1.
Can Assoc Radiol J ; 74(4): 737-744, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37023704

RESUMEN

Purpose: Angiographic equipment is a key component of healthcare infrastructure, used for endovascular procedures throughout the body. The literature on adverse events related to this technology is limited. The purpose of this study was to analyze adverse events related to angiographic devices from the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database. Methods: MAUDE data on angiographic imaging equipment from July 2011 to July 2021 were extracted. Qualitative content analysis was performed, a typology of adverse events was derived, and this was used to classify the data. Outcomes were assessed using the Healthcare Performance Improvement (HPI) and Society of Interventional Radiology (SIR) adverse event classifications. Results: There were 651 adverse events reported. Most were near misses (67%), followed by precursor safety events (20.5%), serious safety events (11.2%), and unclassifiable (1.2%). Events impacted patients (42.1%), staff (3.2%), both (1.2%), or neither (53.5%). The most common events associated with patient harm were intra-procedure system shut down, foot pedal malfunction, table movement malfunction, image quality deterioration, patient falls, and fluid damage to system. Overall, 34 (5.2%) events were associated with patient death; 18 during the procedure and 5 during patient transport to another angiographic suite/hospital due to critical failure of equipment. Conclusion: Adverse events related to angiographic equipment are rare; however, serious adverse events and deaths have been reported. This study has defined a typology of the most common adverse events associated with patient and staff harm. Increased understanding of these failures may lead to improved product design, user training, and departmental contingency planning.


Asunto(s)
Angiografía , Humanos , Bases de Datos Factuales , Estados Unidos , Angiografía/efectos adversos , Angiografía/instrumentación
2.
IEEE Trans Med Imaging ; 42(4): 1009-1020, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36383595

RESUMEN

Optical Coherence Tomography Angiography (OCTA), a functional extension of OCT, has the potential to replace most invasive fluorescein angiography (FA) exams in ophthalmology. So far, OCTA's field of view is however still lacking behind fluorescence fundus photography techniques. This is problematic, because many retinal diseases manifest at an early stage by changes of the peripheral retinal capillary network. It is therefore desirable to expand OCTA's field of view to match that of ultra-widefield fundus cameras. We present a custom developed clinical high-speed swept-source OCT (SS-OCT) system operating at an acquisition rate 8-16 times faster than today's state-of-the-art commercially available OCTA devices. Its speed allows us to capture ultra-wide fields of view of up to 90 degrees with an unprecedented sampling density and hence extraordinary resolution by merging two single shot scans with 60 degrees in diameter. To further enhance the visual appearance of the angiograms, we developed for the first time a three-dimensional deep learning based algorithm for denoising volumetric OCTA data sets. We showcase its imaging performance and clinical usability by presenting images of patients suffering from diabetic retinopathy.


Asunto(s)
Angiografía , Oftalmología , Enfermedades de la Retina , Tomografía de Coherencia Óptica , Humanos , Retinopatía Diabética/diagnóstico por imagen , Angiografía con Fluoresceína/normas , Enfermedades de la Retina/diagnóstico por imagen , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/normas , Angiografía/instrumentación , Angiografía/métodos , Angiografía/normas , Oftalmología/instrumentación , Oftalmología/métodos
3.
Sci Rep ; 11(1): 21052, 2021 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-34702941

RESUMEN

Photonic integrated circuits (PIC) provide promising functionalities to significantly reduce the size and costs of optical coherence tomography (OCT) systems. This paper presents an imaging platform operating at a center wavelength of 830 nm for ophthalmic application using PIC-based swept source OCT. An on-chip Mach-Zehnder interferometer (MZI) configuration, which comprises an input power splitter, polarization beam splitters in the sample and the reference arm, and a 50/50 coupler for signal interference represents the core element of the system with a footprint of only [Formula: see text]. The system achieves 94 dB imaging sensitivity with 750 [Formula: see text]W on the sample, 50 kHz imaging speed and 5.5 [Formula: see text]m axial resolution (in soft tissue). With this setup, in vivo human retinal imaging of healthy subjects was performed producing B-scans, three-dimensional renderings as well as OCT angiography. These promising results are significant prerequisites for further integration of optical and electronic building blocks on a single swept source-OCT PIC.


Asunto(s)
Angiografía/instrumentación , Diseño de Equipo , Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/instrumentación , Angiografía/métodos , Humanos , Tomografía de Coherencia Óptica/métodos
4.
Arq. bras. oftalmol ; 84(3): 235-240, May-June 2021. tab
Artículo en Inglés | LILACS | ID: biblio-1248975

RESUMEN

ABSTRACT Purposes: To evaluate the optical coherence tomography angiography findings in patients with Behçet disease with and without ocular involvement. Methods: A total of 40 patients with Behçet disease and 30 healthy controls were enrolled in the study. Retinal vessel density in the superficial capillary plexus and deep capillary plexus, foveal avascular zone area and perimeter, acirculatory index, foveal density, and nonflow area in the superficial retina were automatically measured using the optical coherence tomography angiography software AngioVue and compared between the groups. Results: The mean parafoveal and perifoveal vessel densities in the superficial capillary plexus and deep capillary plexus and foveal density were significantly lower in the eyes with Behçet uveitis compared to the eyes without Behçet uveitis and eyes of the healthy controls. In the eyes with Behçet uveitis, logMAR visual acuity showed a moderate correlation with parafoveal and perifoveal vessel densities and foveal density (r=-0.43, p=0.006; r=-0.62, p<0.001; r=-0.42, p=0.008; respectively). Conclusion: Behçet disease with posterior uveitis was associated with significant perifoveal and parafoveal vascular decrements in the superficial and deep retina.(AU)


RESUMO Objetivo: Avaliar achados de angiografia por tomografia de coerência óptica em pacientes com doença de Behçet com e sem acometimento ocular. Métodos: Foram incluídos 40 pacientes com doença de Behçet e 30 controles saudáveis. A densidade vascular retiniana nos plexos capilares superficial e profundo, a zona avascular foveal, o índice de circularidade, a densidade foveal e a área sem fluxo da retina superficial foram medidos automaticamente, através do software AngioVue para angiografia por tomografia de coerência óptica, e comparados entre os grupos. Resultados: A densidade vascular parafoveal e perifoveal média nos plexos capilares superficial e profundo, bem como a densidade foveal, foram significativamente menores nos olhos com uveíte de Behçet em comparação com os olhos sem uveíte de Behçet e os olhos dos controles saudáveis. Nos olhos com uveíte de Behçet, a acuidade visual logMAR mostrou correlação moderada com a densidade vascular parafoveal e perifoveal e com a densidade foveal (respectivamente, r=-0,43, p=0,006; r=-0,62, p<0,001; e r=-0,42, p = 0,008). Conclusão: A doença de Behçet com uveíte posterior foi associada a decréscimos significativos da vascularização perifoveal e parafoveal na retina superficial e profunda.(AU)


Asunto(s)
Humanos , Uveítis/patología , Angiografía/instrumentación , Síndrome de Behçet/fisiopatología , Tomografía de Coherencia Óptica/instrumentación , Fóvea Central/irrigación sanguínea
5.
Biomed Res Int ; 2021: 5564462, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33977105

RESUMEN

A 125 cm long catheter makes it possible to perform renal arteriography via radial artery, but its feasibility and safety remain unclear. Our study recruited 1,323 patients grouped by two different vascular accesses to renal arteriography, i.e., femoral artery access and radial artery access. The success rate of angiography was 100% in both groups. Differential analysis showed that the overall complication incidence of radial artery access group was significantly lower (2.5% for radial artery access vs. 4.8% for femoral artery access, p = 0.03). From this study, we suggest that using the 125 cm angiographic catheter to perform renal arteriography via radial artery access is feasible and safe.


Asunto(s)
Angiografía , Catéteres/efectos adversos , Riñón , Arteria Radial/cirugía , Arteria Renal/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Angiografía/efectos adversos , Angiografía/instrumentación , Angiografía/métodos , Femenino , Arteria Femoral/cirugía , Humanos , Riñón/irrigación sanguínea , Riñón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
6.
J Vasc Interv Radiol ; 32(2): 220-225.e2, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33461874

RESUMEN

PURPOSE: To evaluate the impact of a versatile flexible ceiling-mounted C-arm on active table and gantry repositioning during interventions and its effect on operator discomfort, system usability, and patient safety compared with a traditional ceiling-mounted system. MATERIALS AND METHODS: There were 100 IR procedures studied: 50 in a traditional IR system (standard group) and 50 with a novel multiaxis ceiling-mounted system (test group). FlexArm was capable of multiple gantry rotation points allowing increased access to the patient in addition to 236 cm of lateral x-ray detector travel. For each procedure, both the table and the gantry repositioning were measured. Patient safety, patient/equipment repositioning effort, and physical discomfort were evaluated through an operator survey. RESULTS: Table repositioning was reduced from 42 to 16 instances per procedure (P < .001) in the test group compared with the standard group. The operators perceived less table and gantry repositioning effort (P < .0001) and decreased risks of equipment collisions, displacement of vascular access, and dislodgment of tubes/lines with the test group (P < .0001). Operator discomfort was reduced for all body areas in the test group over the standard group (P < .0001). CONCLUSIONS: The FlexArm system geometry enhances operator ergonomics, as there was a decrease need to move the table, leading to a perceived decrease in patient risk and decrease operator physical discomfort when compared to a traditional imaging system.


Asunto(s)
Angiografía/instrumentación , Ergonomía , Radiografía Intervencional/instrumentación , Radiólogos , Angiografía/efectos adversos , Diseño de Equipo , Humanos , Enfermedades Musculoesqueléticas/etiología , Enfermedades Musculoesqueléticas/prevención & control , Enfermedades Profesionales/etiología , Enfermedades Profesionales/prevención & control , Salud Laboral , Posicionamiento del Paciente , Seguridad del Paciente , Estudios Prospectivos , Radiografía Intervencional/efectos adversos , Flujo de Trabajo
8.
Ann Vasc Surg ; 71: 273-279, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32890647

RESUMEN

BACKGROUND: Fusion imaging makes it possible to improve endovascular procedures and is mainly used in hybrid rooms for aortic procedures. The objective of this study was to evaluate the feasibility of fusion imaging for femoropopliteal endovascular procedures with a mobile flat plane sensor and dedicated software to assist endovascular navigation. MATERIALS AND METHODS: Between May and December 2017, 41 patients requiring femoropopliteal endovascular revascularization were included. Interventions were carried out in a conventional surgical room equipped with a mobile plane sensor (Cios Alpha, Siemens). The numerical video stream was transmitted to an angionavigation station (EndoNaut (EN), Therenva). The software created an osseous and arterial panorama of the treated limb from the angiographies carried out at the beginning of procedure. After each displacement of the table, the software relocated the current image on the osseous panorama, with 2D-2D resetting, and amalgamated the mask of the arterial panorama. The success rates of creation of osseous and arterial panorama and the success of relocation were evaluated. The data concerning irradiation, the volume of contrast (VC) injected, and operative times were recorded. RESULTS: Osseous panoramas could be automatically generated for the 41 procedures, without manual adjustment in 33 cases (80.5%). About 35 relocations based on a 2D-2D resetting could be obtained in the 41 procedures, with a success rate of 85%. The causes of failure were a change in table height or arch angulation. The average duration of intervention was 74.5 min. The irradiation parameters were duration of fluoroscopy 17.8 ± 13.1 min, air kerma 80.5 ± 68.4 mGy, and dose area product 2140 ± 1599 µGy m2. The average VC was 24.5 ± 14 mL. CONCLUSIONS: This preliminary study showed that fusion imaging is possible in a nonhybrid room for peripheral procedures. Imagery of mobile C-arms can be improved for femoropopliteal endovascular procedures without heavy equipment. These imagery tools bring an operative comfort and could probably reduce irradiation and the injected VC. The clinical benefit must be evaluated in more patients in a randomized comparative study with a rigorous methodology.


Asunto(s)
Angiografía/instrumentación , Procedimientos Endovasculares/instrumentación , Arteria Femoral/diagnóstico por imagen , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Intervencional/instrumentación , Terapia Asistida por Computador/instrumentación , Anciano , Anciano de 80 o más Años , Procedimientos Endovasculares/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Quirófanos , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Radiografía Intervencional/efectos adversos , Programas Informáticos , Factores de Tiempo , Resultado del Tratamiento
9.
J. vasc. bras ; 20: e20200191, 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1279371

RESUMEN

Abstract Background The contrast power injector (CPI) is the gold standard method for injecting contrast with the pressure and flow needed to generate a satisfactory images during endovascular procedures, but it is an expensive tool, narrowing its wide-scale applications. One alternative is the manual injection (MI) method, but this does not generate the pressure required for adequate visualization of anatomy. It is therefore imperative to create an alternative low-cost method that is capable of producing high quality images. Objectives To compare the injection parameters of a new mechanical device (Hand-Crank) created in a university hospital with the MI method and with the contrast power injector's ideal values. Methods A circulation phantom was constructed to simulate the pressure in the aorto-iliac territory and the injection parameters of the two methods were compared in a laboratory setting. Student's t test and the Mann-Whitney test were used for statistical analysis. Three vascular surgery residents (the authors) performed the injections (each performed 9 tests using conventional manual injection and 9 tests using the Hand-Crank, totaling 54 injections). Results There were statistical differences between the two methods (p<0.05) in total volume injected until maximum pressure was attained, pressure variation, maximum pressure, total injection time, and time to reach the maximum pressure. Conclusions The Hand-Crank can achieve higher maximum pressure, higher average flow, and lower injection time than the manual method. It is a simple, low-cost, and effective tool for enhancing injection parameters in an experimental setup. It could help to produce higher quality images in a clinical scenario.


Resumo Contexto A bomba injetora é o método padrão-ouro para a injeção de contraste em aortografias. Entretanto, é uma ferramenta de alto custo, o que limita o seu uso. A injeção manual surge como alternativa, mas a pressão gerada com esse método é baixa, e, por isso, a qualidade das imagens não é usualmente satisfatória. Assim, a criação de um método de baixo custo capaz de gerar imagens de qualidade é imperativo. Objetivos Comparar os parâmetros de injeção de um novo dispositivo mecânico (manivela articulada) criado em um hospital universitário com os parâmetros da injeção manual e com os valores ideais da bomba injetora. Métodos Um simulador do território aórtico foi construído, e parâmetros de injeção entre os diferentes métodos em um cenário laboratorial controlado foram analisados. O teste t de Student e o teste de Mann-Whitney foram usados para análise estatística. Três residentes de Cirurgia Vascular realizaram os testes (nove usando o novo dispositivo, e nove usando a injeção manual, totalizando 54 injeções). Resultados Houve diferença estatisticamente significativa (p < 0,05) entre os dois métodos, considerando os parâmetros: variação de pressão, pressão máxima, tempo de injeção, tempo até a pressão máxima e volume até a pressão máxima. Conclusões A manivela articulada atingiu níveis superiores de pressão e de velocidade de injeção, com menor tempo de injeção do que a injeção manual. É um dispositivo simples, de baixo custo e com resultados comparáveis à bomba injetora, o que sugere seu uso potencial na geração de imagens satisfatórias em aortografias.


Asunto(s)
Bombas de Infusión , Radiología Intervencionista/instrumentación , Medios de Contraste/administración & dosificación , Procedimientos Quirúrgicos Vasculares , Angiografía/instrumentación , Tecnología de Bajo Costo , Costos y Análisis de Costo , Procedimientos Endovasculares , Inyecciones/instrumentación
10.
Phys Med Biol ; 65(22): 225028, 2020 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-33231200

RESUMEN

This work compared the impact of x-ray tube performance and automatic dose rate control (ADRC) parameter selection on system imaging efficiency of two Siemens angiography systems: a Siemens Megalix x-ray tube installed on an Artis Zee system (denoted 'MEGALIX') and a newer generation Gigalix x-ray tube installed on an Artis Q (denoted 'GIGALIX'). A method was used that accounted for two potential sources of bias in this comparison: differences in radiation output between the x-ray tubes and differences between the x-ray detectors on the two systems. First, ADRC x-ray factors (tube voltage, tube current, pulse length, focus size, spectral prefilter) and radiation output were recorded as a function of poly(methyl) methacrylate (PMMA) thickness on the MEGALIX unit. These factors were then applied manually on the GIGALIX system and incident air kerma rate (IAKR) and signal difference to noise ratio (SDNR) were measured. Second, the ADRC on the GIGALIX system was used to give the x-ray factors and both IAKR and SDNR relevant to the GIGALIX based system directly. This method enabled the SDNR to be measured from images acquired on the same x-ray detector. SDNR and IAKR were measured on both systems using a PMMA phantom covering thicknesses from 6 cm to 40 cm. A small 0.3 mm iron insert was used to measure SDNR, which was then multiplied by modulation transfer function based weighting factors for focal spot blurring and motion blurring. These factors were evaluated for an object motion of 25 mm s-1 and at a spatial frequency of 1.4 mm-1 in the object plane, relevant to interventional cardiology, giving a spatial frequency dependent SDNR(u). In the second phase of the study, a technical figure of merit (FOM) was used to express imaging performance of both systems, calculated as SDNR2(u)/IAKR. Averaged over all phantom thicknesses, the FOM of the GIGALIX-based system was 42% and 73% higher compared to that of the MEGALIX based system, for fluoroscopy and acquisition mode respectively. The results indicate that increased x-ray tube power and smaller foci can improve overall system efficiency and reduce doses.


Asunto(s)
Angiografía/instrumentación , Aire , Humanos , Fantasmas de Imagen , Polimetil Metacrilato , Dosis de Radiación , Relación Señal-Ruido , Rayos X
11.
Sci Rep ; 10(1): 17247, 2020 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-33057029

RESUMEN

Magnetic Particle Imaging (MPI) is a new imaging modality, which maps the distribution of magnetic nanoparticles (MNP) in 3D with high temporal resolution. It thus may be suited for cardiovascular imaging. Its sensitivity and spatial resolution critically depend on the magnetic properties of MNP. Therefore, we used novel multicore nanoparticles (MCP 3) for in-vivo MPI in rats and analyzed dose requirements, sensitivity and detail resolution. 8 rats were examined using a preclinical MPI scanner (Bruker Biospin GmbH, Germany) equipped with a separate receive coil. MCP 3 and Resovist were administered intravenously (i.v.) into the rats' tail veins at doses of 0.1, 0.05 and 0.025 mmol Fe/kg followed by serial MPI acquisition with a temporal resolution of 46 volumes per second. Based on a qualitative visual scoring system MCP 3-MPI images showed a significantly (P ≤ 0.05) higher image quality than Resovist-MPI images. Morphological features such as vessel lumen diameters (DL) of the inferior vena cava (IVC) and abdominal aorta (AA) could be assessed along a 2-cm segment in mesenteric area only after administration of MCP 3 at dosages of 0.1, 0.05 mmol Fe/kg. The mean DL ± SD estimated was 2.7 ± 0.6 mm for IVC and 2.4 ± 0.7 mm for AA. Evaluation of DL of the IVC and AA was not possible in Resovist-MPI images. Our results show, that MCP 3 provide better image quality at a lower dosage than Resovist. MCP 3-MPI with a clinically acceptable dose of 0.05 mmol Fe/kg increased the visibility of vessel lumens compared to Resovist-based MPI towards possible detection of vascular abnormalities such as stenosis or aneurysms, in vivo.


Asunto(s)
Angiografía/métodos , Aorta/diagnóstico por imagen , Vena Cava Inferior/diagnóstico por imagen , Angiografía/instrumentación , Animales , Nanopartículas Magnéticas de Óxido de Hierro/química , Masculino , Ratas , Ratas Sprague-Dawley
12.
Artículo en Inglés | MEDLINE | ID: mdl-32746179

RESUMEN

This study demonstrates, in detail, the potential of using capacitive micromachined ultrasonic transducers (CMUTs) for acoustic angiography of the microvasculature. It is known that when ultrasound contrast agents (microbubbles) are excited with moderate acoustic pressure around their resonance (2-4 MHz), they produce higher order harmonics (greater than third harmonic) due to their nonlinear behavior. To date, the fundamental challenge has been the availability of a transducer that can generate the transmit signals to excite the microbubbles at low frequencies and, in the same cycle, confocally detect harmonics in the higher frequencies. We present a novel device structure and dual-mode operation of a CMUT that operates with a center frequency of 4.3 MHz and 150% bandwidth in the conventional mode for transmitting and a center frequency of 9.8 MHz and a 125.5% bandwidth in collapse mode for receiving. Output pressure of 1.7 MPapp is achieved on the surface of a single unfocused transducer. The mechanical index at the transducer surface is 0.56. FEM simulations are performed first to show the functionality of the proposed device, and then, the device fabrication is described in detail. Finally, we experimentally demonstrate the ability to detect the microbubble signals with good contrast, and the background reflection is adequately suppressed, indicating the feasibility of the presented approach for acoustic angiography.


Asunto(s)
Angiografía , Transductores , Ultrasonografía , Angiografía/instrumentación , Angiografía/métodos , Medios de Contraste , Diseño de Equipo , Análisis de Elementos Finitos , Microburbujas , Fantasmas de Imagen , Ultrasonografía/instrumentación , Ultrasonografía/métodos
13.
Nat Commun ; 11(1): 3851, 2020 07 31.
Artículo en Inglés | MEDLINE | ID: mdl-32737314

RESUMEN

Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries' microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases. Here, we present a neurovascular high-frequency optical coherence tomography (HF-OCT) system, including an imaging console and an endoscopic probe designed to rapidly acquire volumetric microscopy data at a resolution approaching 10 microns in tortuous cerebrovascular anatomies. Using a combination of in vitro, ex vivo, and in vivo models, the feasibility of HF-OCT for cerebrovascular imaging was demonstrated.


Asunto(s)
Arteria Basilar/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Arterias Cerebrales/diagnóstico por imagen , Microscopía/métodos , Tomografía de Coherencia Óptica/métodos , Arteria Vertebral/diagnóstico por imagen , Angiografía/instrumentación , Angiografía/métodos , Animales , Cadáver , Circulación Cerebrovascular/fisiología , Humanos , Microscopía/instrumentación , Porcinos , Tomografía de Coherencia Óptica/instrumentación
14.
PLoS One ; 15(6): e0234664, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32544179

RESUMEN

PURPOSE: To compare quantitative changes in macular parameters in diabetic patients detected by two optical coherence tomography angiography (OCTA) instruments. METHODS: 80 phakic eyes were classified as no diabetes, diabetes without diabetic retinopathy (DR), mild non-proliferative diabetic retinopathy (NPDR), and severe NPDR or proliferative DR (PDR). OCTA was performed using devices from two manufacturers (Zeiss and Heidelberg). Superficial and deeper vascular skeleton density (SVSD, DVSD), superficial and deeper vessel area density (SVAD, DVAD), choriocapillaris flow voids (CCFV), and choroidal flow voids (CFV) were calculated. Inter-device comparisons were performed using the size comparison index (SCI) and the discrepancy index (DI). RESULTS: The two devices were inconsistent in SVSD, DVSD, DVAD, CCFV and CFV parameters (all P < 0.05). In addition, the SCI was positive for DVAD (all P < 0.001) and negative for SVSD, DVSD, CCFV and CFV in all groups (all P <0.001), except for DVSD in severe NPDR or PDR. The discrepancy index was not significantly different among groups for SVD, SPD, DVD, DPD and CFV (all P> 0.05). The mean DI of CCFV was statistically different between the four groups (P < 0.001). CONCLUSIONS: The two instruments were largely inconsistent in the measurement of macular parameters relevant to DR. The choice of imaging device can impact OCTA analytics and should be taken into account when drawing conclusions about DR-related changes.


Asunto(s)
Angiografía , Diabetes Mellitus/fisiopatología , Retinopatía Diabética/diagnóstico por imagen , Ojo/diagnóstico por imagen , Tomografía de Coherencia Óptica/instrumentación , Angiografía/instrumentación , Angiografía/métodos , Angiografía/normas , Estudios de Casos y Controles , Complicaciones de la Diabetes/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/normas
15.
Opt Lett ; 45(9): 2522-2525, 2020 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-32356806

RESUMEN

Optoacoustic microscopy (OAM) can image intrinsic optical absorption contrast at depths of several millimeters where state-of-the-art optical microscopy techniques fail due to intense light scattering in living tissues. Yet, wide adoption of OAM in biology and medicine is hindered by slow image acquisition speed, small field of view (FOV), and/or lack of spectral differentiation capacity of common system implementations. We report on a rapid acquisition functional optoacoustic micro-angiography approach that employs a burst-mode laser triggering scheme to simultaneously acquire multi-wavelength 3D images over an extended FOV covering ${50}\;{\rm mm} \times {50}\;{\rm mm}$50mm×50mm in a single mechanical overfly scan, attaining 28 µm and 14 µm resolution in lateral and axial dimensions, respectively. Owing to an ultrawideband low-noise design featuring a spherically focused polyvinylidene difluoride transducer, we demonstrate imaging of human skin and underlying vasculature at up to 3.8 mm depth when using per-pulse laser energies of only 25 µJ without employing signal averaging. Overall, the developed system greatly enhances performance and usability of OAM for dermatologic and micro-angiographic studies.


Asunto(s)
Angiografía/métodos , Técnicas Fotoacústicas/métodos , Angiografía/instrumentación , Mano/diagnóstico por imagen , Humanos , Imagenología Tridimensional , Técnicas Fotoacústicas/instrumentación
16.
Nat Commun ; 11(1): 1868, 2020 04 20.
Artículo en Inglés | MEDLINE | ID: mdl-32313067

RESUMEN

In today's clinics, a cell-resolution view of the cornea can be achieved only with a confocal microscope (IVCM) in contact with the eye. Here, we present a common-path full-field/spectral-domain OCT microscope (FF/SD OCT), which enables cell-detail imaging of the entire ocular surface in humans (central and peripheral cornea, limbus, sclera, tear film) without contact and in real-time. Real-time performance is achieved through rapid axial eye tracking and simultaneous defocusing correction. Images contain cells and nerves, which can be quantified over a millimetric field-of-view, beyond the capability of IVCM and conventional OCT. In the limbus, palisades of Vogt, vessels, and blood flow can be resolved with high contrast without contrast agent injection. The fast imaging speed of 275 frames/s (0.6 billion pixels/s) allows direct monitoring of blood flow dynamics, enabling creation of high-resolution velocity maps. Tear flow velocity and evaporation time can be measured without fluorescein administration.


Asunto(s)
Angiografía/instrumentación , Angiografía/métodos , Córnea/diagnóstico por imagen , Tomografía de Coherencia Óptica/instrumentación , Tomografía de Coherencia Óptica/métodos , Adulto , Ingeniería Biomédica/instrumentación , Ingeniería Biomédica/métodos , Velocidad del Flujo Sanguíneo , Córnea/patología , Diseño de Equipo , Femenino , Humanos , Limbo de la Córnea/diagnóstico por imagen , Limbo de la Córnea/patología , Masculino , Microscopía/métodos , Imagen Óptica/instrumentación , Imagen Óptica/métodos , Programas Informáticos , Adulto Joven
17.
Medicine (Baltimore) ; 99(15): e19630, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32282712

RESUMEN

To investigate computed tomography and angiography findings and clinical outcomes after transcatheter arterial embolization for acute upper gastrointestinal bleeding from advanced gastric cancers.From January 2005 to December 2014, 58 patients with pathologically proven gastric cancer were treated at our institution with transcatheter arterial embolization due to acute upper gastrointestinal bleeding recalcitrant to endoscopic treatment. The electronic medical records for each patient were reviewed for clinical presentation, endoscopy history, computed tomography and angiographic findings, blood transfusion requirements, and follow-up results.Angiography findings were positive in 13 patients (22.4%): contrast extravasation was found in 9 patients and pseudoaneurysm in 4 patients. All patients with positive angiograms underwent selective embolization treatment. Those with negative angiography findings underwent empirical embolization. Gelfoam, n-butyl cyanoacrylate, coils, or a combination of these were used as embolic agents. The overall clinical success rate was 72.4% (42/58), and the success rate for patients with positive angiography was 53.8% (7/13). The median survival was 97.5 days (range, 7-1415 days), and the 1-month survival rate was 89.6% (52/58). The 1-month survival rate of the clinical success group was 95.2% (40/42), which was significantly higher than that of the clinical failure group (P = .04). The clinical success group also required significantly fewer transfusions (2.43 units, range 0-24 units) (P = .02).Transcatheter arterial embolization is a highly effective treatment for advanced gastric cancer with active bleeding. It should be considered as an additional treatment, especially when endoscopic or surgical treatment fails or when these approaches are difficult.


Asunto(s)
Embolización Terapéutica/métodos , Hemorragia Gastrointestinal/terapia , Neoplasias Gástricas/complicaciones , Tomografía Computarizada por Rayos X/métodos , Anciano , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/epidemiología , Angiografía/instrumentación , Embolización Terapéutica/tendencias , Enbucrilato/uso terapéutico , Extravasación de Materiales Terapéuticos y Diagnósticos/diagnóstico por imagen , Extravasación de Materiales Terapéuticos y Diagnósticos/epidemiología , Femenino , Hemorragia Gastrointestinal/diagnóstico por imagen , Hemorragia Gastrointestinal/epidemiología , Esponja de Gelatina Absorbible/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Estómago/irrigación sanguínea , Estómago/patología , Neoplasias Gástricas/patología , Tasa de Supervivencia , Resultado del Tratamiento
19.
Phys Med ; 71: 3-6, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32056781

RESUMEN

Cone beam technology is becoming more prominent in Radiology. In our hospital we have an extremity CT, an O-arm and a number of C-arms offering 3D capabilities. Each of these modalities use cone beam CT (CBCT) technology to image the area of interest in one single rotation. Traditional CTDI metrics for radiation dosimetry in CT depend on narrow beam geometry. The relevance of the CTDI as a dose indicator for cone beam scanning is contentious due to underestimation of dose lying outside the standard 100 mm chamber length and CTDI phantoms being of insufficient length. In an attempt to better quantify dose from cone beam scanning, alternative methodologies have been developed which attempt to counter the limitations of CTDI methodologies. In this comparison study we utilised the CBCT methodologies outlined in (i) IAEA Report 5, (ii) EFOMP's protocol on QC in CBCT and (iii) conventional CTDI measurement and tested them on various CBCT systems used in Radiology. These methods were chosen as they use equipment that is typically available to a diagnostic imaging physicist. We determine that the EFOMP protocol and the conventional CTDI method produce the best estimate of the radiation output for quality control purposes. Our conclusion is that the EFOMP protocol is the fastest and easiest method to measure a CBCT metric but it is not always accessible. For the systems in our hospital we will adopt the EFOMP protocol for open systems (C-arms) and perform CTDIVol measurements using conventional techniques on enclosed systems (O-arm and extremity CT).


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Tomografía Computarizada de Haz Cónico/métodos , Radiología/métodos , Radiometría/métodos , Angiografía/instrumentación , Angiografía/métodos , Humanos , Imagenología Tridimensional , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Control de Calidad , Dosis de Radiación , Cirugía Asistida por Computador , Rayos X
20.
Plast Reconstr Surg ; 145(2): 407e-411e, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31985656

RESUMEN

The utility of nitroglycerin is well established in coronary angiography but less so in other surgical fields. In this study, the authors investigated the utility of preoperative computed tomographic angiography after sublingual nitroglycerin followed by three-dimensional visualization for selecting suitable perforators in planning the free anterolateral thigh flap. The authors performed preoperative computed tomographic angiography following sublingual nitroglycerin (after screening for contraindications) in patients for whom reconstructive surgery with the free anterolateral thigh flap was planned. Data were reconstructed three-dimensionally, mapping location and course of source arteries and perforators. Suitable perforators were selected, and flap design was planned. The characteristics of perforators were analyzed statistically. Of 14 patients for whom surgery was planned, two had contraindications to nitroglycerin and underwent computed tomographic angiography alone. Nitroglycerin allowed for the visualization of more peripheral branches. The Hounsfield units at the deep fascia of perforators selected for surgery were significantly higher than for those not selected (p = 0.003). The distance from the intermuscular septum to the selected perforators was significantly shorter than the distance to nonselected perforators (p = 0.017). There were no adverse events, and all flaps survived. Sublingual nitroglycerin before computed tomographic angiography was safe and increased the visibility of perforators, enabling preoperative planning of flap design based on the three-dimensionally-reconstructed image. The authors highly recommend this procedure. CLINICAL QUESTION/LEVEL OF EVIDENCE:: Diagnostic, IV.


Asunto(s)
Angiografía/instrumentación , Arterias/diagnóstico por imagen , Nitroglicerina/administración & dosificación , Procedimientos de Cirugía Plástica/métodos , Traumatismos de los Tejidos Blandos/cirugía , Colgajos Quirúrgicos , Muslo/cirugía , Tomografía Computarizada por Rayos X/métodos , Adulto , Angiografía/métodos , Niño , Preescolar , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS