Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.251
Filtrar
1.
Lakartidningen ; 1212024 Apr 09.
Artículo en Sueco | MEDLINE | ID: mdl-38595090

RESUMEN

In elderly patients high-degree atrioventricular (AV) block is often due to irreversible degeneration of the cardiac conduction system. Reversible causes must however be excluded prior to pacemaker implantation. In younger patients reversible causes are more likely, as well as more unusual etiologies. Lyme carditis is a rare, but reversible cause of AV block. It is a manifestation of Lyme borreliosis - an infectious disease caused by the bacteria Borrelia burgdorferi. Lyme carditis should particularly be considered in young and middle-aged patients with a high-degree AV block. When pretest probability is intermediate to high, a positive serological test makes the diagnosis of Lyme carditis highly likely. In these cases antibiotic treatment may revert the conduction disturbance, thus preventing unnecessary implantation of a permanent pacemaker.


Asunto(s)
Bloqueo Atrioventricular , Enfermedad de Lyme , Miocarditis , Persona de Mediana Edad , Humanos , Anciano , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Miocarditis/diagnóstico , Diagnóstico Diferencial , Enfermedad de Lyme/diagnóstico , Antibacterianos/uso terapéutico , Electrocardiografía
2.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38564374

RESUMEN

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Adulto Joven , Adulto , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Estimulación Cardíaca Artificial/métodos , Marcapaso Artificial/efectos adversos , Sistema de Conducción Cardíaco , Ventrículos Cardíacos , Resultado del Tratamiento
4.
J Am Heart Assoc ; 13(9): e032777, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38639357

RESUMEN

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.


Asunto(s)
Estenosis de la Válvula Aórtica , Bloqueo de Rama , Estimulación Cardíaca Artificial , Electrocardiografía , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Anciano de 80 o más Años , Anciano , Estimulación Cardíaca Artificial/efectos adversos , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Factores de Riesgo , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Tiempo , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Complicaciones Posoperatorias/diagnóstico , Recurrencia
5.
Sci Rep ; 14(1): 7825, 2024 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-38570621

RESUMEN

Diagnosing cardiac sarcoidosis (CS), especially in isolated cases, is challenging, particularly due to the limitations of endomyocardial biopsy, leading to potential undiagnosed cases in pacemaker-implanted patients. This study aims to provide real world findings to support new guideline for CS using 18F-fluoro-deoxyglucose positron-emission tomography computed tomography (FDG-PET/CT) which give a definite diagnosis of isolated CS (iCS) without histological findings. We examined consecutive patients with cardiac pacemakers for atrioventricular block (AV-b) attending our outpatient pacemaker clinic. The patients underwent periodical follow-up echocardiography and were divided into two groups according to echocardiographic findings: those with suspected CS and those without suspected CS. Patients suspected of having nonischemic cardiomyopathy underwent FDG-PET/CT for CS diagnosis. We investigated the utility of the new guideline for CS using FDG-PET/CT. Among the 272 patients enrolled, 97 patients were implanted with cardiac pacemakers for AV-b. Twenty-two patients were suspected of having CS during a median observation period of 5.4 years after pacemaker implantation. Of these, one did not consent, and nine of 21 cases (43%) were diagnosed with definite CS according to the new guidelines. Five of these nine patients were diagnosed with iCS using FDG-PET/CT. The number of patients diagnosed with definite CS using the new guidelines tended to be approximately 2.3 times that of the conventional criteria (p = 0.074). Three of the nine patients underwent steroid treatment. The composite outcome, comprising all-cause death, heart failure hospitalization, and a substantial reduction in left ventricular ejection fraction, were significantly lower in patients receiving steroid treatment compared to those without steroid treatment (p = 0.048). The utilization of FDG-PET/CT in accordance with the new guidelines facilitates the diagnosis of CS, including iCS, resulting in approximately 2.3 times as many diagnoses of CS compared to the conventional criteria. This guideline has the potential to support the early identification of iCS and may contribute to enhancing patient clinical outcomes.


Asunto(s)
Bloqueo Atrioventricular , Cardiomiopatías , Miocarditis , Sarcoidosis , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Fluorodesoxiglucosa F18 , Bloqueo Atrioventricular/diagnóstico por imagen , Bloqueo Atrioventricular/terapia , Volumen Sistólico , Radiofármacos , Tomografía de Emisión de Positrones/métodos , Función Ventricular Izquierda , Cardiomiopatías/patología , Sarcoidosis/diagnóstico por imagen , Sarcoidosis/patología , Esteroides , Estudios Retrospectivos
6.
Medicina (Kaunas) ; 60(3)2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38541230

RESUMEN

Background and Objectives: Atrioventricular (AV) dyssynchrony as well as atrial and ventricular pacing affect left atrial (LA) function. We conducted a study evaluating the effect of atrial and ventricular pacing on LA morphological and functional changes after dual-chamber pacemaker implantation. Materials and Methods: The study prospectively enrolled 121 subjects who had a dual-chamber pacemaker implanted due to sinus node disease (SND) or atrioventricular block (AVB). Subjects were divided into three groups based on indication and pacemaker programming: (1) SND DDDR 60; (2) AVB DDD 60 and (3) AVB DDD 40. Subjects were invited to one- and three-month follow-up visits. Three subsets based on pacing burden were analyzed: (1) high atrial (A) low ventricular (V); (2) high A, high V and (3) low A, high V. LA function was assessed from volumetric parameters and measured strains from echocardiography. Results: The high A, low V group consisted of 38 subjects; while high A, high V had 26 and low A, high V had 23. A significant decrease in reservoir and contractile LA strain parameters were only observed in the high A, low V pacing group after three months (reservoir 25.9 ± 10.3% vs. 21.1 ± 9.9%, p = 0.003, contractile -14.0 ± 9.0% vs. -11.1 ± 7.8, p = 0.018). While the re-established atrioventricular synchrony in the low A, high V group maintained reservoir LA strain at the baseline level after three months (21.4 ± 10.4% vs. 22.5 ± 10.4%, p = 0.975); in the high A, high V group, a further trend to decrease was noted (20.3 ± 8.9% vs. 18.7 ± 8.3%, p = 0.231). Conclusions: High atrial pacing burden independently of atrioventricular dyssynchrony and ventricular pacing impairs LA functional and morphological parameters. Changes appear soon after pacemaker implantation and are maintained.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Estimulación Cardíaca Artificial/efectos adversos , Atrios Cardíacos , Síndrome del Seno Enfermo/terapia , Bloqueo Atrioventricular/terapia
7.
Pacing Clin Electrophysiol ; 47(5): 635-641, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38552167

RESUMEN

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.


Asunto(s)
Marcapaso Artificial , Humanos , Masculino , Femenino , Estudios Retrospectivos , Niño , Preescolar , Electrodos Implantados , Bloqueo Atrioventricular/terapia , Síndrome del Seno Enfermo/terapia
8.
Europace ; 26(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38449430

RESUMEN

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Arritmias Cardíacas/terapia , Frecuencia Cardíaca/fisiología
9.
Pediatr Cardiol ; 45(4): 759-769, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38427091

RESUMEN

Postoperative atrioventricular block may occur after pediatric cardiac surgery. A small proportion of those who develop atrioventricular block will require pacemaker placement. The primary aim of this study was to determine factors associated with postoperative atrioventricular block. Secondary aims included determining factors associated with pacemaker placement in those with atrioventricular block. Data from the PHIS data were utilized to identify patients under 18 years of age who underwent cardiac surgery. Those who did and did not develop atrioventricular block. Univariable analyses and regression analyses were conducted to determine factors associated with postoperative atrioventricular block. Similar analyses were conducted to determine factors associated with pacemaker placement in those with atrioventricular block. A total of 43,716 admissions were identified. Of these, 2093 (5%) developed atrioventricular block and 480 (1% of total admissions) underwent pacemaker placement. Approximately 70% of those with atrioventricular block received steroids but this was not associated with a decrease in pacemaker placement. Risk factors (congenital malformations of the heart, comorbidities, medications) associated with increased risk of atrioventricular block and pacemaker placement were identified. Postoperative atrioventricular block occurred in 5% of pediatric admissions for cardiac surgery. Of these admissions with postoperative atrioventricular block, 23% required pacemaker placement. Isoproterenol and steroids were not associated with a reduction in the likelihood of pacemaker placement.


Asunto(s)
Bloqueo Atrioventricular , Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Marcapaso Artificial , Niño , Humanos , Adolescente , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Marcapaso Artificial/efectos adversos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cardiopatías Congénitas/complicaciones , Complicaciones Posoperatorias/etiología , Esteroides
10.
Open Heart ; 11(1)2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38538064

RESUMEN

OBJECTIVE: Transthyretin amyloid cardiomyopathy (ATTR-CM) is an infiltrative cardiac disorder caused by deposition of wild type or mutated transthyretin. As ATTR-CM is associated with conduction disease, we sought to determine its prevalence in patients with idiopathic high-degree atrioventricular (AV) block requiring permanent pacemaker (PPM) implantation. METHODS: Consecutive patients aged 70-85 years undergoing PPM implantation for idiopathic high-degree AV block between November 2019 and November 2021 were offered a 3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scan. Demographics, comorbidities, electrocardiographic and imaging data from the time of device implantation were retrospectively collected. RESULTS: 39 patients (79.5% male, mean (SD) age at device implantation 76.2 (2.9) years) had a DPD scan. 3/39 (7.7%, all male) had a result consistent with ATTR-CM (Perugini grade 2 or 3). Mean (SD) maximum wall thickness of those with a positive DPD scan was 19.0 mm (3.6 mm) vs 11.4 mm (2.7 mm) in those with a negative scan (p=0.06). All patients diagnosed with ATTR-CM had spinal canal stenosis and two had carpal tunnel syndrome. CONCLUSIONS: ATTR-CM should be considered in older patients requiring permanent pacing for high-degree AV block, particularly in the presence of left ventricular hypertrophy, carpal tunnel syndrome or spinal canal stenosis.


Asunto(s)
Amiloidosis , Bloqueo Atrioventricular , Síndrome del Túnel Carpiano , Humanos , Masculino , Anciano , Femenino , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/terapia , Estudios Retrospectivos , Prevalencia , Prealbúmina , Síndrome del Túnel Carpiano/complicaciones , Constricción Patológica/complicaciones
11.
J Cardiovasc Electrophysiol ; 35(5): 906-915, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38433355

RESUMEN

INTRODUCTION: Right ventricular (RV) pacing sometimes causes left ventricular (LV) systolic dysfunction, also known as pacing-induced cardiomyopathy (PICM). However, the association between specifically paced QRS morphology and PICM development has not been elucidated. This study aimed to investigate the association between paced QRS mimicking a complete left bundle branch block (CLBBB) and PICM development. METHODS: We retrospectively screened 2009 patients who underwent pacemaker implantation from 2010 to 2020 in seven institutions. Patients who received pacemakers for an advanced atrioventricular block or bradycardia with atrial fibrillation, baseline LV ejection fraction (LVEF) ≥ 50%, and echocardiogram recorded at least 6 months postimplantation were included. The paced QRS recorded immediately after implantation was analyzed. A CLBBB-like paced QRS was defined as meeting the CLBBB criteria of the American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society in 2009. PICM was defined as a ≥10% LVEF decrease, resulting in an LVEF of <50%. RESULTS: Among the 270 patients analyzed, PICM was observed in 38. Baseline LVEF was lower in patients with PICM, and CLBBB-like paced QRS was frequently observed in PICM. Multivariate analysis revealed that low baseline LVEF (odds ratio [OR]: 0.93 per 1% increase, 95% confidence interval [CI]: 0.89-0.98, p = 0.006) and CLBBB-like paced QRS (OR: 2.69, 95% CI: 1.25-5.76, p = 0.011) were significantly associated with PICM development. CONCLUSION: CLBBB-like paced QRS may be a novel risk factor for PICM. RV pacing, which causes CLBBB-like QRS morphology, may need to be avoided, and patients with CLBBB-like paced QRS should be followed-up carefully.


Asunto(s)
Potenciales de Acción , Bloqueo de Rama , Estimulación Cardíaca Artificial , Cardiomiopatías , Electrocardiografía , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Volumen Sistólico , Función Ventricular Izquierda , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Bloqueo Atrioventricular/etiología , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Bloqueo de Rama/etiología , Estimulación Cardíaca Artificial/efectos adversos , Cardiomiopatías/fisiopatología , Cardiomiopatías/etiología , Cardiomiopatías/terapia , Cardiomiopatías/diagnóstico , Diagnóstico Diferencial , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Derecha
12.
J Cardiovasc Electrophysiol ; 35(4): 846-847, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38348495

RESUMEN

The year 2024 marks the centenary of Mobitz's description of type II second-degree atrioventricular block. Its definition remains valid to this day with only minor modification for the diagnosis of infranodal conduction block. Mobitz a century ago indicated that his type II atrioventricular block was associated with Stock-Adams attacks and a prolonged duration of the QRS complex before the eventual description of bundle branch block.


Asunto(s)
Bloqueo Atrioventricular , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Electrocardiografía , Bloqueo de Rama/diagnóstico , Fascículo Atrioventricular
13.
J Am Heart Assoc ; 13(4): e032223, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38348803

RESUMEN

BACKGROUND: Screening for atrial fibrillation (AF) may reveal incidental arrhythmias of relevance. The aim of this study was to describe incidental arrhythmias detected during screening for AF in the STAR-FIB (Predicting SilenT AtRial FIBrillation in Patients at High Thrombembolic Risk) cohort study. METHODS AND RESULTS: In the STAR-FIB cohort study, we screened hospitalized patients for AF with 3 repeat 7-day Holter ECGs. We analyzed all Holter ECGs for the presence of the following incidental arrhythmias: (1) sinus node dysfunction, defined as sinus pause of ≥3 seconds' duration; (2) second-degree (including Wenckebach) or higher-degree atrioventricular block (AVB); (3) sustained supraventricular tachycardia of ≥30 seconds' duration; and (4) sustained ventricular tachycardia of ≥30 seconds' duration. We furthermore report treatment decisions because of incidental arrhythmias. A total of 2077 Holter ECGs were performed in 794 patients (mean age, 74.7 years; 49% women), resulting in a mean cumulative duration of analyzable ECG signal of 414±136 hours/patient. We found incidental arrhythmias in 94 patients (11.8%). Among these were sinus node dysfunction in 14 patients (1.8%), AVB in 41 (5.2%), supraventricular tachycardia in 42 (5.3%), and ventricular tachycardia in 2 (0.3%). Second-degree AVB was found in 23 patients (2.9%), 2:1 AVB in 10 (1.3%), and complete AVB in 8 (1%). Subsequently, 8 patients underwent pacemaker implantation, 1 for sinus node dysfunction (post-AF conversion pause of 9 seconds) and 7 for advanced AVB. One patient had an implantable cardioverter-defibrillator implanted for syncopal ventricular tachycardia. CONCLUSIONS: Incidental arrhythmias were frequently detected during screening for AF in the STAR-FIB study and resulted in device therapy in 1.1% of our cohort patients.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Desfibriladores Implantables , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Femenino , Anciano , Masculino , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Electrocardiografía Ambulatoria , Estudios de Cohortes , Síndrome del Seno Enfermo , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/terapia , Taquicardia Supraventricular/diagnóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/etiología , Hospitales
14.
BMJ Case Rep ; 17(1)2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38199649

RESUMEN

Dengue is a viral disease that clinically presents with fever, thrombocytopenia-related haemorrhagic complications and shock in its severest form. This female patient in her 40s primarily presented to the emergency department of the cardiac centre as syncopal attacks with a complete atrioventricular block. Temporary cardiac pacing as an emergency procedure helped to maintain cardiac rhythm and haemodynamics. A history of recent onset fever helped us to suspect and confirmed by serology for dengue pathology. Normal sinus rhythm was restored after 2 days, and we removed the temporary pacing. Cardiac arrhythmia did not recur in 6 months of follow-up. The aetiology for dengue-related cardiac arrhythmia is still not established. In the recovery phase from fever, complete heart block may show up as a primary presentation in the emergency. Its timely diagnosis and temporary pacing may allow spontaneous recovery. The inclusion of electrocardiography in dengue patient guidelines should help clinicians to dictate its treatment.


Asunto(s)
Bloqueo Atrioventricular , Dengue , Femenino , Adulto , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Trastorno del Sistema de Conducción Cardíaco , Corazón , Electrocardiografía , Fiebre , Dengue/complicaciones , Dengue/diagnóstico
15.
Future Cardiol ; 20(1): 21-25, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38223918

RESUMEN

Aim: Micra AV represents a leadless endocardial pacing system able to detect atrial contractions providing atrioventricular synchrony. A reduction of myocardial contractility may be detected in case of first-degree atrioventricular block (AVB). Materials & methods: In six patients with first-degree AVB (PQ interval ≥220 msec) was evaluated the left ventricle global longitudinal strain (LV GLS) by speckle tracking (ST) echocardiography during single-lead atrial sensing ventricular pacing (VDD) stimulation as compared with spontaneous rhythm (SR), 24-48 h after Micra AV implantation. Results: A statistically significant difference between the two modalities was observed (LV GLS during SR: -14.7% [interquartile range (IQR) 5.5], LV GLS during VDD pacing: -16.1% [IQR 5.2]; p value = 0.041). Conclusion: Our preliminary results suggest an improvement of myocardial contractility with VDD pacing as compared with SR.


What is this article about? The Micra AV is an electronic device placed in the heart chambers capable to supply the electrical activity of the heart. A reduction of cardiac contractility may be observed in patients with electrical disorders of the heart. What were the results? In six patients affected by electrical cardiac disorders, we observed an improvement of cardiac contractility using Micra AV as compared with the spontaneous electrical activity of the heart. What do the results of the study mean? The results of this study suggest that in patients carrying this electronic device should be preferred a specific modality of activation of the device as compared with the spontaneous electrical activity of the heart in order to improve the contractility of the cardiac walls.


Asunto(s)
Bloqueo Atrioventricular , Defectos de los Tabiques Cardíacos , Marcapaso Artificial , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Estimulación Cardíaca Artificial/métodos , Bloqueo Atrioventricular/terapia , Atrios Cardíacos/diagnóstico por imagen
16.
BMC Cardiovasc Disord ; 24(1): 77, 2024 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-38281925

RESUMEN

BACKGROUND: New-generation self-expanding valves can improve the success rate of transcatheter aortic valve replacement (TAVR) for severe pure native aortic regurgitation (PNAR). However, predictors of new-onset conduction block post-TAVR using new-generation self-expanding valves in patients with PNAR remain to be established. Therefore, this study aimed to identify predictors of new-onset conduction block post-TAVR using new-generation self-expanding valves (VitaFlow Liberty™) in patients with PNAR. METHODS: In this retrospective cohort study, patients were categorized into pacemaker and non-pacemaker groups based on their need for new postoperative permanent pacemaker implantation (PPI). Based on the postoperative presence of either new-onset complete left bundle branch block (cLBBB) or high-grade atrioventricular block (AVB), patients were further classified into conduction disorder and non-conduction disorder groups. Laboratory, echocardiographic, computed tomography, preoperative and postoperative electrocardiography, and procedural and clinical data were collected immediately after TAVR and during hospitalization and compared between the groups. Multivariate logistic regression analysis was performed incorporating the significant variables from the univariate analyses. RESULTS: This study examined 68 consecutive patients with severe PNAR who underwent TAVR. In 20 patients, a permanent pacemaker was fitted postoperatively. Multivariate logistic regression analysis revealed an association between the need for postoperative PPI and preoperative complete right bundle branch block (cRBBB) or first-degree AVB, as well as a non-tubular left ventricular outflow tract (LVOT). In addition, valve implantation depth and angle of aortic root were independent predictors of new-onset cLBBB or high-grade AVB developing post-TAVR. The predictive value of valve implantation depth and angle of aortic root was further supported by receiver operating characteristic curve analysis results. CONCLUSIONS: In patients with PNAR undergoing TAVR using self-expanding valves, preoperative cRBBB or first-degree AVB and a non-tubular LVOT were indicators of a higher likelihood of PPI requirement. Moreover, deeper valve implantation depth and greater angle of aortic root may be independent risk factors for new-onset cLBBB or high-grade AVB post-TAVR. Valve implantation depth and angle of aortic root values may be used to predict the possibility of new cLBBB or high-grade AVB post-TAVR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Resultado del Tratamiento , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Marcapaso Artificial/efectos adversos , Arritmias Cardíacas , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
17.
BMC Cardiovasc Disord ; 24(1): 73, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267846

RESUMEN

BACKGROUND: The systemic immune-inflammation index (SII), based on white blood cell, neutrophil, and platelet counts, is a proposed marker of systemic inflammation and immune activation. This study aimed to explore the relationship between SII and complete atrioventricular block (CAVB) development in STEMI patients undergoing primary PCI. METHODS: We retrospectively analyzed data from 883 patients who underwent primary PCI for STEMI between January 2009 and December 2017. Patients were categorized into two groups based on CAVB development. SII levels were calculated from blood samples taken on admission. RESULTS: Of the included patients, 48 (5.03%) developed CAVB. SII was higher in patients with CAVB compared to those without CAVB (1370 [1050-1779]x109/L vs. 771 [427-1462] x109/L, p < 0.001). Multivariate analysis showed a significant positive correlation between SII and the risk of CAVB development (OR:1.0003, 95%CI:1.0001-1.0005, P = 0.044). The cut-off value for the SII in the estimation of CAVB was 1117.7 × 109/L (area under the ROC curve [AUC]: 0.714, 95% CI = 0.657-0.770 with a sensitivity of 70.8% and specificity of 65.6%, p < 0.001). CONCLUSION: This study showed a significant link between high SII levels and CAVB development in STEMI patients undergoing PCI. Our findings suggest that SII may be a valuable, routinely available, and inexpensive marker for identifying patients at increased risk of CAVB.


Asunto(s)
Bloqueo Atrioventricular , Intervención Coronaria Percutánea , Infarto del Miocardio con Elevación del ST , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Infarto del Miocardio con Elevación del ST/diagnóstico , Infarto del Miocardio con Elevación del ST/terapia , Inflamación/diagnóstico
18.
J Int Med Res ; 52(1): 3000605231223040, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38206211

RESUMEN

Atrioventricular block (AVB) is a rare cardiac manifestation of hyperthyroidism (HTH). The scientific literature contains multiple reports of AVB in patients with HTH, ranging from subclinical to overt HTH and even thyroid storm. However, much remains unknown about the true prevalence, clinical course, optimal management, and outcomes of AVB in patients with HTH. Such patients are possibly overtreated with pacemakers because of a lack of understanding that AVB might be secondary to the hyperthyroid state and thus reversible. This narrative review discusses the pathophysiology of AVB in patients with HTH in the context of the available evidence.


Asunto(s)
Bloqueo Atrioventricular , Hipertiroidismo , Humanos , Bloqueo Atrioventricular/complicaciones , Bloqueo Atrioventricular/terapia , Hipertiroidismo/complicaciones , Pacientes , Corazón
19.
Indian Heart J ; 76(1): 27-30, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38070672

RESUMEN

BACKGROUND: Single chamber atrial pacemaker should be sufficient for patients with sinus node dysfunction (SND) with normal atrioventricular (AV) conduction. However, most patients undergo dual chamber pacemaker implantation because of concern of new onset AV block. The annual incidence of new AV block has been reported from 0.6 to 4.4 % in various studies. OBJECTIVES: Our aim is to assess mode survival in sinus node dysfunction with normal AV conduction patients implanted with AAIR. METHODS: Patients who underwent single chamber atrial pacemaker implantation for SND with normal AV conduction between January 2014 and December 2021 were followed up for pacemaker device change, new onset AV block, bundle branch block, atrial fibrillation (AF), lead complications, reoperation and mortality rate. RESULTS: A total of 113 patients underwent single chamber atrial pacemaker implantation for SND during the study period. Mean age was 55.6 ± 12.7 years. During a mean follow up of 48.7 ± 24.9 months, none of the patients required pacemaker device change to VVIR/DDDR. Nine patients underwent reoperation, 5 for lead dislodgment, 1 for high threshold, 1 for pocket site erosion and 3 for pulse generator change. None developed AV block or AF with slow ventricular rate. Only 4 patients developed AF (3 paroxysmal,1 permanent). There were 3 deaths during follow up and none were sudden deaths. CONCLUSION: Single chamber atrial pacing is an acceptable mode of pacing in patients with SND in developing countries. Development of AV conduction abnormalities is rare in this relatively younger population.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Adulto , Persona de Mediana Edad , Anciano , Síndrome del Seno Enfermo/complicaciones , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Marcapaso Artificial/efectos adversos , Atrios Cardíacos , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología
20.
Cardiol Young ; 34(1): 218-220, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38037818

RESUMEN

Myocarditis is an inflammatory disease of the heart muscle that most commonly occurs after infectious diseases in childhood. The clinical picture of acute myocarditis ranges from asymptomatic infection to fulminant heart failure and sudden death (1). Most of the patients may present with nonspecific symptoms such as respiratory distress, chest pain, nausea, and vomiting (2). While rhythm abnormalities such as ventricular and supraventricular rhythm disorders can be observed in these patients, various degrees of atrioventricular blocks may rarely develop (3). In this article, we aimed to present a patient who developed second-degree, high-grade atrioventricular block after myocarditis and recovered completely after treatment.


Asunto(s)
Bloqueo Atrioventricular , Insuficiencia Cardíaca , Miocarditis , Humanos , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Miocarditis/complicaciones , Miocarditis/diagnóstico , Miocardio , Ventrículos Cardíacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...