Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 712
Filtrar
1.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241257169, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38769768

RESUMEN

Background: The purpose of this study was to investigate the effect of 3D-printed technology to repair glenoid bone defect on shoulder joint stability. Methods: The shoulder joints of 25 male cadavers were tested. The 3D-printed glenoid pad was designed and fabricated. The specimens were divided into 5 groups. Group A: no bone defect and the structure of the glenoid labrum and joint capsule was intact; Group B: Anterior inferior bone defect of the shoulder glenoid; Group C: a pad with a width of 2 mm was installed; Group D: a pad with a width of 4 mm was installed; Group E: a pad with a width of 6 mm was installed. This study measured the distance the humeral head moved forward at the time of glenohumeral dislocation and the maximum load required to dislocate the shoulder. Results: The shoulder joint stability and humerus displacement was significantly lower in groups B and C compared with group A (p < .05). Compared with group A, the stability of the shoulder joint of group D was significantly improved (p < .05). However, there was no significant difference in humerus displacement between groups D and A (p > .05). In addition, compared with group A, shoulder joint stability was significantly increased and humerus displacement was significantly decreased in group E (p < .05). Conclusion: The 3D-printed technology can be used to make the shoulder glenoid pad to perfectly restore the geometric shape of the shoulder glenoid articular surface. Moreover, the 3D-printed pad is 2 mm larger than the normal glenoid width to restore the initial stability of the shoulder joint.


Asunto(s)
Aleaciones , Cadáver , Impresión Tridimensional , Articulación del Hombro , Titanio , Humanos , Masculino , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Fenómenos Biomecánicos , Inestabilidad de la Articulación/cirugía , Inestabilidad de la Articulación/fisiopatología , Cavidad Glenoidea/cirugía , Diseño de Prótesis
3.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241254913, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38749489

RESUMEN

Different techniques have been described for glenoid fractures, there is still a need for safe and effective agents to promote outcomes. From January 2016 to April 2021, the clinical data of 17 patients with pulley type IA fractures treated by the V-shaped fixation technique under shoulder arthroscopy were retrospectively analyzed. Preoperative X-ray, CT, and MRI examinations were completed. The functional score of the shoulder joint, such as the visual analog scale (VAS), Constant score, and Modified Rowe score, was used to evaluate the preoperative and final follow-up clinical outcomes. The active shoulder range of motion (ROM) was also collected preoperatively and at the final postoperative follow-up. Accordingly, intraoperative and postoperative complications were also observed. The mean follow-up was 49.52 months (16-79 months). The patients' follow-up exams showed that shoulder joint flexion, abduction, external rotation, internal rotation, and pain were not significantly different from those of the contralateral side (p > .05). The mean Constant score was 83.52 (58-98), and the average Modified Rowe score was 94.29 (70-100). X-ray and CT films of all cases showed good healing without articular depression or steps. Three patients had traumatic arthritis, with VAS <3 pain. No postoperative complications, such as infections, nerve or vessel damage, or suture anchor problems occurred during the follow-up period. Using the Double-pull, V-shaped fixation technique can stabilize the reduction of glenoid fractures while reducing the possibility of bone destruction. It is a good solution and provides an opportunity to treat rotator cuff tears associated with the procedure.


Asunto(s)
Artroscopía , Fijación Interna de Fracturas , Humanos , Masculino , Artroscopía/métodos , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Adulto , Fijación Interna de Fracturas/métodos , Rango del Movimiento Articular , Cavidad Glenoidea/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/diagnóstico por imagen
4.
Mymensingh Med J ; 33(2): 334-340, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38557507

RESUMEN

This cross-sectional descriptive purposive study was conducted among 150 (70 right and 80 left) fully ossified dry human scapulae of Bangladeshi people from January 2019 to December 2019 in the Department of Anatomy, Mymensingh Medical College, Mymensingh. Shape of the glenoid cavity was observed as pear, oval or inverted comma shape. Morphometric parameters such as length and breadth of glenoid cavity were measured by digital Vernier slide calipers. In this study, 19.13% cases were found inverted comma shaped, 35.65% cases were oval and 45.22% cases were pear shaped. The mean±SD length of glenoid cavity was 37.5±3.61 mm and 36.19±3.68 mm on right and left sided scapulae respectively and mean±SD breadth was 23.6±2.73 mm on right and 23.42±2.75 mm on left side respectively. Mean±SD glenoid cavity index was 62.89±4.39 on right and 64.61±4.74 on left sided scapulae. Morphometric analysis of glenoid fossa of scapula might help clinicians in shoulder and its associated diseases.


Asunto(s)
Cavidad Glenoidea , Personas del Sur de Asia , Humanos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/anatomía & histología , Estudios Transversales , Escápula/anatomía & histología , Pueblo Asiatico
5.
J Craniomaxillofac Surg ; 52(5): 570-577, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38485626

RESUMEN

The aim of this study was to evaluate condylar and glenoid fossa remodeling after bimaxillary orthognathic surgery guided by patient-specific mandibular implants. In total, 18 patients suffering from dentofacial dysmorphism underwent a virtually planned bimaxillary mandibular PSI-guided orthognathic procedure. One month prior to surgery, patients underwent a CBCT scan and optical scans of the dental arches; these datasets were re-acquired 1 month and at least 9 months postsurgery. Three-dimensional models of the condyles, glenoid fossae, and interarticular surface space (IASS) were obtained and compared to evaluate the roto-translational positional discrepancy and surface variation of each condyle and glenoid fossa, and the IASS variation. The condylar position varied by an average of 4.31° and 2.18 mm, mainly due to surgically unavoidable ramus position correction. Condylar resorption remodeling was minimal (average ≤ 0.1 mm), and affected skeletal class III patients the most. Later condylar remodeling was positively correlated with patient age. No significant glenoid fossa remodeling was observed. No postoperative orofacial pain was recorded at clinical follow-up. The procedure was accurate in minimizing the shift in relationship between the bony components of the TMJ and their remodeling, and was effective in avoiding postoperative onset of orofacial pain. An increase in sample size, however, would be useful to confirm our findings.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Procedimientos Quirúrgicos Ortognáticos , Articulación Temporomandibular , Humanos , Femenino , Masculino , Adulto , Articulación Temporomandibular/diagnóstico por imagen , Articulación Temporomandibular/cirugía , Procedimientos Quirúrgicos Ortognáticos/métodos , Mandíbula/cirugía , Mandíbula/diagnóstico por imagen , Cóndilo Mandibular/diagnóstico por imagen , Cóndilo Mandibular/cirugía , Cóndilo Mandibular/patología , Adulto Joven , Remodelación Ósea/fisiología , Imagenología Tridimensional/métodos , Maxilar/cirugía , Maxilar/diagnóstico por imagen , Adolescente , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/patología , Cavidad Glenoidea/cirugía
6.
Sci Rep ; 14(1): 6500, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38499695

RESUMEN

Scapular surgery has usually been performed through the posterior Judet approach. This approach allows access to the entire posterior scapular body, but causes significant soft tissue damage and detaches the deltoid muscle. To date, there has been no clinical study of a deltoid-preserving approach to access the joint for displaced postero-inferior glenoid fractures (Ideberg type II or Ib). We describe an easy and less invasive approach to the postero-inferior glenoid fossa.


Asunto(s)
Fracturas Óseas , Cavidad Glenoidea , Humanos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Escápula/diagnóstico por imagen , Escápula/cirugía , Hombro/diagnóstico por imagen , Hombro/cirugía , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fijación Interna de Fracturas
7.
Int Orthop ; 48(4): 1057-1063, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38302596

RESUMEN

PURPOSE: The aim of the study reveals a new intuitive method for preoperatively assessing defect ratio in glenoid deficiency based on the native glenoid width and the bare spot. METHODS: A linear relationship, i.e. the rh formula, between the native glenoid width (2r) and height (h) was revealed by a cadaver cohort (n = 204). To validate the reliability of the rh formula, 280 3D-CT images of intact glenoids were recruited. To evaluate the accuracy of rh formula in estimating glenoid defect, the 65 anterior-inferior defect models were artificially established based on the 3D-CT images of intact glenoids. Moreover, a clinically common anterior-posterior (AP) method was compared with the rh formula, to verify the technical superiority of rh formula. RESULTS: The regression analysis indicated a linear relationship between the width and height of intact glenoid: 2r = 0.768 × h - 1.222 mm (R2 = 0.820, p < 0.001). An excellent reliability was found between the formula prediction and model width (ICC = 0.911, p = 0.266). An excellent agreement was found between the predicted values and model parameters (glenoid width, ICCrh = 0.967, prh = 0.778; defect ratio, prh = 0.572, ICCrh = 0.997). And, it is of higher accuracy compared to the AP method (glenoid width, ICCAP = 0.933, pAP = 0.001; defect ratio, ICCAP = 0.911, pAP = 0.033). CONCLUSION: Applying the cadaver-based formula on 3D-CT scans accurately predicts native glenoid width and redefines bare spot for preoperatively determining glenoid bone loss.


Asunto(s)
Enfermedades Óseas Metabólicas , Cavidad Glenoidea , Inestabilidad de la Articulación , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Escápula/diagnóstico por imagen , Cadáver , Cavidad Glenoidea/diagnóstico por imagen
8.
J Shoulder Elbow Surg ; 33(5): 1058-1067, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37848155

RESUMEN

BACKGROUND: Angled bony-increased offset and metal-augmented baseplate have recently been used to achieve neutral to inferior inclination of the glenoid implant. Nonetheless, bone incorporation is difficult to evaluate using computed tomography or other conventional methods owing to the presence of metal artifacts; therefore, whether bone incorporation between the grafted bone and glenoid or between the graft and baseplate implant can be achieved remains unclear. Several studies have reported the effectiveness of tomosynthesis in reducing metal artifacts for the evaluation of implant loosening, bone resorption, and spot welds. We aimed to evaluate and compare the bone incorporation rates between angled bony-increased offset and metal-augmented implants using tomosynthesis with metal artifact reduction technology. We hypothesized that a high bone incorporation rate would be obtained with angled bony-increased offset and a metal-augmented baseplate. METHODS: A total of 52 patients who underwent reverse total shoulder arthroplasty (TSA) with angled bony-increased offset and 42 patients who underwent reverse total shoulder arthroplasty with metal-augmented baseplate were assessed and followed up for a minimum of 2 years. The bone incorporation and implant loosening rates were compared between the 2 groups, and the sites of spot welds and trabeculation were recorded according to zones. Bone incorporation between the bone and prosthesis was defined as a confirmation of spot welds connecting the porous area and bone in more than three zones. Bone incorporation between the native bone and grafted bone was defined as an observation of trabeculation. Glenoid loosening was defined as the presence of at least 1 mm radiolucency around the prosthesis in more than 2 zones. RESULTS: Both the angled bony-increased offset and metal-augmented baseplate groups achieved sufficient bone incorporation rates (98% [51/52 cases] vs. 100% [42/42 cases], P = 1.0) and low implant loosening rates (2% [1/52 cases] vs. 0% [0/42 cases], P = 1.0). Spot welds and trabeculation were likely to be confirmed in the lower parts of the glenoid. CONCLUSION: The two groups did not show any significant differences regarding bone incorporation rates. Considering the complexity of performing the procedure with angled bony-increased offset, the use of a metal-augmented baseplate can serve as an alternative treatment to avoid superior inclination in reverse total shoulder arthroplasty.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Escápula/diagnóstico por imagen , Escápula/cirugía , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
9.
J Shoulder Elbow Surg ; 33(2): e58-e67, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37506998

RESUMEN

BACKGROUND: Several techniques have been adopted during primary reverse shoulder arthroplasty (RSA) to manage glenoid bone defect. Among bone grafts, humeral head autograft is currently the mainstream option. However, autologous humeral heads may be unavailable or inadequate, and allografts may be a viable alternative. The aim of the present study was to evaluate the functional and radiologic outcomes of femoral head allografts for glenoid bone defects in primary RSA. METHODS: We conducted a retrospective study with prospective data collection enrolling 20 consecutive patients who underwent RSA with femoral head allografts for glenoid bone defects. Indications for surgery were eccentric cuff tear arthropathy in 10 cases (50%), concentric osteoarthritis in 9 cases (45%), and fracture sequelae in 1 case (5%). Each patient was evaluated preoperatively and at follow-up by radiologic and computed tomography (CT) and by assessing the range of motion (ROM) and the Constant-Murley score (CMS). A CT-based software, a patient-specific 3D model of the scapula, and patient-specific instrumentation were used to shape the graft and to assess the position of K-wire for the central peg. Postoperatively, CT scans were used to identify graft incorporation and resorption. RESULTS: After a median follow-up of 26.5 months (24-38), ROM and CMS showed a statistically significant improvement (all P = .001). The median measures of the graft were as follows: 28 mm (28-29) for diameter, 22° (10°-31°) for angle, 4 mm (2-8 mm) for minimum thickness, and 15 mm (11-21 mm) for maximum thickness. Before the surgery, the median glenoid version was 21.8° (16.5°-33.5°) for the retroverted glenoids and -13.5° (-23° to -12°) for the anteverted glenoids. At the follow-up, the median postoperative baseplate retroversion was 5.7° (2.2°-1.5°) (P = .001), and this value was close to the 4° retroversion planned on the preoperative CT-based software. Postoperative major complications were noted in 4 patients: 2 dislocations, 1 baseplate failure following a high-energy trauma, and 1 septic baseplate failure. Partial graft resorption without glenoid component failure was observed in 3 cases that did not require revision surgery. CONCLUSION: The femoral head allograft for glenoid bone loss in primary RSA restores shoulder function, with CMS values comparable to those of sex- and age-matched healthy individuals. A high rate of incorporation of the graft and satisfactory correction of the glenoid version can be expected after surgery. The management of glenoid bone defects remains a challenging procedure, and a 15% risk of major complication must be considered.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Cabeza Femoral/trasplante , Estudios Retrospectivos , Escápula/cirugía , Complicaciones Posoperatorias/etiología , Aloinjertos/cirugía , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Resultado del Tratamiento , Rango del Movimiento Articular
10.
J Shoulder Elbow Surg ; 33(2): 335-342, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37482247

RESUMEN

BACKGROUND: Glenoid bone loss is a known challenge in primary and revision reverse total shoulder arthroplasty. In severe deficiency, even placing the baseplate in alternative centerline or using an augmented baseplate may be insufficient. This study reports on the use of a soft tissue resurfacing technique using Achilles tendon allograft, coined Yoke procedure, for salvage treatment of glenoid deficient shoulder requiring reconstruction. MATERIALS AND METHODS: All patients who underwent the Yoke procedure between 2014 and 2020 by a single surgeon at a single academic center were identified and had their charts retrospectively reviewed. Demographics and surgical information were recorded. Preoperative X-rays and 3D-computed tomography scans were reviewed to classify patient glenoid types, evaluate glenoid medialization, and measure shoulder angles. Preoperative and postoperative range of motions and patient-reported outcome scores were evaluated, including anterior elevation, external rotation, internal rotation, visual analog scale, subjective shoulder value score, Simple Shoulder Test, and American Shoulder and Elbow Surgeons (ASES) scores. Postoperative radiographs and follow-up notes were reviewed to evaluate postoperative complication profiles at 1 year. RESULTS: Seven patients with a median age of 69 years (range, 54-77 years) underwent Yoke procedure and had a median 12-month follow-up (range, 9-56 months). All patients were female and had a median of 2 prior shoulder surgeries (range, 0-13). Of all the patients, the most common comorbidity was osteoporosis (6) followed by rheumatoid arthritis (3). Of the 5 patients who had previous arthroplasty, the most common indications were baseplate failure (4), followed by instability (3) and infection (3). The median visual analog scale score improved from 8 (range, 3-9) to 2 (range, 1-4). The median Simple Shoulder Test improved from 8% (range, 0%-42%) to 33% (range, 17%-83%). The median ASES score improved from 15 (range, 5-38) to 52 (range, 40-78). The median anterior elevation and external rotation improved from 20° (range, 0°-75°) to 100° (range, 40°-145°) and 10° (range, 0°-20°) to 20° (range, 0°-55°), respectively. There was no change in median internal rotation. As of the last follow-up, one patient reported postoperative complications of anterior-superior implant escape, heterotopic ossification, and scapular notching. CONCLUSION: The Yoke procedure is a promising salvage treatment that can offer patients consistent pain reduction and moderate functional improvements at short-term follow-up. In the setting of poor bone quality and severe glenoid deficiency, glenoid baseplate implantation may not be absolutely necessary for a pain-relieving, functionally acceptable outcome.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Femenino , Preescolar , Niño , Masculino , Artroplastía de Reemplazo de Hombro/efectos adversos , Articulación del Hombro/cirugía , Terapia Recuperativa/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Dolor , Rango del Movimiento Articular , Cavidad Glenoidea/cirugía
11.
J Shoulder Elbow Surg ; 33(2): 223-233, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37774830

RESUMEN

BACKGROUND: Traditional, commercially sourced patient-specific instrumentation (PSI) systems for shoulder arthroplasty improve glenoid component placement but can involve considerable cost and outsourcing delays. The purpose of this randomized controlled trial was to compare the accuracy of glenoid component positioning in anatomic total shoulder arthroplasty (aTSA) using an in-house, point-of-care, 3-dimensionally (3D) printed patient-specific glenoid drill guide vs. standard nonspecific instrumentation. METHODS: This single-center randomized controlled trial included 36 adult patients undergoing primary aTSA. Patients were blinded and randomized 1:1 to either the PSI or the standard aTSA guide groups. The primary endpoint was the accuracy of glenoid component placement (version and inclination), which was determined using a metal-suppression computed tomography scan taken between 6 weeks and 1 year postoperatively. Deviation from the preoperative 3D templating plan was calculated for each patient. Blinded postoperative computed tomography measurements were performed by a fellowship-trained shoulder surgeon and a musculoskeletal radiologist. RESULTS: Nineteen patients were randomized to the patient-specific glenoid drill guide group, and 17 patients were allocated to the standard instrumentation control group. There were no significant differences between the 2 groups for native version (P = .527) or inclination (P = .415). The version correction was similar between the 2 groups (P = .551), and the PSI group was significantly more accurate when correcting version than the control group (P = .042). The PSI group required a significantly greater inclination correction than the control group (P = .002); however, the 2 groups still had similar accuracy when correcting inclination (P = .851). For the PSI group, there was no correlation between the accuracy of component placement and native version, native inclination, or the Walch classification of glenoid wear (P > .05). For the control group, accuracy when correcting version was inversely correlated with native version (P = .033), but accuracy was not correlated with native inclination or the Walch classification of glenoid wear (P > .05). The intraclass correlation coefficient was 0.703 and 0.848 when measuring version and inclination accuracy, respectively. CONCLUSION: When compared with standard instrumentation, the use of in-house, 3D printed, patient-specific glenoid drill guides during aTSA led to more accurate glenoid component version correction and similarly accurate inclination correction. Additional research should examine the influence of proper component position and use of PSI on clinical outcomes.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Escápula/cirugía , Artroplastia , Tomografía Computarizada por Rayos X , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Imagenología Tridimensional/métodos
12.
J Shoulder Elbow Surg ; 33(4): 872-879, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37689103

RESUMEN

BACKGROUND: Current methods available for assessment of radiolucency and in-between fin (IBF) growth of a glenoid component have not undergone interobserver reliability testing for an all-polyethylene fluted central peg (FCP) glenoid. The purpose of this study was to evaluate anteroposterior radiographs of an FCP glenoid component at ≥48 months comparing commonly used scales to a new method adapted to the FCP. Our hypothesis was that the new method would result in acceptable intra- and interobserver agreement and a more accurate description of radiographic findings. METHODS: We reviewed ≥48-month follow-up radiographs of patients treated with a primary aTSA using an FCP glenoid. Eighty-three patients were included in the review. Radiographs were evaluated by 5 reviewers using novel IBF radiodensity and radiolucency assessments and the Wirth and Lazarus methods. To assess intraobserver reliability, a subset of 40 images was reviewed. Kappa statistics were calculated to determine intra- and interobserver reliability; correlations were assessed using Pearson correlation. RESULTS: Interobserver agreement (κ score) was as follows: IBF 0.71, radiolucency 0.68, Wirth 0.48, and Lazarus 0.22. Intraobserver agreement ranges were as follows: IBF radiodensity 0.36-0.67, radiolucency 0.55-0.62, Wirth 0.11-0.73, and Lazarus 0.04-0.46. Correlation analysis revealed the following: IBF to Wirth r = 0.93, radiolucency to Lazarus r = 0.92 (P value <.001 for all). CONCLUSION: This study introduces a radiographic assessment method developed specifically for an FCP glenoid component. Results show high interobserver and acceptable intraobserver reliability for the method presented in this study. The new scales provide a more accurate description of radiographic findings, helping to identify glenoid components that may be at risk for loosening.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Cavidad Glenoidea , Prótesis Articulares , Articulación del Hombro , Humanos , Polietileno , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastia de Reemplazo/métodos , Reproducibilidad de los Resultados , Estudios de Seguimiento , Resultado del Tratamiento , Diseño de Prótesis , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
13.
Int J Oral Maxillofac Surg ; 53(2): 133-140, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37442687

RESUMEN

This study aimed to characterize three-dimensional quantitative morphological changes of glenoid fossa in patients with skeletal Class III malocclusion treated with bimaxillary orthognathic surgery. Ninety-five eligible patients (50 male, 45 female; mean age 22.09 years) were enrolled retrospectively. Cone beam computed tomography obtained at 1 week preoperatively (T0), immediately after surgery (T1), and at ≥ 12 months postoperatively (T2) were registered based on cranial base using voxel-based registration in 3D Slicer. Glenoid fossa surface was divided spatially into four regions, and bone modelling in these regions was visualized with color maps. Our data revealed that the mean surface variations of glenoid fossa were small, with modest bone formation as a whole. No significant associations between anteroposterior or vertical mandibular displacement and overall glenoid fossa remodeling were found (P > 0.05). Moreover, bone deposition was frequently observed in the anterior-lateral region of glenoid fossa in patients with a larger mandibular movement during T0-T1 (P < 0.001). Paired bone formation in the anterior-lateral region of glenoid fossa and bone resorption in the anterior-lateral region of condylar head was frequently observed. Collectively, our results revealed that glenoid fossa underwent complex but modest bone remodeling after bimaxillary surgery in skeletal Class III patients.


Asunto(s)
Cavidad Glenoidea , Maloclusión de Angle Clase III , Cirugía Ortognática , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Cóndilo Mandibular/cirugía , Estudios Retrospectivos , Maloclusión de Angle Clase III/diagnóstico por imagen , Maloclusión de Angle Clase III/cirugía , Remodelación Ósea , Tomografía Computarizada de Haz Cónico/métodos
14.
J Shoulder Elbow Surg ; 33(5): 1177-1184, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37890765

RESUMEN

BACKGROUND: Mixed reality may offer an alternative for computer-assisted navigation in shoulder arthroplasty. The purpose of this study was to determine the accuracy and precision of mixed-reality guidance for the placement of the glenoid axis pin in cadaver specimens. This step is essential for accurate glenoid placement in total shoulder arthroplasty. METHODS: Fourteen cadaveric shoulders underwent simulated shoulder replacement surgery by 7 experienced shoulder surgeons. The surgeons exposed the cadavers through a deltopectoral approach and then used mixed-reality surgical navigation to insert a guide pin in a preplanned position and trajectory in the glenoid. The mixed-reality system used the Microsoft Hololens 2 headset, navigation software, dedicated instruments with fiducial marker cubes, and a securing pin. Computed tomography scans obtained before and after the procedure were used to plan the surgeries and determine the difference between the planned and executed values for the entry point, version, and inclination. One specimen had to be discarded from the analysis because the guide pin was removed accidentally before obtaining the postprocedure computed tomography scan. RESULTS: Regarding the navigated entry point on the glenoid, the mean difference between planned and executed values was 1.7 ± 0.8 mm; this difference was 1.2 ± 0.6 mm in the superior-inferior direction and 0.9 ± 0.8 mm in the anterior-posterior direction. The maximum deviation from the entry point for all 13 specimens analyzed was 3.1 mm. Regarding version, the mean difference between planned and executed version values was 1.6° ± 1.2°, with a maximum deviation in version for all 13 specimens of 4.1°. Regarding inclination, the mean angular difference was 1.7° ± 1.5°, with a maximum deviation in inclination of 5°. CONCLUSIONS: The mixed-reality navigation system used in this study allowed surgeons to insert the glenoid guide pin on average within 2 mm from the planned entry point and within 2° of version and inclination. The navigated values did not exceed 3 mm or 5°, respectively, for any of the specimens analyzed. This approach may help surgeons more accurately place the definitive glenoid component.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Realidad Aumentada , Cavidad Glenoidea , Articulación del Hombro , Cirugía Asistida por Computador , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastia de Reemplazo/métodos , Cirugía Asistida por Computador/métodos , Cadáver , Imagenología Tridimensional/métodos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
15.
J Shoulder Elbow Surg ; 33(4): 792-797, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37852431

RESUMEN

BACKGROUND: Total shoulder arthroplasty (TSA) aims to reconstruct the premorbid anatomy of a pathologic shoulder. A healthy contralateral shoulder could be useful as a template in planning TSA. The symmetry between the left and right shoulders in healthy patients remains to be proved. The purpose of this study was to compare the 3-dimensional anatomy of the glenoid between sides in a healthy population. METHODS: A multinational computed tomography scan database was retrospectively reviewed for all healthy bilateral shoulders in patients aged between 18 and 50 years. One hundred thirty pairs of healthy shoulder computed tomography scans were analyzed, and glenoid version, inclination, width, and height, as well as glenoid lateral offset and scapula lateral offset, were measured. All anatomic measures were computed with Blueprint, validated 3-dimensional planning software. The intraclass correlation coefficient was determined for each measure between left and right shoulders. The minimal detectable change (MDC) was calculated using the following formula: MDC=2×1.96×Standarderrorofmeasurement. RESULTS: The comparison between 130 pairs of healthy scapulae showed statistically significant differences in absolute values between right and left glenoid version (-5.3° vs. -4.6°, P < .01), inclination (8.4° vs. 9.3°, P < .01), and width (25.6 mm vs. 25.4 mm, P < .01), as well as scapula offset (105.8 mm vs. 106.2 mm, P < .01). Glenoid height was comparable between right and left shoulders (33.3 mm vs. 33.3 mm, P = .9). The differences between the means were always inferior to the MDC regarding glenoid version, inclination, height, and width, as well as scapula offset. Very strong intraclass correlation coefficients between the left and right shoulders were found for all evaluated paired measures. CONCLUSION: Healthy contralateral scapulae are highly reliable to predict inclination, height, width, and scapula offset and are reliable to predict version of a given scapula. Paired right and left scapulae were not statistically symmetrical regarding mean glenoid version, inclination, and width, as well as scapula offset. Nevertheless, the reported differences were not higher than the MDC for this cohort, confirming that healthy contralateral shoulders can be a useful template in TSA preoperative planning.


Asunto(s)
Cavidad Glenoidea , Articulación del Hombro , Humanos , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Hombro , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios Retrospectivos , Imagenología Tridimensional , Escápula/diagnóstico por imagen , Escápula/cirugía , Tomografía Computarizada por Rayos X , Cavidad Glenoidea/diagnóstico por imagen
16.
J Orthop Res ; 42(5): 923-933, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37997511

RESUMEN

B-type glenoids are characterized by posterior humeral head migration and/or bony-erosion-induced glenoid retroversion. Patients with this type of osteoarthritic glenoids are known to be at increased risk of glenoid component loosening after anatomic total shoulder arthroplasty (aTSA). One of the main challenges in B glenoid surgical planning is to find a balance between correcting the bony shape and maintaining the quality of the bone support. This study aims to systematically quantify variabilities in terms of scapular morphology and bone mineral density in patients with B glenoids and to identify patterns of covariation between these two features. Using computed tomography scan images of 62 patients, three-dimensional scapular surface models were constructed. Rigid and nonrigid surface registration of the scapular surfaces, followed by volumetric registration and material mapping, enabled us to develop statistical shape model (SSM) and statistical density model (SDM). Partial least square correlation (PLSC) was used to identify patterns of covariation. The developed SSM and SDM represented 85.9% and 56.6% of variabilities in terms of scapular morphology and bone density, respectively. PLSC identified four modes of covariation, explaining 66.0% of the correlation between these two variations. Covariation of posterior-inferior glenoid erosion with posterior sclerotic bone formation in association with reduction of bone density in the anterior and central part of the glenoid was detected as the primary mode of covariation. Identification of these asymmetrical distribution of bone density can inform us about possible reasons behind glenoid component loosening in B glenoids and surgical guidelines in terms of the compromise between bony shape correction and bone support quality.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Osteoartritis , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Densidad Ósea , Osteoartritis/diagnóstico por imagen , Osteoartritis/cirugía , Escápula/diagnóstico por imagen , Escápula/cirugía , Cavidad Glenoidea/cirugía , Estudios Retrospectivos
17.
Eur J Orthop Surg Traumatol ; 34(2): 1045-1056, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37898968

RESUMEN

BACKGROUND: Augmented glenoid baseplate and offset humeral tray reverse total shoulder arthroplasty (RTSA) implants may decrease the mechanical impingement that creates scapular notching and improve shoulder function. This study evaluated the clinical efficacy of three different RTSA glenoid baseplate and offset humeral tray combinations for patient-reported shoulder function, pain and instability, radiographic imaging evidence of glenoid baseplate or humeral stem subsidence and migration, bony changes associated with implant loosening, and scapular notching over the initial 2 years post-RTSA. Primary outcomes included active shoulder mobility, perceived function, pain, instability, scapular notching, and implant survival. METHODS: Sixty-seven patients from 6 research sites received one of three different glenoid baseplate and humeral tray combinations. Group 1 (n = 21) received a mini-augmented glenoid baseplate with a standard humeral tray; Group 2 (n = 23) received a standard glenoid baseplate and a mini-humeral tray with 3 trunnion offset options; Group 3 (n = 23) received both a mini-augmented glenoid baseplate and a mini-humeral tray with 3 trunnion offset options. Subjects underwent radiologic evaluation, completed the ASES scale, the EQ-5D-5L quality of life scale, VAS shoulder pain and instability questions, and active shoulder mobility measurements pre-operatively, and 6-weeks, 6-months, 1-2 years post-RTSA. RESULTS: Improved active shoulder mobility, quality of life, perceived function, decreased shoulder pain and instability, excellent implant survival and minimal scapular notching were observed for all groups. Group 3 had better overall active shoulder mobility than the other groups and better perceived function than Group 1. CONCLUSION: The group that received the mini-augmented glenoid baseplate and mini-humeral tray combination had better overall active shoulder flexion, external rotation at 90° abduction, and internal rotation. This group also had better perceived shoulder function compared to the group that received a mini-augmented glenoid baseplate with a standard humeral tray.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Prótesis Articulares , Articulación del Hombro , Prótesis de Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Dolor de Hombro/cirugía , Calidad de Vida , Húmero/cirugía , Prótesis Articulares/efectos adversos , Resultado del Tratamiento , Rango del Movimiento Articular , Estudios Retrospectivos , Cavidad Glenoidea/cirugía
18.
J Shoulder Elbow Surg ; 33(1): 55-64, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37385424

RESUMEN

BACKGROUND: The success of traditional shoulder hemiarthroplasty (HA) with cobalt-chromium heads is limited by painful glenoid erosion with problematic bone loss. Hemiprostheses with pyrolytic carbon (PyC) heads have shown reduced glenoid erosion in experimental laboratory studies. Few in vivo data are available. METHODS: We performed a single-center consecutive cohort study of 31 of 34 patients (91%) who underwent PyC HA between September 2013 and June 2018. In 11 of these patients, concentric glenoid reaming was additionally performed. The mean follow-up period was 5.5 years (range, 3.5-7 years). Standardized radiographs were taken, and clinical function (Constant score) and pain (visual analog scale score) were recorded. Anteroposterior radiographs were analyzed according to an established method by 2 independent observers: A line parallel to the superior and inferior glenoid rim was translated to the most medial point of the glenoid surface. A further parallel line was placed on the spinoglenoid notch. The distance between these 2 lines was measured. Measurements were scaled using the known diameter of the implanted humeral head component. To assess eccentric erosion, anteroposterior and axial images were classified according to Favard and Walch, respectively. RESULTS: Mean medial glenoid erosion measured 1.4 mm at an average of 5.5 years of follow-up. In the first year, 0.8 mm of erosion was observed, significantly more than the average erosion per year of 0.3 mm (P < .001). Mean erosion per year was 0.4 mm in patients with glenoid reaming vs. 0.2 mm in those without reaming (P = .09). An evolution of glenoid morphology was observed in 6 patients, of whom 4 had a progression of the erosion grade. The prosthesis survival rate was 100%. The Constant score improved from 45.0 preoperatively to 78.0 at 2-3 years postoperatively and 78.8 at latest follow-up (5.5 years postoperatively) (P < .001). The pain score on a visual analog scale decreased from 6.7 (range, 3-9) preoperatively to 2.2 (range, 0-8) at latest follow-up (P < .001). There was a weak correlation (r = 0.37) between erosion and pain improvement (P = .039) and no correlation between erosion and change in Constant score (r = 0.06). CONCLUSION: PyC HA caused little glenoid erosion and a sustained improvement in clinical function in our cohort at mid-term follow-up. PyC demonstrates a biphasic development of glenoid erosion, with a reduced rate after the first year. PyC HA should therefore be considered as an alternative to cobalt-chromium HA and to anatomical total shoulder arthroplasty for patients with a high risk of glenoid component complications.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cavidad Glenoidea , Articulación del Hombro , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios de Seguimiento , Estudios de Cohortes , Dolor , Cromo , Cobalto , Resultado del Tratamiento , Estudios Retrospectivos , Cavidad Glenoidea/cirugía , Rango del Movimiento Articular
19.
JBJS Rev ; 11(10)2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096492

RESUMEN

¼ Treatment of glenoid bone loss continues to be a challenge in total shoulder arthroplasty (TSA). Although correcting glenoid wear to patient's native anatomy is desirable in TSA, there is lack of consensus regarding how much glenoid wear correction is acceptable and necessary in both anatomic and reverse TSA.¼ Use of augmented glenoid components is a relatively new treatment strategy for addressing moderate-to-severe glenoid wear in TSA. Augmented glenoid components allow for predictable and easy correction of glenoid wear in the coronal and/or axial planes while at the same time maximizing implant seating, improving rotator cuff biomechanics, and preserving glenoid bone stock because of off-axis glenoid reaming.¼ Augmented glenoid components have distinct advantages over glenoid bone grafting. Glenoid bone grafting is technically demanding, adds to the surgical time, and carries a risk of nonunion and graft resorption with subsequent failure of the glenoid component.¼ The use of augmented glenoid components in TSA is steadily increasing with easy availability of computed tomography-based preoperative planning software and guidance technology (patient-specific instrumentation and computer navigation).¼ Although different augment designs (full wedge, half wedge, and step cut) are available and a particular design may provide advantages in specific glenoid wear patterns to minimize bone removal (i.e. a half wedge in B2 glenoids), there is no evidence to demonstrate the superiority of 1 design over others.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Resorción Ósea , Cavidad Glenoidea , Escápula , Articulación del Hombro , Humanos , Artroplastia de Reemplazo/efectos adversos , Artroplastia de Reemplazo/métodos , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/métodos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Escápula/cirugía , Articulación del Hombro/cirugía , Resorción Ósea/etiología , Resorción Ósea/terapia
20.
JBJS Case Connect ; 13(4)2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37976377

RESUMEN

CASE: A 40-year-old man with shoulder pain secondary to severe bilateral glenoid hypoplasia without posterior instability was treated successfully with bilateral posterior glenoid bone graft augmentation. CONCLUSION: While glenoid hypoplasia is associated with a variety of patient presentations, treatment of the stable and nonarthritic shoulder is rarely described. A posterior glenoid bone graft can be used to augment deficient posterior glenoids, increasing the articulating surface area, restoring function, and potentially facilitating future shoulder arthroplasty.


Asunto(s)
Cavidad Glenoidea , Articulación del Hombro , Masculino , Humanos , Adulto , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Cavidad Glenoidea/cirugía , Hombro/cirugía , Escápula/cirugía , Artroplastia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...