Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 954
Filtrar
1.
Semin Arthritis Rheum ; 66: 152437, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38564998

RESUMEN

Inter-reader reliability of a new scoring system for evaluating joint inflammation and enthesitis in whole body MRI (WBMRI) in juvenile idiopathic arthritis was tested. The scoring system grades 732 item-region combinations of bone marrow and soft tissue changes for commonly involved joints and entheseal sites. Five radiologists rated 17 WBMRI scans through an online rating platform. Item-wise reliability was calculated for 117 items with non-zero scores in >10 % of readings. Interquartile ranges of the five-reader Kappa reliability coefficients were 0.58-0.73 (range: 0.36-0.88) for the joints, 0.65-0.81 (range: 0.39-0.95) for the entheses, and 0.62-0.75 (range: 0.60-0.76) for chronic nonbacterial osteomyelitis-like lesions.


Asunto(s)
Artritis Juvenil , Imagen por Resonancia Magnética , Imagen de Cuerpo Entero , Humanos , Artritis Juvenil/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Niño , Imagen de Cuerpo Entero/métodos , Masculino , Índice de Severidad de la Enfermedad , Femenino , Adolescente , Articulaciones/diagnóstico por imagen , Preescolar
3.
Skeletal Radiol ; 53(2): 195-208, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37354318

RESUMEN

Ultrasound (US)-guided musculoskeletal intervention of small joints or joints other than the shoulder, elbow, hip, knee, and ankle can be technically challenging. Small joints produce a narrower landing zone for the needle and a smaller target that may be made even more inaccessible by bulky osteophytes. Sonographic (US) guidance offers important advantages including near-field visualization of the joint and soft tissues, ease of access, portability, ability to compare with the contralateral side, and lack of ionization radiation. This review article focuses on the performance of US-guided injections and aspirations involving small joints (joint capacity < 2 mL and/or typically evaluated or injected with a compact linear transducer). For each joint (temporomandibular, acromioclavicular, sternoclavicular, distal radioulnar, symphysis pubis, and joints of the digits of the hands and feet), a brief overview of the relevant anatomy, indications, procedural description, pearls and pitfalls will be highlighted. This article demonstrates the various approaches to diagnostic or therapeutic injection and aspiration of small joints with the aid of US images, cines and graphic illustrations, emphasizing joint positioning, anatomic landmarks, and needle trajectory for a safe and efficacious procedure. A brief review of available literature for each joint will also be provided.


Asunto(s)
Hombro , Ultrasonografía Intervencional , Humanos , Inyecciones Intraarticulares/métodos , Ultrasonografía Intervencional/métodos , Ultrasonografía , Rodilla , Articulaciones/diagnóstico por imagen
4.
Acad Radiol ; 31(4): 1528-1537, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37777427

RESUMEN

RATIONALE AND OBJECTIVES: The purpose of this study is to conduct a comparison between the newly introduced Angio PLanewave UltraSensitive (AngioPLUS) method and the power Doppler ultrasound (PDUS) technique, evaluating the efficacy of these two methods in detecting synovial blood flow in wrist and finger joints of rheumatoid arthritis (RA) patients. Furthermore, the study aimed to investigate the potential associations between the observed blood flow patterns and various symptoms and indicators associated with RA. MATERIALS AND METHODS: A cohort of 101 patients diagnosed with RA was included and subsequently categorized into two groups: 20 male participants (19.80%) and 81 female participants (80.20%). Their grayscale ultrasound, PDUS, and AngioPLUS were utilized to acquire data, and subsequent scoring was conducted. Serological tests of the patients were also performed, and DAS28 scores were calculated. The McNemar and Wilcoxon tests were used to compare the blood flow display rate and grading of PDUS as well as AngioPLUS, respectively. RESULTS: AngioPLUS blood was significantly improved compared to PDUS. In all joints, the proportion of slight and significant improvement in wrist joints was the highest (14.11% and 1.98%, respectively). AngioPLUS was moderately correlated with C-reactive Protein (CRP), Disease Activity Score that includes 28-joint counts, and swollen joint counts and weakly correlated with platelet, hemoglobin, tender joint counts, and CRP before and after treatment. CONCLUSION: Compared to PDUS, AngioPLUS has a better auxiliary diagnostic role in evaluating disease activity and can provide a reference to improve the management of RA further.


Asunto(s)
Artritis Reumatoide , Articulaciones de los Dedos , Humanos , Masculino , Femenino , Muñeca , Ultrasonografía Doppler/métodos , Artritis Reumatoide/diagnóstico por imagen , Articulación de la Muñeca/diagnóstico por imagen , Proteína C-Reactiva , Índice de Severidad de la Enfermedad , Articulaciones/diagnóstico por imagen
5.
Sci Rep ; 13(1): 17354, 2023 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-37833397

RESUMEN

Irrespective of the exceptional adaptation of dromedaries to harsh environmental conditions, they remain highly susceptible to joint lameness resulting from a range of diverse factors and conditions. The joints most often affected by traumatic osteoarthritis in dromedaries are the metacarpophalangeal and metatarsophalangeal joints. A comprehensive understanding of joint anatomy and topography of the dromedary is required to perform arthrocentesis correctly on affected joints. Forty-two distal limbs were taken from 28 camels and studied by gross dissection, casting, ultrasonography, and computed tomography (CT). Representative three-dimensional models of the joint cavities, recesses, and pouches were obtained using different casting agents. This study provides a detailed description of dorsally, axially, and abaxially positioned joint recesses, as well as palmar/plantar positioned joint pouches. The safety and feasibility of the different arthrocentesis approaches were evaluated. The traditional dorsal arthrocentesis approach of the metacarpophalangeal, metatarsophalangeal, proximal interphalangeal, and distal interphalangeal joints, has limitations due to the risk of damaging the tendon structures and articular cartilage, which can lead to joint degeneration. A lateral arthrocentesis approach via the proximal palmar/plantar pouches of the metacarpophalangeal/metatarsophalangeal and proximal interphalangeal joints is recommended. This approach eliminates the potential needle injury to the articulating joint cartilage and other surrounding joint structures, such as tendons, blood vessels, and nerves.


Asunto(s)
Cartílago Articular , Articulación Metatarsofalángica , Animales , Camelus , Artrocentesis , Miembro Anterior , Articulaciones/diagnóstico por imagen , Articulaciones/cirugía , Articulación Metatarsofalángica/diagnóstico por imagen , Articulación Metatarsofalángica/cirugía
9.
Vet Comp Orthop Traumatol ; 36(3): 132-138, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36724814

RESUMEN

OBJECTIVE: The objective of this prospective study was to evaluate the use of ultrasonography in the diagnosis of medial coronoid process disease in unclear cases. STUDY DESIGN: Fifteen elbows (on thirteen dogs) for which radiography and computed tomography did not lead to a clear diagnosis of medial coronoid process disease were included. On each elbow, ultrasonography was performed with a high frequency linear transducer (12-18Hz). Then, arthroscopic examination of the joint was performed by a surgeon who was unaware of ultrasonographic findings to confirm medial coronoid process disease. RESULTS: At least one ultrasonographic lesion was detected in 13 out of 15 elbows. The main reported ultrasonographic lesions were joint effusion (10/15 elbows) and an abnormal shape of the medial coronoid process (irregular, ill-defined or fragmented) (9/15). CONCLUSION: Ultrasonography can be a helpful additional diagnostic tool to confirm medial coronoid process disease of the elbow joint before performing arthroscopy in unclear cases. Further studies will be needed to evaluate the use of higher frequency transducers and determine if it could improve the diagnostic value of ultrasonography.


Asunto(s)
Enfermedades de los Perros , Articulación del Codo , Artropatías , Perros , Animales , Articulación del Codo/patología , Articulaciones/diagnóstico por imagen , Codo/patología , Estudios Prospectivos , Enfermedades de los Perros/cirugía , Ultrasonografía/veterinaria , Miembro Anterior/cirugía , Artropatías/diagnóstico por imagen , Artropatías/veterinaria , Artropatías/patología
11.
J Ultrasound Med ; 42(3): 701-712, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35984090

RESUMEN

BACKGROUND: Teleguidance on portable devices opens the possibility of joint self-imaging in persons with hemophilia (PWH). AIMS: Determine the feasibility of patient self-imaging with/without teleguidance. METHODS: Adult PWH received ultrasound teaching including 11 views for hemarthrosis detection in ankles, elbows, and knees. The patients acquired five randomly selected views with the Butterfly/IQ probe without assistance at 2, 6-8 weeks, and 3-4 months later, followed by teleguidance. Image acquisition was timed, patients identified anatomic landmarks, and image quality was graded. Questionnaires assessed the imaging experience. Hemophilia Joint Health Score (HJHS) indicated arthropathy status. RESULTS: Of 132 PWH, 10 (median age 52 years) opted for study inclusion. Most had severe Hemophilia A, were white/non-Hispanic, with at least a high school degree and, overall, similar to the other 122 PWH. At 2 and 6 weeks after training, ~80% images were acquired correctly compared with 53% at 12 weeks. Accuracy of landmark recognition was ~55%. With teleguidance, all images were acquired correctly, with near-perfect image quality (P ≤ .01 compared with the 3-4 month time point). Median HJHS of scanned joints was 11.5 at each time point, demonstrating a similar spectrum of arthropathic changes. Median time of image acquisition was fast, and similar with or without teleguidance (median 01:04 [mm:ss] vs median 01:02), but differed slightly between arthropathic and non-arthropathic joints. Study participants and the imaging facilitator rated that it was easy to navigate mobile technology and acquire images with teleguidance. CONCLUSION: Mobile ultrasound with teleguidance for joint self-imaging is feasible and warrants further exploration.


Asunto(s)
Articulación del Codo , Hemofilia A , Adulto , Humanos , Persona de Mediana Edad , Hemofilia A/complicaciones , Hemofilia A/diagnóstico por imagen , Proyectos Piloto , Hemartrosis/diagnóstico , Ultrasonografía/métodos , Articulaciones/diagnóstico por imagen
12.
Skeletal Radiol ; 52(5): 897-909, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35962837

RESUMEN

Ultrasound guidance is valuable for performing precise joint interventions. Joint interventions may be requested for therapeutic and diagnostic pain injections, joint aspiration in the setting of suspected infection, or contrast injection for arthrography. In practice, interventions of the shoulder girdle, elbow, and hand/wrist joints may be performed without any imaging guidance. However, imaging guidance results in more accurate interventions and better patient outcomes than those performed by palpation alone. When compared to other modalities used for imaging guidance, ultrasound has many potential advantages. Radiologists should be prepared to perform ultrasound-guided upper extremity joint interventions utilizing recommended techniques to optimize clinical practice and patient outcomes. KEY POINTS: 1. Ultrasound-guided injections of the glenohumeral, acromioclavicular, sternoclavicular, elbow, and hand/wrist joints have higher accuracy than injections performed without imaging guidance. 2. Ultrasound-guided aspirations of upper extremity joints have advantages to fluoroscopic-guided aspirations because of the potential to identify effusions, soft tissue abscess, or bursitis. 3. Ultrasound-guided contrast injection prior to MR arthrography is as accurate as fluoroscopic-guided injection for upper extremity joints.


Asunto(s)
Articulaciones , Ultrasonografía Intervencional , Humanos , Inyecciones Intraarticulares/métodos , Ultrasonografía Intervencional/métodos , Articulaciones/diagnóstico por imagen , Ultrasonografía , Medios de Contraste , Extremidad Superior
13.
J Rheumatol ; 50(2): 236-239, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36182106

RESUMEN

OBJECTIVE: Musculoskeletal ultrasound (MSUS) is increasingly being used in the evaluation of pediatric musculoskeletal diseases. In order to provide objective assessments of arthritis, reliable MSUS scoring systems are needed. Recently, joint-specific scoring systems for arthritis of the pediatric elbow, wrist, and finger joints were proposed by the Childhood Arthritis and Rheumatology Research Alliance (CARRA) MSUS workgroup. This study aimed to assess the reliability of these scoring systems when used by sonographers with different levels of expertise. METHODS: Members of the CARRA MSUS workgroup attended training sessions for scoring the elbow, wrist, and finger. Subsequently, scoring exercises of B mode and power Doppler (PD) mode still images for each joint were performed. Interreader reliability was determined using 2-way single-score intraclass correlation coefficients (ICCs) for synovitis and Cohen [Formula: see text] for tenosynovitis. RESULTS: Seventeen pediatric rheumatologists with different levels of MSUS expertise (1-15 yrs) completed a 2-hour training session and calibration exercise for each joint. Excellent reliability (ICC > 0.75) was found after the first scoring exercise for all the finger and elbow views evaluated on B mode and PD mode, and for all of the wrist views on B mode. After a second training session and a scoring exercise, the wrist PD mode views reached excellent reliability as well. CONCLUSION: The preliminary CARRA MSUS scoring systems for assessing arthritis of the pediatric elbow, wrist, and finger joints demonstrate excellent reliability among pediatric MSUS sonographers with different levels of expertise. With further validation, this reliable joint-specific scoring system could serve as a clinical tool and scientific outcome measure.


Asunto(s)
Artritis Juvenil , Muñeca , Humanos , Niño , Articulaciones de los Dedos , Codo , Reproducibilidad de los Resultados , Ultrasonografía/métodos , Articulaciones/diagnóstico por imagen
14.
Arthritis Res Ther ; 24(1): 227, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36192761

RESUMEN

BACKGROUND: X-ray images are commonly used to assess the bone destruction of rheumatoid arthritis. The purpose of this study is to propose an automatic-bone-destruction-evaluation system fully utilizing deep neural networks (DNN). This system detects all target joints of the modified Sharp/van der Heijde score (SHS) from a hand X-ray image. It then classifies every target joint as intact (SHS = 0) or non-intact (SHS ≥ 1). METHODS: We used 226 hand X-ray images of 40 rheumatoid arthritis patients. As for detection, we used a DNN model called DeepLabCut. As for classification, we built four classification models that classify the detected joint as intact or non-intact. The first model classifies each joint independently, whereas the second model does it while comparing the same contralateral joint. The third model compares the same joint group (e.g., the proximal interphalangeal joints) of one hand and the fourth model compares the same joint group of both hands. We evaluated DeepLabCut's detection performance and classification models' performances. The classification models' performances were compared to three orthopedic surgeons. RESULTS: Detection rates for all the target joints were 98.0% and 97.3% for erosion and joint space narrowing (JSN). Among the four classification models, the model that compares the same contralateral joint showed the best F-measure (0.70, 0.81) and area under the curve of the precision-recall curve (PR-AUC) (0.73, 0.85) regarding erosion and JSN. As for erosion, the F-measure and PR-AUC of this model were better than the best of the orthopedic surgeons. CONCLUSIONS: The proposed system was useful. All the target joints were detected with high accuracy. The classification model that compared the same contralateral joint showed better performance than the orthopedic surgeons regarding erosion.


Asunto(s)
Artritis Reumatoide , Aprendizaje Profundo , Artritis Reumatoide/diagnóstico por imagen , Progresión de la Enfermedad , Humanos , Articulaciones/diagnóstico por imagen , Radiografía , Índice de Severidad de la Enfermedad
15.
Biomed Res Int ; 2022: 7358575, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36046441

RESUMEN

Numerous traditional medical imaging methods, including computed tomography with X-rays, positron emission tomography (PET), and magnetic resonance imaging (MRI), are utilized frequently in medical settings to screen for illnesses, diagnose patients, and track the effectiveness of treatments. When examining bone protrusions, CT is preferred over MRI for scanning connective tissue. Although the picture quality of PET is inferior to that of CT and MR, it is outstanding for detecting the molecular markers and metabolic functions of illnesses. To give high-resolution structural pictures and improved ailment sensitivity and specificity within another image, multimodal data and substantial therapeutic influence on advanced diagnostics and therapeutics have been used. The goal was to evaluate the clinical significance of multimodal photoacoustic/ultrasound (PA/US) articular imaging scoring, a cutting-edge image technique that may show the microvessels and oxygen levels of rheumatoid arthritis-related inflamed joints (RA). The PA/US imaging technology analyzed seven tiny joints. The PA and power Doppler (PD) impulses were semiquantified using a 0-3 grading scale, and the averages of the PA and PD scores for the seven joints are computed. Three PA+SO2 types were found determined by the relative oxygen levels (SO2) measurements of the affected joints. Researchers evaluated the relationships between the disease activity ratings and the PA/US imaging ratings. The PA scores and medical ratings that reflect the extent of the pain have strong relationships with each other, as do the PA+SO2 combinations. PA may be clinically useful in assessing RA. Thus, the research evaluated the clinical symptoms of inflammatory arthritis using a multimodal photoacoustic image process.


Asunto(s)
Artritis Reumatoide , Técnicas Fotoacústicas , Artritis Reumatoide/diagnóstico por imagen , Humanos , Articulaciones/diagnóstico por imagen , Imagen por Resonancia Magnética , Oxígeno , Tomografía de Emisión de Positrones
16.
BMC Vet Res ; 18(1): 328, 2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-36045350

RESUMEN

BACKGROUND: Osteochondrosis is a major cause of leg weakness in pigs. Selection against osteochondrosis is currently based on manual scoring of computed tomographic (CT) scans for the presence of osteochondrosis manifesta lesions. It would be advantageous if osteochondrosis could be diagnosed automatically, through artificial intelligence methods using machine learning. The aim of this study was to describe a method for labelling articular osteochondrosis lesions in CT scans of four pig joints to guide development of future machine learning algorithms, and to report new observations made during the labelling process. The shoulder, elbow, stifle and hock joints were evaluated in CT scans of 201 pigs. RESULTS: Six thousand two hundred fifty osteochondrosis manifesta and cyst-like lesions were labelled in 201 pigs representing a total volume of 211,721.83 mm3. The per-joint prevalence of osteochondrosis ranged from 64.7% in the hock to 100% in the stifle joint. The lowest number of lesions was found in the hock joint at 208 lesions, and the highest number of lesions was found in the stifle joint at 4306 lesions. The mean volume per lesion ranged from 26.21 mm3 in the shoulder to 42.06 mm3 in the elbow joint. Pigs with the highest number of lesions had small lesions, whereas pigs with few lesions frequently had large lesions, that have the potential to become clinically significant. In the stifle joint, lesion number had a moderate negative correlation with mean lesion volume at r = - 0.54, p < 0.001. CONCLUSIONS: The described labelling method is an important step towards developing a machine learning algorithm that will enable automated diagnosis of osteochondrosis manifesta and cyst-like lesions. Both lesion number and volume should be considered during breeding selection. The apparent inverse relationship between lesion number and volume warrants further investigation.


Asunto(s)
Quistes , Osteocondrosis , Enfermedades de los Porcinos , Animales , Inteligencia Artificial , Quistes/veterinaria , Articulaciones/diagnóstico por imagen , Articulaciones/patología , Aprendizaje Automático , Osteocondrosis/diagnóstico por imagen , Osteocondrosis/epidemiología , Osteocondrosis/veterinaria , Porcinos , Enfermedades de los Porcinos/epidemiología , Tomografía Computarizada por Rayos X/veterinaria
17.
J Rheumatol ; 49(12): 1315-1319, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35970536

RESUMEN

OBJECTIVE: Examination and conventional radiography of joints are unable to precisely evaluate and measure disease activity in rheumatoid arthritis (RA). We quantified joint inflammation using 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in people with RA to determine if PET-derived uptake variables were correlated with RA disease activity measures. METHODS: We cross-sectionally studied 34 patients with RA in a substudy of the Rheumatoid Arthritis Study of the Myocardium (RHYTHM). All patients underwent 18F-FDG-PET scanning with CT for attenuation correction and anatomic co-registration. Linear regression was used to model the associations of disease activity scores with articular FDG uptake, calculated as standardized uptake values (SUVs). Weighted joint volume SUVs (wjSUV) representing 25%, 50%, 75%, and maximum (100%) uptake (wj25SUV, wj50SUV, wj75SUV, and wjMaxSUV, respectively) were calculated as global variables of the total volume of joint inflammation in each patient. RESULTS: Calculated wj25SUV (Spearman ρ = 0.39, P = 0.04), wj50SUV (ρ = 0.39, P = 0.04), and wj75SUV (ρ = 0.37, P = 0.045) measures were significantly correlated with the number of swollen joints. Similar significant correlations were found for the Simplified Disease Activity Index but not Clinical Disease Activity or Disease Activity Score in 28 joints. No associations were found between articular FDG uptake and nonarticular RA-related variables (ie, disease duration, seropositivity, or RA treatments). CONCLUSION: Articular FDG uptake in patients with RA was significantly correlated with the number of swollen joints but not with biochemical measures of inflammation.


Asunto(s)
Artritis Reumatoide , Fluorodesoxiglucosa F18 , Humanos , Artritis Reumatoide/diagnóstico por imagen , Artritis Reumatoide/complicaciones , Articulaciones/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Inflamación/complicaciones
19.
Reumatol. clín. (Barc.) ; 18(4): 191-199, Abr 2022. tab
Artículo en Español | IBECS | ID: ibc-204811

RESUMEN

Antecedentes: La espondiloartritis axial es una enfermedad reumatológica que afecta a individuos jóvenes y tiene una gran repercusión sociolaboral. El retraso en el diagnóstico y el tratamiento se asocia con un mayor deterioro funcional y un impacto negativo en la calidad de vida, por lo que requiere un abordaje multidisciplinario. Objetivo: Desarrollar y formular un conjunto de recomendaciones específicas basadas en la mejor evidencia disponible para la detección temprana, el diagnóstico, el tratamiento y el seguimiento de los pacientes adultos con espondiloartritis axial. Métodos: Se configuró un grupo desarrollador, se formularon preguntas clínicas contestables, se graduaron los desenlaces y se realizó la búsqueda sistemática de la evidencia. El panel de la guía fue multidisciplinario (incluyendo representantes de los pacientes) y balanceado, minimizando el sesgo por conflictos de intereses. Se utilizó la aproximación Grading of Recommendations Assessment, Development and Evaluation (GRADE) para evaluar la calidad de la evidencia, al igual que la dirección y la fortaleza de las recomendaciones. Se presentan 11 recomendaciones relacionadas con diagnóstico (n=2), tratamiento farmacológico (n=6), tratamiento no farmacológico (n=2) y seguimiento (n=1). Resultados: Se recomienda la radiografía de articulaciones sacroilíacas como primer método diagnóstico y el uso de escalas de actividad para el seguimiento de los pacientes (ASDAS o BASDAI). Los antiinflamatorios no esteroideos son la primera opción de tratamiento; en caso de intolerancia o dolor residual se recomienda acetaminofén u opioides. En pacientes con compromiso axial se recomienda abstenerse de utilizar medicamentos antirreumáticos modificadores de la enfermedad convencionales ni glucocorticoides sistémicos o locales. En pacientes con fallo a los antiinflamatorios no esteroideos, se recomienda un anti-TNF-α o un anti-IL-17A.(AU)


Background: Axial spondyloarthritis is a rheumatic condition affecting young patients with social and occupational consequences. Diagnosis delay is associated with functional impairment and impact on quality of life, requiring a multidisciplinary approach.ObjectiveTo develop a set of recommendations based on the best available evidence for the early detection, diagnosis, treatment, and monitoring of adult patients with axial spondyloarthritis. Methods: A working group was established, questions were developed, outcomes were graded, and a systematic search for evidence was conducted. A multidisciplinary panel of members was established (including patient representatives), minimizing bias in relation to conflicts of interest. The GRADE approach Grading of Recommendations Assessment, Development and Evaluation was used to assess the quality of the evidence as well as the direction and strength of recommendations. In total, 11 recommendations on diagnosis (n=2), pharmacological treatment (n=6), non-pharmacological treatment (n=2) and monitoring (n=1) are presented. Results: Sacroiliac joint radiography as the first diagnostic method, and the use of disease activity scales for patient monitoring (ASDAS or BASDAI), are recommended. Nonsteroidal anti-inflammatory drugs are the first treatment option; in case of intolerance or residual pain, acetaminophen or opioids are recommended. In patients with axial involvement, it is recommended not to use conventional disease-modifying antirheumatic drugs or systemic or local glucocorticoids. In patients with failure to non-steroidal anti-inflammatory drugs, anti-TNF or anti-IL17A is recommended. In those patients presenting with anti-TNF failure, starting an anti-IL17A is recommended. Exercise, physical and occupational therapy are recommended as part of treatment. It is recommended not to use unconventional therapies as the only treatment option.(AU)


Asunto(s)
Humanos , Espondiloartritis/diagnóstico , Espondiloartritis/tratamiento farmacológico , Espondiloartritis/prevención & control , Colombia , Calidad de Vida , Articulaciones/diagnóstico por imagen , Resultado del Tratamiento , Quimioterapia , Reumatología
20.
Rheumatology (Oxford) ; 61(10): 3997-4005, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-35104308

RESUMEN

OBJECTIVE: To explore the spectrum of articular and peri-articular ultrasound (US) findings at metacarpophalangeal (MCP) joints in calcium pyrophosphate (CPP) deposition disease (CPPD). METHODS: Consecutive CPPD patients (chronic CPP crystal inflammatory arthritis or OA with CPPD), and age- and sex-matched controls with RA were prospectively enrolled. Patients underwent bilateral US examination of MCP joints. CPP deposits, synovial inflammation, osteophytes, cartilage damage and bone erosions were recorded. RESULTS: Sixty CPPD patients (33, 55.0% with OA with CPPD and 27, 45.0% with chronic CPP crystal inflammatory arthritis) and 40 RA patients were enrolled. CPP deposits were detected in 24 (40.0%) CPPD patients and in 3 (7.5%) RA patients (P <0.01). In CPPD patients, different types of CPP deposits were identified at MCP joints: 17 (28.3%) patients had dorsal capsuloligamentous deposits, 14 (23.3%) intra-cartilaginous deposits, 13 (21.7%) lateral capsuloligamentous deposits, 12 (20.0%) intra-articular deposits, eight (13.3%) double contour sign and five (8.3%) flexor digitorum tendons' deposits. CPPD patients with chronic CPP crystal inflammatory arthritis showed more US findings indicating synovial inflammation and CPP deposits than those with OA with CPPD. Conversely, a higher prevalence of US features indicating structural damage was noted in this latter phenotype. CPP deposits and bone erosions were the US findings with the highest value for diagnosing chronic CPP crystal inflammatory arthritis and RA, respectively. CONCLUSION: This study provides pictorial evidence of the broad spectrum of US findings indicating CPP deposits at MCP joints in CPPD. Furthermore, we reported different US patterns in different CPPD phenotypes.


Asunto(s)
Condrocalcinosis , Pirofosfato de Calcio , Condrocalcinosis/diagnóstico por imagen , Humanos , Inflamación , Articulaciones/diagnóstico por imagen , Articulación Metacarpofalángica/diagnóstico por imagen , Tendones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...