Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
In Vivo ; 37(3): 963-971, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37103087

RESUMEN

The aim of this narrative review of the literature was to collect and analyze the results of the published preclinical studies on stereotactic arrhythmia radioablation (STAR) in the treatment of refractory cardiac arrhythmias. A literature search was conducted on PubMed using the following terms: ("stereotactic" OR "SBRT" OR "SABR" OR "radioablation" OR "radiosurgery") AND ("arrhythmia" OR "tachycardia"). Preclinical and pathological reports published in English without time limit, comprising studies of STAR in animal models and histological analyzes of explanted animal and human hearts were included. The analyzed studies confirm that doses lower than 25 Gy seem to produce sub-optimal therapeutic results whereas doses >35 Gy are less safe in terms of radiation-induced toxicity. However, long-term results (>1 year) are still missing and reporting outcomes based on low dose irradiation (≤15 Gy). Finally, STAR proved to be an effective therapy in the analyzed studies despite the irradiation of rather different cardiac targets. Therefore, additional studies are needed to: 1) compare the outcomes of STAR at doses of 25 Gy versus 30 Gy; 2) evaluate the long-term results (>1 year) in animal models irradiated at doses similar to those used in the clinic; 3) define the optimal target.


Asunto(s)
Arritmias Cardíacas , Radiocirugia , Animales , Humanos , Arritmias Cardíacas/etiología , Arritmias Cardíacas/radioterapia , Radiocirugia/efectos adversos , Radiocirugia/métodos , Corazón , Modelos Animales , Factores de Tiempo
3.
J Am Heart Assoc ; 10(6): e019072, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33660526

RESUMEN

Background Noninvasive cardiac radioablation is employed to treat ventricular arrhythmia. However, myocardial changes leading to early-period antiarrhythmic effects induced by high-dose irradiation are unknown. This study investigated dose-responsive histologic, ultrastructural, and functional changes within 1 month after irradiation in rat heart. Methods and Results Whole hearts of wild-type Lewis rats (N=95) were irradiated with single fraction 20, 25, 30, 40, or 50 Gy and explanted at 1 day or 1, 2, 3, or 4 weeks' postirradiation. Microscopic pathologic changes of cardiac structures by light microscope with immunohistopathologic staining, ultrastructure by electron microscopy, and functional evaluation by ECG and echocardiography were studied. Despite high-dose irradiation, no myocardial necrosis and apoptosis were observed. Intercalated discs were widened and disrupted, forming uneven and twisted junctions between adjacent myocytes. Diffuse vacuolization peaked at 3 weeks, suggesting irradiation dose-responsiveness, which was correlated with interstitial and intracellular edema. CD68 immunostaining accompanying vacuolization suggested mononuclear cell infiltration. These changes were prominent in working myocardium but not cardiac conduction tissue. Intracardiac conduction represented by PR and QTc intervals on ECG was delayed compared with baseline measurements. ST segment was initially depressed and gradually elevated. Ventricular chamber dimensions and function remained intact without pericardial effusion. Conclusions Mononuclear cell-related intracellular and extracellular edema with diffuse vacuolization and intercalated disc widening were observed within 1 month after high-dose irradiation. ECG indicated intracardiac conduction delay with prominent ST-segment changes. These observations suggest that early antiarrhythmic effects after cardiac radioablation result from conduction disturbances and membrane potential alterations without necrosis.


Asunto(s)
Arritmias Cardíacas/radioterapia , Ecocardiografía , Electrocardiografía , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/ultraestructura , Miocardio/ultraestructura , Radiocirugia/métodos , Animales , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Relación Dosis-Respuesta en la Radiación , Estudios de Seguimiento , Ventrículos Cardíacos/efectos de la radiación , Masculino , Microscopía Electrónica , Ratas , Ratas Endogámicas Lew , Factores de Tiempo
4.
Cancer Radiother ; 25(4): 373-379, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33589330

RESUMEN

Stereotactic body radiotherapy (SBRT) is a high precision technique that is commonly used for malignant lesions in lung, liver, pancreas and spine. Recent reports suggest promise in use of SBRT as a tool in atrial and ventricular cardiac arrhythmias. The present systematic review deals with the use of SBRT technology for this novel indication. A PubMed search was done for articles published between 1990 and 2020. All original articles, case reports, case series of treated patients were included in the analyses. Out of the 55 articles in PubMed search, our search found 1 phase I/II clinical case series, 3 clinical case reports, 3 animal studies and 4 dosimetric studies related to cardiac SBRT for arrythmias. All studies used a uniform cardiac dose of 25Gy. The available preclinical, dosimetric and clinical studies have suggested that SBRT for cardiac arrhythmias could become a potential alternative in suitable patients. Cardiac and radiation oncology community await further data and experience in this modality, including safety and outcomes.


Asunto(s)
Arritmias Cardíacas/radioterapia , Radiocirugia/métodos , Animales , Fibrilación Atrial/radioterapia , Perros , Humanos , Dosificación Radioterapéutica , Porcinos , Taquicardia Ventricular/radioterapia
5.
Radiol Med ; 126(1): 155-162, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32405924

RESUMEN

AIM: Stereotactic ablative radiation therapy (SABR) is used in non-oncologic indications, recently even for cardiac arrhythmias. Thus, aim of this analysis is to review preclinical, early clinical evidences and future direction of the latter new treatment approach. METHOD: A collection of available data regarding SABR and cardiac arrhythmias was made, by Pubmed research and 2 independent researchers, including preclinical and clinical data. A review of ongoing trials was conducted on ClinicalTrials.gov. RESULTS: Preclinical research conducted in animal models showed that a safe and effective noninvasive treatment approach for cardiac arrhythmias could be represented by SABR with a median time of response around 2-3 months. The treatment dose plays a crucial role: the atrioventricular node would seem more radiosensitive than the other cardiac electric zones. Clinical data, such as published case series, case reports and early prospective studies, have already suggested the feasibility, efficacy and safety of SABR (25 Gy in one session) for refractory ventricular arrhythmias. CONCLUSION: Considering the ongoing trials of SABR and new technological improvements in radiotherapy (e.g. hybrid magnetic resonance) and in arrhythmias noninvasive mapping systems, the future analyses will improve the reliability of those preliminary results.


Asunto(s)
Arritmias Cardíacas/radioterapia , Radiocirugia/métodos , Humanos
6.
Int J Radiat Oncol Biol Phys ; 109(3): 783-800, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33160007

RESUMEN

PURPOSE: Cardiac radioablation (CR), a new treatment for cardiac arrhythmias such as ventricular tachycardia and atrial fibrillation, has had promising clinical outcomes to date. There is consequent desire for rapid clinical adoption. However, CR presents unique challenges to radiation therapy, and it is paramount that clinical adoption be performed safely and effectively. Recent reviews comprehensively detail patient selection, clinical history, treatment outcomes, and treatment toxicities but only briefly mention the technical aspects of CR. To address this knowledge gap, this review collates currently available knowledge regarding CR technology choice and procedural details to help inform and guide clinics considering implementing their own CR program, to aid technique standardization, and to highlight areas that require further development or verification. METHODS AND MATERIALS: Original preclinical and clinical scientific articles that sufficiently detailed CR technical aspects, including pretreatment electrophysiology and imaging, motion analysis and management techniques, treatment planning, and/or treatment delivery, were identified within a comprehensive literature search. RESULTS: Nineteen preclinical and 18 clinical scientific articles sufficiently detailed the technical aspects of CR treatment deliveries on live subjects. The technical aspects of these scientific articles were diverse: Preclinical treatments have been performed with brachytherapy, photons, protons, and carbon ions, and clinical treatments have been performed with photons using conventional, robotic, and magnetic resonance imaging guided systems. Other technical aspects demonstrated similar variability. CONCLUSIONS: This review summarizes the technical aspects and procedural details of preclinical and clinical CR treatment deliveries and highlights the complexity and current variability of CR. There is need for standardized procedural reporting to aid multicenter and multiplatform evaluation and potential for significant technological improvements in imaging, planning, delivery, and monitoring to maximize the clinical outcomes for selected patients with arrhythmia.


Asunto(s)
Arritmias Cardíacas/radioterapia , Radiocirugia/métodos , Animales , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/fisiopatología , Fibrilación Atrial/radioterapia , Cicatriz/diagnóstico por imagen , Perros , Electrocardiografía , Corazón/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética Intervencional , Movimientos de los Órganos , Órganos en Riesgo , Conejos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia Guiada por Imagen/métodos , Porcinos , Porcinos Enanos , Taquicardia Ventricular/radioterapia , Resultado del Tratamiento
7.
Biomed Res Int ; 2019: 4217076, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30984780

RESUMEN

PURPOSE: 3D nonfluoroscopic mapping systems (NMSs) are generally used in the catheter ablation (CA) of complex ventricular and atrial arrhythmias. The aim of this study was to evaluate the efficacy, safety, and long-term effect of the extended, routine use of NMSs for CA. METHODS: Our study involved 1028 patients who underwent CA procedures from 2007 to 2016. Initially, CA procedures were performed mainly with the aid of fluoroscopy. From October 2008, NMSs were used for all procedures. RESULTS: The median fluoroscopy time of the overall CA procedures fell by 71%: from 29.2 min in 2007 to 8.4 min in 2016. Over the same period, total X-ray exposure decreased by 65%: from 58.18 Gy⁎cm2 to 20.19 Gy⁎cm2. This reduction was achieved without prolonging the total procedure time. In AF CA procedures, the median fluoroscopy time fell by 85%, with an 86% reduction in total X-ray exposure. In SVT CA procedures, the median fluoroscopy time fell by 93%, with a 92% reduction in total X-ray exposure. At the end of the follow-up period, the estimated probability of disease-free survival was 67.7% at 12 months for AF CA procedures and 97.2% at 3 months for SVT CA, without any statistically significant difference between years. CONCLUSIONS: Our study shows the feasibility of using NMSs as the main imaging modality to guide CA. The extended, routine use of NMSs dramatically reduces radiation exposure, with only slight fluctuations due to the process of acquiring experience on the part of untrained operators, without affecting disease-free survival.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Fibrilación Atrial/radioterapia , Ablación por Catéter/efectos adversos , Neoplasias Inducidas por Radiación/diagnóstico por imagen , Anciano , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/patología , Arritmias Cardíacas/radioterapia , Fibrilación Atrial/complicaciones , Fibrilación Atrial/patología , Femenino , Humanos , Imagenología Tridimensional/métodos , Persona de Mediana Edad , Neoplasias Inducidas por Radiación/patología , Neoplasias Inducidas por Radiación/prevención & control , Exposición a la Radiación/efectos adversos , Cirugía Asistida por Computador , Rayos X/efectos adversos
8.
Sci Rep ; 9(1): 5000, 2019 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-30899027

RESUMEN

Noninvasive X-ray stereotactic treatment is considered a promising alternative to catheter ablation in patients affected by severe heart arrhythmia. High-energy heavy ions can deliver high radiation doses in small targets with reduced damage to the normal tissue compared to conventional X-rays. For this reason, charged particle therapy, widely used in oncology, can be a powerful tool for radiosurgery in cardiac diseases. We have recently performed a feasibility study in a swine model using high doses of high-energy C-ions to target specific cardiac structures. Interruption of cardiac conduction was observed in some animals. Here we report the biological effects measured in the pig heart tissue of the same animals six months after the treatment. Immunohistological analysis of the target tissue showed (1.) long-lasting vascular damage, i.e. persistent hemorrhage, loss of microvessels, and occurrence of siderophages, (2.) fibrosis and (3.) loss of polarity of targeted cardiomyocytes and wavy fibers with vacuolization. We conclude that the observed physiological changes in heart function are produced by radiation-induced fibrosis and cardiomyocyte functional inactivation. No effects were observed in the normal tissue traversed by the particle beam, suggesting that charged particles have the potential to produce ablation of specific heart targets with minimal side effects.


Asunto(s)
Arritmias Cardíacas/radioterapia , Miocardio/patología , Miocitos Cardíacos/efectos de la radiación , Terapia por Rayos X/efectos adversos , Animales , Arritmias Cardíacas/patología , Ablación por Catéter/efectos adversos , Corazón/efectos de la radiación , Frecuencia Cardíaca/efectos de la radiación , Iones Pesados/efectos adversos , Humanos , Miocitos Cardíacos/patología , Radiación no Ionizante/efectos adversos , Radiocirugia/efectos adversos , Técnicas Estereotáxicas/tendencias , Porcinos
9.
Med Phys ; 45(11): e1024-e1035, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30421810

RESUMEN

Cardiac arrhythmias are a major health burden, associated with reduced quality of life and substantial morbidity and mortality. Current therapy includes moderately effective medication and catheter-based ablation of arrhythmogenic substrates in the heart. Catheter interventions frequently have to be repeated due to recurrent arrhythmia, can have rare but severe side-effects and are less suited especially for potentially lethal left ventricular tachycardia. Noninvasive alternatives are therefore warranted. Photon and ion beam radiotherapy has been studied in animal models and first patient cases have been reported using photons. Ion beams might offer the possibility to greatly reduce dose to surrounding healthy tissue, including critical cardiac substructures. Based on a recently conducted animal study, we report advantages and disadvantages of 4D-ion beam therapy, and strategies necessary for a clinical transition. Motion management of both respiration and heartbeat are discussed, as well as range uncertainty resulting from both regular motion and interfractional anatomic changes. Image guidance both in 3D and 4D has to be employed for a safe irradiation, but also population-based data on motion variability and time behavior of interfractional changes are necessary. Range verification could play a crucial role at least during development of clinical protocols. For clinical realization, it appears necessary to suppress or conformally mitigate the large respiratory motion to avoid normal tissue complications. Cardiac motion has to be incorporated into treatment planning, either through adequate range-considering internal margins or through more conformal strategies such as ECG-based gating or even 4D-optimization. The latter strategies would necessitate online 4D image guidance.


Asunto(s)
Técnicas de Ablación/métodos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/radioterapia , Diagnóstico por Imagen , Humanos , Movimiento , Posicionamiento del Paciente , Planificación de la Radioterapia Asistida por Computador
10.
Curr Cardiol Rep ; 19(9): 79, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28752279

RESUMEN

PURPOSE OF REVIEW: Stereotactic radioablation is a commonly utilized technology to noninvasively treat solid tumors with precision and efficacy. Using a robotic arm mounted delivery system, multiple low-dose ionizing radiation beams are delivered from multiple angles, concentrating ablative energy at the target tissue. Recently, this technology has been evaluated for treatment of cardiac arrhythmias. This review will present the basic underlying principles, proof-of-principle studies, and clinical experience with stereotactic arrhythmia radioablation. RECENT FINDINGS: Most recently, stereotactic radioablation has been used to safely and effectively treat a limited number of patients with malignant arrhythmias, including ventricular tachycardia (VT) and atrial fibrillation (AF). Treatment protocols, outcomes, ongoing studies, and future directions will be discussed. Stereotactic radioablation is a well-established technology that has been shown to be a safe and effective therapy for patients with drug-refractory cardiac arrhythmias, including VT and AF. Further clinical evaluation to define safety and efficacy in larger populations of patients is needed.


Asunto(s)
Arritmias Cardíacas/radioterapia , Radiocirugia , Fibrilación Atrial/radioterapia , Ablación por Catéter , Protocolos Clínicos , Humanos , Taquicardia Ventricular/radioterapia
11.
Sci Rep ; 6: 38895, 2016 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-27996023

RESUMEN

High-energy ion beams are successfully used in cancer therapy and precisely deliver high doses of ionizing radiation to small deep-seated target volumes. A similar noninvasive treatment modality for cardiac arrhythmias was tested here. This study used high-energy carbon ions for ablation of cardiac tissue in pigs. Doses of 25, 40, and 55 Gy were applied in forced-breath-hold to the atrioventricular junction, left atrial pulmonary vein junction, and freewall left ventricle of intact animals. Procedural success was tracked by (1.) in-beam positron-emission tomography (PET) imaging; (2.) intracardiac voltage mapping with visible lesion on ultrasound; (3.) lesion outcomes in pathohistolgy. High doses (40-55 Gy) caused slowing and interruption of cardiac impulse propagation. Target fibrosis was the main mediator of the ablation effect. In irradiated tissue, apoptosis was present after 3, but not 6 months. Our study shows feasibility to use high-energy ion beams for creation of cardiac lesions that chronically interrupt cardiac conduction.


Asunto(s)
Arritmias Cardíacas/radioterapia , Radioterapia de Alta Energía/métodos , Animales , Apoptosis/efectos de la radiación , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/patología , Relación Dosis-Respuesta en la Radiación , Femenino , Masculino , Miocardio/metabolismo , Miocardio/patología , Tomografía de Emisión de Positrones , Sus scrofa
12.
Intern Emerg Med ; 9(8): 853-60, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24950960

RESUMEN

Cryoablation (CA) emerged as an alternative procedure to radiofrequency (RF). The aim of this study was to compare haemostatic system alterations in patients undergoing RF or CA for atrioventricular nodal reentrant tachycardia ablation. von Willebrand factor (vWF), spontaneous whole blood platelet aggregation, prothrombin fragment F1 + 2 (F1 + 2), thrombin-antithrombin complex (TAT), plasminogen activator inhibitor type-1 (PAI-1), and clot lysis time (CLT) were determined in 48 patients (27 CA; 21 RF; 19M/29F, mean age 49.6 ± 17.6 years). Blood samples were obtained before the procedure (T0), immediately after (T1), and 24 h later (T2). At T1 both procedures were associated with a significant increase in levels of the endothelial activation marker vWF. At T2 vWF levels were lower in CA than in RF group. No changes in whole blood platelet aggregation before and after ablation procedures were observed. At T1 both groups determined an increase in blood clotting activation markers, F1 + 2, TAT, and DD. At T2 F1 + 2, TAT and DD levels were similar to baseline values. The comparison between RF and CA showed no significant differences in F1 + 2 and TAT levels, whereas at T1 DD levels were higher in CA group than in RF group. Both procedures induced a significant decrease in CLT, whereas no changes in PAI-1 levels were found. There were no significant differences in CLT and PAI-1 levels. The fibrinolytic efficiency analysis showed that at T1 DD/TAT and DD/F1 + 2 ratios were lower in RF group and remained lower in RF than in CA group at T2. CA procedure may be associated with a lower degree of endothelial damage and with a higher fibrinolytic capacity respect to RF.


Asunto(s)
Coagulación Sanguínea/fisiología , Ablación por Catéter/normas , Criocirugía/normas , Trombosis/radioterapia , Resultado del Tratamiento , Adulto , Anciano , Arritmias Cardíacas/radioterapia , Femenino , Humanos , Masculino , Persona de Mediana Edad
14.
J Interv Card Electrophysiol ; 19(3): 179-85, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17823861

RESUMEN

INTRODUCTION: Radiofrequency (RF) catheter ablation has not been widely undertaken in elderly patients. The aim of our study was to compare the success rate of radiofrequency ablation and the incidence of severe procedural complications in young-adult and elderly patients. METHODS: We enrolled all patients undergoing radiofrequency catheter ablation procedures for supraventricular and ventricular arrhythmias at our Cardiology Department from January 2000 to December 2005. The patients were divided into two groups according to age: patients aged <70 years (group A) and those aged >or=70 years (group B). Group B was then divided into two subgroups: B1 (age 70-79 years) and B2 (age >or=80 years). We recorded the incidence of procedural complications and the long-term efficacy (mean follow-up 46 +/- 20 months). RESULTS: We studied 605 patients, 69% in group A and 31% in group B (24% in subgroup B1 and 7% in B2). The prevalence of structural heart disease was higher in elderly patients than in young adults (83 vs 37%, p < 0.01). The rate of procedural complications was 1.3%; no differences emerged between groups A and B (1.2 vs 1.5%, p = NS) or among groups A, B1 and B2 (1.2 vs 1.4 vs 2%, p = NS). The success rate of catheter ablation was 91%, with no differences between the age-groups (92 vs 88%, p = NS) or among groups A, B1 and B2 (92 vs 88 vs 88%, p = NS). CONCLUSION: Catheter ablation in elderly and very elderly patients is as effective and safe as in young-adult subjects, at least in cases which do not require left heart catheterization.


Asunto(s)
Arritmias Cardíacas/radioterapia , Ablación por Catéter/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento , Antiarrítmicos/farmacología , Arritmias Cardíacas/terapia , Cateterismo Cardíaco , Niño , Femenino , Humanos , Masculino , Persona de Mediana Edad , Riesgo , Factores de Tiempo
15.
Circulation ; 110(8): 911-4, 2004 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-15302779

RESUMEN

BACKGROUND: Creating linear lesions is important for the treatment of arrhythmias such as atrial flutter and fibrillation. Making these lesions with standard radiofrequency catheters can be difficult and may result in charring and thrombosis. The purpose of this study was to evaluate beta-radiation as a novel energy source for creating linear myocardial lesions. METHODS AND RESULTS: Eight dogs with intact conduction across the cavotricuspid isthmus were studied. The isthmus was irradiated (25 to 50 Gy) with strontium/yttrium-90 delivered via a deflectable 7F catheter (Novoste Corporation). There were no immediate effects, but bidirectional conduction block developed during follow-up studies in 7 of 8 dogs. The dog without conduction block received 25 Gy. After the animals were euthanized, histology revealed transmural, linear areas of fibrosis without any thrombus. CONCLUSIONS: Beta-radiation can safely and effectively create linear lesions that are contiguous and nonthrombogenic. This energy source may become an interesting adjunct to radiofrequency for the treatment of atrial flutter and fibrillation.


Asunto(s)
Arritmias Cardíacas/radioterapia , Partículas beta/uso terapéutico , Atrios Cardíacos/efectos de la radiación , Animales , Partículas beta/efectos adversos , Estimulación Cardíaca Artificial , Perros , Fibrosis , Atrios Cardíacos/patología , Bloqueo Cardíaco/etiología , Sistema de Conducción Cardíaco/efectos de la radiación , Traumatismos Experimentales por Radiación/etiología
16.
Rev. chil. cardiol ; 13(1): 8-15, ene.-mar. 1994. tab, ilus
Artículo en Español | LILACS | ID: lil-135491

RESUMEN

Entre enero y agosto de 1993 es realizaron 91 estudios electrofisiológicos para determinar el mecanismo de la taquicardia y efectuar eventual fulguración. En 10 pacientes (4 hombres y 6 mujeres), se documentó participación de la vía lenta del nódulo aurículo-ventricular en la taquicardia. La edad promedio fue de 38,7 años (rango 9-58). Ocho pacientes tenían taquicardias por reentrada en el nódulo aurículo-ventrícular (TRNAV) y 2 tenían asociación de taquicardias con participación de haz paraespecífico y TRNAV. La fulguración con radiofrecuencia se realizó ubicando un catéter Mansfield 7F en el ángulo posteroinferior del triángulo de Koch, el que se movilizó hasta obtener una relación A/V de 1/10 en ausencia de His. Se realizaron numerosos intentos de aplicación de radiofrecuencia a 500 KH, buscando obtener taquicardia nodal automática en relación a ella. Se interrumpieron los intentos cuando se documentó incapacidad de inducir TRNAV, ausencia de ecos y curva nodal única. En 8 pacientes se necesitaron 7,2 intentos y en 1 (en que se ensayó catéter diferente) 17 intentos, para bloquear la conducción de la vía lenta, con aplicación de 40 watts por 60 seg. La única complicación presentada fue la aparición transitoria (12 horas) de bloqueo completo de rama derecha, no en relación a la aplicación de la radiofrecuencia. Luego de 2,4 meses promedio (7 meses-15 días) todos los pacientes permanecen libres de arritmia en ausencia de tratamiento antiarrítmico. La fulguración de la vía lenta es un método de bajo riesgo y alta eficacia para curar las taquicardias por reentrada en el nodo aurículo-ventricular


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Arritmias Cardíacas/radioterapia , Electrocardiografía/métodos , Electrodos/estadística & datos numéricos , Taquicardia por Reentrada en el Nodo Atrioventricular/radioterapia , Terapia por Estimulación Eléctrica/métodos
17.
Kardiologiia ; 32(2): 66-8, 1992 Feb.
Artículo en Ruso | MEDLINE | ID: mdl-1527940

RESUMEN

Out of 85 patients with cardiac arrhythmias in the presence of chronic coronary heart disease, 28 who were resistant to ethacisine and allapinine were included into the study. They had frequent and persistent arrhythmias. The patients were divided into 2 groups: (1) the patients receiving intravenous He-Ne laser therapy in combination with one of the above drugs; (n = 17) and (2) those taking He-Ne laser therapy alone (n = 11). The efficacy of the therapies were controlled by 24-hour monitoring. An antiarrhythmic effect was more frequently observed when He-Ne laser was combined with one of the above drugs than when it was given alone (67.4 and 36.3%, respectively).


Asunto(s)
Arritmias Cardíacas/radioterapia , Terapia por Láser , Aconitina/análogos & derivados , Aconitina/uso terapéutico , Adulto , Anciano , Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/tratamiento farmacológico , Arritmias Cardíacas/etiología , Enfermedad Coronaria/complicaciones , Resistencia a Medicamentos , Helio , Humanos , Persona de Mediana Edad , Neón , Fenotiazinas/uso terapéutico
18.
Pacing Clin Electrophysiol ; 14(4 Pt 1): 557-76, 1991 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-1710061

RESUMEN

Precise location of the endocardial site of origin of ventricular tachycardia may facilitate surgical and catheter ablation of this arrhythmia. The endocardial catheter mapping technique can locate the site of ventricular tachycardia within 4-8 cm2 of the earliest site recorded by the catheter. This report describes an orthogonal electrode catheter array (OECA) for mapping and radiofrequency ablation (RFA) of endocardial focal site of origin of a plunge electrode paced model of ventricular activation in dogs. The OECA is an 8 F five pole catheter with four peripheral electrodes and one central electrode (total surface area 0.8 cm2. In eight mongrel dogs, mapping was performed by arbitrarily dividing the left ventricle (LV) into four segments. Each segment was mapped with OECA to find the earliest segment. Bipolar and unipolar electrograms were obtained. The plunge electrode (not visible on fluoroscopy) site was identified by the earliest wave front arrival times of -30 msec or earlier at two or more electrodes (unipolar electrograms) with reference to the earliest recorded surface ECG (I, AVF, and V1). Validation of the proximity of the five electrodes of the OECA to the plunge electrode was performed by digital radiography and RFA. Pathological examination was performed to document the proximity of the OECA to the plunge electrode and also for the width, depth, and microscopic changes of the ablation. To find the segment with the earliest LV activation a total of 10 +/- 3 (mean +/- SD) positions were mapped. Mean arrival times at the two earlier electrodes were -39 +/- 4 msec and -35 +/- 3 msec. Digital radiography showed the plunge electrode to be within the area covered by all five electrodes in all eight dogs. The plunge electrode was within 1 cm2 area of the region of RFA in all eight dogs. The width and depth of ablation were 5 +/- 3.5 and 7 +/- 3.5 mm, respectively. Microscopic changes revealed coagulative necrosis, hemorrhage, and inflammatory changes in all RFAs. In conclusion, the OECA can map the endocardial focal site of origin of paced ventricular activation within 1 cm2 area in a canine model. RFA from the OECA can cause discrete ablations representing all five electrodes or cross-shaped ablation connecting central electrode to all four peripheral electrodes. This catheter holds promise for extending surgical and clinical catheter ablation procedures.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Cateterismo/instrumentación , Electrocardiografía/instrumentación , Electrodos Implantados , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/inervación , Contracción Miocárdica , Animales , Arritmias Cardíacas/radioterapia , Estimulación Cardíaca Artificial , Perros , Electrocardiografía/métodos , Diseño de Equipo , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/efectos de la radiación , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/efectos de la radiación , Ondas de Radio , Intensificación de Imagen Radiográfica , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...