1.
Am J Dent ; 37(2): 71-77, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704849

RESUMEN

PURPOSE: To investigate the effect of painless low-power Er:YAG laser irradiation of conventional and polymer-infiltrated ceramic network (PICN) type CAD-CAM resin-based composites (RBCs) on resin bonding. METHODS: An Er:YAG laser system, phosphoric acid etchant, universal adhesive, RBC, and two types of CAD-CAM RBC block were used. Microtensile bond strength, fracture mode, scanning electron microscopy (SEM) observations of bonding interfaces and CAD-CAM surfaces, and surface roughness of ground and pretreated surfaces were investigated. As pretreatment methods, low-power Er:YAG laser irradiation and air-abrasion with alumina particles were used. RESULTS: The effect of low-power Er:YAG laser irradiation of CAD-CAM RBCs on bonding to repair resin varied depending on the type of CAD-CAM RBCs. CLINICAL SIGNIFICANCE: The low-power Er:YAG laser irradiation of the conventional CAD-CAM RBCs was shown to be effective as a surface pretreatment for resin bonding, while the laser irradiation of PICN-type CAD-CAM RBCs was not effective.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Recubrimiento Dental Adhesivo , Láseres de Estado Sólido , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Resinas Compuestas/química , Resistencia a la Tracción , Ensayo de Materiales , Humanos , Cerámica/química , Grabado Ácido Dental
2.
J Biomed Mater Res B Appl Biomater ; 112(5): e35416, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38747324

RESUMEN

The bone formation response of ceramic bone graft materials can be improved by modifying the material's surface and composition. A unique dual-phase ceramic bone graft material with a nanocrystalline, hydroxycarbanoapatite (HCA) surface and a calcium carbonate core (TrelCor®-Biogennix, Irvine, CA) was characterized through a variety of analytical methods. Scanning electron microscopy (SEM) of the TrelCor surface (magnification 100-100,000X) clearly demonstrated a nanosized crystalline structure covering the entire surface. The surface morphology showed a hierarchical structure that included micron-sized spherulites fully covered by plate-like nanocrystals (<60 nm in thickness). Chemical and physical characterization of the material using X-ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR), and Scanning Electron Microscopy Energy Dispersive X-ray Spectroscopy (SEM-EDX) showed a surface composed of HCA. Analysis of fractured samples confirmed the dual-phase composition with the presence of a calcium carbonate core and HCA surface. An in vitro bioactivity study was conducted to evaluate whether TrelCor would form a bioactive layer when immersed in simulated body fluid. This response was compared to a known bioactive material (45S5 bioactive glass - Bioglass). Following 14-days of immersion, surface and cross-sectional analysis via SEM-EDX showed that the TrelCor material elicited a bioactive response with the formation of a bioactive layer that was qualitatively thicker than the layer that formed on Bioglass. An in vivo sheep muscle pouch model was also conducted to evaluate the ability of the material to stimulate an ectopic, cellular bone formation response. Results were compared against Bioglass and a first-generation calcium phosphate ceramic that lacked a nanocrystalline surface. Histology and histomorphometric analysis (HMA) confirmed that the TrelCor nanocrystalline HCA surface stimulated a bone formation response in muscle (avg. 11% bone area) that was significantly greater than Bioglass (3%) and the smooth surface calcium phosphate ceramic (0%).


Asunto(s)
Sustitutos de Huesos , Nanopartículas , Animales , Sustitutos de Huesos/química , Nanopartículas/química , Cerámica/química , Ensayo de Materiales , Durapatita/química , Ovinos , Microscopía Electrónica de Rastreo , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Difracción de Rayos X , Trasplante Óseo
3.
Int J Esthet Dent ; 19(2): 186-194, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726859

RESUMEN

OBJECTIVE: A diagnostic mock-up is a key tool that allows a preview of the outcome of an esthetic restoration. With recent developments in CAD/CAM technology, it is important to understand the pros and cons of chairside digital dentistry and the restorative materials used. The aim of the present case report is to describe in detail the use of a 3D-printed mock-up fabricated from a polymer-based material for an esthetic treatment plan within a fully digital workflow. CASE REPORT: A 45-year-old female patient presented at the clinic concerned about her esthetic appearance and the color of her anterior incisors. After a conclusive diagnosis, a restoration was planned using ceramic veneers from maxillary premolar to premolar. For a preview visualization of the outcome, an intraoral scanner was used to obtain 3D images and to allow the design of a digital smile. The template STL file was exported to a 3D printer and a 0.6-mm mock-up in A3-shade 3D resin was produced after 25 min. The mock-up was tested through a try-in and approved by the patient. As a result, the printed mock-up was considered predictable and reliable for the final restoration. CONCLUSIONS: The ease, speed, and reduced costs derived from the digital workflow, in conjunction with the accuracy of the mock-up, made the procedure highly efficient and recommendable.


Asunto(s)
Diseño Asistido por Computadora , Estética Dental , Impresión Tridimensional , Humanos , Femenino , Persona de Mediana Edad , Coronas con Frente Estético , Diseño de Prótesis Dental/métodos , Cerámica , Incisivo/diagnóstico por imagen
4.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702708

RESUMEN

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Fracaso de la Restauración Dental , Estética Dental , Técnica de Perno Muñón , Humanos , Cerámica , Análisis del Estrés Dental , Benzofenonas , Incisivo/lesiones , Materiales Dentales/química , Polietilenglicoles , Cetonas/química , Polímeros , Vidrio , Ensayo de Materiales , Diseño de Prótesis Dental
5.
J Appl Biomater Funct Mater ; 22: 22808000241250118, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38706266

RESUMEN

Despite the development of implant-supported prostheses, there are still patients for whom conservative treatments such as resin-bonded fixed dental prostheses (RBFDPs) are more appropriate. This study's objective was to analyze the available research on full-ceramic RBFDPs. In this study, Web of Science, MEDLINE/PubMed, Scopus, Embase, Cochrane Library, and Google Scholar databases were searched for articles published in English between 2010 and 2020. A total of 14 studies were reviewed based on the eligibility criteria. The results showed that using a cantilever design with one abutment had an advantage over two abutments. Additionally, it was proposed that preparations designed with retentive aids, such as a proximal box, groove, and pinhole, could improve RBFDP survival rates. IPS e.max ZirCAD, In-Ceram alumina, and zirconia CAD/CAM were the most commonly used framework materials. Most studies used air abrasion, salinization, or hydrofluoric acid for surface treatment. Adhesive resin cements were the most frequently used type of cement. The survival rate of In-Ceram ceramics (85.3%-94.8%) was lower than that of In-Ceram zirconia and IPS e.max ZirCAD. Debonding, followed by framework fracture, was the leading cause of failure. Following 3-10 years follow-up, the survival percentage of all-ceramic RBFDPs ranged from 76% to 100%. Although RBFDPs have demonstrated satisfactory success as a conservative treatment, long-term follow-ups and higher sample sizes in clinical research are required to gain more reliable outcomes on the clinical success rate of various RBFDP designs.


Asunto(s)
Cerámica , Humanos , Cerámica/química , Cementos de Resina/química , Porcelana Dental/química , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija con Resina Consolidada , Circonio/química
6.
BMC Oral Health ; 24(1): 513, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698366

RESUMEN

BACKGROUND: This study aims to evaluate the effect of surface treatment and resin cement on the shear bond strength (SBS) and mode of failure of polyetheretherketone (PEEK) to lithium disilicate ceramic (LDC). This is suggested to study alternative veneering of PEEK frameworks with a ceramic material. METHODS: eighty discs were prepared from PEEK blank and from lithium disilicate ceramic. Samples were divided into four groups according to surface treatment: Group (A) air abraded with 110 µm Al2O3, Group (AP) air abrasion and primer application, Group (S) 98% sulfuric acid etching for 60 s, Group (SP) Sulfuric acid and primer. Each group was subdivided into two subgroups based on resin cement type used for bonding LDC:1) subgroup (L) self- adhesive resin cement and 2) subgroup (B) conventional resin cement (n = 10). Thermocycling was done for all samples. The bond strength was assessed using the shear bond strength test (SBS). Failure mode analysis was done at 50X magnification with a stereomicroscope. Samples were chosen from each group for scanning electron microscope (SEM). The three-way nested ANOVA followed by Tukey's post hoc test were used for statistical analysis of results. Comparisons of effects were done utilizing one way ANOVA and (p < 0.05). RESULTS: The highest mean of shear bond strength values was demonstrated in Group of air abrasion with primer application using conventional resin cement (APB) (12.21 ± 2.14 MPa). Sulfuric acid groups showed lower shear bond strength values and the majority failed in thermocycling especially when no primer was applied. The failure mode analysis showed that the predominant failure type was adhesive failure between cement and PEEK, while the remaining was mixed failure between cement and PEEK. CONCLUSION: The air abrasion followed by primer application and conventional resin cement used for bonding Lithium Disilicate to PEEK achieved the best bond strength. Primer application did not have an effect when self-adhesive resin cement was used in air-abraded groups. Priming step is mandatory whenever sulfuric acid etching surface treatment is utilized for PEEK.


Asunto(s)
Benzofenonas , Recubrimiento Dental Adhesivo , Porcelana Dental , Análisis del Estrés Dental , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental/métodos , Ácidos Sulfúricos , Cerámica/química , Abrasión Dental por Aire/métodos , Óxido de Aluminio , Coronas con Frente Estético , Grabado Dental/métodos , Humanos
7.
Clin Oral Investig ; 28(5): 298, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702521

RESUMEN

OBJECTIVES: To assess the long-term clinical performance of ceramic in-/onlays (CIOs) and cast gold partial crowns (CGPCs) in posterior teeth in terms of success, survival, complications (biological, technical) and quality. MATERIAL AND METHODS: In a retrospective study, a total of 325 patients were recorded after up to 24.8 years (mean 13.9 ± 3.8 years) having (pre-)molars restored with CIO (Empress I, Ivoclar Vivadent, n = 161) and CGPC (Degunorm, DeguDent, n = 164) by supervised undergraduate students. A total of 296 restorations were assessed clinically and radiologically in healthy and endodontically treated teeth using modified United States Public Health Service (USPHS) criteria. Cumulative success and survival rates of the restorations were calculated using Kaplan-Meier estimates. Biological and technical complications were recorded. Status of oral health comprising caries risk and localized periodontitis were assessed. RESULTS: The cumulative success rates of CIOs were 92.1% and of CGPCs 84.2% after mean service times of 14.5 years. The annual failure rates of total service times were 0.5% in teeth restored with CIO (n = 155) and 0.7% in teeth restored with CGPC (n = 163). The cumulative survival rates of CIOs were 93.9% after a mean service time of 15.2 years and decreased to 91.7% after 23.5 years. The cumulative survival rates of CGPCs were 92.6% after a mean service time of 14.9 years and 91.8% after 23.5 years. Complications in CIOs (n = 149) were ceramic fracture (6.7%), secondary caries (4.7%), endodontic complication (2.7%) and tooth fracture (1.3%) compared to CGPCs (n = 147) with endodontic complication (8.8%), secondary caries (4.8%) and decementation (2.0%). Endodontically treated teeth restored with CIO or CGPC revealed significantly less often success compared with corresponding vital teeth (p = .02). CIOs and CGPCs revealed clinically and radiographically good and excellent qualities with 71.8% (107/149) and 68% (100/147) without any significant differences regarding type of restoration. CONCLUSIONS: Both CIOs and CGPCs achieved high survival rates up to 24.8 years when performed by supervised undergraduate students. The longevity of the restorations may benefit from the intraoral repair of accessible defects and, in case of pulp infection or necrosis, an adequate endodontic management. CLINICAL RELEVANCE: CIOs and CGPCs made by supervised undergraduate students are proper restoration types in posterior teeth in the long-term. An adequate preparation design, meticulous care in the inserting technique and constant biofilm removal due to proper oral hygiene combined with professional maintenance care are substantial. The clinical long-term performance was mostly limited by ceramic fractures in CIOs and endodontic complications in CGPCs.


Asunto(s)
Coronas , Fracaso de la Restauración Dental , Humanos , Estudios Retrospectivos , Femenino , Masculino , Adulto , Incrustaciones , Cerámica , Aleaciones de Oro , Caries Dental/terapia , Porcelana Dental/química , Persona de Mediana Edad , Diseño de Prótesis Dental , Diente no Vital , Resultado del Tratamiento
8.
J Contemp Dent Pract ; 25(3): 226-230, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38690694

RESUMEN

AIM: To assess the effectiveness of various surface treatments and adhesives on the bond strength of zirconia-based ceramic to dentin. MATERIALS AND METHODS: Eighty samples of zirconia were subjected to the four-surface treatment protocols (sandblasting, 48% hydrofluoric acid (HF), 48% hydrofluoric acid + 70% nitric acid (HNO3) and no treatment (control) following which the samples from each group were subdivided into two subgroups (n = 10) based on the resin cement employed for cementation (RelyX U200 and G-Cem Linkforce). The bonded specimens were subjected to shear stress to measure the bond strength using Universal testing machine. To test the difference in bond strength among the eight study groups, the Kruskal-Wallis ANOVA test was applied and for comparison between cements in each group, Mann-Whitney U test was applied. RESULTS: The highest bond strength values were observed for 48% HF group cemented with G-Cem Linkforce resin cement (16.220 ± 1.574) and lowest for control group-RelyX (4.954 ± 0.972). G-Cem cement showed higher bond strength than RelyX for all surface treatments except 48% HF + 70% nitric acid. CONCLUSION: It can be inferred that 48% HF can etch zirconia and generate a porous structure that proves to be beneficial for bonding. CLINICAL SIGNIFICANCE: The increasing demand for esthetics has led to the replacement of metal-ceramic materials with zirconia-based ceramics. However, the chemical inertness of zirconia to various conventional surface treating agents has continuously challenged researchers to discover a new surface treatment protocol that could enhance the bond strength of zirconia. How to cite this article: Yenamandra MS, Joseph A, Singh P, et al. Effect of Various Surface Treatments of Zirconia on its Adhesive Properties to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):226-230.


Asunto(s)
Recubrimiento Dental Adhesivo , Dentina , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Circonio , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Técnicas In Vitro , Humanos , Análisis del Estrés Dental , Resistencia al Corte , Ácido Fluorhídrico/química , Ácido Nítrico/química , Cerámica/química
9.
Water Environ Res ; 96(5): e11032, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38698675

RESUMEN

In recent years, ceramic membranes have been increasingly used in membrane bioreactors (MBRs). However, membrane fouling was still the core issue restricting the large-scale engineering application of ceramic MBRs. As a novel and alternative technology, ultrasonic could be used to control membrane fouling. This research focused on the efficiency and mechanism of ultrasonic controlling membrane fouling in ceramic MBRs. The results showed that ultrasonic reduced the sludge concentration in MBR, and the average particle size of sludge was always in a high range. The sludge activity of the system was stable at 6-9 (mg O2·(g MLSS·h)-1), indicating that ultrasonic did not destroy the activity of microorganisms in the system. The extracellular polymer substance (EPS) of the ultrasonic group was slightly higher than that of the control group, while the soluble microbial product (SMP) content was relatively stable. The ceramic membrane of the ultrasonic group has a partial retention effect on the organic components. The application of ultrasonic slowed down the decrease of the hydrophilicity of the ceramic membrane. The main pollutants on the membrane surface exist in the form of aromatic and heteroaromatic rings, alkynes, and so forth. Ultrasonic removes the amide substances from the membrane surface. Membrane fouling resistance is mainly due to membrane pore blockage, accounting for 75.53%. PRACTITIONER POINTS: Enrich the research on the mechanism of ultrasonic technology in membrane fouling control. The MBR can still operate normally with ultrasonic applied. The time for the ceramic membrane to reach the fouling end point is 2.4 times that without ultrasonic. The main cause of membrane fouling was pore blocking, accounting for 75.53%.


Asunto(s)
Reactores Biológicos , Cerámica , Membranas Artificiales , Cerámica/química , Eliminación de Residuos Líquidos/métodos , Aguas del Alcantarillado/química , Incrustaciones Biológicas/prevención & control
10.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124289, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38692101

RESUMEN

Biphasic calcium phosphate (BCP), consisting of bioceramics such as HAp + ß-TCP and Ca10(PO4)6(OH)2 + Ca3(PO4)2, is a popular choice for optimizing performance due to its superior biological reabsorption and osseointegration. In this study, BCP was produced by calcining the bones of tilapia fish (Oreochromis niloticus) reared in net cages and slaughtered at an age ranging from 15 to 420 days. The bones were cleaned and dried, calcined at 900 °C for 8 h, and then subjected to high-energy grinding for 3 h to produce BCP powders. After the calcination process, the crystalline phase's hydroxyapatite (HAp) and/or beta-tricalcium phosphate (ß-TCP) were present in the composition of the bioceramic. The age-dependent variation in phase composition was confirmed by complementary vibrational spectroscopy techniques, revealing characteristic peaks and bands of the bioceramic. This variation was marked by an increase in HAp phase and a decrease in ß-TCP phase. Thermogravimetric Analysis (TGA) and Differential Thermal Analysis (DTA) from 25 to 1400 °C showed the characteristic mass losses of the material, with a greater loss observed for younger fish, indicating the complete removal of organic components at temperatures above 600 °C. Comparison of the results obtained by X-Ray Diffraction (XRD) and Rietveld refinement with Raman spectroscopy showed excellent agreement. These results showed that with temperature and environment control and adequate fish feeding, it is possible to achieve the desired amounts of each phase by choosing the ideal age of the fish. This bioceramic enables precise measurement of HAp and ß-TCP concentrations and Ca/P molar ratio, suitable for medical orthopedics and dentistry.


Asunto(s)
Huesos , Cerámica , Espectrometría Raman , Animales , Cerámica/química , Huesos/química , Tilapia/metabolismo , Difracción de Rayos X , Hidroxiapatitas/química , Espectroscopía Infrarroja por Transformada de Fourier , Fosfatos de Calcio/química , Termogravimetría
11.
ACS Biomater Sci Eng ; 10(5): 3316-3330, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38619014

RESUMEN

In this study, we propose a spatially patterned 3D-printed nanohydroxyapatite (nHA)/beta-tricalcium phosphate (ß-TCP)/collagen composite scaffold incorporating human dental pulp-derived mesenchymal stem cells (hDP-MSCs) for bone regeneration in critical-sized defects. We investigated angiogenesis and osteogenesis in a rabbit critical-sized mandibular defect model treated with this engineered construct. The critical and synergistic role of collagen coating and incorporation of stem cells in the regeneration process was confirmed by including a cell-free uncoated 3D-printed nHA/ß-TCP scaffold, a stem cell-loaded 3D-printed nHA/ß-TCP scaffold, and a cell-free collagen-coated 3D-printed nHA/ß-TCP scaffold in the experimental design, in addition to an empty defect. Posteuthanasia evaluations through X-ray analysis, histological assessments, immunohistochemistry staining, histomorphometry, and reverse transcription-polymerase chain reaction (RT-PCR) suggest the formation of substantial woven and lamellar bone in the cell-loaded collagen-coated 3D-printed nHA/ß-TCP scaffolds. Histomorphometric analysis demonstrated a significant increase in osteoblasts, osteocytes, osteoclasts, bone area, and vascularization compared to that observed in the control group. Conversely, a significant decrease in fibroblasts/fibrocytes and connective tissue was observed in this group compared to that in the control group. RT-PCR indicated a significant upregulation in the expression of osteogenesis-related genes, including BMP2, ALPL, SOX9, Runx2, and SPP1. The findings suggest that the hDP-MSC-loaded 3D-printed nHA/ß-TCP/collagen composite scaffold is promising for bone regeneration in critical-sized defects.


Asunto(s)
Regeneración Ósea , Fosfatos de Calcio , Cerámica , Hidrogeles , Mandíbula , Neovascularización Fisiológica , Impresión Tridimensional , Andamios del Tejido , Animales , Conejos , Regeneración Ósea/efectos de los fármacos , Andamios del Tejido/química , Humanos , Cerámica/química , Fosfatos de Calcio/química , Hidrogeles/química , Osteogénesis/efectos de los fármacos , Células Madre Mesenquimatosas/metabolismo , Colágeno/química , Durapatita/química , Ingeniería de Tejidos/métodos , Pulpa Dental/citología , Modelos Animales de Enfermedad , Masculino , Angiogénesis
12.
J Dent ; 144: 104987, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38580056

RESUMEN

OBJECTIVES: To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS: A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS: Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS: Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE: Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Porcelana Dental , Diseño de Prótesis Dental , Ensayo de Materiales , Porcelana Dental/química , Humanos , Pilares Dentales , Cerámica/química , Propiedades de Superficie , Materiales Dentales/química , Adaptación Marginal Dental , Aleaciones de Cromo/química
13.
BMC Oral Health ; 24(1): 472, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38641578

RESUMEN

PURPOSE: The aim of the current study was to evaluate the effect of simulated gastric acid on the color and translucency of different indirect restorative materials. MATERIALS AND METHODS: A total of 36 disc-shaped samples were cut by using an isomet saw and divided into four equal groups (n = 9) according to the material type: Group Z: translucent zirconia (Ceramill® Zolid ht.+ preshade, Amann Girrbach, Koblach, Austria); Group E: lithium disilicate (IPS e.max CAD, Ivoclar Vivadent AG, Schaan, Liechtenstein); Group C: resin nanoceramic (Cerasmart, GC, Tokyo, Japan); Group P: polyether ether ketone (PEEK) (Bettin Zirconia Dentale Italy) veneered with indirect high impact polymer composite (HIPC) (breCAM HIPC, Bredent GmbH & Co. KG, Germany). The samples were immersed in simulated gastric acid (HCl, pH 1.2) for 96 hours at 37 °C in an incubator. The color change (ΔE00) and translucency (RTP00) were measured every 9.6 hours (one-year clinical simulation) of immersion in simulated gastric acid. RESULTS: For color change (∆E00) and translucency (RTP00) among the tested materials, there was a highly statistically significant difference (P < 0.001) after every year of follow-up. The color change in both Z and G groups was the lowest after 1 year of acid immersion, followed by that in group H, and the highest change in color was recorded in group P. CONCLUSION: High translucent zirconia is recommended in patients who are concerned about esthetic, especially with acidic oral environment.


Asunto(s)
Cerámica , Materiales Dentales , Humanos , Ensayo de Materiales , Circonio , Propiedades de Superficie , Color , Diseño Asistido por Computadora
14.
Dent Med Probl ; 61(2): 293-300, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38686971

RESUMEN

The systematic review aimed to compare and evaluate the effect of resin-based sealers and bioceramic sealers on postoperative pain after endodontic treatment. Two reviewers independently conducted electronic search in PubMed, the Web of Science, ScienceDirect, the Wiley Online Library, SpringerLink, Google Scholar, and the Cochrane Library, employing a complete dual-review process to ensure the inclusion of all relevant studies in the review. The search was carried out until November 2021. After selecting eligible studies, the risk of bias assessment was carried out using the revised Cochrane risk-ofbias tool for randomized trials (RoB 2). A total of 1,931 studies were identified from the electronic search, and finally 10 studies were included after full-text assessment. In all our included studies, the visual analog scale (VAS) was used for recording pain scores. Most of the studies recorded pain intensity starting from 6 h to 7 days. The results showed that there was no significant difference between resin-based sealers and bioceramic sealers in terms of incidence or intensity of postoperative pain at any point in time.


Asunto(s)
Dolor Postoperatorio , Materiales de Obturación del Conducto Radicular , Humanos , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/prevención & control , Materiales de Obturación del Conducto Radicular/efectos adversos , Cerámica , Tratamiento del Conducto Radicular/efectos adversos , Dimensión del Dolor
16.
J Chromatogr A ; 1725: 464897, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38678694

RESUMEN

Reliable modeling of oily wastewater emphasizes the paramount importance of sustainable and health-conscious wastewater management practices, which directly aligns with the Sustainable Development Goals (SDG) while also meeting the guidelines of the World Health Organization (WHO). This research explores the efficiency of utilizing polypyrrole-coated ceramic-polymeric membranes to model oily wastewater separation efficiency (SE) and permeate flux (PF) based on established experimental procedures. In this area, computational simulation still needs to be explored. The study developed predictive regression models, including robust linear regression (RLR), stepwise linear regression (SWR) and linear regression (LR) for the ceramic-polymeric porous membrane, aiming to interpret its complex performance across diverse conditions and, thus, develop its utility in oily wastewater treatment applications. Subsequently, a novel, simple average ensemble paradigm was explored to reduce errors and improve prediction skills. Prior to the development of the model, stability and reliability analysis of the data was conducted based on Philip Perron tests with the Bartlett kernel estimation method. The accuracy of the SE exhibited a high consistency, averaging 99.92% with minimal variability (standard deviation of 0.026%), potentially simplifying its prediction compared to PF. The modes were validated and evaluated using metrics like MAE, RMSE, Speed, and MSE, in addition to 2D graphical and cumulative distribution function graphs. The LR model emerged as the best with the lowest RMSE =0.21951, indicating superior prediction accuracy, followed closely by RLR with an RMSE = 0.22359. SWLR, while having the highest RMSE = 0.34573, marked its dominance in prediction speed with 110 observations per second. Notably, the RLR model justified a reduction in error by approximately 35.29% compared to SWLR. Moreover, the training efficiency of the LR model exceeded, demanding a mere 2.9252 s, marking a reduction of about 32.54% compared to SWLR. The improved simple ensemble learning proved merit over the three models regarding error accuracy. This study emphasizes the essential role of soft-computing learning in optimizing the design and performance of ceramic-polymeric membranes.


Asunto(s)
Cerámica , Membranas Artificiales , Polímeros , Pirroles , Aguas Residuales , Polímeros/química , Aguas Residuales/química , Pirroles/química , Cerámica/química , Modelos Lineales , Purificación del Agua/métodos , Porosidad , Reproducibilidad de los Resultados , Simulación por Computador
17.
Eur J Oral Sci ; 132(3): e12989, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38679835

RESUMEN

This study aimed at examining the bond strength between zirconia and ceramic veneer, following the ISO 9693 guidelines. A total of fifty specimens of zirconia/ceramic-veneer system were produced using two commercial zirconias (VITA YZ-HTWhite and Zolid HT+ White, referred to as Group A and Group B, respectively) and a ceramic-veneering material (Zirkonia 750). The microstructure (via x-ray diffraction analysis, XRD and Secondary Electron mode, SEM) and the mechanical properties (via 3-point bending tests) of the two groups were assessed. Then, experiments were conducted according to the ISO 9693 and conventional protocols applied for producing zirconia/ceramic-veneer restorations. Bond strength values, measured by 3-point bending tests, were 34.42 ± 7.60 MPa for Group A and 31.92 ± 6.95 MPa for Group B. SEM observations of the cohesively fractured surfaces (on the porcelain side) and the examination for normality using the Shapiro-Wilk test suggested the use of Weibull statistical analysis. Median strength (σ50%) for Group A and Group B was 34.76 and 32.22 MPa, while the characteristic strength (σ63.2%) was 35.78 and 33.14 MPa, respectively. The Weibull modulus disparity between groups (12.69 and 13.07) was not significant. Bond strength exceeded the ISO 9693 minimum of 20 MPa, suggesting satisfactory strength for clinical use.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Análisis del Estrés Dental , Coronas con Frente Estético , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Difracción de Rayos X , Circonio , Circonio/química , Porcelana Dental/química , Propiedades de Superficie , Cerámica/química , Materiales Dentales/química , Humanos
18.
Biomed Res Int ; 2024: 6670159, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38606199

RESUMEN

Objective: This research study investigated the effect of new decontamination protocols on the bonding capacity of saliva-contaminated monolithic zirconia (MZ) ceramics cemented with two different monomer-containing self-adhesive resin cements. Materials and Methods: Standardized tooth preparations (4 mm. axial height) were performed for eighty human maxillary premolars under constant water cooling system. Eighty monolithic zirconia crowns (Whitepeaks Supreme Monolith) (n = 8/10 groups) were manufactured by CAD-CAM. Specimens were kept in the artificial saliva at pH = 7.3 for 1 minute at 37°C except control groups. The specimens have not been prealumina blasted and grouped according to cleaning methods and resin cements: control groups (C) (no saliva contamination + GPDM + 4-META (N) (CN) and 10-MDP (M) containing resin cement (CM), alumina blasted (AL) + GPDM + 4-META (ALN) and 10-MDP containing resin cement (ALM), zirconium oxide containing universal cleaning agent (IC) applied + GPDM + 4-META (N) (ICN) and 10-MDP containing resin cement (ICM), pumice (P) applied + GPDM + 4-META (PN) and 10-MDP containing resin cement (PM), and air-water spray (AW) applied + GPDM + 4-META (AWN) and 10-MDP containing resin cement (AWM)). Monobond Plus was applied to all surfaces for 40 seconds before cementation. The thermal cycle was applied at 5,000 cycles after cementation. The crowns were tested in tensile mode at a speed of 1 mm/min. The mode of failure was recorded. SEM examinations were carried out at different magnifications. Data were analyzed using rank-based Kruskal-Wallis and Mann-Whitney tests. Results: No significant differences were found between the surface treatments and between the two types of resin cements. Interaction effects between surface treatments and resin cements were found to be significant by two-way ANOVA analysis. ICM group resulted in significantly better bond strength results compared with CN. ICM was found to result in better bond strength results compared with PM. The combination of universal cleaning agent and 10-MDP containing resin cement had significantly the highest cementation bond strength values. The increasing order of mean tensile bond strength values of decontamination protocols was C < AW < P < AL < IC. The mean tensile bond strength of 10-MDP containing resin cement was slightly higher than GPDM + 4-META containing resin cement. Conclusions: Universal cleaning agents can be preferred as an efficient cleaning method with 10-MDP-containing cement after saliva contamination for better adhesive bond strength of 4 mm crown preparation height of monolithic zirconia ceramics.


Asunto(s)
Recubrimiento Dental Adhesivo , Metacrilatos , Cementos de Resina , Humanos , Cementos de Resina/química , Saliva , Descontaminación , Ensayo de Materiales , Circonio/química , Cerámica/química , Agua/química , Resistencia al Corte , Propiedades de Superficie , Análisis del Estrés Dental
19.
Int J Mol Sci ; 25(7)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38612634

RESUMEN

The functionalization of bone substitutes with exosomes appears to be a promising technique to enhance bone tissue formation. This study investigates the potential of exosomes derived from bone marrow mesenchymal stromal cells (BMSCs) to improve bone healing and bone augmentation when incorporated into wide open-porous 3D-printed ceramic Gyroid scaffolds. We demonstrated the multipotent characteristics of BMSCs and characterized the extracted exosomes using nanoparticle tracking analysis and proteomic profiling. Through cell culture experimentation, we demonstrated that BMSC-derived exosomes possess the ability to attract cells and significantly facilitate their differentiation into the osteogenic lineage. Furthermore, we observed that scaffold architecture influences exosome release kinetics, with Gyroid scaffolds exhibiting slower release rates compared to Lattice scaffolds. Nevertheless, in vivo implantation did not show increased bone ingrowth in scaffolds loaded with exosomes, suggesting that the scaffold microarchitecture and material were already optimized for osteoconduction and bone augmentation. These findings highlight the lack of understanding about the optimal delivery of exosomes for osteoconduction and bone augmentation by advanced ceramic scaffolds.


Asunto(s)
Exosomas , Células Madre Mesenquimatosas , Médula Ósea , Proteómica , Ingeniería de Tejidos , Huesos , Cerámica
20.
Int J Mol Sci ; 25(7)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38612749

RESUMEN

A large amount of primary energy is lost due to friction, and the study of new additive materials to improve friction performance is in line with the concept of low carbon. Carbon nanotubes (CNTs) have advantages in drag reduction and wear resistance with their hollow structure and self-lubricating properties. This review investigated the mechanism of improving friction properties of blocky composites (including polymer, metal, and ceramic-based composites) with CNTs' incorporation. The characteristic tubular structure and the carbon film make low wear rate and friction coefficient on the surface. In addition, the effect of CNTs' aggregation and interfacial bond strength on the wear resistance was analyzed. Within an appropriate concentration range of CNTs, the blocky composites exhibit better wear resistance properties. Based on the differences in drag reduction and wear resistance in different materials and preparation methods, further research directions of CNTs have been suggested.


Asunto(s)
Nanotubos de Carbono , Cerámica , Fricción , Polímeros , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...