Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 415
Filtrar
1.
Am J Dent ; 37(5): 263-267, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39321107

RESUMEN

PURPOSE: To evaluate the marginal and internal misfit of fixed partial denture zirconia frameworks developed from conventional impression and intraoral scanning, before and after being subjected to the thermal cycle of the covering ceramic. METHODS: A three-elements fixed partial denture was prepared, molded, and poured with polyurethane. Group CI (n= 7) was impressed by the conventional technique with polyvinyl siloxane material, and the plaster models scanned on the inEosX5 bench scanner. Group DI (n=07) was scanned using the CEREC Bluecam intraoral scanner. The models and images obtained were sent to the laboratory and the frameworks were made using zirconia blocks. After this, they were subjected to the ceramic thermal cycle, simulating the ceramic application. Marginal and internal misfits of the frameworks were measured before (T1) and after (T2) thermal cycle simulation using the replica technique in an optical microscope. Statistical analysis was performed using the mixed effects of linear model tests and comparisons. RESULTS: There were no statistical differences for axial misfit. Significant differences were found between the groups for occlusal, vertical, horizontal, and absolute misfit, where group CI had higher values than group DI (P< 0.001). At the time, there was a statistical difference only in the absolute misfit, where T1 had lower values than T2. The misfit in group CI was greater than in group DI; however, the average misfit values found are low and considered clinically acceptable. CLINICAL SIGNIFICANCE: Knowing marginal and internal misfit is an important step to consolidating digital impressions in fixed partial dentures, implying a secure use of this technique.


Asunto(s)
Diseño Asistido por Computadora , Técnica de Impresión Dental , Adaptación Marginal Dental , Diseño de Dentadura , Dentadura Parcial Fija , Circonio , Circonio/química , Diseño de Dentadura/métodos , Humanos , Siloxanos/química , Materiales de Impresión Dental/química , Polivinilos/química , Modelos Dentales
2.
Braz Dent J ; 35: e245917, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39320003

RESUMEN

To evaluate the fracture load of bilayer ceramic crowns manufactured by Rapid Layer Technology (RLT) after different cementation protocols of the veneering ceramic to the zirconia infrastructures. Sixty epoxy resin preparations simulating a molar tooth were obtained and 60 zirconia infrastructures and feldspathic crowns were manufactured by RLT and divided into 6 groups according to the cementation protocol at the interface to veneering ceramic (n=10): Ctr- control: conventional resin cement; Al- Al2O3 sandblasting 50µm + conventional resin cement; Al/MDP- Al2O3 sandblasting (50µm) + resin cement with MDP; Sil- silicatization 30µm + conventional resin cement; Gl/HF- glaze + hydrofluoridric acid (5%,60s) + silane + conventional resin cement; Gl- glazing as bonding agent. The feldspathic ceramic internal surface was etched with fluoridric acid (5%) + silane followed by cementation according to respective protocols. All samples were mechanically cycled (200N and 4.5x105 Pa, 37°C, 2x106 cycles, 3.4Hz) and submitted to axial compressing fracture load test (10kN, 0.5mm/min). The results(N) were submitted to descriptive and analytical statistical analysis with 1-way ANOVA, Weibull, and the Tukey test (α=0.05). ANOVA revealed that there was a significant difference among the tested groups (p<0.0001). The group Al/MDP presented the higher resistance to fracture (1972.46A N), followed by the Ctr group (1584.41B N). The characteristic strength(σ0) was significantly different (p=0.000). The crack and chipping were the predominant failures. The air-abrasion at the external surface of zirconia with Al2O3 followed by cementation with MDP resin cement, should be selected to Rapid Layer Technique when felspathic ceramic is used as veneer ceramic.


Asunto(s)
Cementación , Cerámica , Coronas , Análisis del Estrés Dental , Ensayo de Materiales , Cerámica/química , Cementación/métodos , Circonio/química , Fracaso de la Restauración Dental , Cementos Dentales/química
3.
Braz Oral Res ; 38: e077, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39258630

RESUMEN

Borosilicate glass was developed to enhance the mechanical behavior and smoothness of dental zirconia as an alternative to conventional glaze. This study assessed the mechanical and optical properties of 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) coated with borosilicate glass or a commercial glaze fired for an extended period of time. Disc-shaped 3Y-TZP zirconia specimens (Zpex, Tosoh) were sintered at 1550°C for 2 hours. The specimens were divided into three groups: as-sintered (control, C); commercial glaze (G); and borosilicate glass (SL). The glaze and borosilicate glass were applied over the zirconia and fired for 20 minutes at 950°C and 1200°C, respectively. Biaxial flexural strength, fractography, X-ray diffraction (XRD), roughness (Ra and Rz), fracture toughness (Vickers indentation method), color difference (∆E00), and translucency (TP00) analyses were conducted. The t-test or the one-way ANOVA and Tukey's tests were used to analyze the data (α = 0.05). Flexural strength data were subjected to the Weibull analysis. The SL group exhibited the highest flexural strength (1025.8 MPa), whereas the C (859.41 MPa) and G (816.0 MPa) groups exhibited similar values. The SL group also had the highest characteristic strength. The fracture origin in all groups was on the zirconia surface. XRD analysis revealed that the specimens from the SL group contained tetragonal, cubic, and monoclinic phases. The SL group presented the lowest surface roughness. Fracture toughness in the SL group was lower than in the C group, but similar to that observed in the G group. The translucency and color differences observed in the G and SL groups were similar. Borosilicate glass enhanced the flexural strength of 3Y-TZP, promoted the smoothest surface, and exhibited optical properties similar to those of the glaze.


Asunto(s)
Vidrio , Ensayo de Materiales , Propiedades de Superficie , Difracción de Rayos X , Itrio , Circonio , Circonio/química , Itrio/química , Vidrio/química , Análisis de Varianza , Factores de Tiempo , Resistencia Flexional , Silicatos/química , Reproducibilidad de los Resultados , Valores de Referencia , Estadísticas no Paramétricas , Color , Fenómenos Ópticos , Pruebas de Dureza , Materiales Dentales/química
4.
Biomed Res Int ; 2024: 5394652, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39220997

RESUMEN

Background: Adhesion to zirconia remains a significant dental challenge. This study is aimed at assessing the bond strength of zirconia based on surface treatment with pre or postsintering sandblasting associated with different chemical treatments and resin cements. Methods: Zirconia blocks were divided into 12 experimental groups based on the surface treatment (presintering sandblasting or postsintering sandblasting/tribochemical abrasion treatment), chemical treatment (none, Single Bond Universal, or Signum Zirconia Bond), and choice of cement (Panavia F or RelyX™ U200). The bond strength was measured by shear tests using a universal testing machine. The fracture analysis was performed using stereomicroscopy. Data were analyzed using three-way ANOVA and Tukey's test (α = 5%). Results: Triple and double factor's interactions were not significant (p > 0.05). Regarding the surface treatment factor, the bond strength following postsintering sandblasting treatment associated with tribochemical abrasion (9.15 ± 3.62 MPa) was significantly higher than presintering sandblasting treatment (5.24 ± 3.53 MPa). Concerning the chemical treatment factor, bond strengths were ranked as follows: Signum Zirconia Bond > Single Bond Universal > no treatment. The bond strength of the resin cements did not differ among them. Most fractures (67%) were classified as adhesive, and 32% were categorized as mixed fractures. Conclusion: Surface treatment via postsintering sandblasting combined with tribochemical abrasion demonstrated superior efficacy than in presintering sandblasting. Additionally, chemical treatment with zirconia primer increased the bond strength of zirconia irrespective of the surface physical treatment.


Asunto(s)
Recubrimiento Dental Adhesivo , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Circonio , Circonio/química , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Resistencia al Corte , Cementos Dentales/química , Humanos
5.
Oper Dent ; 49(5): 574-585, 2024 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-39169511

RESUMEN

This laboratory study aimed to evaluate the effects of zirconium dioxide (ZrO2) slurry surface treatment on the bond strength of ultratranslucent zirconia to resin cement using different ceramic primers. The surface morphology was evaluated by scanning electron microscopy (SEM) and atomic force microscopy (AFM), and the interface was evaluated by SEM. Additionally, the phase composition was analyzed by X-ray diffraction (XRD). Specimens of zirconia (n=120) were obtained and divided into two groups according to the surface treatment: (1) airborne particle abrasion with 50-µm aluminum oxide (n=60) and (2) ZrO2 slurry (n=60). The 60 specimens were then further divided into three groups (n=20) according to the ceramic primer application: no primer (NP), Monobond N (MB), and Clearfil ceramic primer (CP). Four resin cement cylinders were built on each ceramic specimen. Half of the specimens (n=10) were subjected to a microshear bond strength (µSBS) test after 24 hours of storage in distilled water, and the other half (n=10) were subjected to a µSBS test after thermocycling. Additional specimens were prepared for SEM, AFM, and XRD analyses. According to the Kruskal-Wallis and Student-Newman-Keuls post hoc tests, the µSBS values were significantly higher for MB and CP than for NP (p<0.05), and there were no significant differences in µSBS for both surface treatments associated with MB and CP after 24 hours of storage (p>0.05). Thermocycling significantly decreased the µSBS values for all specimens, especially for the NP groups and ZrO2 slurry treatment groups, and gaps at the interface were observed by SEM. SEM and AFM analyses showed agglomerate-type irregularities on the ceramic surface for ZrO2 slurry treatment. XRD spectra showed that ZrO2 slurry did not cause phase transformation. It was concluded that ZrO2 slurry promoted irregularities on the ultratranslucent zirconia surface, not causing phase transformation; moreover, the values of µSBS were comparable to those of airborne particle abrasion with aluminum oxide. However, neither surface treatment nor ceramic primer prevented the degradation of the interface.


Asunto(s)
Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Microscopía Electrónica de Rastreo , Cementos de Resina , Propiedades de Superficie , Circonio , Circonio/química , Cementos de Resina/química , Cementos de Resina/uso terapéutico , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales , Microscopía de Fuerza Atómica , Difracción de Rayos X , Metacrilatos
6.
J Esthet Restor Dent ; 36(10): 1444-1451, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38963682

RESUMEN

OBJECTIVE: To evaluate the effect of the deterioration of computer aided design/computer aided manufacturing (CAD/CAM) burs during zirconia milling, on surface roughness, contact angle, and fibroblast viability. MATERIALS AND METHODS: Ceramic blocks were milled and 75 ceramic disks (8 × 1.5 mm) made and allocated into three groups (n = 25): G1-brand new 2L and 1L burs, G2-2L bur at the end of lifetime and brand new 1L bur and G3-both burs at the end of their lifetimes. Roughness (Ra, Rq, and Rz) was evaluated using a 3D optical profilometer, the contact angle by the sessile drop method and the cell viability of the mouse NIH/3T3 fibroblast, using the Alamar Blue assay at intervals of 24, 48, and 72 h (ISO 10993-5). Data were analyzed by one-way ANOVA and Kruskal-Wallis tests (p ≤ 0.05). RESULTS: Roughness increased as the burs deteriorated and G3 (0.27 ± 0.04) presented a higher value for Ra (p < 0.001). The highest contact angle was observed in G3 (86.2 ± 2.66) when compared with G1 (63.7 ± 12.49) and G2 (75.3 ± 6.36) (p < 0.001). Alamar Blue indicated an increase in cell proliferation, with no significant differences among the groups at 24 and 72 h (p > 0.05). CONCLUSIONS: The deterioration of the burs increased the surface roughness and decreased the wettability, but did not interfere in cell viability and proliferation. CLINICAL SIGNIFICANCE: The use of custom zirconia abutments represents an effective strategy for single crowns restorations. Our findings suggest that these abutments can be efficiently milled using CAD/CAM burs within their recommended lifetime.


Asunto(s)
Diseño Asistido por Computadora , Propiedades de Superficie , Circonio , Circonio/química , Ratones , Animales , Pilares Dentales , Materiales Biocompatibles , Células 3T3 NIH , Ensayo de Materiales
7.
J Dent ; 148: 105242, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-39009334

RESUMEN

OBJECTIVE: To investigate fatigue methods for the evaluation of translucent zirconia and to associate in vitro failures with clinically reported ones. DATA: Studies published in English that used fatigue tests on dental translucent zirconia. SOURCES: Two databases (MEDLINE/PubMed and Scopus) were electronically searched without any restriction on year of publication. STUDY SELECTION: A total of 4555 studies were identified. After removal of duplicates (78) and irrelevant articles (4316) that did not meet the inclusion criteria, 161 articles were considered eligible based on their titles and abstracts. These articles were fully read, leading to the inclusion of 41 studies in the review. RESULTS: The most widely used fatigue method for evaluation of translucent zirconia was step-stress (18 articles), followed by staircase (seven articles), and step-wise (two articles). Most studies had been conducted in a wet environment with the use of a stainless steel piston to apply load to cemented structures on a dentin-like substrate. Most fracture analyses indicated the fracture originated on the cementation or contact surface where the load was applied. Moreover, studies that utilized anatomical structures (dental crowns) reported fractures starting at the cervical margin of the crowns. CONCLUSION: Most studies used the step-stress method. Only three studies reported failures similar to those found in clinical trials that used translucent zirconia restorations. CLINICAL SIGNIFICANCE: The study findings can assist on correlating clinical failures to the ones observed in vitro.


Asunto(s)
Materiales Dentales , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Ensayo de Materiales , Circonio , Circonio/química , Humanos , Materiales Dentales/química , Coronas , Propiedades de Superficie , Estrés Mecánico
8.
Int J Mol Sci ; 25(13)2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-39000425

RESUMEN

This study investigated the impact of adding hydroxyapatite nanoparticles to implant surfaces treated with zirconia blasting and acid etching (ZiHa), focusing on structural changes and bone healing parameters in low-density bone sites. The topographical characterization of titanium discs with a ZiHa surface and a commercially modified zirconia-blasted and acid-etched surface (Zi) was performed using scanning electron microscopy, profilometry, and surface-free energy. For the in vivo assessment, 22 female rats were ovariectomized and kept for 90 days, after which one implant from each group was randomly placed in each tibial metaphysis of the animals. Histological and immunohistochemical analyses were performed at 14 and 28 days postoperatively (decalcified lab processing), reverse torque testing was performed at 28 days, and histometry from calcified lab processing was performed at 60 days The group ZiHa promoted changes in surface morphology, forming evenly distributed pores. For bone healing, ZiHa showed a greater reverse torque, newly formed bone area, and bone/implant contact values compared to group Zi (p < 0.05; t-test). Qualitative histological and immunohistochemical analyses showed higher features of bone maturation for ZiHa on days 14 and 28. This preclinical study demonstrated that adding hydroxyapatite to zirconia-blasted and acid-etched surfaces enhanced peri-implant bone healing in ovariectomized rats. These findings support the potential for improving osseointegration of dental implants, especially in patients with compromised bone metabolism.


Asunto(s)
Durapatita , Nanopartículas , Oseointegración , Propiedades de Superficie , Circonio , Circonio/química , Animales , Durapatita/química , Durapatita/farmacología , Femenino , Ratas , Nanopartículas/química , Oseointegración/efectos de los fármacos , Implantes Dentales , Titanio/química , Tibia/efectos de los fármacos , Tibia/cirugía , Grabado Ácido Dental
9.
Sci Rep ; 14(1): 13262, 2024 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858417

RESUMEN

The purpose of this study was to evaluate the fatigue survival of 5Y-PSZ zirconia infiltrated with an experimental glass and bonded onto dentin analogues. Disc-shaped specimens of a 5Y-PSZ (Katana UTML Kuraray Noritake) were cemented onto dentin analogs (NEMA G10) and divided into four groups (n = 15): Zctrl Group (control, without infiltration); Zglz Group (Glaze, compression surface); Zinf-comp Group (Experimental Glass, compression surface); Zinf-tens Group (Experimental Glass, tension surface). Surface treatments were varied. Cyclic fatigue loading, oblique transillumination, stereomicroscope examination, and scanning electron microscopy were performed. Fatigue data were analyzed (failure load and number of cycles) using survival analysis (Kaplan-Meier and Log-Rank Mantel-Cox). There was no statistically significant difference in fatigue survival between the Zglz, Zctrl, and Zinf-comp groups. The Zinf-tens group presented a significantly higher failure load when compared to the other groups and exhibited a different failure mode. The experimental glass effectively infiltrated the zirconia, enhancing structural reliability, altering the failure mode, and improving load-bearing capacity over more cycles, particularly in the group where the glass was infiltrated into the tensile surface of the zirconia. Glass infiltration into 5Y-PSZ zirconia significantly enhanced structural reliability and the ability to withstand loads over an increased number of cycles. This approach has the potential to increase the durability of zirconia restorations, reducing the need for replacements and save time and resources, promoting efficiency in clinical practice.


Asunto(s)
Dentina , Vidrio , Ensayo de Materiales , Circonio , Circonio/química , Vidrio/química , Dentina/química , Humanos , Microscopía Electrónica de Rastreo , Propiedades de Superficie
10.
Food Res Int ; 186: 114337, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38729718

RESUMEN

A major concern for wineries is haze formation in white wines due to protein instability. Despite its prevalent use, the conventional bentonite method has shortcomings, including potential alteration of color and aroma, slow processing times, and notable wine wastage. Zirconium oxide (ZrO2) effectively removes proteins without affecting wine characteristics. However, producing cost-effective ZrO2 materials with efficient protein removal capabilities poses a significant challenge. This research aims to assess the viability of designing a porous material impregnated with zirconia to remove turbidity-causing proteins effectively. For this purpose, the support material alone (Al2O3) and the zirconia-impregnated support (ZrO2/Al2O3) were subjected to different calcination temperatures. It was observed that high-temperature treatments (750 °C) enhanced wine stability and protein adsorption capacity. The optimal adsorbent achieved a notable reduction in turbidity, decreasing the ΔNTU from 42 to 18, alongside a significant 44 % reduction in the total protein content, particularly affecting proteins in the molecular weight range of 10 to 70 kDa. This result is attributed to modifying the textural properties of ZrO2/Al2O3, characterized by the reduction of acidic sites, augmented pore diameters from 4.81 to 7.74 nm, and the emergence of zirconia clusters across the surface of the porous support. In summary, this study presents the first application of zirconia on the alumina support surface for protein stabilization in white wine. Combining ZrO2/Al2O3 and a high-temperature treatment emerges as a promising, cost-efficient, and environmentally sustainable strategy for protein removal in white wine.


Asunto(s)
Óxido de Aluminio , Vino , Circonio , Vino/análisis , Circonio/química , Óxido de Aluminio/química , Adsorción , Estabilidad Proteica , Calor , Manipulación de Alimentos/métodos
11.
Clin Oral Investig ; 28(6): 336, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38795258

RESUMEN

OBJECTIVE: Stress distribution assessment by finite elements analysis in poly(etheretherketone) (PEEK) implant and abutment as retainers of single crowns in the anterior region. MATERIALS AND METHODS: Five 3D models were created, varying implant/abutment manufacturing materials: titanium (Ti), zirconia (Zr), pure PEEK (PEEKp), carbon fiber-reinforced PEEK (PEEKc), glass fiber-reinforced PEEK (PEEKg). A 50 N load was applied 30o off-axis at the incisal edge of the upper central incisor. The Von Mises stress (σvM) was evaluated on abutment, implant/screw, and minimum principal stress (σmin) and maximum shear stress (τmax) for cortical and cancellous bone. RESULTS: The abutment σvM lowest stress was observed in PEEKp group, being 70% lower than Ti and 74% than Zr. On the implant, PEEKp reduced 68% compared to Ti and a 71% to Zr. In the abutment screws, an increase of at least 33% was found in PEEKc compared to Ti, and of at least 81% to Zr. For cortical bone, the highest τmax values were in the PEEKp group, and a slight increase in stress was observed compared to all PEEK groups with Ti and Zr. For σmin, the highest stress was found in the PEEKc. Stress increased at least 7% in cancellous bone for all PEEK groups. CONCLUSION: Abutments and implants made by PEEKc concentrate less σvM stress, transmitting greater stress to the cortical and medullary bone. CLINICAL RELEVANCE: The best stress distribution in PEEKc components may contribute to decreased stress shielding; in vitro and in vivo research is recommended to investigate this.


Asunto(s)
Benzofenonas , Coronas , Pilares Dentales , Análisis del Estrés Dental , Análisis de Elementos Finitos , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Titanio , Circonio , Cetonas/química , Polietilenglicoles/química , Humanos , Circonio/química , Titanio/química , Fibra de Carbono/química , Diseño de Implante Dental-Pilar , Incisivo , Materiales Dentales/química , Implantes Dentales de Diente Único , Hueso Cortical , Vidrio/química , Diseño de Prótesis Dental
12.
Am J Dent ; 37(2): 101-105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704853

RESUMEN

PURPOSE: To evaluate the effect of toothbrushing with conventional and whitening dentifrices on the color difference (ΔE00), gloss (Δgloss), and surface roughness (SR) of stained stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) after polishing or glazing. METHODS: Specimens were divided into four groups (n=20): C (control), S (staining), SG (staining and glazing) and SP (staining and polishing). 50,000 toothbrushing cycles were performed with conventional (n=10) and whitening (n= 10) dentifrice slurries. The ΔE00 and Δgloss were measured using a spectrophotometer and CIEDE2000 system while SR was measured by laser confocal microscope. The ΔE00 and Δgloss data were analyzed using 2-way ANOVA, and SR data were analyzed using the linear repeated measures model, with Bonferroni's complementary test (α= 0.05). RESULTS: The ΔE00 values were beyond the acceptability threshold and no differences were found among the groups. There was no difference among groups to Δgloss after toothbrushing with conventional dentifrice while SP presented the highest values of Δgloss after toothbrushing with whitening dentifrice. Conventional dentifrice decreased the SR of stained groups and whitening dentifrice decreased SR of S and SG. The toothbrushing with conventional and whitening dentifrices promoted color difference, but did not impair gloss and surface roughness of stained 5Y-TZP. CLINICAL SIGNIFICANCE: Monolithic zirconia has been routinely used for esthetic restorations, however the type of finishing procedures that is carried out on it must be taken into consideration, in addition to the fact that brushing can influence the color difference of the material as well as interfere with surface roughness and gloss.


Asunto(s)
Dentífricos , Propiedades de Superficie , Cepillado Dental , Circonio , Circonio/química , Dentífricos/uso terapéutico , Color , Blanqueadores Dentales/uso terapéutico , Pulido Dental/métodos , Itrio/química , Humanos , Ensayo de Materiales , Blanqueamiento de Dientes/métodos , Espectrofotometría , Microscopía Confocal
13.
J Mech Behav Biomed Mater ; 156: 106569, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38776741

RESUMEN

This study aimed to produces and characterize bovine hydroxyapatite (HA) bioceramic with 3Y-TZP addition and analyze different sintering curves. HA was extracted from bovine bones and nanoparticulated. HA discs (0, 1, 5 and 10 wt% 3Y-TZP) were subjected to uniaxial and isostatic pressing. Dilatometry analysis was performed and the groups were sintered using 3 different firing curves (conventional, 1300 °C; 2-step, 1292 °C; 2-step, 1420 °C). The samples were analyzed by X-ray diffraction (XRD), biaxial flexural strength (BFS), Vickers microhardness (VH) and Field emission scanning electron microscopy (FE-SEM). The dilatometry results signaled the need for sintering optimization in groups added with 3Y-TZP. XRD demonstrated the characteristic crystallographic peaks of HA in the pure groups and with 1% 3Y-TZP, and decomposition of HA into ß-TCP and formation of calcium zirconate in the groups with 5 and 10% 3Y-TZP. Considering each composition, the groups of pure HA (131.3 ± 13.5 MPa; 401 ± 12.7 GPa) sintered by the conventional curve and HA+1%3Y-TZP (145 ± 8.6 MPa; 507 ± 47.9 GPa), HA+5%3Y-TZP (68.1 ± 14.2 MPa; 183 ± 9.8 GPa) and HA+10%3Y-TZP (55.6 ± 5.1 MPa; 96.1 ± 7.64 GPa) sintered by the 2-step curve at 1420 °C, combined the best BFS and VH results. The addition of 1 wt% 3Y-TZP and optimization in the sintering process improved the mechanical and microstructural properties of HA bioceramics and maintenance of its crystalline characteristics. Refinement in material processing is necessary for the future use of this bioceramic in dentistry.


Asunto(s)
Cerámica , Durapatita , Ensayo de Materiales , Itrio , Circonio , Animales , Durapatita/química , Circonio/química , Bovinos , Itrio/química , Cerámica/química , Dureza , Materiales Biocompatibles/química , Fenómenos Mecánicos
14.
J Dent ; 147: 105089, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38772449

RESUMEN

OBJECTIVE: The purpose of this systematic review and meta-analysis was to evaluate the accuracy (trueness and precision), marginal and internal adaptation, and margin quality of zirconia crowns made by additive manufacturing compared to subtractive manufacturing technology. METHODS: The investigation adhered to the PRISMA-ScR guidelines for systematic reviews and was registered at the Prospero database (n°CRD42023452927). Four electronic databases, including PubMed, Scopus, Embase, and Web of Science and manual search was conducted to find relevant studies published until September 2023. In vitro studies that assessed the trueness and precision, marginal and internal adaptation, and margin quality of printed crowns compared to milled ones were included. Studies on crowns over implants, pontics, temporary restorations, laminates, or exclusively experimental materials were excluded. RESULTS: A total of 9 studies were included in the descriptive reporting and 7 for meta-analysis. The global meta-analysis of the trueness (P<0.74,I2=90 %) and the margin quality (P<0.61,I2=0 %) indicated no significant difference between the root mean square of printed and milled zirconia crowns. The subgroup analysis for the printing system showed a significant effect (P<0.01). The meta-analysis of the crown areas indicated no significant difference in most of the areas, except for the marginal (favoring milled crowns) and axial (favoring printed crowns) areas. For precision and adaptation, both methods showed a clinically acceptable level. CONCLUSIONS: Additive manufacturing technology produces crowns with trueness and margin quality comparable to subtractive manufacturing. Both techniques have demonstrated the ability to produce crowns with precision levels, internal discrepancy, and marginal fit within clinically acceptable limits. CLINICAL SIGNIFICANCE: 3D printing emerges as a promising and potentially applicable alternative method for manufacturing zirconia crowns, as it shows trueness and margin quality comparable to restorations produced by the subtractive method.


Asunto(s)
Coronas , Adaptación Marginal Dental , Diseño de Prótesis Dental , Impresión Tridimensional , Circonio , Circonio/química , Humanos , Diseño de Prótesis Dental/métodos , Diseño Asistido por Computadora , Materiales Dentales/química
15.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38598918

RESUMEN

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Asunto(s)
Óxido de Aluminio , Cerámica , Ensayo de Materiales , Óxido de Aluminio/química , Cerámica/química , Propiedades de Superficie , Circonio/química , Diseño Asistido por Computadora , Materiales Dentales
16.
J Prosthet Dent ; 131(6): 1235.e1-1235.e8, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38594086

RESUMEN

STATEMENT OF PROBLEM: Additive (AM) and subtractive (SM) manufacturing have become popular for fabricating occlusal devices with materials of different chemical compositions. However, knowledge on the effect of material and antagonist type on the wear characteristics of occlusal devices fabricated by using different methods is limited. PURPOSE: The purpose of this in vitro study was to evaluate the effect of material and antagonist type on the wear of occlusal devices fabricated by using conventional manufacturing, AM, and SM. MATERIAL AND METHODS: Two-hundred and forty Ø10×2-mm disk-shaped specimens were fabricated by using heat-polymerized polymethylmethacrylate (control, CM), AM clear device resin fabricated in 3 different orientations (horizontal [AMH], diagonal [AMD], and vertical [AMV]), SM polymethylmethacrylate (SMP), and SM ceramic-reinforced polyetheretherketone (SMB) (n=40). Specimens were then divided into 4 groups based on the antagonists: steatite ceramic (SC); multilayered zirconia (ZR); lithium disilicate (EX); and zirconia-reinforced lithium silicate (ZLS) used for thermomechanical aging (n=10). After aging, the volume loss (mm3) and maximum wear depth (µm) were digitally evaluated. Data were analyzed with 2-way analysis of variance and Tukey honestly significant difference tests (α=.05). RESULTS: The interaction between the device material and the antagonist affected volume loss and maximum depth of wear (P<.001). AMH had volume loss and depth of wear that was either similar to or higher than those of other materials (P≤.044). When SC was used, CM had higher volume loss and depth of wear than AMV, and, when EX was used, AMD had higher volume loss and depth of wear than SMP (P≤.013). SC and ZR led to higher volume loss of CM and AMH than EX and led to the highest depth of wear for these materials, while ZR also led to the highest volume loss and depth of wear of AMD and AMV (P≤.019). EX led to the lowest volume loss and depth of wear of AMV and SMP and to the lowest depth of wear of AMH (P≤.021). Regardless of the antagonist, SMB had the lowest volume loss and depth of wear (P≤.005). CONCLUSIONS: AMH mostly had higher volume loss and depth of wear, while SMB had the lowest volume loss, and its depth of wear was not affected by the tested antagonists. ZR mostly led to higher volume loss and maximum depth of wear, while EX mostly led to lower volume loss and maximum depth of wear of the tested occlusal device materials.


Asunto(s)
Materiales Dentales , Ensayo de Materiales , Polimetil Metacrilato , Circonio , Materiales Dentales/química , Polimetil Metacrilato/química , Circonio/química , Cerámica/química , Humanos , Técnicas In Vitro , Ferulas Oclusales , Alisadura de la Restauración Dental , Diseño de Prótesis Dental , Benzofenonas , Porcelana Dental/química , Polímeros/química , Propiedades de Superficie , Polietilenglicoles/química , Cetonas/química
17.
Photobiomodul Photomed Laser Surg ; 42(5): 343-349, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38579157

RESUMEN

Objective: This in vitro study evaluates the shear bond strength (SBS) of yttria-stabilized tetragonal zirconia (Y-TZP) and resin cement after different surface treatments. Materials and methods: Forty-eight ceramic cubes were divided into four groups (n = 12): G1 (control) sandblasting with Al2O3; G2-sandblasting with silica-coated Al2O3 (Rocatec); G3-Rocatec + CO2 laser; and G4-CO2 laser + Rocatec. A metallic primer was applied to the pretreated ceramic. A rubber ring was adapted on the central area, and then, the resin cement was inserted into the matrix and photoactivated. The samples were evaluated regarding surface roughness (Ra), SBS, failure type, and qualitatively with scanning electron microscopy (SEM). The data were analyzed by one-way analysis of variance followed by Tukey's test (p < 0.05). Results: The mean values of Ra (µm) were as follows: G1-4.52a, G2-4.24a,b, G3-4.10a,b, and G4-2.90b and the mean values of SBS (MPa) were as follows: G1-7.84a , G2-4.41b , G3-4.61b and G4-6.14a,b. SEM analyses showed superficial irregularities for all groups, being more prominent for G1. The presence of silica deposits was observed for G2, G3, and G4, but in the last two groups there were some linear areas, promoted by the fusion of silica, due to the thermomechanical action of the CO2 laser. Conclusions: The surface treatment with CO2 laser + Rocatec, using one MDP-based cement, can be an alternative protocol for the adhesion cementation of Y-TZP ceramic since it was as effective as the conventional pretreatment with aluminum oxide sandblasting.


Asunto(s)
Cerámica , Recubrimiento Dental Adhesivo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie , Itrio , Circonio , Circonio/química , Itrio/química , Cementos de Resina/química , Cerámica/química , Recubrimiento Dental Adhesivo/métodos , Láseres de Gas , Técnicas In Vitro , Dióxido de Silicio/química , Óxido de Aluminio/química
18.
J Esthet Restor Dent ; 36(9): 1326-1336, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38665052

RESUMEN

OBJECTIVES: This study aimed to assess the influence of translucent monolithic versus bilayered crowns and whether the use of a CoCr base abutments affects the fatigue and fracture resistance of screwed implant-supported single crowns with external connections under mechanical cycling. MATERIALS AND METHODS: Fifty specimens were divided into groups: (1) metal-ceramic (MC) crown, (2) veneered zirconia crown (Zr), (3) veneered zirconia crown with a CoCr base abutment (ZrB), (4) monolithic translucent zirconia crown (MZr), and (5) monolithic translucent zirconia crown with a CoCr base abutment (MZrB). Specimens underwent mechanical cycling (5 × 106 cycles; 150 N) evaluating fatigue resistance (number of failures) and those that failed were subsequently subjected to fractographic analyses (stereomicroscope and scanning electron microscope) to evaluate failure location and area, and maximum fracture load was also measured. RESULTS: The failure-related survival rate (100%) and maximum fracture resistance of the MZrB were significantly higher than those of MC and Zr (50%; p < 0.05). There were no significant differences in the failure rate and fracture resistance when a CoCr base abutment was used or not in the translucent monolithic Zr groups (p > 0.05;MZrB vs. MZr). Failure location, with MC crowns' fractures, noted at the screw area (p = 0.043), while all-ceramic crowns were mostly in the cuspid and to failure area, the Zr group had the largest mean (15.55 ± 9.17 mm2) among the groups, significant difference only when compared with MC (1.62 ± 0.81 mm2) (p = 0.025). CONCLUSIONS: Translucent monolithic zirconia crowns exhibited significantly higher fatigue and fracture resistance compared with conventional MC and bilayered crowns. CLINICAL SIGNIFICANCE: The appropriate choice of material and manufacturing technique is crucial for predicting the higher clinical performance of single crowns. Enhanced mechanical resistance in terms of fatigue and fracture resistance can be achieved by replacing MC and bilayered restorations with computer-aided design and computer-aided manufacturing monolithic zirconia.


Asunto(s)
Coronas , Análisis del Estrés Dental , Circonio , Circonio/química , Cerámica/química , Diseño de Prótesis Dental , Fracaso de la Restauración Dental , Prótesis Dental de Soporte Implantado , Ensayo de Materiales , Humanos
19.
J Prosthodont ; 33(S1): 103-109, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38526464

RESUMEN

PURPOSE: This study evaluated the effect of toothbrushing cycles on surface roughness (Ra), gloss (GU), and morphology of two zirconia finishing and polishing protocols. MATERIALS AND METHODS: An ultra-translucent zirconia disc was sectioned into rectangular plates (12 mm × 7 mm × 3 mm) and divided into two groups according to the polishing and finishing system used (diamond rubber abrasive/DRA or glazing/GLA). Bovine enamel (BEN) plates with the same dimensions were used as a Control. Specimens of zirconia and enamel were analyzed for Ra and GU (n = 11) and surface morphology by scanning electron microscopy (n = 3) before toothbrushing (baseline) and after 15,000 and 30,000 toothbrushing cycles. Ra and GU data were analyzed by ANOVA two-way and post-hoc Tukey's test (α = 0.05), while the surface morphology was analyzed qualitatively. RESULTS: The Ra decreased significantly after 30,000 toothbrushing cycles for DRA and GLA zirconia ceramics. DRA showed a higher GU at the baseline, after 15,000 and 30,000 toothbrushing cycles than GLA and BEN. Toothbrushing polished the zirconia, creating a smooth surface, while no changes were observed for BEN. CONCLUSIONS: The increase in toothbrushing cycles (30,000) changed the surface roughness of DRA and GLA zirconia ceramics. DRA zirconia presented the highest GU, which did not change with toothbrushing.


Asunto(s)
Pulido Dental , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Cepillado Dental , Circonio , Circonio/química , Pulido Dental/métodos , Bovinos , Animales , Ensayo de Materiales , Materiales Dentales/química , Esmalte Dental , Cerámica/química
20.
Braz Dent J ; 35: e245581, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537011

RESUMEN

The objective is to evaluate the effect of different surface treatments and storage on the shear strength of ultratranslucent zirconia. 36 blocks of ultra-translucent zirconia were fabricated (7x7x2mm) and sintered. Then, divided into 12 groups according to the "surface treatment" (C -Primer; Al -Sandblasting with Al2O3 + Primer; Si -Silicate + Primer; Gl -Glaze + HF + Primer; Z -Zirlink; Zp -Zirlink + Primer) and "storage" factors (ST-with 150 days/37º and without). After surface treatment, five cylinders (Ø=2mm; h=2.0mm) of resin cement (n=15) were constructed in each ceramic block; at the end, the shear strength test was performed (1mm/min, 50Kgf), and analysis of surface failures. 60 additional samples (2x2x2mm) were made for extras analysis (surface roughness, MEV, and EDS). Bond strength and surface roughness data were statistically evaluated by ANOVA (2 factors/1 factor), Tukey test (5%), and Weibull analysis, respectively. ANOVA (2-way) revealed that all factors were statistically significant for bond strength. The silicatization groups (SiST: 30.47AMPa; Si: 29.21AMPa) showed the highest bond strength values, regardless of storage (Tukey's test). While the groups treated with Zirlink (ZST: 2.76FMPa; Z: 5.27EFMPa) showed the lowest values, just similar to the GlST group (5.14EFMPa). The Weibull modulus (m) showed a statistical difference between groups (p=0.000). ANOVA (1 factor) revealed that the "surface treatment" factor (p=0.0000) was statistically significant for surface roughness. Therefore, the application of Zirlink and Glaze on pre-sintered zirconia did not promote efficient adhesion of the ultratranslucent zirconia to the resin cement, even when associated with a primer containing MDP.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Circonio/química , Propiedades de Superficie , Ensayo de Materiales , Cerámica/química , Resistencia al Corte , Análisis del Estrés Dental
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA