Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.164
Filtrar
1.
BMC Oral Health ; 24(1): 501, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38725023

RESUMEN

BACKGROUND: Releasing of metal ions might implicate in allergic reaction as a negative subsequent of the corrosion of Stainless Steel (SS304) orthodontic wires. The aim of this study was to evaluate the corrosion resistance of zinc-coated (Zn-coated) SS orthodontic wires. METHODS: Zinc coating was applied on SS wires by PVD method. Electrochemical impedance spectroscopy (EIS), Potentiodynamic polarization tests and Tafel analysis methods were used to predict the corrosion behavior of Zn-coated and uncoated SS wires in both neutral and acidic environments. RESULTS: The values of Ecorr ,icorr and Rct ,which were the electrochemical corrosion characteristics, reported better corrosion behavior of Zn-coated SS wires against uncoated ones in both artificial saliva and fluoride-containing environments. Experimental results of the Tafel plot analyses were consistent with that of electrochemical impedance spectroscopy analyses for both biological solutions. CONCLUSION: Applying Zn coating on bare SS orthodontic wire by PVD method might increase the corrosion resistance of the underlying stainless-steel substrate.


Asunto(s)
Espectroscopía Dieléctrica , Ensayo de Materiales , Alambres para Ortodoncia , Saliva Artificial , Acero Inoxidable , Zinc , Corrosión , Acero Inoxidable/química , Zinc/química , Saliva Artificial/química , Aleaciones Dentales/química , Materiales Biocompatibles Revestidos/química , Fluoruros/química , Concentración de Iones de Hidrógeno , Humanos , Propiedades de Superficie , Potenciometría
2.
BMC Oral Health ; 24(1): 564, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745154

RESUMEN

BACKGROUND: Alterations in the mechanical properties of the materials utilized in orthodontic appliances could affect the working properties of the appliances, thereby affecting clinical progress and outcome. Numerous studies have confirmed the correlation between alloy corrosion and raised surface roughness, which has a direct impact on the working characteristics of orthodontic archwires. METHODS: Thirty nickel-titanium (NiTi) orthodontic archwires were utilized in this study. Patients were randomly selected and allocated into three groups according to the randomization plan; (The control group): subjects practiced regular oral hygiene; (The fluoride group): subjects used fluoride for intensive prophylaxis; (The chlorhexidine group): subjects used chlorhexidine. Representative samples were evaluated by SEM, and then SEM images with high resolution were examined using Image J software to determine the surface roughness and obtain the results for further statistical analysis. RESULTS: Our findings indicated a significant difference was found between the three groups regarding the anterior and posterior parts between the control and the two other groups and a non-significant difference between NaF and CHX groups. Overall, the p-value for group comparisons was 0.000 for both parts, indicating a highly significant difference especially between the control and NaF groups. CONCLUSION: Mouthwashes containing sodium fluoride demonstrated more significant surface alterations than the control and CHX groups and should be prescribed in accordance with orthodontic materials to reduce side effects.


Asunto(s)
Aleaciones , Clorhexidina , Aleaciones Dentales , Microscopía Electrónica de Rastreo , Níquel , Alambres para Ortodoncia , Fluoruro de Sodio , Propiedades de Superficie , Humanos , Fluoruro de Sodio/uso terapéutico , Clorhexidina/uso terapéutico , Corrosión , Aleaciones Dentales/química , Níquel/química , Titanio/química , Cariostáticos/uso terapéutico , Cariostáticos/química , Masculino , Femenino , Adulto Joven , Antisépticos Bucales/uso terapéutico , Antisépticos Bucales/química , Procesamiento de Imagen Asistido por Computador/métodos , Adolescente , Adulto , Higiene Bucal
3.
Luminescence ; 39(5): e4753, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38698700

RESUMEN

A simple and environmentally friendly method was developed for smart and efficient waterborne polyurethane (PUR) paint. Sugarcane bagasse was recycled into reduced graphene oxide nanosheets (rGONSs). Both lanthanide-doped aluminate nanoparticles (LAN; photoluminescent agent, 7-9 nm) and rGONSs (reinforcement agent) were integrated into a waterborne polyurethane to produce a novel photoluminescent, hydrophobic, and anticorrosive nanocomposite coating. Using ferrocene-based oxidation under masked circumstances, graphene oxide nanosheets were produced from sugarcane bagasse. The oxidized semicarbazide (SCB) nanostructures were integrated into polyurethane coatings as a drying, anticorrosion, and crosslinking agent. Polyurethane coatings with varying amounts of phosphor pigment were prepared and subsequently applied to mild steel. The produced paints (LAN/rGONSs@PUR) were tested for their hydrophobicity, hardness, and scratch resistance. Commission Internationale de l'éclairage (CIE) Laboratory parameters and photoluminescence analysis established the opacity and colourimetric properties of the nanocomposite coatings. When excited at 365 nm, the luminescent transparent paints emitted a strong greenish light at 517 nm. The anticorrosion characteristics of the coated steel were investigated. The phosphor-containing (11% w/w) polyurethane coatings displayed the most pronounced anticorrosion capability and long-persistent luminosity. The prepared waterborne polyurethane paints were very photostable and durable.


Asunto(s)
Grafito , Interacciones Hidrofóbicas e Hidrofílicas , Nanocompuestos , Pintura , Poliuretanos , Poliuretanos/química , Grafito/química , Nanocompuestos/química , Luminiscencia , Corrosión , Tecnología Química Verde
4.
ACS Biomater Sci Eng ; 10(5): 3438-3453, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38564666

RESUMEN

Despite being a weaker metal, zinc has become an increasingly popular candidate for biodegradable implant applications due to its suitable corrosion rate and biocompatibility. Previous studies have experimented with various alloy elements to improve the overall mechanical performance of pure Zn without compromising the corrosion performance and biocompatibility; however, the thermal stability of biodegradable Zn alloys has not been widely studied. In this study, TiC nanoparticles were introduced for the first time to a Zn-Al-Cu system. After hot rolling, TiC nanoparticles were uniformly distributed in the Zn matrix and effectively enabled phase control during solidification. The Zn-Cu phase, which was elongated and sharp in the reference alloy, became globular in the nanocomposite. The strength of the alloy, after introducing TiC nanoparticles, increased by 31% from 259.7 to 340.3 MPa, while its ductility remained high at 49.2% elongation to failure. Fatigue performance also improved greatly by adding TiC nanoparticles, increasing the fatigue limit by 47.6% from 44.7 to 66 MPa. Furthermore, TiC nanoparticles displayed excellent phase control capability during body-temperature aging. Without TiC restriction, Zn-Cu phases evolved into dendritic morphologies, and the Al-rich eutectic grew thicker at grain boundaries. However, both Zn-Cu and Al-rich eutectic phases remained relatively unchanged in shape and size in the nanocomposite. A combination of exceptional tensile properties, improved fatigue performance, better long-term stability with a suitable corrosion rate, and excellent biocompatibility makes this new Zn-Al-Cu-TiC material a promising candidate for biodegradable stents and other biodegradable applications.


Asunto(s)
Implantes Absorbibles , Cobre , Stents , Zinc , Zinc/química , Zinc/farmacología , Cobre/química , Cobre/farmacología , Aleaciones/química , Humanos , Titanio/química , Titanio/farmacología , Aluminio/química , Aluminio/farmacología , Ensayo de Materiales , Corrosión , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Nanopartículas del Metal/química , Nanopartículas del Metal/uso terapéutico , Nanopartículas/química , Nanocompuestos/química
5.
ACS Biomater Sci Eng ; 10(5): 2880-2893, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38630940

RESUMEN

Cobalt-chromium-molybdenum (CoCrMo) alloys are common wear-exposed biomedical alloys and are manufactured in multiple ways, increasingly using additive manufacturing processes such as laser powder bed fusion (LPBF). Here, we investigate the effect of proteins and the manufacturing process (wrought vs LPBF) and building orientation (LPBF-XY and XZ) on the corrosion, metal release, tribocorrosion, and surface oxide composition by means of electrochemical, mechanical, microscopic, diffractive, and spectroscopic methods. The study was conducted at pH 7.3 in 5 g/L NaCl and 5 mM 2-(N-morpholino) ethanesulfonic acid (MES) buffer, which was found to be necessary to avoid metal phosphate and metal-protein aggregate precipitation. The effect of 10 g/L bovine serum albumin (BSA) and 2.5 g/L fibrinogen (Fbn) was studied. BSA and Fbn strongly enhanced the release of Co, Cr, and Mo and slightly enhanced the corrosion (still in the passive domain) for all CoCrMo alloys and most for LPBF-XZ, followed by LPBF-XY and the wrought CoCrMo. BSA and Fbn, most pronounced when combined, significantly decreased the coefficient of friction due to lubrication, the wear track width and severity of the wear mechanism, and the tribocorrosion for all alloys, with no clear effect of the manufacturing type. The wear track area was significantly more oxidized than the area outside of the wear track. In the reference solution without proteins, a strong Mo oxidation in the wear track surface oxide was indicative of a pH decrease and cell separation of the anodic and cathodic areas. This effect was absent in the presence of the proteins.


Asunto(s)
Rayos Láser , Albúmina Sérica Bovina , Corrosión , Albúmina Sérica Bovina/química , Bovinos , Animales , Polvos , Fibrinógeno/química , Ensayo de Materiales , Cobalto/química , Propiedades de Superficie , Cromo/química , Vitalio/química
6.
Colloids Surf B Biointerfaces ; 238: 113880, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38581836

RESUMEN

In the field of orthopedics, it's crucial to effectively slow down the degradation rate of Mg alloys. This study aims to improve the degradation behavior of Mg-Zn-Ca alloys by electrodepositing fluorohydroxyapatite (FHA). We investigated the microstructure and bond strength of the deposition, as well as degradation and cellular reactions. After 15-30 days of degradation in Hanks solution, FHA deposited alloys showed enhanced stability and less pH change. The strong interfacial bond between FHA and the Mg-Zn-Ca substrate was verified through scratch tests (Critical loads: 10.73 ± 0.014 N in Mg-Zn-0.5Ca alloys). Cellular studies demonstrated that FHA-coated alloys exhibited good cytocompatibility and promoted the growth of MC3T3-E1 cells. Further tests showed FHA-coated alloys owed improved early bone mineralization and osteogenic properties, especially in Mg-Zn-0.5Ca. This research highlighted the potential of FHA-coated Mg-Zn-0.5Ca alloys in orthopedics applications.


Asunto(s)
Aleaciones , Calcio , Magnesio , Zinc , Aleaciones/química , Aleaciones/farmacología , Corrosión , Animales , Zinc/química , Zinc/farmacología , Magnesio/química , Ratones , Calcio/química , Calcio/metabolismo , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Propiedades de Superficie , Ensayo de Materiales , Proliferación Celular/efectos de los fármacos , Hidroxiapatitas/química , Línea Celular , Durapatita/química , Durapatita/farmacología
7.
PLoS One ; 19(4): e0300440, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38598505

RESUMEN

The automatic detection of the degree of surface corrosion on metal structures is of significant importance for assessing structural damage and safety. To effectively identify the corrosion status on the surface of coastal metal facilities, this study proposed a CBG-YOLOv5s model for metal surface corrosion detection, based on the YOLOv5s model. Firstly, we integrated the Convolutional Block Attention Module (CBAM) into the C3 module and developed the C3CBAM module. This module effectively enhanced the channel and spatial attention capabilities of the feature map, thereby improving the feature representation. Second, we introduced a multi-scale feature fusion concept in the feature fusion part of the model and added a small target detection layer to improve small target detection. Finally, we designed a lighter C3Ghost module, which reduced the number of parameters and the computational load of the model, thereby improving the running speed of the model. In addition, to verify the effectiveness of our method, we constructed a dataset containing 6000 typical images of metal surface corrosion and conducted extensive experiments on this dataset. The results showed that compared to the YOLOv5s model and several other commonly used object detection models, our method achieved superior performance in terms of detection accuracy and speed.


Asunto(s)
Artículos Domésticos , Reconocimiento en Psicología , Corrosión , Metales
8.
ACS Appl Mater Interfaces ; 16(15): 18503-18521, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38570902

RESUMEN

Biomaterials can induce an inflammatory response in surrounding tissues after implantation, generating and releasing reactive oxygen species (ROS), such as hydrogen peroxide (H2O2). The excessive accumulation of ROS may create a microenvironment with high levels of oxidative stress (OS), which subsequently accelerates the degradation of the passive film on the surface of titanium (Ti) alloys and affects their biological activity. The immunomodulatory role of macrophages in biomaterial osteogenesis under OS is unknown. This study aimed to explore the corrosion behavior and bone formation of Ti implants under an OS microenvironment. In this study, the corrosion resistance and osteoinduction capabilities in normal and OS conditions of the Ti-24Nb-4Zr-8Sn (wt %, Ti2448) were assessed. Electrochemical impedance spectroscopy analysis indicated that the Ti2448 alloy exhibited superior corrosion resistance on exposure to excessive ROS compared to the Ti-6Al-4V (TC4) alloy. This can be attributed to the formation of the TiO2 and Nb2O5 passive films, which mitigated the adverse effects of OS. In vitro MC3T3-E1 cell experiments revealed that the Ti2448 alloy exhibited good biocompatibility in the OS microenvironment, whereas the osteogenic differentiation level was comparable to that of the TC4 alloy. The Ti2448 alloy significantly alleviates intercellular ROS levels, inducing a higher proportion of M2 phenotypes (52.7%) under OS. Ti2448 alloy significantly promoted the expression of the anti-inflammatory cytokine, interleukin 10 (IL-10), and osteoblast-related cytokines, bone morphogenetic protein 2 (BMP-2), which relatively increased by 26.9 and 31.4%, respectively, compared to TC4 alloy. The Ti2448 alloy provides a favorable osteoimmune environment and significantly promotes the proliferation and differentiation of osteoblasts in vitro compared to the TC4 alloy. Ultimately, the Ti2448 alloy demonstrated excellent corrosion resistance and immunomodulatory properties in an OS microenvironment, providing valuable insights into potential clinical applications as implants to repair bone tissue defects.


Asunto(s)
Osteogénesis , Titanio , Corrosión , Especies Reactivas de Oxígeno , Peróxido de Hidrógeno , Materiales Biocompatibles , Aleaciones/química , Estrés Oxidativo , Propiedades de Superficie , Ensayo de Materiales
9.
J Mech Behav Biomed Mater ; 154: 106510, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38593720

RESUMEN

Stress corrosion cracking (SCC) can be a crucial problem in applying rare earth (RE) Magnesium alloys in environments where mechanical loads and electrochemical driven degradation processes interact. It has been proven already that the SCC behavior is associated with microstructural features, compositions, loading conditions, and corrosive media, especially in-vivo. However, it is still unclear when and how mechanisms acting on multiple scales and respective system descriptors predictable contribute to SCC for the wide set of existing Mg alloys. In the present work, suitable literature data along SCC of Mg alloys has been analyzed to enable the development of a reliable SCC model for MgGd binary alloys. Pearson correlation coefficient and linear fitting are utilized to describe the contribution of selected parameters to corrosion and mechanical properties. Based on our data analysis, a parameter ranking is obtained, providing information on the SCC impact with regard to ultimate tensile strength (UTS) and fracture elongation of respective materials. According to the analyzed data, SCC susceptibility can be grouped and mapped onto Ashby type diagrams for UTS and elongation of respective base materials tested in air and in corrosive media. The analysis reveals the effect of secondary phase content as a crucial materials descriptor for our analyzed materials and enables better understanding towards SCC model development for Mg-5Gd alloy based implant.


Asunto(s)
Aleaciones , Cáusticos , Ensayo de Materiales , Aleaciones/química , Corrosión , Análisis de Datos , Materiales Biocompatibles/química
10.
J Biomater Appl ; 38(10): 1100-1117, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38580320

RESUMEN

The surface topological features of bioimplants are among the key indicators for bone tissue replacement because they directly affect cell morphology, adhesion, proliferation, and differentiation. In this study, we investigated the physical, electrochemical, and biological responses of sandblasted titanium (SB-Ti) surfaces with pore geometries fabricated using a plasma electrolytic oxidation (PEO) process. The PEO treatment was conducted at an applied voltage of 280 V in a solution bath consisting of 0.15 mol L-1 calcium acetate monohydrate and 0.02 mol L-1 calcium glycerophosphate for 3 min. The surface chemistry, wettability, mechanical properties and corrosion behavior of PEO-treated sandblasted Ti implants using hydroxyapatite particles (PEO-SB-Ti) were improved with the distribution of calcium phosphorous porous oxide layers, and showed a homogeneous and hierarchically porous surface with clusters of nanopores in a bath containing calcium acetate monohydrate and calcium glycerophosphate. To demonstrate the efficacy of PEO-SB-Ti, we investigated whether the implant affects biological responses. The proposed PEO-SB-Ti were evaluated with the aim of obtaining a multifunctional bone replacement model that could efficiently induce osteogenic differentiation as well as antibacterial activities. These physical and biological responses suggest that the PEO-SB-Ti may have a great potential for use an artificial bone replacement compared to that of the controls.


Asunto(s)
Durapatita , Oxidación-Reducción , Propiedades de Superficie , Titanio , Titanio/química , Porosidad , Durapatita/química , Tornillos Óseos , Animales , Humectabilidad , Ensayo de Materiales , Osteogénesis/efectos de los fármacos , Electrólisis , Gases em Plasma/química , Diferenciación Celular/efectos de los fármacos , Corrosión , Materiales Biocompatibles/química , Osteoblastos/citología , Ratones
11.
PLoS One ; 19(4): e0298266, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38573921

RESUMEN

A mechanical device inspired by the pistol shrimp snapper claw was developed. This technology features a claw characterized by a periodic opening/closing motion, at a controlled frequency, capable of producing oscillating flows at transitional Reynolds numbers. An innovative method was also proposed for determining the corrosion rate of carbon steel samples under oscillating acidic streams (aqueous solution of HCl). By employing very-thin carbon steel specimens (25 µm thickness), with one side coated with Zn and not exposed to the stream, it became possible to electrochemically sense the Zn surface once the steel sample was perforated, thus providing the average dissolution rate into the most relevant pit on the steel surface. Furthermore, a laser light positioned beneath the metallic sample, along with a camera programmed to periodically capture images of the steel surface, facilitated the accurate counting of the number of newly formed pits. The system consisting of the thin steel sample and the Zn coating can be seen as a type of corrosion sensor. Furthermore, the proposed laser illumination method allows corroborating the electrochemical detection of pits and also establishing their location. The techniques crafted in this study pave the way for developing alternative corrosion sensors that boast appealing attributes: affordability, compactness, and acceptable accuracy to detect in time and space localized damage.


Asunto(s)
Carbono , Acero , Carbono/química , Acero/química , Corrosión , Ríos , Ácidos/química
12.
Acta Biomater ; 180: 171-182, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38570108

RESUMEN

Metallic bioresorbable orthopaedic implants based on magnesium, iron and zinc-based alloys that provide rigid internal fixation without foreign-body complications associated with permanent implants have great potential as next-generation orthopaedic devices. Magnesium (Mg) based alloys exhibit excellent biocompatibility. However, the mechanical performance of such implants for orthopaedic applications is contingent on limiting the rate of corrosion in vivo throughout the bone healing process. Additionally, the surgical procedure for the implantation of internal bone fixation devices may impart plastic deformation to the device, potentially altering the corrosion rate of the device. The primary objective of this study was to develop a computer-based model for predicting the in vivo corrosion behaviour of implants manufactured from a Mg-1Zn-0.25Ca ternary alloy (ZX10). The proposed corrosion model was calibrated with an extensive range of mechanical and in vitro corrosion testing. Finally, the model was validated by comparing the in vivo corrosion performance of the implants during preliminary animal testing with the corrosion performance predicted by the model. The proposed model accurately predicts the in vitro corrosion rate, while overestimating the in vivo corrosion rate of ZX10 implants. Overall, the model provides a "first-line of design" for the development of new bioresorbable Mg-based orthopaedic devices. STATEMENT OF SIGNIFICANCE: Biodegradable metallic orthopaedic implant devices have emerged as a potential alternative to permanent implants, although successful adoption is contingent on achieving an acceptable degradation profile. A reliable computational method for accurately estimating the rate of biodegradation in vivo would greatly accelerate the development of resorbable orthopaedic implants by highlighting the potential risk of premature implant failure at an early stage of the device development. Phenomenological corrosion modelling approach is a promising computational tool for predicting the biodegradation of implants. However, the validity of the models for predicting the in vivo biodegradation of Mg alloys is yet to be determined. Present study investigates the validity of the phenomenological modelling approach for simulating the biodegradation of resorbable metallic orthopaedic implants by using a porcine model that targets craniofacial applications.


Asunto(s)
Implantes Absorbibles , Magnesio , Corrosión , Magnesio/química , Animales , Calibración , Aleaciones/química , Ensayo de Materiales
13.
Acta Biomater ; 180: 183-196, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38604465

RESUMEN

The utilization of biodegradable magnesium (Mg) alloys in the fabrication of temporary non-vascular stents is an innovative trend in biomedical engineering. However, the heterogeneous degradation profiles of these biomaterials, together with potential bacterial colonization that could precipitate infectious or stenotic complications, are critical obstacles precluding their widespread clinical application. In pursuit of overcoming these limitations, this study applies the principles of biomimicry, particularly the hydrophobic and anti-fouling characteristics of lotus leaves, to pioneer the creation of nanocomposite coatings. These coatings integrate poly-trimethylene carbonate (PTMC) with covalent organic frameworks (COFs), to modify the stent's surface property. The strategic design of the coating's topography, porosity, and self-polishing capabilities collectively aims to decelerate degradation processes and minimize biological adhesion. The protective qualities of the coatings were substantiated through rigorous testing in both in vitro dynamic bile tests and in vivo New Zealand rabbit choledochal models. Empirical findings from these trials confirmed that the implementation of COF-based nanocomposite coatings robustly fortifies Mg implantations, conferring heightened resistance to both biocorrosion and biofouling as well as improved biocompatibility within bodily environments. The outcomes of this research elucidate a comprehensive framework for the multifaceted strategies against stent corrosion and fouling, thereby charting a visionary pathway toward the systematic conception of a new class of reliable COF-derived surface modifications poised to amplify the efficacy of Mg-based stents. STATEMENT OF SIGNIFICANCE: Biodegradable magnesium (Mg) alloys are widely utilized in temporary stents, though their rapid degradation and susceptibility to bacterial infection pose significant challenges. Our research has developed a nanocomposite coating inspired by the lotus, integrating poly-trimethylene carbonate with covalent organic frameworks (COF). The coating achieved self-polishing property and optimal surface energy on the Mg substrate, which decelerates stent degradation and reduces biofilm formation. Comprehensive evaluations utilizing dynamic bile simulations and implantation in New Zealand rabbit choledochal models reveal that the coating improves the durability and longevity of the stent. The implications of these findings suggest the potential COF-based Mg alloy stent surface treatments and a leap forward in advancing stent performance and endurance in clinical applications.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles Revestidos , Magnesio , Nanocompuestos , Stents , Animales , Conejos , Magnesio/química , Magnesio/farmacología , Nanocompuestos/química , Corrosión , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Estructuras Metalorgánicas/química , Estructuras Metalorgánicas/farmacología , Incrustaciones Biológicas/prevención & control , Dioxanos/química , Materiales Biomiméticos/química , Materiales Biomiméticos/farmacología , Polímeros/química , Polímeros/farmacología , Aleaciones/química , Aleaciones/farmacología
14.
Int J Biol Macromol ; 267(Pt 2): 131429, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38583828

RESUMEN

Herein, a novel chitosan Schiff base (CS-FGA) as a sustainable corrosion inhibitor has been successfully synthesized via a simple amidation reaction by using an imidazolium zwitterion and chitosan (CS). The corrosion inhibition property of CS-FGA for mild steel (MS) in a 1.0 M HCl solution was studied by various electrochemical tests and physical characterization methods. The findings indicate that the maximum inhibition efficiency of CS-FGA as a mixed-type inhibitor for MS in 1.0 M HCl solution with 400 mg L-1 reaches 97.6 %, much much higher than the CS and the recently reported chitosan-based inhibitors. Scanning electron microscopy (SEM), atomic force microscopy (AFM), and water contact angle (WCA) results reveal that the CS-FGA molecules firmly adsorb on the MS surface to form a protective layer. The adsorption of CS-FGA on the MS surface belongs to the Langmuir adsorption isotherm containing both the physisorption and chemisorption. According to the X-ray photoelectron spectroscopy (XPS) and UV-vis spectrum, FeN bonds presented on the MS surface further prove the chemisorption between CS-FGA and Fe to generate the stable protective layer. Additionally, theoretical calculations from quantum chemical calculation (DFT) and molecular simulations (MD) were performed to reveal the inhibition mechanism of CS-FGA.


Asunto(s)
Quitosano , Ácido Clorhídrico , Acero , Quitosano/química , Acero/química , Corrosión , Ácido Clorhídrico/química , Adsorción , Bases de Schiff/química , Soluciones , Espectroscopía de Fotoelectrones , Propiedades de Superficie
15.
Biotechnol J ; 19(3): e2300464, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38509814

RESUMEN

The present study evaluates the corrosion behavior of poly[xylitol-(1,12-dodecanedioate)](PXDD)-HA coated porous iron (PXDD140/HA-Fe) and its cell-material interaction aimed for temporary bone scaffold applications. The physicochemical analyses show that the addition of 20 wt.% HA into the PXDD polymers leads to a higher crystallinity and lower surface roughness. The corrosion assessments of the PXDD140/HA-Fe evaluated by electrochemical methods and surface chemistry analysis indicate that HA decelerates Fe corrosion due to a lower hydrolysis rate following lower PXDD content and being more crystalline. The cell viability and cell death mode evaluations of the PXDD140/HA-Fe exhibit favorable biocompatibility as compared to bare Fe and PXDD-Fe scaffolds owing to HA's bioactive properties. Thus, the PXDD140/HA-Fe scaffolds possess the potential to be used as a biodegradable bone implant.


Asunto(s)
Materiales Biocompatibles Revestidos , Xilitol , Ensayo de Materiales , Materiales Biocompatibles Revestidos/química , Corrosión , Porosidad , Hierro , Durapatita/química
16.
Sci Total Environ ; 923: 171384, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432383

RESUMEN

Some methanogens are electrotrophic bio-corroding microbes that can acquire electrons from solid surfaces including metals. In the laboratory, pure cultures of methanogenic cells oxidize iron-based materials including carbon steel, stainless steel, and Fe0. For buried or immersed pipelines or other metallic structures, methanogens are often major components of corroding biofilms with complex interspecies relationships. Models explaining how these microbes acquire electrons from solid donors are multifaceted and include electron transfer via redox mediators such as H2 or by direct contact through membrane proteins. Understanding the electron uptake (EU) routes employed by corroding methanogens is essential to develop efficient strategies for corrosion prevention. It is also beneficial for the development of bioenergy applications relying on methanogenic EU from solid donors such as bioelectromethanogenesis, hybrid photosynthesis, and the acceleration of anaerobic digestion with electroconductive particles. Many methanogenic species carrying out biocorrosion are the same ones forming the extensive abiotic-biological interfaces at the core of these bio-applications. This review will discuss the interactions between corrosive methanogens and metals and how the EU capability of these microbes can be harnessed for different sustainable biotechnologies.


Asunto(s)
Dióxido de Carbono , Electrones , Dióxido de Carbono/química , Metales , Oxidación-Reducción , Transporte de Electrón , Corrosión
17.
Appl Microbiol Biotechnol ; 108(1): 253, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38441693

RESUMEN

The synergistic corrosion effect of acid-producing bacteria (APB) and magnetite on carbon steel corrosion was assessed using two different microbial consortia. A synergistic corrosion effect was observed exclusively with Consortium 2, which was composed of Enterobacter sp., Pseudomonas sp., and Tepidibacillus sp. When Consortium 2 was accompanied by magnetite, uniform corrosion and pitting rates were one-time higher (0.094 mm/year and 0.777 mm/year, respectively) than the sum of the individual corrosion rates promoted by the consortium and deposit separately (0.084 and 0.648 mm/year, respectively). The synergistic corrosion effect observed exclusively with Consortium 2 is attributed to its microbial community structure. Consortium 2 exhibited higher microbial diversity that benefited the metabolic status of the community. Although both consortia induced acidification of the test solution and metal surface through glucose fermentation, heightened activity levels of Consortium 2, along with increased surface roughness caused by magnetite, contributed to the distinct synergistic corrosion effect observed with Consortium 2 and magnetite. KEY POINTS: • APB and magnetite have a synergistic corrosion effect on carbon steel. • The microbial composition of APB consortia drives the synergistic corrosion effect. • Magnetite increases carbon steel surface roughness.


Asunto(s)
Óxido Ferrosoférrico , Microbiota , Corrosión , Carbono , Acero
18.
Environ Sci Technol ; 58(12): 5606-5615, 2024 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-38470122

RESUMEN

Gaps in the United States Environmental Protection Agency (US EPA) Lead and Copper Rule (LCR) leave some consumers and their pets vulnerable to high cuprosolvency in drinking water. This study seeks to help proactive utilities who wish to mitigate cuprosolvency problems through the addition of orthophosphate corrosion inhibitors. The minimum doses of orthophosphate necessary to achieve acceptable cuprosolvency in relatively new copper pipe were estimated as a function of alkalinity via linear regressions for the 90th, 95th, and 100th percentile copper tube segments (R2 > 0.98, n = 4). Orthophosphate was very effective at reducing cuprosolvency in the short term but, in some cases, resulted in higher long-term copper concentrations than the corresponding condition without orthophosphate. Alternatives to predicting "long-term" results for copper tubes using simpler bench tests starting with fresh Cu(OH)2 solids showed promise but would require further vetting to overcome limitations such as maintaining water chemistry and orthophosphate residuals and to ensure comparability to results using copper tube.


Asunto(s)
Agua Potable , Contaminantes Químicos del Agua , Estados Unidos , Cobre/análisis , Fosfatos , Abastecimiento de Agua , Corrosión
19.
J Mater Sci Mater Med ; 35(1): 18, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38526654

RESUMEN

Surface modification of titanium and its alloys has been seriously considered by researchers to improve their biological behaviors, in the past few decades. In present research, hydroxyapatite (HA) based composite coatings with different concentrations of 0, 2, 4, and 6 wt% of silver (Ag) nanoparticles were electrophoretically deposited (EPD) on anodized and non-anodized Ti6Al4V, using a direct current at a voltage of 30 V for 10 min at room temperature. The specimens were then characterized by means of X-ray diffraction (XRD) analysis, Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) equipped with energy dispersive spectroscopy (EDS). The cell adhesion images and cell viability results showed that HA-Ag composite coatings significantly promoted the biocompatibility of samples compared with the non-anodized and anodized Ti6Al4V. The viabilities of Mg-63 cells on HA-4%Ag coating and bi-layer coating (HA-4%Ag on anodized specimen) were approximately 91% and they were considered as the best coatings in term of biocompatibility. On the other hand, the antibacterial assessments demonstrated that HA-6%Ag coating had the best antibacterial performance compared with other samples. Furthermore, Tafel polarization curves indicated that corrosion resistance of the bi-layer coating was higher than those of the other specimens. The polarization resistance of this coating was about 7 times more than that of theTi6Al4V alloy.


Asunto(s)
Durapatita , Nanopartículas del Metal , Durapatita/química , Titanio/química , Plata , Espectroscopía Infrarroja por Transformada de Fourier , Materiales Biocompatibles Revestidos/química , Corrosión , Difracción de Rayos X , Aleaciones/química , Antibacterianos
20.
Sci Total Environ ; 925: 171763, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38494030

RESUMEN

Microbial biofilms are behind microbiologically influenced corrosion (MIC). Sessile cells in biofilms are many times more concentrated volumetrically than planktonic cells in the bulk fluids, thus providing locally high concentrations of chemicals. More importantly, "electroactive" sessile cells in biofilms are capable of utilizing extracellularly supplied electrons (e.g., from elemental Fe) for intracellular reduction of an oxidant such as sulfate in energy metabolism. MIC directly caused by anaerobic biofilms is classified into two main types based on their mechanisms: extracellular electron transfer MIC (EET-MIC) and metabolite MIC (M-MIC). Sulfate-reducing bacteria (SRB) are notorious for their corrosivity. They can cause EET-MIC in carbon steel, but they can also secrete biogenic H2S to corrode other metals such as Cu directly via M-MIC. This study investigated the use of conductive magnetic nanowires as electron mediators to accelerate and thus identify EET-MIC of C1020 by Desulfovibrio vulgaris. The presence of 40 ppm (w/w) nanowires in ATCC 1249 culture medium at 37 °C resulted in 45 % higher weight loss and 57 % deeper corrosion pits after 7-day incubation. Electrochemical tests using linear polarization resistance and potentiodynamic polarization supported the weight loss data trend. These findings suggest that conductive magnetic nanowires can be employed to identify EET-MIC. The use of insoluble 2 µm long nanowires proved that the extracellular section of the electron transfer process is a bottleneck in SRB MIC of carbon steel.


Asunto(s)
Desulfovibrio vulgaris , Desulfovibrio , Nanocables , Humanos , Acero , Electrones , Carbono/metabolismo , Biopelículas , Desulfovibrio/metabolismo , Corrosión , Sulfatos/metabolismo , Pérdida de Peso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...