricetinae , Humanos , Imidazoles/química , Indoles/química , Isoindoles , Isoquinolinas/química , Piperazinas/química , Análisis por Matrices de Proteínas/economía , Unión Proteica , Receptores Adrenérgicos/química
20.
World J Gastroenterol ; 12(25): 4044-8, 2006 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-16810756

RESUMEN

AIM: To detect multiple H. pylori antibodies in serum samples of individuals who carry H. pylori by protein array. METHODS: Recombinant H. pylori antigens, urease B subunit (UreB), vacuolating toxin A (VacA) and cytotoxin associated gene A protein (CagA), were prepared and immobilized in matrixes on nitrocellulose membrane by robotics to bind the specific immunoglobulin G (IgG) antibodies in serum. Staphylococcus protein A (SPA) labeled by colloid gold was used to integrate the immuno-complex and gave red color signal. The scanner based on charge-coupled device (CCD) could collect the image signal and convert it into digital signal. RESULTS: When human IgG was printed on the membrane in increasing concentrations and incubated with immunogold, a linear dose response curve was obtained and the detection limit for IgG was about 0.025 ng. The cutoff values, which were defined as the mean grey level plus 3 times of standard deviation, were 27.183, 28.546 and 27.402, for anti-UreB IgG, anti-CagA IgG and anti-VacA IgG, respectively, as 400 human serum samples with negative H. pylori antibodies were detected by the protein array. When 180 serum samples from patients in hospital were employed for detection of IgG against UreB, CagA and VacA, the sensitivity of the protein array was 93.4%, 95.4%, 96.0%, and the specificity was 94.8%, 94.4% and 97.5%, respectively, as compared with the results obtained by ELISA. The assay also showed high reproducibility, uniformity and stability, and the results were available within 30 min. CONCLUSION: The protein array is a very practical method for rapid detection of multiple antibodies in serum samples. It is especially useful for large scale epidemiological investigation of the infection of H. pylori.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Helicobacter pylori/inmunología , Análisis por Matrices de Proteínas/instrumentación , Antígenos Bacterianos , Humanos , Análisis por Matrices de Proteínas/economía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Suero/química , Gastropatías/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...