Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 274
Filtrar
1.
Curr Eye Res ; 46(10): 1482-1488, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33745401

RESUMEN

Aim: To report the temperature differences on the ocular surface using infrared thermal imaging (TI) in thyroid eye disease (TED) and healthy eyesMethods: Prospective, consecutive, comparative case series comparing TI parameters between active and inactive TED with healthy controls. The data captured included baseline demography, activity of TED and the TI parameters. Area under the receiver operating characteristic curves (AUROC) were calculated for the temperature values to determine the sensitivity and specificity in distinguishing active from inactive TED. The Youden index and the predictor cut off values were also reported.Results: The study included 11 eyes with active TED, 46 eyes with inactive TED and 40 eyes healthy patients. Temperatures of pre-determined points on the ocular surface in degrees were compared between the three groups. Temperature at the caruncle, medial and lateral conjunctiva was noted to be significantly higher in the active TED group compared to inactive TED and healthy eyes. The most favorable Youden index (0.7) was noted for the caruncle with an AUROC value of 0.91, a sensitivity of 91% and a specificity of 79%. Correlation coefficient for the caruncular temperature with the corresponding CAS (clinical activity score) was 0.65 (95% C.I. 0.45 to 0.78, p < .0001).Conclusion: Thermal imaging in TED is an objective way of documenting surface inflammation by the surrogate marker of temperature change. It supplements CAS in clinically evident cases and could be useful in staging eyes with subtle clinical signs as well as those where signs have reduced following initiation of treatment.


Asunto(s)
Temperatura Corporal/fisiología , Conjuntiva/fisiología , Córnea/fisiología , Párpados/fisiología , Oftalmopatía de Graves/fisiopatología , Órbita/fisiología , Termografía/métodos , Adulto , Área Bajo la Curva , Femenino , Voluntarios Sanos , Humanos , Rayos Infrarrojos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Sensibilidad y Especificidad
2.
Prev Vet Med ; 186: 105225, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33348303

RESUMEN

The world's growing population is becoming increasingly centred around large cities, affording opportunities for peri-urban food production. Goats are well-suited to conversion of resources that are available in peri-urban settings into meat and occasionally milk. Haemonchus contortus has been described as "the nemesis of small ruminant production systems in tropical and subtropical regions"; hence control of haemonchosis through planned animal health management affords a pragmatic first step in improving the production efficiency of peri-urban goats. This study of peri-urban goat production investigated the potential value of targeted selective treatment of haemonchosis. 452 peri-urban goat keepers in southern Malawi were visited during three seasonal periods with relevance to the epidemiology of haemonchosis. 622, 599 and 455 individually identified goats were clinically examined during the dry season, the rainy season, and shortly after the end of the rainy season, respectively. Data were recorded for sex, age, weight, conjunctival mucous membrane colour score (FAMACHA©), body condition score (BCS) and faecal worm egg count (FEC); and where possible for pregnancy and lactation status. Animals with pale ocular mucous membranes were treated with 10 mg/kg albendazole, then re-examined 14 days later. Animals with pink mucous membranes, but FECs ≥250 eggs per gram were also re-examined and treated 14 days later. The results show high variability in growth rates deduced from the ages and bodyweights of each of 999 goats at the time of their enrolment. FAMACHA© scores alone were a poor index for the targeted selective treatment of haemonchosis, because they failed to identify too many animals that would have required treatment at different times of year and using different FAMACHA© and FEC cut-offs. Combining the indices of FAMACHA© scores ≥4, body condition scores ≥2, and age >18 months was more reliable in identifying those animals requiring treatment when different epidemiologically-relevant FEC thresholds for different seasons were taken into account. Inclusion of late pregnancy or early lactation status would have resulted in very few animals requiring treatment being missed. The use of conjunctival mucous membrane colour scoring in this way provided a valuable insight of the general health status of the peri-urban goats, to create opportunities for planned animal health management to improve productivity. The efficacy of albendazole treatment was poor, putatively due to drug resistance, or poor drug bioavailability in goats. In summary, our study shows opportunities for better production efficiency in peri-urban goats, and demonstrates the value of simple clinical diagnostic indices as decision support tools in planned animal health management.


Asunto(s)
Antihelmínticos/administración & dosificación , Conjuntiva/fisiología , Resistencia a Medicamentos , Enfermedades de las Cabras/tratamiento farmacológico , Cabras/fisiología , Hemoncosis/veterinaria , Animales , Color , Femenino , Enfermedades de las Cabras/parasitología , Hemoncosis/tratamiento farmacológico , Hemoncosis/parasitología , Haemonchus/fisiología , Malaui , Masculino , Membrana Mucosa/fisiología
3.
Exp Eye Res ; 200: 108211, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32890481

RESUMEN

The main purpose of this study is to evaluate the diagnostic role of Toll-like receptors 2 (TLR2) and 4 (TLR4) expression in corneal and conjunctival epithelial cells of eyes with pellucid marginal degeneration (PMD) compared to keratoconus patients (KC) and control subjects. A prospective case-control study in 29 PMD eyes, 109 KC eyes and 72 healthy eyes was done. All participants were subjected to a clinical, topographic, aberrometric and tomographic exam with extraction of corneal and conjunctival epithelial cells through scraping. The TLR2 and TLR4 expression was measured with flow cytometry. Receiver operating characteristic (ROC) curve analysis was used to determine the most appropriate cutoff point for predicting the risk of PMD and KC. Correlations between TLR2/TLR4 expression and the severity of PMD/KC were evaluated. A TLRs follow-up review was made 19 ± 4 months after to the first review. As result, mean expression of TLR2 and TLR4 in both corneal and conjunctival epithelial cells was significantly higher in eyes with corneal ectasia (PMD and KC) than in control eyes (all p < 0.05). Conjunctival TLR4 expression showed the highest capacity to diagnose the existence of PMD (odd ratio 42.84; 95% confidence interval:6.20-296.20; p < 0.0001) after adjusting by eye rubbing and steeper corneal meridian. Moreover, we found an association between the TLR2/TLR4 overexpression with the severity of the PMD and KC measured by corneal topographic, aberrometric and tomographic quantitative parameters (all p < 0.05). Differences on TLR2/TLR4 expression between study groups were maintained during the follow-up period. In conclusion, the TLR2/TLR4 overexpression in corneal and conjunctival epithelial cells of PMD and KC patients compared to healthy control subjects have demonstrated their role as diagnostic target in both corneal ectatic disorders.


Asunto(s)
Conjuntiva/fisiología , Córnea/patología , Regulación de la Expresión Génica , Queratocono/diagnóstico , ARN/genética , Adolescente , Adulto , Anciano , Niño , Conjuntiva/metabolismo , Córnea/metabolismo , Topografía de la Córnea , Femenino , Humanos , Queratocono/genética , Queratocono/metabolismo , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Receptores Toll-Like/biosíntesis , Receptores Toll-Like/genética , Adulto Joven
4.
J Ocul Pharmacol Ther ; 36(9): 679-685, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32721249

RESUMEN

Objective: The purpose of this study was to evaluate the potential of voclosporin (VOS) in preventing goblet cell (GC) loss and modulating interferon-gamma (IFN-γ) producing CD4+ T cells in the mouse desiccating stress (DS) dry eye model. Methods: Mice were subjected to DS and treated topically with vehicle, VOS, or cyclosporine A as a treatment control. Corneal barrier function was evaluated after 5 and conjunctival GC density after 10 days of desiccation. CD4+ T cells were isolated from ocular surface draining lymph nodes of dry eye donor mice and adoptively transferred into immune deficient RAG1-/- mice from which tears and conjunctiva were collected for the evaluation of inflammatory cytokines/chemokines and GC density. Results: Compared to the vehicle-treated group, VOS was significantly better in preserving corneal barrier function and preventing DS-induced conjunctival GC loss. CD4+ T cells from VOS treated dry eye donors caused less conjunctival GC loss than vehicle and suppressed expression of IFN-γ signature genes to a similar extent and transforming growth factor-beta to a greater extent than cyclosporine in adoptive transfer recipients. Conclusion: These findings suggest that VOS preserves corneal barrier function and conjunctival GCs and suppresses IFN-γ producing CD4+ T cells in experimental dry eye.


Asunto(s)
Inhibidores de la Calcineurina/uso terapéutico , Córnea/efectos de los fármacos , Ciclosporina/uso terapéutico , Modelos Animales de Enfermedad , Síndromes de Ojo Seco/tratamiento farmacológico , Células Caliciformes/efectos de los fármacos , Traslado Adoptivo/métodos , Animales , Linfocitos T CD4-Positivos/efectos de los fármacos , Linfocitos T CD4-Positivos/fisiología , Inhibidores de la Calcineurina/farmacología , Conjuntiva/efectos de los fármacos , Conjuntiva/fisiología , Córnea/fisiología , Ciclosporina/farmacología , Síndromes de Ojo Seco/inducido químicamente , Síndromes de Ojo Seco/fisiopatología , Femenino , Células Caliciformes/fisiología , Ratones , Ratones Endogámicos C57BL , Escopolamina/toxicidad
5.
Sci Rep ; 10(1): 9083, 2020 06 03.
Artículo en Inglés | MEDLINE | ID: mdl-32493941

RESUMEN

Conditional gene targeting in mice by means of Cre-loxP strategy represents a powerful approach to study mammalian gene function. This approach is however dependent on the availability of suitable strains of mice with a tissue or time restricted activity of the Cre recombinase. Here we describe Aldh3-Cre transgenic mice as a useful tool to conditionally delete genes in cornea, a specialized transparent tissue found on the anterior-most part of the eye, which acts as a protective barrier and contributes to the refractive power. Using a set of floxed alleles we demonstrate high Aldh3-Cre activity in corneal epithelial cells, corneal stroma and conjunctival epithelial cells at postnatal stages. Aldh3-Cre will thus be particularly beneficial for functional analysis of genes which are vital for postnatal development of cornea and conjunctiva.


Asunto(s)
Aldehído Deshidrogenasa/genética , Córnea/fisiología , Integrasas/genética , Ratones Transgénicos/genética , Ratones Transgénicos/fisiología , Alelos , Animales , Conjuntiva/fisiología , Células Epiteliales/fisiología , Eliminación de Gen , Marcación de Gen/métodos , Ratones
6.
PLoS One ; 14(12): e0226042, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31815965

RESUMEN

Workers in the dry-cleaning industry are exposed to organic solvents that may cause eye irritation and tear film changes. Objective To quantify changes in the ocular surface and tear film in dry cleaners exposed to organic solvents and associate these changes with ocular irritation as reported in a symptom questionnaire for dry eye diagnosis. Methods This was a case and control study in which the characteristics and eye-irritation symptoms were compared between two groups of 62 participants that were either exposed or not exposed to organic solvents. A general optometric examination and the following test were performed: lipid interferometry, Lissamine Green Stain, tear breakup time, Schirmer I, conjunctival impression cytology and the Donate dry eye symptoms questionnaire. Results Sixty-five percent of exposed workers obtained a higher score than 13 on the Donate dry eye symptoms questionnaire which indicated the presence of more irritation symptoms than those in the non- exposed group. A Chi-square analysis indicated the exposed group reported significantly higher incidences (P <0.005) for eye irritation symptoms of sandy sensation; tearing eyes sensation; foreign body sensation; tearing; dry eye; dryness; eyestrain and heavy eyelids. A Mann Whitney-U indicated greater severity only for symptoms relating to dry eye; sandy sensation; foreign body sensation, tearing; tearing eyes and dryness. There was a statistically significant difference (P <0.05) for Schirmer I; tear break up time; and the ocular surface assessed with Lissamine green staining and conjunctival impression cytology between groups. A reduction in the thickness of the lipid layer in the exposed group compared to the non-exposed group was observed. Surprisingly, clinical test outcomes were not significantly correlated with dry eye symptoms nor years of exposure. Conclusion Workers in the dry-cleaning industry exposed to organic solvents are associated with changes in ocular surface and tear film generating irritation symptoms commonly present in evaporative dry eye.


Asunto(s)
Conjuntiva/efectos de los fármacos , Síndromes de Ojo Seco/diagnóstico , Compuestos Orgánicos/toxicidad , Solventes/química , Lágrimas/efectos de los fármacos , Adolescente , Adulto , Astenopía/etiología , Estudios de Casos y Controles , Conjuntiva/patología , Conjuntiva/fisiología , Síndromes de Ojo Seco/etiología , Párpados/efectos de los fármacos , Párpados/fisiopatología , Femenino , Humanos , Lavandería , Lípidos/química , Masculino , Exposición Profesional , Compuestos Orgánicos/química , Lágrimas/química , Lágrimas/fisiología , Adulto Joven
7.
Adv Exp Med Biol ; 1161: 13-25, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31562618

RESUMEN

The present review focuses on the role of one of the D-series resolvins (Rv) RvD1 in the regulation of conjunctival goblet cell secretion and its role in ocular surface health. RvD1 is the most thoroughly studied of the specialized proresolution mediators in the goblet cells. The anterior surface of the eye consists of the cornea (the transparent central area) and the conjunctiva (opaque tissue that surrounds the cornea and lines the eyelids). The secretory mucin MUC5AC produced by the conjunctival goblet cells is protective of the ocular surface and especially helps to maintain clear vision through the cornea. In health, a complex neural reflex stimulates goblet cell secretion to maintain an optimum amount of mucin in the tear film. The specialized pro-resolution mediator, D-series resolvin (RvD1) is present in human tears and induces goblet cell mucin secretion. RvD1 interacts with its receptors ALX/FPR2 and GPR32, activates phospholipases C, D, and A2, as well as the EGFR. This stimulation increases the intracellular [Ca2+] and activates extracellular regulated kinase (ERK) 1/2 to cause mucin secretion into the tear film. This mucin secretion protects the ocular surface from the challenges in the external milieu thus maintaining a healthy interface between the eye and the environment. RvD1 forms a second important mechanism along with activation of a neural reflex pathway to regulate goblet cell mucin secretion and protect the ocular surface in health.


Asunto(s)
Conjuntiva , Córnea , Ácidos Docosahexaenoicos , Fenómenos Fisiológicos Oculares , Conjuntiva/citología , Conjuntiva/fisiología , Córnea/fisiología , Ácidos Docosahexaenoicos/metabolismo , Células Caliciformes/metabolismo , Humanos
8.
Clin Exp Ophthalmol ; 47(7): 892-897, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31074572

RESUMEN

IMPORTANCE: To illustrate the importance of lymphatic drainage in assessing trabeculectomy bleb function using intracameral trypan blue. BACKGROUND: To study the lymphatic drainage of trabeculectomy blebs using trypan blue, correlate with bleb function and classify them accordingly. DESIGN: Prospective cross-sectional study in a tertiary care centre. PARTICIPANTS: Thirteen glaucoma patients post-trabeculectomy were studied. METHODS: Trypan blue was injected into the anterior chamber. MAIN OUTCOME MEASURES: The duration taken for dye to stain a drainage bleb or lymphatics is recorded. The extent of the lymphatic structures were measured in clock hours. Intraocular pressure (IOP) prior to surgery was recorded. RESULTS: Eight post-trabeculectomy subjects with dye stained lymphatic vessels had lower IOP (12.6 mmHg, P = .013) compared to the five with no lymphatic vessel staining (mean IOP 23.6 mmHg). Lymphatic extent was inversely related to IOP (P = .021). CONCLUSIONS AND RELEVANCE: Eyes with lymphatic connections to drainage blebs had lower IOP and reduced requirement for topical medications. The extent of lymphatic connection to drainage blebs is related to lower IOP.


Asunto(s)
Colorantes/administración & dosificación , Conjuntiva/fisiología , Glaucoma/cirugía , Sistema Linfático/fisiología , Vasos Linfáticos/fisiología , Trabeculectomía , Azul de Tripano/administración & dosificación , Anciano , Anciano de 80 o más Años , Cámara Anterior/efectos de los fármacos , Estudios Transversales , Femenino , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tonometría Ocular
9.
Eye Contact Lens ; 45(4): 246-253, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30383547

RESUMEN

OBJECTIVES: We aim to use the ovariectomized cynomolgus monkey to observe the effect of long-term changes of sex hormone levels on ocular surface. METHODS: Six healthy adolescent cynomolgus monkeys were randomly assigned to control and experimental groups (n=3/group). Bilateral ovariectomy was performed in experimental group, and sham operation was performed on control animals with their ovaries reserved. The concentrations of serum estradiol and testosterone in cynomolgus monkeys' lower-limb venous were detected by radioimmunoassay before surgery, and at 6, 12, 18, and 24 months after the surgery. Phenol red cotton thread test, tear osmolarity, corneal fluorescein staining, and conjunctival impression cytology were performed to evaluate the ocular surface conditions before surgery, and at 6, 12, 18, and 24 months after the surgery. The histological examinations of the bulbar conjunctiva and labial glands tissues were performed at 12 and 24 months after the surgery. RESULTS: There were no significant differences in the serum level of estradiol and testosterone between the experimental and control groups before surgery, at 6, and 12 months after surgery (P>0.05). Serum level of estradiol and testosterone were significantly less in experimental versus control group at 18 and 24 months after surgery (P<0.05). There was no significant differences in phenol red cotton between the experimental and control groups before surgery, at 6, 12, 18, and 24 months after surgery (P>0.05). Tear osmolarity had no significant differences between experimental and control group before surgery (P>0.05), and it was significantly higher in experimental versus control group at all four time-points after surgery (P<0.05). The number of conjunctival goblet cells had no significant differences between experimental and control group before surgery, at 6 months after surgery (P>0.05), and it was significantly lower in experimental versus control group at 12, 18, and 24 months after surgery (P<0.05). There were no significant differences in the corneal fluorescein staining score between the experimental and control groups before surgery, at 6, 12, and 18 months after surgery (P>0.05), and it was higher in experimental than control group at 24 months after surgery (P<0.05). In addition, inflammatory cell infiltration in bulbar conjunctiva and labial glands tissues was observed in experimental group and was unobserved in control group at 24 months after surgery. CONCLUSIONS: Ovariectomy led to decreased sex hormone levels in cynomolgus monkey. In turn, tear osmolarity was increased, the number of conjunctival goblet cells were decreased, the corneal fluorescence staining was increased, and the pathological examination of the bulbar conjunctiva and labial glands tissues were abnormal, phenol red cotton thread test did not change significantly.


Asunto(s)
Conjuntiva/fisiología , Córnea/fisiología , Estradiol/sangre , Células Caliciformes/citología , Ovariectomía , Testosterona/sangre , Animales , Conjuntiva/citología , Córnea/citología , Femenino , Macaca fascicularis , Concentración Osmolar , Radioinmunoensayo , Lágrimas/química , Lágrimas/fisiología
10.
Invest Ophthalmol Vis Sci ; 59(14): DES169-DES173, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30481823

RESUMEN

Dry eye is a multifactorial disease that is one of the most common diseases worldwide. A major cause of dry eye is the deficiency of aqueous tears, which are mainly secreted from the lacrimal gland. The lacrimal gland plays an important role in maintaining the health of the ocular surface and protecting it from environmental exposure. Dry eye can lead to ocular irritation and discomfort, as well as severe ocular surface diseases (e.g., ocular infections, corneal ulcerations, and ocular surface keratinization). These severe diseases can be induced by an atrophied or injured lacrimal gland; current therapies cannot completely restore the function of lacrimal gland. To develop more definitive therapies, it is important to understand lacrimal gland biology at the molecular level, as well as inflammatory processes affecting the function of the gland. During severe inflammation, the tissue structure of the lacrimal gland is destroyed; it is replaced by scar formation during wound healing, which leads to lacrimal gland dysfunction. Using an animal model of lacrimal gland dysfunction, many investigators have studied molecular mechanisms of inflammation in the lacrimal gland. To restore lacrimal gland function, the lacrimal acini must be restored in their niche. Notably, organ transplantation therapies have been reported to restore lacrimal gland function, directly or indirectly, in animal models. In this review, we describe the current understanding of the lacrimal gland as the therapeutic target for dry eye diseases, as well as recent advances in the field of lacrimal gland cell-based therapy to treat severe dry eye diseases.


Asunto(s)
Conjuntiva/fisiología , Síndromes de Ojo Seco/fisiopatología , Epitelio Corneal/fisiología , Aparato Lagrimal/fisiología , Regeneración/fisiología , Animales , Dacriocistitis/fisiopatología , Estado de Salud , Humanos
11.
Ocul Surf ; 16(4): 424-429, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29883739

RESUMEN

PURPOSE: To investigate the influence of blinking on tear film parameters, ocular surface characteristics, and dry eye symptomology. METHODS: A total of 154 participants were recruited in an age, gender and ethnicity-matched cross-sectional study, of which 77 exhibited clinically detectable incomplete blinking, and 77 did not. Blink rate, dry eye symptomology, tear film parameters, and ocular surface characteristics were assessed in a single clinical session. RESULTS: Overall, a higher proportion of participants exhibiting incomplete blinking fulfilled the TFOS DEWS II dry eye diagnostic criteria (64% versus 44%, p = 0.02), with an odds ratio (95% CI) of 2.2 (1.2-4.2) times. Participants exhibiting incomplete blinking had higher Ocular Surface Disease Index scores (18 ±â€¯13 versus 12 ±â€¯9, p = 0.01), and greater levels of meibomian gland dropout (41.3 ±â€¯15.7% versus 27.5 ±â€¯14.1%, p < 0.001). Furthermore, poorer tear film lipid layer thickness, non-invasive tear film stability, expressed meibum quality, eyelid notching, and anterior blepharitis grades were also observed in those exhibiting incomplete blinking (all p < 0.05). Blink frequency did not correlate significantly with any ocular surface parameters (all p > 0.05). CONCLUSIONS: Incomplete blinking was associated with a two-fold increased risk of dry eye disease. The greater levels of meibomian gland dropout, as well as poorer expressed meibum quality and tear film lipid layer thickness, observed would suggest that incomplete blinking may predispose towards the development of evaporative dry eye.


Asunto(s)
Parpadeo/fisiología , Conjuntiva/fisiología , Córnea/fisiología , Lágrimas/fisiología , Adulto , Anciano , Blefaritis/fisiopatología , Conjuntiva/fisiopatología , Córnea/fisiopatología , Estudios Transversales , Síndromes de Ojo Seco/fisiopatología , Femenino , Humanos , Lípidos/análisis , Masculino , Glándulas Tarsales/patología , Persona de Mediana Edad , Oportunidad Relativa
12.
Clin Exp Optom ; 101(2): 188-192, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29023989

RESUMEN

BACKGROUND: To evaluate the impact on the ocular surface of a daily disposable hydrogel contact lens with high water content compared with two silicone hydrogel daily disposable lenses of lower water content. METHODS: The hydrogel lens assessed was made from nesofilcon A and the silicone hydrogel lenses were made of delefilcon A and stenfilcon A. Contact lens thickness was measured to assess material stability during daily wear, and ocular surface parameters such as tear film osmolarity, tear meniscus area and central corneal thickness were also assessed. Optical quality was analysed for all cases by means of wavefront aberrometry. RESULTS: The nesofilcon A was shown to be the thinnest lens (p < 0.001), while no differences in lens thickness were found between the two silicone hydrogel lenses (p = 0.495). No significant differences were found in tear film osmolarity, tear meniscus area, central corneal thickness or corneal aberrations, either as a function of the lens measured or time of use (p > 0.05). CONCLUSION: In spite of having the thinnest lens and the highest water content, the hydrogel does not significantly impact on tear film and corneal swelling after one day of use in first-time wearers.


Asunto(s)
Conjuntiva/fisiología , Lentes de Contacto Hidrofílicos , Córnea/fisiología , Hidrogel de Polietilenoglicol-Dimetacrilato , Miopía/terapia , Diseño de Prótesis , Lágrimas/química , Adulto , Equipos Desechables , Diseño de Equipo , Femenino , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Masculino , Concentración Osmolar , Propiedades de Superficie , Adulto Joven
13.
Curr Eye Res ; 42(12): 1574-1584, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29111837

RESUMEN

PURPOSE: This review examines the evidence for and significance of pre-conjunctival tear temperature being higher than central pre-corneal temperature with associated more rapid evaporation of warmer pre-conjunctival tears in normal eyes but especially in hyperemic dry eye disease. METHODS: PubMed searches using the terms "evaporative dry eye," "conjunctival tear evaporation," "tear evaporation," and "dry eye conjunctival hyperemia" indicated 157, 49, 309, and 96 potentially relevant papers, respectively. Selections from these lists were the basis for examining the significance of the evidence relevant to pre-conjunctival tear layer temperature and evaporation. RESULTS: There is evidence supporting an amplifying inflammatory and para-inflammatory hyperemia dry eye cascade, which increases pre-conjunctival tear temperature and the risk of accelerated pre-conjunctival tear evaporation with exacerbated osmolarity elevation and inflammation. Dry eye cascade amplification is consistent with increases in symptoms and inflammatory as well as para-inflammatory hyperemia toward the end of the waking day. Apart from age-related conjunctivochalasis, dry eye-related conjunctival epithelial cell pathology including reduced goblet cell numbers and associated mucin deficiency, squamous metaplasia, and increased separation of cell layers could help to destabilize tears and facilitate evaporation as part of an amplifying cascade. CONCLUSIONS: Greater difficulty in assessing conjunctival tear break up may contribute to an underestimation of a role for faster evaporation of pre-conjunctival tears in dry eye disease and help explain any non-correspondence between symptoms and corneal signs of dry eye disease. Success with anti-inflammatory therapies for dry eye disease may be at least partly due to reductions in conjunctival hyperemia and deamplification of evaporative cascades. Conjunctival inflammatory hyperemia in other diseases may contribute to accelerated pre-conjunctival tear evaporation and the risk of tear-deficiency- associated exacerbation of those diseases including impaired responses to therapeutic approaches to them. Similarly, postsurgical conjunctival inflammation and associated acceleration of tear evaporation could contribute to delayed wound healing.


Asunto(s)
Temperatura Corporal/fisiología , Conjuntiva/fisiología , Conjuntivitis/diagnóstico , Síndromes de Ojo Seco/diagnóstico , Hiperemia/diagnóstico , Lágrimas/química , Humanos , Inflamación/diagnóstico , Concentración Osmolar , Vapor
14.
J Korean Med Sci ; 32(4): 666-671, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28244295

RESUMEN

We evaluated the safety of matrix metalloproteinase (MMP) inhibitor in experimental glaucoma filtration surgery in an animal model. Fifteen New Zealand white rabbits underwent an experimental trabeculectomy and were randomly allocated into 3 groups according to the adjuvant agent: no treatment group (n = 5), 0.02% mitomycin C (MMC) soaking group (n = 5), and MMP inhibitor (ilomastat) subconjunctival injection group (n = 5). Slit lamp examination with Seidel testing, pachymetry, and specular microscopy was performed preoperatively and postoperatively. The conjunctiva and ciliary body toxicity were evaluated with scores according to the pathologic grading systems. Electron microscopy was used to examine the structural changes in cornea, conjunctiva, and ciliary body. In the ilomastat-treated group, there was no statistically significant change in central corneal thickness preoperatively and at 28 days postoperatively (P = 0.655). There were also no significant changes in specular microscopy findings over the duration of the study in the ilomastat-treated group. The conjunctival toxicity score was 1 in the control group, 1.5 in the ilomastat-treated group, and 2 in the MMC-treated group. When assessing ciliary body toxicity scores, the ilomastat-treated group score was 0.5 and the MMC-treated group score was 1.5. Transmission electron microscopy did not show structural changes in the cornea and ciliary body whereas the structural changes were noticed in MMC group. A single subconjunctival injection of MMP inhibitor during the experimental trabeculectomy showed a less toxic affect in the rabbit cornea, conjunctiva, and ciliary body compared to MMC.


Asunto(s)
Conjuntiva/efectos de los fármacos , Glaucoma/cirugía , Indoles/toxicidad , Inhibidores de la Metaloproteinasa de la Matriz/toxicidad , Animales , Cuerpo Ciliar/efectos de los fármacos , Cuerpo Ciliar/fisiología , Conjuntiva/fisiología , Córnea/efectos de los fármacos , Córnea/fisiología , Ácidos Hidroxámicos , Microscopía Electrónica de Transmisión , Mitomicina/toxicidad , Conejos , Trabeculectomía
15.
Eye Contact Lens ; 43(6): 346-351, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27203795

RESUMEN

OBJECTIVE: To evaluate the ocular surface temperature using an infrared thermography camera before and after wearing scleral lens in patients with keratoconus and correlate these results with the tear production and stability. METHODS: A pilot, experimental, short-term study has been performed. Twenty-six patients with keratoconus (36.95±8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (KC-ICRS group) and patients without ICRS (KC group). Schirmer test, tear breakup time (TBUT), and ocular surface temperature in the conjunctiva, limbus, and cornea were evaluated before and after wearing a scleral lens. RESULTS: The patients wore the scleral lenses from 6 to 9 hours with average of 7.59±0.73 hours. No significant changes in Schirmer test and TBUT were found for both groups. No temperature differences were found between the KC-ICRS and the KC groups for all zones evaluated. There was a slight, but statistically significant, increase in the inferior cornea, temporal limbus, and nasal conjunctival temperature for KC-ICRS group and temporal limbus temperature decreasing for the KC group after wearing scleral lens (P<0.05). The conjunctiva and limbus temperature was statistically higher than the central cornea for both groups before and after scleral lenses wearing (P<0.05), but no difference in the peripheral cornea was found. No statistically significant differences in the central corneal temperature were found between the groups after scleral lens wearing (P>0.05). CONCLUSION: Scleral contact lens seems not to modify the ocular surface temperature despite the presence of the tear film stagnation under the lens.


Asunto(s)
Temperatura Corporal/fisiología , Conjuntiva/fisiología , Lentes de Contacto , Córnea/fisiología , Queratocono/terapia , Prótesis e Implantes , Esclerótica , Adulto , Femenino , Humanos , Queratocono/metabolismo , Limbo de la Córnea/fisiología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estudios Prospectivos , Lágrimas/metabolismo , Termografía/métodos
16.
Eye Contact Lens ; 43(4): 240-244, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27171131

RESUMEN

OBJECTIVES: To investigate the utility of Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) scleral lenses in patients with exposure keratopathy, with outcomes based on changes in visual acuity, visual function, and corneal staining. METHODS: A retrospective interventional case series of patients evaluated and treated from September 2009 through June 2014 at a single multi-specialty institutional practice. Eighteen of 29 patients with exposure keratoconjunctivitis, lagophthalmos, ectropion, or lid retraction, referred to USC Eye Institute after failing conventional therapies completed PROSE scleral lens fitting and were included in the study. Visual function was assessed before and after PROSE fitting with the Ocular Surface Disease Index (OSDI) survey. Visual acuity (VA) and corneal staining changes were also evaluated before and after treatment. RESULTS: Visual acuity improved from 0.60±0.68 logMAR pre-PROSE to 0.25±0.34 logMAR (Z=-3.81, P=0.00014) post-PROSE, which corresponds to an improvement of about 20/80 to 20/35 on Snellen VA. Ocular Surface Disease Index scores improved from 56.54±29.75 pre-PROSE to 24.98±21.23 post-PROSE (Z=-2.98, P=0.0029), and corneal staining values decreased from 2.17±0.84 pre-PROSE to 0.64±0.70 post-PROSE (Z=-3.27, P=0.011). CONCLUSIONS: The results suggest that PROSE scleral lens therapy is effective in patients with exposure keratopathy who had failed conventional therapies and can serve as an alternative to lid surgery.


Asunto(s)
Conjuntiva/fisiología , Lentes de Contacto , Enfermedades de la Córnea/terapia , Síndromes de Ojo Seco/terapia , Ecosistema , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades de la Córnea/etiología , Enfermedades de la Córnea/fisiopatología , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/fisiopatología , Enfermedades de los Párpados/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ajuste de Prótesis , Refracción Ocular/fisiología , Estudios Retrospectivos , Propiedades de Superficie , Agudeza Visual/fisiología
17.
J Tissue Eng Regen Med ; 11(3): 896-904, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-25676608

RESUMEN

Ocular surface disorders, such as pterygium, cicatricial pemphigoid and external disruptions, can cause severe inflammation, scarring, fornix shortening as well as ankyloblepharon. Current treatments do not resolve these conditions sufficiently. The aim of this study was to evaluate clinical applicability and suitability of plastic compressed collagen to serve as a substrate for the expansion of human conjunctival epithelial cells in order to develop an epithelialized conjunctival substitute for fornix reconstruction. Human conjunctival epithelial cells were expanded on plastic compressed collagen gels. Epithelial cell characteristics were evaluated by haematoxylin and eosin staining, electron microscopy and cytokeratin expression. The expression of putative epithelial progenitor cell markers p63α, ABCG2 and CK15 was assessed by immunostaining. The proliferative capacity and clonal growth of the cells was evaluated before (P0) and after expansion (P1) on the plastic compressed collagen gels by colony forming efficiency assay. The potential clinical applicability of this gel substitutes was evaluated by assessment of their biomechanical properties as well as their surgical handling. Human conjunctival epithelial cells cultured on plastic and plastic compressed collagen gels formed a confluent cell layer and expressed CK19. The cells showed expression of the putative epithelial progenitor cell markers p63α, ABCG2 and CK15 and sustained colony forming ability. The compressed collagen gels showed a high ultimate tensile strength and elasticity and the surgical handling of gels was comparable to amniotic membrane. An epithelialized conjunctival tissue construct on the basis of compressed collagen might therefore be a promising alternative bioartificial tissue substitute for conjunctival reconstruction. Copyright © 2015 John Wiley & Sons, Ltd.


Asunto(s)
Colágeno/farmacología , Conjuntiva/fisiología , Plásticos/farmacología , Células 3T3 , Animales , Fenómenos Biomecánicos , Proliferación Celular/efectos de los fármacos , Forma de la Célula/efectos de los fármacos , Ensayo de Unidades Formadoras de Colonias , Células Epiteliales/citología , Células Epiteliales/efectos de los fármacos , Células Epiteliales/ultraestructura , Humanos , Inmunohistoquímica , Ratones , Conejos , Ratas , Resistencia a la Tracción
18.
Artículo en Inglés | MEDLINE | ID: mdl-26927466

RESUMEN

AIMS: To assess the impact of autologous serum eye drops on the level of ocular surface apoptosis in patients with bilateral severe dry eye disease. METHODS: This prospective study was conducted on 10 patients with severe dry eye due to graft versus host disease (group 1) and 6 patients with severe dry eye due to primary Sjögren's syndrome (group 2). Impression cytology specimens from the bulbar conjunctiva were obtained before and after a three-month treatment with 20% autologous serum eye drops applied a maximum of 12 times a day together with regular therapy with artificial tears. The percentage of apoptotic epithelial cells was evaluated immunochemically using anti-active caspase 3 antibody. RESULTS: In group 1, the mean percentage of apoptotic cells was 3.6% before the treatment. The three-month treatment led to a significant decrease to a mean percentage of 1.8% (P = 0.028). The mean percentage of apoptotic conjunctival cells decreased from 5.4% before the treatment to 3.8% in group 2; however, these results did not reach the level of significance. CONCLUSION: Three-month autologous serum treatment led to the improvement of ocular surface apoptosis, especially in the group of patients with severe dry eye due to graft versus host disease. This result supports the very positive effect of autologous serum on the ocular surface in patients suffering from severe dry eye.


Asunto(s)
Apoptosis/fisiología , Conjuntiva/fisiología , Síndromes de Ojo Seco/terapia , Soluciones Oftálmicas/administración & dosificación , Suero , Síndromes de Ojo Seco/fisiopatología , Células Epiteliales/fisiología , Enfermedad Injerto contra Huésped/fisiopatología , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Estudios Prospectivos
20.
J Electromyogr Kinesiol ; 28: 23-30, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26990614

RESUMEN

Upper eyelid movement depends on the antagonistic actions of orbicularis oculi muscle and levator aponeurosis. Blepharoptosis is an abnormal drooping of upper eyelid margin with the eye in primary position of gaze. Transconjunctival incisions for upper eyelid ptosis correction have been a well-developed technique. Conventional prognosis however depends on clinical observations and lacks of quantitatively analysis for the eyelid muscle controlling. This study examines the possibility of using the assessments of temporal correlation in surface electromyography (SEMG) as a quantitative description for the change of muscle controlling after operation. Eyelid SEMG was measured from patients with blepharoptosis preoperatively and postoperatively, as well as, for comparative study, from young and aged normal subjects. The data were analyzed using the detrended fluctuation analysis method. The results show that the temporal correlation of the SEMG signals can be characterized by two indices associated with the correlation properties in short and long time scales demarcated at 3ms, corresponding to the time scale of neural response. Aging causes degradation of the correlation properties at both time scales, and patient group likely possess more serious correlation degradation in long-time regime which was improved moderately by the ptosis corrections. We propose that the temporal correlation in SEMG signals may be regarded as an indicator for evaluating the performance of eyelid muscle controlling in postoperative recovery.


Asunto(s)
Blefaroptosis/diagnóstico , Blefaroptosis/cirugía , Conjuntiva/cirugía , Electromiografía/métodos , Cuidados Posoperatorios/métodos , Adulto , Anciano , Anciano de 80 o más Años , Blefaroplastia/métodos , Blefaroptosis/fisiopatología , Conjuntiva/fisiología , Párpados/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculos Oculomotores/fisiología , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...