Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 281
Filtrar
1.
Plast Reconstr Surg ; 153(2): 442e-447e, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-37104497

RESUMEN

SUMMARY: The distal complex extensor tendon injury, presenting as traumatic skin, zones 1 and 2 of extensor pollicis longus and extensor hallucis longus, and bony insertion loss, represents a challenging issue and requires a well-vascularized skin paddle, tendinous graft, and insertional reconstruction. Guided by the all-in-one-step reconstruction rule, the chimeric superficial circumflex iliac artery perforator (SCIAP) flap, generally considered as a promising multiple-type tissue provider (eg, vascularized skin paddle, fascia, iliac flap), can fulfill the reconstructive demands and has an edge over the two-stage countermeasure. The authors adopted tripartite SCIAP flaps to reconstruct distal complex thumb or toe injuries in eight cases (six thumbs and two halluces), all of which were reattached with vascularized fascia lata-iliac crest conjunctions using a pull-out technique. All SCIAP flaps survived uneventfully without donor-site complications. The remodeled interphalangeal joints regained nearly normal radiologic manifestation. The chimeric SCIAP flap may be a promising technique for distal complex extensor tendon injury; providing vascularized skin paddle and fascia lata-iliac crest graft, it also qualifies for the all-in-one-stage reconstruction concept. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Asunto(s)
Colgajo Perforante , Procedimientos de Cirugía Plástica , Traumatismos de los Tendones , Humanos , Arteria Ilíaca/trasplante , Colgajo Perforante/irrigación sanguínea , Extremidad Inferior , Traumatismos de los Tendones/cirugía
2.
Transplant Proc ; 55(4): 1059-1061, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37085383

RESUMEN

Recently, the number of patients with significant arteriosclerosis has been increasing owing to the aging of kidney transplant patients, an increase in the number of patients with kidney failure with diabetes as the primary disease, and an increase in the number of patients undergoing long-term dialysis. Severe atherosclerosis in kidney transplant recipients makes it difficult to determine the site of vascular anastomosis and increases the technical difficulty of the surgical procedure. This study presents a case of upside-down kidney transplantation in a recipient with severe arteriosclerosis. The patient was a 58-year-old male with diabetic nephropathy. He received an ABO-compatible living donor kidney transplant from his wife. Preoperative computed tomography revealed a mild calcification of the external iliac artery. However, during surgery, more than half of the external iliac artery was found to be calcified, making vascular anastomosis difficult. The peripheral side of the external iliac artery showed mild atherosclerosis. Therefore, the vessel could be anastomosed to the peripheral side of the external iliac artery by turning the kidney graft upside-down for use as the anastomosis site. The postoperative course was uneventful, and the kidney function was good at the last follow-up. Upside-down kidney transplantation is safe in patients with severe arteriosclerosis.


Asunto(s)
Aterosclerosis , Trasplante de Riñón , Masculino , Humanos , Persona de Mediana Edad , Trasplante de Riñón/efectos adversos , Trasplante de Riñón/métodos , Diálisis Renal , Riñón , Tomografía Computarizada por Rayos X , Arteria Ilíaca/cirugía , Arteria Ilíaca/trasplante
3.
Microsurgery ; 43(5): 516-521, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37002191

RESUMEN

The management of arteriovenous malformations (AVMs) of the hand remains challenging. When radical excision results in large defects of both soft tissue and vessels, flow-through flap transfer is useful; however, flow-through flap options for hand and digit reconstructions are limited. Herein, we describe the use of a superficial circumflex iliac artery perforator (SCIP) flow-through flap after excision of an AVM of the hand. A 44-year-old female patient with an AVM of the hand required simultaneous reconstruction of soft tissue, vascular, and bone defects after radical excision of vascular lesions. A 6 × 15 cm SCIP flow-through flap was transferred, and flow-through vascular reconstruction was performed with flap vessels: the deep branch of the superficial circumflex iliac artery, superficial inferior epigastric artery, and superficial circumflex iliac vein. In addition, three bone holes in the proximal phalanx of the index finger were filled with iliac bone grafts. The postoperative course was uneventful, with good functional results 1 year after surgery. An SCIP flow-through flap is an option for reconstruction after excision of AVMs of the hand because of its advantages, including minimal donor-site morbidity, availability of multiple vessels suitable for anastomosis with hand vessels, and simultaneous availability of iliac bone grafts.


Asunto(s)
Malformaciones Arteriovenosas , Colgajo Perforante , Procedimientos de Cirugía Plástica , Femenino , Humanos , Adulto , Arteria Ilíaca/trasplante , Colgajo Perforante/irrigación sanguínea , Extremidad Inferior/cirugía , Malformaciones Arteriovenosas/cirugía
4.
Plast Reconstr Surg ; 149(3): 721-730, 2022 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35041628

RESUMEN

BACKGROUND: Head and neck tissue defects after ablative head and neck surgery often require complex and composite reconstructions. The superficial circumflex iliac artery perforator (SCIP) flap is an extremely versatile perforator-based flap with minimal donor-site morbidity. The authors present their experience with both simple and chimeric SCIP flap reconstructions for complex defects in various head and neck regions. METHODS: Twenty-two patients undergoing ablative head and neck surgery for oncologic abnormalities were treated by means of a SCIP flap reconstruction. Patients' mean age was 62 years; 21 were men and one was a woman. Seventeen flaps were simple and five were chimeric reconstruction patterns. Indocyanine green perfusion imaging was performed in all cases. RESULTS: Twenty-one of 22 patients (95.5 percent) were successfully treated with good aesthetic and functional results. Two patients (9 percent) showed minor donor-site complications that were managed conservatively. The mean follow-up period was 5.3 months (range, 2 to 8 months). CONCLUSIONS: This case series demonstrates the reliability and versatility of the SCIP flap for head and neck reconstruction. The chimeric options combined with bone, double-skin paddle, and muscle offer a broad variety of functional reconstructive solutions for complex head and neck surgery. Intraoperative indocyanine green perfusion examinations are a valuable tool to assess and ascertain proper inset, vitality, and postanastomosis vessel patency in these complex microvascular flap reconstructions. . CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Asunto(s)
Neoplasias de Cabeza y Cuello/cirugía , Arteria Ilíaca/trasplante , Colgajo Perforante/irrigación sanguínea , Procedimientos de Cirugía Plástica/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
5.
Plast Reconstr Surg ; 148(4): 615e-619e, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34550945

RESUMEN

BACKGROUND: A superficial circumflex iliac artery perforator flap has several advantages, such as reduced thickness, minimal donor-site morbidity, and inconspicuous scar. However, the application of a superficial circumflex iliac artery perforator flap is restricted because of its limited pedicle length. The aim of this article was to outline the technical modifications of superficial circumflex iliac artery perforator flap elevation to obtain long pedicles. METHODS: This is a prospective study of 31 consecutive patients who required a long pedicled superficial circumflex iliac artery perforator flap between September of 2016 and December of 2019 at the authors' center. According to a preoperatively marked pathway of the superficial branch of the superficial circumflex iliac artery, the superficial circumflex iliac artery perforator flap was designed. During the elevation, the design was modified according to the perforator location in the free-style technique. The characteristics of the patients and the flaps, including pedicle length, were recorded. The revision rate, complication rate, and need for a secondary procedure were analyzed. RESULTS: The mean follow-up period was 563 days (range, 92 to 1383 days). The mean length of the pedicle obtained was 6.9 cm (range, 6 to 8 cm) from the point where the pedicle merges into the flap. Long pedicles were anastomosed to the main source vessel or branch without tension. No major complications were reported. CONCLUSIONS: Overcoming the short pedicle length of a superficial circumflex iliac artery perforator flap by designing the flap laterally and performing an intraflap dissection is a reliable option when a longer pedicle is required, irrespective of the specific anatomy of the superficial circumflex iliac artery. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, IV.


Asunto(s)
Pie Diabético/cirugía , Arteria Ilíaca/trasplante , Colgajo Perforante/tendencias , Procedimientos de Cirugía Plástica/métodos , Herida Quirúrgica/cirugía , Anciano , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Colgajo Perforante/irrigación sanguínea , Estudios Prospectivos , Herida Quirúrgica/etiología , Resultado del Tratamiento
6.
Ann Vasc Surg ; 75: 531.e7-531.e13, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33836232

RESUMEN

The management of abdominal aortic aneurysms (AAA) has evolved significantly with the advent of endovascular strategies. Thus, there has been a decline in the number of open AAA repairs once an endovascular option is available. There have also been reports of successful endovascular management of infective native aortic aneurysms (INAA)1, previously called mycotic aneurysms2. The rarity of this condition makes its management a challenging one as there are no standard guidelines. The European Society of Vascular Surgery has suggested that the nomenclature be changed from mycotic aneurysms as this can be misleading to standardise reporting1. The authors' present a case of a 67-year old male who presented during the peak of the Corona Virus pandemic with constitutional gastrointestinal symptoms. He was subsequently diagnosed with an INAA and successfully managed with open Neo-Aorto Iliac System reconstruction with a homograft3. The report highlights various strategies used in the surgical approach and their benefits in the management of INAA. Furthermore, a literature review of Streptococcus (Streptococcus agalactiae) species as a rare cause of INAA and how these cases were managed are also highlighted.


Asunto(s)
Aneurisma Infectado/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Arteria Ilíaca/trasplante , Infecciones Estreptocócicas/cirugía , Streptococcus agalactiae/aislamiento & purificación , Injerto Vascular , Anciano , Aloinjertos , Aneurisma Infectado/diagnóstico , Aneurisma Infectado/microbiología , Antibacterianos/uso terapéutico , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/microbiología , Humanos , Masculino , Infecciones Estreptocócicas/diagnóstico , Infecciones Estreptocócicas/microbiología , Resultado del Tratamiento
7.
J Surg Oncol ; 123(4): 1067-1080, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33428783

RESUMEN

BACKGROUND: Postoperative complications after flap-coverage in sarcoma treatment can postpone postoperative adjunct treatments. Here, we present our experience with the use of the superficial circumflex iliac artery perforator (SCIP) flap after sarcoma resection. PATIENTS AND METHODS: Patients undergoing immediate reconstruction surgery with a flap after sarcoma resection at a single institution from February 2017 to April 2020 were identified. Patient demographics, tumor characteristics, surgical characteristics, and complications were examined. RESULTS: Thirty-five consecutive patients underwent reconstructions using a SCIP flap (34 free and one pedicled SCIP flaps). We also identified 47 consecutive patients who underwent reconstruction with other pedicled or free flaps over the same time period. No significant differences were found in patient age, gender, defect size, or operative time between these two groups. The incidences of overall complications (20/47 [42.6%] vs. 3/35 [8.5%], p < .001), flap dehiscence (7/47 [14.8%] vs. 0/35 [0%], p = .018), and total flap complications (15/47 [31.9%] vs. 2/35 [5.7%], p = .005) were statistically greater in the control group than in the SCIP group. CONCLUSION: With its minimal postoperative complication rate both in the reconstruction site and the donor site, the SCIP flap can be considered an optimal reconstruction option after sarcoma resection.


Asunto(s)
Colgajos Tisulares Libres/irrigación sanguínea , Arteria Ilíaca/trasplante , Colgajo Perforante/irrigación sanguínea , Colgajo Perforante/inervación , Procedimientos de Cirugía Plástica/métodos , Sarcoma/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Adulto Joven
8.
Exp Clin Transplant ; 18(6): 725-728, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33187464

RESUMEN

Autologous saphenous vein grafts are occasionally used in renal transplant recipients, particularly in living donors with short donor vessels or after donor vessel injury during allograft procurement. Autologous saphenous vein graft aneurysm formation is described as a late complication following the use of this conduit in renal transplant. We report a case of a 45-year-old woman who developed an autologous saphenous vein graft aneurysm 21 years after her living donor transplant, which was successfully managed with explantation of the graft, cold perfusion ex situ, and resection of the aneurysm, which was followed by reconstruction using deceased donor iliac vessels. The graft was then successfully reimplanted. Based on this experience and after a review of the literature related to autologous saphenous vein graft aneurysms in renal transplant, we recommend that surveillance for this particular complication should be considered no later than 10 years after implant of an autologous saphenous vein graft when used as an arterial conduit.


Asunto(s)
Aneurisma/cirugía , Arteria Ilíaca/trasplante , Trasplante de Riñón/efectos adversos , Nefrectomía , Arteria Renal/cirugía , Vena Safena/trasplante , Injerto Vascular/efectos adversos , Aneurisma/diagnóstico por imagen , Aneurisma/etiología , Femenino , Humanos , Persona de Mediana Edad , Perfusión , Arteria Renal/diagnóstico por imagen , Reoperación , Vena Safena/diagnóstico por imagen , Trasplante Autólogo , Resultado del Tratamiento
9.
Actas urol. esp ; 44(9): 623-629, nov. 2020. ilus, tab
Artículo en Inglés | IBECS | ID: ibc-198086

RESUMEN

ANTECEDENTES: El trasplante renal con variantes anatómicas vasculares sigue siendo un desafío. Debido a su éxito variable en lo que respecta a la función del injerto después del trasplante, estos órganos se descartan frecuentemente, asumiendo de antemano una tasa inasequible de complicaciones vasculares. PACIENTES Y MÉTODOS: Realizamos 3 trasplantes de riñón utilizando órganos de donantes fallecidos que presentaban variantes vasculares (arterias múltiples y venas cortas), incluyendo un riñón en herradura indivisible. Se utilizaron diferentes injertos extraídos de la aorta, la arteria ilíaca común y la vena cava inferior del mismo donante para reconstruir la configuración vascular inicial mediante la creación de conductos arteriales y venosos individuales, con el fin de simplificar la anastomosis vascular en el receptor. RESULTADOS: No se registraron complicaciones postoperatorias. Los tiempos de isquemia caliente fueron comparables con los de aloinjertos renales de una sola arteria. En ningún caso se observó un retraso en la función del injerto y todos los pacientes recuperaron la función renal normal después del trasplante. CONCLUSIONES: La reconstrucción vascular mediante injertos arteriales y venosos del mismo donante fallecido puede ser un recurso útil para simplificar la anastomosis vascular durante la cirugía de trasplante, evitando así su descarte de antemano, reduciendo al mínimo las complicaciones perioperatorias y permitiendo tasas normales de función de los injertos en el seguimiento a largo plazo. El resultado satisfactorio obtenido mediante la utilización de este enfoque ayudaría a ampliar los criterios de donantes para incluir órganos que presentan variantes anatómicas vasculares


BACKGROUND: Transplantation of kidneys with vascular anatomical variants remains a challenge. Due to its varying success in regard to graft function after transplantation, these organs have been frequently discarded assuming in advance an unaffordable rate of vascular complications. PATIENTS AND METHODS: We performed three kidney transplants using organs from deceased donors harboring vascular variants (multiple arteries and short veins), including an unsplittable horseshoe kidney. Different grafts harvested from the same donor aorta, common iliac artery, and inferior vena cava, were used to reconstruct the initial vascular configuration by creating single arterial and venous conduits aimed to simplify the vascular anastomoses in the recipient. RESULTS: No post-operative complications were recorded. Warm ischemia times remained comparable to single artery renal allografts. No delayed graft function was noted in any case, and every patient regained normal renal function after transplantation. CONCLUSIONS: Vascular reconstruction using arterial and venous grafts harvested from the same deceased donor may result a helpful tool to simplify vascular anastomoses during transplantation surgery, thus avoiding their discard in advance, minimizing perioperative complications, and enabling normal graft function rates in the long-term follow-up. The successful outcome obtained by using this approach would help to expand the donor criteria for the inclusion of organs containing vascular anatomical variants


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Fallo Renal Crónico/cirugía , Trasplante de Riñón/métodos , Riñón/irrigación sanguínea , Arteria Renal/trasplante , Cadáver , Derivación Arteriovenosa Quirúrgica/métodos , Aloinjertos , Resultado del Tratamiento , Vena Cava Inferior/trasplante , Arteria Ilíaca/trasplante , Aorta Abdominal/trasplante
10.
BMC Nephrol ; 21(1): 451, 2020 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-33115426

RESUMEN

BACKGROUND: Aging and mortality of patients on waiting lists for kidney transplantation have increased, as a result of the shortage of organs available all over the world. Living donor grafts represent a significant source to maintain the donor pool, and resorting successfully to allografts with arterial disease has become a necessity. The incidence of renal artery fibromuscular dysplasia (FMD) in potential living renal donors is reported to be 2-6%, and up to 4% of them present concurrent extra-renal involvement. CASE PRESENTATION: We present a case of renal transplantation using a kidney from a living donor with monolateral FMD. Resection of the affected arterial segment and its subsequent replacement with a cryopreserved iliac artery graft from a deceased donor were performed. No intraoperative nor post-operative complications were reported. The allograft function promptly resumed, with satisfying creatinine clearance, and adequate patency of the vascular anastomoses was detected by Doppler ultrasounds. CONCLUSION: Literature lacks clear guidelines on the eligibility of potential living renal donors with asymptomatic FMD. Preliminary assessment of the FMD living donor should always rule out any extra-renal involvement. Whenever possible, resection and reconstruction of the affected arterial segment should be taken into consideration as this condition may progress after implantation.


Asunto(s)
Displasia Fibromuscular/complicaciones , Arteria Ilíaca/trasplante , Fallo Renal Crónico/cirugía , Trasplante de Riñón/métodos , Donadores Vivos , Arteria Renal , Adulto , Enfermedades Asintomáticas , Nitrógeno de la Urea Sanguínea , Cadáver , Creatinina/sangre , Criopreservación , Tasa de Filtración Glomerular , Humanos , Arteria Ilíaca/fisiología , Fallo Renal Crónico/fisiopatología , Masculino , Arteria Renal/fisiología , Venas Renales/fisiología , Trasplante Homólogo , Grado de Desobstrucción Vascular
11.
Acta Med Okayama ; 74(3): 251-255, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32577024

RESUMEN

A 62-year-old Japanese male presented with graft infection by Staphylococcus schleiferi 50 days after debranching of the left subclavian artery and frozen elephant trunk repair for the entry closure of a Stanford type B aortic dissection. The graft was removed, and the patient was successfully treated using in situ reconstruction of the arch with omental flap coverage, removal of the debranching graft, autologous iliac artery grafting, and longterm antibiotics. Domino reconstruction of the infected debranching graft using autologous external iliac artery and a Dacron graft can thus be a good option in similar cases.


Asunto(s)
Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Infecciones Estafilocócicas/diagnóstico , Infección de la Herida Quirúrgica/microbiología , Injerto Vascular/efectos adversos , Antibacterianos/uso terapéutico , Humanos , Arteria Ilíaca/trasplante , Masculino , Persona de Mediana Edad , Reoperación , Staphylococcus/aislamiento & purificación , Infección de la Herida Quirúrgica/diagnóstico por imagen , Infección de la Herida Quirúrgica/tratamiento farmacológico , Injerto Vascular/métodos
12.
BMC Nephrol ; 21(1): 190, 2020 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-32434562

RESUMEN

BACKGROUND: Arterial reconstruction is one of the paramount procedures in kidney transplantation (KT) and greatly important if the procured kidney has multiple renal arteries (MRA). Despite various established techniques for arterial reconstruction, sometimes, the surgeon finds performing arterial anastomoses challenging in case of MRA. In our case, the donor's gonadal vein and recipient's internal iliac artery graft were used for arterial anastomoses, and 3 years after KT, the allograft did not present vascular complications. CASE PRESENTATION: A 34-year-old man underwent ABO-incompatible preemptive living KT. The allograft had three renal arteries and four renal veins. After donor nephrectomy, arterial reconstruction was performed on a back table. These arteries were reconstructed into one piece using the recipient's internal iliac artery graft. The two arteries at the middle of the renal hilum were reconstructed using the conjoined method. As the superior renal artery was too short to anastomose, the donor's gonadal vein was used for extension. The internal iliac artery graft was anastomosed to the original internal iliac artery. Intraoperative Doppler ultrasonography revealed that the blood flow in each renal artery was adequate, resulting in sufficient blood flow throughout the allograft. The allograft function was maintained with a serum creatinine level of approximately 0.9 mg/dL without vascular complications 3 years after KT. CONCLUSIONS: The donor's gonadal vein can be a candidate for extension of the renal artery in the allograft with MRA. Further follow-up is needed for the assessment of long-term outcomes.


Asunto(s)
Arteria Ilíaca/trasplante , Trasplante de Riñón/métodos , Donadores Vivos , Arteria Renal/cirugía , Trasplantes/irrigación sanguínea , Injerto Vascular/métodos , Venas/trasplante , Adulto , Anastomosis Quirúrgica/métodos , Humanos , Masculino , Procedimientos de Cirugía Plástica/métodos , Arteria Renal/anomalías , Venas Renales
13.
Transplant Proc ; 52(4): 1102-1105, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32204898

RESUMEN

BACKGROUND: A short right renal vein (RRV) remains a challenge for renal transplant surgery, especially in the living donor. Different techniques exist to obtain an RRV with a suitable length in cadaveric donor; however, in living donors the options are limited. MATERIAL AND METHODS: We present 2 living kidney transplants in which we obtained a very short RRV, making the implantation very difficult. We describe our technique to overcome this problem by using cadaveric iliac vessels retrieved from previous cadaveric donations and preserved at 4°C in histidine-tryptophan-ketoglutarate (HTK) solution, without intraoperative or postoperative complications. We complied with the Helsinki Congress and the Istanbul Declaration regarding the donor source. RESULTS: In both cases, kidney grafts had optimal primary function, with good creatinine clearance after transplant and good patency of vascular anastomosis by Doppler ultrasounds. CONCLUSIONS: We believe the use of cadaveric vessel grafts in living donor kidney transplant is a valuable resource as a rescue tool in emergency situations like the ones being presented in this article in order to avoid discarding a kidney graft with damage or short vessels. This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.


Asunto(s)
Arteria Ilíaca/trasplante , Trasplante de Riñón/métodos , Donadores Vivos , Venas Renales , Aloinjertos , Cadáver , Humanos , Masculino , Persona de Mediana Edad , Trasplante Homólogo
15.
Ann Vasc Surg ; 64: 17-26, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31904522

RESUMEN

BACKGROUND: The aim of the study was to report the results of conventional surgery for renal artery aneurysms (RAAs) in our center. MATERIAL AND METHODS: We retrospectively reviewed the files of all the patients operated for RAAs between 2009 and 2018 in our center. We collected demographic, biological (renal function), morphological (computed tomography [CT] scan), and functional (ultrasound examination and resistance index) preoperative and postoperative data. Clinical and paraclinical operative data were examined. Results were expressed as average ± standard deviation or median and extremes. RESULTS: A total of 26 aneurysms were operated in 20 kidneys (10 right kidneys) among 19 patients, including 13 (68%) women with an average age of 55 (±12) years. Three (16%) patients presented an aneurysm in a single kidney. The discovery of the aneurysm was fortuitous in 14 (74%) patients. One patient with Marfan syndrome was operated after a postpartum rupture. The median diameter of the operated aneurysms was 22 mm (7-48), and 23 (90%) were hilar aneurysms. Arterial repair was carried out in situ in 16 (80%) kidneys. The surgery consisted of a direct arterial repair in 21 cases (81%), including 4 resections and anastomoses, 12 aneurysmorrhaphies, and 5 complex reconstructions. Four arterial replacements were carried out (one prosthetic graft, 2 femoral grafts, and one internal iliac graft). The average duration of renal clamping was 30.5 (±17.3) min. Postoperative renal function was unchanged in all the patients except for one (5.2%) who required 2 days of postoperative dialysis. The resistance index of all the operated kidneys was normal (0.66 ± 0.08) at discharge. Sixteen (70%) of the 23 aneurysms were examined, and anatomopathology concluded them to be of dysplastic origin. At 3 months, a systematic CT scan objectified the patency of 95% of the arterial reconstructions, with 3 stenoses >50%. One stenosis >80% was treated at 7 months by balloon angioplasty. Only one operated kidney presented a loss of viability of its upper pole. The mean duration of follow-up was 54 ± 35 months. By the end of the follow-up, primary and secondary patency rates evaluated by Doppler ultrasound were 90% and 95%, respectively. CONCLUSIONS: Conventional surgery generally performed in situ remains a sure and effective treatment for RAAs. This challenging surgery for a rare disease should be performed in experimented centers.


Asunto(s)
Aneurisma/cirugía , Implantación de Prótesis Vascular , Arteria Femoral/trasplante , Arteria Ilíaca/trasplante , Arteria Renal/cirugía , Adulto , Anciano , Aneurisma/diagnóstico por imagen , Aneurisma/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Femenino , Francia , Humanos , Masculino , Persona de Mediana Edad , Arteria Renal/diagnóstico por imagen , Arteria Renal/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
16.
Urology ; 138: 179-187, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31911083

RESUMEN

OBJECTIVE: To describe the novel surgical technique of urethral lengthening in anterolateral thigh and superficial circumflex iliac artery perforator flap phalloplasty with a pedicled labia minora flap (PLMF) and report on the clinical outcomes. METHODS: Between March 2014 and August 2018, 16 transgender men underwent phalloplasty with a PLMF for urethral lengthening at the Amsterdam UMC (VU university), the Netherlands and the Belgrade University Hospital, Serbia. Patient demographics, surgical characteristics, neourethra characteristics, intra- and postoperative complications, pre-and postoperative voiding evaluation, and the length of hospital stay were retrospectively identified from chart reviews. RESULTS: The mean neourethral length was 16.8 ± 2.3 cm, and the pars pendulans 11.7 ± 2.2 cm. The neomeatus was localized on top of the neophallus in 12 (75%) patients. No intraoperative complications occurred. Urethral fistula formation occurred in 4 (25%) patients and strictures in 6 (37.5%) patients. In 3 (18.7%) patients a (temporary) perineostomy had to be performed. Voiding from a standing position was possible in 9 (56.3%) patients. CONCLUSION: The PLMF for urethral reconstruction, both pars fixa and pars pendulans, in phalloplasty is a feasible surgical technique in transgender men undergoing anterolateral thigh or superficial circumflex iliac artery perforator flap phalloplasty with sufficient labia minora tissue.


Asunto(s)
Pene/cirugía , Procedimientos de Cirugía Plástica/métodos , Cirugía de Reasignación de Sexo/métodos , Uretra/cirugía , Vulva/cirugía , Adolescente , Adulto , Estudios de Factibilidad , Femenino , Humanos , Arteria Ilíaca/trasplante , Masculino , Persona de Mediana Edad , Colgajo Perforante/trasplante , Muslo , Personas Transgénero , Resultado del Tratamiento , Adulto Joven
17.
J Plast Reconstr Aesthet Surg ; 72(9): 1478-1483, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31204153

RESUMEN

BACKGROUND: Bony free flaps are used to reconstruct head and neck cancer defects. The most commonly used flaps are the free fibula flap and the deep circumflex iliac artery (DCIA) flap. Radiotherapy may be given post-operatively to prevent cancer recurrence. This radiotherapy can, however, destroy the bone; a complication termed osteoradionecrosis (ORN). Although there have been studies comparing free fibula and DCIA flaps in terms of success rates and complications, few have assessed the incidence of ORN in both groups. METHODS: A retrospective cohort study was conducted involving patients from Royal Melbourne Hospital and St Vincent's Hospital Melbourne who had either a free fibula or DCIA flap for head and neck cancer reconstruction in the past 10 years. Data collected included demographic, operative, and postoperative data. Analysis was performed using Statistical Package for Social Sciences and Microsoft Excel, utilising t-tests, chi-square tests and logistic regression analyses. RESULTS: A total of 154 patients were identified. Of these patients, 127 had free fibula flaps and 27 had free DCIA flaps. Twelve patients had ORN post-op, 10 had free fibula flaps, and 2 had free DCIA flaps. No statistically significant difference was found between the ORN rates in free fibula flaps and free DCIA flaps. CONCLUSION: Rates of ORN incidence should not be a major consideration in preoperative planning of free flaps for mandibular reconstruction as both fibula and DCIA free flaps are comparable.


Asunto(s)
Trasplante Óseo/métodos , Peroné/trasplante , Neoplasias de Cabeza y Cuello/cirugía , Arteria Ilíaca/trasplante , Mandíbula/efectos de la radiación , Reconstrucción Mandibular/métodos , Osteorradionecrosis/epidemiología , Femenino , Peroné/efectos de la radiación , Estudios de Seguimiento , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Incidencia , Masculino , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Persona de Mediana Edad , Osteorradionecrosis/diagnóstico , Osteorradionecrosis/etiología , Radiografía Panorámica , Radioterapia Adyuvante/efectos adversos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Victoria/epidemiología
18.
Microsurgery ; 39(5): 441-446, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31112634

RESUMEN

BACKGROUND: During flap surgery, the dominant perforator is usually selected as the pedicle. This study investigated the effect of a nondominant perforator on multiterritory perforator flap survival. METHODS: The deep circumflex iliac artery perforator flap (DCIA flap) and intercostal artery perforator flap (ICA flap) were performed (n = 12). Only the pedicle was different between the two flaps. The DCIA flap was based on the right and peripheral DCIA with three dynamic and two potential perforasomes. The ICA flap was based on the right and central ICA with five dynamic perforasomes. All adjacent perforators were ligated except the pedicle. On postoperative day 7, flap viability, angiography findings, and perfusion were compared. RESULTS: Even though the diameter of DCIA (mm) was larger than that of ICA (0.49 ± 0.03 vs. 0.4 ± 0.04; p < .05), the ICA flap survival rate (%) was higher than that of DCIA flap (99.5 ± 0.7 vs. 83.8 ± 3.9; p < .001). Based on a dominant perforator, a necrotic area was observed in the potential perforasomes of the DCIA flap. The choke vessels between the anatomical and dynamic perforasomes dilated postoperatively in the two flaps, whereas the others did not. The perfusion (PU) differences between the DCIA and ICA flaps in the dynamic perforasomes were nonsignificant (average, 342.4 ± 9.1 vs. 347.3 ± 7.3; p > .05). CONCLUSION: Increasing the number of dynamic perforasomes had no effect on flap survival, even based on a nondominant perforator. And the pedicle position affected flap survival.


Asunto(s)
Supervivencia de Injerto , Arteria Ilíaca/trasplante , Músculos Intercostales/irrigación sanguínea , Colgajo Perforante/irrigación sanguínea , Colgajo Perforante/trasplante , Angiografía/métodos , Animales , Modelos Animales de Enfermedad , Rechazo de Injerto , Arteria Ilíaca/cirugía , Distribución Aleatoria , Ratas , Ratas Sprague-Dawley , Flujo Sanguíneo Regional/fisiología , Sensibilidad y Especificidad
19.
Microsurgery ; 39(4): 354-359, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30767266

RESUMEN

Post-traumatic lymphedema is poorly understood. It is rarely considered in limb reconstruction decision-making approach. We report a case of a 41-year-old female who presented with right upper extremity lymphedema after degloving injury and split thickness skin graft, successfully treated with a superficial circumflex iliac artery perforator (SCIP) free flap restoring the lymphatic drainage. Right upper extremity had an excess of 258.7 mL or an excess volume of 27.86% compared to the healthy contralateral limb. A SCIP free flap including lymphatic vessels (SCIP-L) was performed to replace the skin graft in order to restore the lymphatic flow. Flap size was 19 × 8 cm and pedicle length was 4 cm. No lymph nodes were included and no lymphatic or lymphovenous anastomoses were performed. The surgery was uneventful, and there were no postoperative complications. Fourteen days after free tissue transfer, lymphedema showed clear improvement. At a 4-month follow-up, 55.6% reduction of excess volume was obtained. Indocyanine green lymphography performed at that time showed a restitution of lymph flow through the flap. Lymphedema improvements persisted at a 6-month follow-up. A successful treatment of post-traumatic lymphedema can be performed by using the SCIP-L free flap for soft tissue reconstruction of critical lymphatic drainage areas.


Asunto(s)
Brazo/cirugía , Lesiones por Desenguantamiento/cirugía , Arteria Ilíaca/trasplante , Vasos Linfáticos/trasplante , Linfedema/cirugía , Colgajo Perforante/irrigación sanguínea , Colgajo Perforante/cirugía , Adulto , Femenino , Humanos , Complicaciones Posoperatorias/cirugía , Reoperación
20.
J Plast Reconstr Aesthet Surg ; 72(5): 759-762, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30611677

RESUMEN

INTRODUCTION: Perioperative microsurgical planning increases the likelihood of successful results. Augmented reality (AR) is the addition of artificial information to allow the user to perform tasks more efficiently. The aim of our study is to report the use of AR for microsurgical planning with a smartphone (ARM-PS) as a dissection route map. PATIENTS AND METHODS: AR was used for superficial circumflex iliac artery perforator (SCIP) flap planning. Three-dimensional (3D) reconstruction images of the inguinal and lower abdomen vascular anatomy were obtained by computed tomography angiography. These 3D images were imported to a smartphone and an AR app was used to superimpose them with the camera. The drawings performed with ARM-PS were correlated with handheld Doppler and intraoperative findings. RESULTS: The correlation of ARM-PS drawings with handheld Doppler results was 100% for superficial inferior epigastric artery (SIEA) and superficial and deep branches of SCIP in 60 inguinal areas studied. Intraoperative findings matched perfectly in all 30 cases with ARM-PS drawings for the location of the mentioned vessels and lymph nodes. Flap harvest time decreased in 20% compared with our traditional timing. CONCLUSIONS: ARM-PS is an easy, noninvasive, and accurate method that provides a dissection route map, thereby standardizing flap harvesting, and shows a perfect correlation with intraoperative findings. It reduces operating time and may improve operative results, thus decreasing donor site morbidity.


Asunto(s)
Realidad Aumentada , Microcirugia/métodos , Aplicaciones Móviles , Humanos , Arteria Ilíaca/patología , Arteria Ilíaca/trasplante , Imagenología Tridimensional/métodos , Colgajo Perforante/patología , Periodo Preoperatorio , Teléfono Inteligente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...